• Grundfos has been selling circulators for 65 years.• There are more than 3 million Alphas and Magnas installed globally.• The warranty rate on Magna in North America has been less than 0.5%

Page 3: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

We already have Magna - Why MAGNA3?

Page 4: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

MAGNA3 offers the broadest range

14 Models11 Single head3 Twin head

Voltage variants increased115V up to 1HP

208-230V all Liquid Temperature range expanded

14F to 230FCast Iron and Stainless (single head only)

Page 5: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

The MAGNA3 saves more energy than any other circulatorHydraulic

Efficiency

10-15%

Electric Efficiency

10-20%

Logic & Control

• CP 30%• PP 55%• AA 65%• FLOWADA

PT ..

Installation & Persistence

Continuous Improvement for Actual System

Needs

Page 6: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Efficiency - “Leave no stone unturned”

Integrated Grundfos Sensor,

Diff. Press & Temperature

Optimized 3D Hydraulic Design

Permanent Magnet Rotor – Stronger

Magnets

Composite Rotor Can – reduced

magnetic losses

Compact Stator – reduces copper and resistance

losses

Insulation Shell reduces heat loss

through pump housing

Intelligent control sizes pump for

demand

Intelligent Monitoring

provides system performance

Page 7: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

A Few Comments on Curves

Page 8: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

The MAGNA3 offers the most flexibility with

Intelligent Control Modes.• Constant Curve• Constant Differential Pressure• Proportional Differential Pressure• AUTOADAPT• FLOWADAPT• Constant Temperature• Constant Differential Temperature

Page 9: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Electronically “Trim” pump performance

Page 10: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Maintain constant head across the system independent of flow in the system.

Con

stan

t Pre

ssu

re

Con

stan

t C

urv

e

Page 11: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Reduce unneeded pressure as flow decreases.

Pro

port

ion

al

Pre

ssure

Con

stan

t Pre

ssu

re

Con

stan

t C

urv

e

Page 12: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Default setpoint with more aggressive reduction in pressure at low flow

Con

stan

t Pre

ssu

reC

on

stan

t C

urv

e

AU

TO

AD

APT

Pro

port

ion

al Pre

ssu

re

Page 13: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Adapts setpoint to system

Con

stan

t Pre

ssu

reC

on

stan

t C

urv

e

AU

TO

AD

APT

Pro

port

ion

al Pre

ssu

re

Page 14: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

AUTOADAPT with user defined flow limit

User Defined Flow LimitationC

on

stan

t Pre

ssu

reC

on

stan

t C

urv

ePro

port

ion

al Pre

ssu

re

FLO

WA

DA

PT

AU

TO

AD

APT

Page 15: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Adapt setpoint to system based on flow limit

Flow Limitation

Con

stan

t Pre

ssu

reC

on

stan

t C

urv

ePro

port

ion

al Pre

ssu

re

FLO

WA

DA

PT

AU

TO

AD

APT

Page 16: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Maintain Constant Temperature in flow pipe

Con

stan

t Pre

ssu

reC

on

stan

t C

urv

ePro

port

ional Pre

ssure

Con

stan

t Te

mpera

ture

Page 17: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Maintain Constant Temperature Delta across load

Con

stan

t Pre

ssu

reC

on

stan

t C

urv

eC

onst

ant

Tem

pera

ture

Diff

ere

nti

al

Tem

pera

ture

Page 18: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

MAGNA3 is much more than a pump

• Temperature• Speed

• Flow • Power

• Head• Energy

• BTU• History

Page 19: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

MAGNA3 saves $$$ by eliminating the need for additional monitoring equipment and data point integration

Operating ModeSetpointControl ModeAlarm/WarningPower and EnergyPressure HeadFlowSpeed and FrequencyDigital Input/OuputMotor CurrentLiquid TemperatureOperating HoursTotal On TimeNumber of StartsReturn TemperatureBTUBTU/hrDifferential Temperatureand more…..

CIM Accessory delivers all of this data from the pump to the BMS System

• Bacnet• Lonworks• Modbus• Profibus

Page 20: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

MAGNA3 saves time with simple Intelligent Interface

Page 21: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Simple from the start – MAGNA3 will guide the user through startup

Page 22: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Simple to navigate menu provides quick access to status or settings

Page 23: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Intelligent monitoring provides the most information ever seen

MAGNA3 comes with a monitoring function, which makes it possible to keep track of the heat energy distribution and consumption within a system. This avoids excessive energy bills caused by system imbalances.

The heat energy meter makes installing a separate energy metering device within your system superfluous.

Page 24: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Historic log enables future system optimization

Every duty point and the operational conditions are tracked and stored in the pump.

The 3D work log and duty over time curve, provide instant overviews of historical pump performance and operational conditions.

The perfect tools for pump optimization, replacement and troubleshooting.

Page 25: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Wire to Water is what’s important

623Hydraulic Efficiency

MAGNA3 40-180

TOTAL Efficiency

EXAMPLE: B&G Stocking Model 623 (1.5x1.5x7) vs MAGNA3 40-180

50%

60%

70%

40%

30%

20%

10%

Page 26: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

MAGNA3 is optimized for variable speed efficiency

EXAMPLE: B&G Stocking Model 623 (1.5x1.5x7) vs MAGNA3 40-180

Page 27: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

EXAMPLE: B&G Stocking Model 623 (1.5x1.5x7) vs MAGNA3 40-180

Page 28: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

“Wire to Water” and EEI ( Energy Efficiency Index) will be how the game is played.

0

10

20

30

40

50

60

70

80

90

100

Typicalinstalledcirculator

EuP 2013 EuP 2015 Benchmark MAGNA3EEI 0.27

EEI 0.23

EEI 0.20

EEI 0.17MAGNA3 65-120

75% Energy Reduction

before AUTOADAPT

Page 29: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

Everyone benefits from MAGNA3•Engineers

•Contractors

•Maintenance Managers

•Owners

•You too

Page 30: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

MAGNA1 is “Lean and Mean”

Control Settings• 3 Constant Curve• 3 Constant Pressure• 3 Proportional Pressure

Interface• Grundfos Eye• LED Field• Single Button

Communication• None

Page 31: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”

A Solution for Every Job

MAGNA3Whisper QuietMaintenance FreeHighest EfficiencyAUTOADAPTFLOWADAPTMonitoringCommunicationand more…

UPSWhisper QuietMaintenance Free3-Speed

MAGNA1Whisper QuietMaintenance FreeHigh Efficiency3-Speed3-Constant Pressure3-Proportional Pressure