High Resolution T2 ImagingRat versus Mouse
T1 MP-RAGE
Dark CSF
Resolution Rat: 156 x 156 x 700 µm3
Mouse: 138 x 117 x 400 µm3
Coil setup:Transmit: Integrated body coilReceive: Dedicated brain 2x2 array
![Page 3: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/3.jpg)
3
T2 Imaging
Rat brain
TSE, magnetization restoreTR: 2000 msTE: 38 msTot. scan time: 3 min 10 sFoV: 35 x 35 mm² Slice thickness: 0.8 mmMatrix: 240 x 320Resolution: 146 x 109 µm2
Coil setup:Transmit: Integrated body coil Receive: Rat brain
quadrature coil
T2 imaging
Bright CSF
BGA12S
![Page 4: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/4.jpg)
T2 Map T2
1.2 x 0.182 x 0.182 mm3
Traumatic Brain Injury
![Page 5: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/5.jpg)
T2 image of injured Rat spine
Spine Injury
![Page 6: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/6.jpg)
Rat Thoracic Spine
![Page 7: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/7.jpg)
Fiber tracking rat spine – T2 backgroundpost injury
Diffusion Tensor Imaging
Fiber tracking mouse brain
Pre injury
Post injury
![Page 8: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/8.jpg)
Gadolinium-tagged drug in Nasal Passage fMRI
segmentationMouse spine
angiography
Rat knee
![Page 9: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/9.jpg)
9
Mouse Spine with the MRI CryoProbe™
Turbo-RARE-T2TR: 1000 ms Slice thickness: 0.5TE: 12.6 ms Res.: 46 x 46 µm²Matrix: 384 x 384 NA: 2Total time 6 min. 24 sec.
![Page 10: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/10.jpg)
10
• Specific animal beds:rat, mouse, rabbit
• Integrated animal warming
• Stereotactic fixation
Animal handling
![Page 11: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/11.jpg)
Cryocoil bed
![Page 12: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/12.jpg)
Mouse Cardiac Coil Rat Body/Cardiac Coil
Mouse and Rat Beds
Attached to bed
![Page 13: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/13.jpg)
Dr Edward Hall
ADC
DWIRATSingleCoronalSlice117um x 238um x 1500um
“Qualitative” Analysis - T2 map, T1 map, ADC (DTI)
![Page 14: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/14.jpg)
Rat Body/Cardiac CoilMouse Body Coil
![Page 15: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/15.jpg)
Cryo-probe images – mouse brain• FLASH T2 * weighted• TE/TR: 22/350ms• Res.: 30x30x500µm• Scantime 6min• 9.4 T
2Cb
3Cb
5&4Cb6Cb
7Cb
8Cb
10Cb
9Cb
Gray matter:molecular layer
White matter
Gray matter:granular layer
Purkinje cell layer
![Page 16: 2 High Resolution T2 Imaging Rat versus Mouse T1 MP-RAGE Dark CSF Resolution Rat: 156 x 156 x 700 µ m 3 Mouse: 138 x 117 x 400 µm 3 Coil setup: Transmit:Integrated.](https://reader036.fdocuments.us/reader036/viewer/2022062423/56649e755503460f94b76182/html5/thumbnails/16.jpg)