TOPC-E4011E-01-xxxxxx
PASOLINK NEO LCT PASOLINK NEO LCT LOCAL CRAFT TERMINALLOCAL CRAFT TERMINAL
Provided for Training July 2007
PASOLINK NEO LCT PASOLINK NEO LCT 11TOPC-E4011E-01-xxxxxx
LCT COMMUNICATION INTERFACELCT COMMUNICATION INTERFACE
COMMUNICATION BETWEEN THE LCT AND THE PASOLINK NEO IS VIA THE LCT PORT OF THE CTRL MODULE.THE LCT AND THE CTRL MODULE MOUNTED ON THE PASOLINK NEO MUST BE CONNECTED USING A USB A-B TYPE CABLE. TYPE-B CONNECTS TO THE LCT PORT.
LCT PC SPECIFICATION
CPU PENTIUM-M 1.6GHz OR BETTER
RAM 512MB OR MORE
HDD 100 MB OR MORE FREE CAPACITY
DISPLAY COLOR LCD (1024x768)
CD ROM DRIVE/USB-PORT / USB CABLE WITH USB-B CONNECTOR
JAVA RUNTIME ENVIRONMENT V1.5.0_05 OR HIGHER
LCT WEB SOFTWARE (VER 2.XX.XX)
IE 6 WITH SP2 PR HIGHER
WINDOWS 2000 (ENGLISH) WITH SP4 OR HIGHERWIN DOWS XP PROFESSIONAL (ENGLISH) SP2
OS
SOFTWARE REQUIREMENT
(Open Application on LCT)INCOMPATIBLEPlease change LCT
CTRL: 3.xx.xx
(Open Browser and input URL)(Open Browser and input URL)CTRL: 2.xx.xx
LCT: 2.xx.xxLCT: 1.xx.xx
IDU AND LCT COMPATIBILITY
There are two types of LCT version corresponding to the IDU F/W version installed. LCT WEB applet Version 1.(Rev 1.xx.xx) is installed in the IDU and the LCT WEB Version (Rev 2.xx.xx) is installed in the PC.
PASOLINK NEO LCT PASOLINK NEO LCT 22TOPC-E4011E-01-xxxxxx
LCT COMMUNICATION INTERFACELCT COMMUNICATION INTERFACE
MAKE THE LCT DIALUP CONNECTION
OPEN THE IE BROWSER AND ENTER THE URL
LOGIN: Admin AND ENTER PASSWORD
INSTALL USB MODEM DRIVER (NEC)INSTALL JAVA 2 RUN TIMECREATE A DIAL UP CONNECTION NAMED LCT
1
3
DEFAULT PASSWORD: 12345678
2
For LCT Ver. 1.xx.xx & CTRL Ver. 2.xx.xx
Http://172.17.254.253INSTALL FROM THE LCT WEB SETUP FILES CD,
JAVA RUN TIME
USB DRIVER
PASOLINK NEO LCT PASOLINK NEO LCT 33TOPC-E4011E-01-xxxxxx
LCT COMMUNICATION INTERFACELCT COMMUNICATION INTERFACE
MAKE THE LCT DIALUP CONNECTION
START THE LCT FOR STDLOGIN: Admin AND ENTER PASSWORD
INSTALL USB MODEM DRIVER (NEC)
INSTALL JAVA 2 RUN TIMECREATE A DIAL UP CONNECTION NAMED LCT
1
3
DEFAULT PASSWORD: 12345678
INSTALL THE LCT WEB IN THE PC2
For LCT Ver. 2.xx.xx & CTRL Ver. 3.xx.xx
INSTALL FROM THE LCT WEB SETUP FILES CD,
JAVA RUN TIME *
USB DRIVER
LCT-WEB APPLET
* In later versions Java Run Time will be included in the LCT WEB Applet
PASOLINK NEO LCT PASOLINK NEO LCT 44TOPC-E4011E-01-xxxxxx
LCT LOGINLCT LOGIN
ENTER THE USER NAME “Admin” AND PASSWORD
(DEFAULT PASSWORD IS”12345678”
CLICK THE “LOGIN”
LCT WEB OPENS TO ALARM/STATUS WINDOW
1
2
Two User ID’s are defined “Admin” (with Password) and “User” (without PW )
USER ID : AdminWITH PASSWORD, ACCESS LCT FOR MONITOR & CONTROL
USER ID : UserWITHOUT PASSWORD, ACCESS LCT FOR MONITOR ONLY
PASOLINK NEO LCT PASOLINK NEO LCT 55TOPC-E4011E-01-xxxxxx
LCT MENULCT MENU
CH Setting-1
CH Setting-2
BER Threshold Setting
SC Assignment
LAN Port Setting
TX Power Control
Condition for TX/RX SW
Relay Setting
TCN Threshold (15min)TCN Threshold (1day)
PMON Select
Others
User Interface
Redundancy Setting
INTFC (Work)
INTFC (Prot)
XPIC Usage
APS Function
Modulation Scheme
Transmission Capacity
TX RF Frequency[MHz]RX RF Frequency[MHz]
Frame ID
TX Power Control
STM-1 Setting
ALS Function
Condition for APS
LAN Port Usage (Main)
LAN Capacity (Main)
PDH E1 with LANPDH E1
PDH E3 with LANSDH STM-1
1 + 1 (Hot Standby TERM)1 + 0 (TERM)
1 + 1 (Twin Path TERM)
48 x E1 PKG16 x E1 Standard PKG (E/W LAN)
4 Port LAN with E1
4 Port LAN with E1
2 WAY PDH (REP)
STM-1 (Optical)STM-1 (Electrical)1 x E3 +4E1 PKG (E/W LAN)2 x E3 +8E1 PKG (E/W LAN)
E3 Setting
STM-1 (Optical) for APSNot Used
WS / LAN
Used (Main Master)Not Used
Used (SUB Master)
UnavailableAvailable
16QAMQPSK
32QAM128QAM
10 [MB]20 [MB]40 [MB]80 [MB]80 [MB]100 [MB]156 [MB]
Frame ID 1 - 32
ATPCMTPC
NOT USEDP1-2 Shared/1 Port Only(Main)P1-2 Shared/1 Port Only(SC)P1-2 Separated(Main)
CH # LAN ( Status)CH #
CH Usage Error Report
AIS Activation Condition
AIS Generation ReportAIS Received ReportAIS Received Condition
E1 Port Impedance (CH#)
High BER ThresholdLow BER ThresholdE-BER (DMR)SD (DMR)E-BER (MUX)SD (MUX)
ATPC Trehsold Level [dBm]Additional ATT [dB]ATPC Range [MAX] [dB]ATPC Range [MIN] [dB]ATPC Power Mode
ATPC Trehsold Level [dBm]Additional ATT [dB]
MTPC TX Power [dB]
MS - AIS Generation
ALS FunctionALS Interval
TX SW Priority
RX SW PriorityRX SW Maintenance Mode
RX SW Condition Early Warning
APS Maintenance ModeAPS Condition-SF(PROT)APS Condition-SD (B1)
Lock in Count (times)Lock in Usage
Lock in Detect Time (mins)Lock in Hold Time (mins)
HK OUT 1 to 4 setting
CLUSTER ALM OUT 1 to 4 settingPASOLINK ALM OUT settingCLUSTER ALM IN 1 to 4 setting
RX Level TCN Threshold [dBm]SES Activation
EOW2 Wxternal SettingAlarm Correlation Capability
Switching Function2M Frame
Port UsageSpeed & DuplexFlow ControlCollision ReportLink Loss Forwarding
LAN PORT SETTING
Por
t 1 P
ort 2
RX SW Manual ControlTX SW Manual ControlTX Mute ControlCW ControlAPS Manual Control
DADE Adjust
Linearizer Control
XPIC Control
RF SettingAntenna Alignment Mode
Main Loopback(Near End)IF Loopback
Main Loopback(Far End)
ALS Restart
Maintenance
OFFLine Maintenance
Download Configuration File
Password SettingDate / Time Setting
PMON Clear
CPU Reset
Download Program FileDownload Equip Config FileUpload Configuration FileUpload Equip Config File
Maintenance -1
Maintenance -2
ProvisioningEquipment Setup
XPIC Condition - Local Fail REF LO>>Self LONormal InvertOFF OFF
Mute
30% 15%
Disabled Enabled
RL-3RL-4RL-5RL-6
Manual ForcedPriority High Priority LowInclude SD Exclude SDUsed Notused
Include EW Exclude EWManual Forced
Non Priority Priority No.1
Hold Max Min
Disabled180Sec 300Sec60Sec
Enabled
Disabled Enabled
Disabled EnabledReport Not ReportON OFF
Used Not Used
Disabled Enabled
120 Ohms 75 OhmsLOF+HBER LOFAlarm Status
Report Not Report
Used Not Used
PASOLINK NEO LCT PASOLINK NEO LCT 66TOPC-E4011E-01-xxxxxx
LCT WINDOWLCT WINDOW
MAIN DISPLAY AREA
SUMMARY ALARM STATUS AREAPROGRESS AREA
MENU AREA
COMMON AREA
DISPLAY THE MAIN LCT MENU AND EXPANDED MENUS FOR PROVISIONING, MAINTENANCE AND PMON
COMMON AREA DISPLAY COMMON CONTROL BUTTONS SET, LOGOUT, RELOAD.
DISPLAY THE RESULTS OF THE SET CONTROLS: “OK’ OR “NG”
DISPLAY THE SUMMARY ALARMS OF NEO MAIN UNITS AND MAINTENANCE STATUS
DISPLAY THE LOGIN NAME AND SOFTWARE VER.
DISPLAY THE DETAILS OR CONTROL ITEMS OF THE SELECTED LCT MENU ITEM
PASOLINK NEO LCT PASOLINK NEO LCT 77TOPC-E4011E-01-xxxxxx
ALARM & STATUS ALARM & STATUS --PDHPDH
Modem Detail
ODU Detail
Interface Detail PMON Detail
CTRL Detail
Alarm/Status Color Code
PASOLINK NEO LCT PASOLINK NEO LCT 88TOPC-E4011E-01-xxxxxx
ALARM & STATUS ALARM & STATUS --SDHSDH
Modem Detail
ODU Detail
Interface Detail
PMON Detail
CTRL Detail
Alarm/Status Color Code
PASOLINK NEO LCT PASOLINK NEO LCT 99TOPC-E4011E-01-xxxxxx
ALARM & STATUS ALARM & STATUS --SDHSDH
Modem Detail
ODU Detail
Main/Sub Interface Detail
PMON Detail
CTRL Detail
Unavailability status
PASOLINK NEO LCT PASOLINK NEO LCT 1010TOPC-E4011E-01-xxxxxx
EQUIPMENT SETUPEQUIPMENT SETUP
WHEN SDH INTFC IS SELECTED
AFTER SELECTING ALL THE CONFIGURATION SETTINGS CLICK THE
SET BUTTON TO IMPLEMENT THE
SETTING
WHEN PDH INTFC IS SELECTED
PASOLINK NEO LCT PASOLINK NEO LCT 1111TOPC-E4011E-01-xxxxxx
PROVISIONING PROVISIONING –– PDHPDH
WHEN MTPC IS SELECTED IN EQUIPMENT SETUP
WHEN ATPC IS SELECTED IN EQUIPMENT SETUP
PASOLINK NEO LCT PASOLINK NEO LCT 1212TOPC-E4011E-01-xxxxxx
PROVISIONING PROVISIONING –– PDHPDH
PASOLINK NEO LCT PASOLINK NEO LCT 1313TOPC-E4011E-01-xxxxxx
PROVISIONING PROVISIONING –– PDH LAN SETTINGPDH LAN SETTING
WHEN THE LAN CAPACITY IS SET TO 2MB, 2M FRAMING ITEM APPEARS
THIS MENU CONFIGURE THE LAN PORT PARAMETERS WITHIN THE LAN CAPACITY (MAIN) AND LAN PORT USAGE (MAIN) SETTING IN THE EQUIPMENT SETUP
LAN PORT SETTING FOR 16E1 AND 2-PORT LAN INTERFACE CARD
PASOLINK NEO LCT PASOLINK NEO LCT 1414TOPC-E4011E-01-xxxxxx
PROVISIONING PROVISIONING –– SDHSDH
SELECT THE BER THRESHOLD SETTING FOR THE RADIO LINK AND FOR THE STM-1 SIGNAL FROM MUX & RADIO DIRECTIONS.
TWO V.11 & TWO RS232 USER CHANNELS CAN BE ASSIGNED TO DSC 1 TO 4 IN THE RFCOH OR THEY CAN BE ASSIGNED TO E1, F1 & DCCr BYTES IN THE RSOH IN THE DIRECTION OF MUX OR RADIO (DMR).
E1 (MUX) E1 (DMR)F1 (DMR)F1 (MUX)
E1 (MUX)F1 (MUX)
DCCr (MUX)V.11
DSC1 TO 4V.11 & RS-232C
DCCr (DMR) DCCr (MUX)
SC LAN DSC1 TO 4
V.11 & RS-232CV.11 & RS-232C
SDH
CLICK ON THE APPROPRIATE RADIO BUTTON TO SELECT THE THRESHOLD SETTING
CLICK ON THE ARROW AND SELECT FROM THE DROP DOWN MENU THE USAGE FOR EACH USER CHANNEL . WHEN V.11 CH IS USED SELECT THE DIRECTION SETTING FROM THE APPROPRIATE RADIO BUTTON
AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.
PASOLINK NEO LCT PASOLINK NEO LCT 1515TOPC-E4011E-01-xxxxxx
PROVISIONING PROVISIONING –– STMSTM--1 SETTING1 SETTING
MS-AIS GENERATION SETTING IS USED TO STOP SENDING MS-AIS SIGNAL DUE TO RADIO LINK OR EQUIPMENT FAILURE.
WHEN DISABLED:- DURING FAILURE OPTICAL INTFC WILL STOP TRANSMITTING THE OPTICAL SIGNAL, ELECTRICAL INTFC WILL SEND UNFRAMED AIS.
WHEN ENABLED:- SEND MS-AIS DUE TO RADIO LINK OR EQUIPMENT FAILURE.
AUTOMATIC LASER SHUT DOWN (ALS) FUNCTION IS AVAILABLE ONLY FOR OPTICAL INTFC . DURING LOS OF SIGNAL AT THE INPUT OF THE OPTICAL INTFC IT WILL CUT THE LASER OUTPUT FROM THE OUTPUT OF THE OPTICAL INTFC. DURING THIS TIME AT DEFINED INTERVALS INTFC WILL OUTPUT A 2 SEC LASER PULSE.
SELECT ENABLE OR DISABLE FROM THE ALS FUNCTION RADIO BUTTON
IF ENABLE IS SELECTED, SELECT ALS INTERVAL FROM 60, 180, AND 300 SEC .
AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.
PASOLINK NEO LCT PASOLINK NEO LCT 1616TOPC-E4011E-01-xxxxxx
PROVISIONING PROVISIONING -- APSAPS
AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.
APS CONDITION –SF (PROT) APPLIES WHEN FORCED MANUAL SWITCHOVER TO PROTECTION INTFC IS MADE
PRIORITY HIGH: WHEN SIGNAL FAIL (SF) OCCURS IN THE PROTECTION INTFC, KEEPS THE ONLINE, ON WORK INTFC
PRIORITY LOW: IGNORE THE SIGNAL FAIL CONDITION IN FORCED MANUAL, SWITCHOVER TO PROT INTFC
THIS MENU ITEM APPEARS WHEN APS FUNCTION AVAILABLE, IS SET IN THE SETUP CONFIGURATION. OPTICAL INTFC SHOULD BE MOUNTED IN MAIN & SUB SLOTS
APS MAINTENANCE MODE:
MANUAL: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, PREVENT SWITCHING TO AN ALARMED INTFC (ROUTE)
FORCED: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, FORCIBLY SWITCH TO THE SELECTED INTFC DISREGARDING IT’S ALARM STATUS ( THIS MAY INTERRUPT TRAFFIC)
APS CONDITION –SD (B1)
INCLUDE SD: SELECT THIS TO CONSIDER STM-1 SIGNAL DEGRADE (SD) AS A CONDITION FOR APS SWITCHING
EXCLUDE SD: SELECT THIS TO EXCLUDE STM-1 SIGNAL DEGRADE (SD) AS A CONDITION FOR APS SWITCHING
LOCK IN USAGE
USED: WHEN FREQUENT SWITCHING OCCURS BETWEEN WORK & PROT, PAUSE SWITCHOVER UNTIL CONDITIONS SET IN LOCK IN COUNT, LOCK IN DETECT TIME & LOCK IN HOLD TIME ARE MET
NOT USED: ALLOW FREQUENT SWITCH OVER BETWEEN WORK & PROT INTFC.
LOCK IN USAGE SET TO USED
LOCK IN COUNT: NUMBER OF SWITCHOVERS DETECTED WITHIN LOCK IN DETECT TIME TO PAUSE SWITCHOVER ACTION
LOCK IN DETECT TIME: SET THE TIME IN MINUTES. DURING WHICH THE NUMBER OF SWITCHOVER ARE COUNTED FOR LOCK IN FUNCTION
LOCK IN HOLD TIME: SET THE DURATION OF SWITCHOVER PAUSE IN HOURS AFTER LOCK IN IS SET.
PASOLINK NEO LCT PASOLINK NEO LCT 1717TOPC-E4011E-01-xxxxxx
PROVISIONING PROVISIONING –– COMMONCOMMON
RX SW MAINTENANCE MODE:
MANUAL: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, PREVENT SWITCHING TO AN ALARMED CHANNEL (ROUTE)
FORCED: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, FORCIBLY SWITCH TO THE SELECTED CH DISREGARDING IT’S ALARM STATUS ( THIS MAY INTERRUPT TRAFFIC)
RX SW CONDITION EARLY WARNING:
INCLUDE EW: SELECT THIS TO INCLUDE EW AS A CRITERIA FOR AUTO REDUNDANCY SWITCHING IN (1+1) CONFIGURATION
EXCLUDE EW: SELECT THIS TO EXCLUDE EW AS A CRITERIA FOR AUTO REDUNDANCY SWITCHING IN (1+1) CONFIGURATION
EARLY WARNING BER SETTING IS 1E-9
TX & RX SW PRIORITY
NON PRIORITY: SELECT THIS FOR NON HOMING SWITCHING.
PRIORITY NO.1: SELECT THIS FOR HOMING SWITCHING. WHEN BOTH CHANNELS ARE NORMAL USE No.1 AS ONLINE. CH NO.1 FAILS SWITCH TO CH NO.2, WHEN CH NO.1 IS NORMALIZED SWITCH BACK TO CH NO.1 AUTOMATICALLY
PASOLINK NEO LCT PASOLINK NEO LCT 1818TOPC-E4011E-01-xxxxxx
PROVISIONING PROVISIONING –– TX POWER CONTROLTX POWER CONTROL
No.1 & No.2 IS INDICATED FOR (1+1) TWIN PATH CONFIGURATION
MTPC MODE:
MPTC TX POWER : ENTER A NEGATIVE VALUE IN dB (AMOUNT OF ATTENUATION FROM THE ODU NOMINAL TX POWER)
ATPC THRESHOLD: ENTER THE RX THRESHOLD VALUE TO BE USED WHEN OPPOSITE STATION IS IN ATPC MODE
(SET IN 1 dB STEPS)
TX POWER CONTROL - ATPC TX POWER CONTROL - MTPC
ATPC MODE:
ATPC THRESHOLD: ENTER THE RX THRESHOLD VALUE TO BE USED WHEN OPPOSITE STATION IS IN ATPC MODE
ADDITIONAL ATT: 0 TO 5 dB ADDITIONAL ATTENUATION IN 1 DB STEPS ( IN ADDITION TO THE ATPC RANGE) (DEPENDS ON THE MODULATION)
ATPC RANGE (MAX): MAXIMUM POWER LEVEL UNDER ATPC CONTROL IS DEFINED BY THIS ITEM (AMOUNT OF ATTENUATION FROM THE ODU NOMINAL TX POWER)
ATPC RANGE (MIN): MINIMUM POWER LEVEL UNDER ATPC CONTROL IS DEFINED BY THIS ITEM (AMOUNT OF ATTENUATION FROM THE ODU NOMINAL TX POWER)
ATPC POWER MODE: THIS ITEM DEFINED THE ODU TX POWER SETTING DURING ATPC CONTROL FAILURE
HOLD: TO MAINTAIN THE CURRENT TX POWER AT THE TIME OF ATPC CONTROL FAILURE
SELECT : MAX: TO TRANSMIT AT ATPC MAX POWER LEVEL AT THE TIME OF ATPC CONTROL FAILURE
MIN: TO TRANSMIT AT ATPC MIN POWER LEVEL AT THE TIME OF ATPC CONTROL FAILURE
AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.
PASOLINK NEO LCT PASOLINK NEO LCT 1919TOPC-E4011E-01-xxxxxx
PROVISIONING PROVISIONING –– RELAY SETTINGRELAY SETTING
WHEN THE LAN CAPACITY IS SET TO 2MB, 2M FRAMING ITEM APPEARSA: HOUSE KEEPING CONTROL SETTING
B: CLUSTER ALARM OUTPUT SETTING
C: PASOLINK ALARM RELAY ASSIGNMENT FOR PARALLEL ALARM OUTPUT
CLUSTER ALARM INPUT ENABLE / DISABLE
IMPORTANT: FOR CLUSTER ALARM INPUT/OUTPUT, CORRESPONDING CLUSTER ALARM OUTPUT/INPUT IN THE OPPOSITE STATION MUST BE ASSIGNED OR ENABLED.
CLICK ON A BUTTON TO ASSIGN TO RELAYS
IMPORTANT: FOR EACH RELAY, SELECT FROM ONE CATEGORY ONLY ( FROM A OR B OR C)
PASOLINK NEO IDU HAS 6 RELAYS WHICH CAN BE ASSIGNED TO OUTPUT PASOLINK ALARMS, CLUSTER ALARM OUTPUT AND HOUSEKEEPING ALARMS.
PASOLINK NEO LCT PASOLINK NEO LCT 2020TOPC-E4011E-01-xxxxxx
PROVISIONING PROVISIONING –– TCN THRESHOLD SETTINGTCN THRESHOLD SETTING
TCN THRESHOLD (15MIN): ENTER THE TCN THRESHOLD VALUES FOR ALARM OCCUR AND ALARM RECOVER FOR MUX DIRECTION AND DMR DIRECTION
TCN THRESHOLD (1 DAY): ENTER THE TCN THRESHOLD VALUES FOR ALARM OCCUR AND ALARM RECOVER FOR MUX DIRECTION AND DMR DIRECTION
TCN THRESHOLD (15 MIN)
TCN THRESHOLD (1 DAY)
PASOLINK NEO LCT PASOLINK NEO LCT 2121TOPC-E4011E-01-xxxxxx
PROVISIONING PROVISIONING –– PMON SELECTPMON SELECT
RX LEVEL TCN THRESHOLD: ENTER THE RX LEVEL THRESHOLD FOR TCN ALARM. No.1 or 2 FOR (1+1) CONFIGURATION
SES ACTIVATION CONDITION: SELECT THE APPROPRIATE RADIO BUTTON FOR PERCENTAGE OF BLOCKS IN ERROR FOR SES ACTIVATION
PMON SELECT
PASOLINK NEO LCT PASOLINK NEO LCT 2222TOPC-E4011E-01-xxxxxx
PROVISIONING PROVISIONING -- OTHERSOTHERS
OTHERS
EOW2 EXTERNAL SETTTING: THIS SETTING IS FOR BACK TO BACK CONNECTION OF EOW CALLING SIGNAL BETWEEN DIFFERENT TYPES OF PASOLINK EQUIPMENT.
INVERT : SELECT THIS FOR CONNECTION BETWEEN PASOLINK+ & MX IDU
NORMAL: SELECT THIS FOR CONNECTION BETWEEN PASOLINK IDU & NEO IDU
ALARM CORRELATION CAPABILITY: THIS SETTING IS TO FILTER THE ALARMS AND GIVE THE MAIN (ROOT) CAUSE OF THE ALARM
OFF : CORRELATION OFF GIVES THE MAIN ALARM AS WELL AS THE SECONDARY ALARMS
NORMAL: CORRELATION ON, GIVES MAIN CAUSE OF THE FAILURE
PASOLINK NEO LCT PASOLINK NEO LCT 2323TOPC-E4011E-01-xxxxxx
METERINGMETERING
(1+0) configuration
(1+1) Configuration Hot Standby
+09.0-50.4
PASOLINK NEO LCT PASOLINK NEO LCT 2424TOPC-E4011E-01-xxxxxx
INVENTORYINVENTORY
ODU Information
IDU module Information
IDU module FPGA Information
Modem Version Information
IDU Network Properties
Softkey related information
PASOLINK NEO LCT PASOLINK NEO LCT 2525TOPC-E4011E-01-xxxxxx
AUXILIARY I/OAUXILIARY I/O
INPUT:
Close: Indicate HK ALM inputcondition
Close: Indicate HK control sent out
Shading indicates HK controls are not assigned
Click on the arrow and select Open or Close to send a Control signal and click the SET Button
Inputs 3, 4, 5 and 6 are common to HK alarm input and Cluster alarm input. When Cluster alarms are enabled in Provisioning it cannot be used for HK ALM Input
OUTPUT:
Outputs 1, 2, 3 and 4 are common to both HK Controls and Cluster Alarm outputs. Only one type should be assigned to each output.
CLICK “SET” TO SEND SELECTED CONTROL SIGNAL
HOUSE KEEPING ALM INPUT CAN BE MONITORED ONLY FROM LCT.PNMx
CLUSTER ALM INPUTS CAN BE TAKEN OUT FROM THE OPPOSITE STATION CLUSTER ALM OUT RELAY.
PASOLINK NEO LCT PASOLINK NEO LCT 2626TOPC-E4011E-01-xxxxxx
MAINTENANCE 1 & 2 (PDH)MAINTENANCE 1 & 2 (PDH)
SELECT THE MAINTENANCE CONTROL ITEM AND CLICK ON THE CORRESPONDING SET BUTTON
MAINTENANCE CONTROL STATUS IS INDICATED IN THE VALUE COLUMN. YELLOW INDICATES MAINT CONTROL APPLIED.
MAINTENANCE 1 , HAS TWO SECTIONS ONLINE AND OFFLINE. OFFLINE MAINTENANCE ITEMS MAY CAUSE INTERRUPTION IN THE RADIO LINK
PASOLINK NEO LCT PASOLINK NEO LCT 2727TOPC-E4011E-01-xxxxxx
MAINTENANCE 1 & 2 (SDH)MAINTENANCE 1 & 2 (SDH)
SELECT THE MAINTENANCE CONTROL ITEM AND CLICK ON THE CORRESPONDING SET BUTTON
MAINTENANCE CONTROL STATUS IS INDICATED IN THE VALUE COLUMN. YELLOW INDICATES MAINT CONTROL APPLIED.
PASOLINK NEO LCT PASOLINK NEO LCT 2828TOPC-E4011E-01-xxxxxx
MAINTENANCE MAINTENANCE -- 22
To change the password
Enter the old password
Enter the new password
Re-Enter the new password for confirmation
Click Execute to change the password
Click Close to exit the change password window
Clear PMON data
This maintenance control clear the Performance Data from the IDU memory.
PASOLINK NEO LCT PASOLINK NEO LCT 2929TOPC-E4011E-01-xxxxxx
Thank youThank you