Contents 0
2
2 - Zelio Time - timing relays
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/2
� Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/4
� Choice, functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/6
Modular relays, solid state output,width 17.5 mm� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/14
� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/16
Industrial single or multifunction relays, solid state output, width 22.5 mm� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/18
� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/20
Modular relays, relay output, width 17.5 mm� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/22
� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/24
Industrial single, dual or multifunction relays, relay output, width 22.5 mm� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/28
� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/30
Industrial single-function, relays, optimum, relay output, width 22.5 mm� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/42
� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/44
Universal plug-in relays, relay output, width 35 mm� Plug-in relays 11-pin
� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/48
� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/50
� Plug-in relays 8-pin
� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/52
� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/54
Miniature plug-in relays, relay output� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/56
� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/57
Electronic relays, relay output, 48 x 48 housing� Presentation, description, characteristics, functions . . . . . . . . . . . . . . . page 2/58
� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2/63
Panel-mounted, plug-in, universal relays� Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 2/66 and 2/70
� References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 2/69 and 2/71
2/2
2
Selection guide 2 Zelio Time - timing relays 2
Applications These timing relays enable simple automation cycles to be set up using wired logic.They can also be used to complement the functions of PLCs.
Output Solid stateTiming relays with solid state output reduce the amount of wiring required (wired in series). The durability of these timing relays is independent of the number of operating cycles.
RelayRelay outputs provide complete isolation between the supply and outut circuits.It is possible to have several output circuits.
Type Modular Industrial Modular Industrial
Timing ranges 7 ranges :1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h
1 or 2 ranges,depending on model :10 s, 30 s, 300 s, 60 min
Depending on model :6 ranges :1 s, 10 s, 1 min, 10 min, 1 h, 10 h7 ranges :1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h
Depending on model :4 ranges :0.6 s, 2.5 s, 20 s, 160 s7 ranges :1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h7 ranges :1 s, 3 s, 10 s, 30 s, 100 s, 300 s, 10 min10 ranges :1 s, 3 s, 10 s, 30 s, 100 s, 300 s, 30 min, 300 min, 30 h, 300 h
Relay type RE11 L���� RE9 RE11 R���� RE 88 865 ���
RE7Pages 2/16 and 2/17 2/20 2/24 to 2/27 2/30 to 2/33
and 2/36 to 2/39
2/3
2
22
These timing relays enable simple automation cycles to be set up using wired logic.They can also be used to complement the functions of PLCs.
RelayRelay outputs provide complete isolation between the supply and output circuits.It is possible to have several output circuits.
Optimum Plug-in Panel-mounted
Universal Miniature Analogue Digital
1 range,depending on model :0.5 s, 3 s, 10 s, 30 s, 300 s, 30 min
7 ranges :1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h
7 ranges :0,1 s...1 s1 s...10 s0,1 min...1 min1 min...10 min0,1 h...1 h1 h...10 h10 h...100 h
14 ranges :1,2 s, 3 s, 12 s, 30 s, 120 s, 300 s, 12 min, 30 min, 120 min, 300 min, 12 h, 30 h, 120 h, 300 h
Depending on model :7 ranges :99.99 s, 999.99 s, 99 min 59 s, 99.99 min, 999.9 min,99 h 59 min, 999.9 h11 ranges :99.99 s, 999.99 s, 9999 s, 99 min 59 s, 99.99 min,999.9 min, 9999 min,99 h 59 min, 99,99 h,999.9 h, 9999 h
RE8 RE 88 867 ��� RE XL�TM�� RE 48A ��� RE 88 857 ���
2/44 to 2/47 2/48 to 2/55 2/56 and 2/57 2/58 to 2/65 2/66 to 2/71
2/4
2
Presentation 2 Zelio Time - timing relays 2
PresentationA timing relay is a component which is designed for timing events in industrial automation systems by closing or opening contacts before, during or after a set timing period.
There are two main 'families' of timing relays: � “DIN rail mounted” relays (RE7, RE8, RE9, RE11, RE XL…) designed for mounting on DIN rails in an enclosure,
� “Panel mounted” relays type RE 48A, designed for mounting on the front of a panel to give users easy access to the settings.
These relays have one, two or four outputs. Sometimes the second output can be either timed or instantaneous.If the power is switched off during the timing period, the relay reverts to its initial position.
Application examples:� opening of automatic doors,� alarm,� lighting in toilets,� car park barriers ...
Definitions The following definitions will assist in understanding the operation of these relays: � Relay output:This is the most common type of output. When the relay is energised, the moving armature is attracted by the coil and so actuates the contacts, which change state. When the relay is de-energised, both the armature and the contacts revert to their initial position.This type of output allows complete isolation between the supply and the output.
There are three types of output: ��C/O: changeover contact, i.e. when the relay is de-energised, the circuit between the common point C and N/C is closed and when the relay is operating (coil energised), it closes the circuit between the common point C and N/O.
��N/C: a contact that is closed without being actuated is called a Normally Closed (N/C) contact.
��N/O: a contact that closes when actuated is called a Normally Open (N/O) contact.
� Solid state output:These outputs are entirely electronic and involve no moving parts; service life is therefore increased.
� Breaking capacity:The current value that a contact is capable of breaking in specified conditions.
� Mechanical durability:The number of mechanical operating cycles of the contact or contacts.
� Minimum switching capacity (or minimum breaking capacity): corresponds to the minimum required current which can flow through the contacts of a relay.
� G (Gate) input : Gate input allows timing in progress to be interrupted without resetting it.
RE11
5219
31-1
2-M
RE7 RL13BU
5609
04
RE 48A
5219
38-4
4-M
RE XL
5325
35
CNO
NC
NC
NO
2/5
2
Presentation (continued) 2 Zelio Time - timing relays 2
Definitions (continued)Functions
Timing functions are identified by letters.Main timing functions
Complementary functions (1)
Definitions
A (2) Delay on energisation
Ac Timing after closing and opening of control contact
Ad Timing on closing of control contact
Ah Flashing single cycle by operation of control contact
Ak Asymmetrical On-delay and Off-delay with external control
At Delay on energisation with memory
Aw Off-delay on energisation or on opening of control contact
B (2) Timing on impulse, one shot
Bw Pulse output (width adjustable)
C (2) Timing after opening of control contact
D (2) Symmetrical flashing, start with output in rest position
Di (2) Symmetrical flashing, start with output in operating position
H (2) Timing on energisation
He Pulse-on de-energisation
Ht Timing on energisation with memory
K Delay on de-energisation (without auxiliary supply)
L (2) Asymmetrical flashing, start with output in rest position
Li (2) Asymmetrical flashing, start with output in operating position
Lt Asymmetrical flashing with partial stop of timing
N Safe-guard
O Delayed safe-guard
P Delayed fixed-length pulse
Pt Impulse counter (on-delay)
Qc Star-delta timing
Qe Star-delta timing
Qg Star-delta timing
Qt Star-delta timing
T Bistable relay
Tt Timed impulse relay
W On-delay after opening of control contact
(1) Complementary functions enhance the main timing functions.Example: Ac: timing after closing and opening of control contact.
(2) The most commonly used timing functions.
2/6
2
Selection 2 Zelio Time - timing relays 2
Selection tableSelection criteria� Functions (On-delay or Off-delay, counter, flashing…)� Supply voltage (example: �/� 12 V…240 V).� Timing range (example: 0.05 s…100 h)� Type of output (contact or solid state) and required Number of contacts.� Breaking capacity or Rated current of contacts, expressed in Amperes.This is the maximum current which may flow through the contacts.
Functions Supply voltage Timing range Type of output Rated current
Relay Page
A � 12 V 0.1 s…100 h 2 C/O contacts 5 A RE XL2TMJD 2/57
0.1 s …100 h 4 C/O contacts 3 A RE XL4TMJD 2/57� 24 V 0.1 s…100 h 2 C/O contacts 5 A RE XL2TMBD 2/57
0.1 s…100 h 4 C/O contacts 3 A RE XL4TMBD 2/57
� 24 V 0.1 s…100 h 2 C/O contacts 5 A RE XL2TMB7 2/570.1 s…100 h 4 C/O contacts 3 A RE XL4TMB7 2/57
� 120 V 0.1 s…100 h 2 C/O contacts 5 A RE XL2TMF7 2/57
0.1 s…100 h 4 C/O contacts 3 A RE XL4TMF7 2/57� 230 V 0.1 s…100 h 2 C/O contacts 5 A RE XL2TMP7 2/57
0.1 s…100 h 4 C/O contacts 3 A RE XL4TMP7 2/57
�/� 24…240 V 0.1 s…10 s 1 solid state output 0.7 A RE9 TA11MW 2/200.3 s…30 s 0.7 A RE9 TA31MW 2/203 s…300 s 0.7 A RE9 TA21MW 2/20
40 s…60 min 0.7 A RE9 TA51MW 2/201 s…100 h 0.7 A RE11 LA MW 2/160.02 s…300 h 2 timed C/O contacts 5 A RE 48A TM12 MW 2/58
�/� 24 V, � 110…240 V 0.05 s…300 h 1 C/O contact 8 A RE7 TL11BU 2/360.1 s…3 s 8 A RE8 TA61BUTQ 2/440.1s…10 s 8 A RE8 TA11BUTQ 2/44
0.3 s…30 s 8 A RE8 TA31BUTQ 2/443 s…300 s 8 A RE8 TA21BUTQ 2/4420…30 min 8 A RE8 TA41BUTQ 2/44
�/� 24 V, � 110…240 V, �/� 42…48 V
0.05 s…300 h 2 C/O contacts 8 A RE7 TP13BU 2/38
A, Ac, At, B, Bw, C, D, Di, H, Ht � 24…240 V 1 s…100 h 1 solid state output 0.7 A RE11 LM BM 2/17�/� 12 V 1 s…100 h 1 C/O contact 8 A RE11 RM JU 2/27�/� 12…240 V 1 s…100 h 1 C/O contact 8 A RE11 RM MW 2/26
1 s…100 h 8 A RE11 RM MWS 2/27� 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RM MU 2/26
A, At � 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RA MU 2/24
A, At, Aw � 110…240 V, �/� 24 V, �/� 42…48 V
0.05 s…300 h 1 C/O contact 8 A RE7 TM11BU 2/36
A, At, B, C, D, Di, H, Ht � 24 V, � 24…240 V 1 s…10 h 1 C/O contact 5 A RE11 RME MU 2/27
A, B, C, Di �/� 24…240 V 0.02 s…300 h 2 timed C/O contacts 5 A RE 48A ML12 MW 2/63
A, C, D, Di, H, Qg, Qt, W � 110…240 V, �/� 24 V, �/� 42…48 V
0.05 s…300 h 2 C/O contacts 8 A RE7 MY13BU 2/39
�/� 24…240 V 0.05 s…300 h 2 C/O contacts 8 A RE7 MY13MW 2/39
A, C, D, Di, H, W � 110…240 V, �/� 24 V, �/� 42…48 V
0.05 s…300 h 1 C/O contact 8 A RE7 ML11BU 2/36
A, D, Di, H �/� 24…240 V� 24…240 V
0.1 s…10 s et 3 s…300 s
1 solid state output 0.7 A RE9 MS21MW 2/20
A1, A2, H1, H2 �/� 24…240 V 0.02 s…300 h 2 C/O contacts 5 A RE 48A MH13 MW 2/63
Ac � 110…240 V, �/� 24 V, �/� 42…48 V
0.05 s…300 h 1 C/O contact 8 A RE7 MA11BU 2/360.05 s…300 h 2 C/O contacts 8 A RE7 MA13BU 2/38
Ad, Ah, N, O, P, Pt, TI, Tt, W � 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RMX MU 2/27
Ak � 110…240 V, �/� 24 V, �/� 42…48 V
0.05 s…300 h 1 C/O contact 8 A RE7 MV11BU 2/36
2/7
2
Selection (continued) 2 Zelio Time - timing relays 2
Selection table (continued)Functions Supply voltage Timing range Type of output Rated
currentRelay Page
B � 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RB MU 2/25
C �/� 24 V 0.1 s…10 s 1 C/O contact 8 A RE8 RA11BTQ 2/440.3 s…30 s 8 A RE8 RA31BTQ 2/443 s…300 s 8 A RE8 RA21BTQ 2/44
� 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RC MU 2/25� 110…240 V 0.1 s…10 s 1 C/O contact 8 A RE8 RA11FUTQ 2/44
0.3 s…30 s 8 A RE8 RA31FUTQ 2/44
3 s…300 s 8 A RE8 RA21FUTQ 2/4420 s…30 min 8 A RE8 RA41FUTQ 2/44
�/� 24 V, � 110…240 V, �/� 42…48 V
0.05 s…300 h 1 C/O contact 8 A RE7 RA11BU 2/37
0.05 s…300 h 8 A RE7 RM11BU 2/370.05 s…300 h 2 C/O contacts 8 A RE7 RL13BU 2/38
� 24…240 V 0.1 s…10 s 1 solid state output 0.7 A RE9 RA11MW7 2/20
0.3 s…30 s 0.7 A RE9 RA31MW7 2/203 s…300 s 0.7 A RE9 RA21MW7 2/2040 s…60 min 0.7 A RE9 RA51MW7 2/20
1 s…100 h 0.7 A RE11 LC BM 2/17D �/� 24 V, � 110…240 V 0.05 s…300 h 1 C/O contact 8 A RE7 CL11BU 2/37
0.1 s…10 s 8 A RE8 CL11BUTQ 2/45
�/� 24 V, � 110…240 V, �/� 42…48 V
0.05 s…300 h 2 C/O contacts 8 A RE7 CP13BU 2/39
H �/� 24 V, � 110…240 V 0.05 s…300 h 1 C/O contact 8 A RE7 PE11BU 2/370.1 s…10 s 8 A RE8 PE11BUTQ 2/460.3 s…30 s 8 A RE8 PE31BUTQ 2/46
3 s…300 s 8 A RE8 PE21BUTQ 2/46�/� 24 V, � 110…240 V, �/� 42…48 V
0.05 s…300 h 2 C/O contacts 8 A RE7 PP13BU 2/39
� 24…240 V 1 s…100 h 1 solid state output 0.7 A RE11 LH BM 2/16H, Ht � 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RH MU 2/24
He �/� 24 V, � 110…240 V 0.05 s…0.5 s 1 C/O contact 8 A RE8 PT01BUTQ 2/47
K �/� 24…240 V 0.05 s…10 min 1 C/O contact 5 A RE7 RB11MW 2/37
�/� 24 V, � 110…240 V 0.05 s…0.5 s 1 C/O contact 8 A RE8 RB51BUTQ 2/450.1 s…10 s 8 A RE8 RB11BUTQ 2/450.3 s…30 s 8 A RE8 RB31BUTQ 2/45
�/� 24…240 V 0.05 s…10 min 2 C/O contacts 5 A RE7 RB13MW 2/38L, Li � 24 V, � 24…240 V 1 s…100 h 1 C/O contact 8 A RE11 RL MU 2/25
� 24…240 V 1 s…100 h 1 solid state output 0.7 A RE11 LL BM 2/17
�/� 12 V 1 s…100 h 1 C/O contact 8 A RE11 RL JU 2/25�/� 24…240 V 0.02 s…300 h 2 timed C/O contacts 5 A RE 48A CV12 MW 2/63
L, Li, Lt � 110…240 V, �/� 24 V, �/� 42…48 V
0.05 s…300 h 1 C/O contact 8 A RE7 CV11BU 2/37
Qc �/� 24 V, � 110…240 V 0.1 s…10 s 1 C/O contact 8 A RE8 YG11BUTQ 2/47
0.3 s…30 s 8 A RE8 YG31BUTQ 2/473 s…300 s 8 A RE8 YG21BUTQ 2/47
Qe �/� 24 V 0.3 s…30 s 1 NO + 1 NC 8 A RE8 YA32BTQ 2/47
� 110…240 V 0.3 s…30 s 1 NO + 1 NC 8 A RE8 YA32FUTQ 2/47� 380…415 V 0.3 s…30 s 1 NO + 1 NC 8 A RE8 YA32QTQ 2/47
Qg �/� 24 V, � 110…240 V, �/� 42…48 V
0.05 s…300 h 1 NO + 1 NC 8 A RE7 YR12BU 2/39
Qt �/� 24 V, � 110…240 V, �/� 42…48 V
0.05 s…300 h 2 C/O contacts 8 A RE7 YA12BU 2/39
W �/� 24 V 0.1 s…10 s 1 C/O contact 8 A RE8 PD11BTQ 2/46
0.3 s…30 s 8 A RE8 PD31BTQ 2/463 s…300 s 8 A RE8 PD21BTQ 2/46
� 110…240 V 0.1 s…10 s 1 C/O contact 8 A RE8 PD11FUTQ 2/46
0.3 s…30 s 8 A RE8 PD31FUTQ 2/463 s…300 s 8 A RE8 PD21FUTQ 2/46
�/� 24 V, � 110…240 V, �/� 42…48 V
0.05 s…300 h 2 C/O contacts 8 A RE7 PD13BU 2/39
W, Ht �/� 24 V, � 110…240 V, �/� 42…48 V
0.05 s…300 h 1 C/O contact 8 A RE7 PM11BU 2/37
2/8
2
Functions 2 Zelio Time - timing relays 2
FunctionsU : SupplyR : Relay or solid state outputR1/R2 : 2 timed outputsR2 inst. :The second output is instantaneous if the right position is selectedT : Timing periodC : Control contactG : GateTa : Adjustable On-delayTr : Adjustable Off-delay
Function diagram:Relay de-energised
Relay energised
Output open
Output closed
Function A : Delay on energisation1 output 2 outputs
The timing period T begins on energisation.After timing, the output(s) R close(s).The second output can be either timed or instantaneous.
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).
Function Ac: Timing after closing and opening of control contact1 output 2 outputs
After power-up, closing of the control contact C causes the timing period T to start (timing can be interrupted by operating the Gate control contact G). At the end of this timing period, the relay closes.When control contact C re-opens, the timing T starts.At the end of this timing period T, the output reverts to its initial position (timing can be interrupted by operating the Gate control contact G).The second output can be either timed or instantaneous.
T = t1 + t2 + …T = t’1 + t’2 + …
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).
Function Ad: Timing on closing of control contact.
After power-up, pulsing or maintaining of control contact C starts the timing T. At the end of this timing period T, the output R closes. The output R will be reset the next time control contact C is pulsed or maintained.
Function Ah: Flashing single cycle by operation of control contact
After power-up, pulsing or maintaining of control contact C starts the timing T.A single cycle then starts with 2 timing periods T of equal duration (start with output in rest position)Output R closes at the end of the first timing period T and reverts to its initial position at the end of the second timing period T.Control contact C must be reset in order to re-start the single flashing cycle.
U
R
T
U
R1/R2
TR2 inst.
U
C
t1
G
R
t'1t2 t'2
U
C
R1/R2
T T
R2 inst.
U
R
C
T T
U
R
C
TT T T
2/9
2
Functions (continued) 2 Zelio Time - timing relays 2
Function Ak: Asymmetrical On-delay and Off-delay with external control
After power-up and closing of the control contact C, timing starts for a period Ta (timing can be interrupted by operating the Gate control contact G).At the end of this timing period Ta, the output R closes.Opening of control contact C causes a second timing period Tr to start (timing can be interrupted by operating the Gate control contact G).At the end of this timing period Tr, the output R reverts to its initial state.
Ta = t1 + t2 + …Tr = t’1 + t’2 + …Function At: Delay on energisation with memory
After power-up, the first opening of control contact C starts the timing. Timing can be interrupted each time control contact C closes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output relay closes.
T = t1 + t2 + …Function Aw: Off-delay on energisation or on opening of control contact
The timing period T starts on energisation.At the end of the timing period T, the output R closes.Closing of the control contact C makes the output R open. Opening of control contact C restarts timing period T.At the end of timing period T, the output R closes.
Function B: Timing on impulse, one shot
After power-up, pulsing or maintaining control contact C starts the timing T.The output R closes for the duration of the timing period T then reverts to its initial state.
Function Bw: Pulse output (width adjustable)
On closing and opening of control contact C, the output R closes for the duration of the timing period T.
U
C
t1
G
R
t'1t2 t'2
U
R
C
t1 t2
U
R
C
T T
U
R
C
T T
U
R
C
T T
2/10
2
Functions (continued) 2 Zelio Time - timing relays 2
Function C: Timing after opening of control contact1 output 2 outputs
After power-up and closing of the control contact C, the output R closes.When control contact C re-opens, timing T starts.At the end of the timing period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).
Function D: Symmetrical flashing, start with output in rest position1 output 2 outputs
Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.The second output can be either timed or instantaneous.
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).
Function Di: Symmetrical flashing, start with output in operating position1 output 2 outputs
Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.The second output can be either timed or instantaneous.
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).
Function H: Timing on energisation1 output 2 outputs
On energisation of the relay, timing period T starts and the output(s) R close(s).At the end of the timing period T, the output(s) R revert(s) to its/their initial state.The second output can be either timed or instantaneous.
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).
U
C
R
T
U
R1/R2
C
TR2 inst.
T T T T T T
U
R
U
R1/R2
T T T T T TR2 inst.
T T T T T
U
R
U
R1/R2
T T T T TR2 inst.
U
R
T
U
R1/R2
TR2 inst.
2/11
2
Functions (continued) 2 Zelio Time - timing relays 2
Function He: Pulse-on de-energisation
On de-energisation, the output R closes for the duration of a timing period T.
Function Ht: Timing on energisation with memory
On energisation, the output R closes for the duration of a timing period T then reverts to its initial state.Pulsing or maintaining control contact C will again close the output R.Timing T is only active when control contact C is released and so the output R will not revert to its initial state until after a time t1 + t2 + … .The relay memorises the total, cumulative opening time of control contact C and, once the set time T is reached, the output R reverts to its initial state.
T = t1 + t2 + …Function K: Delay on de-energisation (without auxiliary supply)1 output 2 outputs
On energisation, the output(s) R close(s).On de-energisation, timing period T starts and, at the end of this period, the output(s) R revert(s) to its/their initial state.
Function L: Asymmetrical flashing, start with output in rest position
Repetitive cycle comprises of two, independently adjustable timing periods Ta and Tr. Each timing period corresponds to a different state of the output R.
Function Li: Asymmetrical flashing, start with output in operating position
Repetitive cycle comprises of two, independently adjustable timing periods Ta and Tr. Each timing period corresponds to a different state of the output R.
Function Lt: Asymmetrical flashing with partial stop of timing
Repetitive cycle comprises of two, independently adjustable timing periods Ta and Tr. Each timing period corresponds to a different state of the output R.Gate control contact G can be operated to partially stop timing periods Ta and Tr.
Tr = t1 + t2 + … Ta = t’1 + t’2 + …
U
R
> 80 ms 80 msT < T
U
R
C
t1 t2T
U
R
T
U
R1
R2
T
Tr Ta
U
R
Ta Tr
U
R
R
G
t1 t'2t2 t'1
U
2/12
2
Functions (continued) 2 Zelio Time - timing relays 2
Function N: Safe-guard
After power-up and an initial control pulse C, the output R closes.If the interval between two control pulses C is greater than the set timing period T, timing elapses normally and the output R closes at the end of the timing period. If the interval is not greater than the set timing period, the output R remains closed until this condition is met.
Function O: Delayed safe-guard
An initial timing period T begins on energisation. At the end of this timing period, the output R closes. As soon as there is a control pulse C, the output R reverts to its initial state and remains in that state until the interval between two control pulses is less than the value of the set timing period T. Otherwise, the output R closes at the end of the timing period T.
Function P: Delayed fixed-length pulse
The timing period T begins on energisation.At the end of this period, the output R closes for a fixed time P.
Function Pt: Impulse counter (on-delay)
On energisation, timing period T starts (it can be interrupted by operating the Gate control contact G).At the end of this period, the output R closes for a fixed time P.
Function Qc: Star-delta timing
On energisation, the star contact closes instantaneously and timing starts. At the end of the timing period, the star contact opens.After a 50 ms pause, the delta contact closes and remains in this position.
Function Qe: Star-delta timing
Timing for star-delta starter with contact for switching to star connection.
T
U
C
R
T T T
U
C
Rt<T
U
R
T P
P = 500 ms
t1 t2 P
U
G
R
T = t1 + t2 + …P = 500 ms
T 50 ms
U
R
T 80 ms
U
R1
R2
2/13
2
Functions (continued) 2 Zelio Time - timing relays 2
Function Qg: Star-delta timing
Timing for star-delta starter with contact for switching to star connection.
Function Qt: Star-delta timing
Timing for star-delta starter with double On-delay period.
Function T: Bistable relay
After power-up, pulsing or maintaining of control contact C switches the output on.A second pulse on the control contact C switches the output R off.
Function Tt: Timed impulse relay
After power-up, pulsing or maintaining of control contact C switches output R on and starts timing T.The output switches off at the end of the timing period T or following a second pulse on the control contact C.
Function W: On-delay after opening of control contact1 output 2 outputs
After power-up and opening of the control contact, the output(s) close(s) for a timing period T.At the end of this timing period the output(s) revert(s) to its/their initial state.The second output can be either timed or instantaneous.
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).
T T
50 ms
U
R1
R2
U
R1
R2
T T
50 ms
U
C
R
U
C
R
T t<T
T
U
C
R
U
C
R1/R2
TR2 inst.
2/14
2
Characteristics 2 Zelio Time -modular timing relays 2
Relays with solid state output, width 17.5 mm
Timing characteristicsSelectable timing rangesby selector switch on front panel
s 0.1…1 1…10
min 0.1…1
1…10h 0.1…1
1…10
10…100Repeat accuracy(with constant parameters)
Conforming to IEC 61812-1 ± 0.5 %
Drift Temperature ± 0.05 % / °CVoltage ± 0.2 % / V
Setting accuracy at full scale
Conforming to IEC 61812-1 ± 10 % at 25 °C
Minimum duration of control pulse
Typical ms 50
Maximum reset time by de-energisation
Typical ms 350
Immunity to microbreaks Typical ms > 10
Supply characteristicsSupply voltage
VDepending on version:� 24…240�/��24…240
Frequency Hz 50/60
Operating range 85…110 % UnOn-load factor 100 %
Maximum power consumption
Depending on model
� 24 V W 0.6
� 240 V W 1.5 � 240 V VA 32
Output characteristicsOutput type Solid state
Breaking capacity A �/��0.7 at 20° C (0.5 A UL)
Derating mA 5 / °CMaximum permissible current A 20 ≤ 10 ms
Minimum breaking current mA 10 Leakage current mA < 5
Maximum switching voltage V �/��250
Typical voltage drop at terminals 3-wire 4 V - 2-wire 8 V
Electrical life 108 operationsMechanical life 108 operations
Dielectric strength Conforming to IEC 60664, IEC 60255-5
kV 2.5...1 mA / 1 min
Input characteristicsInput type Volt-free contact (no potential)
Control possible by 3-wire sensor with PNP output, maximum residual voltage: 0.4 V whatever the supply voltage of the timer
References :pages 2/16 and 2/17
Dimensions :page 2/16
Schemes :page 2/17
2/15
2
Characteristics (continued) 2 Zelio Time -modular timing relays 2
Relays with solid state output, width 17.5 mm
General characteristicsConforming to standards IEC 61812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC
(� marking) + EMC directive (89/336/EEC + IEC 60669-2-3)
Approvals cULus, CSAAmbient air temperature around the device
Storage °C - 30…+ 60
Operation °C - 20…+ 60Creepage distance and clearance
Conforming to IEC 60664-1 kV 4 kV/3
Degree of protectionconforming to IEC 60529
Terminal block IP 20Housing IP 40
Front panel IP 50
Vibration resistance Conforming to IEC 60068-2-6 f = 10…55 HzA = 0.35 mm
Relative humidity without condensation
Conforming to IEC 60068-2-3 93 %
Electromagnetic compatibility
Immunity to electrostatic discharge, conforming to IEC 61000-4-2
Level III (Air 8 kV/Contact 6 kV)
Immunity to electromagnetic fields,conforming to ENV 50140/204 (IEC 61000-4-3)
Level III (10 V/m: 80 MHz…1 GHz)
Immunity to fast transients in bursts, conforming to IEC 61000-4-4
Level III (direct 2 kV / capacitive connecting clip 1 kV)
Immunity to surges on the power supply, conforming to IEC 61000-4-5
Level III (common mode 2 kV / differential mode 1 kV)
Immunity to radio frequency interference in common mode,conforming to ENV 50141 (IEC 61000-4-6)
Level III (10 V rms: 0.15…80 MHz)
Immunity to voltage dips and breaks,conforming to IEC 61000-4-11
30 % / 10 ms
60 % / 100 ms95 % / 5 s
Radiated and mains conducted disturbance,conforming to EN 55022 (EN 55011 Group 1)
Class B
Fixing Symmetrical mounting rail (EN 50022)
mm 35
Clamping capacity Without cable end mm2 2 x 2.5 or 1 x 4With cable end mm2 2 x 1.5
Housing material Self-extinguishing
References :pages 2/16 and 2/17
Dimensions :page 2/16
Schemes :page 2/17
2/16
2
Functions,references,dimensions,schemes 2
Zelio Time -modular timing relays 2
Relays with solid state output, width 17.5 mm
Solid state output� Multifunction, dual function or single function� Multi-range (7 selectable ranges)� Multivoltage� Solid state output: 0.7 A� Screw terminals
Function diagramsFunction A Function H
Delay on energisation
Timing on energisation
References
Functions Single function Single functionA H
Timing ranges 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 hVoltages � 24…240 V – RE11 LH BM
�/� 24…240 V RE11 LA MW –Nominal output current 0.7 A 0.7 AConnection Screw terminals � �
Weight (kg) 0.060 0.060
Dimensions and connection schemesDimensions
U
RT
U
R
C
t1 t2T
5219
25
5219
25
5,5
72
17,9
81
Characteristics :pages 2/14 and 2/15
Schemes :page 2/17
2/17
2
22
Function At Function B Function C Function L Function LiDelay on energisation with memory
T = t1 + t2 + …
Timing on impulse, one shot
Timing after opening of control contact
Asymmetrical flashing, start with output in rest position
Asymmetrical flashing, start with output in operating position
Function Ht Function D Function Di Function Ac Function BwTiming on energisation with memory
T = t1 + t2 + …
Symmetrical flashing, start with output in rest position
Symmetrical flashing, start with output in operating position
Timing after closing and opening of control contact
Pulse output (width adjustable)
Single function Dual function MultifunctionC L - Li A - At - B - C - H - Ht - D - Di - Ac - Bw
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 hRE11 LC BM RE11 LL BM RE11 LM BM– – –
0.7 A 0.7 A 0.7 A� � �
0.060 0.060 0.060
Connection schemesSingle function relay Multifunction relay Flashing
Functions A, H Function C
(1) Contact Y1 :- Control for functions B, C, Ac, Bw.- Partial stop for functions At, Ht.- Function D if Di selected.- Not used for functions A and H.
Functions L, Li
(1) Link A2-Y1 for function L only.
U
R
C
t1 t2
U
R
C
T T
U
C
RT
Tr Ta
U
RTa Tr
U
R
U
R
C
t1 t2T
T T T T T T
U
RT T T T T
U
R
U
C
RT T
U
R
C
T T
5219
26
5219
27
5219
28
R
A2/
LA
1
U
±
±
R
LA
1
U
±
±
A2 Y2
Y2
R
A2 Y1
18A
1
U
Y1(1)
a/c
a/c
(1)
R
A2 Y1
18A
1
U
Characteristics :pages 2/14 and 2/15
Dimensions :page 2/16
2/18
2
Characteristics 2 Zelio Time -industrial timing relays 2
Single or multifunction relays, solid state output,width 22.5 mm
The RE9 range of relays is designed for simple, repetitive applications with short and intensive cycles because their solid state output provides very high electrical durability.Each relay has a single timing range.Each relay has a wide voltage range from 24 to 240 V.The range comprises 9 references with 3 model types:� RE9 TA: function A,� RE9 RA: function C,� RE9 MS: multifunction A, H, L, Li.These products have a transparent, hinged flap on their front face to avoid any accidental alteration of the settings. This flap can be directly sealed.
Presentation
5608
53
EnvironmentConforming to standards IEC 61812-1, EN 61812-1
Product certifications CSA, GL pending. UL
��������marking Zelio Time timing relays conform to European regulations relating to � marking
Ambient air temperaturearound the device
Storage °C - 40…+ 85
Operation °C - 20…+ 60Permissible relative humidity range
Conforming to IEC 60721-3-3 15…85 % Environmental class 3K3
Vibration resistance Conforming to IEC 60068-2-6, 10 to 55 Hz
a = 0.35 ms
Shock resistance Conforming to IEC 60068-2-27 15 gn - 11 ms
Degree of protection Casing IP 50Terminals IP 20
Degree of pollution Conforming to IEC 60664-1 3
Overvoltage category Conforming to IEC 60664-1 III
Rated insulation voltage Conforming to IEC V 250Conforming to CSA V 300
Test voltage for insulation tests
Dielectric test kV 2.5 Shock wave kV 4.8
Voltage limits Power supply circuit 0.85…1.1 Uc
Frequency limits Power supply circuit Hz 50/60 ± 5 %
Disconnection value Power supply circuit > 0.1 Uc
Mounting positionwithout derating
In relation to normal vertical mounting plane
Any position
CablingMaximum c.s.a.
Flexible cable without cable end mm2 2 x 2.5
Flexible cable with cable end mm2 2 x 1.5
Tightening torque N.m 0.6…1.1
Immunity to electromagnetic interference (EMC) (application class 2 conforming to EN 61812-1)Electrostatic discharge Conforming to IEC 61000-4-2 Level 3 (6 kV contact, 8 kV air)
Electromagnetic fields Conforming to IEC 61000-4-3 Level 3 (10 V/m)
Fast transients Conforming to IEC 61000-4-4 Level 3 (2 kV)
Shock waves Conforming to IEC 61000-4-5 Level 3 (2 kV)
Radiated and conducted emissions
CISPR11 Group 1 class A
CISPR22 Class A
References : page 2/20
Dimensions :page 2/20
Schemes : page 2/21
2/19
2
Characteristics(continued) 2
Zelio Time -industrial timing relays 2
Single or multifunction relays, solid state output,width 22.5 mm
Timing relay type RE9 TA On-delay
RE9 RAOff-delay
RE9 MSMultifunction
Supply characteristicsSupply voltage V �/� 24…240 � 24…240 �/� 24…240.
See page 2/20
Voltage limits Of the control circuit 0.85…1.1 Un
Frequency Hz 50…60 ± 5 %
Control contact Mechanical only In series Between Y2 and A2 In series
Maximum length of connecting cable
From contact to RE9 m – 20 –
Control input consumption Input Y2 mA – 5 –
Timing characteristicsSetting accuracy < ± 20 %
Repeat accuracy < 1 %
Minimum reset time After the time delay period ms 100
Minimum switching time ms – 40 –
Maximum immunity to microbreaks
During the time delay period ms 100 2 70After the time delay period ms 2 – 2
Temperature drift ≤ 0.1 % per degree centigrade
Switching characteristics (solid state type)Maximum continuous current At ambient temperature: 20 °C A 0.7 (minimum 10 mA)
Maximum overload current VDE 0435 part. 303, 4.8.3/Class II
A 15 for 10 ms
Maximum voltage drop Closed state V 3 (at 0.7 A)
Leakage current Open state mA ≤ 6 ≤ 1 ≤ 6
Maximum dissipated power W 2.5 4 2.5
Derating For temperature > 20 °C mA Without
Electrical durability In millions of operating cycles > 100
References : page 2/20
Dimensions :page 2/20
Schemes : page 2/21
2/20
2
Functions,references,dimensions 2
Zelio Time - industrial timing relays 2
Single or multifunction relays, solid state output, width 22.5 mm
Solid state output� Multifunction or single function� Multivoltage� Screw terminals
Function diagramsFunction A Function C Function H
Delay on energisation
Timing after opening of control contact
Timing on energisation
Function D Function DiSymmetrical flashing, start with output in rest position
Symmetrical flashing, start with output in operating position
References
Functions A C A, H, D, DiVoltages ��or � 24…240 V � – ��(A)
��24…240 V – � ��(H, D, Di)Timing ranges 0.1 s…10 s RE9 TA11MW RE9 RA11MW7 RE9 MS21MW
0.3 s …30 s RE9 TA31MW RE9 RA31MW7 –3 s…300 s RE9 TA21MW RE9 RA21MW7 RE9 MS21MW40 s…60 min RE9 TA51MW RE9 RA51MW7 –
Weight (kg) 0.110 0.110 0.110
DimensionsRail mounting Screw fixing
U
RT
U
C
RT
U
RT
T T T T T T
U
R
U
RT T T T T
5608
54
5608
55
5608
55
89,5
82
78
80
66
78
Characteristics :pages 2/18 and 2/19
Schemes :page 2/21
2/21
2
Schemes 2 Zelio Time - industrial timing relays 2
Single or multifunction relays, solid state output, width 22.5 mm
Terminal blocksRE9 TA RE9 RA RE9 MS
Recommended application schemesRE9 TA
The timing relay is placed in series, with the load whose energisation is to be delayed on one side and switch K on the other side. The mains supply may be a.c. or d.c. and the voltage may be between 24 V and 240 V. See function diagram on page opposite.
RE9 RA
The timing relay is placed in series with the load whose de-energisation is to be delayed. Switch K is connected to terminals Y2 and A2 of the timing relay, and terminal A2 is connected to the mains supply, as indicated in the diagram opposite. The device is operated from an a.c. mains supply whose voltage is between 24 V and 240 V. See function diagram on page opposite.
RE9 MSDelay on energisationFunction A
Timing on energisationFunction H Selection of the timing range
X3-X4 not linked: range 3 s…300 s(factory configuration)
X3-X4 linked: range 0.1 s…10 s
Link to be made between terminals X1 and X4
Symmetrical flasher,start with output in rest positionFunction D
Symmetrical flasher,start with output in operating positionFunction Di
Link to be made between terminals X2 and X4 on one side and between X1 and X2 on the other side
Link to be made between terminals X1 and X4
Note : For supply voltages greater than 30 V, the rated voltage of the load is equal to the supply voltage. For a supply voltage of 24 V, the voltage drop within the RE9 relay must be taken into account (about 3 V); a coil with a nominal voltage of 21 V must therefore be selected for the load.
A1 L A1 L
Y2 A2
A1 L
X1 X3X2
X4
LA1KRE9-TA
Supply � or �
Load
LA1
K A2Y2
RE9-RA
Supply �
Load
A2L A1A1KX3 X4
RE9-MS
Supply � or �
Load
A2L A1A1KX1 X3 X4
RE9-MS
Supply �
Load
A2L A1A1KX2 X3X1 X4
RE9-MS
Supply �
Load
A2L A1A1KX2 X3 X4
RE9-MS
Supply �
Load
Characteristics :pages 2/18 and 2/19
Dimensions :page 2/20
2/22
2
Characteristics 2 Zelio Time - modular timing relays 2
Relays with relay output, width 17.5 mm
Timing characteristicsRelay type RE11 R���������������� RE11 RME MU
Selectable timing rangesby selector switch on front panel
s 0.1…1 0.1…11…10 1…10
min 0.1…1 0.1…11…10 1…10
h 0.1…1 0.1…1
1…10 1…1010…100 –
Repeat accuracy(with constant parameters)
Conforming to IEC 61812-1 ± 0.5 %
Drift Temperature ± 0.05 % / °C
Voltage ± 0.2 % / VSetting accuracy at full scale
Conforming to IEC 61812-1 ± 10 % at 25 °C
Minimum duration of control pulse
Typical ms 30Typical with load in parallel ms 100
Maximum reset time by de-energisation
Typical ms 100
Immunity to microbreaks Typical ms > 10
Supply characteristicsRelay type RE11 R���������������� RE11 R���� JU
Supply voltage V �/��12…240��24/� 24…240 depending on version
�/� 12 V
Frequency Hz 50/60
Operating range 85…110 % of Un 90…120 % of UnOn-load factor 100 %Maximum power consumption
Depending on model
�/� 12 V VA/W – 0.4
� 24 V W 0.6 –� 240 V W 1.5 –� 240 V VA 32 –
Output characteristicsRelay type RE11 R���������������� RE11 RME MU
Output type Relay, 1 C/O contact, AgNi (cadmium-free)Breaking capacity ��2000 VA, ��80 W ��1250 VA, ��50 W
Maximum breaking current A ��8, ��8 ��5, ��5
Minimum breaking current mA 10 /� 10 V
Maximum switching voltage V �/��250 (except RE11 RMX MU: � 250 and � 150 )Electrical life 105 operations 8 A 250 V resistive 105 operations 5 A 250 V resistive
Mechanical life 5 x 106 operationsDielectric strength Conforming to IEC 61812-1 kV 2.5/1min/1 mA/50 Hz
Impulse voltage Conforming to IEC 60664-1, IEC 61812-1
kV 5, wave: 1.2/50 µs
Display characteristicsState indication by 1 LED Green Operating status indication
Pulsing: relay energised, no timing in progress (except functions Di-D and Li-L)Flashing: timing in progressOn steady: relay energised, no timing in progress
Input characteristicsInput type Volt-free contact (no potential)
Control possible by 3-wire sensor with PNP output, maximum residual voltage: 0.4 V whatever the supply voltage of the timer
References :pages 2/23 and 2/24
Dimensions :pages 2/24 and 2/26
Schemes :pages 2/25 and 2/27
2/23
2
Characteristics (continued) 2 Zelio Time - modular timing relays 2
Relays with relay output, width 17.5 mm
General characteristicsConforming to standards IEC 61812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC
(� marking) + EMC directive (89/336/EEC + IEC 60669-2-3)
Approvals cULus, CSA,GL except RE11 RMX MU and RE11 RME MU
Ambient air temperature around the device
Storage °C - 30…+ 60
Operation °C - 20…+ 60
Creepage distance and clearance
Conforming to IEC 60664-1 kV 4 kV/3
Degree of protectionconforming to IEC 60529
Terminal block IP 20Housing IP 40
Front panel IP 50
Vibration resistance Conforming to IEC 60068-2-6 f = 10…55 HzA = 0.35 mm
Relative humiditywithout condensation
Conforming to IEC 60068-2-3 93 %
Electromagnetic compatibility Immunity to electrostatic discharge,conforming to IEC 61000-4-2
Level III (Air 8 kV/Contact 6 kV)
Immunity to electromagnetic fields,conforming to ENV 50140/204 (IEC 61000-4-3)
Level III (10 V/m: 80 MHz…1 GHz)
Immunity to fast transients in bursts,conforming to IEC 61000-4-4
Level III (direct 2 kV / capacitive connecting clip 1 kV)
Immunity to surges on the power supplies,conforming to IEC 61000-4-5
Level III (common mode 2 kV / differential mode 1 kV)
Immunity to radio frequency interference in common mode,conforming to ENV 50141 (IEC 61000-4-6)
Level III (10 V rms: 0.15…80 MHz)
Immunity to voltage dips and breaks,conforming to IEC 61000-4-11
30 % / 10 ms60 % / 100 ms95 % / 5 s
Radiated and mains conducted disturbance,conforming to EN 55022(EN 55011 Group 1)
Class B
Fixing Symmetrical mounting rail (EN 50022)
mm 35
Clamping capacity Without cable end mm2 2 x 2.5 and 1 x 4With cable end mm2 2 x 1.5
Spring terminals, 2 terminals per connection point
Flexible cable mm2 1.5
Solid cable mm2 2.5
Housing material Self-extinguishing
References :pages 2/23 and 2/24
Dimensions :pages 2/24 and 2/26
Schemes :pages 2/25 and 2/27
2/24
2
Functions,references,dimensions,schemes 2
Zelio Time - modular timing relays 2
Relays with relay output,width 17.5 mm
Output 1 C/O contact� Dual function or single function� Multi-range (7 selectable ranges)� Multivoltage� 1 relay output: 8 A� Screw terminals� State indication by 1 LED� Option of supplying a load in parallel� 3-wire sensor control option
Function diagramsFunction A Function AtDelay on energisation
Delay on energisation with memory
T = t1 + t2 + …
Function H Function HtTiming on energisation
Timing on energisation with memory
T = t1 + t2 + …
References
Functions Dual function Dual functionA - At H - Ht
Timing ranges 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
Voltages �/ � 12 V – –��24 V / � 24…240 V RE11 RA MU RE11 RH MU
Nominal output current 8 A 8 A
Connection Screw terminals � �
Weight (kg) 0.060 0.060
Dimensions and connection schemesDimensions
U
RT
U
R
C
t1 t2
U
RT
U
R
C
t1 t2T
5219
29
5219
29
5,5
72
17,9
81
Characteristics :pages 2/22 and 2/23
Schemes :page 2/27
2/25
2
22
Function L Function LiAsymmetrical flashing, start with output in rest position
Asymmetrical flashing, start with output in operating position
Function B Function CTiming on impulse, one shot
Timing after opening of control contact
Dual function Dual function Single function Single functionL - Li L - Li B C1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
– RE11 RL JU – –RE11 RL MU – RE11 RB MU RE11 RC MU8 A 8 A 8 A 8 A� � � �
0.060 0.060 0.060 0.060
Connection schemesFunctions A and At
Functions H and Ht
Functions L and Li
Functions B and C
(1) Link A1-Y1 for function L only.
Tr Ta
U
RTa Tr
U
R
U
R
C
T T
U
C
RT
5219
30
5219
30
521
929
521
929
A2 Y1
A1
U
+
–
16
15R
18
A2 Y1
A1
U
+
–
16
15R
18
A2 Y1
A1
U
+
–
16
15R
18
(1)
A2 Y1
A1
U
+
–
16
15R
18
Characteristics :pages 2/22 and 2/23
Dimensions :page 2/26
2/26
2
Functions,references,dimensions,scheme 2
Zelio Time - modular timing relays 2
Relays with relay output, width 17.5 mm
Output 1 C/O contact� Multifunction� Multi-range (6 or 7 selectable ranges)� Multivoltage� 1 relay output: 5 or 8 A� Screw or spring terminals� State indication by 1 LED� Option of supplying a load in parallel� 3-wire sensor control option
Function diagramsFunction A Function At Function B
Delay on energisation
Delay on energisation with memory
T = t1 + t2 + …
Timing on impulse, one shot
Function C Function H Function HtTiming after opening of control contact
Timing on energisation
Timing on energisation with memory
T = t1 + t2 + …
Function D Function Di Function AcSymmetrical flashing, start with output in rest position
Symmetrical flashing, start with output in operating position
Timing after closing and opening of control contact
References
Functions Multifunction MultifunctionA - At - B - C - H - Ht - D - Di - Ac - Bw A - At - B - C - H - Ht - D - Di - Ac - Bw
Timing ranges 6 or 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 hVoltages �/��12 V – –
��24 V / ��24…240 V RE11 RM MU –�/��12…240 V – RE11 RM MW
Nominal output current 8 A 8 A
Connection Screw terminals � �
Spring terminals – –Weight (kg) 0.060 0.060
Dimensions and connection schemeDimensions
RE11 RM���� MU, RE11 RM MW, RE11 RM JU RE11 RM MWS
U
RT
U
R
C
t1 t2
U
R
C
T T
U
C
RT
U
RT
U
R
C
t1 t2T
T T T T T T
U
RT T T T T
U
R
U
C
RT T
5219
31
5219
31
5,5
72
17,9
81
5,5
72
17,9
81
Characteristics :pages 2/22 and 2/23
Schemes :page 2/25
2/27
2
22
Function Bw Function Ad Function Ah Function N Function OPulse output (width adjustable)
Timing on closing of control contact
Flashing single cycle by operation of control contact
"Safe-guard"
"Delayed safe-guard"
Function P Function Pt Function T Function Tt Function WDelayed fixed-length pulse
P = 500 ms
Impulse counter (on-delay)
T = t1 + t2 + …P = 500 ms
Bistable relay
Timed impulse relay
On-delay after opening of control contact
Multifunction Multifunction Multifunction MultifunctionA - At - B - C - H - Ht - D - Di - Ac - Bw A - At - B - C - H - Ht - D - Di - Ac - Bw A - At - B - C - H - Ht - D - Di Ad - Ah - N - O - P - Pt - T - Tt - W1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
– RE11 RM JU – –
– – RE11 RME MU RE11 RMX MURE11 RM MWS – – –8 A 8 A 5 A 8 A
– � � �
� – – –
0.060 0.060 0.060 0.060
Connection scheme
(1) Contact Y1 :- Control for functions B, C, Ac, Bw, Ad, Ah, N, O, W, T, Tt.- Partial stop for functions At, Ht and Pt.- Function D if Di selected.- Not used for functions A, H and P.
U
R
C
T T
U
R
C
T T
U
R
C
TT T T T
U
C
R T T T
U
C
Rt<T
U
RT P
t1 t2 P
U
G
R
U
C
R
U
C
RT t<T T
U
C
R
5219
32
5219
31
5219
31
5219
33
A2 Y1
A1
U
+
–
16
15R
18
Y1(1)
Characteristics :pages 2/22 and 2/23
Dimensions :page 2/24
2/28
2
Characteristics 2 Zelio Time -industrial timing relays 2
Single, dual or multifunction relays, relay output,width 22.5 mm
Timing characteristicsRepeat accuracy(with constant parameters)
Conforming to IEC 61812-1 ± 0.5 %
Drift Temperature ± 0.05 % / °CVoltage ± 0.2 % / V
Full scale setting accuracy Conforming to IEC 61812-1 ± 10 % at 25 °C
Minimum duration of control impulse
Typical ms 30Typical under load ms 100
Maximum reset time by de-energisation
Typical ms 100
Immunity timeto microbreaks
Typical ms > 10
Supply characteristicsMultivoltage supply Depending on version, see pages 2/30 to 2/33
Frequency Hz 50/60Operating range 85…110 % Un (85…120 Un for �/��12 V )On-load factor 100 %
Maximum power consumption
Depending on model
� 24 V W 0.6
� 240 V W 1.5� 240 V VA 32
Output characteristicsOutput type C/O contact, AgNi (cadmium-free)
Breaking capacity ��2000 VA, ��80 WMaximum breaking current A �/�� 8Minimum breaking current mA 10 / ��5 V
Maximum switching voltage V �/��250 Electrical durability 105 operations 8 A 250 V resistive Mechanical durability 5 x 106 operations
Dielectric strength Conforming to IEC 61812-1 kV 2.5/1 min/1 mA/50 HzImpulse voltage Conforming to IEC 60064-1,
IEC 61812-1kV 5, wave 1.2/50 µs
Display characteristicsState indication by 2 LEDs Green Operating status indication green LED
Pulsing: relay energised, no timing in progress (except Di-D and Li-L)
Flashing: timing in progress
On steady: relay energised, no timing in progress
Yellow On-delay relay
Input characteristicsInput type Volt-free contact (no potential)
Control possible by 3-wire sensor with PNP output, maximum residual voltage: 0.4 V whatever the supply voltage of the timer
References :pages 2/30 to 2/33
Dimensions :pages 2/30 to 2/33
Schemes :pages 2/30 to 2/33
2/29
2
Characteristics (continued) 2 Zelio Time -industrial timing relays 2
Single, dual or multifunction relays, relay output, width 22.5 mm
General characteristicsConforming to standards IEC 1812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC
(� marking) + EMC (89/336/EEC + IEC 669-2-3)
Product certifications c UL us, CSA,GL except RE 88 865 503 and RE 88 865 265
Temperature limits Operation °C - 20…+ 60 Storage °C - 30…+ 60
Creepage distance and clearance
Conforming to IEC 60664-1 kV 4 kV/3
Degree of protectionconforming to IEC 529
Terminal block IP 20
Housing IP 40Front face IP 50 except RE 88 865 265 (IP 30)
Vibration resistance Conforming to IEC 68-2-6 f = 10…55 HzA = 0.35 mm
Relative humiditywithout condensation
Conforming to IEC 68-2-3 93 %
Electromagnetic compatibility
Immunity to electrostatic discharge,conforming to IEC 1000-42
Level III (Air 8 kV/Contact 6 kV)
Immunity to electromagnetic fields, conforming to ENV 50140/204 (IEC 1000-4-3)
Level III (10 V/m: 80 MHz…1 GHz)
Immunity to fast transients in bursts,conforming to IEC 1000-4-4
Level III (direct 2 kV / capacitive connecting clip 1 kV)
Immunity to surges on the power supply, conforming to IEC 1000-4-5
Level III (common mode 2 kV / differential mode 1 kV)
Immunity to radio frequency interference in common mode conforming to ENV 50141 (IEC 1000-4-6)
Level III (10 V rms: 0.15…80 MHz)
Immunity to voltage dips and breaks, conforming to IEC 1000-4-11
30 % / 10 ms
60 % / 100 ms95 % / 5 s
Radiated and mains conducted disturbance,conforming to EN 55022 (EN 55011 Group 1)
Class B
Fixing Symmetrical mounting rail (EN 50022)
mm 35
Clamping capacity Without cable end mm2 2 x 2.5
With cable end mm2 2 x 1.5
Spring terminals, 2 terminals per connection point
Flexible cable mm2 1.5Solid cable mm2 2.5
Housing material Self-extinguishing
References :pages 2/30 to 2/33
Dimensions :pages 2/30 to 2/33
Schemes :pages 2/30 to 2/33
2/30
2
Functions, references,dimensions,schemes 2
Zelio Time -industrial timing relays 2
Single, dual or multifunction relays, relay output, width 22.5 mm
Relay outputs, 1 C/O and 2 C/O contacts� Single or dual function� Multi-timing range (7 switchable ranges)� Multivoltage� 1 and 2 relay outputs: 8 A - 250 V (10 A UL)� Screw or spring terminals� State indication by 1 LED� Option of supplying a load in parallel� 3-wire sensor control option
Function diagramsFunction B Function C Function Q
Timing on impulse, one shot
Off-delay
Star-delta starting
Function KDelay on de-energisationTrue Off-delay(without auxiliary supply)2 timed contacts
References
Connection Screw terminals � � � �
Spring terminals – – – –Functions Single function Single function Single function Single function
B C Q K
Timing ranges 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
4 ranges – – – 0.6 s - 2.5 s - 20 s - 160 s
Selectable interswitching time – – 20 - 40 - 60 - 80 -100 - 120 - 140 ms
–
Relay output 1 timed contact 1 timed contact 1 timed contact 2 timed contactsVoltages ��24 V / ��24…240 V RE 88 865 125 RE 88 865 135 RE 88 865 175 RE 88 865 265
�/��12 V – – – –
�/��12…240 V – – – –��230 / 380 V – – RE 88 865 176 –
Weight (kg) 0.090 0.090 0.090 0.090
Dimensions and connection schemesDimensions Connection schemes
All functions except K RE 88 865 3�������� and RE 88 865 215
U
C
R∞ T
U
C
R∞ T
TR
U
Ti
TR1/R2
U
5611
72
5611
72
5611
72
5611
76
32
3,5
95
5
57 78
63 22,5
A1 15 Y1
18 16 A2
U
A1R1 R215
A21816
25/21
28/2426/22
Y1
+
Characteristics :pages 2/28 and 2/29
2/31
2
22
Function A Function H Function LDelay on energisation
Timing on energisation
Asymmetrical recyclerStart after pause
Function At Function Ht Function LiTiming on energisation with memory
Delay on energisation with memory
Asymmetrical recyclerPulse start
� � � �
– – – –Dual function Dual function Dual function Dual function
A - At A - At H - Ht Li - L
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
– – – –
– – – –
1 timed contact 2 timed contacts 1 timed contact 1 timed contactRE 88 865 115 RE 88 865 215 RE 88 865 145 RE 88 865 155– – – –
– – –– – – –0.090 0.090 0.090 0.090
Function KRE 88 865 265
All functions except L and LiRE 88 865 1������������
Functions L and LiRE 88 865 155
Function QRE 88 865 17����
(1) Link A1-Y1 for function L only.
U
RT T
R
U
T1R
T2
U
U
C
Rt1 t2
T = t1+t2t1
R
C
U
t2T = t1+t2
T1R
U
T2
5611
72
5611
76
5611
72
5611
73
U
A1
A2
R1 R2
15
1816
25
2826
+U
A1R
15
A21816
Y1
+U
A1R
15
(1)
A21516
Y1
+
U
A1R
15
A21828
+
Characteristics :pages 2/28 and 2/29
2/32
2
Functions,references,scheme 2
Zelio Time -industrial timing relays 2
Single, dual or multifunction relays, relay output, width 22.5 mm
Relay outputs, 1 C/O and 2 C/O contacts� Multifunction� Multi-timing range (7 switchable ranges)� Multivoltage� 1 and 2 relay outputs: 8 A - 250 V (10 A UL) of which 1 convertible to instantaneous � Screw or spring terminals� State indication by 1 LED� Option of supplying a load in parallel� 3-wire sensor control option
Function diagramsFunction A Function At Function B
Delay on energisation
Timing on energisation with memory
Timing on impulse, one shot
Function C Function H Function HtOff-delay
Timing on energisation
Delay on energisation with memory
Function Di Function D Function AcFlashing relayPulse start
Flashing relayStart after pause
Timing after closing/opening of control contact
Function BwPulse output (adjustable)
References
Connection Screw terminals � � –Spring terminals – – �
Functions Multifunction Multifunction MultifunctionA - At - B - C - H - Ht - Di - D - Ac - Bw
A - At - B - C - H - Ht - Di - D - Ac - Bw
A - At - B - C - H - Ht - Di - D - Ac - Bw
Timing ranges 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 hRelay output 1 timed contact 2 timed contacts, 1 of which
convertible to instantaneous1 timed contact
Voltages ��24 V / ��24…240 V RE 88 865 105 RE 88 865 305 –�/��12 V RE 88 865 100 RE 88 865 300 –
�/��12…240 V RE 88 865 103 RE 88 865 303 RE 88 865 503Weight (kg) 0.090 0.090 0.090
U
C
R∞ T
U
C
Rt1 t2
T = t1+t2
U
C
R∞ T
TR
U
Ti TR
U
t1R
C
U
t2T = t1+t2
U
RT T T
R1/R2
UU
C
RT T
U
C
RT T
5611
71
5611
75
5611
74
Characteristics :pages 2/28 and 2/29
2/33
2
22
Function Ad Function Ah Function N Function O Function PDelay on energisation by switch
Flashing single cycle by switch
"Safe-guard"
"Delayed safe-guard"
Delayed fixed-length pulse
Function Pt Function TI Function Tt Function WImpulse counter (on-delay)
Impulse relay
Timed impulse relay
Timing after pulse on control contact
Connection scheme
� �
– –Multifunction Multifunction
Ad - Ah - N - O - P - Pt - Tl - Tt - W Ad - Ah - N - O - P - Pt - Tl - Tt - W
1 timed contact 2 timed contacts
RE 88 865 185 RE 88 865 385– –
– –0.090 0.090
U
C
RTT
U
C
RTTTT
U
C
RTT
U
C
RTT T
U
RT P
P = 500 ms
U
C
RP
T = t1 + t2P = 500 ms
t2t1
U
C
R
U
C
RT t
U
C
RT T
A2 Y1
A1
U
+
–
16
15R
18
5611
71
5611
71
Characteristics :pages 2/28 and 2/29
2/34
2
Characteristics 2 Zelio Time - industrial timing relays 2
Single or multifunction relays, relay output, width 22.5 mm
The RE7 range of relays, with only 23 references, covers all timing applications.
These relays offer multi-range timing from 50 ms to 300 h.
They are multivoltage.
Three models combine several different functions: multifunction relays.
These products have a transparent, hinged flap on their front face to avoid any accidental alteration of the settings. This flap can be directly sealed.
Presentation
5608
72
References :pages 2/36 to 2/39
EnvironmentConforming to standards IEC 61812-1, EN 61812-1Product certifications CSA, GL pending, UL���� marking Zelio Time timing relays conform to European regulations relating to � marking
Ambient air temperaturearound the device
Storage °C - 40…+ 85Operation °C - 20…+ 60
Permissible relative humidity range
Conforming to IEC 60721-3-3 15…85 % Environmental class 3K3
Vibration resistance Conforming to IEC 60068-2-6, 10 to 55 Hz
a = 0.35 ms
Shock resistance Conforming to IEC 60068-2-27 15 gn - 11 ms
Degree of protection Casing IP 50Terminals IP 20
Degree of pollution Conforming to IEC 60664-1 3
Overvoltage category Conforming to IEC 60664-1 IIIRated insulation voltageBetween contact circuit and power supply or between contact circuit and control inputs
Conforming to IEC V 250Conforming to CSA V 300
Test voltage for insulation tests
Dielectric test kV 2.5
Shock wave kV 4.8Voltage limits Power supply circuit 0.85…1.1 UcFrequency limits Power supply circuit Hz 50/60 ± 5 %
Disconnection value Power supply circuit > 0.1 UcMounting positionwithout derating
In relation to normal vertical mounting plane
Any position
CablingMaximum c.s.a.
Flexible cable without cable end mm2 2 x 2.5 Flexible cable with cable end mm2 2 x 1.5
Tightening torque N.m 0.6…1.1
Immunity to electromagnetic interference (EMC) (application class 2 conforming to EN 61812-1)Electrostatic discharge Conforming to IEC 61000-4-2 Level 3 (6 kV contact, 8 kV air)
Electromagnetic fields Conforming to IEC 61000-4-3 Level 3 (10 V/m)Fast transients Conforming to IEC 61000-4-4 Level 3 (2 kV)Shock waves Conforming to IEC 61000-4-5 Level 3 (2 kV)
Radiated and conducted emissions
CISPR11 Group 1 class ACISPR22 Class A
Consumption� 50/60 Hz �
Average consumption 24 V 48 V 110 V 240 V 24 V 48 V 110 V 240 VRE7-��11BU VA 0.7 1.6 1.8 8.5 W 0.5 1.2 – –
RE7-��12BU and RE7-��13BU VA 1.2 2 2.8 12.5 W 0.8 1.6 – –RE7-����MW (1) VA 2 2.5 3.2 6 W 2 1 3.2 2(1) RE7-RB��MW: current peak on energisation = 1 A / 30 ms.
2/35
2
Characteristics (continued) 2 Zelio Time - industrial timing relays 2
Single or multifunction relays, relay output, width 22.5 mm
Timing characteristicsSetting accuracy As % of the full-scale value ± 10 %Repeat accuracy ± 0.2 %Influence of voltage In the voltage range, 0.85…1.1 Un < 0.2 %
Influence of temperature < 0.07 %/°CImmunity to microbreaks ms 3Minimum control pulse ms 20 (except RE7-RB1�MW: 1 s)
Reset time ms 50
Output circuit characteristicsMaximum switching voltage V � 250
Mechanical durability In millions of operating cycles 20Current limit Ith A 8 (except RE7-RB��MW: 5 A)Rated operational limits at 70 °CConforming to IEC 60947-5-1/1991and VDE 0660
24 V 115 V 250 V
AC-15 A 3 3 3DC-13 A 2 0.2 0.1
Minimum switching capacity 12 V/10 mA
Contact material 90/10 nickel silver(except RE7-RB��MU: gold flashed silver alloy)
Remote control input characteristicsMaximum voltage Applicable to inputs
Y1Z2, X1Z2, X2Z2V 60
Signal delivered by control inputs Y1Z2, X1Z2, X2Z2
No galvanic insulation between these inputs and the supply
Switching current mA < 1Maximum distance m 50
Compatibility 3/4-wire PNP and NPN Telemecanique sensors or other sensors without an internal load
Potentiometer for connection between terminals Z1Z2, Z3Z2
Type Linear at ± 20 %Resistance kΩ 47 ± 20 %
Power W 0.2Maximum distance m 25 by shielded cable: shielding linked to terminal Z2
References :pages 2/36 to 2/39
a.c. load d.c. loadCurve 1 Curve 2 Load limit curveElectrical durability of contacts on resistive load in millions of operating cycles
Reduction factor k for inductive loads (applies to values taken from durability curve 1)
A RE7-RB��������MW A RE7-RB��������MW1 L/R = 20 ms2 L/R with load protection diode3 Resistive load
Example:An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.1 A and cos ϕ = 0.3.For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles.As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2.
For cos ϕ = 0.3: k = 0.6The electrical durability therefore becomes:1.5 106 operating cycles x 0.6 = 900 000 operating cycles.
10
1
0,1
0,010 1 2 3 4 5 6 7 8
A
Current broken in A
M
illio
ns o
f ope
ratin
g cy
cles
Power factor on breaking (cos ϕ)
1
0,6
0,5
0,9
0,8
0,7
0,4
0,31 0,8 0,6 0,5 0,4 0,3 0,2
R
educ
tion
fact
or k 300
40
30
200
100
50
20
100,1 0,2 0,5 1 2 5 2010
1
2
3
A
Current in A
Vol
tage
in V
RE7
K
+
–
2/36
2
Functions,references,dimensions,schemes 2
Zelio Time - industrial timing relays 2
Single or multifunction relays, relay output, width 22.5 mm
Output 1 C/O contactMultiple timing ranges
Function diagramsFunction A Function At Function Aw
Delay on energisation
Delay on energisation with memory
Off-delay on energisation or on opening of control contact
T = t1 + t2 + …
Function Ac Function AkTiming after closing and opening of control contact
Asymmetrical On-delay and Off-delay with external control
T = t1 + t2 + …T = t’1 + t’2 + …
Ta = t1 + t2 + …Tr = t’1 + t’2 + …
References
Functions A A, Aw, At Ac Ak
Timing ranges 0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
Voltages ��or � 24 V � � � �
��110…240 V � � � �
� or � 42…48 V – � � �
��or � 24…240 V – – – –References RE7 TL11BU RE7 TM11BU RE7 MA11BU RE7 MV11BU
Weight (kg) 0.150 0.150 0.150 0.150
Dimensions and connection schemesDimensions
Rail mounting Screw fixing
U
RT
U
R
C
t1 t2
U
R
C
T T
U
C
t1
G
Rt'1t2 t'2
U
C
t1
G
Rt'1t2 t'2
5608
73
5608
73
5608
74
5608
74
89,5
80
82
22,5
78
66
78
Ø4
Characteristics :pages 2/34 and 2/35
Schemes :pages 2/40 and 2/41
2/37
2
22
Function K Function C Function H Function Ht Function WDelay on de-energisation (without auxiliary supply)
Timing after openingof control contact
Timing on energisation
Timing on energisation with memory
On-delay after opening of control contact
T + t1 + t2 + …
Function D Function Di Function L Function Li Function LtSymmetrical flashing, start with output in rest position
Symmetrical flashing, start with output in operating position
Asymmetrical flashing, start with output in rest position
Asymmetrical flashing, start with output in operating position
Asymmetrical flashing with partial stop of timing
Tr = t1 + t2 + …Ta = t’1 + t’2 + …
(1) If the device has been stored, de-energised, for more than a month, it must be energised for about 15 seconds in order to activate it. Subsequently, it only takes 1 second to start the time delay. � If this time is not complied with, the relay remains energised indefinitely.
(2) 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).
K C H Ht, W D L, Li, Lt A, C, H, W, D, Di
0.05 s…10 min 7 ranges
0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
– � � � � � �
– � � � � � �
– � – � – � �
� – – – – – –RE7 RB11MW RE7 RA11BU
RE7 RM11BU low level contact
RE7 PE11BU RE7 PM11BU RE7 CL11BU RE7 CV11BU RE7 ML11BU
0.150 0.150 0.150 0.150 0.150 0.150 0.150
Connection schemesRE7 TL11BU
RE7 RB11MW
RE7 PE11BU
RE7 TM11BU,RE7 RA11BURE7 RM11BU,RE7 PM11BU
RE7 MA11BURE7 MV11BU
RE7 CL11BU
RE7 CV11BU
U
RT
> 1 s (1)
U
C
RT
U
RT
U
R
C
t1 t2T T
U
C
R
T T T T T T
U
R
U
R1/R2
T T T T T
R2 inst.(2)
Tr Ta
U
RTa Tr
U
R
R
G
t1 t’2t2 t’1
U
5608
75
5608
75
5608
76
5608
76
5608
77
5608
77
5609
08
A1 15 B1
18 16 A2
1815B
1
A1
A2
16
A1 15
18 16 A2
1815A
1A
2
16
A1 15 B1
18 16 A2
1815B
1
A1
A2
16
A1 15 B1Z1 B2
Y1X1 Z218 16 A2
1815B
1
A1
B2
A2
16
A1 15 B1Z1 B2
Y1X1 Z218 16 A2
1815B
1
A1
B2
A2
16
A1 15 B1
18 16 A2
1815B
1
A1
A2
16
A1 15 B1Z3Z1 B2
X2X1 Z218 16 A2
1815B
1
A1
B2
A2
16
Characteristics :pages 2/34 and 2/35
Dimensions :page 2/36
Schemes :pages 2/40 and 2/41
2/38
2
Functions,references,dimensions,schemes 2
Zelio Time - industrial timing relays 2
Single or multifunction relays, relay output, width 22.5 mm
Output 2 C/O contactsMultiple timing ranges
Function diagramsFunction A Function Ac Function C
Delay on energisation
Timing after closing and opening of control contact
Timing after opening of control contact
Function KDelay on de-energisation (without auxiliary supply)
(1) 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).(2) If the device has been stored, de-energised, for more than a month, it must be energised for
about 15 seconds in order to activate it. Subsequently, it only takes 1 second to start the time delay. � If this time is not complied with, the relay remains energised indefinitely.
References
Functions A Ac C KTiming ranges 0.05 s…300 h
10 ranges0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
0.05 s…10 min 7 ranges
Voltages ��or � 24 V � � � –
��110…240 V � � � –� or � 42…48 V � � � –��or � 24…240 V – – – �
References RE7 TP13BU RE7 MA13BUsymmetrical
RE7 RL13BUlow level contact
RE7 RB13MW
Weight (kg) 0.150 0.150 0.150 0.150
Dimensions and connection schemesDimensions
Rail mounting Screw fixing
U
R1/R2
T
R2 inst.(1)
U
C
R1/R2
T T
R2inst.(1)
U
R1/R2
C
T
R2 inst.(1)
U
R1
R2T
> 1 s (2)
5609
02
5609
03
5609
04
5609
04
89,5
80
82
22,5
78
66
78
Ø4
Characteristics :pages 2/34 and 2/35
Schemes :pages 2/40 and 2/41
2/39
2
22
Function D Function Di Function HSymmetrical flashing, start with output in rest position
Symmetrical flashing, start with output in operating position
Timing on energisation
Function Qg Function Qt Function WStar-delta timing Star-delta timing On-delay after
opening of control contact
(1) 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).
H W D Qt Qg A, C, H, W, D, Di, Qg, Qt0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
0.05 s…300 h 10 ranges
� � � � � � –� � � � � � –� � � � � � –
– – – – – – �
RE7 PP13BU RE7 PD13BU RE7 CP13BU RE7 YA12BU RE7 YR12BU RE7 MY13BU RE7 MY13MW
0.150 0.150 0.150 0.150 0.150 0.150 0.150
Connection schemesRE7 TP13BU
RE7 RB13MW
RE7 YA
RE7 RL13BU, RE7 MA13BURE7 PD13BU
RE7 PP13BURE7 CP13BU
RE7 YR RE7 MY13BU RE7 MY13MW
U
R1/R2
T T T T T T
R2 inst. (1)
U
R1/R2
T T T T T
R2 inst. (1)
U
R1/R2
T
R2 inst. (1)
T T50 ms
U
R1
R2
U
R1
R2T T
50 ms
U
C
R1/R2
T
R2 inst. (1)
5609
05
5609
05
5609
06
5609
07
5609
07
5609
08
5609
08
A1 15 B125 (21)Z1 B2
28 (24) Z218
26 (22)16 A2
1815B
1
A1
B2
A2
16 2825 (2
1)
26
(24)
(22)
A1 1525Z1
26 Z22818 16 A2
1815A
1A
2
16 2825
26
A1 15 B125 B2
28 26 Z218 16 A2
1815B
1
A1
B2
A2
16 2825
26
A1 15 B125 (21)Y1 B2
26 (22)28 (24) Z218 16 A2
1815B
1
A1
B2
A2
16 2825
26 (24)
(21)
(22)
A1 15 B125 (21)Z1 B2
26 (22)28 (24) Z218 16 A2
1815B
1
A1
B2
A2
16 2825
26 (24)
(21)
(22)
B11717
A1B2
28 26 Z218 16 A2
18
B1
A1
B2
A2
16 28
1726
A1 15 B125 (21)Z1 Y1
26 (22)28 (24) Z218 16 A2
1815B
1
A1
A2
16 28 (24)
25 (21)
26 (22)
A1 15 Y125 (21)Z1 X1
26 (22)28 (24) Z218 16 A2
1815A
1A
2
16 2825
26 (24)
(21)
(22)
Characteristics :pages 2/34 and 2/35
Dimensions :page 2/38
Schemes :pages 2/40 and 2/41
2/40
2
Schemes 2 Zelio Time - industrial timing relays 2
Single or multifunction relays, relay output, width 22.5 mm
Recommended application schemesRE7 TL, TM, TP, CL, CP, ML, MY
Start on energisation
RE7 TM, MA, MV, RM, RL, PM, PD, ML, MYStart by external control
RE7 TM, PM, ML, MY
External control of partial stop
RE7 MA, MV, RA, RM
Start by external control
RE7 RBStart on de-energisation
RE7 RAStart by external control
RE7 PPStart on energisation
RE7 PEStart on energisation
RE7 CVSelection of starting phase
RE7 TM, TP, MA, RA, RM, PP, PM, ML, MYConnection of potentiometer
RE7 MV
Connection of potentiometers to asymmetrical timing relays
RE7 CV
Connection of potentiometers
Connection precautions
No galvanic isolation between supply terminals A1, A2, B1, B2 and control inputs X1, Y1, Z1, Z2.
(1)� 110…240 V except RE7 MY13MW :���24…240 V(2)�� 12…48 V (3)�� 24 V(4) Adjustment of the On-delay period(5) Adjustment of the Off-delay period(6) Start during the On-delay period : X2, Z2 linked. Start during the Off-delay period : X2, Z2 not linked(7) Off-delay adjustment (tr) (contact 15/16 closed)(8) On-delay adjustment (ta) (contact 15/18 closed)
B1 A1B2
A2(1)
(2)
(3) B1 A1B2
A2
Y1
Z2(1)
(2)
(3)
B1 A1B2
A2
X1
Z2(1)
(2)
(3) B1 A1B2
A2
X1
Z2(1)
(2)
(3)
A1
A2A1
A2
Y1 B2
A2
Y1
+
–
B1
A2
Y1
+
–
B1 A1B2
A2
(1)
(2)
(3) B1 B3B2
A2
(1)
(3) B1 A1B2
A2
X2
Z2(6)(1
)(2
)
(3)
Z1Z2
A2Z1Z3 (4) (5)
Z2A2
Z1Z3 (7) (8)
Z2A2A2 Z2
Sup
ply
X1 or Y1 or Z1
Characteristics :pages 2/34 and 2/35
References :pages 2/36 to 2/39
2/41
2
Schemes (continued) 2 Zelio Time - industrial timing relays 2
Single or multifunction relays, relay output, width 22.5 mm
Recommended application schemes (continued)
Power schemeRE7 YA12BU
Control schemesStar-delta function with double On-delay timing Qt
Power schemeRE7 YR12BU
Control schemesStar-delta function with contact for switching to star connection Q
No galvanic isolation between supply terminals A1, A2, B1, B2 and supply terminal Z2.This terminal must therefore never be used (factory setting).Control of several relays with a single external control contact Connection of a Telemecanique 3-wire NPN or PNP sensor
It is advisable to follow the recommended wiring schemes detailed above and on previous pages. However, the connections below are possible if the restrictions given are taken into account.Connection of an external control contact without using terminal Z2: Connection of a Telemecanique 3-wire NPN or PNP sensor without using
terminal Z2:- possible on all RE7 relays with external control option except RE7 RA11BU,- d.c. supply only.
- only possible on relay RE7����BU,- d.c. supply only.
V2
W2
U2
W1
V1
U1
F2
K2
12
34
56
K1
12
34
56
M1
K3
12
34
56
L1 L2 L3
12
34
56
3K1
A1
A2
96
F2
1516
K1T
2122
K3
2122
1314
S1
S2
K1T
A1
A2
1314 K1
K2
A1
A2
K3
A1
A2
2528
K1T
2122
K1
1413
K2
A1 15 B125 B2
28 26 Z218 16 A2
1815B
1
A1
B2
A2
16 2825
26
Y N Δ95
F3 Terminal block
K1T = relay RE7 YA
V2
W2
U2
W1
V1
U1
F2
K2
12
34
56
K1
12
34
56
M1
K3
12
34
56
L1 L2 L3
12
34
56
3 K1
A1
A2
9596
F2
2122
K3
F3
2122
1314
S1
S2
K1T
A1
A2
K3
A1
A2
K2
A1
A2
1413
5354
K2
2817
2122
K1
1817
K1T K2
1413
K1
B11717
A1B2
28 26 Z218 16 A2
18
B1
A1
B2
A2
16 28
1726
Y NΔ
Terminal block
K1T = relay RE7 YR
Z2A2Z2A2 Z2A2
Sup
ply
A1,B1 or B12Y1 or X1
A1,B1 or B12Y1 or X1
A1,B1 or B12Y1 or X1
BNBK NPN
PNPBU
+
Z2A2
Sup
ply
A1,B1 or B12Y1 or X1
+
Z2A2
A1,B1 or B12Y1 or X1
+
Z2A2
A1,B1 or B12Y1 or X1
BNBK NPNBU
Y1
+
B1B2
Z2A2
24or48 V
BNBK PNPBU
Y1
+
B1B2
Z2A2
24or48 V
Characteristics :pages 2/34 and 2/35
References :pages 2/36 to 2/39
2/42
2
Characteristics 2 Zelio Time - industrial timing relays 2
Optimum single-function relays, relay output, width 22.5 mm
The RE8 range of relays is designed for simple and repetitive applications, providing basic functions.
Each relay comprises:- a single timing range,- a C/O output relay.
These products have a transparent, hinged flap on their front face to avoid any accidental alteration of the settings. This flap can be directly sealed.
Presentation
5609
53
EnvironmentConforming to standards IEC 61812-1. EN 61812-1
Product certifications CSA, GL pending. UL��������marking Zelio Time timing relays conform to European regulations relating to � markingAmbient air temperaturearound the device
Storage °C - 40…+ 85
Operation °C - 20…+ 60Permissible relative humidity range
Conforming to IEC 60721-3-3 15…85 % Environmental class 3K3
Vibration resistance Conforming to IEC 60068-2-6, 10 to 55 Hz
a = 0.35 ms
Shock resistance Conforming to IEC 60068-2-27 15 gn - 11 msDegree of protection Casing IP 50
Terminals IP 20Degree of pollution Conforming to IEC 60664-1 3Overvoltage category Conforming to IEC 60664-1 III
Rated insulation voltage Conforming to IEC V 250Conforming to CSA V 300
Test voltage for insulation tests
Dielectric test kV 2.5
Shock wave kV 4.8Voltage limits Power supply circuit 0.9…1.1 UcFrequency limits Power supply circuit Hz 50/60 ± 5 %
Disconnection value Power supply circuit > 0.1 UcMounting positionwithout derating
In relation to normal vertical mounting plane
Any position
Connectionmaximum c.s.a.
Flexible cable without cable end mm2 2 x 2.5Flexible cable with cable end mm2 2 x 1.5
Tightening torque N.m 0.6…1.1
Immunity to electromagnetic interference (EMC) (application class 2 conforming to EN 61812-1)Electrostatic discharge Conforming to IEC 61000-4-2 Level 3 (6 kV contact, 8 kV air)
Electromagnetic fields Conforming to IEC 61000-4-3 Level 3 (10 V/m)Fast transients Conforming to IEC 61000-4-4 Level 3 (2 kV)Shock waves Conforming to IEC 61000-4-5 Level 3 (2 kV)
Radiated and conducted emissions
CISPR11 Group 1 class ACISPR22 Class A
ConsumptionConsumption � �
24 V 110 V 240 V 380 V 415 V 24 VRE8-TA, RA, CL, PE, PU, PT VA 0.7 1.8 8.5 – – W 0.5
RE8-YG, RB VA 0.9 2.5 13 – – W 0.5RE8-YA VA 0.9 2.5 13 8 9 W 0.7
References :pages 2/44 to 2/47
Dimensions :pages 2/44 and 2/46
Schemes :page 2/45
2/43
2
Characteristics (continued) 2 Zelio Time - industrial timing relays 2
Optimum single-function relays, relay output, width 22.5 mm
Timing characteristicsSetting accuracy As % of the full-scale value ± 20 %Repeat accuracy < 1 %Influence of voltage In the voltage range, 0.9…1.1 Un < 2.5 %
Influence of temperature < 0.2 %/°CImmunity to microbreaks ms 3Minimum control pulse ms 26 (except RE8-YG: 60)
Reset time ms 50
Output circuit characteristicsMaximum switching voltage V � 250
Mechanical durability In millions of operating cycles 20Current limit Ith A 8Rated operational limits at 70 °CConforming to IEC 60947-5-1/1991and VDE 0660
24 V 115 V 250 V
AC-15 A 3 3 3DC-13 A 2 0.2 0.1
Minimum switching capacity 12 V/10 mA
Contact material 90/10 nickel silver
Remote control input characteristicsSignal delivered by control input Y1
No galvanic insulation between this input and the supply
No-load voltage Supply voltage
Switching current mA < 10Maximum distance m 50Compatibility 2-wire sensors � with leakage current < 1 mA
References :pages 2/44 to 2/47
Dimensions :pages 2/44 and 2/46
Schemes :page 2/45
a.c. load d.c. loadCurve 1 Curve 2 Load limit curveElectrical durability of contacts on resistive load in millions of operating cycles
Reduction factor k for inductive loads (applies to values taken from durability curve 1)
A RE8-RB��BUTQ A RE8-RB��BUTQ1 L/R = 20 ms2 L/R with load protection diode3 Resistive load
Example:
An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.1 A and cos ϕ = 0.3.For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles.As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2.
For cos ϕ = 0.3: k = 0.6The electrical durability therefore becomes:1.5 106
operating cycles x 0.6 = 900 000 operating cycles.
10
1
0,1
0,010 1 2 3 4 5 6 7 8
A
Current broken in A
Mill
ions
of o
pera
ting
cycl
es 1
0,6
0,5
0,9
0,8
0,7
0,4
0,31 0,8 0,6 0,5 0,4 0,3 0,2
Power factor on breaking (cos ϕ)
Red
uctio
n fa
ctor
k 300
40
30
200
100
50
20
100,1 0,2 0,5 1 2 5 2010
1
2
3
A
Current in A
Vol
tage
in V
RE8
K
+
–
2/44
2
Functions,references,dimensions,schemes 2
Zelio Time - industrial timing relays 2
Single-function relays, optimum, relay output, width 22.5 mm
Output 1 C/O contactSingle timing range
Function diagramsFunction A Function C
Delay on energisation Timing after opening of control contact
Unit references (Sold in packs of 10)
Functions A CVoltages ��or � 24 V � � –
��110…240 V � – �
� 380…415 V – – –Timing ranges 0.05 s…0.5 s – – –
0.1 s…3 s RE8 TA61BUTQ – –
0.1 s…10 s RE8 TA11BUTQ RE8 RA11BTQ RE8 RA11FUTQ 0.3 s…30 s RE8 TA31BUTQ RE8 RA31BTQ RE8 RA31FUTQ3 s…300 s RE8 TA21BUTQ RE8 RA21BTQ RE8 RA21FUTQ20 s…30 min RE8 TA41BUTQ – RE8 RA41FUTQ
Weight (kg) 0.110 0.110 0.110
DimensionsDimensions
Rail mounting Screw fixing
U
RT
U
C
RT
5609
54
5609
54
89,5
80
82
22,5
78
Ø4
66
78
Characteristics :pages 2/42 and 2/43
Schemes :page 2/45
2/45
2
22
Function K Function DDelay on de-energisation (without auxiliary supply)
Symmetrical flashing, start with output in rest position
(1) If the device has been stored, de-energised, for more than a month, it must be energised for about 15 seconds in order to activate it. Subsequently, it only takes 80 ms to start the time delay. � If this time is not complied with, the relay remains energised indefinitely.
K D� �
� �
– –RE8 RB51BUTQ –– –
RE8 RB11BUTQ RE8 CL11BUTQRE8 RB31BUTQ –– –
– –0.110 0.110
SchemesConnection schemes Recommended application schemes
RE8 TA, CL
RE8 RA
RE8 RB
RE8 TA, CL
RE8 RA
Control of several relays with a single external control contact Connection of a ���� 2-wire sensorRE8 RA, RE8 PD
The external control contact C may be an electronic control device, for example a 2-wire sensor. In this case A1-A2 = � 24 V and the control device can only control up to a maximum of 4 relays.
Leakage current (open state) If < 1 mA.
U
RT
> 80 ms (1)
T T T T T T
U
R
5609
54
5609
54
A1 15 B1
18 16 A2
1815B
1
A2
A1
16
A1 15 Y1
18 16 A2
1815A
2A
1
16
A1 15 B1
18 16 A2
1815B
1
A2
A1
16
B1 A2
A1
A1
A2
Y1
start
Y1A2
Y1A2
Y1A2
A1A1 A1C
Y1
–
+
A1
A2
If
Characteristics :pages 2/42 and 2/43
Dimensions :page 2/44
2/46
2
Functions,references,dimensions,schemes 2
Zelio Time - industrial timing relays 2
Single-function relays, optimum, relay output, width 22.5 mm
Output 1 C/O contactSingle timing range
Function diagramsFunction H Function W
Timing on energisation
On-delay after opening of control contact
Unit references (Sold in packs of 10)
Functions H WVoltages ��or � 24 V � � –
��110…240 V � – �
� 380…415 V – – –Timing ranges 0.05 s…0.5 s – – –
0.1 s…3 s – – –0.1 s…10 s RE8 PE11BUTQ RE8 PD11BTQ RE8 PD11FUTQ 0.3 s…30 s RE8 PE31BUTQ RE8 PD31BTQ RE8 PD31FUTQ3 s…300 s RE8 PE21BUTQ RE8 PD21BTQ RE8 PD21FUTQ20 s…30 min – – –
Weight (kg) 0.110 0.110 0.110
Dimensions, schemesDimensions
Rail mounting
Screw fixing
Connection schemes (terminal blocks)
RE8 PE
RE8 PD
RE8 PT
RE8 YA
RE8 YG
U
R
T
T
U
C
R
5609
68
5609
68
89,5
80
82
22,5
78
Ø4
66
78
A1 15 B1
18 16 A2
1815
16
B1
A2
A1
A1 15 Y1
18 16 A2
1815A
2A
1
16
A1 15 B1
18 16 A2
1815
16
B1
A2
A1
A1 15 25
28 16 A2
1615A
2A
1
2825
A1 15 B1
18 16 A2
1815B
1A
2A
1
16
Characteristics :pages 2/42 and 2/43
Schemes :page 2/47
2/47
2
22
Function He Function Qc Function QePulse-on de-energisation
Star-delta timing
Star-delta timing
He Qc Qe� � � – –
� � – � –– – – – �
RE8 PT01BUTQ – – – –
– – – – –– RE8 YG11BUTQ – – –– RE8 YG31BUTQ RE8 YA32BTQ RE8 YA32FUTQ RE8 YA32QTQ– RE8 YG21BUTQ – – –– – – – –0.110 0.110 0.110 0.110 0.110
Recommended application schemesPulse-on energisation relays
RE8 PE, RE8 PT RE8 PD
Timing relays for star-delta startersRE8 YG, RE8 YA RE8 YG RE8 YA
(1) K1T: RE8 YG�1��TQ (1) K1T: RE8 YA32��TQ
Note : Correct operation of the star-delta starter associated with the RE8 YG is only possible if the wiring scheme is strictly complied with.
U
R
> 80 ms 80 msT > T T 50 ms
U
R
T 80 ms
U
R1
R2
5609
68
5609
69
5609
69
B1 A2
A1
A1
A2
Y1
+
start
– KM2 – KM3 – KM1
U1
V1
W1
U2
V2
W2
– Q1
L1 L2 L3
– Rth
Y
(1)
Y
A1
A2
A1
A2
A1
A2
A1
A2
16 15
L
(1)
(1)
Y
A1
A2
A1
A2
A1
A2
A1
A2
1516
2528
L
Characteristics :pages 2/42 and 2/43
Dimensions :page 2/46
2/48
2
Characteristics 2 Zelio Time - timing relays 2
Universal plug-in relays, 11-pin,relay output, width 35 mm
Timing characteristicsRepeat accuracy(with constant parameters)
Conforming to IEC 1812-1 ± 0.5 %
Drift Temperature ± 0.05 % / °CVoltage ± 0.2 % / V
Full scale setting accuracy Conforming to IEC 1812-1 ± 10 % at 25 °C
Minimum duration of control impulse
Typical ms 30Typical under load ms 100
Maximum reset timeby de-energisation
Typical ms 100
Immunity timeto microbreaks
Typical ms > 10
Supply characteristicsMultivoltage supply Depending on version, see pages 2/50 and 2/52
Frequency Hz 50/60Operating range 85…110 % Un (85…120 Un for �/��12 V )On-load factor 100 %
Maximum powerconsumption
Dependingon model
� 24 V W 0.6 � 240 V W 1.5� 240 V VA 32
Output characteristicsOutput type Relay, C/O contacts, AgNi (cadmium free)Breaking capacity � 2000 VA, ��80 WMaximum breaking current A ��8, �� 8
Minimum breaking current mA 10 /� 5 V Maximum switching voltage V �/��250Electrical life 105 operations 8 A 250 V resistive
Mechanical life 5 x 106 operationsDielectric strength Conforming to IEC 1812-1 kV 2.5/1min/1 mA/50 HzImpulse voltage Conforming to
IEC 664-1, IEC 1812-1kV 5, wave 1.2/50 µs
Display characteristicsState indication by 1 LED Green Operating status indication
Pulsing: relay energised, no timing in progress (except Di-D and Li-L)
Flashing: timing in progress
On steady: relay energised, no timing in progress
Input characteristicsInput type V Volt-free contact (no potential)
Control possible by 3-wire sensor with PNP output, maximum residual voltage: 0.4 V whatever the supply voltage of the timer
References :pages 2/50 and 2/52
Dimensions :page 2/50
Schemes :page 2/52
2/49
2
Characteristics (continued) 2 Zelio Time - timing relays 2
Universal plug-in relays, 11-pin,relay output, width 35 mm
General characteristicsConforming to standards IEC 1812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC
(� marking) + EMC (89/336/EEC + IEC 669-2-3)
Product certifications c UR us, CSA, GL
Temperature limits Operation °C - 20…+ 60
Storage °C - 30…+ 60
Creepage distanceand clearance
Conforming to IEC 60664-1 kV 4 kV/3
Degree of protectionconforming to IEC 529
Terminal block IP 20Enclosure IP 40Front panel IP 50
Vibration resistance Conforming to IEC 68-2-6 f = 10…55 HzA = 0.35 mm
Relative humiditywithout condensation
Conforming to IEC 68-2-3 93 %
Electromagneticcompatibility
Immunity to electrostatic discharge, conforming to IEC 1000-42
Level III (Air 8 kV/Contact 6 kV)
Immunity to electromagnetic fields, conforming to ENV 50140/204 (IEC 1000-4-3)
Level III 10 V/m : (80 MHz…1 GHz)
Immunity to fast transients in bursts, conforming to IEC 1000-4-4
Level III (direct 2 kV / capacitive connecting clip 1 kV)
Immunity to surges on the power supply, conforming to IEC 1000-4-5
Level III (common mode 2 kV / differential mode 1 kV)
Immunity to radio frequency interference in common mode conforming toENV 50141 (IEC 1000-4-6)
Level III (10 V rms : 0.15…80 MHz)
Immunity to voltage dips and breaks, conforming to IEC 1000-4-11
30 % / 10 ms60 % / 100 ms95 % / 5 s
Radiated and mains conducted disturbance,conforming to EN 55022 (EN 55011 Group 1)
Class B
Fixing Plug-in socket 11-pin
Enclosure material Self-extinguishing
References :pages 2/50 and 2/52
Dimensions :page 2/50
Schemes :page 2/52
2/50
2
References,dimensions,schemes 2
Zelio Time - timing relays 2
Universal plug-in relays, 11-pin,relay output, width 35 mm
Relay output, 2 C/O contacts� Multifunction, dual function or single function� Multi-range (7 switchable ranges)� Multivoltage� 2 relay outputs: 8 A - 250 V (10 A UL)� Plug-in� State indication by 1 LED� Option of supplying a load in parallel� 3-wire sensor control possible
Function diagramsFunction A Function C Function Ac
Delay on energisation2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous
Timing after opening of control contact2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous
Timing after closing and opening of control contact2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous
Function B Function Ht Function DiTiming on impulse, one shot2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous
Timing on energisation wih memory2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous
Symmetrical flashing, start with output in operating position2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous
References
Connection Plug-in sub-base � � �
Functions Multifunction Dual function Single functionA - At - B - C - H - Ht - Di - D Ac - Bw
A - At C
Timing ranges 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 hRelay output 2 timed contacts,
1 convertible to instantaneous2 timed contacts 2 timed contacts
Rated current 8 A 8 A 8 A
Voltages ��24 V / ��24…240 V RE 88 867 305 RE 88 867 415 RE 88 867 435�/��12 V – – –�/��12…240 V – – –
Weight (kg) 0.080 0.080 0.08011-pin socket (1)with connector
Mixed contact terminals (2) RUZ C3M RUZ C3M RUZ C3MWeight (kg) 0.054 0.054 0.054
(1) These products are sold in packs of 10(2) The inputs are mixed with the relay’s supply terminals, with the outputs being located on the
opposite side of the socket.
Dimensions and connection schemesDimensions
U
R1/R2
R2 instT
U
C
R1/R2
∞ TR2 inst.
U
C
R1/R2T T
R2 Inst.
U
C
R1/R2∞ T
R2 Inst.t1
R1/R2
C
U
t2
T = t1+t2R2 Inst.
U
R1/R2T T
R2 Inst.
5611
80
5611
81
5611
81
45
3,5 12,5
74,535
Characteristics :pages 2/48 and 2/49
Dimensions :page 2/52
2/51
2
2
Function Bw Function At Function H Function D Function LPulse output (width adjustable)2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous
Delay on energisation with memory2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous
Timing on energisation2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous
Symmetrical flashing, start with output in rest position2 timed contacts or 2 timed contacts, 1 of which convertible to instantaneous
Asymmetrical flashing,Start with output in rest position2 timed contacts
Function LiAsymmetrical flashing,start with output in operating position2 timed contacts
� � �
Dual function Multifunction MultifunctionLi - L A - At - B - C - H - Ht - Di - D - Ac - Bw A - At - B - C - H - Ht - Di - D - Ac - Bw
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h2 timed contacts 2 timed contacts,
1 convertible to instantaneous2 timed contacts,1 convertible to instantaneous
8 A 8 A 8 A
RE 88 867 455 – –– RE 88 867 300 –– – RE 88 867 3030.080 0.080 0.080RUZ C3M RUZ C3M RUZ C3M0.054 0.054 0.054
Connection schemesAll functions except L and Li Functions L and Li
U
C
RT T
U
C
R1/R2t1 t2
T = t1+t2R2 Inst.
TR1/R2
U
R2 Inst.
U
T TR1/R2
R2 Inst.T1
R1/R2T2
U
T1R1/R2
U
T2
5611
80
5611
82
5611
82
U
4R1
Y1
R2
+
–
56
7
8
9
10111
2
3
U
(1)
4R1 R2
+
–
56
7
8
9
10111
2
3
Characteristics :pages 2/48 and 2/49
Dimensions :page 2/50
(1) Link between pins 2 and 5 for function L only.
2/52
2
Characteristics 2 Zelio Time - timing relays 2
Universal plug-in relays, 8-pin,relay output, width 35 mm
Timing characteristicsRepeat accuracy(with constant parameters)
Conforming to IEC 1812-1 ± 0.5 %
Drift Temperature ± 0.05 % / °CVoltage ± 0.2 % / V
Full scale setting accuracy Conforming to IEC 1812-1 ± 10 % at 25 °C
Minimum duration of control impulse
Typical ms 30Typical under load ms 100
Maximum reset time by de-energisation
Typical ms 100
Immunity timeto microbreaks
Typical ms > 10
Supply characteristicsMultivoltage supply Depending on version, see pages 2/54 and 2/55Frequency Hz 50/60Operating range 85…110 Un % (85…120 Un for �/��12 V )
On-load factor 100 %Maximum power consumption
Depending on model
� 24 V W 0.6 � 240 V W 1.5
� 240 V VA 32
Output characteristicsOutput type Relay, 1 or 2 C/O contacts, AgNi (cadmium -free)Breaking capacity � 2000 VA, ��80 W
Maximum breaking current A ��8, �� 8Minimum breaking current mA 10/� 5 V Maximum switching voltage V �/��250
Electrical life 105 operations 8 A 250 V resistive Mechanical life 5 x 106 operationsDielectric strength Conforming to IEC 1812-1 kV 2.5/1min/1 mA/50 Hz
Impulse voltage Conforming to IEC 664-1,IEC 1812-1
kV 5, wave 1.2/50 µs
Display characteristicsState indication by 1 LED Green Operating status indication
Pulsing: relay energised, no timing in progress (except Di-D and Li-L)
Flashing: timing in progress
On steady: relay energised, no timing in progress
Input characteristicsInput type V Volt-free contact (no potential)
Control possible by 3-wire sensor with PNP output, maximum residual voltage: 0.4 V whatever the supply voltage of the timer
References :pages 2/54 and 2/55
Dimensions :page 2/54
Schemes :page 2/55
2/53
2
Characteristics (continued) 2 Zelio Time - timing relays 2
Universal plug-in relays, 8-pin,relay output, width 35 mm
General characteristicsConforming to standards IEC 1812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC
(� marking) + EMC (89/336/EEC + IEC 669-2-3)
Product certifications c UR us, CSA, GL
Temperature limits Operation °C - 20…+ 60
Storage °C - 30…+ 60
Creepage distanceand clearance
Conforming to IEC 60664-1 kV 4 kV/3
Degree of protectionconforming to IEC 529
Terminal block IP 20Enclosure IP 40Front panel IP 50
Vibration resistance f = 10…55 HzA = 0.35 mm
Relative humiditywithout condensation
Conforming to IEC 68-2-3 93 %
Electromagneticcompatibility
Immunity to electrostatic discharge, conforming to IEC 1000-42
Level III (Air 8 kV/Contact 6 kV)
Immunity to electromagnetic fields, conforming toENV 50140/204 (IEC 1000-4-3)
Level III 10 V/m : (80 MHz…1 GHz)
Immunity to fast transientsin bursts conforming to IEC 1000-4-4
Level III (direct 2 kV / capacitive connecting clip 1 kV)
Immunity to surges on the power supply, conforming toIEC 1000-4-5
Level III (common mode 2 kV / differential mode 1 kV)
Immunity to radio frequency interference in common mode conforming to ENV 50141(IEC 1000-4-6)
Level III (10 V rms : 0.15…80 MHz)
Immunity to voltage dips and breaks conforming to IEC 1000-4-11
30 % / 10 ms60 % / 100 ms >95 % / 5 s
Radiated and mains conducted disturbanceconforming to EN 55022(EN 55011 Group 1)
Class B
Fixing Plug-in socket 8-pin
Enclosure material Self-extinguishing
References :pages 2/54 and 2/55
Dimensions :page 2/54
Schemes :page 2/55
2/54
2
References,dimensions,schemes 2
Zelio Time - timing relays 2
Universal plug-in relays, 8-pin,relay output, width 35 mm
Relay output, 1 or 2 C/O contacts� Multifunction of single function� Multi-range (7 switchable ranges)� Multivoltage� 1 or 2 relay outputs: 8 A - 250 V (10 A UL)� Plug-in� State indication by 1 LED� Option of supplying a load in parallel� 3-wire sensor control option
Function diagramsFunction A Function C
Delay on energisation1 contact
2 timed contacts
Timing after opening of control contact1 timed contact
Function Di Function B Function HtSymmetrical flashing, start with output in operating position
Timing on impulse, one shot
Timing on energisation with memory
References
Connection Plug-in sub-base � � �
Functions Multifunction Single function Single functionA - At - B - C - H - Ht - Di - D Ac - Bw
A C
Timing ranges 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
Relay output 1 timed contact 2 timed contacts 1 timed contactRated current 8 A 8 A 8 AVoltages ��24 V / ��24…240 V RE 88 867 105 RE 88 867 215 RE 88 867 135
�/��12 V – – –�/��12…240 V – – –
Weight (kg) 0.080 0.080 0.080
8-pin socket (1)with connector
Mixed contact terminals (2) RUZ C2M RUZ C2M RUZ C2MWeight (kg) 0.054 0.054 0.054
(1) These products are sold in packs of 10.(2) The inputs are mixed with the relay’s supply terminals, with the outputs being located on the
opposite side of the socket.
Dimensions and connection schemesDimensions
U
RT
U
R1/R2T
U
C
R∞ T
U
RT T
U
C
R∞ T t1
R
C
U
t2T = t1+t2
5611
77
5611
78
5611
78
45
3,5 12,5
74,535
Characteristics :pages 2/52 and 2/53
Schemes :page 2/55
2/55
2
22
Function L Function D Function At Function H Function LiAsymmetrical flashing,start with output in rest position
Symmetrical flashing,start with output in rest position
Delay on energisationwith memory
Timing on energisation
Asymmetrical flashing,start with output in operating position
Function Ac Function BwTiming after closing and opening of control contact
Pulse output (width adjustable)
� � �
Dual function Multifunction MultifunctionLi - L A - At - B - C - H - Ht - Di - D - Ac - Bw A - At - B - C - H - Ht - Di - D - Ac - Bw
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
1 timed contact 1 timed contact 1 timed contact8 A 8 A 8 ARE 88 867 155 – –
– RE 88 867 100 –– – RE 88 867 1030.080 0.080 0.080
RUZ C2M RUZ C2M RUZ C2M0.054 0.054 0.054
Connection schemesTiming relays with 1 relay outputAll functions except L and Li Functions L and Li
(1) Link between pins 2 and 6 for function L only.
Timing relays with 2 relay outputsFunction A
T1R
T2
U U
T TR
U
C
Rt1 t2
T = t1+t2
TR
U
T1R
U
T2
U
C
RT T
U
C
RT T
5611
79
5611
78
5611
78
U4
R
+
–
5
6
7
81
2
3
Y U (1)4
R
+
–
5
6
7
81
2
3
U4
R1 R2
+
–
5
6
7
81
2
3
Characteristics :pages 2/52 and 2/53
Dimensions :page 2/54
2/56
2
Characteristics 2 Zelio Time - timing relays 2
Miniature plug-in relays, relay output
Timing characteristicsRepeat accuracy (with constant parameters) ± 0.5 %Full scale setting accuracy Conforming to IEC/EN 61812-1 10 % at 25 °CTemperature drift 0.05 %/ °C
Maximum reset timeby de-energisation
During time delay period ms 50After time delay period ms 250
Immunity to microbreaks ms ≤ 5
Voltage drift ± 0.2 % / V
Output characteristicsOutput type Relay 2 and 4 cadmium-free C/O contacts
Rated current A � 5Rated insulation voltage V � 250Maximum breaking capacity (resistive) A 4 x 5
Maximum permissible current A 10 < 0.01 sMinimum breaking current mA 100Electrical life at I max ���� 250 V resistive 105 operating cycles
Mechanical life 107 operationsDielectric strength To IEC/EN 61812-1 and 60601-1 2 kV at 1 mA for 1 min at 50 Hz
General characteristicsConforming to standards IEC/EN 61812-1, 60601-1, 60601-2, EN 50081-2, 61000-6-2,
LV (73/23/EEC + 93/68/EEC) + EMC (89/336/EEC) directives
Product certifications UL-cULState indication by LED Output in operation Red LED
Power on Yellow LED
Permissible voltage variation � 12 V ± 10 %� 24 V ± 10 %��24 V ± 15 %
��120 V ± 15 %��230 V ± 15 %
Frequency Hz 50/60 ± 1
Maximum power consumption � 12 V W 1.5 �� 24 V W 1.2 ��24 V VA 1.7 �
��120 V VA 2.6 ���230 V VA 3
Temperature limits Operation °C - 20…+ 60
Storage °C - 40…+ 70Insulation voltage To standard VDE 0010
IEC 255 Group CV �/� 250
Degree of protection Conforming to IEC 60529 IP 50Overvoltage protection joules 2
Fixing Base-mounted On socketVibration resistance Conforming to IEC 60068-2-6,
10 to 55 Hza = 0.35 mm
Relative humidity Conforming to IEC 60068-2-3without condensation
95 % max
Immunity to electromagnetic interference (EMC) (application class 2 conforming to EN 61812-1/A11)Electrostatic discharge Conforming to IEC/EN 61000-4-2 Level 3 (Air 8 kV contact, 6 kV)
Electromagnetic fields Conforming to IEC/EN 61000-4-3 Level 3 (10 V/m)Fast transients Conforming to IEC/EN 61000-4-4 Level 3 (2 kV)Shock waves Conforming to IEC/EN 61000-4-5 Level 3 (2 kV)
Radio frequenciesin common mode
Conforming to IEC/EN 61000-4-6 Level 3 (10 V rms from 0.15 MHz to 80 MHz)
Voltage dips and breaks Conforming to IEC/EN 61000-4-11 30 %/10 ms, 60 %/100 ms and 1 s, > 95 %/5 sRadiated and conducted emissions
Conforming to EN 55022(EN 55011 group 1)
Class B
Creepage distanceand clearance
Conforming to IEC 60664-1 kV 4, in category 3
Internal schemesRelay with 4 C/O contacts
Relay with 2 C/O contacts
- 13
9
5 1
+ 14
6
10
2
11
7 3
12
8 4 - 13
9
5 1
+ 14
8
12
4
References :page 2/57
Dimensions :page 2/57
2/57
2
Functions,references,dimensions 2
Zelio Time - timing relays 2
Miniature plug-in relays, relay output
Relay output, 2 and 4 C/O contacts� Miniature and plug-in (21 x 27 mm)� Function A : on-delay� 7 timing ranges: 0.1 s to 100 h� Excellent immunity to interference� Power on and relay energised indication by 2 LEDs
Function diagramsFunction A
Delay on energisation4 timed C/O contacts
2 timed C/O contacts
References
Functions Single function A
Timing ranges 7 switchable ranges 0.1 s…1 s - 1 s…10 s - 0.1 min…1 min - 1 min…10 min - 0.1 h…1 h - 1 h…10 h - 10 h…100 hRelay output 4 timed C/O contacts 2 timed C/O contactsRated current ��5 A ��5 A
Voltages ��12 V RE XL4TMJD RE XL2TMJD��24 V (1) RE XL4TMBD RE XL2TMBD��24 V 50/60 Hz (1) RE XL4TMB7 RE XL2TMB7��120 V 50/60 Hz RE XL4TMF7 RE XL2TMF7��230 V 50/60 Hz RE XL4TMP7 RE XL2TMP7
Weight (kg) 0.050 0.050
Sockets (2) with mixed contact terminals (3)
With screw clamp terminals RXZ E2M114 (5) RXZ E2M114 (5)Weight (kg) 0.048 0.048With connector RXZ E2M114M (5) RXZ E2M114M (5)
Weight (kg) 0.056 0.056Sockets (2) withseparate contact terminals (4)
With connector RXZ E2S114M (6) RXZ E2S108M (6)Weight (kg) 0.058 0.070
(1) For � 48 V supply, additional resistor 560 Ω 2 W / ��24 V. For ��48 V supply, additional resistor 390 Ω 4 W / ��24 V.(2) These products are sold in lots of 10.(3) The inputs are mixed with the relay’s supply terminals, with the outputs being located on the
opposite side of the socket.(4) The inputs and outputs are separated from the relay supply terminals.(5) Thermal current Ith: 10 A(6) Thermal current Ith: 12 A
Dimensions and terminal referencingDimensions Terminal referencing
RE XL4TM��������
13-14
1-5-9
4-8-12T
2-6-10
3-7-11
13-14
1-5-9
4-8-12T
5325
35
5325
36
27
21
27
21
RE XL2TM��������
R Un
21 65,53,5
27
59,5
0,55
2,8
0,31,2
159
13
(-)
26
10
37
11
48
1214
(+)
159
13
(-)
48
1214
(+)
Characteristics :page 2/56
Schemes :page 2/56
2/58
2
Presentation 2 Zelio Time - timing relays 2
Electronic relays, relay output, 48 x 48 housing
The range of RE 48A timing relays, in 48 x 48 housing, is specially designed for integration in machines and equipment. It is suitable for applications requiring frequent modification or adjustment of the timing cycles.
RE 48A relays have the following characteristics:� All references are multivoltage 24 to 240 V � and � and are therefore suitable for the majority of applications while at the same time reducing the number of products to be stocked.
� The timing ranges covered are from 0.02 s to 300 h.
� These timing relays can be panel-mounted using the spring clip supplied as standard, or DIN rail-mounted using standard sockets.
� Two LED's on the front face provide immediate indication of the timing status: � power ON,� output relay state,� timing in progress.
The size of the knob and clear indication of the timing scale allow easy adjustment, eliminating any errors during parameter setting.In addition, in applications where only the timing cycle value is left freely accessible to users, a protective cover can be used to block access to the other settings.
This range is comprises 4 references:
(1) This relay features control inputs which provide a wider choice of timing modes:Start Input to control the start of timing,Gate Input to suspend the timing in progress without cancelling it,Reset Input to reset timing to its initial state during the cycle.
Presentation
Reference DescriptionRE 48A TM12MW Single function
� On-delay� two relay outputs
RE 48A CV12MW Dual function� asymmetrical flasher� two relay outputs
RE 48A MH13MW Multifunction� On-delay and pulse-on energisation� two relay outputs, of which one selectable and
instantaneous
RE 48A ML12MW (1) Multifunction� On-delay� timing on impulse� Off-delay� symmetrical flasher
Characteristics : pages 2/60 and 2/61
Function diagrams :page 2/62
References :pages 2/63 and 2/64
Dimensions :pages 2/63 and 2/64
Mounting :page 2/65
2/59
2
Description 2 Zelio Time - timing relays 2
Electronic relays, relay output, 48 x 48 housing
DescriptionRE 48A TM12 MW timing relays have the following on the front face :
1 A time base selector knob (12 and 30)2 A time unit selector knob (x 0.1 s, x 1 s, x 10 s, x 1 min, x 10 min, x 1 h, x 10 h)3 A timing adjustment knob4 A yellow LED, indicating the status of the output relay5 A green LED, indicating power ON (flashing during the timing period).
RE 48A CV12 MW timing relays have the following on the front face :
1 A time base selector knob (12 and 30)2 Two time unit selector knobs (x 0.1 s, x 1 s, x 10 s, x 1 min, x 10 min, x 1 h,
x 10 h)3 An orange button for setting the pulse time4 A white button for setting the pause time5 A yellow LED, indicating the status of the output relay6 A green LED, indicating power ON (flashing during the timing period).
RE 48A M�1� MW timing relays have the following on the front face :
1 A time base selector knob (12 and 30)2 A time unit selector knob (x 0.1 s, x 1 s, x 10 s, x 1 min, x 10 min, x 1 h, x 10 h)3 A function selector knob:
A, B, C, Di for RE 48A ML12 MWA1, A2, H1, H2 for RE 48A MH13 MW
4 A timing adjustment knob5 A yellow LED, indicating the status of the output relay6 A green LED, indicating power ON (flashing during the timing period).
1
5
4 3 2
5219
34
1
6
3
25 24
5219
35
1
45
6
23
5219
36
Characteristics : pages 2/60 and 2/61
Function diagrams :page 2/62
References :pages 2/63 and 2/64
Dimensions :pages 2/63 and 2/64
Mounting :page 2/65
2/60
2
Characteristics 2 Zelio Time - timing relays 2
Electronic relays, relay output, 48 x 48 housing
General characteristicsConforming to standards IEC 61812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC
�����marking) + EMC directive (89/336/EEC + IEC 60669-2-3)
Approvals UL, cULus, C-Tick, CSA, GL
Ambient air temperature around the device
Storage °C - 40…+ 70
Operation °C - 20…+ 50
Degree of protectionconforming to IEC 60529
Housing IP 40Front face IP 50
Vibration resistance Conforming to IEC 60068-2-6 f = 10…55 HzA = 0.35 mm
Relative humidity without condensation
Conforming to IEC 60068-2-3 93 %
Electromagnetic compatibility Immunity to electrostatic discharge,conforming to IEC/EN 61000-4-2
Level III (Air 8 kV/Contact 6 kV)
Immunity to electromagnetic fieldsconforming to IEC/EN 61000-4-3
Level III (10 V/m: 26 MHz…1 GHz)
Immunity to fast transients in bursts,conforming to IEC/EN 61000-4-4
Level IV (direct 4kV / capacitive connecting clip 2 kV)
Immunity to surges on the power supplies,conforming to IEC 61000-4-5
Level III (common mode 2 kV / differential mode 1 kV)
Immunity to radio frequency interference in common mode, conforming to IEC/EN 61000-4-6
Level III (10 V rms: 0.15…80 MHz)
Immunity to voltage dips and breaks,conforming to IEC/EN 61000-4-11
30 % / 10 ms60 % / 100 ms95 % / 5 s60 % / 1 s
Radiated and mains conducted disturbance,conforming to EN 55022 (EN 55011 Group 1)
Class B (0.15...30 MHz)
Fixing Panel-mounting Using mounting system (supplied with the product)Base-mounted With socket
Connection By socket or connector
Housing material Self-extinguishing
Input characteristicsType of input by volt-free contact
Start: starts the function (only for functions A, B, C and Di on RE 48A ML12 MW)Gate: stops timing in progressReset: resets the relay, output to OFF
Output characteristicsOutput type Relay with 2 timed changeover contacts (except RE 48A MH13 MW: relay with
1 timed changeover contact and 1 instantaneous changeover contact) Contact type AgNi (cadmium-free)
Breaking capacity VA � 1250Maximum breaking current A � 5 for 250 VMinimum breaking current mA 100/� 12 V
Maximum switching voltage V �/� 250Electrical durability 105 operationsMechanical durability 30 x 106 operations
Dielectric strength Conforming to IEC 61812-1 kV 1/1minElectric shock resistance Conforming to
IEC 60664-1, IEC 61812-1kV 4, category 3
Rated operational voltage � AC-12 Ue = 240 V and Ie = 5 A� AC-15 Ue = 240 V and Ie = 1.5 A
� DC-13 Ue = 30 V and Ie = 2 A
Presentation, description : pages 2/58 and 2/59
Function diagrams :page 2/62
References :pages 2/63 and 2/64
Dimensions :pages 2/63 and 2/64
Mounting :page 2/65
2/61
2
Characteristics 2 Zelio Time - timing relays 2
Electronic relays, relay output, 48 x 48 housing
Supply characteristicsSupply voltage V �/��24…240
Frequency Hz 50/60
Operating range � - 15 %...+ 10 %� - 10 %...+ 10 %
On-load factor 100 %
Maximum power consumption
Depending on model
� 24 V W 0.5� 24 V VA 1.1 � 240 V W 1.7
� 240 V VA 4.8
Timing characteristicsSelectable timing ranges by selector switch on front face s
Time unit Time scale0.02…1.2 x 0.1 s 12
0.05…3 x 0.1 s 300.2…12 x 1 s 120.5…30 x 1 s 30
2…120 x 10 s 125…300 x 10 s 30
min 0.2…12 x 1 min 12
0.5…30 x 1 min 302…120 x 10 min 125…300 x 10 min 30
h 0.2…12 x 1 h 120.5…30 x 1 h 302…120 x 10 h 12
5…300 x 10 h 30
Repeat accuracy(with constant parameters)
Conforming to IEC 61812-1 ± 0.2 % of the maximum setting value
Driftconforming to IEC 61812-1
Temperature ± 0.02 %/°C of the maximum setting valueHumidity ± 0.05 %/%HR of the maximum setting valueVoltage �/� 24...48 V: ± 1 %/V of the maximum setting value
�/� 48...240 V: ± 0.2 %/V of the maximum setting valueSetting accuracy at full scale Conforming to IEC 61812-1 ± 5 % at 25 °C
Minimum control pulse duration on the Gate/Start/Reset input
Typical ms 20
Minimum reset time by de-energisation ms 25
Delay on pick-up ms 55
Immunity to microbreaks ms < 10
Display characteristicsState indication Green LED Flashing: timer energised, timing in progress
On steady: timer energised, relay energised, no timing in progressYellow LED On: output relay ON
Off: output relay OFF
Presentation, description : pages 2/58 and 2/59
Function diagrams :page 2/62
References :pages 2/63 and 2/64
Dimensions :pages 2/63 and 2/64
Mounting :page 2/65
2/62
2
Functions 2 Zelio Time - timing relays 2
Electronic relays, relay output, 48 x 48 housing
Function diagramsRE 48A TM12 MW RE 48A CV12 MWFunction A Function L Function Li
Delay on energisation Asymmetrical flashing, start with output in rest position
Asymmetrical flashing, start with output in operating position
RE 48A ML12 MWFunction A Function B
Delay on energisation Timing on impulse, one shot
Function C Function DiTiming after opening of control contact Symmetrical flashing, start with output in operating position
RE 48A MH13 MWFunctions A1, A2 Functions H1, H2
Delay on energisation Pulse-on energisation
Note : If A1 or H1 are selected, only R2 is timed, R1 is instantaneous
T T
Un
R
t3 ta tc
t2 tb
t1
Un
Gate
2 - 6Nor / Inv
Toff
Ton
Toff = t1+t2+t3 Ton = ta+tb+tc
R
Toff Toff
Ton
t3 ta
t2 tb
t1 t1
Un
Gate
2 - 6Nor / Inv
Ton
Ton = t1+t2+t3 Toff = ta+tb+tc
R
Toff
Ton
T Tt2
T = t1 + t2 + t3
t1 t3 T T T Tt
Un
Start
Gate
Reset
R
T T T t1 t3
t2
T = t1 + t2 + t3
T T T
Un
Start
Gate
Reset
R
T T t1 t3
t2T = t1 + t2 + t3
T T
Un
Start
Gate
Reset
Output
T T T T T Tt1t2
T = t1 + t2
t1 t2 T T T T T T T T TT T T TT
Un
Start
Gate
Reset
Output
T T
Un
R2
R1
T T
Un
R2
R1
Presentation, description : pages 2/58 and 2/59
Characteristics : pages 2/60 and 2/61
References :pages 2/63 and 2/64
Dimensions :pages 2/63 and 2/64
Mounting :page 2/65
2/63
2
References,dimensions 2
Zelio Time - timing relays 2
Electronic relays, relay output, 48 x 48 housing
References
Plug-in 8-pin 11-pin 11-pin 8-pinFunctions Single function Dual function Multifunction Multifunction
A L, Li A, B, C, Di A1, A2, H1, H2
Timing ranges 1.2 s, 3 s, 12 s, 30 s, 120 s, 300 s, 12 min, 30 min, 120 min, 300 min, 12 h, 30 h, 120 h, 300 hRelay output 2 C/O timed contacts 2 C/O timed contacts 2 C/O timed contacts 1 C/O timed contact
1 C/O instantaneous contact
Rated current 2 x 5 A 2 x 5 A 2 x 5 A 2 x 5 AVoltages �/��24…240 V RE 48A TM12 MW RE 48A CV12 MW RE 48A ML12 MW RE 48A MH13 MWWeight (kg) 0.140 0.140 0.140 0.140
DimensionsRE 48A �������� 1���� MW
4844,4
Ø39
6,8 64,5 15,5 48
96,8
Presentation, description : pages 2/58 and 2/59
Characteristics : pages 2/60 and 2/61
Mounting :page 2/65
5219
38
5219
37
5219
39
5219
39
2/64
2
References,dimensions 2
Zelio Time - timing relays 2
Electronic relays, relay output, 48 x 48 housing
ReferencesDescription Number
of pinsFor use with
Sold in lot of
Unit reference
Weightkg
IP 20 socketswith screw terminal connections and mixed contact terminals (1)
8 RE 48A TM12 MW, RE 48A MH13 MW
10 RUZ C2M 0.054
11 RE 48A CV12 MW, RE 48A ML12 MW
10 RUZ C3M 0.054
IP 20 socket with screw terminal connections on rear face
11 RE 48A CV12 MW, RE 48A ML12 MW
1 RE 48A SOC11 AR –
IP 20 solder connectors
8 RE 48A TM12 MW, RE 48A MH13 MW
1 RE 48A SOC8 SOLD –
11 RE 48A CV12 MW, RE 48A ML12 MW
1 RE 48A SOC11 SOLD –
Setting protection cover
– RE 48A TM12 MWRE 48A CV12 MW RE 48A ML12 MW RE 48A MH13 MW
1 RE 48A SET COV –
IP 64 protective cover – RE 48A TM12 MWRE 48A CV12 MW RE 48A ML12 MW RE 48A MH13 MW
1 RE 48A IP COV –
(1) The inputs are mixed with the relay’s supply terminals, with the outputs being located on the opposite side of the socket.
RUZ C3M
RE 48A SOC11 AR
RE 48A SOC8 SOLD RE 48ASOC11 SOLD
RE 48A SET COV RE 48A IP COV
DimensionsCommon side view 8-pin socket 11-pin socketRUZ C����M RUZ C2M RUZ C3M
11-pin socket 8-pin connector 11-pin connectorRE 48A SOC11 AR RE 48A SOC8 SOLD RE 48A SOC11 SOLD
75
27
22
38
30
24
6
27
A2
7
A1
2
11
1
21
8
A2
7
INPUT A2INPUT A1
22
5
12
4
1
4
2
3
8
5
7
6
14
3
2xØ3,1
37
38
37
30
A2
10
A2
10
31
11
21
6
11
1
A1
2
34
9
32
8
24
7
22
5
14
3
12
4
210
1
6
2
5
3
4
1110
7
9
8
INPUT A2INPUT A1
2xØ3,1
==
46
4620
Ø30
34
Ø30
34
Presentation, description : pages 2/58 and 2/59
Function diagrams :page 2/62
Characteristics : pages 2/60 and 2/61
2/65
2
Mounting,schemes 2
Zelio Time - timing relays 2
Electronic relays, relay output, 48 x 48 housing
MountingCover positioning and mounting Panel cut-out
e : panel thickness(1) IP 64 protective cover: RE 48A IP COV(2) Panel mounting frame(3) Locating screw
n : Number of devices mounted side-by-side
Connection schemesRE 48A TM12 MW RE 48A CV12 MW RE 48A ML12 MW RE 48A MH13 MW
e (2)
(3)17
20
(1)
15
30
1
U
R2
3
4 5
8
7
6
6 75 84
93
111
102
U
R
Gate 6 75 84
93
111
102
U
R
Reset
Start
Gate1
U
R1 R22
3
4 5
8
7
6
Presentation, description : pages 2/58 and 2/59
Function diagrams :page 2/62
Characteristics : pages 2/60 and 2/61
2/66
2
Characteristics 2 Zelio Time - timing relays 2
Panel-mounted, plug-in, universal relays
Display characteristicsNumber of digits 4Digit height mm 8
Timing characteristicsRepeat accuracy (with constant parameters) ± 0.03 % ± 20 ms
Full scale setting accuracy ± 0.03 % ± 20 msMinimum duration of control impulse ms 50Maximum reset time byde-energisation
During time delay period ms 50
After time delay period ms 50
Output characteristicsRelay type RE 88 857 40�������� RE 88 857 10����
RE 88 857 00���� RE 88 857 30��������
Rated current A ��5, ��5 ��8, ��8 ��8, ��8Maximum switching voltage V ��250, ��30 ��250, ��30 ��250, ��30
Maximum breaking capacity on resistive load
� VA 1250 2000 2000� W 120 190 190
Maximum permissible current A 15 < 0.01 s
Minimum current mA 100Electrical life at I max, ���� 250 V resistive 105 cyclesMechanical life 5 million operating cycles
General characteristicsConforming to standards IEC 255, VDE 0435-2021Product certifications c UR us, CSAPermissible voltage variation - 15…+ 10 % - 15…+ 10 % - 15…+ 10 %
Immunity to microbreaks s < 0.03 < 0.03 < 0.03Maximum powerconsumption
��12 V W – 0.5 0.��24 V W 0.5 0.5 0.5
��48 V W – 1 1��24 V VA 1 1 1��48 V VA – 2 2
��110 V VA 3.5 3.5 3.5��220 V VA 11 11 11
Temperature limits Operation °C - 10…+ 60
Storage °C - 30…+ 70Front panel degree of protection IP 65Insulation Conforming to standard VDE 0110 and IEC 225 Group C
Protection class Conforming to UTE C 20010, IEC 529, DIN 40050Fixing Panel-mounted By clip
Base-mounted On socket
Material Self-extinguishing UL 94 grade Vo
Functions :page 2/68
Schemes :page 2/67
References :page 2/69
Dimensions :page 2/69
2/67
2
Schemes 2 Zelio Time - timing relays 2
Panel-mounted, plug-in, universal relays
Internal schemesRelay RE 88 857 40����
Relay RE 88 857 10����
Relay RE 88 857 00����
Relay RE 88 857 30����
Terminal referencing
(1) Another load may be connected.
RelayRE 88 57 40��������
RE 88 857 10��������
RE 88 857 00��������
RE 88 557 30��������
Supply 2-10 – � – �
Supply 2-7 � – � –Link 2-11 : � 12 V or �/� 24 V – � – –Link 2-7 : � 12 V or �/� 24 V – – – �
Link 2-8 : � 12 V or �/� 24 V – – � –2-5 or 2-6 control or reset contact – � � �
1-3-4 timed output contact � � � �
8-5-6 timed output contact � – – –8-9-11 timed or instantaneous output contact – – – �
7
2 1
3 4
8
6 5
1
10 3 4
5 2
-
+
11 1
7 3 4
6 2
-
+
8 1
10 3 4
11
9 8
2
-
+
7
6
781
2
34 5
~+U
~
+~
9
U
6 78
10111
234
5
-~
Start
(1) 6
7
812
34 5
~+U
~
Start
(1) 9
U
6 78
10111
234
5
~+
~
(1)
Reset
Characteristics :page 2/66
Functionspage 2/68
References :page 2/69
Dimensions :page 2/69
2/68
2
Functions 2 Zelio Time - timing relays 2
Panel-mounted, plug-in, universal relays
Relay output, 1 or 2 contacts� Multifunction or single function� Multi-range� Multivoltage � 1 or 2 relay outputs� Reset function on front panel (RE 88 857 30����)� Memory in the event of mains power failure (RE 88 857 30����)� Locking of access to programming(RE 88 857 10���� and RE 88 857 00����)� Upcount or downcount mode� Internal supply by lithium battery (10 years at 20 °C)
Function diagramsFunction A Function A1 Function A2
Delay on energisation1 timed contact
Delay on energisation1 timed contact1 instantaneous contact
Delay on energisation2 timed contacts
Function AM Function AMt Function BDelay on energisationMemory during the time delay period. Reset
Delay on energisationMemory during and after the time delay period. Reset
Timing on impulse, one shot
Function C Function D Function DiOff-delay
Flashing relay
Flashing relay
Function HTiming on energisation
2-10
1-3-4
T
2-10
8-9-11
Tt1<T t2<T
1-3-4
2-10
1-3-4
8-9-11
Tt1<T t2<T
2-5
Tt1 T=t1+t2
1-3-4
8-9-11
t
2-10
t2
2-5
Tt1 T=t1+t2
1-3-4
8-9-11
2-10
t2
2-10
2-5
T
1-3-4∞
2-10
2-5
1-3-4∞ T
2-10
1-3-4
T T T T T
2-10
1-3-4
T T T T T
2-10
1-3-4
T
Characteristics :page 2/66
Schemes :page 2/67
References :page 2/69
Dimensions :page 2/69
2/69
2
References,dimensions 2
Zelio Time - timing relays 2
Panel-mounted, plug-in, universal relays
References
Plug-in 8-pin 11-pin 8-pin 11-pinFunctions Single function Multifunction Multifunction Multifunction
A A, B, C, D, Di, H A, B, C, D, Di, H A1, A2, AM, AMtTiming ranges 99.99 s, 999.9 s, 9999 s, 99 min 59 s, 99.99 min, 999.9 min, 9999 min, 99 h 59 min, 99.99 h,
999.9 h, 9999 hRelay output 2 timed C/O
contacts1 timed C/O contact 1 timed C/O contact 1 timed C/O contact
1 timed or instantaneousC/O contact
Rated current 2 x 5 A 8 A 8 A 2 x 8 A
Voltages ��12 V and ��or�� 24…48 V – RE 88 857 103 RE 88 857 003 –��12 V and ��or�� 42…48 V – – – RE 88 857 302��or���24 V RE 88 857 409 – – –
��or���24 V and � 110 V – – – RE 88 857 307� or�� 24 V and � 110…240 V – RE 88 857 105 RE 88 857 005 –� or�� 24 V and � 220…240 V – – – RE 88 857 301��110 V RE 88 857 406 – – –��220…240 V RE 88 857 400 – – –
Weight (kg) 0.140 0.100 0.100 0.140
Socket (1) 8-pin RUZ 1D – RUZ 1D –11-pin – RUZ 1A – RUZ 1AWeight (kg) 0.067 0.067 0.067 0.067
(1) These products are sold in packs of 10.
Dimensions
Panel cut-out
5611
90
5611
91
5611
91
5611
92
48
48
9,71674,2
VALID MODE
45+0.6 0
45+
0.6
0
Characteristics :page 2/66
Schemes :page 2/67
Functions :page 2/68
2/70
2
Characteristics,schemes 2
Zelio Time - timing relays 2
Panel-mounted, plug-in, universal relays
Display characteristicsNumber of digits 4Digit height mm 7
Timing characteristicsRepeat accuracy (with constant parameters) ± 0.03 % ± 20 msFull scale setting accuracy ± 0.03 % ± 20 msMinimum duration of control impulse ms 50
Maximum reset timeby de-energisation
During time delay period ms 50After time delay period ms 50
Output characteristicsRated current A ��8, ��8Maximum switching voltage V ��250, ��30Maximum breaking capacity on a resistive load � VA 2000
� W 190Maximum permissible current A 15 < 0.01 sMinimum current mA 100
Electrical life at I max ���� 250 V resistive 100 000 operating cyclesMechanical life 5 million operating cycles
General characteristicsProduct certifications u UR cs, CSAConforming to standards IEC 255, VDE 0435-2021Permissible voltage variation - 15 …+ 10 %
Immunity to microbreaks s < 0.03Maximum powerconsumption
� 24 V W 0.5� 48 V W 1.5
��24 V VA 1��48 V VA 1.5��110 V VA 4
��230 V VA 12Temperature limits Operation °C - 10…+ 60
Storage °C - 30…+ 70
Front panel degree of protection IP 65Insulation Conforming to standards VDE 0110 and IEC 225 Group CProtection class Conforming to standards UTE C 20010, IEC 529, DIN 40050
Fixing Panel-mounting By clipBase-mounted On socket
Material Self-extinguishing UL 94 grade Vo
Internal schemesTerminal referencing
(1) Another load may be connected.
8-pin relay
11-pin relay
2-10 or 2-7 supply � �
Link (2-11) or (2-8) �/ � 24 V supply � �
2-5 or 2-6 control or reset contact � �
1-3-4 timed output contact � �
1
7 3 4
6 2 8
-
+
1
10 3 4
5 2 11
-
+
6
7
812
34 5
~+
U
~
Start
(1)
+~
9
U
6 78
10111
234
5
-~
Start
(1)
References :page 2/71
Dimensions :page 2/71
2/71
2
Functions,references,dimensions 2
Zelio Time - timing relays 2
Panel-mounted, plug-in, universal relays
Relay output, 1 C/O contact� Red illuminated display� Multifunction� Multi-range� Multivoltage � 1 relay output� Locking of access to programming� Upcount or downcount mode� Internal supply by lithium battery (10 years at 20 °C)
Function diagramsFunction A Function B Function C
Delay on energisation1 timed contact
Timing on impulse, one shot
Off-delay
Function D Function Di Function HFlashing relay
Flashing relay
Timing on energisation
References
Plug-in 8-pin 11-pinFunctions Multifunction Multifunction
A, B, C, D, Di, H A, B, C, D, Di, HTiming ranges 99.99 s, 999.99 s, 9999 s, 99 min 59 s, 99.99 min, 999.9 min, 9999 min, 99 h 59 min, 99.99 h,
999.9 h, 9999 hRelay output 1 timed C/O contact 1 timed C/O contactRated current 8 A 8 A
Voltages � or � 24 V and � or � 48 V RE 88 857 604 RE 88 857 704� or � 24 V and � 110 V, 50/60 Hz
RE 88 857 607 RE 88 857 707
� or � 24 V and � 24…240 V, 50/60 Hz
RE 88 857 601 RE 88 857 701
Weight (kg) 0.100 0.100Socket (1) 8-pin RUZ 1D –
11-pin – RUZ 1AWeight (kg) 0.067 0.067
(1) These products are sold in packs of 10.
Dimensions
Panel cut-out
2-10
1-3-4
T
2-10
2-5/6
T
1-3-4
∞
2-10
2-5/6
1-3-4∞ T
2-10
1-3-4
T T T T T
2-10
1-3-4
T T T T T
2-10
1-3-4
T
5614
61
MODEVALID
9,7
74,2 16
48
48
45+ 0,6 0
45+
0,6
0
Characteristics :page 2/70
Schemes :page 2/70