2. Brochure - McON Air

2
Prozess- und Messtechnik Conrads GmbH Steinfeldstr. 5 D-39179 Barleben Germany Phone +49 (0)39203 512-0 Fax +49 (0)39203 512-202 www.promecon.com [email protected] Maintenance free gas flow measurement for hot and dusty media Technical data Measurement principle: cross correlation Typical accuracy: better + / - 2% Repeatability: better 0,05 % Drift: 0% Maintenance/cleaning: none Linearity: 100 % Hysteresis: none Calibration: none Gas temperature: 10 – 400/1100 °C std / ht (50 - 750 / 2000 °F std/ht) Dust load range: 1mg – 2000g/m 3 Safety standards: SIL 2 according EN 61508 for McON air SIL Enclosure type: Rittal AE1030.500 Dimensions: 380x300x155 mm (15x12x6’’) widthxheightxdepth Material: sheet steel Material option: stainless steel enclosure AE 1004.600 Surface finish: powder coated RAL 7035 Degree of protection: IP66, NEMA 4 Weight: 10 kg (22 lbs) Mounting: wall mounting brackets Power supply: 85 – 264 VAC, 47 - 63 Hz or 24 VDC Power consumption: max. 0,8 A (115 VAC)/0,4 A (230 VAC) Recommended circuit breaker: 10 A (characteristic C or slow blow fuse) Temperature range (operation): -20/0 – 55 °C (-4 /32 – 130 °F) Temperature range (storage): -20/0 – 65 °C (-4 /32 – 149 °F) I/Os: 1x4-20 mA, 2xrelay (error contact) Dimensions and weights Online gas flow measurement Highly accurate No calibration, no drift, no cleaning Not affected even by high dust levels Works up to 1100 °C SIL 2 version available name company street postal code city phone For further information please send a fax to: Fax: +49 (0)39203 512-202 PROMECON PROMECON (or company stamp) PROMECON PROMECON PROMECON GmbH Germany Phone +49 (0)39203 512-0 [email protected] www.promecon.com power – cement – smelters M c ON air M c ON air SIL / BU-MOair-1.1-EN

description

air1

Transcript of 2. Brochure - McON Air

Page 1: 2. Brochure - McON Air

Prozess- und Messtechnik Conrads GmbH

Steinfeldstr. 5D-39179 BarlebenGermany

Phone +49 (0)39203 512-0Fax +49 (0)39203 [email protected]

Maintenance freegas flow measurementfor hot and dusty media

Technical data

Measurement principle: cross correlationTypical accuracy: better +/- 2%Repeatability: better 0,05 %Drift: 0 %Maintenance/cleaning: noneLinearity: 100%Hysteresis: noneCalibration: noneGas temperature: 10 – 400/1100 °C std/ht (50 - 750/2000 °F std/ht)Dust load range: 1mg – 2000g/m3

Safety standards: SIL 2 according EN 61508 for McON air SIL

Enclosure type: Rittal AE1030.500Dimensions: 380x300x155 mm (15x12x6’’)

widthxheightxdepthMaterial: sheet steelMaterial option: stainless steel enclosure AE 1004.600Surface finish: powder coated RAL 7035Degree of protection: IP66, NEMA 4Weight: 10 kg (22 lbs)Mounting: wall mounting bracketsPower supply: 85 – 264 VAC, 47 - 63 Hz or 24 VDCPower consumption: max. 0,8 A (115 VAC)/0,4 A (230 VAC)Recommended circuit breaker: 10 A (characteristic C or slow blow fuse)Temperature range (operation): -20/0 – 55 °C (-4 /32 – 130 °F)Temperature range (storage): -20/0 – 65 °C (-4 /32 – 149 °F)I/Os: 1x4-20 mA, 2xrelay (error contact)

Dimensions and weights

Online gas flowmeasurement

Highly accurate

No calibration,no drift, no cleaning

Not affected evenby high dust levels

Works up to 1100 °C

SIL 2 version available

name

company

street

postal code

city

phone

For further informationplease send a fax to:

Fax: +49 (0)39203 512-202

PROMECONPROMECON

(or company stamp)

PROMECONPROMECON PROMECON GmbH GermanyPhone +49 (0)39203 [email protected]

power – cement – smelters

McONair McONair SIL/

BU-MOair-1.1-EN

Page 2: 2. Brochure - McON Air

Drift and calibration free gas flow measurement Our customers´ opinion:

Installation via flange without calibration of the sensors

Installation of McON air in power station

Installation via flange without calibration of the sensors

With McON airwe don´t have tokeep cleaning themeasurement system. I now know,

that our measurementvalues are always repeatablesince they don´t drift.

Since we´ve hadMcON air we don´thave to worry aboutrecalibrating.Commissioning is

dead simple anddoesn´t need calibration -truly plug & play.

In the past thechoice was:

A conditionaldelta P measurement

measures the mass flowaccurately only for a

limited time aftercleaning. Hence acyclical purging of

the pressure tabs is necessary.

In case of foulingthe delta P measurement

will remain inaccurateeven after cleaning.

McON air gives you:

McON air will alwaysremain accurate evenwith highest dust levelssince it is based on a pertime measurement - nocleaning even at highest

dust levels (2000g/m3).The actual flow is

measured without theuse of temperature and

pressure measurements.

In addition themeasurement alwaysmonitors the plausibilityof the raw signals.

0 days 1 day 2 days 3 days 4days 5 days

m3/h

delta Pmeasurement

purging purging purging purging purging

t