2, 4 and 5-Wire eurofast Receptacles, Front · PDF fileFS .. 4 and 5-Wire eurofast®...
Transcript of 2, 4 and 5-Wire eurofast Receptacles, Front · PDF fileFS .. 4 and 5-Wire eurofast®...
Drawing Number Part Number Lead Specs. Application Pinout
FS 4.2-*
UL, CSA2x22 AWG105°C250 VAC/300 VDC4 A
Mates with 2-pinCordsets
1. N/C2. N/C3. BN4. BU
FS 4.22-*
UL, CSA2x22 AWG105°C250 VAC/300 VDC4 A
Mates with 2-pinCordsets
1. BN2. N/C3. BU4. N/C
FS 4.4-*
UL, CSA4x22 AWG105°C250 VAC/300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FS 4.4-*/S621
UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A
Mates with 4-pin"C" style /S622Cordsets
1. GY12. GY23. GY34. GY4
FS 4.5-*
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordsets 1. BN
2. WH3. BU4. BK5. GYFS 4.5-*/S627
UL, CSA5x20 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
FS 4.5-*/S653
UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD
Mates with 5-pinCordsets,4 conductors PVCfoil shielded withdrain wire to pin 5
1. BN2. WH3. BU4. BK5. Drain
FSN 5-*
UL, CSA5x22 AWG, Drain105°C250 V, 4 A
See pinout
1. GN2. WH3. OG4. BK5. RD
See page B109 for dimensional drawings.* Length in meters. Standard Lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
1
FS(N) ..
2, 4 and 5-Wire eurofast ® Receptacles, Front Mount
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FS 4.6-*
UL, CSA6x22 AWG105°C250 V4 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. Pk
FS 6-*
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. Pk
FS 8-*
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. Ye5. GY6. Pk7. BU8. RD
FS 8.6-*
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. GN3. YE4. GY
5. GN6. N/C7. BU8. N/C
FS 10-*
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with 10-pinCordsets
1. WH2. BN3. GN4. YE5. GY
6. PK7. BU8. RD9. OG10. TN
FS 12-*
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with 12-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK
7. BU8. RD9. OG10. TN11. BK12. VT
See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
1
FS ..
6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount
• Male Receptacles
• NEMA 1, 3, 4, 6P andIEC IP 68 Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FK 4.4-*
UL, CSA4x22 AWG105°C250 VAC/300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FK 4.4-*/S621
UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A
Mates with 4-pin"C" style /S622Cordsets
1. GY12. GY23. GY34. GY4
FK 4.5-*
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordsets 1. BN
2. WH3. BU4. BK5. GYFK 4.5-*/S627
UL, CSA5x20 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
FK 4.5-*/S653
UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD
Mates with 5-pinCordsets,4 conductors PVCfoil shielded withdrain wire to pin5.
1. BN2. WH3. BU4. BK5. Drain
FKN 5-*
UL, CSA5x22 AWG, Drain105°C250 V, 4 A
See pinout
1. GN2. WH3. OG4. BK5. RD
See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
2
FK(N) ..
4 and 5-Wire eurofast ® Receptacles, Front Mount
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FK 4.6-*
UL, CSA6x22 AWG105°C250 V4 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FK 6-*
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FK 8-*
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD
FK 8.6-*
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. GN3. YE4. GY
5. GN6. N/C7. BU8. N/C
FK 10-*
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with 10-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN
FK 12-*
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with 12-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN11. BK12. VT
See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
2
FK ..
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FS 4.4-*/18.25
UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FS 4.4-*/18.25/S613
UL, CSA4x18 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
FS 4.4-*/18.25/S621
UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A
Mates with 4-pin"C" style /S622Cordsets
1. GY12. GY23. GY34. GY4
FS 4.5-*/18.25
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordsets 1. BN
2. WH3. BU4. BK5. GYFS 4.5-*/18.25/S627
UL, CSA5x20 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
FS 4.5-*/18.25/S653
UL, CSA4x22 AWG, Drain105°C250 V , 4 A5.2 mm OD
Mates with 5-pinCordsets,4 conductors PVCfoil shielded withdrain wire to pin 5
1. BN2. WH3. BU4. BK5. Drain
FS 4.5-*/18.25/S621
UL, CSA5x18 AWG105°C250 VAC, 4 A
Mates with 5-pin"C" style /S622Cordsets
1. GY12. GY23. GY34. GY45. GY5
See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
3
FS ..
4 and 5-Wire eurofast ® Receptacles, Front Mount, 1/4-18 NPT Threads
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FS 4.6-*/18.25
UL, CSA6x22 AWG105°C250 V2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FS 6-*/18.25
UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FS 8-*/18.25
UL, CSA8x24 AWG105°C60 VAC/75 VDC,2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD
FS 8-*/18.25/S1505
UL, CSA8x26 AWG105°C60 VAC/75 VDC,2 A
Mates with 8-pinCordsets
FS 8.6-*/18.25
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. GN3. YE4. GY
5. GN6. N/C7. BU8. N/C
FS 10-*/18.25
UL, CSA10x24 AWG105°C60 VAC/75 VDC,2 A
Mates with 10-pinCordsets
1. WH2. BN3. GN4. YE5. GY
6. PK7. BU8. RD9. OG10. TN
FS 12-*/18.25
UL, CSA12x24 AWG105°C60 VAC/75 VDC,2 A
Mates with 12-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK
7. BU8. RD9. OG10. TN11. BK12. VT
See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
3
FS ..
6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, 1/4-18 NPT Threads
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FK 4.4-*/18.25
UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FK 4.4-*/18.25/S613
UL, CSA4x18 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
FK 4.4-*/18.25/S621
UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A
Mates with 4-pin"C" style /S622Cordsets
1. GY12. GY23. GY34. GY4
FK 4.5-*/18.25
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordsets 1. BN
2. WH3. BU4. BK5. GYFK 4.5-*/18.25/S627
UL, CSA5x20 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
FK 4.5-*/18.25/S653
UL, CSA4x22 AWG, Drain105°C250 V , 4 A5.2 mm OD
Mates with 5-pinCordsets,4 conductors PVCfoil shielded withdrain wire to pin 5
1. BN2. WH3. BU4. BK5. Drain
FK 4.5-*/18.25/S621
UL, CSA5x18 AWG105°C250 VAC, 4 A
Mates with 5-pin"C" style /S622Cordsets
1. GY12. GY23. GY34. GY45. GY5
See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
4
FK ..
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
4 and 5-Wire eurofast ® Receptacles, Front Mount, 1/4-18 NPT Threads
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FK 4.6-*/18.25
UL, CSA6x22 AWG105°C250 V4 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FK 6-*/18.25
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FK 8-*/18.25
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD
FK 8-*/18.25/S1505
UL, CSA8x26 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
FK 8.6-*/18.25
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. GN3. YE4. GY
5. GN6. N/C7. BU8. N/C
FK 10-*/18.25
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with 10-pinCordsets
1. WH2. BN3. GN4. YE5. GY
6. PK7. BU8. RD9. OG10. TN
FK 12-*/18.25
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with 12-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK
7. BU8. RD9. OG10. TN11. BK12. VT
See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
4
FK ..
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, 1/4-18 NPT Threads
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FS 4.4-*/14.5
UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FS 4.4-*/14.5/S621
UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A
Mates with 4-pin"C" style /S622Cordsets
1. GY12. GY23. GY34. GY4
FS 4.5-*/14.5
UL, CSA5x22 AWG105°C250 V4 A
Mates with 5-pinCordsets
1. BN2. WH3. BU4. BK5. GY
FS 4.6-*/14.5
UL, CSA6x22 AWG105°C250 V4 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FS 6-*/14.5
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
See page B109 for dimensional drawings.* Length in meters. Standard cable length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
5
FS ..
4, 5, and 6-Wire eurofast ® Receptacles, Front Mount, 1/2-14 NPSM Threads
• Male Receptacles
• NEMA 1, 3, 4, 6P andIEC IP 68 Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FS 8-*/14.5
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD
FS 8.6-*/14.5
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. GN3. YE4. GY5. GN6. N/C7. BU8. N/C
FS 10-*/14.5
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with 10-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN
FS 12-*/14.5
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with 12-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN11. BK12. VT
See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
5
FS ..
8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, 1/2-14 NPSM Threads
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FK 4.4-*/14.5
UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FK4.4-*/14.5/S621
UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A
Mates with 4-pin"C" style /S622Cordsets
1. GY12. GY23. GY34. GY4
FK 4.5-*/14.5
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
1. BN2. WH3. BU4. BK5. GY
FK 6-*/14.5
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FK 8-*/14.5
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE
5. GY6. PK7. BU8. RD
FK 8.6-*/14.5
UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A
Mates with 8-pinCordsets
1. WH2. GN3. YE4. GY
5. GN6. N/C7. BU8. N/C
FK 10-*/14.5
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with 10-pinCordsets
1. WH2. BN3. GN4. YE5. GY
6. PK7. BU8. RD9. OG10. TN
FK 12-*/14.5
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with 12-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK
7. BU8. RD9. OG10. TN11. BK12. VT
See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
6
FK ..
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
4, 5, 6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, 1/2-14 NPSM Threads
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FS 4.2-*/14.5/NPT
UL, CSA2x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 2-pinCordsets
1. N/C2. N/C3. BN4. BU
FS 4.22-*/14.5/NPT
UL, CSA2x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 2-pinCordsets
1. BN2. N/C3. BU4. N/C
FS 4.4-*/14.5/NPT
UL, CSA2x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FS 4.5-*/14.5/NPT
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
1. BN2. WH3. BU4. BK5. GY
FS 4.6-*/14.5/NPT
UL, CSA6x22 AWG105°C250 V4 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FS 6-*/14.5/NPT
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
7
FS .. /14.5/NPT
2, 4, 5 and 6-Wire eurofast ® Receptacles, Front Mount, 1/2-14 NPT Threads
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FS 8-*/14.5/NPT
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD
FS 8.6-*/14.5/NPT
UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A
Mates with 8-pinCordsets
1. WH2. GN3. YE4. GY5. GN6. N/C7. BU8. N/C
FS 10-*/14.5/NPT
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with 10-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN
FS 12-*/14.5/NPT
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with 12-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN11. BK12. VT
See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
7
FS .. /14.5/NPT
8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, 1/2-14 NPT Threads
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FK 4.4-*/14.5/NPT
UL, CSA4x22 AWG105°C300 V, 4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FK 4.5-*/14.5/NPT
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
1. BN2. WH3. BU4. BK5. GY
FK 6-*/14.5/NPT
UL, CSA6x24 AWG105°C250 V, 4 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FK 8-*/14.5/NPT
UL, CSA8x24 AWG105°C250 V, 4 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE
5. GY6. PK7. BU8. RD
FK 8.6-*/14.5/NPT
UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A
Mates with 8-pinCordsets
1. WH2. GN3. YE4. GY
5. GN6. N/C7. BU8. N/C
FK 10-*/14.5/NPT
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with10-pin Cordsets
1. WH2. BN3. GN4. YE5. GY
6. PK7. BU8. RD9. OG10. TN
FK 12-*/14.5/NPT
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with12-pin Cordsets
1. WH2. BN3. GN4. YE5. GY6. PK
7. BU8. RD9. OG10. TN11. BK12. VT
See page B109 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
8
FK .. /14.5/NPT
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
4, 5, 6, 8 10 and 12-Wire eurofast ® Receptacles, Front Mount, 1/2-14 NPT Threads
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FS 4.4-*/13.5 W/LN
UL, CSANickel Plated Brass4x22 AWG105°C250 VAC/300 VDC4 A
Mates with 4-pinCordsets,PG 13.5 Threads
1. BN2. WH3. BU4. BK
FS 4.5-*/13.5 W/LN
UL, CSANickel Plated Brass5x22 AWG105°C250 V4 A
Mates with 5-pinCordsets,PG 13.5 Threads
1. BN2. WH3. BU4. BK5. GY
FS 4.4/18.25
105°CSolder Cup300 VAC/ 250 VDC4 A
Mates with 4-pincordset,1/4 inch 18NPTThreads
N/A
FS 4.4
105°CSolder Cup250 VAC/ 300 VDC4 A
Mates with 4-pincordset,PG 9 Threads
FS 4.5105°CSolder Cup250 V 4 A
Mates with 5-pincordset,PG 9 Threads
N/A
See page B110 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
11
FS ..
9
FS .. /13.5W/LN
10
FS .. /18.25
4 and 5-Wire eurofast ® Receptacles, Front Mount, Leads and Solder Cups
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Cable Application Pinout
FK 4.4/18.25
105°CSolder Cup300 VAC/ 250 VDC4 A
Mates with 4-pincordset,1/4-18NPT Threads
N/A
FK 4.4
105°CSolder Cup250 VAC/ 300 VDC4 A
Mates with 4-pincordset,PG 9 Threads
N/A
FK 4.5
105°CSolder Cup250 V4 A
Mates with 5-pincordset,PG 9 Threads
N/A
See page B110 for dimensional drawings.* Length in meters. Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.
13
FK ..
12
FK .. /18.25
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
4 and 5-Wire eurofast ® Receptacles, Front Mount, Solder Cups
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FS 4.4-*/M20
UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FS 4.5-*/M20
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
1. BN2. WH3. BU4. BK5. GY
FS 6-*/M20
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FS 8-*/M20
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE
5. GY6. PK7. BU8. RD
FS 8.6-*/M20
UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A
Mates with 8-pinCordsets
1. WH2. GN3. YE4. GY
5. GN6. N/C7. BU8. N/C
FS 10-*/M20
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with 10-pinCordsets
1. WH2. BN3. GN4. YE5. GY
6. PK7. BU8. RD9. OG10. TN
FS 12-*/M20
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with 12-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK
7. BU8. RD9. OG10. TN11. BK12. VT
See page B110 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
14
FS .. /M20
4, 5, 6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, M20 Threads
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Cable Application Pinout
FK 4.4-*/M20
UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FK 4.5-*/M20
UL, CSA5x22 AWG105°C250 V4 A
Mates with 5-pinCordsets
1. BN2. WH3. BU4. BK5. GY
FK 6-*/M20
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FK 8-*/M20
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE
5. GY6. PK7. BU8. RD
FK 8.6-*/M20
UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A
Mates with 8-pinCordsets
1. WH2. GN3. YE4. GY
5. GN6. N/C7. BU8. N/C
FK 10-*/M20
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with 10-pinCordsets
1. WH2. BN3. GN4. YE5. GY
6. PK7. BU8. RD9. OG10. TN
FK 12-*/M20
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with 12-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK
7. BU8. RD9. OG10. TN11. BK12. VT
See page B110 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FK.."; "FKV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
15
FK .. /M20
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
4 5, 6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, M20 Threads
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
4, 5, 6, 8, 10 and 12-Wire eurofast ® Receptacles, Front Mount, PG 16 Threads
Drawing Number Part Number Lead Specs. Application Pinout
FS 4.4-*/PG16
UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordset
1. BN2. WH3. BU4. BK
FS 4.5-*/PG16
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordset
1. BN2. WH3. BU4. BK5. GY
FS 6-*/PG16
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordset
1. BN2. WH3. BU4. BK5. GY6. PK
FS 8-*/PG16
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordset
1. WH2. BN3. GN4. YE
5. GY6. PK7. BU8. RD
FS 8.6-*/PG16
UL, CSA6x24 AWG105°C60 VAC/75 VDC,2 A
Mates with 8-pinCordset
1. WH2. GN3. YE4. GY
5. GN6. N/C7. BU8. N/C
FS 10-*/PG16
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with 10-pinCordset
1. WH2. BN3. GN4. YE5. GY
6. PK7. BU8. RD9. OG10. TN
FS 12-*/PG16
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with 12-pinCordset
1. WH2. BN3. GN4. YE5. GY6. PK
7. BU8. RD9. OG10. TN11. BK12. VT
See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FS.."; "FSV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
16
FS .. /PG16
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FKM 4.4-*
UL, CSA4x22 AWG105°C250 VAC/300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FKM 4.5-*
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
1. BN2. WH3. BU4. BK5. GY
FKM 4.5-*/S653
UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD
Mates with 5-pinCordsets,4 Conductors PVCfoil Shielded withDrain Wire topin 5
1. BN2. WH3. BU4. BK5. Drain
FKM 4.6-*
UL, CSA6x22 AWG105°C250 V2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FKM 6-*
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FKM 8-*
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD
See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass.To specify PVC jacketed cable, add "/S717" to the end of the part number.
17
FKM ..
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
4, 5, 6 and 8-Wire eurofast ® Receptacles, with Rotating Coupling Nut
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FSD 4.4-*
UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FSD 4.5-*
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
1. BN2. WH3. BU4. BK5. GY
FSD 4.5-*/S653
UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD
Mates with 5-pinCordsets,4 Conductors PVCfoil Shielded withDrain Wire topin 5
1. BN2. WH3. BU4. BK5. Drain
FSD 6-*
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FSD 8-*
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD
FSD 10-*
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with 10-pinCordsets
1. WH2. BN3. GN4. YE5. GY
6. PK7. BU8. RD9. OG10. TN
FSD 12-*
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with 12-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK
7. BU8. RD9. OG10. TN11. BK12. VT
See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FSD.."; "FSDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
18
FSD ..
4, 5, 6, 8, 10 and 12-Wire eurofast ® Receptacles, with Front Lock Nut
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FKD 4.4-*
UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FKD 4.5-*
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
1. BN2. WH3. BU4. BK5. GY
FKD 4.5-*/S653
UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD
Mates with 5-pinCordsets, 4Conductors PVCfoil Shielded withDrain Wire topin 5
1. BN2. WH3. BU4. BK5. Drain
FKD 6-*
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FKD.."; "FKDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
19
FKD ..
4, 5, and 6-Wire eurofast ® Receptacles, with Front Lock Nut
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FKD 8-*
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD
FKD 10-*
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with 10-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN
FKD 12-*
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with 12-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN11. BK12. VT
See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FKD.."; "FKDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
19
FKD ..
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
8, 10 and 12-Wire eurofast ® Receptacles, with Front Lock Nut
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FSFD 4.4-*
UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FSFD 4.4-*/S621
UL, CSA4x18 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pin"C" style /S622cordsets
1. GY12. GY23. GY34. GY4
FSFD 4.5-*
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
1. BN2. WH3. BU4. BK5. GY
FSFD 4.5-2/S653
UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD
Mates with 5-pinCordsets,4 Conductors PVCFoil Shielded withDrain Wire to pin5
1. BN2. WH3. BU4. BK5. Drain
See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FSFD.."; "FSFDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
20
FSFD ..
4 and 5-Wire eurofast ® Receptacles, Rear Mount with Leads
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FSFD 6-*
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FSFD 8-*
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD
FSFD 8-*/S1505
UL, CSA8x26 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
FSFD 10-*
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with 10-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN
FSFD 12-*
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with 12-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN11. BK12. VT
See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FSFD.."; "FSFDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
20
FSFD ..
6, 8, 10 and 12-Wire eurofast ® Receptacles, Rear Mount with Leads
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FKFD 4.4-*
UL, CSA4x22 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FKFD 4.4-*/S621
UL, CSA4x18 AWG105°C250 VAC/ 300 VDC4 A
Mates with 4-pin"C" style /S622cordsets
1. GY12. GY23. GY34. GY4
FKFD 4.5-*
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
1. BN2. WH3. BU4. BK5. GY
FKFD 4.5-2/S653
UL, CSA4x22 AWG, Drain105°C250 V, 4 A5.2 mm OD
Mates with 5-pinCordsets,4 Conductors PVCFoil Shielded withDrain Wire topin 5
1. BN2. WH3. BU4. BK5. Drain
See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FKFD.."; "FKFDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
21
FKFD ..
4 and 5-Wire eurofast ® Receptacles, Rear Mount with Leads
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Cable Application Pinout
FKFD 6-*
UL, CSA6x24 AWG105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
1. BN2. WH3. BU4. BK5. GY6. PK
FKFD 8-*
UL, CSA8x24 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD
FKFD 8-*/S1505
UL, CSA8x26 AWG105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
FKFD 10-*
UL, CSA10x24 AWG105°C60 VAC/75 VDC2 A
Mates with 10-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN
FKFD 12-*
UL, CSA12x24 AWG105°C60 VAC/75 VDC2 A
Mates with 12-pinCordsets
1. WH2. BN3. GN4. YE5. GY6. PK7. BU8. RD9. OG10. TN11. BK12. VT
See page B111 for dimensional drawings.* Length in meters. Standard lead length is 0.5 meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FKFD.."; "FKFDV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
21
FKFD ..
6, 8, 10 and 12-Wire eurofast ® Receptacles, Rear Mount with Leads
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FSFDL 4.4
Accepts 20 AWGMax Leads105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
FSFDL 4.5
Accepts 20 AWG MaxLeads105°C250 V4 A
Mates with 5-pinCordsets
See page B111 for dimensional drawings.Standard housing material is nickel plated brass "FSFDL.."; "FSFDLV.." indicates 316 stainless steel.
22
FSFDL ..
4 and 5-Wire eurofast ® Receptacles, Rear Mount with Solder Cups
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Cable Application Pinout
FKFDL 4.4
Accepts 20 AWGMax Leads105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
FKFDL 4.5
Accepts 20 AWG MaxLeads105°C250 V, 4 A
Mates with 5-pinCordsets
See page B111 for dimensional drawings.Standard housing material is nickel plated brass "FKFDL.."; "FKFDLV.." indicates 316 stainless steel.
23
FKFDL ..
4 and 5-Wire eurofast ® Receptacles, Rear Mount with Solder Cups
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FSFD 4.4105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
FSFD 4.5105°C250 V, 4 A
Mates with 5-pinCordsets
FSFD 6105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
FSFD 8105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
FSFDK 4.4
Nickel plated brass105°C250 VAC4 A
Mates with 4-pinCordsets, shortpins
FSFDK 4.5
Nickel plated brass105°C250 V, 4 A
Mates with 5-pinCordsets,short pins
See page B112 for dimensional drawings.Standard housing material is nickel plated brass "FSFD.."; "FSFDV.." indicates 316 stainless steel.
25
FSFDK ..
24
FSFD ..
4, 5, 6 and 8-Wire eurofast ® Receptacles, Rear Mount with PCB Pins
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FKFD 4.4105°C250 VAC/ 300 VDC4 A
Mates with 4-pinCordsets
FKFD 4.5105°C250 V, 4 A
Mates with 5-pinCordsets
FKFD 6105°C60 VAC/75 VDC2 A
Mates with 6-pinCordsets
FKFD 8105°C60 VAC/75 VDC2 A
Mates with 8-pinCordsets
FKFDK 4.5
Nickel Plated Brass105°C250 V, 4 A
Mates with 5-pinCordsets,Short pins
See page B112 for dimensional drawings.Standard housing material is nickel plated brass "FKFD.."; "FKFDV.." indicates 316 stainless steel.
27
FKFDK ..
26
FKFD ..
4, 5, 6 and 8-Wire eurofast ® Receptacles, Rear Mount with PCB Pins
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Cable Application Pinout
WFS 4.4-PCB105°C250 VAC/300 VDC4 A
Mates with 4-pinCordsets
WFS 4.5-PCB105°C250 V4 A
Mates with 5-pinCordsets
WFS 6-PCB105°C60 V/75 VDC2 A
Mates with 6-pinCordsets
WFS 8-PCB105°C30 VAC/ 36VDC1.5 A
Mates with 8-pinCordsets
See page B112 for dimensional drawings.Standard Material is nickel plated brass.
4, 5, 6 and 8-Wire eurofast ® Receptacles, Rear Mount with PCB Pins
28
WFS .. PCB
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FS 4.5-PCB105°C250 V4 A
Mates with 5-pinCordsets
FSFDH 4.4105°C250 VAC/300 VDC4 A
Mates with 4-pinCordsets,Separate housingand contact carrier
FSFDH 4.5105°C250 V4 A
Mates with 5-pinCordsets,Separate housingand contact carrier
WFSFDH 4.4105°C250 VAC/300 VDC4 A
Mates with 4-pinCordsets,Separate housingand contactcarrier,right angle
WFSFDH 4.5
105°C250 V4 A
Mates with 5-pinCordsets,Separate housingand contactcarrier,right angle
See page B112 - B113 for dimensional drawings.Standard Material is nickel plated brass.
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
4 and 5-Wire eurofast ® Circuit Board Mounted Receptacles
29
FS .. PCB
30A
WFSFDH ..
30
FSFDH ..
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FK 4.5-PCB105°C250 V4 A
Mates with 5-pinCordsets
FKFDH 4.4
105°C250 VAC/300 VDC4 A
Mates with 4-pinCordsets,separate housingand contact carrier
FKFDH 4.5
105°C250 V4 A
Mates with 5-pinCordsets,separate housingand contact carrier
WFKFDH 4.4105°C250 VAC/300 VDC4 A
Mates with 4-pinCordsets,separate housingand contactcarrier, right angle
WFKFDH 4.5105°C250 V4 A
Mates with 5-pinCordsets,separate housingand contactcarrier, right angle
FKFDHW 4.5
105°C250 V4 A
Mates with 5-pinCordsets,separate housingand contactcarrier, reverse key
See page B113 - B114 for dimensional drawings.Standard Material is nickel plated brass.
4 and 5-Wire eurofast ® Circuit Board Mount Receptacles
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
32
FK .. PCB
31B
FKFDHW ..
31
FKFDH ..
31A
WFKFDH ..
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FSW 4.5-*
UL, CSA4x22, Drain105°C250 V4 A
Mates with 5-pinReverse KeyCordset
1. BN2. WH3. BU4. BK5. GN/YE
FSW 4.5-*/S653
UL, CSA4x22 AWG, Drain105°C250 V4 A
Mates with 5-pinReverse KeyCordset, 4Conductors PVCFoil Shielded withDrain Wire to pin5
1. BN2. WH3. BU4. BK5. Drain
FSW 4.5-*/14.5
UL, CSA4x22, 1x20 AWG105°C250 V4 A
Mates with 5-pinReverse KeyCordset
1. BN2. WH3. BU4. BK5. GN/YE
FSW 4.5-*/14.5/NPT
UL, CSA4x22, 1x20 AWG105°C250 V4 A
Mates with 5-pinReverse KeyCordset
FSDW 4.5-*
UL, CSA4x22, 1x20 AWG,AWM PVC105°C250 V4 A
Mates with 5-pinReverse KeyCordset
1. BN2. WH3. BU4. BK5. GN/YE
See page B109 and 114 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FSW.."; "FSWV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
33
FSW ..
5-Wire eurofast ® Receptacles, Front Mount, Reverse Key
5
FSW .. /14.5
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
35
FSDW ..
34
FSW .. /14.5/NPT
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Cable Application Pinout
FKW 4.5-*
UL, CSA4x22, Drain105°C250 V, 4 A
Mates with 5-pinReverse KeyCordset, PG 9threads
1. BN2. WH3. BU4. BK5. GN/YE
FKW 4.5-*/S653
UL, CSA4x22 AWG, Drain105°C250 V, 4 A
Mates with 5-pinReverse KeyCordset,PG 9 threads,4 Conductors FoilShielded withDrain Wire to pin5
1. BN2. WH3. BU4. BK5. Drain
FKW 4.5-*/14.5
UL, CSA4x22, 1x20 AWG105°C250 V, 4 A
Mates with 5-pinReverse KeyCordset,1/2-14 NPSMthreads
1. BN2. WH3. BU4. BK5. GN/YE
FKMW 4.5-*
UL, CSA4x22, 1x20 AWG105°C250 V, 4 A
Mates with 5-pinReverse KeyCordset, PG 9threads, rotatingcoupling nut
1. BN2. WH3. BU4. BK5. GN/YE
FKDW 4.5-*
UL, CSA4x22, 1x20 AWG,AWM PVC105°C250 V, 4 A
Mates with 5-pinReverse KeyCordset
1. BN2. WH3. BU4. BK5. GN/YE
See page B114 - B115 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass "FKW.."; "FKWV.." indicates 316 stainless steel.To specify PVC jacketed cable, add "/S717" to the end of the part number.
37
FKW .. /14.5
38
FKMW ..
5-Wire eurofast ® Receptacles, Front Mount, Reverse Key
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
36
FKW ..
39
FKDW ..
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Lead Specs. Application Pinout
FSFDW 4.5-*
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinReverse KeyCordset, leads
1. BN2. WH3. BU4. BK5. GN/YE
FSFDLW 4.5
Accepts 20 AWG MaxLeads105°C250 V, 4 A
Mates with 5-pinReverse KeyCordset,solder cup
FSFDW 4.5105°C250 V, 4 A
Mates with 5-pinReverse KeyCordsets, PCB pins
FSFDKW 4.5105°C250 V, 4 A
Mates with 5-pinReverse KeyCordsets,short PCB pins
See page B115 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass.To specify PVC jacketed cable, add "/S717" to the end of the part number.
40
FSFDW ..
41
FSFDLW ..
43
FSFDKW ..
5-Wire eurofast ® Receptacles, Rear Mount, Reverse Key
42
FSFDW ..
• Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Cable Application Pinout
FKFDW 4.5-*
UL, CSA5x22 AWG105°C250 V, 4 A
Mates with 5-pinReverse KeyCordset,leads
1. BN2. WH3. BU4. BK5. GN/YE
FKFDLW 4.5
Accepts 20 AWG MaxLeads105°C250 V, 4 A
Mates with 5-pinReverse KeyCordset,solder cup
N/AFKFDW 4.5105°C250 V, 4 A
Mates with 5-pinReverse KeyCordsets, PCB Pins
FKFDKW 4.5105°C250 V, 4 A
Mates with 5-pinReverse KeyCordsets,short PCB pins
See page B115 - B116 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard housing material is nickel plated brass.To specify PVC jacketed cable, add "/S717" to the end of the part number.
47
FKFDKW ..
46
FKFDW ..
45
FKFDLW ..
44
FKFDW ..
5-Wire eurofast ® Receptacles, Rear Mount, Reverse Key
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Drawing Number Part Number Cable Application Pinout
FKP 4.4-*
UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A
Mates with 4-pinCordsets
1. BN2. WH3. BU4. BK
FKP 4.4-*/S621
UL, CSA4x18 AWG105°C250 VAC/300 VDC4 A
Mates with 4-pin"C" style /S622cordsets
1. GY12. GY23. GY34. GY4
FKP 4.5-*
UL, CSA5x18 AWG105°C250 V, 4 A
Mates with 5-pinCordsets
1. BN2. WH3. BU4. BK5. GY
FKP 4.5-*/S621
UL, CSA5x18 AWG105°C250 V, 4 A
Mates with 5-pin"C" style /S622cordsets
1. GY12. GY23. GY34. GY45. GY5
See page B116 for dimensional drawings.* Length in meters. Standard lead length is 0.5 Meters. Consult factory for other lengths.Standard Material is nickel plated brass.To specify PVC jacketed cable, add "/S717" to the end of the part number.
48
FKP ..
4 and 5-Wire eurofast ® Receptacles, Back Panel Mount
• Female Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Rece
ptac
les
Drawing Number Part Number Lead Specs. Application Pinout
FK FS 4.4/M124-conductor105°C250 V, 4 A
Mates with 4-pinCordsets, for DCApplications
FK FS 4.5/M125-conductor105°C250 V, 4 A
Mates with 5-pinCordsets, for DCApplications
FKW FSW 4.5/M125-conductor105°C250 V, 4 A
Mates with 5-pinReverse KeyCordsets, for DCApplications
FK FS 4.6/M126-conductor105°C36 V, 1.5 A
Mates with 6-pinCordsets, for DCApplications
FK FS 6/M126-conductor105°C36 V, 1.5 A
Mates with 6-pinCordsets, for DCApplications
FK FS 8/M128-conductor105°C36 V, 1.5 A
Mates with 8-pinCordsets, for DCApplications
See page B116 for dimensional drawings.Standard housing material is nickel plated brass "FK FS.."; "FKV FSV.." indicates 316 stainless steel.
• Female to Male Receptacles
• NEMA 1, 3, 4, 6P and IEC IP 68Protection
4, 5, 6 and 8-Wire eurofast ® Feed-Thru Receptacles
49
FK FS .. /M12
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]