Siemens Building Technologies Building Technologies
SED2 Drive Applications
![Page 2: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/2.jpg)
Siemens Building Technologies Building Technologies
Simple Applications
INPUTS OUTPUTS
ACTION
0-10 V
On
FaultReset
Relay 1-> Fault
Relay 2-> Run
![Page 3: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/3.jpg)
Siemens Building Technologies Building Technologies
Standard I/O
0-10 V
2-10 V
0-20 mA
4-20 mA
Programmablefunctions
Form C contacts
Programmablefunctions
30VDC, 5A
240VAC, 2A
2 x analog outputs
2 x digital outputs
RS-485
P1
N2
USS
LonWorks (opt.)
Modbus (opt.)
0-10 V
2-10 V
0-20 mA
4-20 mA
Ni 1000
2 x analog inputs
6 x digital inputs
1 x motor PTC
Insulated
Programmablefunctions
PNP or NPN (sink/source)
SED2
![Page 4: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/4.jpg)
Siemens Building Technologies Building Technologies
Application - Air Temperature Control, Cooling
TSP=25°C
100 %
0 %SED 2
SPTC
M
p
BI ~3 AI
BI
Digital Input Analog Input
Digital Input
Function Description-Exhaust fan –-Air flow monitoring (External, only alarm)-Room temperature control, cooling-Sensor Ni 1000 -Set point +25°C-Thermostat for switch on/off
![Page 5: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/5.jpg)
Siemens Building Technologies Building Technologies
Solution: PID Controller Direct Sensor Connection
Ni 1000Sensor
Ni 1000 Temperature Sensor
Drive Based PID w/ Hibernation Mode
![Page 6: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/6.jpg)
Siemens Building Technologies Building Technologies
Ni 1000 I/O
SED2
Ni 1000 Analog input
Digital input1 Safety Input
![Page 7: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/7.jpg)
Siemens Building Technologies Building Technologies
Function Description-Constant pressure (P)-Pump Logic Controller (B&G Buster package)-P1, P2 and P3 on-off with motor starters
P3
P1
P2
M
SED 2
SP
M
M
BO BO
P
~3
PC
100 %
P
SP=2.5 bar
0 % P1
P1
P1
P2
P3
Application - Water Pressure Control
![Page 8: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/8.jpg)
Siemens Building Technologies Building Technologies
Solution: Built-In Pump Cascading
P
This function allows for control of up to two additional, cascaded pumps. With the two relay output contacts, the SED2 performs the cascading logic without additional controllers or I/O cards.
-No separate controller required
-Energy savings with SED2
Pre
ssu
re d
em
an
d
100%
2. 3.1.
Cascade
![Page 9: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/9.jpg)
Siemens Building Technologies Building Technologies
SED2
Pump Staging I/O
2 x analog input
6 x digital input 2 x digital output
0-10 volt
Pressure
Transmitter
1 On Command
1 safety input
2nd stage pump
3rd stage pump
![Page 10: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/10.jpg)
Siemens Building Technologies Building Technologies
Application – Temp. Control + Belt Monitoring
Function Description-Exhaust fan –-Air flow monitoring (External, only alarm)-Room temperature control, cooling-Sensor Ni 1000 -Set point +25°C-Thermostat for switch on/off-Belt monitoring
SED 2
SPTC
M
p
BI ~3 AI
BI
TSP=25°C
100 %
0 %
![Page 11: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/11.jpg)
Siemens Building Technologies Building Technologies
Solution: V-Belt Monitoring
The SED2 ensures reliable V-belt monitoring without the expense of an external sensor. Both speed and torque are compared to a user-defined tolerance band. If the parameters do not match, the drive trips in the event of V-belt failure.
Also, the SED2 is able to monitor a pulse sequence from the sensor detecting rotation of the fan shaft.
Speed
Torque
![Page 12: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/12.jpg)
Siemens Building Technologies Building Technologies
Application – Temp. Control + Duct Pressure Control
Function Description-Exhaust fan = Like air temperature control example-Air flow monitoring (External, only alarm)-Static pressure control-0-10v, 1-4inch wg-Set point 2.5 inch-Thermostat for switch on/off
IWGSP=2.5
100 %
0 %SED 2
SPTC
M
p
BI ~3 AI
BI
![Page 13: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/13.jpg)
Siemens Building Technologies Building Technologies
Solution: Duct Pressure Control
• 0 – 10 Volt standard output signal
• 1% Accuracy over full scale
• Available in uni-directional ½”, 1”, 2” and 5” wc
• Available in bi-directional ¼” wc.
Speed Reduction
Pressure
![Page 14: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/14.jpg)
Siemens Building Technologies Building Technologies
Static Pressure Control I/O
2 x analog input
6 x digital input
SED2
0-10 volt
Pressure
transmitter
1 On Command
1 Safety
Static Pressure Switch
![Page 15: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/15.jpg)
Siemens Building Technologies Building Technologies
Bundled Package
The SED2 is equipped with TEC application 2722
Which includes 99 subpoints
for monitoring and control
(See Attached Document for TEC Schedule)
![Page 16: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/16.jpg)
Siemens Building Technologies Building Technologies
Control Board
2 0 2 1 2 2 2 3 2 4 2 5
2 9 3 01 7 2 6 2 7 2 81 2 1 3 1 4 1 5 1 6
1 0 1 16 7 8 91 2 3 4 5
ON
1
RL1NC
RL1NO
RL1COM
RL2NC
RL2NO
RL2COM
AOUT1+
AOUT1-
PTCA
PTCB
DIN5
DIN6
AOUT2+
AOUT2-
ISO0V
P+ N-
RS-485
10V 0V AIN1+
AIN1-
DIN1
DIN2
DIN3
DIN4
ISO24V
AIN2+
AIN2-
AIN1On = [A], 0 - 20 mAOff = [V], 0 - 10 V
AIN2On = [A], 0 - 20 mAOff = [V], 0 - 10 V
V: 0 - 10 V2 - 10 V
I: 0 - 20 mA4 - 20 mA
P1; N2 USS
ErrorRun
Fn
2
519
2Z2
8en
DIN1 - I/ODIN2 - ReverseDIN3 - Fault acknowledge /
![Page 17: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/17.jpg)
Siemens Building Technologies Building Technologies
Control Terminals
Digital Inputs Terminals Parameter Default
1 5 P0701=1 ON right
2 6 P0702=12 Reverse
3 7 P07a03=9 Fault Acknowledge
4 8 P0704=15 Fixed Frequency
5 16 P0705=15 Fixed Frequency
6 17 P0706=15 Fixed Frequency
Digital Outputs Terminals Parameter Default Operation
1 18,19,20 P0731 Drive fault
2 23,24,25 P0732 Drive running
Analog Inputs * Terminals Parameter Default Operation
1 3,4 P0756(0) 0-10V dc
2 10,11 P0756(1) 0-10V dc
Analog Outputs Terminals Parameter Default Operation
1 12,13 P0771(0) Frequency
2 26,27 P0771(1) Frequency
* Can also be configured as NI1000 inputs.
![Page 18: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/18.jpg)
Siemens Building Technologies Building Technologies
Mounting & Installation Considerations
• Type of environment
- What is the location like? Does it fall within the drives operating ranges for altitude & temperature
• Type of power
- Line and load reactors reduce voltage. If voltage is already low, using them could have an effect on performance.
- Does the power system supply at least 1% impedance?• Type of motor
- Is it VFD rated?
- Distance from the drive?
- HP of the motors?
- Age of the motor?
![Page 19: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/19.jpg)
Siemens Building Technologies Building Technologies
Enclosure Ratings - Drive & Drive W/Bypass
• IP 20– No NEMA equivalent, needs to be mounted in another
enclosure– Generally used in US for OEM applications– Our standard unit as it comes from the factory
• IP 21– NEMA 1, protects operator from electrical hazard and
protects the equipment from falling material– Our standard unit when fitted with gland plate and dust
cover
• IP 54– No direct US equivalent, but exceeds NEMA 12– NEMA 3R– Water tight, limited need in drive applications
![Page 20: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/20.jpg)
Siemens Building Technologies Building Technologies
Mounting & Installation Considerations
Line Reactor Installation• Not recommended to reduce Harmonics• Can be ordered with or without an enclosure• Installed to protect the drive from:
– Power spikes or sags caused from transfer to generator– Poor heavy switch load on the same load center
![Page 21: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/21.jpg)
Siemens Building Technologies Building Technologies
Mounting & Installation Considerations
Load Reactor Installation• Long wire leads from drive to motor
– As wire length from drive to motor increases, the voltage spike increases – Can be ordered with or without an enclosure– Installed to protect the motor from:– Spikes caused from the drive switching frequencies or IGBT
![Page 22: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/22.jpg)
Siemens Building Technologies Building Technologies
Mounting & Installation Considerations
Line and Load Reactor Installation• Always use Siemens Building Technologies specified
reactor• For retro-fit applications
– REMOVE AND REPLACE EXISTING REACTORS WITH SBT SPECIFIED REACTORS
![Page 23: 2 Sed2 Drive Applications](https://reader033.fdocuments.us/reader033/viewer/2022052906/5589301cd8b42a30608b4625/html5/thumbnails/23.jpg)
Siemens Building Technologies Building Technologies
Siemens SED2 VFD Advantages
• Low harmonics design• Small enclosure size• Many standard
features• Reduces operating
cost• Low power losses/high
efficiency• Minimal effect on
customer power• Wide power range –
from ½ to 125 HP