Midea Air Handling Unit
Ceiling suspended
1000CFM ---9000CFM
Floor mounted
3000CFM ---25000CFM
Vertical mounted
3000CFM ---25000CFM
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 3/203
General
With years of design and manufacturing experience, Midea carried out the new 2nd
generation Air Handling Unit (MKSII Series) with a series of improvements and
innovations to meet market demand. As comfort air-conditioning, it can be widely used in
hotels, theaters, shopping malls, office buildings, schools and other places; as for
industrial use air conditioning, it can also meet the electronics, chemical, medical,
pharmaceutical, cigarettes, food, light industry and other industries needs.
The standard MKSII Series AHU can be divided into 3 types which are suspended,
horizontal and vertical types. The air volume is from 2000 m3/h to 40,000 m3/h (1000 to
25,000CFM).
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 4/204
Features
Cold-bridge Free Design
Both the framework and panels are designed to be isolated. And the cavity of the framework and
panels are filled with high-density polyurethane foam (density ≥ 50kg/m3
) to cut off cold bridge
completely, which can effectively prevent cooling capacity loss and external condensate.
Multiple-seal to Prevent Air Leakage
Units using multiple “ladder-style” structure, both inside and outside ladder are with closed
measures. Coupled with the negative pressure design, can ensure that the units of air leakage
rate is a low air leakage rate ≤ 0.29%, only the provisions of the national standard 1 / 10, more no
danger of water leakage.
Lower Noise Running
Famous-brand fan is in use. The professional selection software makes sure the optimum
working point and outlet velocity to guarantee the smooth & low noise air flow in the duct.
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 5/205
More compact size, Space saving
The dimensions of the units are optimized and the performance is maintained. The units with
more compact size save the installation space rapidly.
Optimized water pass, Higher heat transferring efficiency
The coil uses windowed high-quality aluminum fin staggered arrangement, coupled with a wide
range of flow path design optimization, which is taking into account the higher heat transferring
efficiency and lower liquid side resistance.
Better appearance, Anti-corrosion and anti-damage
Fillet corner, beautiful color steel with protection film that can against rust, corrosion and damage
while transportation.
Assembled structure, Easier maintenance
Assembled structure is easy for assembly and maintenance at site, also it’s suitable for CKD
transportation.
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 6/206
How to Read the Model No.?
MKSII 080 D A — Z
Connection Direction: Z—Left,Y—Right
Rows: A — 4 Rows, B — 6 Rows
C — Other, 2 Rows etc.
Type: D — Ceiling Suspended
W — Horizontal
L — Vertical
Nominal Air Volume: ( 80×100 m3 /h)
Midea 2nd generation AHU
Standard Power Source is “415V-3¢-50Hz”
Pipe Connection Direction
Face the air inlet (along the air flow direction),
If the connection pipes and maintenance access is left side, then the unit is left-connection unit,
Otherwise is the right-connection unit.
Air inlet
Air outlet
It is
left-connection
unit
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 7/207
SPECIFICATIONS Ceiling Suspended (Recycling Air)
Chilled Water
Model No.NominalAirVolume
CoolingCapacit
y
HeatingCapacity Flow
rate
Resist
ance
STD
ESP
STD
Motor
Powe
r
Noise N.W.
ESP
Rang
e
Dimensions
L×W×H
MKSII-D m3 /h kW kWL/s kPa Pa kW dB(A) kg Pa mm
4R 12.1 14.9 0.58 10.4 56.2 98020
6R2000
14.2 18.5 0.68 12.5120 0.37
57.1 110
80~
200900*850*525
4R 17.1 20.5 0.82 15.2 57.4 122030
6R3000
20.1 26.5 0.96 20.4130 0.37
57.5 140
80~
2001010*970*555
4R 23.1 27.7 1.10 12.6 58.2 162040
6R4000
28.4 35.2 1.36 18.5130 0.55
60.1 173
80~
300
1010*1300*555
4R 30.5 36.8 1.46 14.4 59.5 196050
6R5000
37.1 43.9 1.77 15.2130 1.1
61.5 218
80~
300
1010*1360*605
4R 34.8 43.6 1.66 21.1 60.2 215060
6R6000
42.8 52.5 2.05 25.8170 1.1
61.5 242
100~
350
1010*1550*605
4R 42.9 51.5 2.05 25.0 62.1 232070
6R7000
50.5 60.6 2.42 27.4180 1.5
63.5 260
100~
350
1010*1600*680
4R 49.2 60.1 2.35 28.3 63.4 251080
6R8000
60.2 72.2 2.88 30.4180 1.5
63.5 275
100~
350
1050*1800*680
4R 58.5 70.2 2.80 27.5 63.5 310100
6R10000
71.5 84.6 3.42 32.5190 2.2
65.2 340
100~
400
1100*1900*785
4R 70.7 84.8 3.38 34.5 65.5 335120
6R12000
89.5 108.6 4.28 38.6210 2.2
67.1 370
100~
450
1100*1950*885
4R 89.2 111.0 4.27 21.4 66.4 402150
6R15000
112.5 138.9 5.38 23.5260 3.0
68.2 445
150~
500
1250*2350*910
Note:
Stand Conditions Entering Air DB(℃) Entering Air WB(℃) Entering Water T(℃) Water ΔT(℃)
Recycling Air Cooling 27 19.5 7 5
Recycling Air Heating 21 — 60 —
◎ Noise data is the average noise pressure of which is got at 1 meter from each surface of the unit, while the unit is
running with the duct connected and without water going though the coil;
◎ If you need a nonstandard ESP, please make a special comment on the order. We recommend you could choose the
ESP within the ESP range showed for the best effect.
◎ If the entering air conditions, entering water conditions or the ESP are different from the standard, the specifications will
change.
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 8/208
SPECIFICATIONS
Ceiling Suspended (Fresh Air)
WaterNominalAir
Volume
CoolingCapacity
HeatingCapacity
Flow rate Resistan
STD
ESP
STD
motor
Powe
Noise N.W.
ESP
Rang
e
Dimensions
L×W×HModel No.
MKSII-D
m3
/h kW kW L/s kPa Pa kW dB(A) kg Pa mm
4R 29.0 34.8 1.39 20.5 56.2 98020
6R2000
36.0 43.2 1.72 30.4120 0.37
57.1 110
80~200
900×850×525
4R 42.3 50.7 2.02 30.6 57.4 122030
6R3000
51.4 61.7 2.46 45.4130 0.37
57.5 140
80~200
1010×970×555
4R 50.3 60.4 2.41 25.3 58.2 162040
6R4000
67.6 81.2 3.23 40.2130 0.55
60.1 173
80~300
1010×1300×555
4R 65.7 78.8 3.14 35.1 59.5 196
0506R
500084.2 101.0 4.03 35.5
130 1.161.5 218
80~300 1010×1360×605
4R 77.8 93.5 3.72 25.4 60.2 215060
6R6000
99.8 119.8 4.77 38.6170 1.1
61.5 242
100~350
1010×1550×605
4R 91.9 110.3 4.40 32.5 62.1 232070
6R7000
115.6 138.7 5.53 40.5180 1.5
63.5 260
100~350
1010×1600×680
4R 107.1 128.5 5.12 42.4 63.4 251080
6R8000
134.4 161.2 6.43 46.4180 1.5
63.5 275
100~350
1050×1800×680
4R 122.8 147.4 5.87 45.3 63.5 310100
6R10000
144.5 173.4 6.91 45.4190 2.2
65.2 340
100~400
1100×1900×785
4R 144.9 173.9 6.93 55.4 65.5 335120
6R12000
183.7 220.5 8.79 55.4210 2.2
67.1 370
100~450
1100×1950×885
4R 185.0 222.0 8.85 50.4 66.4 402150
6R15000
233.3 279.9 11.16 60.6260 3.0
68.2 445
150~500
1250×2350×910
Note:
Stand Conditions Entering Air DB(℃)
Entering Air WB(℃)
Entering Water T(℃)
Water Δ
T(℃)
Fresh Air Cooling 35 28 7 5
Fresh Air Heating 7 — 60 —
◎ Noise data is the average noise pressure of which is got at 1 meter from each surface of the unit, while the unit is running
with the duct connected and without water going though the coil;
◎ If you need a nonstandard ESP, please make a special comment on the order. We recommend you could choose the
ESP within the ESP range showed for the best effect.
◎ If the entering air conditions, entering water conditions or the ESP are different from the standard, the specifications will
change.
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 9/20
Dimensions: Ceiling Suspended
Outline Installation C Air Inlet Air OutlModel
MKSII L W H A B 4R 6RD
E FG J K
M
020D 900 850 525 826 946 66 110 25 416 766 152 292 / 267 2
030D 1010 970 555 936 1066 66 110 25 446 886 127 343 / 306 2
040D 1010 1300 555 936 1396 66 110 25 446 1216 152 343 176 240 2
050D 1010 1360 605 936 1456 66 110 25 496 1276 152 394 176 240 2
060D 1010 1550 605 936 1646 66 110 25 496 1466 127 394 236 306 2
070D 1010 1600 680 969 1696 66 110 50 546 1516 177 444 206 273 2080D 1050 1800 680 1009 1896 66 110 50 546 1716 177 444 256 339 2
100D 1100 1900 785 1059 1996 66 110 50 651 1816 205 546 316 403 3
120D 1100 1950 885 1059 2046 66 110 50 651 1866 205 648 316 403 3
150D 1250 2350 910 1209 2446 104 173 50 776 2266 205 620 286 385 4
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 10/20
SPECIFICATIONS
Horizontal (Recycling Air)
WaterNominalAir
Volume
CoolingCapacity
HeatingCapacity
Flow rate Resistance
STD
ESP
STD
motor
Powe
Noise N.W.
ESP
Rang
e
Dimensions
L×W×HModel No.
MKSII-W
m3 /h kW kW L/s kPa Pa kW dB(A) kg Pa mm
4R 30.5 36.8 1.46 10.5 59.5 205050
6R5000
37.1 43.9 1.77 14.6150 0.75
61.2 221
80~300
1120×1060×780
4R 34.8 43.6 1.66 9.4 60.3 220060
6R6000
42.8 52.5 2.05 12.6180 1.1
61.4 249
100~350
1120×1230×780
4R 49.2 60.1 2.35 18.2 63.1 260080
6R8000
60.2 72.2 2.88 20.5180 1.5
63.5 283
100~350
1150×1370×880
4R 58.5 70.2 2.80 24.4 63.5 318
1006R
1000071.5 84.6 3.42 28.2
250 2.265.2 346
150~350
1200×1650×890
4R 89.2 111.0 4.27 25.4 66.1 405150
6R15000
112.5 138.9 5.38 30.6260 3.0
68.2 4G50
150~500
1200×1940×1155
4R 122.5 150.8 5.86 16.5 70.4 552200
6R20000
145.2 160.7 6.95 21.5310 5.5
71.6 590
150~600
1350×2350×1155
4R 141.5 183.0 6.77 35.1 70.2 610250
6R25000
181.8 218.2 8.70 36.6410 7.5
71.5 645
200~600
1350×2350×1395
4R 198.5 243.0 9.49 34.2 73.3 690300
6R30000
222.0 266.4 10.62 37.1410 11
73.5 730
250~650
1450×2730×1475
4R 216.2 268.2 10.34 29.3 73.8 781350
6R35000
245.8 294.9 11.76 31.4500 2×5.5
74.2 838
250~650
1830×2710×1635
4R 241.5 299.2 11.55 32.2 76.2 1010400
6R40000
264.4 317.2 12.65 39.4550 2×7.5
77.5 1095
300~650
1830×3050×1635
Note:
Stand Conditions Entering Air DB(℃)
Entering Air WB(℃)
Entering Water T(℃)
Water Δ
T(℃)
Fresh Air Cooling 27 19.5 7 5
Fresh Air Heating 21 — 60 —
◎ Noise data is the average noise pressure of which is got at 1 meter from each surface of the unit, while the unit is
running with the duct connected and without water going though the coil;
◎ If you need a nonstandard ESP, please make a special comment on the order. We recommend you could choose the
ESP within the ESP range showed for the best effect.
◎ If the entering air conditions, entering water conditions or the ESP are different from the standard, the specifications
will change.
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 11/2011
SPECIFICATIONS
Horizontal (Fresh Air)
WaterNominalAir
Volume
CoolingCapacity
HeatingCapacity
Flow rate Resistan
STD
ESP
STD
motor
Powe
Noise N.W.ESP
Rang
e
Dimensions
L×W×HModel No.
MKSII-W
m3
/h kW kW L/s kPa Pa kW dB(A) kg Pa mm
4R 65.7 78.8 3.14 30.4 59.5 205050
6R5000
84.2 101.0 4.03 34.4
150 0.75
61.1 221
80~300
1120×1060×780
4R 77.8 93.5 3.72 21.2 60.2 220060
6R6000
99.8 119.8 4.77 22.6180 1.1
61.4 249
100~350
1120×1230×780
4R 107.1 128.5 5.12 28.7 63.0 260080
6R
8000
134.4 161.2 6.43 30.1
180 1.5
63.5 283
100~350
1150×1370×880
4R 122.8 147.4 5.87 25.2 63.2 318100
6R
10000
144.5 173.4 6.91 35.3
250 2.2
65.4 346
150~350
1200×1650×890
4R 185.0 222.0 8.85 62.4 66.3 405150
6R15000
233.3 279.9 11.16 65.3
260 3.0
68.1 450
150~500
1200×1940×1155
4R 269.0 322.8 12.87 40.5 70.5 552200
6R20000
299.9 359.9 14.35 45.2
310 5.5
71.6 590
150~600
1350×2350×1155
4R 329.4 395.24 15.76 75.1 70.5 610250
6R
25000
403.6 484.3 19.31 82.3
410 7.5
71.5 645
200~600
1350×2350×1395
4R 433.4 520.0 20.73 70.4 73.2 690300
6R30000
492.8 591.4 23.57 72.2
410 1173.5 730
250~650
1450×2730×1475
4R 478.3 573.9 22.88 65.2 73.4 781350
6R35000
540.8 640.9 25.87 70.6500 2×5.5
74.3 838
250~650
1830×2710×1635
4R 533.7 640.5 25.53 60.4 76.4 1010400
6R
40000
581.7 698.0 27.82 71.2
550 2×7.5
77.5 1095
300~650
1830×3050×1635
Note:
Stand Conditions Entering Air DB(℃) Entering Air WB(℃) Entering Water T(℃) Water ΔT(℃)
Fresh Air Cooling 35 28 7 5
Fresh Air Heating 7 — 60 —
◎ Noise data is the average noise pressure of which is got at 1 meter from each surface of the unit, while the unit is
running with the duct connected and without water going though the coil;
◎ If you need a nonstandard ESP, please make a special comment on the order. We recommend you could choose the
ESP within the ESP range showed for the best effect.
◎ If the entering air conditions, entering water conditions or the ESP are different from the standard, the specifications
will change.
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 12/20
Dimensions: Horizontal
Outline C Air Inlet Air Outlet Model
MKSII L W H 4R 6RD
E FG J K
M N
050W 1120 1060 780 66 110 40 656 976 104 475 / 317 349
060W 1120 1230 780 66 110 40 656 1146 104 475 / 403 349
080W 1150 1370 880 66 110 40 756 1286 116 576 / 479 412
100W 1200 1650 890 66 110 50 756 1566 116 576 / 479 412
150W 1200 1940 1155 104 173 50 1021 1856 381 840 286 381 412
200W 1350 2350 1155 104 173 50 1021 2266 215 840 335 438 486
250W 1350 2350 1395 104 173 50 1261 2266 445 1080 335 438 486
300W 1450 2730 1475 104 173 50 1341 2646 525 1160 450 565 486
350W 1830 2710 1635 104 173 50 1501 2626 685 1320 788 565 486
400W 1830 3050 1635 104 173 50 1501 2966 685 1320 828 565 486
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 13/20
SPECIFICATIONS Vertical (Recycling Air)
WaterNominalAir
Volume
CoolingCapacity
HeatingCapacity
Flow rateResistan
ce
STD
ESP
STD
motor
PoweNoise N.W.
ESP
Rang
e
Dimensions
L×W×HModel No.
MKSII-L
m3 /h kW kW L/s kPa Pa kW dB(A) kg Pa mm
4R 17.1 20.5 0.82 15.2 57.1 135030
6R
3000
20.1 26.5 0.96 20.1
130 0.55
57.5 160
80~
200
650×1000×1150
4R 23.1 27.7 1.10 12.4 58.2 195040
6R4000
28.4 35.2 1.36 18.5150 0.75
60.3 206
80~300
670×1250×1200
4R 30.5 36.8 1.46 14.4 59.5 225050
6R5000
37.1 43.9 1.77 15.7150 1.1
61.2 242
80~300
750×1150×1440
4R 34.8 43.6 1.66 10.1 60.4 249060
6R6000
42.8 52.5 2.05 17.8190 1.1
61.1 272
80~350
750×1250×1440
4R 49.2 60.1 2.35 23.4 63.2 272080
6R
8000
60.2 72.2 2.88 26.4
190 1.5
63.6 295
100~350
840×1300×1740
4R 58.5 70.2 2.80 30.2 63.5 338100
6R10000
71.5 84.6 3.42 34.6250 2.2
65.4 361
150~350
840×1525×1740
4R 89.2 111.0 4.27 25.1 66.3 450150
6R15000
112.5 138.9 5.38 30.4270 4.0
68.4 485
150~500
860×1930×1880
4R 122.5 150.8 5.86 16.5 70.5 580200
6R20000
145.2 160.7 6.95 21.7320 5.5
71.2 625
150~600
1000×2350×2040
4R 141.5 183.0 6.77 35.7 70.7 645250
6R
25000
181.8 218.2 8.70 36.9
410 7.5
71.3 693
200~600
1000×2500×2200
4R 198.5 243.0 9.49 34.2 73.1 725300
6R30000
222.0 266.4 10.62 37.9410 11
73.5 816
250~650
1000×2780×2300
4R 216.2 268.2 10.34 29.1 73.6 810350
6R35000
245.8 294.9 11.76 31.1500 2*5.5
74.2 921
250~650
1000×3200×2300
4R 241.5 299.2 11.55 36.4 76.2 1050400
6R40000
264.4 317.2 12.65 46.2550 2*7.5
77.5 1180
300~650
1000×3310×2300
Note:
Stand Conditions Entering Air DB(℃) Entering Air WB(℃) Entering Water T(℃) Water ΔT(℃)
Fresh Air Cooling 27 19.5 7 5Fresh Air Heating 21 — 60 —
◎ Noise data is the average noise pressure of which is got at 1 meter from each surface of the unit, while the unit is
running with the duct connected and without water going though the coil;
◎ If you need a nonstandard ESP, please make a special comment on the order. We recommend you could choose the
ESP within the ESP range showed for the best effect.
◎ If the entering air conditions, entering water conditions or the ESP are different from the standard, the specifications
will change.
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 14/2014
SPECIFICATIONS Vertical (Fresh Air)
WaterNominalAir
Volume
CoolingCapacity
HeatingCapacity
Flow rate Resistan
STD
ESP
STD
motor
Powe
Noise N.W.
ESP
Rang
e
Dimensions
L×W×HModel No.
MKSII-L
m3 /h kW kW L/s kPa Pa kW dB(A) kg Pa mm
4R 42.3 50.7 2.02 30.2 57.1 135030
6R
3000
51.4 61.7 2.46 45.3
130 0.55
57.5 160
80~
200
650×1000×1150
4R 50.3 60.4 2.41 25.7 58.4 195040
6R4000
67.6 81.2 3.23 40.8150 0.75
60.3 206
80~300
670×1250×1200
4R 65.7 78.8 3.14 30.2 59.6 225050
6R5000
84.2 101.0 4.03 34.7150 1.1
61.4 242
80~300
750×1150×1440
4R 77.8 93.5 3.72 21.2 60.1 249060
6R6000
99.8 119.8 4.77 22.8190 1.1
61.4 272
80~350
750×1250×1440
4R 107.1 128.5 5.12 28.7 63.4 272080
6R
8000
134.4 161.2 6.43 30.9
190 1.5
63.7 295
100~350
840×1300×1740
4R 122.8 147.4 5.87 25.8 63.6 338100
6R10000
144.5 173.4 6.91 35.7250 2.2
65.3 361
150~350
840×1525×1740
4R 185.0 222.0 8.85 62.4 66.4 450150
6R15000
233.3 279.9 11.16 65.1270 4.0
68.2 485
150~500
860×1930×1880
4R 269.0 322.8 12.87 40.5 70.4 580200
6R20000
299.9 359.9 14.35 45.9320 5.5
71.7 625
150~600
1000×2350×2040
4R 329.4 395.2 15.76 75.2 70.4 645250
6R
25000
403.6 484.3 19.31 82.6
410 7.5
71.8 693
200~600
1000×2500×2200
4R 433.4 520.0 20.73 70.4 73.1 725300
6R30000
492.8 591.4 23.57 72.2410 11
73.5 816
250~650
1000×2780×2300
4R 478.3 573.9 22.88 65.8 73.6 810350
6R35000
540.8 640.9 25.87 70.1500 2*5.5
74.4 921
250~650
1000×3200×2300
4R 533.7 640.5 25.53 60.7 76.2 1050400
6R40000
581.7 698.0 27.82 71.9550 2*7.5
77.5 1180
300~650
1000×3310×2300
Note:
Stand Conditions Entering Air DB(℃) Entering Air WB(℃) Entering Water T(℃) Water ΔT(℃)
Fresh Air Cooling 35 28 7 5Fresh Air Heating 7 — 60 —
◎ Noise data is the average noise pressure of which is got at 1 meter from each surface of the unit, while the unit is
running with the duct connected and without water going though the coil;
◎ If you need a nonstandard ESP, please make a special comment on the order. We recommend you could choose the
ESP within the ESP range showed for the best effect.
◎ If the entering air conditions, entering water conditions or the ESP are different from the standard, the specifications
will change.
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 15/20
Dimensions: Vertical Type
Outline Air Outlet Air Inlet Pipe XModelMKSII
L W HG
A B E C D 4R 6R
030L 650 1000 1150 60 270 306 / 480 916 DN40 DN40
040L 670 1250 1200 60 297 339 / 480 1166 DN40 DN40
050L 750 1150 1440 60 349 403 / 683 1066 DN40 DN50
060L 750 1280 1440 60 349 403 / 683 1196 DN50 DN50
080L 860 1300 1740 60 412 479 / 886 1216 DN50 DN50
100L 860 1525 1740 60 412 479 / 886 1441 DN50 DN50
150L 860 1980 1880 63 412 381 286 1046 1896 DN65 DN65
200L 1000 2350 2040 63 486 438 335 1046 2266 DN65 DN65
250L 1000 2500 2200 63 486 438 335 1206 2416 DN65 DN65
300L 1000 2780 2300 80 486 565 450 1286 2696 DN80 DN80
350L 1000 3200 2300 80 486 565 592 1286 3116 DN80 DN80
400L 1000 3310 2300 80 486 565 592 1286 3226 DN80 DN80
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 16/20
Optional
Air Volume
The specifications show the standard units with standard air volume. Also the units with different
air volume from 1000 m3 /h to 40000 m3 /h can be customized as required, such as 1500 m3/h,
13500 m3/h, 27000 m3/h and etc.
Exhaust Direction
Suspended Unit
Standard:Lower horizontal, Code FB (Recommended) Optional: Upper horizontal, Code FT
Suspended Unit
Standard:Lower horizontal, Code FT (Recommended) Optional: Upper horizontal, Code FB
Vertical Unit
Standard:Front Up, Code UF (Recommended) Optional: Back Up, Code UR
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 17/2017
Coil Rows
Standard Coil: 4 Rows (A) and 6 Rows (B). 2 Rows and 8 Rows (C) can be customized as
required. The standard working pressure of all the coils is 1.6MPa.
Filter
The standard filter is panel type aluminum washable pre-filter which efficiency is G3. They are
installed in the track on the air inlet frame and can be drawn out from both sides for check and
maintenance. Also the other prefilter and the middle-efficiency filters are optional, which
efficiency is G2, G4, F5 and F6.
Humidifier
Line-style wet film humidifier is optional. The thickness of the film is 50-200mm.
Electrical HeaterBeside the coil, the unit can be equipped with a certain power electrical heater for heating.
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 18/2018
Water Drop Eliminator
Wet deck drop eliminator is optional as required to stop the water drops.
Power Source
The standard power source is “415V-3¢-50Hz”. The others are optional.
Control
If detailed control requirement is given, we can provide some control cabinet such as step-down
starter and inverter.
Other Accessories
UV germicidal lamp, 24V maintenance lamp, view window, water proof seal and etc.
Note:
The optional items may change the specifications, dimensions, cost and prices, delivery time of the standard units.
8/4/2019 2010 Double Skin Air Handling Unit
http://slidepdf.com/reader/full/2010-double-skin-air-handling-unit 19/2019
3D Exploded View
1—Base; 2—Bottom Panel; 3—Pipe Seal; 4—Panel with Hole;5—Wiring Box; 6—Quadrangle Aluminum Frame; 7—Handle; 8—Access Panel;9—Pentagon Aluminum Frame; 10—3-way Connector; 11—Air Outlet Panel; 12—Air Outlet Flange; 13—FanSupporter; 14—Fan Assembly; 15—Top Panel; 16—Coils; 17—Drain Pan; 18—Up Air Baffler; 19—Side Panel;
20—Prefilter; 21—Right Air Baffler; 22—Air Inlet Flange; 23—Left Air Baffler; 24—Supporter of Drain Pan
Note:
The upper picture is only for reference while assembling.