COMPACT I/O SELECTION GUIDE 1769 SERIES

Transcript of 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P...

Page 1: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

COMPACT I/OSELECTION GUIDE

1769 SERIES

Page 2: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

2

Publication 1769-SG002E-EN-P — January 2007

I/O for EveryApplication

Rockwell Automation is the only company that can offer you the complete automationexperience with world-class I/O products for virtually every application need. You canchoose from I/O that is distributed with the application or integrated with thecontroller. The choice is yours.

Rockwell Automation offers block I/O, modular I/O, and chassis-based I/O. This tablesummarizes our modular I/O selection. This selection guide summarizes the 1769Compact I/O offering.

I/O Family Description

1734 POINT I/O

� 1, 2, or 4 I/O per module

� Compact modular assembly

� Configure backplane size by plugging in bases/modules

� Auto Device Replace (ADR)

� Removable terminations

1794 FLEX I/O

� 4...32 I/O per module

� More than 60 products to choose from

� Easy configuration

� Compact modular assembly

� Configure backplane size by plugging in terminal bases/modules

� Connect I/O directly - no separate terminal blocks required

1797 FLEX Ex I/O

� 2...16 I/O per module

� Intrinsically Safe (IS) I/O for Class I, II, III, Div. 1 hazardous areas

� Compact modular assembly

� RIUP and advanced diagnostics

� No need for IS barriers

1798 FLEXArmor I/O

� 4 or 8 I/O per module

� Compact modular assembly

� Machine-mountable; IP67 and NEMA 4X, 6P

� Connect I/O directly with quick-disconnect connectors

1769 Compact I/O

� 2...32 I/O per module

� Compact modular assembly

� Configure backplane size by plugging in modules

� Use for local I/O with a MicroLogix 1500 controller or a CompactLogix controllermodule

Page 3: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

3

Publication 1769-SG002E-EN-P — January 2007

Compact I/OModules

What's new:

� 1769-IG16

� 1769-OG16

� 1769-OB32T

� 1769-BOOLEAN

� Once the modules are locked together, the system becomes a rugged assembly.

� Upper and lower tongue-and-groove slots guide the module during installation andsecure the module within the system.

� Removable terminal blocks help ease the wiring task.

� Self-lifting, field-wire pressure plates cut installation time.

� The patented bus connector with locking function enables reliable module andsystem communication.

� A color bar is provided on the front of the module.

� Digital and field circuits are optically isolated.

Page 4: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

4

Publication 1769-SG002E-EN-P — January 2007

The Compact I/O system offers low-cost per point, ease of acquisition, and flexibleconfiguration and mounting options, providing an ideal solution for many industries.You can use the flexible 1769 Compact I/O system with several Allen-Bradley controlsystems.

System Description

1768-L43 CompactLogix Controller

Use Compact I/O modules as the primary I/O (local ornetworked expansion) for the controller. For more information,see the CompactLogix Selection Guide, publication 1768-SG001.

1769 CompactLogix Controller

Use Compact I/O modules as the primary I/O (local ornetworked expansion) for the controller. For more information,see the CompactLogix Selection Guide, publication 1769-SG001.

1769-SDN DeviceNet Adapter Module

Use Compact I/O modules as the primary I/O for the adapter(30 modules maximum). This allows the 1769 Compact I/Osystem to be used with a DeviceNet master.

1764 MicroLogix 1500 Packaged Controller

Use Compact I/O modules as modular expansion I/O (8modules maximum) for the base I/O. You can have up to 16modules when you use the MicroLogix 1500 series C processorwith a series B base and RSLogix 500 software, version 5.0 orlater. For more information, see the MicroLogix 1500 SystemOverview, publication 1764-SO001.

Page 5: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

5

Publication 1769-SG002E-EN-P — January 2007

Specifying aCompact I/OSystem

Follow these steps as you specify your Compact I/O system.

� Step See

1 Select I/O devices

Use a spreadsheet to record the:

� location of the module.

� number of points needed.

� appropriate catalog number.

� number of points available per module.

� number of modules.

Digital I/O modules 7

Analog I/O modules 31

Specialty I/O modules 58

Communication modules 63

2 Select a 1492 wiring system

Choose a wiring system as an alternative to the terminalblock that comes with the module.

Wiring systems 31

IFMs and cables for digital modules 78

IFMs and cables for analog modules 84

3 Select a control interface

Select the appropriate controller based on the type andnumber of I/O points needed.

1768 CompactLogix controller 114

1769 CompactLogix controller 115

1764 MicroLogix 1500packaged controller 117

1769-ADN DeviceNet adapter module 119

4 Select power supplies

Install additional power supplies if power consumptionexceeds the maximum for a single power supply.

Power supply specifications 122

5 Select the mounting system

Panel or DIN-rail mount your 1769 Compact I/O system.Mounting 127

6 Select software

Determine the software products you need to configure andprogram your application based on the system design.

Available software products 130

Programming software 130

Network configuration software 134

Page 6: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

6

Publication 1769-SG002E-EN-P — January 2007

Step 1 - Select:

� I/O modules

Selecting Compact I/OModulesThe 1769 Compact I/O modules can be used with a CompactLogix controller, as wellas for expansion I/O in a MicroLogix 1500 controller assembly or in an assembly witha 1769-ADN DeviceNet adapter module. Unless connected to a MicroLogix 1500 base,each bank of I/O modules must include its own power supply.

Install the I/O modules on a panel with two mounting screws or on a DIN rail. Themodules mechanically lock together by means of a tongue-and-groove design andhave an integrated communication bus that is connected from module to module by amoveable bus connector.

Each I/O module includes a built-in removable terminal block with finger-safe coverfor connections to I/O sensors and actuators. The terminal block is behind a door atthe front of the module. I/O wiring can be routed from beneath the module to the I/Oterminals.

About Power SupplyDistance Ratings

Check each module’s specification table for the power supply distance rating. Thisindicates how many slot positions the module can be from the power supply.

Topic Page

Digital I/O modules 7Analog I/O modules 31Specialty I/O modules 58Communication modules 63

Page 7: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

7

Publication 1769-SG002E-EN-P — January 2007

Digital I/O Modules Choose digital I/O modules when you need these features.

Most output modules have built-in surge suppression to reduce the effects of high-voltage transients. Use an additional suppression device if an output is being used tocontrol inductive devices, such as relays, motor starters, solenoids, or motors.Additional suppression is especially important if your inductive device is in series withor parallel to hard contacts, such as pushbuttons or selector switches.

Add a suppression device directly across the coil of an inductive device to reduce theeffects of voltage transients caused by interrupting the current to that device and toprolong the life of the switch contacts.

Type of Module Description

Input

An input module responds to an input signal in the followingmanner:

� Input filtering limits the effect of voltage transients caused bycontact bounce and/or electrical noise. If not filtered, voltagetransients could produce false data. All input modules use inputfiltering.

� Optical isolation shields logic circuits from possible damage dueto electrical transients.

� Logic circuits process the signal.

� An input LED indicator turns on or off indicating the status of thecorresponding input device.

Output

An output module controls the output signal in the followingmanner:

� Logic circuits determine the output status.

� An output LED indicator displays the status of the output signal.

� Optical isolation separates module logic and bus circuits fromfield power.

� The output driver turns the corresponding output on or off.

Page 8: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

8

Publication 1769-SG002E-EN-P — January 2007

Selecting Digital I/O Modules

Voltage Category Catalog Number Input/Output Page

ac100/120V ac 1769-IA8I 8 inputs, individually isolated 9100/120V ac 1769-IA16 16 inputs 10200/240V ac 1769-IM12 12 inputs 11100...240V ac 1769-OA8 8 outputs 12120...240V ac 1769-OA16 16 outputs 13dc5V dc TTL input 1769-IG16 16 inputs 14

24V dc sinking/sourcing

1769-IQ16 16 inputs 151769-IQ16F 16 inputs, high-speed 161769-IQ32 32 inputs 171769-IQ32T 32 inputs 18

24V dc sinking/sourcing input

ac/dc normally open relayoutput

1769-IQ6XOW46 inputs

4 outputs19

24V dc sourcing1769-OB8 8 outputs 201769-OB16 16 outputs 211769-OB16P 16 outputs, protected 22

5V dc TTL output 1769-OG16 16 outputs 23

24V dc sourcing1769-OB32 32 outputs 241769-OB32T 32 outputs 25

24V dc sinking1769-OV16 16 outputs 261769-OV32T 32 outputs 27

ac/dc

normally open relay1769-OW8 8 outputs 291769-OW8I 8 outputs, individually isolated 301769-OW16 16 outputs 31

Certifications: C-UL (under CSA C22.2 No. 142), UL 508, CE

Page 9: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

9

Publication 1769-SG002E-EN-P — January 2007

1769 CompactDigital ac InputModules

These are the digital ac input modules.

1769-IA8I Isolated 120V ac Input Module

Attribute ValueVoltage Category/Type, Input 100 or 120V AC

Voltage, On-State Input, Min. 79V ac

Voltage, On-State Input, Max. 132V ac

Operating Frequency Range 47…63 Hz

Number of Inputs 8

Backplane Current (mA) at 5V 90 mA✶

Voltage, Off-State Input, Max. 20V ac

Current, Off-State Input, Max. 2.5 mA

Voltage, On-State Input, Min. 79V ac

Current, On-State Input, Min. 5 mA @ 79V ac

Inrush Current, Max. 250 mA�

Input Impedance, Nom.12 kΩ @ 50 Hz10 kΩ @ 60 Hz

IEC Input Compatibility Type 1+

Power Supply Distance Rating 8 modules

Isolated Groups 8 individually isolated inputs

✶190 mA max.�A current limiting resistor can be used to limit inrush current; however, the operating characteristics of the ac input circuit will

be affected. If a 6.8 kΩ (2.5 W minimum) resistor is placed in series with the input, the inrush current is reduced to 35 mA. Inthis configuration the minimum on-state voltage increases to 92V ac. Before adding the resistor in a hazardous environment,be sure to consider the operating temperature of the resistor and the temperature limits of the environment. The operatingtemperature of the resistor must remain below the temperature limit of the environment.

Page 10: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

10

Publication 1769-SG002E-EN-P — January 2007

1769-IA16 120V acInput Module

Attribute ValueVoltage Category/Type, Input 100 or 120V AC

Voltage, On-State Input, Min. 132V ac

Voltage, On-State Input, Max. 132V ac

Operating Frequency Range 47…63 Hz

Number of Inputs 16

Backplane Current (mA) at 5V 115 mA

Voltage, Off-State Input, Max. 20V ac

Current, Off-State Input, Max. 2.5 mA

Voltage, On-State Input, Min. 79V ac

Current, On-State Input, Min. 5 mA @ 79V ac

Inrush Current, Max. 250 mA✶

Input Impedance, Nom.12 kΩ @ 50 Hz10 kΩ @ 60 Hz

IEC Input Compatibility Type 1+

Power Supply Distance Rating 8 modules

Isolated Groups Group 1: outputs 0 to 15 (internally connected to common)

✶A current limiting resistor can be used to limit inrush current; however, the operating characteristics of the ac input circuit willbe affected. If a 6.8 kΩ (2.5 W minimum) resistor is placed in series with the input, the inrush current is reduced to 35 mA. Inthis configuration the minimum on-state voltage increases to 92V ac. Before adding the resistor in a hazardous environment,be sure to consider the operating temperature of the resistor and the temperature limits of the environment. The operatingtemperature of the resistor must remain below the temperature limit of the environment.

Page 11: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

11

Publication 1769-SG002E-EN-P — January 2007

1769-IM12 240V acInput Module

Attribute ValueVoltage Category/Type, Input 200 or 240V AC

Voltage, On-State Input, Min. 159V ac

Voltage, On-State Input, Max. 265V ac

Operating Frequency Range 47…60 Hz

Number of Inputs 12

Backplane Current (mA) at 5V 100 mA

Voltage, Off-State Input, Max. 40V ac

Current, Off-State Input, Max. 2.5 mA

Voltage, On-State Input, Min. 159V ac

Current, On-State Input, Min. 5 mA @ 159V ac

Inrush Current, Max. 250 mA✶

Input Impedance, Nom.27 kΩ @ 50 Hz23 kΩ @ 60 Hz

IEC Input Compatibility Type 1+

Power Supply Distance Rating 8 modules

Isolated Groups Group 1: inputs 0 to 11 (internally connected commons)

✶A current limiting resistor can be used to limit inrush current; however, the operating characteristics of the ac input circuit willbe affected. If a 15 kΩ (1.5W minimum) resistor is placed in series with the input, the inrush current is reduced to 35 mA. Inthis configuration the minimum on-state voltage increases to 176V ac. Before adding the resistor in a hazardous environment,be sure to consider the operating temperature of the resistor and the temperature limits of the environment. The operatingtemperature of the resistor must remain below the temperature limit of the environment.

Page 12: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

12

Publication 1769-SG002E-EN-P — January 2007

1769 CompactDigital ac OutputModules

These are the digital ac output modules.

1769-OA8 120/240V ac Output Module

Attribute ValueVoltage Category/Type, Output 100…240V AC

Voltage, On-State Output, Min. 85V ac

Voltage, On-State Output, Max. 265V ac

Operating Frequency Range 47…63 Hz

Number of Outputs 8

Backplane Current (mA) at 5V 145 mA

Leakage Current, Off-State Output, Max2.0 mA at 132V ac2.5 mA at 265V ac✶

Current, On-State Output, Min. 10.0 mA

Voltage Drop, On-State Output, Max. 1.5V ac at 0.5 A

Output Surge Current, Max. 10.0 A✶�

Power Supply Distance Rating 8 modules

Isolated GroupsGroup 1: outputs 0 to 3Group 2: outputs 4 to 7

✶Recommended Loading Resistor - To limit the effects of leakage current through solid state outputs, a loading resistor canbe connected in parallel with your load. For 120V ac operation, use a 15 kΩ, 2W resistor. For 240V ac operation use a 15kΩ, 5W resistor.�Repeatability is once every 2 seconds for a duration of 25 ms.Surge Suppression - Connecting surge suppressors across your external load will extend the life of the Triac outputs. For

additional details, refer to Industrial Automation Wiring and Grounding Guidelines, Allen-Bradley publication 1770-4.1.

Page 13: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

13

Publication 1769-SG002E-EN-P — January 2007

1769-OA16 120/240V ac Output Module✶

Attribute ValueVoltage Category/Type, Output 100…240V AC

Voltage, On-State Output, Min. 85V ac

Voltage, On-State Output, Max. 265V ac

Operating Frequency Range 47…63 Hz

Number of Outputs 16

Backplane Current (mA) at 5V 225 mA

Leakage Current, Off-State Output, Max2.0 mA at 132V ac2.5 mA at 265V ac✶

Current, On-State Output, Min. 10.0 mA

Voltage Drop, On-State Output, Max. 1.5V ac at 0.5A

Output Surge Current, Max. 10.0 A�‡

Power Supply Distance Rating 8 modules

Isolated GroupsGroup 1: outputs 0 to 7Group 2: outputs 8 to 15

✶Recommended Loading Resistor - To limit the effects of leakage current through solid state outputs, a loading resistor canbe connected in parallel with your load. For 120V ac operation, use a 15 kΩ, 2W resistor. For 240V ac operation use a 15kΩ, 5W resistor.�Repeatability is once every 2 seconds for a duration of 25 ms.‡Surge Suppression - Connecting surge suppressors across your external load will extend the life of the Triac outputs. For

additional details, refer to "Industrial Automation Wiring and Grounding Guidelines," Allen-Bradley publication 1770-4.1.

✶The 1769-OA16 module is a 1.5-slot wide module.

Page 14: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

14

Publication 1769-SG002E-EN-P — January 2007

1769 CompactDigital dc InputModules

These are the digital dc input modules.

1769-IG16 TTL Input Module

Attribute ValueVoltage Category 5V dc TTL signal input

Operating Voltage Range4.5…5.5V dc50 mV peak-to-peak ripple, max

Number of Inputs 16

Backplane Current (mA) at 5V 120 mA

Heat Dissipation1.6 Total Watts (The W per point, plus the min W, with all pointsenergized.)

Digital FilterOff to on: 0 s, 100 μs, 500 μs, 1 ms, 2 ms, 4 ms, 8 msOn to off: 0 s, 100 μs, 500 μs, 1 ms, 2 ms, 4 ms, 8 ms

Voltage, Off-State Input (typical) 2.0…5.5V dc✶

Current, Off-State Input, Max. 4.1 mA

Voltage, On-State Input (typical) -0.2…0.8V dc✶

Input Current 3.7 mA @ 5V dc

Power Supply Distance Rating 8 modules

Input Point to Bus (CompactBus) IsolationVerified by one of the following dielectric tests: 1200V ac for 2 sor 1697V dc for 2 s75V dc working voltage (IEC Class 2 reinforced insulation)

✶TTL inputs are inverted (0.2…0.8V dc = logic low voltage = on; 2.0…5.5V dc = logic high voltage = off). Use a NOTinstruction in the ladder program to convert to traditional true=high logic.

Page 15: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

15

Publication 1769-SG002E-EN-P — January 2007

1769-IQ16 Current Sinking/Sourcing 24V dc InputModule

Attribute ValueVoltage Category/Type, Input 24V DC, sinking or sourcing

Voltage, On-State Input, Min. 10V dc

Voltage, On-State Input, Max.30V dc @ 30 °C (86 °F)26.4V dc @ 60 °C (140 °F)

Number of Inputs 16

Backplane Current (mA) at 5V 115 mA

Input Delay Time, ON to OFF 8 ms

Input Delay Time, OFF to ON 8 ms

Voltage, Off-State Input, Max. 5V dc

Current, Off-State Input, Max. 1.5 mA

Voltage, On-State Input, Min. 10V dc

Current, On-State Input, Min. 2 mA

Inrush Current, Max. 250 mA

Input Impedance, Nom. 3 kΩ

IEC Input Compatibility Type 1+

Power Supply Distance Rating 8 modules✶

Isolated GroupsGroup 1: inputs 0 to 7Group 2: inputs 8 to 15

✶The module may not be more than 8 modules away from the power supply or controller.

Page 16: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

16

Publication 1769-SG002E-EN-P — January 2007

1769-IQ16F High-speed, CurrentSinking/Sourcing 24V dc Input Module

Attribute ValueVoltage Category/Type, Input 24V DC, sinking or sourcing

Voltage, On-State Input, Min. 10V dc

Voltage, On-State Input, Max.30V dc @ 30 °C (86 °F)26.4V dc @ 60 °C (140 °F)

Number of Inputs 16

Backplane Current (mA) at 5V 110 mA

Input Delay Time, ON to OFF 300 μs

Input Delay Time, OFF to ON 1 ms

Voltage, Off-State Input, Max. 5V dc

Current, Off-State Input, Max. 1.5 mA

Voltage, On-State Input, Min. 10V dc

Current, On-State Input, Min. 2 mA

Inrush Current, Max. 250 mA

Input Impedance, Nom. 3 kΩ

IEC Input Compatibility Type 1+

Power Supply Distance Rating 8 modules✶

Isolated GroupsGroup 1: inputs 0 to 7Group 2: inputs 8 to 15

✶The module may not be more than 8 modules away from the power supply or controller.

Page 17: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

17

Publication 1769-SG002E-EN-P — January 2007

1769-IQ32 Current Sinking/Sourcing 24V dc InputModule✶

Attribute ValueVoltage Category/Type, Input 24V DC, sinking or sourcing

Voltage, On-State Input, Min. 10V dc

Voltage, On-State Input, Max.30V dc @ 30 °C (86 °F)26.4V dc @ 60 °C (140 °F)

Number of Inputs 32

Backplane Current (mA) at 5V 170 mA

Input Delay Time, ON to OFF 8 ms

Input Delay Time, OFF to ON 8 ms

Voltage, Off-State Input, Max. 5V dc

Current, Off-State Input, Max. 1.5 mA

Voltage, On-State Input, Min. 10V dc

Current, On-State Input, Min. 2 mA

Inrush Current, Max. 250 mA

Input Impedance, Nom.5.2 kΩ @ 24V dc6.1 kΩ @ 30V dc

IEC Input Compatibility Type 1+

Power Supply Distance Rating 8 modules✶

Isolated Groups

Group 1: inputs 0 to 7Group 2: inputs 8 to 15Group 3: inputs 16 to 23Group 4: inputs 24 to 31�

✶The module may not be more than 8 modules away from the power supply or controller.�Isolated groups operate in either sink or source configurations.

✶The 1769-IQ32 module is a 1.5-slot wide module.

Page 18: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

18

Publication 1769-SG002E-EN-P — January 2007

1769-IQ32T Current Sinking/Sourcing 24V dcInput Module

Attribute ValueVoltage Category/Type, Input 24V dc, sinking or sourcing

Operating Voltage Range 20.4…26.4V dc

Number of Inputs 32

Backplane Current (mA) at 5V 170 mA

Input Delay Time, ON to OFF 8 ms✶

Input Delay Time, OFF to ON 8 ms✶

Voltage, Off-State Input, Max. 11V dc

Current, Off-State Input, Max. 1.7 mA

Voltage, On-State Input, Min. 19V dc

Current, On-State Input, Min. 3 mA

Inrush Current, Max. 5 mA

Input Impedance, Nom. 5.6 KΩ

Power Supply Distance Rating 8 modules

Isolated Groups

Group 1: inputs 0 to 7Group 2: inputs 8 to 15Group 3: inputs 16 to 23Group 4: inputs 24 to 31

✶Preliminary.

Page 19: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

19

Publication 1769-SG002E-EN-P — January 2007

1769-IQ6XOW4 Combination Input/OutputModule

Attribute ValueVoltage Category/Type, Input 24V dc, sinking or sourcing

Voltage, On-State Input, Min. 10V dc

Voltage, On-State Input, Max.30V dc @ 30 °C (86 °F)26.4V dc @ 60 °C (140 °F)

Number of Inputs 6

Number of Outputs 4

Backplane Current (mA) at 5V 105 mA

Backplane Current (mA) at 24V 50 mA

Voltage, Off-State Input, Max. 5V dc

Current, Off-State Input, Max. 1.5 mA

Voltage, On-State Input, Min. 10V dc

Current, On-State Input, Min. 2 mA

Inrush Current, Max. 250 mA

Input Impedance, Nom. 3 kΩ

IEC Input Compatibility Type 3

Output Delay Time, ON to OFF, Max. 10 ms

Output Delay Time, OFF to ON, Max. 10 ms

Power Supply Distance Rating 8 modules

Isolated GroupsGroup 1: inputs 0…5Group 2: outputs 0…3

Page 20: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

20

Publication 1769-SG002E-EN-P — January 2007

1769 CompactDigital dc OutputModules

These are the digital dc output modules.

1769-OB8 Current Sourcing 24V dc OutputModule

Attribute ValueVoltage Category/Type, Output 24V dc, sourcing

Voltage, On-State Output, Min. 20.4V dc

Voltage, On-State Output, Max. 26.4V dc

Number of Outputs 8

Backplane Current (mA) at 5V 145 mA

Output Delay Time, OFF to ON 0.1 ms

Output Delay Time, ON to OFF 1.0 ms

Leakage Current, Off-State Output, Max 1.0 mA @ 26.4V ac

Current, On-State Output, Min. 1.0 mA

Voltage Drop, On-State Output, Max. 1.0V dc @ 2 A

Output Surge Current, Max. 4.0 A

Power Supply Distance Rating 8 modules✶

Isolated GroupsGroup 1: outputs 0 to 3Group 2: outputs 4 to 7

✶The module may not be more than this number of modules away from the power supply.

Page 21: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

21

Publication 1769-SG002E-EN-P — January 2007

1769-OB16 Current Sourcing 24V dc OutputModule

Attribute ValueVoltage Category/Type, Output 24V dc, sourcing

Voltage, On-State Output, Min. 20.4V dc

Voltage, On-State Output, Max. 26.4V dc

Number of Outputs 16

Backplane Current (mA) at 5V 200 mA

Output Delay Time, OFF to ON 0.1 ms

Output Delay Time, ON to OFF 1.0 ms

Leakage Current, Off-State Output, Max 1.0 mA @ 26.4V ac✶

Current, On-State Output, Min. 1.0 mA

Voltage Drop, On-State Output, Max. 1.0V ac @ 1.0 A

Output Surge Current, Max. 2.0 A�‡

Power Supply Distance Rating 8 modules§

Isolated Groups Group 1: outputs 0 to 15 (internally connected to common)

✶Typical Loading Resistor - To limit the effects of leakage current through solid state outputs, a loading resistor can beconnected in parallel with your load. Use a 5.6 kΩ, 0.5 W resistor for transistor outputs, 24V dc operation.�Repeatability is once every 2 seconds for a duration of 10 ms.‡Recommended Surge Suppression - Use a 1N4004 diode reverse-wired across the load for transistor outputs switching 24V

dc inductive loads. For additional details, refer to "Industrial Automation Wiring and Grounding Guidelines," Allen-Bradleypublication 1770-4.1

§The module may not be more than this number of modules away from the power supply.

Page 22: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

22

Publication 1769-SG002E-EN-P — January 2007

1769-OB16P Protected Current Sourcing 24V dcOutput Module

Attribute ValueVoltage Category/Type, Output 24V dc, sourcing

Voltage, On-State Output, Min. 20.4V dc

Voltage, On-State Output, Max. 26.4V dc

Number of Outputs 16

Backplane Current (mA) at 5V 160 mA✶

Output Delay Time, OFF to ON 1.0 ms

Output Delay Time, ON to OFF 2.0 ms

Leakage Current, Off-State Output, Max 1.0 mA @ 26.4V ac�

Current, On-State Output, Min. 1.0 mA

Voltage Drop, On-State Output, Max. 0.5V dc

Output Surge Current, Max. 2.0 A‡§

Power Supply Distance Rating 8 modules♣

Isolated Groups Group 1: outputs 0 to 15 (internally connected to common)

✶200 mA max.�Typical Loading Resistor - To limit the effects of leakage current through solid state outputs, a loading resistor can be

connected in parallel with your load. Use a 5.6 kΩ, 0.5 W resistor for transistor outputs, 24V dc operation.‡Repeatability is once every 2 seconds for a duration of 10 ms.§Recommended Surge Suppression - Use a 1N4004 diode reverse-wired across the load for transistor outputs switching 24V

dc inductive loads. For additional details, refer to "Industrial Automation Wiring and Grounding Guidelines," Allen-Bradleypublication 1770-4.1.

♣The module may not be more than this number of modules away from the power supply.

Page 23: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

23

Publication 1769-SG002E-EN-P — January 2007

1769-OG16 TTL Output Module

Attribute ValueVoltage Category 5V dc TTL signal output

Operating Voltage Range4.5…5.5V dc50 mV peak-to-peak ripple, max

Number of Outputs 16

Backplane Current (mA) at 5V 200 mA

Heat Dissipation1.2 Total Watts (The W per point plus the min W, with all pointsenergized.)

Signal On Delay, Max (resistive load) 0.25

Signal Off Delay, Max (resistive load) 0.50

Voltage, Off-State Input (typical) 4.5…5.5V dc✶

Voltage, On-State Output, Max. 0…0.4V dc

Current, On-State Output, Min. 0.15 mA

Output Continuous Current per Point, Max. 24 mA

Power Supply Distance Rating 8 modules

Output Point to Bus (CompactBus) IsolationVerified by one of the following dielectric tests: 1200V ac for 2 sor 1697V dc for 2 s75V dc working voltage (IEC Class 2 reinforced insulation)

✶TTL outputs are inverted (on = 1 = logic low voltage = 0…0.4V dc; off = 0 = logic high voltage = 4.5…5.5V dc). Use a NOTinstruction in the ladder program to convert to traditional true=high logic.

Page 24: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

24

Publication 1769-SG002E-EN-P — January 2007

1769-OB32 Current Sourcing 24V dc OutputModule✶

Attribute ValueVoltage Category/Type, Output 24V dc, sourcing✶

Voltage, On-State Output, Min. 20.4V dc

Voltage, On-State Output, Max. 26.4V dc

Number of Outputs 32

Backplane Current (mA) at 5V 300 mA

Output Delay Time, OFF to ON 0.1 ms

Output Delay Time, ON to OFF 1.0 ms

Leakage Current, Off-State Output, Max 1.0 mA @ 26.4V ac�

Current, On-State Output, Min. 1.0 mA

Voltage Drop, On-State Output, Max. 1.0V dc @ 1.0 A

Output Surge Current, Max. 2.0 A (Repeatable once every 2 s for a duration of 10 ms.)‡

Power Supply Distance Rating 6 modules§

Isolated GroupsGroup 1: outputs 0 to 15 (internally connected to DC COM 1)Group 2: outputs 16 to 31 (internally connected to DC COM 2)

✶Sourcing Output - Source describes the current flow between the I/O module and the field device. Sourcing output circuitssupply (source) current to sinking field devices. Field devices connected to the negative side (DC Common) of the field powersupply are sinking field devices. Field devices connected to the positive side (+V) of the field supply are sourcing field devices.Europe: DC sinking input and sourcing output module circuits are the commonly used options.�Typical Loading Resistor - To limit the effects of leakage current through solid state outputs, a loading resistor can be

connected in parallel with your load. Use a 5.6K ohm, ½ watt resistor for transistor outputs, 24V dc operation.‡Recommended Surge Suppression - Use a 1N4004 diode reverse-wired across the load for transistor outputs switching 24V

dc inductive loads. For additional details, refer to Industrial Automation Wiring and Grounding Guidelines, Allen-Bradleypublication 1770-4.1.

§The module may not be more than this number of modules away from the power supply.

✶The 1769-OB32 module is a 1.5-slot wide module.

Page 25: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

25

Publication 1769-SG002E-EN-P — January 2007

1769-OB32T Current Solid-state Sourcing 24V dcOutput Module

Attribute ValueVoltage Category/Type, Output 24V dc, sourcing

Operating Voltage Range 10.2V dc…26.4V dc

Number of Outputs 32

Backplane Current (mA) at 5V 220 mA (1.10 W) mA

Heat Dissipation4.76 Total W (The W per point, plus the min W, with all pointsenergized.)

Signal On Delay, Max (resistive load) 0.5

Signal Off Delay, Max (resistive load) 4.0

Leakage Current, Off-State Output, Max 0.1 mA @ 26.4V dc

Continuous Current, Max0.5 A per point2.0 A per common4.0 A per module

Voltage Drop, On-State Output, Max. 0.3V dc @ 0.5 A

Output Surge Current, Max. 2.0 A (repeatability is once every 2 s for a duration of 10 ms)

Power Supply Distance Rating 8 modules

Output Point to Bus IsolationVerified by one of the following dielectric tests: 1200V ac for 2 sor 1697V dc for 2 s75V dc working voltage (IEC Class 2 reinforced insulation)

Isolated GroupsGroup 1: outputs 0…15 (internally connected to DC COM 1)Group 2: outputs 16…31 (internally connected to DC COM 2)

Page 26: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

26

Publication 1769-SG002E-EN-P — January 2007

1769-OV16 Current Sinking 24V dc OutputModule

Attribute ValueVoltage Category/Type, Output 24V DC, sinking

Voltage, On-State Output, Min. 20.4V dc

Voltage, On-State Output, Max. 26.4V dc

Number of Outputs 16

Backplane Current (mA) at 5V 200 mA

Output Delay Time, OFF to ON 0.1 ms

Output Delay Time, ON to OFF 1.0 ms

Leakage Current, Off-State Output, Max 1.0 mA @ 26.4V ac✶

Current, On-State Output, Min. 1.0 mA

Voltage Drop, On-State Output, Max. 1.0V ac @ 1.0 A

Output Surge Current, Max. 2.0 A�‡

Power Supply Distance Rating 8 modules§

Isolated Groups Group 1: outputs 0 to 15 (internally connected to common)

✶Typical Loading Resistor - To limit the effects of leakage current through solid state outputs, a loading resistor can beconnected in parallel with your load. Use a 5.6 kΩ, o.5 W resistor for transistor outputs, 24V dc operation.�Repeatability is once every 2 seconds for a duration of 10 ms.‡Recommended Surge Suppression - Use a 1N4004 diode reverse-wired across the load for transistor outputs switching 24V

dc inductive loads. For additional details, refer to "Industrial Automation Wiring and Grounding Guidelines," Allen-Bradleypublication 1770-4.1.

§The module may not be more than this number of modules away from the power supply.

Page 27: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

27

Publication 1769-SG002E-EN-P — January 2007

1769-OV32T Current Sinking 24V dc OutputModule

Attribute ValueVoltage Category/Type, Output 24V DC, sinking

Operating Voltage Range 10.2…26.4V dc

Number of Outputs 32

Backplane Current (mA) at 5V 220 mA

Output Delay Time, OFF to ON 0.5 ms

Output Delay Time, ON to OFF 4.0 ms

Leakage Current, Off-State Output, Max 0.1 mA @ 26.4V ac

Current, On-State Output, Min. 1.0 mA

Voltage Drop, On-State Output, Max. 1.0V dc @ 1 A

Output Surge Current, Max. 1.0 A✶

Power Supply Distance Rating 8 modules

Isolated GroupsGroup 1: outputs 0…15 (internally connected to DC COM 1)Group 2: outputs 16…31 (internally connected to DC COM 2)

✶Preliminary.

Page 28: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

28

Publication 1769-SG002E-EN-P — January 2007

1769 CompactDigital ContactOutput Modules

These ratings apply to the digital contact output modules.

Volts, Max.

ContinuousAmps perPoint

Amperes Voltamperes

IEC 947NEMA ICS2-125Make Break Make Break

240V ac2.5 A

7.5 A 0.75 A1800 VA 180 VA AC15✶ C300

120V ac 15 A 1.5 A125V dc 1.0 A 0.22 A 28 VA DC13✶ R15024V dc 2.0 A 1.2 A 28 VA ⎯ ⎯

✶Does not apply to the 1769-OW16 module.

1769-OW8 ac/dc Relay Output Module

Attribute ValueVoltage Category/Type, Output AC/DC Relay

Voltage, On-State Output, Min. 5V ac/5V dc

Voltage, On-State Output, Max. 265V ac/125V dc

Number of Outputs 8

Backplane Current (mA) at 5V 125 mA

Backplane Current (mA) at 24V 100 mA

Output Delay Time, OFF to ON 10 ms

Output Delay Time, ON to OFF 10 ms

Leakage Current, Off-State Output, Max 0 mA

Current, On-State Output, Min. 10 mA at 5V dc

Power Supply Distance Rating 8 modules

Isolated GroupsGroup 1: outputs 0 to 3Group 2: outputs 4 to 7

Page 29: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

29

Publication 1769-SG002E-EN-P — January 2007

1769-OW8I Isolated ac/dc Relay Output Module

Attribute ValueVoltage Category/Type, Output AC/DC Relay

Voltage, On-State Output, Min. 5V ac/5V dc

Voltage, On-State Output, Max. 265V ac/125V dc

Number of Outputs 8

Backplane Current (mA) at 5V 125 mA

Backplane Current (mA) at 24V 100 mA

Output Delay Time, OFF to ON 10 ms

Output Delay Time, ON to OFF 10 ms

Leakage Current, Off-State Output, Max 0 mA

Current, On-State Output, Min. 10 mA at 5V dc

Power Supply Distance Rating 8 modules

Isolated GroupsGroup 1: outputs 0 to 3Group 2: outputs 4 to 7

Page 30: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

30

Publication 1769-SG002E-EN-P — January 2007

Attribute ValueVoltage Category/Type, Output AC/DC Relay

Voltage, On-State Output, Min. 5V ac/5V dc

Voltage, On-State Output, Max. 265V ac/125V dc

Number of Outputs 16

Backplane Current (mA) at 5V 205 mA

Backplane Current (mA) at 24V 180 mA

Output Delay Time, ON to OFF, Max. 10 ms (resistive load)

Output Delay Time, OFF to ON, Max. 10 ms (resistive load)

Leakage Current, Off-State Output, Max 0 mA

Current, On-State Output, Min. 10 mA @ 5V dc

Power Supply Distance Rating 8 modules

Isolated GroupsGroup 1: outputs 0…7Group 2: outputs 8…15

1769-OW16 ac/dc Relay Output Module✶

✶The 1769-OW16 module is a 1.5-slot wide module.

Page 31: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

31

Publication 1769-SG002E-EN-P — January 2007

Analog I/O Modules Choose analog, thermocouple, or RTD modules when you need these features:

� Individually configurable channels

� Ability to individually enable and disable channels

� On-board scaling

� Autocalibration of inputs

� Online configuration

� Selectable input filters

� Over-range and under-range detection and indication

� Selectable response to a broken input sensor

� Selectable power source

� Input modules offer both single-ended or differential inputs

� Ability to direct output device operation during an abnormal condition

� High accuracy ratings

Selecting Analog Modules

Cat. No.Number of InputsNumber of Outputs Description Page

1769-IF4 4 inputs Analog input 321769-IF4I 4 inputs Isolated analog input 341769-IF8 8 inputs Analog input 361769-OF2 2 outputs Analog output 381769-OF4CI 4 outputs, current Isolated analog output 391769-OF8C 8 outputs, current Analog output 401769-OF4VI 4 outputs, voltage Isolated analog output 411769-OF8V 8 outputs, voltage Analog output 42

1769-IF4XOF2

4 inputs

2 outputs

Analog combination inputand output

43

1769-IT6 6 inputs Thermocouple input 461769-IR6 6 inputs RTD input 50Certifications: C-UL (under CSA C22.2 No. 142), UL 508, CE, C-Tick

Page 32: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

32

Publication 1769-SG002E-EN-P — January 2007

1769-IF4 Analog Input Module

Wiring Differential Inputs

Wiring Single-ended Sensor/Transmitter Inputs

Wiring Mixed Transmitter Inputs

Page 33: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

33

Publication 1769-SG002E-EN-P — January 2007

1769-IF4 Specifications

The external power supply must be rated Class 2, with a 24V dc range of 20.4…26.4Vdc and 60 mA minimum.

Series B and later modules provide this option.

Attribute Value

Voltage Category/Type, Input

±10V dc (±10.5V dc full scale)0…10V dc (-0.5…10.5V dc full scale)0…5V dc (-0.5…5.25V dc full scale)1…5V dc (0.5…5.25V full scale)

Current Range, Analog Input 0…21 mA or 3.2…21 mA, full-scale✶

Number of Inputs 4

Backplane Current (mA) at 5V 105 mA

Backplane Current (mA) at 24V 60 mA�

Input Resolution 14 bits (unipolar)‡

Normal Mode Rejection Ratio -50 dB at 50 and 60 Hz with the 50 or 60 Hz filter selected, respectively.

Input ImpedanceCurrent Input: 250 ΩVoltage Input: 220 Ω

Accuracy Drift w/Temp.Current Input: ±0.0045%/°CVoltage Input: ±0.003%/°C

Non-linearity, Input ±0.03% full scale

Input Repeatability ±0.03%§

Module Error over Full Temperature Range±0.03% - Voltage±0.05% - Current

Input Channel ConfigurationConfiguration via configuration software screen or the user program (by writing aunique bit pattern into the module’s configuration file). Refer to your controller’s usermanual to determine if user program configuration is supported.

CalibrationThe module performs autocalibration on channel enable and on a configuration changebetween channels.

Diagnostics Type Over- or under-range by bit reporting

Power Supply Distance Rating 8 modules♣

Isolation Voltage500V ac or 710V dc for 1 minute, 30Vac/30Vdc working voltage (IEC Class 2 reinforcedinsulation), input group to bus

✶The over- or under-range flag will come on when the normal operating range (over/under) is exceeded. The module willcontinue to convert the analog input up to the maximum full scale range. The flag automatically resets when within the normaloperating range.�If the optional 24V dc Class 2 power supply is used, the 24V dc current draw from the bus is 0 mA.‡Resolution is dependent upon your filter selection. The maximum resolution is achieved with either the 50 or 60 Hz filter

selected. For resolution with other filter selections, refer to the user manual, publication 1769-UM002.§Repeatability is the ability of the input module to register the same reading in successive measurements for the same input

signal.♣The module may not be more than 8 modules away from the system power supply.

Page 34: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

34

Publication 1769-SG002E-EN-P — January 2007

1769-IF4I Isolated Analog Input Module

Wiring Differential Inputs

Wiring Single-ended Sensor/Transmitter Inputs

Page 35: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

35

Publication 1769-SG002E-EN-P — January 2007

Wiring Mixed Transmitter Inputs

1769-IF4I Specifications

Attribute Value

Voltage Category/Type, Input

±10V dc (±10.5V dc full scale)0…10V dc (-0.5…10.5V dc full scale)0…5V dc (-0.5…5.25V dc full scale)1…5V dc (0.5…5.25V full scale)

Current Range, Analog Input 0…21 mA or 3.2…21 mA, full-scale✶

Number of Inputs 4

Backplane Current (mA) at 5V 145 mA

Backplane Current (mA) at 24V 125 mA

Input Resolution 16 bits (unipolar)

Normal Mode Rejection Ratio -50 dB at 50 and 60 Hz with the 10 Hz filter selected, respectively.

Input ImpedanceCurrent Input: 249 ΩVoltage Input: 1M Ω

Accuracy Drift w/Temp.Current Input: ±0.0045%/°CVoltage Input: ±0.003%/°C

Non-linearity, Input ±0.03% full scale

Input Repeatability ±0.03%‡

Module Error over Full Temperature Range±0.03% - Voltage±0.05% - Current

Input Channel ConfigurationConfiguration via configuration software screen or the user program (by writing aunique bit pattern into the module’s configuration file). Refer to your controller’s usermanual to determine if user program configuration is supported.

Calibration The module performs only initial factory calibration.

Diagnostics Type Over- or under-range by bit reporting, process alarms

Power Supply Distance Rating 8 modules§

Isolation Voltage500V ac or 710V dc for 1 minute, 30Vac/30Vdc working voltage (IEC Class 2 reinforcedinsulation), input group to bus

✶The over- or under-range flag will come on when the normal operating range (over/under) is exceeded. The module willcontinue to convert the analog input up to the maximum full scale range. The flag automatically resets when within the normaloperating range.�Resolution is dependent upon your filter selection. The maximum resolution is achieved with either the 50 or 60 Hz filter

selected. For resolution with other filter selections, refer to the user manual, publication 1769-UM002.‡Repeatability is the ability of the input module to register the same reading in successive measurements for the same input

signal.§The module may not be more than 8 modules away from the system power supply.

Page 36: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

36

Publication 1769-SG002E-EN-P — January 2007

Wiring Differential Inputs

Wiring Single-ended Sensor/Transmitter Inputs

1769-IF8 Analog Input Module✶

✶The 1769-IF8 module is a 1.5-slot wide module.

Page 37: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

Attribute Value

Voltage Category/Type, Input

±10V dc (±10.5V dc full scale)0…10V dc (-0.5…10.5V dc full scale)0…5V dc (-0.5…5.25V dc full scale)1…5V dc (0.5…5.25V full scale)✶

Current Range, Analog Input 0…20 mA or 4…20 mA, full-scale�

Number of Inputs 8

Backplane Current (mA) at 5V 120 mA

Backplane Current (mA) at 24V 70 mA

Input Resolution16 bits (unipolar)15 bits + sign (bipolar)

Normal Mode Rejection Ratio -50 dB at 50 and 60 Hz with the 10 Hz filter selected, respectively

Input ImpedanceCurrent Input: 250 ΩVoltage Input: 220 Ω

Accuracy Drift w/Temp.Current Input: ±0.0045%/°CVoltage Input: ±0.003%/°C

Non-linearity, Input ±0.03%

Input Repeatability ±0.03%‡

Module Error over Full Temperature Range±0.03% - Voltage±0.05% - Current

Input Channel ConfigurationVia configuration software screen or the user program (by writing a unique bit patterninto the module’s configuration file). Refer to your controller’s user manual todetermine if user program configuration is supported.

CalibrationThe module performs autocalibration on channel enable and on a configuration changebetween channels

Diagnostics Type Over- or under-range by bit reporting, process alarms

Power Supply Distance Rating 8 modules§

Isolation Voltage500V ac or 710V dc for 1 min (qualification test), 30V ac/30V dc working voltage (IECClass 2 reinforced insulation), input group to bus

✶The over- or under-range flag will come on when the normal operating range (over/under) is exceeded. The module willcontinue to convert the analog input up to the maximum full scale range. The flag automatically resets when within thenormal operating range.�The over- or under-range flag will come on when the normal operating range (over/under) is exceeded. The module will

continue to convert the analog input up to the max full scale range. The flag automatically resets when within the normaloperating range.

‡Repeatability is the ability of the input module to register the same reading in successive measurements for the same inputsignal.

§The module may not be more than 8 modules away from the system power supply.

37

Publication 1769-SG002E-EN-P — January 2007

1769-IF8 Specifications

Wiring Mixed Transmitter Inputs

Page 38: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

38

Publication 1769-SG002E-EN-P — January 2007

1769-OF2 Analog Output Module

Attribute Value

Voltage Category/Type, Output

±10V dc (±10.5V dc full scale)0…10V dc (-0.5…10.5V dc full scale)0…5V dc (-0.5…5.25V dc full scale)1…5V dc (0.5…5.25V full scale)

Current Range, Analog Output0…20 mA or 4…20 mA0…21 mA or 3.2…21 mA, full-scale

Number of Outputs 2

Backplane Current (mA) at 5V 120 mA

Backplane Current (mA) at 24V 120 mA✶

Output Resolution

14 bits (unipolar); 14 bits plus sign (bipolar)±10V dc: Sign + 14 bits, 0.64 mV0 to +5V dc: Sign + 13 bits, 0.64 mV0 to +10V dc: Sign + 14 bits, 0.64 mV+4 to +20 mA: Sign + 14 bits, 1.28 μA+1 to +5V dc: Sign + 13 bits, 0.64 mV0 to +20 mA: Sign + 14 bits, 1.28 μA

Output Conversion Type Sigma-Delta

Step Response to 63% of FS, Output Current or Voltage Output: 2.9 ms�

Current Load on Voltage Output, Max. 10 mA

Resistive Load on Current Output 0…500 Ω‡

Load Range, Voltage Output >1 kΩ at 10V dc

Inductive Load 0.1 mH

Output Capacitance 1 μF

Calibration None required

Accuracy Drift w/Temp.Current Output: ±0.0058% Full Scale/°CVoltage Output: ±0.0086% Full Scale/°C

Non-linearity, Output ±0.05% full scale

Output Repeatability ±0.05%§

Module Error over Full Temperature Range±0.8% - Voltage±0.55% - Current

Open Circuit Protection Yes

Short Circuit Protection (Yes/No) Yes

Overvoltage Protection Yes

Diagnostics TypeOver- or under-range by bit reportingOutput wire broken or load resistance high by bit reporting (current mode only)

Power Supply Distance Rating 8 modules

Isolation Voltage500V ac or 710V dc for 1 minute (qualification test), 30Vac/30Vdc working voltage (IECClass 2 reinforced insulation), output group to bus

✶If the optional 24V dc Class 2 power supply is used, the 24V dc current draw from the bus is 0 mA.�Step response is the period of time between when the D/A converter was instructed to go from minimum to full range until

the device is at 63% of full range.‡Includes wire resistance.§Repeatability is the ability of the output module to reproduce output readings when the same controller value is applied to it

consecutively, under the same conditions and in the same direction.

Page 39: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

39

Publication 1769-SG002E-EN-P — January 2007

1769-OF4CI Isolated Analog Current OutputModule

Attribute Value

Current Range, Analog Output0…20 mA, 4…20 mA0…21 mA, 3.2…21 mA full scale✶

Number of Outputs 4

Backplane Current (mA) at 5V 145 mA

Backplane Current (mA) at 24V 140 mA

Output Resolution16 bits (unipolar)+4…+20 mA: 15.59 bits, 0.324 μA/bit0…+20 mA: 15.91 bits, 0.324 μA/bit

Output Conversion Rate 10 ms

Step Response to 63% of FS, Output Current Output: <2.9 ms

Resistive Load on Current Output 0…500 Ω�

Inductive Load 0.1 mH

Calibration None required

Non-linearity, Output ±0.05% (in percent full scale)

Output Repeatability ±0.05% (in percent full scale)‡

Module Error over Full Temperature Range ±0.55%

Open Circuit Protection Yes

Short Circuit Protection (Yes/No) Yes

Overvoltage Protection Yes

Diagnostics TypeOver - or under-range/Clamps Exceeded by bit reportingOutput wire broken or load resistance high by bit reporting

Power Supply Distance Rating 8 modules

Isolation Voltage 500V dc

✶The over- or under-range flag will come on when the normal operating range (over/under) is exceeded. The module willcontinue to convert the analog output up to the maximum full scale range. The flag automatically resets when within thenormal operating range unless configured to latch.�Includes wire resistance.‡Repeatability is the ability of the output module to reproduce output readings when the same controller value is applied to it

consecutively, under the same conditions and in the same direction.

Page 40: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

40

Publication 1769-SG002E-EN-P — January 2007

1769-OF8C Analog Output Current Module

Attribute Value

Current Range, Analog Output0…20 mA or 4…20 mA0…21 mA or 3.2…21 mA, full-scale

Number of Outputs 8

Backplane Current (mA) at 5V 145 mA

Backplane Current (mA) at 24V 160 mA✶

Output Resolution16 bits (unipolar)4…20 mA: 15.59 bits, 0.323 μA/bit0…20 mA: 15.91 bits, 0.323 μA/bit

Output Conversion Rate 5 ms

Step Response to 63% of FS, Output Current Output: <2.9 ms

Resistive Load on Current Output 0…500 Ω�

Inductive Load 0.1 mH max

Calibration None required

Accuracy Drift w/Temp. Current Output: ±0.0058% Full Scale/°C

Non-linearity, Output ±0.05%

Output Repeatability ±0.05%‡

Module Error over Full Temperature Range ±0.55%

Open Circuit Protection Yes

Short Circuit Protection (Yes/No) Yes

Overvoltage Protection Yes

Diagnostics TypeOver- or under-range by bit reportingOutput wire broken or load resistance high by bit reporting

Power Supply Distance Rating 8 modules

Isolation Voltage500V ac or 710V dc for 1 minute (qualification test), 30Vac/30Vdc working voltage (IECClass 2 reinforced insulation), output group to bus

✶If the optional 24V dc Class 2 power supply is used, the 24V dc current draw from the bus is 0 mA.�Includes wire resistance.‡Repeatability is the ability of the output module to reproduce output readings when the same controller value is applied to it

consecutively, under the same conditions and in the same direction.

Page 41: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

41

Publication 1769-SG002E-EN-P — January 2007

1769-OF4VI Isolated Analog Voltage OutputModule

Attribute Value

Voltage Range, Analog Output-10.5…10.5V-0.5…25V

Number of Outputs 4

Backplane Current (mA) at 5V 145 mA

Backplane Current (mA) at 24V 75 mA

Output Resolution

16 bits (unipolar), 15 bits + sign (bipolar)-10…+10V, 15.89 bits, 329 μV/bit0…+5V, 13.89 bits, 329 μV/bit0…+10V, 14.89 bits, 329 μV/bit+1…+5V, 13.57 bits, 329 μV/bit

Output Conversion Rate 10 ms

Step Response to 63% of FS, Output Voltage Output: <2.9 ms

Resistive Load on Current Output 2000 Ω, min

Inductive Load 0.1 mH max

Calibration None required

Non-linearity, Output ±0.05%

Output Repeatability ±0.05%

Module Error over Full Temperature Range ±0.80%

Open Circuit Protection Yes

Short Circuit Protection (Yes/No) Yes

Overvoltage Protection Yes

Diagnostics Type Over- or under-range/Clamps Exceeded by bit reporting

Power Supply Distance Rating 8 modules

Isolation Voltage 500V dc

Page 42: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

42

Publication 1769-SG002E-EN-P — January 2007

1769-OF8V Analog Output Voltage Module

Attribute Value

Voltage Range, Analog Output

±10V dc (±10.5V dc full scale)0…10V dc (-0.5…10.5V dc full scale)0…5V dc (-0.5…5.25V dc full scale)1…5V dc (0.5…5.25V full scale)

Number of Outputs 8

Backplane Current (mA) at 5V 145 mA

Backplane Current (mA) at 24V 125 mA✶

Output Resolution

16 bits (unipolar)±10V dc: 15.89 bits, 330 μV/bit0…5V dc: 13.89 bits, 330 μV/bit0…10V dc: 14.89 bits, 330 μV/bit1…5V dc: 13.57 bits, 330 μV/bit

Output Conversion Rate 5 ms

Step Response to 63% of FS, Output Voltage Output: <2.9 ms

Inductive Load 0.1 mH max

Calibration None required

Accuracy Drift w/Temp. Voltage Output: ±0.0086% Full Scale/°C

Non-linearity, Output ±0.05%

Output Repeatability ±0.05%�

Module Error over Full Temperature Range ±0.8%

Open Circuit Protection Yes

Short Circuit Protection (Yes/No) Yes

Overvoltage Protection Yes

Diagnostics Type Over- or under-range by bit reporting

Power Supply Distance Rating 8 modules

Isolation Voltage500V ac or 710V dc for 1 minute (qualification test), 30Vac/30Vdc working voltage (IECClass 2 reinforced insulation), output group to bus

✶If the optional 24V dc Class 2 power supply is used, the 24V dc current draw from the bus is 0 mA.�Repeatability is the ability of the output module to reproduce output readings when the same controller value is applied to it

consecutively, under the same conditions and in the same direction.

Page 43: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

43

Publication 1769-SG002E-EN-P — January 2007

1769-IF4XOF2 Analog Combination Input/OutputModule

Wiring Differential Inputs

Wiring Single-ended Sensor/Transmitter Inputs

Wiring Mixed Transmitter Inputs

Page 44: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

44

Publication 1769-SG002E-EN-P — January 2007

Wiring Analog Outputs

1769-IF4XOF2 Input Specifications

Attribute ValueVoltage Range, Analog Input 0…10.5V dc✶

Current Range, Analog Input 0…21 mA, full-scale�

Number of Inputs 4

Backplane Current (mA) at 5V 120 mA

Backplane Current (mA) at 24V 160 mA

Input Resolution 8 bits plus sign‡

Normal Mode Rejection Ratio None

Input ImpedanceCurrent Input: 150 ΩVoltage Input: 150 Ω

Accuracy Drift w/Temp.Current Input: ±0.006% (±0.01% Full Scale)/°CVoltage Input: ±0.006% (±0.01% Full Scale)/°C

Non-linearity, Input ±0.4% full scale

Input Repeatability Input: ±0.4%§

Calibration Not required

Diagnostics TypeInput: Overrange by bit reportingOutput: Overrange by bit reporting

Power Supply Distance Rating 8 modules

Isolation Voltage500V ac or 710V dc for 1 minute, 30Vac/30Vdc working voltage (IEC Class 2 reinforced insulation),input to bus and output to bus.

✶The over-range flag will come on when the normal operating range is exceeded. The module will continue to convert theanalog input up to the maximum full scale range. The flag automatically resets when within the normal operating range.�The over-range flag will come on when the normal operating range is exceeded. The module will continue to convert the

analog input up to the maximum full scale range. The flag automatically resets when within the normal operating range.‡Sign is always positive.§Repeatability is the ability of the input module to register the same reading in successive measurements for the same input

signal.

Page 45: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

45

Publication 1769-SG002E-EN-P — January 2007

1769-IF4XOF2 Output Specifications

Attribute ValueVoltage Range, Analog Output 0…10.5V dc✶

Current Range, Analog Output 0…21 mA, full-scale�

Number of Outputs 2

Backplane Current (mA) at 5V 120 mA

Backplane Current (mA) at 24V 160 mA

Output Resolution 8 bits plus sign‡

Output Conversion Type Resistor String

Current Load on Voltage Output, Max. 10 mA

Resistive Load on Current Output 0…300 Ω§

Load Range, Voltage Output >1 kΩ @ 10V dc

Inductive Load 0.1 mH

Output Capacitance 1 μF

Calibration Not required

Accuracy Drift w/Temp.Current Input: ±0.006% (±0.01% Full Scale)/°CVoltage Input: ±0.006% (±0.01% Full Scale)/°C

Non-linearity, Output ±0.4% full scale

Output Repeatability ±0.05%♣

Open Circuit Protection Yes

Short Circuit Protection (Yes/No) Yes

Diagnostics TypeInput: Overrange by bit reportingOutput: Overrange by bit reporting

Power Supply Distance Rating 8 modules

Isolation Voltage500V ac or 710V dc for 1 minute, 30Vac/30Vdc working voltage (IEC Class 2 reinforcedinsulation), input to bus and output to bus.

✶Repeatability is the ability of the output module to reproduce output readings when the same controller value is applied to itconsecutively, under the same conditions and in the same direction.�The over-range flag will come on when the normal operating range is exceeded. The module will continue to convert the

analog out up to the maximum full scale range. The flag automatically resets when within the normal operating range.‡Sign is always positive. Bit 15 = 0.§Includes wire resistance.♣Repeatability is the ability of the output module to reproduce output readings when the same controller value is applied to it

consecutively, under the same conditions and in the same direction.

Page 46: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

46

Publication 1769-SG002E-EN-P — January 2007

1769-IT6 Thermocouple Input Module

The module contains a removable terminal block. Channels are wired as differentialinputs. Two cold-junction compensation (CJC) sensors are attached to the terminalblock to enable accurate readings from each channel. These sensors compensate foroffset voltages introduced into the input signal as a result of the cold junction wherethe thermocouple wires are connected to the module.

Important: For proper operation, the CJC sensors must be installed on thethermocouple module.

Attribute ValueNumber of Inputs 6, plus 2 cold junction sensors

Backplane Current (mA) at 5V 100 mA

Backplane Current (mA) at 24V 40 mA

Input Conversion Type Delta-Sigma

Input Filtering Programmable notch filter with multiple frequencies.

Normal Mode Rejection Ratio85 dB (minimum) at 50 Hz (with 10 Hz or 50 Hz filter)85 dB (minimum) at 60 Hz (with 10 Hz or 60 Hz filter)

Common Mode Rejection Ratio115 dB (minimum) at 50 Hz (with 10 Hz or 50 Hz filter)115 dB (minimum) at 60 Hz (with 10 Hz or 60 Hz filter)

Common Mode Voltage ±10V dc per channel✶

Non-linearity, Input ±0.03% full scale

Input Repeatability ±0.03%�

Open Circuit Detection Time 7 ms…2.1 s ‡

CalibrationThe module performs autocalibration upon power-up and whenever a channel is enabled. Themodule can also be programmed to calibrate every five minutes using the Enable/Disable CyclicCalibration bit.

Diagnostics Type Over- or underrange and open circuit by bit reporting.

Power Supply Distance Rating 8 modules

✶For proper operation, both the plus and minus input terminals must be within ±10V dc of analog common.�Repeatability is the ability of the input module to register the same reading in successive measurements for the same input

signal.‡Open circuit detection time is equal to channel update time, which is based on filter frequency.

Page 47: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

47

Publication 1769-SG002E-EN-P — January 2007

Data Formats

Choose from these data formats:

� Engineering units x 1 (in 0.1°C, 0.1°F or 0.01 mV)

� Engineering units x 10 (in °C, °F, or 0.1 mV)

� Scaled-for-PID (0...16,383)

� Percent of full-scale (0...10,000)

� Raw/proportional data (-32,767...32,767)

Repeatability

Input Type Repeatability for 10 Hz Filter✶

J ±0.1 °C (±0.18 °F)N (-110…1300 °C [-166…2372 °F]) ±0.1 °C (±0.18 °F)N (-210…-110 °C [-346…-166 °F]) ±0.25 °C (±0.45 °F)T (-170…400 °C [-274…752 °F]) ±0 .1 °C (±0.18 °F)T (-270…-170 °C [-454…-274 °F]) ±1.5 °C (±2.7 °F)K (-270…1370 °C [-454…2498 °F]) ±0.1 °C (±0.18 °F)K (-270…-170 °C [-454…-274 °F]) ±2.0 °C (±3.6 °F)E (-220…1000 °C [-364…1832 °F]) ±0.1 °C (±0.18 °F)E (-270…-220 °C [-454…-364 °F]) ±1.0 °C (±1.8 °F)S and R ±0.4 °C (±0.72 °F)C ±0.7 °C (±1.26 °F)B ±0.2 °C (±0.36 °F)±50 mV ±6 μV±100 mV ±6 μV

✶Repeatability is the ability of the input module to register the same reading in successive measurements for the same inputsignal.

Repeatability at any other temperature in the 0…60 °C (32…140 °F) range is the same as long as the temperature is stable.

Input Type

Engineering Units x 1 Engineering Units x 10

0.1 °C 0.1 °F 1.0 °C 1.0 °F

J -2100...12,000 -3460...21,920 -210...1200 -346...2192K -2700...13,700 -4540...24,980 -270...1370 -454...2498T -2700...4000 -4540...7520 -270...400 -454...752E -2700...10,000 -4540...18,320 -270...1000 -454...1832R 0...17,680 320...32,140 0...1768 32...3214S 0...17,680 320...32,140 0...1768 32...3214B 3000...18,200 5720...32,767✶ 300...1820 572...3308N -2100...13,000 -3460...23,720 -210...1300 -346...2372C 0...23,150 320...32,767✶ 0...2315 32...4199

±50 mV -5000...5000� -500...500�±100 mV -10,000...10,000� -1000...1000�

✶Type B and C thermocouples cannot be represented in engineering units x 1 (°F) above 3276.7 °F; therefore, it will be treatedas an over-range error.�When millivolts are selected, the temperature setting is ignored. Analog input data is the same for °C or °F selection.

Page 48: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

48

Publication 1769-SG002E-EN-P — January 2007

Inputs and Ranges

Input Type Range

J -210…1200 °C (-346…2192 °F)K -270…1370 °C (-454…2498 °F)T -270…400 °C (-454…752 °F)E -270…1000 °C (-454…1832 °F)R 0…1768 °C (32…3214 °F)S 0…1768 °C (32…3214 °F)B 300…1820 °C (572…3308 °F)N -210…1300 °C (-346…2372 °F)C 0…2315 °C (32…4199 °F)±50 mV -50…50 mV±100 mV -100…100 mV

Page 49: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

49

Publication 1769-SG002E-EN-P — January 2007

Input Type

Autocalibration EnabledAccuracy for 10, 50, and 50 Hz Filters, Max.

Autocalibration DisabledTemperature Drift, Max.

25 °C (77 °F) 0…60 °C (32…140 °F) 0…60 °C (32…140 °F)

J (-210…1200 °C [-346…2192 °F])

±0.6 °C (± 1.1 °F) ±0.9 °C (± 1.7 °F)±0.0218 °C/°C (±0.0218°F/°F)

N (-200…1300 °C [-328…2372 °F])

±1.0 °C (± 1.8 °F) ±1.5 °C (±2.7 °F)±0.0367 °C/°C (±0.0367°F/°F)

N (-210…-200 °C [-346…-328 °F])

±1.2 °C (±2.2 °F) ±1.8 °C (±3.3 °F)±0.0424 °C/°C (±0.0424°F/°F)

T (-230…400 °C [-382…752°F])

±1.0 °C (± 1.8 °F) ±1.5 °C (±2.7 °F)±0.0349 °C/°C (±0.0349°F/°F)

T (-270…-230 °C [-454…-382 °F])

±5.4 °C (± 9.8 °F) ±7.0 °C (±12.6 °F)±0.3500 °C/°C (±0.3500°F/°F)

K (-230…1370 °C [-382…2498 °F])

±1.0 °C (± 1.8 °F) ±1.5 °C (±2.7 °F)±0.4995 °C/°C [±0.4995°F/°F]

K (-270…-225 °C [-454…-373 °F])

±7.5 °C (± 13.5 °F) ±10.0 °C (± 18.0 °F)±0.0378 °C/°C (±0.0378°F/°F)

E (-210…1000 °C [-346…1832 °F])

±0.5 °C (± 0.9 °F) ±0.8 °C (±1.5 °F)±0.0199 °C/°C (±0.0199°F/°F)

E (-270…-210°C [-454…-346°F])

±4.2 °C (± 7.6 °F) ±6.3 °C (±11.4 °F)±0.2698 °C/°C (±0.2698°F/°F)

R ±1.7 °C (± 3.1 °F) ±2.6 °C (± 4.7 °F)±0.0613 °C/°C (±0.0613°F/°F)

S ±1.7 °C (± 3.1 °F) ±2.6 °C (± 4.7 °F)±0.0600 °C/°C (±0.0600°F/°F)

C ±1.8 °C (±3.3 °F) ±3.5 °C (±6.3 °F)±0.0899 °C/°C (±0.0899°F/°F)

B ±3.0 °C (±5.4 °F) ±4.5 °C (±8.1 °F)±0.1009 °C/°C (±0.1009°F/°F)

±50 mV ±15 μV ±25 μV ±0.44 μV/°C (±0.80 μV/°F)±100 mV ±20 μV ±30 μV ±0.69 μV/°C (±1.25 μV/°F)

Accuracy

Page 50: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

50

Publication 1769-SG002E-EN-P — January 2007

1769-IR6 RTD Input Module

Two-wire RTD Configuration

Three-wire RTD Configuration

Each channel is individually configurable via software for two- or three-wire RTD ordirect-resistance input devices. Channels are compatible with four-wire sensors, butthe fourth sense wire is not used. Two programmable-excitation current values (0.5mA and 1.0 mA) are provided, to limit RTD self-heating.

Important: The module accepts input from RTDs with up to three wires. If yourapplication requires a four-wire RTD, one of the two lead compensation wires is notused, and the RTD is treated like a three-wire sensor. The third wire provides leadwire compensation.

When configured for RTD inputs, the module can convert the RTD readings intolinearized digital-temperature readings in °C or °F. When configured for resistanceanalog inputs, the module can convert voltages into linearized resistance values inohms. The module assumes that the direct resistance input signal is linear prior toinput to the module.

Page 51: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

51

Publication 1769-SG002E-EN-P — January 2007

Two-wire Potentiometer Configuration

Three-wire Potentiometer Configuration

Four-wire RTD Configuration

Page 52: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

52

Publication 1769-SG002E-EN-P — January 2007

Two-wire RTD Configuration

Three-wire RTD Configuration

Each channel is individually configurable via software for two- or three-wire RTD ordirect-resistance input devices. Channels are compatible with four-wire sensors, butthe fourth sense wire is not used. Two programmable-excitation current values (0.5mA and 1.0 mA) are provided, to limit RTD self-heating.

Important: The module accepts input from RTDs with up to three wires. If yourapplication requires a four-wire RTD, one of the two lead compensation wires is notused, and the RTD is treated like a three-wire sensor. The third wire provides leadwire compensation.

When configured for RTD inputs, the module can convert the RTD readings intolinearized digital-temperature readings in °C or °F. When configured for resistanceanalog inputs, the module can convert voltages into linearized resistance values inohms. The module assumes that the direct resistance input signal is linear prior toinput to the module.

Page 53: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

53

Publication 1769-SG002E-EN-P — January 2007

Three-wire Potentiometer Configuration

Four-wire RTD Configuration

Two-wire Potentiometer Configuration

Page 54: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

54

Publication 1769-SG002E-EN-P — January 2007

1769-IR6 Specifications

Data Formats

Choose from these data formats:

� Engineering units x 1 (in 0.1 °C, 0.1 °F or 0.1 Ω)

� Engineering units x 10 (in 1.0 °C, 1.0 °F, or 1.0 Ω)

� Scaled-for-PID (0…16,383)

� Percent of full-scale (0…10,000)

� Raw/proportional data (-32,767…32,767)

Input Type

Engineering Units x 1 Engineering Units x 10

0.1 °C 0.1 °F 1.0 °C 1.0 °F

100 Ω Platinum 385

-2000…8500 -3280…15,620 -200…850 -328…1562200 Ω Platinum 385500 Ω Platinum 3851000 Ω Platinum 385100 Ω Platinum 3916

-2000…6300 -3280…11,660 -200…630 -328…1166200 Ω Platinum 3916500 Ω Platinum 39161000 Ω Platinum 391610 Ω Copper 426 -1000…2600 -1480…5000 100…260 -148…500120 Ω Nickel 618 -1000…2600 -1480…5000 100…260 -148…500120 Ω Nickel 672 -800…2600 -1120…5000 -80…260 -112…500604 Ω Nickel Iron 518 -1000…2000 -3280…1560 -100…200 -328…156

Attribute ValueNumber of Inputs 6

Backplane Current (mA) at 5V 100 mA

Backplane Current (mA) at 24V 45 mA

Input Conversion Type Sigma-Delta

Input Filtering Low pass digital filter with programmable notch filter.

Input Resolution Input filter and configuration dependent

Normal Mode Rejection Ratio70 dB minimum at 50 Hz with the 10 or 50 Hz filter selected70 dB minimum at 60 Hz with the 10 or 60 Hz filter selected

Common Mode Rejection Ratio110 dB minimum at 50 Hz with the 10 or 50 Hz filter selected110 dB minimum at 60 Hz with the 10 or 60 Hz filter selected

Common Mode Voltage ±10V dc per channel

Non-linearity, Input ±0.5% full scale

Input Repeatability

±0.01 °C (0.018 °F) for Ni and NiFe±0.2 °C (0.36 °F) for other RTD inputs±0.04 W for 150 W resistances±0.2 W for other resistances✶

Open Circuit Detection Time 6 ms…303 s�

CalibrationThe module performs autocalibration on channel enable and on a configuration change betweenchannels. You can also program the module to calibrate every five minutes.

Diagnostics Type Over- or under-range or broken input by bit reporting.

Power Supply Distance Rating 8 modules

✶Repeatability is the ability of the module to register the same reading in successive measurements for the same input signal.�Open-circuit detection time is equal to channel update time.

Page 55: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

55

Publication 1769-SG002E-EN-P — January 2007

Accuracy

Input Type

Autocalibration EnabledScaled Accuracy, Max.

Autocalibration DisabledTemperature Drift, Max.

25 °C (77 °F) 0...60 °C (32...140 °F) 0...60 °C (32...140 °F)

100 Ω Platinum 385

±0.5 °C (±0.9 °F) ±0.9 °C (±1.62 °F) ±0.026 °C/°C (±0.026 °F/°F)200 Ω Platinum 385500 Ω Platinum 3851000 Ω Platinum 385100 Ω Platinum 3916

±0.4 °C (±0.72 °F) ±0.8 °C (±1.44 °F) ±0.023 °C/°C (±0.023 °F/°F)200 Ω Platinum 3916500 Ω Platinum 39161000 Ω Platinum 391610 Ω Copper 426 ±0.6 °C (1.08 °F) ±1.1 °C (1.98 °F) ±0.032 °C/°C (0.032 °F/°F)120 Ω Nickel 618 ±0.2 °C (±0.36 °F) ±0.4 °C (±0.72 °F) ±0.012 °C/°C (±0.012 °F/°F)120 Ω Nickel 672 ±0.2 °C (±0.36 °F) ±0.4 °C (±0.72 °F) ±0.012 °C/°C (±0.012 °F/°F)604 Ω Nickel Iron 518 ±0.3 °C (±0.54 °F) ±0.5 °C (±0.9 °F) ±0.015 °C/°C (±0.015 °F/°F)

When you use Platinum 385 RTDs with 0.5 mA excitation current, the module’saccuracy is:

� ±0.5 °C (0.9 °F) after you apply power to the module or perform anautocalibration at 25 °C (77 °F) ambient, with module operating temperature at 25°C (77 °F).

� ±[0.5 °C (0.9 °F) + DT ± 0.026 deg./°C (±0.026 deg./°F)] after you apply powerto the module or perform an autocalibration at 25 °C (77 °F) ambient, with moduleoperating temperature 0…60 °C (32…140 °F). DT is the temperature differencebetween the actual-module operating temperature and 25 °C (77 °F). The value0.026 deg./°C (±0.026 deg./°F) is the temperature drift shown in the table above.

� ±0.9 °C after you apply power to the module or perform an autocalibration at 60 °C(140 °F) ambient, with module operating temperature at 60 °C (140 °F).

Page 56: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

56

Publication 1769-SG002E-EN-P — January 2007

Cable Specifications

Description Belden 9501 Belden 9533 Belden 83503

Use� Two-wire RTDs and

potentiometers

� Three-wire RTDs andpotentiometers

� Short runs less than 30 m(100 ft) and normalhumidity levels

� Three-wire RTDs andpotentiometers

� Long runs greater than 30 m(100 ft) or high humiditylevels

ConductorsTwo 0.21 mm2 (24 AWG) tinnedcopper (7 x 32)

Three 0.21 mm2 (24 AWG)tinned copper (7 x 32)

Three 0.21 mm2 (24 AWG)tinned copper (7 x 32)

ShieldBeldfoil aluminum polyestershield with copper drain wire

Beldfoil aluminum polyestershield with copper drain wire

Beldfoil aluminum polyestershield with tinned braid shield

Insulation PVC S-R PVC TeflonJacket Chrome PVC Chrome PVC Red TeflonAgency Approvals NEC Type CM NEC Type CM NEC Art-800 Type CMPTemperature Rating 80 °C (176 °F) 80 °C (176 °F) 200 °C (392 °F)

RTD Standards

Input Type α‡IEC-751 1983,Amend. 2 1995 DIN 43760 1987

SAMA2StandardRC21-4-1966§

JapaneseIndustrialStandard JISC1604-1989

JapaneseIndustrialStandard JISC1604-1997 Minco♣

100 Ω Platinum 385

0.00385

X X X200 Ω Platinum 385 X X X500 Ω Platinum 385 X X X1000 Ω Platinum 385 X X X100 Ω Platinum 3916

0.03916

X200 Ω Platinum 3916 X500 Ω Platinum 3916 X1000 Ω Platinum 3916 X10 Ω Copper 426✶ 0.00426 X

120 Ω Nickel 618� 0.00618 X

120 Ω Nickel 672 0.00372 X604 Ω Nickel Iron 518 0.00518 X

✶Actual value at 0 °C (32 °F) is 9.042 Ω per SAMA standard RC21-4-1966.�Actual value at 0 °C (32 °F) is 100 Ω per SAMA standard RC21-4-1966.‡This is the temperature coefficient of resistance which is defined as the resistance change per Ω per °C.§Scientific Apparatus Makers Association.♣Minco type NA (Nickel) and Minco type FA (Nickel-Iron).

Page 57: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

57

Publication 1769-SG002E-EN-P — January 2007

Resistance Device Compatibility

Resistance Device TypeResistance Range(0.5 mA excitation)

Resistance Range(1.0 mA excitation)

150 Ω 0...150 Ω 0...150 Ω500 Ω 0...500 Ω 0...500 Ω1000 Ω 0...1000 Ω 0...1000 Ω3000 Ω 0...3000 Ω Not allowed

RTD and Resistance Input Ranges

Input Type✶Temperature Range(0.5 mA excitation)

Temperature Range(1.0 mA excitation)

100 Ω Platinum 385 -200…850 °C (-328…1562 °F) -200…850 °C (-328…1562 °F)200 Ω Platinum 385 -200…850 °C (-328…1562 °F) -200…850 °C (-328…1562 °F)500 Ω Platinum 385 -200…850 °C (-328…1562 °F) -200…850 °C (-328…1562 °F)1000 Ω Platinum 385 -200…850 °C (-328…1562 °F) Not allowed100 Ω Platinum 3916 -200…630 °C (-328…1166 °F) -200…630 °C (-328…1166 °F)200 Ω Platinum 3916 -200…630 °C (-328…1166 °F) -200…630 °C (-328…1166 °F)500 Ω Platinum 3916 -200…630 °C (-328…1166 °F) -200…630 °C (-328…1166 °F)1000 Ω Platinum 3916 -200…630 °C (-328…1166 °F) Not allowed10 Ω Copper 426 Not allowed -100…260 °C (-148…500 °F)

120 Ω Nickel 618� -100…260 °C (-148…500 °F) -100…260 °C (-148…500 °F)

120 Ω Nickel 672 -80…260 °C (-112…500 °F) -80…260 °C (-112…500 °F)604 Ω Nickel Iron 518 -200…180 °C (-328…338 °F) -100…200 °C (-148…392 °F)

✶Digits following the RTD type represent the temperature coefficient of resistance (Ω), which is defined as the resistance change per Ω per °C. Forinstance, platinum 385 refers to platinum RTD with α = 0.00385 Ω/Ω-°C, or simply 0.00385/°C.�Actual value at 0 °C (32 °F) is 100 Ω per DIN standard.

Page 58: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

58

Publication 1769-SG002E-EN-P — January 2007

1769-HSC High-speed CounterModule

Use the 1769-HSC when you need these features:

� Intelligent counter module with its own microprocessor and I/O that is capable ofreacting to high-speed input signals.

� Count and rate values can be used to activate up to four embedded outputs and 12virtual outputs based on user-defined ranges.

� Signals received at the inputs are filtered, decoded, and counted.

� Signals are also processed to generate rate and time-between-pulses (pulse interval)data.

� Counter module capable of interfacing with up to two channels of quadrature orfour channels of pulse/count inputs.

Input Specifications

Output Specifications

Attribute ValueBackplane Current (mA) at 5V 425 mA

Power Supply Distance Rating 4 modules

Attribute ValueVoltage Category/Type, Input 2

Current Range, Analog Input -30…+30V dc

Voltage, On-State Input, Max. 30V dc

Current, On-State Input, Max. 15 mA

Voltage, Off-State Input, Max. 1.0V dc

Current, Off-State Input, Max. 1.5 mA

Leakage Current, Off-State Input, Max 1.5 mA

Input Impedance, Nom. 1950 Ω

Input Pulse Width, Min. 250 ns

Input Phase Separation, Min. 131 ns

Isolation Voltage1200V ac or 1659V dc for 1s, 75V dc working voltage (IEC Class 2 reinforced insulation),input to bus, input to input, and output to bus.

Attribute ValueVoltage Category/Type, Output 5…30V dc

Current Range, Analog Output User Power - 0.1V dc

Current, On-State Output, Max.1 A per point4 A per module

Voltage Drop, On-State Output, Max. 0.5V dc

Leakage Current, Off-State Output, Max 5 μA

Reverse Polarity Protection 30V dc

Isolation Voltage1200V ac or 1659V dc for 1s, 75V dc working voltage (IEC Class 2 reinforced insulation),input to bus, input to input, and output to bus.

Page 59: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

59

Publication 1769-SG002E-EN-P — January 2007

Throughput and Timing

Operation Description Timing, Max.

Input file update time

The delay between the timethe module receives apulse and when theCompactbus count value isupdated.

1 ms

Output turn-on time

The time it takes for thereal output to reach 90%output voltage aftercommanded by themodule, not includingprocessor scan time.

400 μs

Output turn-off time

The time it takes for thereal output to reach 10%output voltage aftercommanded by themodule, not including theprocessor scan time.

200 μs

Rate Accuracy

This graph shows rate error at various frequencies.

� Of the lines that rise at low frequencies, the leftmost is a 10 second update time(CtrnCyclicRateUpdateTime = 10,000).

� The rightmost line is a 1 ms update time (CtrnCyclicRateUpdateTime = 1).

� The line that rises at high frequencies illustrates Ctr[n].PulseInterval.

Page 60: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

60

Publication 1769-SG002E-EN-P — January 2007

1769 CompactCombinationModule

1769-BOOLEAN Combination 24V dc SinkInput/Source Output BOOLEAN Control Module

General Specifications

Attribute Value

Closed Loop Time (digital filter = 0)Output on-state current ≥ 5 mA: 100 μs maxOutput on-state current < 5 mA: 150 μs max

Backplane Current (mA) at 5V 220 mA

Heat Dissipation3.55 Total W (The W per point, plus the minimum W, with allpoints energized.)

Power Supply Distance Rating 8 modules✶

Isolated GroupsGroup 1: inputs 0 to 7Group 2: outputs 0 to 3

Input Point to Output Point IsolationVerified by one of the following dielectric tests: 1200V ac for 1 sor 1697V dc for 1 s75V dc working voltage (IEC Class 2 reinforced insulation)

Vendor I.D. Code 1

Product Type Code 109

Product Code 37

✶The module may not be more than 8 modules away from the power supply or controller.

Page 61: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

61

Publication 1769-SG002E-EN-P — January 2007

Input Specifications

Attribute ValueVoltage Category/Type, Input 24V dc sinking✶

Voltage Range, On-State Input stbUCString::convert: Character with charcode: "8451" met

Number of Inputs8 real8 virtual

Digital Filter Time ConstantOFF to ON: 0 s, 100 μs, 200 μs, 500 μs, 1 ms, 2 ms, 4 ms, 8 msON to OFF: 0 s, 100 μs, 200 μs, 500 μs, 1 ms, 2 ms, 4 ms, 8 ms

Hardware Delay, MaxOFF to ON: 10 μsON to OFF: 10 μs

Voltage, Off-State Input, Max. 5V dc

Current, Off-State Input, Max. 1.5 mA

Voltage, On-State Input, Min. 10V dc

Current, On-State Input, Min. 2.0 mA

Inrush Current, Max. 250 mA

Impedance2.0 kΩ @ 24V dc, nom2.3 kΩ @ 30V dc, nom

IEC Input Compatibility Type 3

Input Point to Bus (CompactBus) IsolationVerified by one of the following dielectric tests: 1200V ac for 1 sor 1697V dc for 1 s75V dc working voltage (IEC Class 2 reinforced insulation)

✶Sinking Input - Sink describes the current flow between the I/O module and the field device. Sinking I/O circuits are drivenby a current sourcing field device. Field devices connected to the positive side (+V) of the field supply are sourcing fielddevices. EEuurrooppee:: DC sinking input and sourcing output module circuits are the commonly used options.

Output Specifications

Attribute ValueVoltage Category/Type, Input 24V dc sourcing✶

Voltage Range, On-State Output 20.4…26.4V dc

Number of Outputs 4

Signal On Delay, Max (resistive load) 10 μs, output on-state current≥ 5 mA

Signal Off Delay, Max (resistive load) 10 μs, output on-state current ≥ 5 mA

Leakage Current, Off-State Output, Max 1.0 mA @ 26.4V dc�

Current, On-State Output, Min. 1.0 mA

Voltage Drop, On-State Output, Max. 1.0V dc @ 1.0 A

Continuous Current per Point, Max0.5 A @ 60 °C (140 °F)1.0 A @ 30 °C (86 °F)Refer to the temperature derating curve.

Surge Current per Output, Max. 2.0 A (Repeatability is once every 2 s for a duration of 10 ms.)‡

Output Point to Bus (CompactBus) IsolationVerified by one of the following dielectric tests: 1200V ac for 1 sor 1697V dc for 1 s75V dc working voltage (IEC Class 2 reinforced insulation)

✶Sourcing Output - Source describes the current flow between the I/O module and the field device. Sourcing output circuitssupply current to sinking field devices. Field devices connected to the negative side (dc common) of the field power supplyare sinking field devices. EEuurrooppee:: DC sinking input and sourcing output module circuits are the commonly used options.�Typical Loading Resistor - To limit the effects of leakage current through solid state outputs, a loading resistor can be

connected in parallel with your load. Use a 5.6 kΩ, 1/2 W resistor for transistor outputs, 24V dc operation.‡Recommended Surge Suppression - Use a 1N4004 diode reverse-wired across the load for transistor outputs switching 24V

dc inductive loads. For additional details, refer to Industrial Automation Wiring and Grounding Guidelines, Allen-Bradleypublication 1770-4.1.

Page 62: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

62

Publication 1769-SG002E-EN-P — January 2007

Temperature Derating

The area within the curve represents the safe operating range for the module undervarious conditions of user-supplied voltages and ambient temperatures.

1769-BOOLEAN Module Maximum Output Amperes per Module versusTemperature

1769-BOOLEAN Module Maximum Output Amperes per Point versusTemperature

Page 63: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

63

Publication 1769-SG002E-EN-P — January 2007

1769-ARM AddressReserve Module

Use a 1769-ARM address reserve module in CompactLogix systems to cost-effectivelyreserve module slots. After creating an I/O configuration and user program, you canremove and replace any I/O module in the system with a 1769-ARM module once youinhibit the removed module in RSLogix 5000 programming software.

CommunicationModules

For DeviceNet connectivity, you can select from these communication modules.

1769-SDN DeviceNet Scanner Module

Attribute ValueBackplane Current (mA) at 5V 440 mA

DeviceNet Power Requirements, Max.90 mA @ 11V dc110 mA @ 25V dc(N.E.C. Class 2)

Communication Rate125k Kbps250k Kbps500k Kbps

Cable Type Allen-Bradley part no. 1485C-P1-Cxxx.✶

DeviceNet Communication Rate, Max.125 Kbps (500 meters max)500 Kbps (100 meters max)

Power Supply Distance Rating 4 modules

Isolation Voltage500V ac for 1 minute or 707V dc for 1 minute, 30V dc workingvoltage (IEC Class 2 reinforced insulation), DeviceNet to bus

Vendor I.D. Code 1

Product Type Code 12

Product Code 105

✶Refer to publication DN-2.5 for more information.

To Connect Cat. No.

CompactLogix controller to a DeviceNetnetwork

1769-SDN

Distributed 1769 I/O modules to aDeviceNet network

1769-ADN/B✶

ASCII devices over RS-232, RS-485, andRS-422 networks

1769-ASCII

Compact I/O modules to up to threeDPI/SCANport-enabled drives or powerproducts�

1769-SM1

Compact I/O modules to PowerFlex 4-class drives.‡

1769-SM2

Certifications: C-UL-US for Class I, Division 2, Group A,B,C,D Hazardous Locations,CE, C-Tick, ODVA

✶The series A 1769-ADN adapter does not support the 1769-OA16, 1769-OW16, 1769-IF4XOF2, or 1769-HSC I/Omodules.�The 1769-SM1 Compact I/O to DPI/SCANport module can be used with MicroLogix 1500, CompactLogix, or a remote

1769-based adapter, such as the 1769-ADN module.‡The 1769-SM2 Compact I/O to DSI module can be used with a MicroLogix 1500, CompactLogix, or remote 1769-based

adapter, such as the 1769-ADN module.

Cat.No.

Numberof Inputs Number of Outputs Backplane Current (mA) at 5V Power Supply Distance Rating

1769-ARM — — 60 mA 8 modules

Page 64: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

64

Publication 1769-SG002E-EN-P — January 2007

1769-ADN DeviceNet Adapter Module

Attribute ValueBackplane Current (mA) at 5V 450 mA

DeviceNet Power Requirements, Max.90 mA @ 24V dc (+4%)(N.E.C. Class 2)

Communication Rate125 Kbps250 Kbps500 Kbps

Cable Type Allen-Bradley part no. 1485C-P1-Cxxx.✶

I/O Module Capacity 30

Power Supply Distance Rating 5 modules

Isolation Voltage Tested at 710V dc for 60 s

Vendor I.D. Code 1

Product Type Code 12

Product Code 69

✶Refer to publication DN-2.5 for more information.

1769-ASCII Module

Attribute ValueBackplane Current (mA) at 5V 500 mA

Input Words 108

Output Words 108

Configuration Words 31

Number of Inputs2 full duplex (RS-232, RS-422)2 half duplex (RS-485)

Serial Input Voltage Signal

3…25V dc with respect to signal ground (SG) "0", Asserted, ON,Space, Active-3…-25V dc with respect to signal ground (SG) "1". Disasserted,OFF, Mark, Inactive

Cable Type Belden 8761 (shielded)

Power Supply Distance Rating 4 modules

Isolation Voltage50V continuousTested at 500V ac for 60 s, channel to channel, channels tosystem

Vendor I.D. Code 1

Product Type Code 109

Product Code 66

Page 65: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

65

Publication 1769-SG002E-EN-P — January 2007

1769-SM1 Module

Attribute ValueBackplane Current (mA) at 5V 280 mA✶

Backplane Current (mA) at 24V 60 mA�

Communication Interface Type SCANport Interface

Communication RateDPI or SCANport125 Kbps or 500 Kbps

Enclosure Type Rating IP20

Communication Channels 3 (any combination of DPI or SCANport)

Connecting Cable LengthSCANport Host (1336, 1305, etc.): 10 meters maxDPI Host (PowerFlex, etc.): 10 meters max

Cable Type 1202-Cxx

Power Supply Distance Rating 6 modules‡

✶Supplied by the controller.�Per channel, supplied by the DPI/SCANport host.‡The module may not be more than 6 modules away from the power supply.

Attribute Value

Backplane Current (mA) at 5V 350 mA✶

Backplane Current (mA) at 24V 0 mA

Communication Interface Type Modbus RTU interface

Communication Rate 300…38.4 Kbps

Enclosure Type Rating IP20

Communication Channels 3

Connecting Cable Length10 m max with 8 conductor cable (22-RJ45CBL-C20), 400 ft maxwith 2 conductor cable (AK-U0-RJ45-TB2P adapter)

Cable Type 22-RJ45CBL-C20 or AK-U0-RJ45-TB2P adapter

Power Supply Distance Rating 4 modules�

✶Supplied by the controller.�The module may not be more than 4 modules away from the power supply.

1769-SM2 Module

Page 66: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

66

Publication 1769-SG002E-EN-P — January 2007

Step 2 - Select:

� wiring system (instead of theterminal block that comes withmodule)

� PanelConnect modules and cables toconnect input modules to sensors

Selecting a Wiring System

Analog Wiring Systems

Digital Wiring Systems

Digital Wiring Systems with Field Removable Terminal Blocks

Page 67: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

67

Publication 1769-SG002E-EN-P — January 2007

Analog Wiring Systems with Field Removable Terminal Blocks

Bulletin 1492 Programmable Controller WiringSystems� Increases Machine Building Productivity

� Simplifies Design and Engineering Time

� Reduces Wiring Time and Wiring Errors

� Benefits From Quality-looking Panels

Page 68: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

68

Publication 1769-SG002E-EN-P — January 2007

Description

Benefits Reduced Wiring Time

Reduced Wiring Errors

Wiring system cables are pre-tested to ensure 100% accurate connections andeliminate the need for point-to-point checking of wiring. No more crossed wires andloose connections between the I/O module and the terminal block. Even one error inwiring 128 I/O points in a point-to-point system may require a complete check of thewiring. Wiring errors can take several minutes to track down and correct before thepanel is ready for startup. When IFMs and cables are snapped in place, they fit everytime — no need to find the wrong or loose connection, resulting in a much higherrate of success at system startup.

Wiring is completed in a fraction of the time when wiring systems are used ascompared with the traditional method of wiring each point to the I/O swing arm andfield-side terminal blocks. Pre-wired cables are factory-wired to the I/O wiring arm onone end and a connector for the Interface Module (IFM) on the other. IFMs enhancethe capability of the I/O systems with added terminations, field-side LED statusindicators, isolation circuits, overcurrent protection, and higher amp outputs. Bothstandard and specific build-to-order length cables are available, providing the correctlength for any panel in a neat, space-efficient wiring solution.

Connecting to Allen-Bradley I/O is convenient with Allen-Bradley Interface Modulesand Cables. Unlike conventional terminal blocks, they connect through pre-wiredcables to digital and analog I/O for the Bulletin 1746 SLC, Bulletin 1756 ControlLogix,Bulletin 1769 Compact I/O for CompactLogix and MicroLogix 1500, and Bulletin1771/PLC-5 platforms. The interface modules are mounted onto a standard DIN #3Rail. Pre-printed adhesive label cards containing field-wiring information are availablefor each interface module and I/O module combination. Wiring systems are availablefor over 100 different I/O modules and over 50 analog modules. In addition, we offera custom wiring system program for those applications that do not meet your systemrequirements.

Page 69: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

69

Publication 1769-SG002E-EN-P — January 2007

Labeling and Marking

Simplified Design

Design engineers can simplify their panel drawings by calling out an IFM and pre-wired cable instead of having to detail every single wire and terminal block on theirdrawings. Simplified panel drawings aid not only the installer, but also the endcustomer who receives the panel.

Pre-printed, I/O-specific adhesive label strips for quick marking of IFM terminals savelabor compared with point-to-point wiring that requires labor intensive wire markers.Pre-wired cables require no wire labels. Pre-printed I/O-specific labels ensure neat,easy-to-read identification of wires and I/O points for all users.The marking of traditional terminal blocks has even caused some OEMs to movetoward a high-tech approach of plotting markers, requiring additional equipment inthe form of a plotter system and a PC to run the plotter software.

Pre-wired cables eliminate the time and costs associated with stripping and cuttingwires. Routing wires is much easier with wiring systems, since engineers only have toworry about routing one pre-wired cable versus the 20 or 40 wires needed in thetraditional wiring method.

Reduced Wire Preparation and Routing

Cable interconnections for a wiring system can be up to 30 times faster to install thantraditional point-to-point wiring, enabling OEMs and panel builders using wiringsystems to build panels faster and produce more machines.

Increased Volume and Productivity

Normal terminal blocks can’t offer the benefits of IFMs, such as LED indication oneach I/O point. Wiring systems improve system startup and ease troubleshooting andmaintenance. Diagnostic capabilities in the form of fuses, blown fuse indication, andfield-side ON-State LEDs — in a reduced space — allow maintenance personnel toquickly locate faults, reduce downtime, and improve overall productivity.

Faster Troubleshooting and Easier Maintenance

Page 70: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

70

Publication 1769-SG002E-EN-P — January 2007

A wiring system involves an IFM and the cable, versus the block, barrier, jumper,markers, wires, and swing arms associated with traditional hardwired systems.Therefore, it requires fewer components and, in turn, less inventory and lowercarrying costs.

Design Flexibility

To develop a cost-effective system, the hardware components must meet the needs ofthe design engineer. Rockwell Automation provides the broadest range of digital andanalog systems in the industry. Allen-Bradley Wiring Systems deliver a lower life-cyclecost.

Fewer Parts, Less Inventory and Lower CarryingCost

The pre-wired cables and IFMs organize the wiring in your panel and provide aconsistent look. Pre-printed adhesive labels for the terminals neatly identify field-wiring connections, which correspond to the I/O module address. A large markingarea is also available for identifying I/O information on the IFM.

Quality-Looking Panels

An increasing trend in the industry is to pack more products into the same DIN Railspace. Wiring systems support this trend, as they require less DIN Rail space thantraditional terminal blocks. For example, if an OEM were to use a 40-point IFM inplace of 40 terminal blocks, DIN Rail space can be reduced by more than 50%. All IFMs have terminals for connecting the I/O field wiring. In addition, extra terminal,sensor, fusible IFMs, and relay IFMs contain common terminals that are used aspower busses for sensor and actuators. No additional terminal blocks are needed toprovide power to the sensors/actuators — saving valuable panel/DIN Rail space. To further reduce panel space, narrow IFMs (i.e., Cat. No. 1492-IFM20FN) have beendesigned. They require 45% less space than the standard length IFMs, making themwell-suited for tightly packed enclosures. The high density narrow IFMs have two rowsof 10 field-wiring terminals with an overall length of 60 mm (2.36 in.)

Increased DIN Rail Density

Page 71: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

71

Publication 1769-SG002E-EN-P — January 2007

Digital InterfaceModules (IFMs)

Digital IFMs are available with either a 20- or 40-pin cable connector. This isdetermined by the number of connections required for the I/O module.

40-pin Connection Interface Module

The number of terminals varies with the type of IFM — from one to four terminalsper I/O point.Standard terminal IFMs provide one field-side wiring terminal per programmablecontroller input or output point, as well as enough terminals for the I/O modulepower connections. The standard terminals are ideal for applications where the I/Odevice commons are terminated in the field or remotely from the I/O panel.

Standard Terminal Interface Module

Extra terminal IFMs provide two or four field-side terminals per input or outputpoint. Non-isolated IFMs have two terminals per input or output point. Isolated IFMshave two or four terminals per input or output.

Isolated IFMs have terminals isolated into 8 or 16 groups, which allows each group ofI/O devices to reference a different power source. The extra terminal IFMs arebeneficial in applications where the I/O devices are terminated within the same panelas the I/O modules — eliminating the need for many additional terminal blocks.

Page 72: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

72

Publication 1769-SG002E-EN-P — January 2007

Extra Terminal Interface Module

Sensor IFMs provide three field-side terminals per input point. The middle and lowerrows of the terminals are commoned together in groups of 18, and serve as powerbusses for 3-wire sensor types of devices — eliminating additional terminals, blocks,and jumpering systems.

Three-Level Sensor Terminal Interface Module

Page 73: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

73

Publication 1769-SG002E-EN-P — January 2007

Feed-ThroughDigital InterfaceModules

Feed-through IFMs provided the same capability as normal terminal blocks, but in amore condensed package.

Feed-through Standard Terminal ProductsFor 20-point Cat. No. 1492-IFM20F, 1492-IFM20FNFor 40-point Cat. No. 1492-IFM40F

Feed-through Extra Terminal ProductsFor 20-point

Cat. No. 1492-IFM20F-2For 40-point Cat. No. 1492-IFM40F-2

Feed-through Sensor Terminal Products For 20-point Cat. No. 1492-IFM20F-3For 40-point Cat. No. 1492-IFM40F-3

Page 74: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

74

Publication 1769-SG002E-EN-P — January 2007

Sensor Terminal IFM with 40-pin cable connectorfor 3-wire sensor devicesCat. No. 1492-IFM40F-3and Standard Terminal Narrow IFM with 20-pincable connectorCat. No.1492-IFM20FN

LED-IndicatingDigital InterfaceModules

Voltage-indicating LEDs are available on standard, extra terminal, and sensor IFMs.The LEDs provide field-side troubleshooting diagnostics: the on/off status of an inputdevice or the on/off status of the programmable controller output circuit. When usedin conjunction with the logic-side programmable controller LEDs, the IFM LEDs canhelp determine whether a problem resides in the I/O module or in the fielddevice/wiring. LED IFMs are available in both Isolated (Cat. No. 1492-IFM20DS24-4)and non-Isolated (Cat. No. 1492-IFM20D120) versions for 24V, 120V, and 240Vapplications.

LED Indicating Standard Terminal ProductsFor 20-point Cat. No. 1492-IFM20D24, 1492-IFM20D120, 1492-IFM20D120NFor 40-point Cat. No. 1492-IFM40D24

Page 75: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

75

Publication 1769-SG002E-EN-P — January 2007

LED Indicating Extra Terminal ProductsFor 20-pointCat. No. 1492-IFM20D24-2, 1492-IFM20D24A-2, 1492-IFM20D120-2,1492-IFM20D120A-2, 1492-IFM20D240-2, 1492-IFM20D240A-2For 40-pointCat. No. 1492-IFM40D24-2, 1492-IFM40D24A-2, 1492-IFM40D120-2,1492-IFM40D120A-2

LED Indicating Sensor Terminal ProductsFor 20-pointCat. No. 1492-IFM20D24-3For 40-pointCat. No. 1492-IFM40D24-3

20-pin cable connector ON-state LED Narrow module for 24VCat. No. 1492-IFM20D24N,20-point LED module for 120V Cat. No. 1492-IFM20D120,and 20-pin cable connector LED Isolated module for 24VCat. No. 1492-IFM20DS24-4

Page 76: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

76

Publication 1769-SG002E-EN-P — January 2007

LED Indicating 4 Terminal ProductsFor 20-pointCat. No. 1492-IFM20DS24-4, 1492-IFM20DS120-4For 40-pointCat. No. 1492-IFM40DS24-4, 1492-IFM40DS24A-4, 1492-IFM40DS120-4,1492-IFM40DS120A-4, 1492-IFM40DS240-4

A 40-pin cable connector ON-state LED module for 24VCat. No. 1492-IFM40D24,40-pin cable connector LED module for 120Vwith extra terminalsCat. No. 1492-IFM40D120-2,and 40-pin cable connector LED Isolated Input module for 24VCat. No. 1492-IFM40DS24A-4

Page 77: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

77

Publication 1769-SG002E-EN-P — January 2007

Fusible Digital IFMs Fusible modules provide a convenient method of adding overcurrent protections intoyour programmable controller wiring. These modules have 5 x 20 fuse holders on-board and are available with and without blown fuse indication. The 24V, 120V, and240V blown fuse indicators reduce the troubleshooting time to locate and replace ablown fuse on the IFM. Fusible modules have an easy-to-remove, transparentPlexiglass cover that prevents objects from contacting fuse circuitry under normaloperation. Removal of fuses from the standard fuse holder is aided by fuse pullers(fuses not provided). The fusible modules also have two or four terminals per I/Opoint to create a power bus for input and output load connections. Fusible modulesare available in both isolated (Cat. No. 1492-IFM20F-FS24-2) and nonisolated (Cat.No.1492-IFM20F-F24-2) versions. There are a select number of fusible IFMs availablefor input modules.

Fused Extra Terminal ProductsFor 20-pointCat. No. 1492-IFM20F-F-2,1492-IFM20F-F24-2, 1492-IFM20F-F24A-2, 1492-IFM20F-F120-2, 1492-IFM20F-F120A-2, 1492-IFM20F-F240-2, 1492-IFM20FS-F -2, 1492-IFM20FS-F24-2, 1492-IFM20FS-F24A-2For 40-pointCat. No. 1492-IFM40F-F-2, 1492-IFM40F-F24-2, 1492-IFM40F-F120-2, 1492-IFM40FS-F-2, 1492-IFM20FS-F24-2, 1492-IFM20FS-F120-2,1492-IFM20FS-F24-4, 1492-IFM20FS-F24A-4, 1492-IFM20FS-F120-41492-IFM20FS-F120A-4, 1492-IFM40FS-F240-4

Page 78: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

78

Publication 1769-SG002E-EN-P — January 2007

Fused 4 Terminal ProductsFor 20-point Cat. No. 1492-IFM20FS-F120-4, 1492-IFM20FS-F120A-4, 1492-IFM20FS-F240-4For 40-point Cat. No. 1492-IFM20FS-F24-4, 1492-IFM20FS-F24A-4, 1492-IFM20FS-F120-4,1492-IFM20FS-F120A-4, 1492-IFM40FS-F240-4, 1492-IFM40F-FS240A-4

40-pin cable connector Isolated Fusible module (no fuse blown indication)Cat. No. 1492-IFM40F-FS-2and 40-pin cable connector Isolated Fusible modulewith 24V blown fuse indicationCat. No. 1492-IFM40F-FS24A-2

RelayMaster/ExpanderXIMs Cat. No.Explanation forDigital I/O Modules

Relay master and expander XIMs are available for Bulletin 1746, 1756, 1769, and1771 digital output modules.Relay Master XIM — Provides 8 or 16 relay outputs for a digital output module.There are 16 relays with fusing.Expander XIM — In addition to the relay master XIM, an expander XIM provideseight additional outputs. There are three types of expander XIMs: eight-channel relays,eight-channel fusing, and eight-channel feed-through XIMs, sixteen channel relays,sixteen channel relays with fusing.

Page 79: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

79

Publication 1769-SG002E-EN-P — January 2007

Relay Masters

Relay Master withFusing

Relay Masters ProductsFor 20-point Cat. No. 1492-XIM2024-8R, 1492-XIM2024-16R, 1492-XIM20120-8R,1492-XIM20120-16RFor 40-point Cat. No. 1492-XIM4024-16R

Relay Master

Relay master XIMs feature field-replaceable relays with 120V or 24V rated coils. Thefield-side Form C contacts are rated 240V 10 A (de-rated to 12 A per adjacent pair onthe XIM). The Form C relay output provides isolated output channels and a differentvoltage level from one output channel to the next. Other features include coil-side LEDindicating the output module status, and transient suppression on each coil. Inaddition, some relay masters have 5x20 fuse holders so customers can fuse the outputcontacts.

Page 80: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

80

Publication 1769-SG002E-EN-P — January 2007

Relay Expanders Relay Expander (8)

Relay Expander ProductsCat. No. 1492-XIM24-8R,1492-XIM24-16RF,1492-XIM120-8R

Relay Expander (16)with Fusing

Relay Masters with Fuse Holders ProductsFor 20-point Cat. No. 1492-XIM2024-16RF, 1492-XIM20120-16RFFor 40-point Cat. No. 1492-XIM4024-16R

Relay Masters with Fuse Holders ProductsFor 20-point Cat. No. 1492-XIM2024-16RF, 1492-XIM20120-16RFFor 40-point Cat. No. 1492-XIM4024-16R

Page 81: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

81

Publication 1769-SG002E-EN-P — January 2007

Relay andExpandable DigitalInterface Modules,Continued

Fusible Expanders

Relay expander XIMs feature field-replaceable relays with 120V or 24V rated coils.The field-side Form C contacts are rated 240V 10 A (de-rated to 12 A per adjacentpair on the XIM). The Form C relay output provides isolated output channels and adifferent voltage level from one output channel to the next. Other features includecoil-side LED indicating the output module status, and transient suppression on eachcoil. In addition, a relay expander can have 5x20 fuse holders so customers can fusethe output contacts. An expander cable is provided for connection to the matingmodule.

The fusible expander modules feature eight 5 x 20 finger safe fuse holders, blown fuseindicators and extra terminals for landing two wires per field-side device. They areoffered with eight fuse holders for both 24V and 120V applications. An expander cableis provided for connection to its mating module.

Fused Expander ProductsCat. No. 1492-XIMF24-2, 1492-XIMF-120-2

Page 82: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

82

Publication 1769-SG002E-EN-P — January 2007

Feed-Through Expanders

The feed-through expander modules feature eight channels with extra terminals forlanding two wires per field-side device. An expander cable is provided for connectionto its mating module.

Feedthrough Expander ProductsCat. No. 1492-XIMF-2

Digital IFM Moduleswith FieldRemovable TerminalBlocks (RTBs)

Select groups of standard, fused and relay digital 1492 wiring system modules (referto Selection Tables) have field terminal blocks that can be removed (RTB). This RTBfeature can provide easier wiring of field devices in a control cabinet where the IFM islocated in a hard to reach area, or where hand-access is limited. It can also provideeasier and faster replacement of a damaged or defective 1492 wiring system module.The removable plug portion of the RTB assembly has a screw at each end to securelyfasten it to the RTB socket, which is mechanically secured to the module circuit boardhand housing. Modules are shipped with the RTB socket, but without the removableplug(s). Plugs are available with screw style or push-in style (June 2007) terminalsand must be ordered separately. Refer to the Selection Tables for the particular PLCI/O system of interest to determine which modules are offered with field RemovableTerminal Blocks.

All of the features available on fixed terminal block products (e.g. labels, agencycertification, etc.) are also provided for the removable terminal block 1492 wiringsystem modules.

I/O-Ready Cable and Standard Terminal Blocks

Page 83: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

83

Publication 1769-SG002E-EN-P — January 2007

Digital Pre-WiredCables

1492-Pre-Wired Cables are designed to minimize control wiring in a panel. Pre-Wiredcables, when used with an IFM, replace the point-to-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. Thepre-wired cables have a Removable Terminal Block or Wiring Arm at the PLC end ofthe cable and a cable connector on the other end to connect to the IFM. All of thepre-wired cables use a #22 AWG wire and are 100% tested for continuity to make aperfect connection every time. The digital pre-wired cables are offered in fourstandard lengths of 0.5, 1.0, 2.5, and 5.0 m to fit a variety of applications. Otherlength cables are also available as build to order products. Pre-wired cables areavailable for many of the 1746 SLC I/O, 1756 ControlLogix I/O, 1769 Compact I/O,MicroLogix 1500 base I/O, MicroLogix 1200 (1762-L40xx) embedded I/O, and 1771PLC-5 I/O.

Pre-wired Cable and Interface Module

Page 84: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

84

Publication 1769-SG002E-EN-P — January 2007

Ready-to-WireDigital Cables

Digital I/O Ready Cable

I/O-Ready Cables have a I/O Removable Terminal Block or Wiring Arm factory-wiredto one end to of the cable and free connectors on the other end for wiring intostandard terminal blocks or other type of connectors. I/O-Ready Cables haveindividual color-coded conductors for quick wire-to-terminal coordination. The I/O-Ready cables use #18 AWG conductors for higher current applications or longer cableruns. The I/O-Ready cables are offered in standard lengths of 1.0, 2.5, and 5.0 m to fita variety of applications. Other cable lengths are also available as build-to-orderproducts. Pre-wired cables are available for the Bulletin 1746 SLC I/O, Bulletin 1756ControlLogix I/O, Bulletin 1769 Compact I/O, MicroLogix 1500 base I/O, MicroLogix1200 (1762-L40xx) embedded I/O, and Bulletin1771 PLC-5 I/O.

IFM-Ready Cable

IFM-Ready Cables have a cable connector that attached to the IFM factorywired to oneend and free connectors ready to wire to I/O modules or other components on theother end. IFM-Ready Cables use #22 AWG wire and have individual color-codedconductors for quick wire-to-terminal coordination. The digital IFM-Ready Cables areoffered in standard lengths of 1.0, 2.5, and 5.0 m to fit a variety of applications. Othercable lengths are also available as build-to-order products.

IFM-Ready Cable and Interface Module

Page 85: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

85

Publication 1769-SG002E-EN-P — January 2007

Analog InterfaceModules (IFMs)

Feed-ThroughAnalog InterfaceModules

Analog IFMs are available with either 15- or 25-pin D-Shell connections. This isdetermined by the number of connections that are required by the I/O module.

Feed-through IFMs provide the same capability as normal terminal blocks but in amore condensed package. Standard terminal IFMs provide three field-side wiringterminals per programmable controller analog input or output point, which includesenough terminals for the device shield and power connections.

Standard Terminal 4-channel IFM with 15 con-nectionsCat. No. 1492-AIFM4-3and Isolated Standard Terminal 6-channel IFMwith 25 connectionsCat. No. 1492-AIFM6S-3, 1492-AIFM8-3

Standard Terminal 8-channel IFMwith 25 connections for 3-wire sensor devicesCat. No. 1492-AIFM8-3

Page 86: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

86

Publication 1769-SG002E-EN-P — January 2007

Fusible AnalogInterface Modules

Fused 4-channel module with 24V blown fuse indication,test points and 5 terminals per inputCat. No. 1492-AIFM4I-F-5and 8-channel input module with 24V blown fuseindication and 5 terminals per inputCat. No. 1492-AIFM8-F-5

Fusible analog interface input modules provide a convenient method to fuse the inputpower source on the field-side. The field-side power source is distributed throughindividual on-board 5 x 20 fuse holders. The AIFMs have a 24V DC blown fuseindicators to reduce the troubleshooting time required to locate and replace a blownfuse. Fusible modules have an easy-to-remove transparent Plexiglass cover to preventobjects from contacting fuse circuitry under normal operation. Standard fuse holdersreside in the IFM, aiding in the removal of a fuse with a fuse puller (fuses are notincluded). Isolation switch plugs, or “dummy fuses”, are also available to isolate aninput circuit once power is removed. In addition, once the circuit has been isolatedand power restored, the input loop current can be measured in 2-wire transmitterapplications. The fusible modules also have three or five terminals per I/O analoginput point to create a power bus for device shield and power connections.Analog fusible modules have an on-board DIP switch to easily connect unused inputsto the module common — reducing wiring on the field side. You no longer needextra jumper wires to properly terminate unused inputs as is recommended inBulletins 1746, 1756, 1769, and 1771 I/O. Inputs are jumped via a DIP switch on aper channel basis.

Analog Fused ProductsCat. No. 1492-AIFM4C-F-5, 1492-AIFM4F-F-5, 1492-AIFM8-F-5,1492-AIFM16-F-3, 1492-AIFM16-F-5, 1492-AIFMP1, 1492-AIFMQS

Page 87: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

87

Publication 1769-SG002E-EN-P — January 2007

Fusible AnalogInterface Modules,Continued

Fused 16-channel module with 24V blown fuse indication,test points and 3 terminals per inputCat. No. 1492-AIFM16-F-3and 16-channel input module with 24V blown fuseindication and 5 terminals per inputCat. No. 1492-AIFM16-F-5

Analog AIFMModules with FieldRemovable TerminalBlocks (RTBs)

Select groups of analog 1492 wiring system modules (refer to Selection Tables) havefield terminal blocks that can be removed (RTB). This RTB feature can provide easierwiring of field devices in a control cabinet where the IFM is located in a hard toreach area, or where hand-access is limited. It can also provide easier and fasterreplacement of a damaged or defective 1492 wiring system module. The removableplug portion of the RTB assembly has a screw at each end to securely fasten it to theRTB socket, which is mechanically secured to the module circuit board and housing.Modules hare shipped with the RTB socket, but without the removable plug(s). Plugsare available with screw style or push-in style (June 2007) terminals and must beordered separately. Refer to the Selection Tables for the particular PLC I/O system ofinterest to determine which modules are offered with field Removable TerminalsBlocks.

All of the features available on analog fixed terminal block products (e.g. labels,agency certification, etc.) are also provided for the removable terminal block 1492wiring system modules.

Page 88: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

88

Publication 1769-SG002E-EN-P — January 2007

ThermocoupleAnalog InterfaceModules

The Cat. No.1492-AIFM6TC-3 Thermocouple IFM for the Cat. No. 1756-IT6IControlLogix I/O module provides on-board cold junction compensation to allowthermocouples to be connected remotely while still correcting for temperature at thetermination point. The combination thermistor and isothermal bar acquiretemperature data at the AIFM for the thermocouple to adjust the input value.

Thermocouple 6-channel module with isothermalbar and 3 terminals per outputCat. No. 1492-AIFM6-TC-3

Page 89: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

89

Publication 1769-SG002E-EN-P — January 2007

Analog Pre-wiredCables

Bulletin 1492 Pre-wired Cables are designed to minimize control wiring in a panel.Pre-wired cables, when used with an Analog IFM, replace the pointto- point wiringbetween Allen-Bradley programmable controller I/O modules and individual terminalblocks. The pre-wired cables have a removable terminal block or wiring arm from thePLC on one end of the cable and a D-Shell connector with a slide-locking mechanismon the other to connect to the IFM. Most pre-wired cables use twisted pairs and allhave shield to aid noise immunity of the low-level analog signals. Most cables have aprepared drain wire with a ring lug at the I/O module end of the cable for convenientgrounding of the cable shield to the chassis. They are 100% tested for continuity tomake a perfect connection every time. The analog pre-wired cables are offered in fourstandard lengths of 0.5, 1.0, 2.5, and 5.0 m to fit a variety of applications. Otherlength cables are also available as build-to-order products. Pre-wired analog cablesare available for many of the Bulletin 1746 SLC I/O, Bulletin 1756 ControlLogix I/O,Bulletin 1769 Compact I/O for MicroLogix 1500, and Bulletin 1771 PLC-5 I/Omodules.

Relay and Expandable Modules

Relay and Expandable Interface Modules (XIM) were developed to maximize theeffectiveness of users’ applications that require output contact ratings greater than 2A. Driving large loads up to 10 A for applications such as motor starters is nowpossible with Bulletin 1492 Wiring Systems. In addition, the Relay Modules provide ameans to isolate output points.The Relay and Expandable product line consists of a Relay Master module andExpander Module(s) with expander cable. The Relay Master modules provide theconnection for the 20- or 40-pin cable connectors for the pre-wired cable. There arefive types of expander XIMs: eight-channel relay, sixteen-channel relay, eight-channelfused, sixteen-channel relay with fusing, and eight-channel feed-through.Expander Module capabilities are offered in eight-channel and sixteen-channelincrements. After using 8 or 16 channels of I/O for relays (master relay module),design engineers can use expander modules for the other I/O point needs. Theflexibility means that they work with relays, fuses, and feed-through modules. Inaddition, the expander modules can be added when system expansion is required.

StandardsCompliance andCertifications

� UL Component Recognized, File E113724, Guide No. NRAQ2

� CSA Certified, File LR1234, Class 3211-07

� UL Recognized per Canadian Standards (cUR), File E113724, Guide No. NRAQ8

� FM approved, J.I. 3000590✶

✶Relay modules do not have this approval.

Page 90: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

90

Publication 1769-SG002E-EN-P — January 2007

Catalog Number ExplanationCustom Wiring System Program1492 Custom Wiring Systems opens up a new capability for the Allen-Bradleycustomer. When standard wiring systems do not do the job, customers can ask formodification or a completely new design that fits their application requirements.

Through the Custom Wiring System Program, customers can provide their designinput for an interface module or cable with no up front fees and a minimum orderquantity of only thirty-five (35) units.

In addition, we use our “Fastrack Customer Solutions” capabilities which can have adesign in the customer’s hands within 8 to 10 weeks. The custom designs are donedirectly between the customer's engineer and the Rockwell Automation engineer. Wehave removed the middle man so we can get the design right the first time. Eachdesign is approved by the customer prior to starting manufacturing of the customer’scustom product. This is done through the customer reviewing bills of materials,schematics, and assembly drawings and signing them off. The distributor salesperson in kept in the loop but direct customer contact is a must during the designcycle. The process starts with the distributor and customer completing the “Requestfor Quote for Custom Interface Module and Cable” form. This form is then e-mailedinto [email protected] for processing within RockwellAutomation Marketing and Engineering.

UL and CSA certifications are also possible on the custom modules. Minimal fees mayapply.

This catalog provides reference to catalog number selection and configuration. Forthe fastest and most complete 1492 Wiring System Product Selection go tohttp://www.ab.com/raise http://www.ab.com/raise.This tool will provide:

� Catalog Number Configuration of Interface Modules and Appropriate Pre-WiredCables

� Field Side Wiring Diagrams for Each Interface Module

� Prewired Cable Pin-outs

� ABCAD Module Files

� Label Card Information

� User Documentation Specification for Each Interface Module

Page 91: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

c

Connector StyleCode Description

N Screw Style

P Push-in Style✶

✶ Available March 2006

91

Publication 1769-SG002E-EN-P — January 2007

Important: The following cat. no. breakdown is for explanatory purposes only. It isnot a product configurator. Not all combinations of fields are valid cat. nos. Use thisbreakdown for verification and explanation only.

1492 – RTB 20 – N

a b c

b

Number of Poles/TerminalCode

8

12

14

16

17

20

Important: Use the following tables as a product confiurator for pre-wired, and I/Omodule-ready cables for Bulletin 1762 MicroLogix 1200 40 I/O controller digitalI/O cables. All combination of these fields make valid product catalog numbers. Referto selection tables for IFM compatibility and ordering.

a

Removable Terminal Block Plug

Page 92: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

92

Publication 1769-SG002E-EN-P — January 2007

1492 – CAB 010 – A62

a b c

a

DigitalInterfaceCable

c

Cable TypeCode Description

A62, B62Pre-wired cables for Bulletin 1762 I/O controllers

X62I/O-ready cable for 1762-L40AWA, and -L40BWA

T62I/O-ready cable for 1762-L40AWA, -L40BXB, and -L40BWAoutputs

Important: Use the following tables as a product confiurator for pre-wired, and I/Omodule-ready cables for Bulletin 1764 MicroLogix 1500 base unit digital I/Ocables. All combination of these fields make valid product catalog numbers. Refer toselection tables for IFM compatibility and ordering.

b

Standard or Build-to-Order Length CablesCode Length Description

005 0.5 m (1.64 ft)

Standard Length010 1.0 m (3.28 ft)

025 2.5 m (8.20 ft)

050 5.0 m (16.40 ft)

001-020 0.1...2.0 m (0.328...6.56 ft)0.1 m (0.328 ft increments)

Build-to-Order Length020-100 2.0...10.0 m (6.56...32.8 ft)

0.5 m (1.64 ft increments)

100-990 10.0...99.0 m (32.8...374.72 ft)1.0 m (3.28 ft increments)

Page 93: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

93

Publication 1769-SG002E-EN-P — January 2007

DigitalInterfaceCable

Important: The following cat. no. breakdown is for explanatory purposes only. It isnot a product configurator. Not all combinations of fields are valid cat. nos. Use thisbreakdown for verification and explanation only.

1492 – CAB 010 – A64a b c

b

Standard or Build-to-Order Length CablesCode Length Description

005 0.5 m (1.64 ft)

Standard Length010 1.0 m (3.28 ft)

025 2.5 m (8.20 ft)

050 5.0 m (16.40 ft)

001-020 0.1...2.0 m (0.328...6.56 ft)0.1 m (0.328 ft increments)

Build-to-Order Length020-100 2.0...10.0 m (6.56...32.8 ft)

0.5 m (1.64 ft increments)

100-990 10.0...99.0 m (32.8...374.72 ft)1.0 m (3.28 ft increments)

c

Cable TypeCode Description

A64, B64, C64, F64 Pre-wired cables for Bulletin 1764 I/O base units

W64 I/O-ready cable for 1762-24AWA, and -24BWA base unit inputs

T64 I/O-ready cable for 1762-24AWA, -24BWA base units outputs

U64 I/O-ready cable for 1764-28BXB base unit outputs

Page 94: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

94

Publication 1769-SG002E-EN-P — January 2007

The cables used for Relay Master/Expander XIMs are the same as those used forDigital I/O Modules with the exception of the Cat. No. 1746-OA16 output module,which uses the 1492-CABLE*CR cable.

Important; The following AIFM Cat. No. breakdown is for explanation purposes only.It is not a product configurator. Not all combinations of fields are valid product cat.nos. Use this breakdown for verification and explanation only.

1492 – IFM 20 F-120 – 2a b c d

b

Digital Cable Connector SizeCode Description

20 20 pins

40 40 pins

c

Module Type (all types do not configure a catalog number)Code Description

A Input Module

F Feedthrough

F24 FuseD 24 Volt

F120 Fused 120 Volt

FS Fused Isolated

D LEDs

N Narrow

24 24 Volt

120 120 Volt

240 240 Volt

d

Number of Field Side Wiring TerminalsCode Description

Blank One per I/O connection (Standard Terminals)

2 Two per I/O connection (Extra Terminals)

3 Three per I/O connection (Sensor Terminals)

4 Four per I/O connection (Special Terminal)

a

IFM

DigitalInterfaceModules

RIFMDigitalInterfaceModules

Page 95: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

95

Publication 1769-SG002E-EN-P — January 2007

1492 – XIFM 20 24 – 16RF

a b c d

a Description

XIM Relay Interface Module with Fixed Terminal Block

RXIM Relay Interface Module with Removable Terminal BLock

b

No. Cable Connector PinsCode Description

20 20 pins

40 40 pins

Blank Expander module

c

Number of Field Side Wiring TerminalsCode Description

3 Three per I/O channel

5 Five per I/O channel

b

Module Type (all types do not configure a catalog number)Code Description

4 4 channel

C Combination

6 6 channel

8 8 channel

16 16 channel

F Fused

1492 – AIFM 16-F – 5

a b c

a

AIFM

AnalogInterfaceModule

RAIFMAnalogInterfaceModule

Page 96: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

96

Publication 1769-SG002E-EN-P — January 2007

c

Module Type (all types do not configure a catalog number)Code Description

F 24V relay coil

F-F24 5 x 20 mm fuse holders with 24 volt blown fuse indication

F-F120 5 x 20 mm fuse holders with 120V blown fuse indication D

24 24 volt relay coil

120 120 volt relay coil

d

No. Cable Connector PinsCode Description

2 2 terminals per point

8R 8 relays

16R 16 relays

16RF 16 fused relays

Page 97: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

97

Publication 1769-SG002E-EN-P — January 2007

b

Standard or Build to Order LengthsCode Description

005 0.5 m (1.64 ft)

Standard010 1.0 m (3.28 ft)

025 2.5 m (8.20 ft)

050 5.0 m (16.40 ft)

001…020 0.1…2.0 m (0.328…6.56 ft)0.1 m (0.328 ft increments)

Build-to-Order020…100 2.0…10.0 m (6.56…32.8 ft)

0.5 m (1.64 ft) increments

100…990 10.0…99.0 m (32.8…374.72 ft)1.0 m (3.28 ft) increments

a

Digital Interface Cable

1492 – CABLE 010 A

a b c

IFM and XIM Cable Cat. No. Explanationfor Digital I/O Modules

Important: Use the following tables as a product configurator for pre-wired, IFM-ready, and I/O module-ready cables for Bulletins 1746, 1756, and 1771 digital I/Omodule cables. All combinations of these fields make valid product cat. nos. Refer toselection tables for IFM/XIM compatibility and ordering.

Page 98: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

98

Publication 1769-SG002E-EN-P — January 2007

c

Cable TypeCode Description

A, B, C, D,E, G, N, S

Pre-wired cables for 8-point isolated and 16-point Bulletin 1746 I/O modules✶

CR Pre-wired cable for Cat. No. 1764-OA16 (XIM only)

F, T Pre-wired cable for digital Bulletin 1771 I/O modules�

FF Pre-wired cable with fused wiring arm for 16-point digital Bulletin 1771 output modules�

H Pre-wired cable for 32-point digital Bulletin 1746 I/O modules✶

J, K, L, M, R Pre-wired cables for 16-point isolated and 32-point digital Bulletin 1771 I/O modules�

U, V, W, X Pre-wired cable for 8- and 16-point digital Bulletin 1756 I/O modules‡

Y, Z Pre-wired cable for 16-point isolated and 32-point digital Bulletin 1756 I/O modules‡

P Digital IFM-ready cable with 20 conductors

Q Digital IFM-ready cable with 40 conductors

N3 Digital I/O module-ready cable with 40-point Cat. No. 1746-N3 cable connector

RTBB Digital I/O module-ready cable with 16-point Cat. No. 1746-RT25B terminal block (blue)

RTBO Digital I/O module-ready cable with 16-point Cat. No. 1746-RT25C terminal block (orange)

RTBR Digital I/O module-ready cable with 16-point Cat. No. 1746-RT25R terminal block (red)

TBCH Digital I/O module-ready cable with 36-pin Cat. No. 1746-TBCH removable terminal block

WA Digital I/O module-ready cable with Cat. No. 1771-WA 8-point wiring arm

WD Digital I/O module-ready cable with Cat. No. 1771-WD 6-point wiring arm

WH Digital I/O module-ready cable with Cat. No. 1771-WH 16-point wiring arm

WHF Digital I/O module-ready cable with Cat. No. 1771-WHF 16-point fused wiring arm

WN Digital I/O module-ready cable with Cat. No. 1771-WN 32-point wiring arm

✶ To make sure the Bulletin 1746 SLC 500 digital I/O module is compatible with IFM/XIM, refer to pages [BAD REF 158071 ],[BAD REF 158072 ], [BAD REF 158073 ], and [BAD REF 158074 ].� To make sure the Bulletin 1771 PLC digital I/O module is compatible with IFM/XIM, refer to pages [BAD REF 158076 ], [BAD

REF 158077 ], [BAD REF 158078 ], and [BAD REF 158079 ].‡ To make sure the Bulletin 1756 ControlLogix digital I/O module is compatible with IFM/XIM, refer to pages [BAD REF 158080

], [BAD REF 158081 ], [BAD REF 158082 ], and [BAD REF 158083 ].

Page 99: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

99

Publication 1769-SG002E-EN-P — January 2007

c

Cable TypeCode Description

A, B, C, D,E, G, N, S

Pre-wired cables for 8-point isolated and 16-point Bulletin 1746 I/O modules✶

CR Pre-wired cable for Cat. No. 1764-OA16 (XIM only)

F, T Pre-wired cable for digital Bulletin 1771 I/O modules�

FF Pre-wired cable with fused wiring arm for 16-point digital Bulletin 1771 output modules�

H Pre-wired cable for 32-point digital Bulletin 1746 I/O modules✶

J, K, L, M, R Pre-wired cables for 16-point isolated and 32-point digital Bulletin 1771 I/O modules�

U, V, W, X Pre-wired cable for 8- and 16-point digital Bulletin 1756 I/O modules‡

Y, Z Pre-wired cable for 16-point isolated and 32-point digital Bulletin 1756 I/O modules‡

P Digital IFM-ready cable with 20 conductors

Q Digital IFM-ready cable with 40 conductors

N3 Digital I/O module-ready cable with 40-point Cat. No. 1746-N3 cable connector

RTBB Digital I/O module-ready cable with 16-point Cat. No. 1746-RT25B terminal block (blue)

RTBO Digital I/O module-ready cable with 16-point Cat. No. 1746-RT25C terminal block (orange)

RTBR Digital I/O module-ready cable with 16-point Cat. No. 1746-RT25R terminal block (red)

TBCH Digital I/O module-ready cable with 36-pin Cat. No. 1746-TBCH removable terminal block

WA Digital I/O module-ready cable with Cat. No. 1771-WA 8-point wiring arm

WD Digital I/O module-ready cable with Cat. No. 1771-WD 6-point wiring arm

WH Digital I/O module-ready cable with Cat. No. 1771-WH 16-point wiring arm

WHF Digital I/O module-ready cable with Cat. No. 1771-WHF 16-point fused wiring arm

WN Digital I/O module-ready cable with Cat. No. 1771-WN 32-point wiring arm

✶ To make sure the Bulletin 1746 SLC 500 digital I/O module is compatible with IFM/XIM, refer to pages [BAD REF 158071 ],[BAD REF 158072 ], [BAD REF 158073 ], and [BAD REF 158074 ].� To make sure the Bulletin 1771 PLC digital I/O module is compatible with IFM/XIM, refer to pages [BAD REF 158076 ], [BAD

REF 158077 ], [BAD REF 158078 ], and [BAD REF 158079 ].‡ To make sure the Bulletin 1756 ControlLogix digital I/O module is compatible with IFM/XIM, refer to pages [BAD REF 158080

], [BAD REF 158081 ], [BAD REF 158082 ], and [BAD REF 158083 ].

Page 100: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

100

Publication 1769-SG002E-EN-P — January 2007

IFM and XIM Cable Cat. No. Explanationfor Digital I/O ModulesImportant: Use the following tables as a product configurator for pre-wired, IFM-ready, and I/O module-ready cables for Bulletins 1746, 1756, and 1771 digital I/Omodule cables. All combinations of these fields make valid product cat. nos. Refer toselection tables for IFM/XIM compatibility and ordering.

a

Digital Interface Cable

b

Standard or Build to Order LengthsCode Description

005 0.5 m (1.64 ft)

Standard010 1.0 m (3.28 ft)

025 2.5 m (8.20 ft)

050 5.0 m (16.40 ft)

001…020 0.1…2.0 m (0.328…6.56 ft)0.1 m (0.328 ft increments)

Build-to-Order020…100 2.0…10.0 m (6.56…32.8 ft)

0.5 m (1.64 ft) increments

100…990 10.0…99.0 m (32.8…374.72 ft)1.0 m (3.28 ft) increments

c

Cable TypeCode Description

A69, B69, C69,D69, E69, F69,G69, H69, J69,K69

Pre-wired cables for 8-, 16-, and 32-channelBulletin 1769 digital I/O modules

RTN18 I/O-ready cable with Cat. No. 1746-RTBN18terminal block

RTN10 I/O-ready cable with Cat. No. 1746-RTBN10terminal block

RTN32I Pre-wired for 32-channel 1769-IQ32

RTN320 Pre-wired for 32-channel 1769-OB32

1492 – CAB 010 Aa b c

Page 101: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

101

Publication 1769-SG002E-EN-P — January 2007

Pre-Wired Cable Cat. No. Explanation forBulletins 1746, 1756, and 1771 Analog I/OModules

Important: The following analog cable cat. no. breakdown is for explanationpurposes only. It is not a product configurator. All combinations of fields are not validproduct cat. nos. First, select the desired AIFM using the steps in Ordering Digital andAnalog Wiring Systems on page 23 of publication 1492-TD008AEN-P. Then, use thisbreakdown for verification and explanation only.

a

Analog Interface Cables

c

A-Cable TypeCode Description

A, B, C, D,L, Q

Pre-wired cables for Bulletin 1746 analog and RTD I/O modules.

E, F, G, H, J Pre-wired cables for Bulletin 1771 analog and RTD I/O modules.

TA, TB, TC,TD, UA, UB,UC, UD, VA,VB, WA, WB,X, Y, Z

Pre-wired cables for Bulletin 1756 analog, RTD, and thermocouple I/O modules.

YT Pre-wired cable for Bulletin 1756 thermocouple I/O modules.

M Pre-wired cables for Bulletin 1757 pulse input I/O modules

b

Standard or Build-to-Order Length CableCode Description

005 0.5 m (1.64 ft)

Standard010 1.0 m (3.28 ft)

025 2.5 m (8.20 ft)

050 5.0 m (16.40 ft)

001-020 0.1…2.0 m (0.328…6.56 ft)0.1 m (0.328 ft increments)

Build-to-Order020-100 2.0…10.0 m (6.56…32.8 ft)

0.5 m (1.64 ft) increments

100-990 10.0…99.0 m (32.8…374.72 ft)1.0 m (3.28 ft) increments

1492 – ACABLE 010 Aa b c

Page 102: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

102

Publication 1769-SG002E-EN-P — January 2007

Pre-Wired Cable Cat. No. Explanation forBulletin 1746 and 1769 Analog I/O Modules

Important: The following analog cable cat. no. breakdown is for explanationpurposes only. It is not a product configurator. All combinations of fields are not validproduct cat. nos. First, select the desired AIFM using the steps in Ordering Digital andAnalog Wiring Systems on page 23 of publication 1492-TD008AEN-P. Then, use thisbreakdown for verification and explanation only.

b

Standard or Build-to-Order Length CableCode Description

005 0.5 m (1.64 ft)

Standard010 1.0 m (3.28 ft)

025 2.5 m (8.20 ft)

050 5.0 m (16.40 ft)

001-020 0.1…2.0 m (0.328…6.56 ft)0.1 m (0.328 ft increments)

Build-to-Order020-100 2.0…10.0 m (6.56…32.8 ft)

0.5 m (1.64 ft) increments

100-990 10.0…99.0 m (32.8…374.72 ft)1.0 m (3.28 ft) increments

a

Analog Interface Cables

1492 – ACAB 005 A46a b c

c

Cable TypeCode Description

A46 Pre-wired cables for Bulletin 1746-NI16I and -NI16V analog modules.

AA69, AB69,BA69, BB69,BC69, BD69,C69, D69,EA69, EB69,EC69, ED69

Pre-wired cables for Bulletin 1769 analog I/O modules.

Page 103: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

103

Publication 1769-SG002E-EN-P — January 2007

Selecting a Wiring SystemSelection Tables

Use of Selection Tables

� Locate I/O Module required. The top row indicates the I/O module for the I/OPlatform

� Locate the Interface Module required. The second and third column indicates theInterface Module Catalog number

� Determine if Interface Module exists for the I/O module. Indicated by “Letter Code”in row (Interface Catalog Number) and the column (I/O Module)

� Locate Cable. This is the letter indicated by “Letter Code” in the row (InterfaceCatalog Number) and the column (I/O Module). The “Letter Code” represents thesuffix of the Pre-Wired Cable

� Determine Cable Catalog Number. Add 1492-CABLE_ _ _”Letter Code”, example1492-CABLE_ _ _A

� Determine length of cable required, Standard Lengths are 0.5 m, 1.0 m, 2.5 m and5.0 m; which represents 005, 010, 025 and 050 for _ _ _ in the cable catalognumber. Example 1492-CABLE010A = a 1.0 m cable with “Letter Code” A

Page 104: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

104

Publication 1769-SG002E-EN-P — January 2007

1769 Digital I/O ModuleSelectionBulletin 1769 Compact I/O for CompactLogixand MicroLogix 1500 IFMs and Cables

Bulletin 1769 Digital 8 and 16-Point I/O Modules ‡

Description of 20-Pin IFM

Catalog Number forWiring System Modulewith Fixed Terminal Block

Catalog Number for WiringSystem Module withRemovable Terminal BlockSocket Assembly (orderplugs separately)

I/O Module Cat. No. 1769-…

IA8I

IA16

IQ16

IQ16F

IM12

OA8

OA16

OB8

OB16

OV16

OW8

OW8I

OW16

Feed-through

Standard 264V AC/DC Max. 1492-IFM20F 1492-RIFM20F� F69 A69 B69 B69 G69 C69 M69 L69 E69 E69 C69 D69 M69

Narrow standard 132V AC/DC Max. 1492-IFM20FN 1492-RIFM20FN� F69 A69 B69 B69 — C69 M69 L69 E69 E69 C69 ⎯ M69

Extra terminals (2 per I/O) 264V AC/DC Max. 1492-IFM20F-2 1492-RIFM20F-2� ⎯ A69 B69 B69 G69 C69 M69 L69 E69 E69 C69 ⎯ M69

3-wire sensor type input devices 132V AC/DC Max. 1492-IFM20F-3 ⎯ ⎯ A69 B69 B69 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯LED Indicating

Standard with 24V AC/DC LEDs 1492-IFM20D24 ⎯ ⎯ ⎯ B69 B69 ⎯ ⎯ ⎯ ⎯ E69 E69 ⎯ ⎯ M69

Narrow standard with 24V AC/DC LEDs 1492-IFM20D24N ⎯ ⎯ ⎯ B69 B69 ⎯ ⎯ ⎯ ⎯ E69 ⎯ ⎯ ⎯ H69

Standard with 120V AC/DC LEDs 1492-IFM20D120§ ⎯ ⎯ A69 ⎯ ⎯ ⎯ ⎯ M69 ⎯ ⎯ ⎯ ⎯ ⎯ M69

Narrow standard with 120V AC LEDs 1492-IFM20D120N ⎯ ⎯ A69 ⎯ ⎯ ⎯ ⎯ H69 ⎯ ⎯ ⎯ ⎯ ⎯ H69

24V AC/DC LEDs and extra terminals for outputs 1492-IFM20D24-2 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ E69 E69 ⎯ ⎯ M69

24V AC/DC LEDs and extra terminals for inputs 1492-IFM20D24A-2 ⎯ ⎯ ⎯ B69 B69 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯120V AC LEDs and extra terminals for outputs 1492-IFM20D120-2 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ M69 ⎯ ⎯ ⎯ ⎯ ⎯ M69

120V AC LEDs and extra terminals for inputs 1492-IFM20D120A-2 ⎯ ⎯ A69 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯3-wire sensor with 24V AC/DC LEDs 1492-IFM20D24-3 ⎯ ⎯ ⎯ B69 B69 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯8 Individually isolated with 24/48V AC/DC LEDs and4 terminals/output 1492-IFM20DS24-4 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ C69 D69 ⎯

8 Individually isolated with 120V AC LEDs and 4terminals/output 1492-IFM20DS120-4 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ C69 ⎯ ⎯ ⎯ ⎯ C69 D69 ⎯

240V AC LEDs and extra terminals for outputs 1492-IFM20D240-2 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ M69 ⎯ ⎯ ⎯ ⎯ ⎯ M69

240V AC LEDs and extra terminals for inputs 1492-IFM20D240A-2 ⎯ ⎯ ⎯ ⎯ ⎯ G69 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯Fusible

120V AC/DC with extra terminals for outputs 1492-IFM20F-F-2 1492-RIFM20F-F-2� ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ M69 ⎯ E69 E69 ⎯ ⎯ M69

Extra terminals with 24V AC/DC blown fuse LEDindicators 1492-IFM20F-F24-2 1492-RIFM20F-F24-2� ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ E69 E69 ⎯ ⎯ M69

Extra terminals with 120V AC/DC blown fuse LEDindicators 1492-IFM20F-F120-2 1492-RIFM20F-F120-2� ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ M69 ⎯ ⎯ ⎯ ⎯ ⎯ M69

Extra terminals with 240V AC/DC blown fuse LEDindicators 1492-IFM20F-F240-2 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯

Extra terminals with 24V AC/DC blown fuse LEDindicators for inputs 1492-IFM20F-F24A-2 1492-RIFM20F-F24A-2� ⎯ ⎯ B69✶ B69✶ ⎯ ⎯ ⎯ ⎯ ⎯ E69 ⎯ ⎯ ⎯

Extra terminals with 120V AC/DC blown fuse LEDindicators for inputs 1492-IFM20F-F120A-2 1492-RIFM20F-F120A-2� ⎯ A69 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯

8 Individually isolated 120V AC/DC with extra ter-minals for outputs 1492-IFM20F-FS-2 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ C69 ⎯ ⎯ ⎯ ⎯ C69 D69 ⎯

8 Individually isolated with extra terminals and 24VAC/DC blown fuse LED indicators 1492-IFM20F-FS24-2 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ C69 D69 ⎯

Page 105: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

105

Publication 1769-SG002E-EN-P — January 2007

Description of 20-Pin IFM

Catalog Number forWiring System Modulewith Fixed Terminal Block

Catalog Number for WiringSystem Module withRemovable Terminal BlockSocket Assembly (orderplugs separately)

I/O Module Cat. No. 1769-…

IA8I

IA16

IQ16

IQ16F

IM12

OA8

OA16

OB8

OB16

OV16

OW8

OW8I

OW16

Fusible

Two 4-point isolated groups with fourterminals/input and 24V AC/DC blown fuse LEDindicators

1492-IFM20F-FS24A-4 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯

8 Individually isolated with extra terminals/outputand 120V AC/DC blown fuse LED indicators 1492-IFM20F-FS120-2 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ C69 ⎯ ⎯ ⎯ ⎯ C69 D69 ⎯

8 Individually isolated with 4 terminals/output and120V AC/DC blown fuse LED indicators 1492-IFM20F-FS120-4 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ C69 ⎯ ⎯ ⎯ ⎯ C69 D69 ⎯

Two 4-point isolated groups with fourterminals/input and 120V AC/DC blown fuse indi-cators

1492-IFM20F-FS120A-4 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯

8 Individually isolated with 4 terminals/output and240V AC/DC blown fuse LED indicators 1492-IFM20F-FS240-4 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ D69 ⎯

Relay Master (LED Indicating)♣➤

20-pin master with eight (8) 24V DC relays 1492-XIM2024-8R ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ E69 ⎯ ⎯ ⎯ ⎯20-pin master with eight (8) 120V AC relays 1492-XIM20120-8R ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ H69 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯20-pin master with sixteen (16) 24V DC relays 1492-XIM2024-16R ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ E69 ⎯ ⎯ ⎯ ⎯20-pin master with sixteen (16) 24V DC relays withfusing 1492-XIM2024-16RF ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ E69 ⎯ ⎯ ⎯ ⎯

20-pin master with sixteen (16) 120V AC relays 1492-XIM20120-16R ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ H69 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯20-pin master with sixteen (16) 120V AC relayswith fusing 1492-XIM20120-16RF ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ H69 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯

Relay Expander (LED Indicating)♣➤

Expander with eight (8) 24V DC relays 1492-XIM24-8R ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ � ⎯ ⎯ ⎯ ⎯Expander with eight (8) 120V AC relays 1492-XIM120-8R ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯Fusible Expander

8-channel expander with 24V DC blown fuse indi-cators 1492-XIMF-F24-2 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ � ⎯ ⎯ ⎯ ⎯

8-channel expander with 120V AC blown fuse indi-cators 1492-XIMF-F120-2 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ � ⎯ ⎯ ⎯ ⎯ ⎯ ⎯

Feed-through Expander

Expander with eight (8) feed-through channels132V AC/DC max 1492-XIMF-2 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ � � ⎯ ⎯ ⎯ ⎯

✶In the input module's sink mode only.

�One expander module is connected to a master to provide a total of 16 outputs. An extender cable is included with each expander to connect it to the master.

‡Cables are available in standard length of 0.5 m, 1.0 m, and 5.0 m. To order, insert the code for the desired cable length into the catalog number 005 = 0.5 m (010 = 1.0 m, 025 = 2.5 m, and050 = 5.0 m), and insert the letter in the box. Example: CCaattaalloogg NNuummbbeerr 11440022--CCAALLBBEE005500AA is for a 5.0 m cable, and the letter A.

Page 106: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

106

Publication 1769-SG002E-EN-P — January 2007

♣The voltage rating is relay control/coil voltage. For relay contact ratings, refer to [T-3900680]

Description of 20-Pin IFM

Catalog Number forWiring System Modulewith Fixed Terminal Block

Catalog Number for WiringSystem Module withRemovable Terminal BlockSocket Assembly (orderplugs separately)

I/O Module Cat. No. 1769-…

IA8I

IA16

IQ16

IQ16F

IM12

OA8

OA16

OB8

OB16

OV16

OW8

OW8I

OW16

Feed-through Expander

§This IFM is not recommended for use the PLC I/O modules that have an off-state leadkage current exceeding 0.5 mA. Use a 1492-IFM20D120N or 1492-IFM20D120A-2 for inputs. Use 1492-IFM20D120-2 for outputs.

➤The LED indicates the PLC output status.

�Compatible Removable Terminal Block (RTB) plug 1492-RTB20N (screw style terminal) or 1492-RTB20P (push-in style terminal, available June 2007). Order plugs separately.

� Compatible Removable Terminal Block (RTB) plug 1492-RTB10N (screw style terminal) or 1492-RTB10P (push-in style terminal, available June 2007). Order plugs separately.

Page 107: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

107

Publication 1769-SG002E-EN-P — January 2007

Bulletin 1769, Continued/New XIM’s for1746, 1756, 1769, and 1771

Bulletin 1769 Digital 32-Point I/O Modules ✶

Description of 40-Pin IFM

Catalog Number for WiringSystem Module with FixedTerminal Block

Catalog umber for WiringSystem Module withRemovable Terminal BlockSocket Assembly (order plugsseparately)

I/O Module Cat. No. 1769-…

IQ32

OB32

Feed-through

Standard 132V AC/DC Max. 1492-IFM40F 1492-RIFM40F➤ J69 K69

Extra terminals (2 per I/O) 132V AC/DC Max. 1492-IFM40F-2 1492-RIFM40F-2➤ J69 K69

3-wire sensor type input devices 60V AC/DC Max. 1492-IFM40F-3 — J69 —

LED Indicating

Standard with 24V AC/DC LEDs 1492-IFM40D24 1492-RIFM40D24➤ J69 K69

24V AC/DC LEDs and extra terminals for outputs 1492-IFM40D24-2 — — K69

24V AC/DC LEDs and extra terminals for inputs 1492-IFM40D24A-2 1492-RIFM40D24A-2➤ J69 —

120V AC LEDs and extra terminals for outputs 1492-IFM40D120-2 — — —

120V AC LEDs and extra terminals for inputs 1492-IFM40D120A-2 — — —

3-wire sensor with 24V AC/DC LEDs 1492-IFM40D24-3 — J69 —

16 Individually isolated with 24/48V AC/DC LEDs and four terminals/output 1492-IFM40DS24-4 — — —

16 Individually isolated with 24V AC/DC LEDs and four terminals/input 1492-IFM40DS24A-4 — — —

16 Individually isolated with 120V AC LEDs and four terminals/output 1492-IFM40DS120-4 — — —

16 Individually isolated with 120V AC LEDs and four terminals/input 1492-IFM40DS120A-4 — — —

16 Individually isolated with 240V AC LEDs and four terminals/input 1492-IFM40DS240A-4 — — —

Fusible

120V AC/DC with extra terminals for outputs 1492-IFM40F-F-2 — — K69

Extra terminals with 24V AC/DC blown fuse indicators for outputs 1492-IFM40F-F24-2 1492-RIFM40F-F24-2➤ — K69

Extra terminals with 120V AC/DC blown fuse indicators for outputs 1492-IFM40F-F120-2 — — —

16 Individually isolated with extra terminals for 120V AC/DC outputs 1492-IFM40F-FS-2 — — —

16 individually isolated with extra terminals and 24V AC/DC blown fuse indicators 1492-IFM40F-FS24-2 — — —

16 Individually isolated with 24V AC/DC blown fuse indicators and four terminals/output 1492-IFM40F-FS24-4 — — —

16 Individually isolated 240V AC/DC with four terminals/output 1492-IFM40F-FS-4 — — —

16 Individually isolated with extra terminals and 120V AC/DC blown fuse LED indicators 1492-IFM40F-FS120-2 1492-RIFM40F-FS120-2➤ — —

16 Individually isolated with 120V AC/DC blown fuse indicators and four terminals/output 1492-IFM40F-FS120-4 1492-RIFM40F-FS120-4� — —

16 Individually isolated with 240V AC/DC blown fuse indicators and four terminals/output 1492-IFM40F-FS240-4 — — —

16 Individually isolated with 24V AC/DC blown fuse indicators and four terminals/input 1492-IFM40F-FS24A-4 — — —

16 Individually isolated with 120V AC/DC with four terminals/input 1492-IFM40F-FSA-4 — — —

16 Individually isolated with 120V AC/DC blown fuse indicators and four terminals/input 1492-IFM40F-FS120A-4 1492-RIFM40F-FS120A-4� — —

16 Individually isolated with 240V AC/DC blown fuse indicators and four terminals/input 1492-IFM40F-FS240A-4 — — —

Relay Master (LED Indicating)§♣

40-pin master with eight (8) 24V DC relays 1492-XIM4024-8R — — K69

Page 108: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

108

Publication 1769-SG002E-EN-P — January 2007

40-pin master with sixteen (16) 24V DC relays 1492-XIM4024-16R 1492-RXIM4024-16R� — K69

40-pin master with sixteen (16) 24V DC relays with fusing 1492-XIM4024-16RF — — K69

Relay Expander (LED Indicating)§♣

Expander with eight (8) 24V DC relays 1492-XIM24-8R 1492-RXIM24-8R� — �

Expander with eight (8) 120V AC relays 1492-XIM120-8R — — —

Fusible Expander

8-channel expander with 24V DC blown fuse indicators 1492-XIMF-F24-2 — — �

8-channel expander with 120V AC blown fuse indicators 1492-XIMF-F120-2 — — —

Expander with sixteen (16) 24V DC relays with fusing 1492-XIM24-16RF — — ‡

Feed-through Expander

Expander with eight (8) feed-through channels 132V AC/DC max 1492-XIMF-2 — — �

✶Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the catalog number, i.e., 005 = 0.5 m (010 = 1.0 m, 025= 2.5 m, and 050 = 5.0 m), and insert the letter in the box. Example: CCaattaalloogg NNuummbbeerr 11449922--CCAABBLLEE005500AA is for a 5.0 m cable, and the letter A.�Can have up to 2 or 3 expander modules depending upon master used (total 32 outputs or less). An extender cable is provided.‡The 1492-XIM24-16RF is to be used with one 1492-XIM4024-16R or 1492-XIM4024-16RF master (32 pts. max.).♣The LED indicates the PLC output status.➤ Compatible Removable Terminal Block (RTB) plug; 1492-RTB20N (screw style terminal) or 1492-RTB20P (push-in style terminal, available June 2007). ORDER PLUGS SEPARATELY.� Compatible Removable Terminal Block (RTB) plug; 1492-RTB17N (screw style terminal) or 1492-RTB17P (push-in style terminal, available June 2007). ORDER PLUGS SEPARATELY.� Compatible Removable Terminal Block (RTB) plug; 1492-RTB14N (screw style terminal) or 1492-RTB14P (push-in style terminal, available June 2007). ORDER PLUGS SEPARATELY.� Compatible Removable Terminal Block (RTB) plug; 1492-RTB12N (screw style terminal) or 1492-RTB12P (push-in style terminal, available June 2007). ORDER PLUGS SEPARATELY.

Relay Master (LED Indicating)§♣

IQ32

OB32Description of 40-Pin IFM

Catalog Number for WiringSystem Module with FixedTerminal Block

Catalog umber for WiringSystem Module withRemovable Terminal BlockSocket Assembly (order plugsseparately)

I/O Module Cat. No. 1769-…

§The voltage rating is relay contro/coil voltage. For relay contact ratings, refer to [S-3900681]

Page 109: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

109

Publication 1769-SG002E-EN-P — January 2007

Bulletin 1769 Compact I/O for CompactLogix andMicroLogix 1500 IFMs and Cables

These pre-wired cables have a pre-wired RTB on one end to connect to the front ofa Bulletin 1769 digital I/O module and a connector on the other end to plug into a20-terminal IFM/XIM. You must first select the IFM/XIM from the preceding selectiontable.

The I/O module-ready cables have a pre-wired RTB on one end to plug onto thefront of a Bulletin 1769 I/O module and 20 individually colored #18 AWG conductorson the other end. These cables provide the convenience of pre-wired connections atthe I/O module end, while still allowing the flexibility to fieldwire to standard terminalblocks of your choice.

Cable Cat. No.Standard CableLengths

Build-to-OrderAvailable No. of Conductors Mating 1746 I/O Module Cat. No.

1492-CAB✶A69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-IA16

1492-CAB✶B69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-IQ16

1492-CAB✶C69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-OA8, -OW8

1492-CAB✶D69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-OW8I

1492-CAB✶E69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-OB16, -OV16

1492-CAB✶F69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-IA8I

1492-CAB✶G69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-IM12

1492-CAB✶H69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-OA16, -OW16 (IFM modules with single common)

1492-CAB✶J69 0.5, 1.0, 2.5, 5.0 m Yes 40 1769-IQ32

1492-CAB✶K69 0.5, 1.0, 2.5, 5.0 m Yes 40 1769-OB32

1492-CAB✶L69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-OB8

1492-CAB✶M69 0.5, 1.0, 2.5, 5.0 m Yes 20 1769-OA16, -OW16 (IFM modules with multiple commons)

✶Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and050 = 5.0 m). Example: CCaatt.. NNoo.. 11449922--CCAABB000055EE6699 is for a 0.5 m cable that can be used to connect a Cat. No. 1492-IFM20D24N IFM to a Cat. No. 1769-OB16 I/O module.

I/O Module-Ready Cables for Bulletin 1769 DigitalI/O Modules §

Cable Cat. No.Standard CableLengths Build-to-Order Available No. of Conductors Mating 1746 I/O Module Cat. No.

1492-CAB�RTN10 1.0, 2.5, 5.0 m Yes 12 1769-OA8, -OW8, -OB8

1492-CAB�RTN181.0, 2.5, 5.0 m

Yes 201769-IA8I, -IA16, -IQ16, IQ16F, -OA16, -OB16, -OV16, -OW16, -OW8I, -IM12, -OW16,-0B8

1492-CAB�RTN32I 1.0, 2.5, 5.0 m Yes 40‡ 1769-IQ32

1492-CAB�RTN32O 1.0, 2.5, 5.0 m Yes 40‡ 1769-OB32

�Cables are available in standard lengths of 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m).Example: CCaatt.. NNoo.. 11449922--CCAABB005500RRTTNN1100 is for a 5.0 m cable with a wired Cat. No. 1746-RTBN10 on one end.

‡1492-CAB�RTN32I and 1492-CAB�RTN32O cables use 22 AWG wire.§Discrete I/O ready cables should not be used with PLC analog I/O modules as a cable shield and drain wire are not provided.

Page 110: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

110

Publication 1769-SG002E-EN-P — January 2007

1769 Analog I/O ModuleSelectionBulletin 1769 Compact I/O forCompactLogix and MicroLogix 1500AIFMs and Cables

IFMs for Bulletin 1769 Analog I/O Modules✶

Page 111: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

111

Publication 1769-SG002E-EN-P — January 2007

Description

Catalog Number forWiring SystemModule with FixedTemrinal Block

Catalog Number forWiring SystemModule withRemovable TerminalBlock SocketAssembly (orderplugs separately)

I/O Module Cat. No. 1769-…

HSC

IF4(Single-EndedVoltage)

IF8(Single-EndedVoltage)

IF4(Single-EndedCurrent)

IF8(Single-EndedCurrent)

IF4(DifferentialVoltage)

IF8(DifferentialVoltage)

IF4(DifferentialCurrent)

IF8(DifferentialCurrent) IR6

OF2(Voltage)

OF8V(Voltage)

OF2(Current)

OF8C(Current)

Feed-through

4-channelinput, outputor 2-in/2-outcombinationwith 3terminals/channel

1492-AIFM4-3 1492-RAIFM4-3‡ — BA69 — BB69 — BC69 — BD69 — — AA69 — AB69 —

6-channelisolated with3…4terminals/channel

1492-AIFM6S-3 1492-RAIFM6S-3§ — — — — — — — — — C69 — — — —

8-channeldifferential16-channelsingle-endedwith 3terminals/channel

1492-AIFM8-3 1492-RAIFM8-3♣ — — EA69 — EB69 — EC69 — ED69 — — D69 — D69

Thermocouple

6-channelwith 3terminals/channel

1492-AIFM6TC-3 — — — — — — — — — — — — — — —

High-Speed Counter/Encoder

2-channelcounterinput/4outputs

1492-AIFMCE4 — HA69 — — — — — — — — — — — — —

Fused High-Speed Counter/Encoder

2-channelfused counterinput/4 fusedoutputs

1492-AIFMCE4-F — HA69 — — — — — — — — — — — — —

Fusible

4-channelwith 24Vblown fuseindicators, test points, 5 terminals/input

1492-AIFM4I-F-5 — — BA69 — BB69 — BC69 — BD69 — — — — — —

2-channeloutput, 2-channel inputwith 24Vblown fuseindicators, test points, 5 terminals/input, 3 terminals/output

1492-AIFM4C-F-5 — — — — — — — — — — — — — — —

8-channelwith 24V DCblown fuseindicators, 5 terminals/channel

1492-AIFM8-F-5 — — — EA69 — EB69 — EC69 — ED69 — — — — —

Page 112: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

112

Publication 1769-SG002E-EN-P — January 2007

Description

Catalog Number forWiring SystemModule with FixedTemrinal Block

Catalog Number forWiring SystemModule withRemovable TerminalBlock SocketAssembly (orderplugs separately)

I/O Module Cat. No. 1769-…

HSC

IF4(Single-EndedVoltage)

IF8(Single-EndedVoltage)

IF4(Single-EndedCurrent)

IF8(Single-EndedCurrent)

IF4(DifferentialVoltage)

IF8(DifferentialVoltage)

IF4(DifferentialCurrent)

IF8(DifferentialCurrent) IR6

OF2(Voltage)

OF8V(Voltage)

OF2(Current)

OF8C(Current)

Fusible16-channelinput with 24VDC blown fuseindicators, 3terminals/channel

1492-AIFM16-F-3 — — — — — — — — — — — — — — —

16-channelinput with 24VDC blown fuseinidcators, 5terminals/channel

1492-AIFM16-F-5 — — — — — — — — — — — — — — —

16-channelinput with 24VDC blown fuseinidcators, 5terminals/channel

1492-AIFMQS — — — — — — — — — — — — — — —

✶Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the catalog number, i.e., 005 = 0.5 m (010 = 1.0 m, 025 =

‡ Compatible Removable Terminal Block (RTB) plug 1492-RTB8N (screw style terminal) or 1492-RTB8P (push-in style terminal, available June 2007). Order plugs separately.§ Compatible Removable Terminal Block (RTB) plug 1492-RTB12N (screw style terminal) or 1492-RTB12P (push-in style terminal, available June 2007). Order plugs separately.♣ Compatible Removable Terminal Block (RTB) plug 1492-RTB16N (screw style terminal) or 1492-RTB16P (push-in style terminal, available June 2007). Order plugs separately.

Page 113: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

113

Publication 1769-SG002E-EN-P — January 2007

These pre-wired cables have a pre-wired RTB on one end to connect to the front ofa Bulletin 1769 analog I/O module and a connector on the other end to plug into a20-terminal AIFM. You must first select the AIFM from the preceding selection table.

Pre-Wired Cables for Bulletin 1769 Analog I/OModules

Cable Cat. No. Size Build-to-Order Available Type of IFM/AIFM/XIM Mating I/O Module Cat. No.

1492-ACAB✶AA69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-OF2 Voltage

1492-ACAB✶AB69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-OF2 Current

1492-ACAB✶BA69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-IF4 Single-Ended Voltage

1492-ACAB✶BB69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-IF4 Single-Ended Current

1492-ACAB✶BC69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-IF4 Differential Voltage

1492-ACAB✶BD69 0.5, 1.0, 2.5, 5.0 m Yes 15-pin D-shell 1769-IF4 Differential Current

1492-ACAB✶C69 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1769-IR6

1492-ACAB✶D69 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1769-OF8C, 1769-OF8V

1492-ACAB✶EA69 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1769-IF8 Single-Ended Voltage

1492-ACAB✶EB69 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1769-IF8 Single-Ended Current

1492-ACAB✶EC69 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1769-IF8 Differential Voltage

1492-ACAB✶ED69 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1769-IF8 Differential Current

1492-ACAB✶HA69 0.5, 1.0, 2.5, 5.0 m Yes 25-pin D-shell 1769-HSC Counter/Encoder

✶Cables are available in standard lengths of 0.5 m, 1.0 m, 2.5 m, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and050 = 5.0 m). Example: CCaatt.. NNoo.. 11449922--AACCAABB000055AAAA6699 is for a 0.5 m cable that connects a 1492-AIFM4-3 to a 1769-OF2 analog output in voltage mode.

Page 114: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

114

Publication 1769-SG002E-EN-P — January 2007

Step 3 - Select:

The 1769 Compact I/O modules can be used with a:

Selecting a Control Interface� one of these control interfaces

- 1768 CompactLogix controller- 1769 CompactLogix controller- 1764 MicroLogix 1500 controller- 1769-ADN DeviceNet adapter

� 1768 CompactLogix controller.

� 1769 CompactLogix controller.

� 1764 MicroLogix 1500 controller assembly.

� 1769-ADN DeviceNet I/O adapter.

Available 1768 Controllers

Cat. No.Available UserMemory (KB)✶

NonvolatileMemory

CommunicationPorts

BackplaneCurrent (mA) at5V

BackplaneCurrent (mA) at24V

BackplaneCurrent Output

PowerDissipation Capacity

I/O BanksSupported, Max.

1768-L43 2 MB64 MBCompactFlash

1 RS-232 port 0 A 1.3 A

1768 backplane• 2.8 A @ 5.2V

1769 backplane• 2.0 A @ 5.2V• 1.0 A @ 24V

6.3 W• two 1768modules• 16 1769 modules

3

CCeerrttiiffiiccaattiioonnss:: UL, CSA (Class I, Division 2, Group A, B, C, D), CE, C-TickSee the Product Certifications link at http://ab.com for Declarations of Conformity, Certifications, and other certifications details.✶Available user memory is the amount of memory available to the user after RSLogix 5000 Enterprise Series software is connected and a null program is loaded.

Page 115: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

115

Publication 1769-SG002E-EN-P — January 2007

Available 1769 Controllers

Cat. No.

AvailableUser Memory(Kbytes)✶

NonvolatileMemory��

Number ofConcurrentTasks

CommunicationPorts

BackplaneCurrent (mA)at 5V

BackplaneCurrent (mA)at 24V

PowerDissipation

I/O ModuleCapacity

I/O BanksSupported,Max.

Power SupplyDistanceRating

1769-L35E 1536 K bytes64 MbytesCompactFlash

8

1 RS-232 port:38.4 kbps max(DF1)1 EtherNet/IPport: 10/100Mbps (RJ-45 or10BaseT)

660 mA 90 mA 4.74 W 30 3 4 modules

1769-L35CR 1536 K bytes64 MbytesCompactFlash

8RS-232, NAP,ControlNetchannels A and B

680 mA 40 mA 4.36 W 30 3 4 modules

1769-L32E 768 K bytes64 MbytesCompactFlash

6

1 RS-232 port:38.4 kbps max(DF1)1 EtherNet/IPport: 10/100Mbps (RJ-45 or10BaseT)

660 mA 90 mA 4.74 W 16 3 4 modules

1769-L32C 768 K bytes64 MbytesCompactFlash

6RS-232, NAP,ControlNetchannel A

680 mA 40 mA 4.36 W 16 3 4 modules

1769-L31 512 K bytes64 MbytesCompactFlash

4

CH0 - RS-232DF1, DH-485,ASCIIfully isolated38.4 kbps max

CH1 - RS-232DF1, DH-485,ASCIInon-isolated38.4 kbps max

330 mA 40 mA 2.61 W 16 3 4 modules

CCeerrttiiffiiccaattiioonnss:: UL, CSA (Class I, Division 2, Group A, B, C, D), CE, C-TickSee the Product Certifications link at http://ab.com for Declarations of Conformity, Certifications, and other certifications details.

✶Available user memory is the amount of memory available to the user after RSLogix 5000 Enterprise Series software is connected and a null program is loaded.�Requires a 1784-CF64 Industrial CompactFlash card.

Page 116: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

116

Publication 1769-SG002E-EN-P — January 2007

Select Expansion Cables

How you orient I/O banks determines which expansion cables you need to connectthe I/O banks.

If you add a And connect the chassis Use this cable✶

Second bankRight to left 1769-CRLxRight to right 1769-CRRx

Third bankRight to left 1769-CRLxRight to right 1769CRRxLeft to left 1769-CLLx

✶Where x = 1 for 1 ft (305 mm) or 3 for 3.28 ft (1 m).

Page 117: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

117

Publication 1769-SG002E-EN-P — January 2007

Use the 1764 MicroLogix 1500 packaged controller when the Compact I/O system isthe modular expansion I/O (8 modules maximum) for the base I/O. You can have upto 16 modules when you use the MicroLogix 1500 Series C processor with a Series Bbase and RSLogix 500 software, version 5.0 or later.

You can use a 1769 power supply if the power capacity of the embedded MicroLogix1500 power supply is insufficient to drive all the I/O modules in the system.

A maximum of one 1769 power supply and one communication cable can be used ina MicroLogix 1500 system, allowing for two banks of I/O modules (one connecteddirectly to the controller, and the other connected via the cable). The local bank(bank 0, which includes the controller) supports eight modules and the expansionbank supports eight modules, for a maximum total of sixteen I/O modules in onesystem. Each I/O bank requires its own power supply (bank 0 uses the controller’sembedded power supply.

Important: The expansion power supply cannot be connected directly to a controllerthat has an embedded power supply, such as the MicroLogix 1500 controller. It mustbe connected using one of the expansion cables. Only one power supply (embeddedor expansion) may be used on an I/O bank. Exceeding these limitations may damagethe power supply and result in unexpected operation.

Checking the MicroLogix Firmware Revision

MicroLogix 1500 Packaged Controllers

Important: If your processor is at an older revision, you must upgrade the operatingsystem to FRN 3 or later to use an expansion cable and power supply. On the Internet,go to:

http://www.ab.com/plclogic/prodinfo/plcweb/products/mlogix/ABMicroIndex.html

to download the operating system upgrade. Type MicroLogix 1500 and go to Tools andTips.

To use a MicroLogix 1500 controller with a 1769 expansion I/O power supply, verifythat you have the following:

� MicroLogix 1500 processor, catalog number 1764-LSP, series A, revision C and later

� Operating system version: firmware revision number (FRN) 3 and later

You can check the FRN by looking at word S: 59 (operating-system firmware revisionnumber) in the status file.

Page 118: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

118

Publication 1769-SG002E-EN-P — January 2007

Selecting Expansion Cables

The following illustrations provide examples of vertical and horizontal systemexpansion of the MicroLogix 1500 controller using the Compact I/O system.

Page 119: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

119

Publication 1769-SG002E-EN-P — January 2007

Category Guidelines

Capacity

� The 1769-ADN adapter can communicate with up to 30 Compact I/O modules on a singleDeviceNet node.

� You can have a maximum of three banks of I/O connected with up to two communicationexpansion cables.

� The adapter supports a total of:

180 words of input data from the I/O modules.

180 words of output data to the I/O modules.

724 words of configuration data for the I/O modules.

� A typical 16 point input module uses one input word, and a typical 16 point output moduleuses one input and output word.

Configuration

� The adapter must be the first and leftmost module in the system (the first module of bank 1).

� I/O banks must be connected using a bus communication cable (for example, 1769-CRL1).

� Each bank of I/O must have its own power supply.

� Each module type has its own distance rating (the number of modules from the powersupply). Each module must be within its distance rating. The 1769-ADN adapter has a distancerating of four, therefore the adapter must be within four modules of the power supply.

� I/O modules are not required between either the adapter and an end cap or between thepower supply and an end cap.

� An end cap terminator (for example, 1769-ECR or 1769-ECL) must be used on the last I/Obank.

� Address slots contiguously left-to-right within each bank. Power supplies, cables, and end capsdo not use an address.

� A bank of I/O can have a maximum of 16 modules with a maximum of eight on either side ofthe power supply, depending upon module loading of the power supply. The maximum amountof current each bank supports in one direction (either side of the power supply) is 2 A at 5Vdc and 1 A at 24V dc.

1769-ADN DeviceNet Adapter Module

Use the 1769-ADN DeviceNet adapter module when the Compact I/O system is theprimary I/O for the adapter (30 modules maximum). The 1769-ADN adapter allowsthe 1769 Compact I/O system to be used with a DeviceNet Master.

Page 120: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

120

Publication 1769-SG002E-EN-P — January 2007

Example Configurations

The 1769-ADN adapter is always the leftmost module of bank one. The 1769-ADNadapter can interface with up to 30 Compact I/O modules on a single DeviceNet node.The number of I/O modules cannot exceed 16 on a single bank.

Page 121: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

121

Publication 1769-SG002E-EN-P — January 2007

Step 4 - Select:

� if power consumption exceeds themaximum for a single power supply,install additional banks and powersupplies

Selecting Power Supplies

Compact I/O power supplies distribute power from either side of the power supply.For example, a 2 A at 5V dc power supply (1769-PA2, 1769-PB2) can provide 1 A tothe right side of the power supply and 1 A to the left. A 4 A at 5V dc power supply(1769-PA4, 1769-PB4) can provide 2 A to the right side of the power supply and 2 Ato the left.

1769 Power Supplies

1769 I/O Power SuppliesEach additional bank of I/O modules requires a 1769 power supply. Place 1769 I/Omodules to the left or the right of the 1769 power supply. As many as eight I/Omodules can be placed on each side of the power supply.

Each 1769 module also has a power supply distance rating (the number of modulesfrom the power supply). Each module must be located within its distance rating. Seethe specifications for the module to determine its distance rating.

Cat. No. DescriptionOperatingVoltage Range

PowerConsumption,Max. Current Capacity

24V dc UserPower Capacity(0° to 55°C)

Inrush Current,Max.

Line Loss RideThrough

OvervoltageProtection

Power SupplyDistance Rating

1769-PA2Compact 124/240Vac ExpansionPower Supply

85…265V ac(wide range; nojumper or DIPswitch required),47…63 Hz

100 VA @ 120V ac130 VA @ 240V ac

2.0 A✶ @ 5V

0.8 A� @ 24 V250 mA

25 A @ 132V ac 10Ω sourceimpedance40 A @ 265V ac 10Ω sourceimpedance

10 ms…10 s

For both +5V dcand for +24V dc

8 modules‡

1769-PB2Compact 24V dcExpansion PowerSupply

19.2…31.2V dc 50 VA @ 24V dc2.0 A✶ @ 5V

0.8 A� @ 24 V⎯ 30 A @ 31.2V dc 10 ms…10 s

1769-PA4Compact 124/240Vac ExpansionPower Supply

85…132V ac or170…265V ac(switch selectable),47…63 Hz

200 VA @ 120V ac240 VA @ 240V ac

4.0 A➤ @ 5V

2.0 A� @ 24 V⎯

25 A @ 132V ac 10Ω sourceimpedance40 A @ 265V ac 10Ω sourceimpedance

5 ms…10 s

1769-PB4Compact 24V dcExpansion PowerSupply

19.2…32V dc 100 VA @ 24V dc4.0 A� @ 5V

2.0 A� @ 24 V⎯ 30 A @ 31.2V dc 5 ms…10 s

CCeerrttiiffiiccaattiioonnss:: UL, CSA (Class I, Division 2, Group A, B, C, D), CESee the Product Certifications link at http://ab.com for Declarations of Conformity, Certifications, and other certifications details.✶2000 mA @ 5V (0…55 °C)2000 mA @ 5V (55…60 °C)�800 mA @ 24V (0…55 °C)800 mA @ 24V (55…60 °C)§Up to 8 I/O modules can be connected on either side of the power supply for a maximum of 16 modules.♣ When configuring your system using a MicroLogix 1500 controller, only one expansion cable, one expansion power supply, and a total of 8 I/O modules may be used in a maximum of two

banks of I/O modules. The expansion power supply cannot be directly connected to the MicroLogix 1500 controller.➤4000 mA @ 5V (0…55 °C)4000 mA @ 5V (55…60 °C)�2000 mA @ 24V (0…55 °C)1700 mA @ 24V (55…60 °C)�4000 mA @ 5V (0…55 °C)1700 mA @ 5V (55…60 °C)�2000 mA @ 24V (0…55 °C)2000 mA @ 24V (55…60 °C)

Page 122: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

122

Publication 1769-SG002E-EN-P — January 2007

1769 Power Requirements and TransformerSizing

Page 123: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

123

Publication 1769-SG002E-EN-P — January 2007

Validating System Power

After you calculate the current consumed by your system, use the graphs on page 91to verify that your power supply has adequate capacity for its bank of I/O modules.Compare the graphs to your calculated totals for the following:

� Total 5V dc

� Total 24V dc

� Total 24V dc sensor power (1769-PA2 only)

If your power supply load is at or near the limits of the allowable ranges shown in thegraphs on page 91, you must add an additional I/O bank.

Important: The additional I/O bank must include a power supply. An endcap/terminator (1769-ECR or 1769-ECL) must also be used if the I/O bank is the lastin the system.

1768 Power SuppliesThe 1768 backplane requires one 1768 power supply. The power supply is a dualinput supply that operates in multiple ranges. The power supply also offers a 24V dcexternal power source. The CompactLogix power supply requires that a 1768CompactLogix controller be installed to power the system.

• The power supply sends 24V dc to the controller located in slot 0.

• The controller converts the 24V dc to 5V dc and 24V dc and distributes it asneeded.

– 5V and 24V power to 1769 I/O modules on the right side of the controller

– 24V power to communication or motion modules on the left side of thecontroller

Page 124: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

124

Publication 1769-SG002E-EN-P — January 2007

Calculate System Power Requirements

Compact I/O power supplies distribute power from either side of the power supply.For example, a 2 A at 5V dc power supply (1769-PA2, 1769-PB2) can provide 1 A tothe right side of the power supply and 1 A to the left. A 4 A at 5V dc power supply(1769-PA4, 1769-PB4) can provide 2 A to the right side of the power supply and 2 Ato the left.

The 1768 modules do not have a distance rating to the 1768 power supply. For the1769 I/O modules in the 1768 system, the distance rating is from the controller andnot the 1768 power supply.

Page 125: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

125

Publication 1769-SG002E-EN-P — January 2007

Cat. No. Number of Modules

Module Current Requirements (mA)Calculated Current (mA) = (number of modules) x (modulecurrent requirements)

5V dc 24V dc 5V dc 24V dc1769-ARM 60 mA 0 mA

1769-ASCII 500 mA 0 mA

1769-HSC 425 mA 0 mA

1769-IA8I 90 mA§§ 0 mA

1769-IA16 115 mA 0 mA

1769-IF4 105 mA 60 mA♣♣

1769-IF4I 145 mA 125 mA

1769-IF4XOF2 120 mA 160 mA

1769-IF8 120 mA 70 mA

1769-IM12 100 mA 0 mA

1769-IG16 120 mA 0 mA

1769-IQ16 115 mA 0 mA

1769-IQ16F 110 mA 0 mA

1769-IQ32 170 mA 0 mA

1769-IQ32T 170 mA 0 mA

1769-IQ6XOW4 105 mA 50 mA

1769-IR6 100 mA 45 mA

1769-IT6 100 mA 40 mA

1769-OA8 145 mA 0 mA

1769-OA16 225 mA 0 mA

1769-OB8 145 mA 0 mA

1769-OB16 200 mA 0 mA

1769-OB16P 160 mA➤➤ 0 mA

1769-OG16 200 mA 0 mA

1769-OB32 300 mA 0 mA

1769-BOOLEAN 220 mA 0 mA

1769-OF2 120 mA 120 mA♣♣

1769-OF4CI 145 mA 140 mA

1769-OF4VI 145 mA 75 mA

1769-OF8C 145 mA 160 mA♣♣

1769-OF8V 145 mA 125 mA♣♣

1769-OV16 200 mA 0 mA

1769-OV32T 200 mA 0 mA

1769-OW8 125 mA 100 mA

1769-OW8I 125 mA 100 mA

1769-OW16 205 mA 180 mA

1769-L35E 660 mA 90 mA

1769-L35CR 680 mA 40 mA

1769-L32E 660 mA 90 mA

1769-L32C 680 mA 40 mA

1769-L31 330 mA 40 mA

1769-ADN 450 mA 0 mA

1769-SDN 440 mA 0 mA

1769-ECL✶ 5 mA 0 mA

1769-ECR✶ 5 mA 0 mA

Total Current Required:�

✶One 1769-ECL or 1769-ECR end cap/terminator is required in the system. The end cap/terminator used is dependent on your configuration.�The total current required must not exceed the power supply capacity listed below.‡Preliminary.§190 mA max.♣If the optional 24V dc Class 2 power supply is used, the 24V dc current draw from the bus is 0 mA.➤200 mA max.

Page 126: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

126

Publication 1769-SG002E-EN-P — January 2007

Power Supply Capacity

Attribute 1769-PA2 1769-PB2 1769-PA4 1769-PB4

Current Capacity (Amps) at 5V 2.0 A✶ 2.0 A✶ 4.0 A� 4.0 A‡

Current Capacity (Amps) at 24V 0.8 A§ 0.8 A§ 2.0 A♣ 2.0 A➤

Power Supply Output at 24V dc250 mA (0…55 °C)200 mA (55…60 °C)

— — —

✶2000 mA @ 5V (0…55 °C)2000 mA @ 5V (55…60 °C)�4000 mA @ 5V (0…55 °C)4000 mA @ 5V (55…60 °C)‡4000 mA @ 5V (0…55 °C)1700 mA @ 5V (55…60 °C)§800 mA @ 24V (0…55 °C)800 mA @ 24V (55…60 °C)♣2000 mA @ 24V (0…55 °C)1700 mA @ 24V (55…60 °C)➤2000 mA @ 24V (0…55 °C)2000 mA @ 24V (55…60 °C)

Page 127: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

127

Publication 1769-SG002E-EN-P — January 2007

Step 5 - Select:

� panel mount or DIN rail mount

� appropriate number of panels orDIN rails based on the number ofmodules and the physical layout

� one end cap per controller system

Mounting a Compact I/OSystem

You can panel mount or DIN rail mount a CompactLogix system. The CompactLogixsystem must be mounted so that the modules are horizontal to each other.

If you separate modules into multiple banks, the banks can be vertical or horizontalto each other.

Ground the System

You can ground a Compact I/O system through the:

� non-coated, steel DIN rail.

� panel-mount screw hole containing the ground strap.

Page 128: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

128

Publication 1769-SG002E-EN-P — January 2007

Divide I/O Modules into Separate Banks

If you divide the modules into multiple banks:

� the controller or adapter must be in the leftmost position of the first bank.

� each bank needs its own power supply.

� use expansion cables to connect the banks.

� the last I/O bank requires an end cap.

Add End Caps

The controller or adapter is the leftmost module in the Compact I/O system. Thecontroller or adapter has built-in termination, so the leftmost end of the system isterminated.

The final I/O bank in the Compact I/O system needs an end cap on the end withoutthe expansion cable.

For a Order

Right end cap 1769-ECRLeft end cap 1769-ECL

If you add a And connect the chassis from Use this cable✶

Second bankRight to left 1769-CRLxRight to right 1769-CRRx

Third bankRight to left 1769-CRLxRight to right 1769CRRxLeft to left 1769-CLLx

✶Where x = 1 for 1 ft. (305 mm) or 3 for 3.28 ft. (1 m)

Page 129: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

129

Publication 1769-SG002E-EN-P — January 2007

Power Supply Distance Rating

Modules can be placed to the left and the right of the power supply. As many as eightI/O modules can be placed on each side of the power supply.

Each 1769 module also has a power supply distance rating (the number of modulesfrom the power supply). Each module must be located within its distance rating. Seethe specifications for the module to determine its distance rating.

The CompactLogix controller has a power supply distance rating of four modules. Thecontroller must be the leftmost module in the first bank of the system. The maximumconfiguration for the first bank of a CompactLogix controller is the controller andthree I/O modules to the left of the power supply and eight I/O modules to the right ofthe power supply.

Mounting Dimensions

You can mount the 1769 Compact I/O system with a dimensional template.

Panel Mounting with the Dimensional Template

Compact I/O System with Expansion PowerSupply and End Caps

Page 130: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

130

Publication 1769-SG002E-EN-P — January 2007

Step 6 - Select:

� the appropriate programmingsoftware and any options

� other software packages for yourapplication

Selecting SoftwareYour selection of modules and network configuration determines what softwarepackages you need to configure and program your system.

If you have a You need Order this catalog number

1768 or 1769CompactLogix controller

RSLogix 5000 EnterpriseSeries software

9324 series

(RSLogix 5000 EnterpriseSeries software)

1764 MicroLogix 1500packaged controller

RSLogix 500 programmingsoftware

9324-RL0300ENE

DeviceNet interface

(scanner or adapter)

RSNetWorx for DeviceNet

(comes with thestandard/NetWorx option ofRSLogix 5000 EnterpriseSeries software)

9324-RLD300NXENE(RSLogix 5000 EnterpriseSeries software plusRSNetWorx option)

or

9357-DNETL3 (RSNetWorxfor DeviceNet software)

Communication card in aworkstation

RSLinx software

(RSLinx Lite comes withRSLogix 5000 EnterpriseSeries software)

9324 series

(RSLogix 5000 EnterpriseSeries software)

Page 131: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

131

Publication 1769-SG002E-EN-P — January 2007

RSLogix 5000Software

RSLogix 5000 Enterprise Series software is designed to work with RockwellAutomation’s Logix platforms. RSLogix 5000 Enterprise Series software is an IEC61131-3 compliant software package that offers relay ladder, structured text, functionblock diagram, and sequential function chart editors for you to develop applicationprograms. Create your own instructions by encapsulating a section of logic in anyprogramming language into an add-on instruction.

RSLogix 5000 Enterprise Series software also includes axis configuration andprogramming support for motion control. With RSLogix 5000 Enterprise Seriessoftware, you need only one software package for sequential, process, drive, motioncontrol, and safety programming.

Page 132: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

132

Publication 1769-SG002E-EN-P — January 2007

Available Features

Service Edition9324-RLD000xxE✶♠♠

Mini Edition 9324-RLD200xxE✶

Lite Edition 9324-RLD250xxE✶

Standard Edition9324-RLD300xxE✶

Standard/NetWorx Edition9324-RLD300NXxxE✶

Full Edition: NodeLocked 9324-RLD600xxEConcurrentLicense 9324-RLD600xxF✶

ProfessionalEdition 9324-RLD700NXxxE✶

Logix5000 controllers supported All♠ CompactLogixFlexLogix

CompactLogixFlexLogix

All All All‡ All

Relay ladder diagram editor§Upload/download andview

Full support Full support Full support Full support Full support Full support

Function block diagram editor9324-RLDFBDENE

Upload/download andview

Upload/downloadAvailable separately

Full supportUpload/downloadAvailable separately

Upload/downloadAvailable separately

Full support Full support

Sequential function chart editor9324-RLDSFCE

Upload/download andview

Upload/downloadAvailable separately

Full supportUpload/downloadAvailable separately

Upload/downloadAvailable separately

Full support Full support

Structured text editor9324-RLDSTXE

Upload/download andview

Upload/downloadAvailable separately

Full supportUpload/downloadAvailable separately

Upload/downloadAvailable separately

Full support Full support

PhaseManager9324-RLDPME

Upload/downloadUpload/downloadAvailable separately

Upload/downloadAvailable separately

Upload/downloadAvailable separately

Upload/downloadAvailable separately

Included Included

GuardLogix Safety9324-RLDGLXE�

Upload/download andview

NA NAUpload/downloadAvailable separately

Upload/downloadAvailable separately

Included Included

Highly integrated motionUpload/download andview

Upload/download Full support Full support Full support Full support Full support

Graphical trending Full support Full support� Full support� Full support Full support Full support Full support

DriveExecutive Lite9303-4DTE01ENE

Available separately Available separately Available separately Included Included Included Included

PIDE autotune9323-ATUNEENE

Available separately Available separately Available separately Available separately Available separately Included Included

RSMACC audit support Included Included Included Included Included Included Included

FuzzyDesigner9324-RLDFZYENE�

NA Available separately Available separately Available separately Available separately Available separately Available separately

RSLogix Emulate 50009310-WED200ENE

Available separately NA NA Available separately Available separately Available separately Included

Logix CPU security Included Included Included Included Included Included Included

Routine source protection Included Included Included Included Included Included Included

Standalone security server Included Included Included Included Included Included Included

RSLinx Classic software Lite included Lite included Lite included Lite included Lite included Lite included OEM included�

RSNetWorx for ControlNet softwareRSNetWorx for DeviceNet softwareRSNetWorx for EtherNet/IP software�

Available separately Available separately Available separately Available separately Included Available separately Included

RSLogix 5000 Enterprise Series SoftwareRequirements

Description Value

Personal computerPentium II 450 MHz minPentium III 733 MHz (or better) recommended

Software requirements

Supported operating systems:• Microsoft Windows XP Professional version 2002 (with Service Pack 1 or 2) or XPHome version 2002• Microsoft Windows 2000 Professional with Service Pack 1, 2, or 3• Microsoft Windows Server 2003

RAM128 MB of RAM min256 MB of RAM recommended

Hard disk space 100 MB of free hard disk space (or more based on application requirements)

Video requirements256-color VGA graphics adapter800 x 600 min resolution (True Color 1024 x 768 recommended)

Select the RSLogix 5000 Enterprise SeriesSoftware Package

Page 133: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

133

Publication 1769-SG002E-EN-P — January 2007

RSLogix Architect9326-LGXARCHENE�

Available separately Available separately Available separately Available separately Available separately Available separately Included

FBD ActiveX faceplates Included Included Included Included Included Included Included

Tag data upload/download Included Included Included Included Included Included Included

RSLogix 5000 project compare Included Included Included Included Included Included Included

Tag custom data monitor Included Included Included Included Included Included Included

RSView demo (50 tags/2 hours) Available separately Available separately Available separately Available separately Available separately Available separately Included

Upgrades

To Standard: 9324-RLD0U3xxETo Full: 9324-RLD0U6xxETo Professional:9324-RLD0U7xxE

To Standard: 9324-RLD2U3xxETo Professional:9324-RLD2U7xxE

To Full: 9324-RLD25U6xxETo Professional:9324-RLD25U7xxE

To Full: Multi-language pack�

NA

Node Locked toConcurrent License:9324-RLD6U6FxxUTo Professional:9324-RLD6U7xxE

NA

✶Replace xx in the catalog number with the appropriate language designation: ZH=Chinese, EN=English, FR=French, DE=German, IT=Italian, JP=Japanese, KO=Korean, PT=Portuguese, andES=Spanish.

♠Service Edition supports controllers running firmware revision 12 and later.‡Full Edition supports controllers running firmware revision 10 and later.§A multiple language editor package is available as 9324-RLDMLPE. It contains the function block, sequential function chart, and structured text editors at a reduced price.�RSNetWorx for ControlNet software is 9357-CNETL3. RSNetWorx for DeviceNet software is 9357-DNETL3. RSNetWorx for EtherNet/IP software is 9357-ENETL3. They are available together

as 9357-ANETL3.�The multiple language editor package (9324-RLDMLPE) is not the same as an upgrade, but it extends the programming languages to match those in a Full package.�As of RSLogix 5000 programming software, version 15.�As of RSLogix 5000 programming software, version 16.

Available Features

Service Edition9324-RLD000xxE✶♠♠

Mini Edition 9324-RLD200xxE✶

Lite Edition 9324-RLD250xxE✶

Standard Edition9324-RLD300xxE✶

Standard/NetWorx Edition9324-RLD300NXxxE✶

Full Edition: NodeLocked 9324-RLD600xxEConcurrentLicense 9324-RLD600xxF✶

ProfessionalEdition 9324-RLD700NXxxE✶

Page 134: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

134

Publication 1769-SG002E-EN-P — January 2007

RSLogix 500ProgrammingSoftware

The RSLogix 500 ladder-logic programming package (9324-RL series) supportsAllen-Bradley’s MicroLogix families of processors and SLC 500 controllers. RSLogix500 software was the first PLC programming software to offer unbeatable productivitywith an industry-leading user interface.

RSLogix 5000 Enterprise Series SoftwareRequirements

Description Value

Personal computerPentium II 450 MHz minPentium III 733 MHz (or better) recommended

Software requirements

Supported operating systems:� Microsoft Windows XP Professional, version 2002 (with Service Pack 1), or XP

Home, version 2002� Microsoft Windows 2000 Professional with Service Pack 1, 2, or 3� Microsoft Windows NT, version 4.0 with Service Pack 5 or 6A

RAM128 MB of RAM min256 MB of RAM recommended

Hard disk space100 MB of free hard disk space(or more based on application requirements)

Video requirements256-color VGA graphics adapter800 x 600 min resolution (True Color 1024 x 768 recommended)

Page 135: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

135

Publication 1769-SG002E-EN-P — January 2007

RSNetWorxSoftware

RSNetWorx software is the configuration tool for your control network. WithRSNetWorx software you can create a graphical representation of your networkconfiguration and configure the parameters that define your network.

Use RSNetWorx software for:

� ControlNet software to schedule network components. The software automaticallycalculates network bandwidth for the entire network, as well as the bandwidth usedby each network component. You must have RSNetWorx software to configure andschedule ControlNet networks.

� DeviceNet software to configure DeviceNet I/O devices and create a scan list. TheDeviceNet scanner stores the configuration information and scan list.

� EtherNet/IP software to configure EtherNet/IP devices using IP addresses or hostnames.

Page 136: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

136

Publication 1769-SG002E-EN-P — January 2007

RSNetWorx Software Requirements

Description EtherNet/IP ControlNet DeviceNetPersonal computer Intel Pentium or Pentium-compatible computer

Operating system

Supported operating systems:• Microsoft Windows XP• Microsoft Windows 2000• Microsoft Windows 2000 Terminal Server• Microsoft Windows NT version 4.0 with Service Pack 6 or later• Microsoft Windows ME• Microsoft Windows 98

RAM32 MB of RAM minMore memory is required for large networks

Hard disk space

Minimum: 108 MB (includesprogram and hardware files)Full support: 115...125 MB(includes program, online help,tutorial, and hardware files)

Minimum: 115 MB (includesprogram and hardware files)Full support: 168...193 MB(includes program, online help,tutorial, and hardware files)

Minimum: 190 MB (includesprogram and hardware files)Full support: 230...565 MB(includes program, online help,tutorial, and hardware files)

Video requirements16-color VGA graphics adapter640 x 480 resolution minimum800 x 600 resolution recommended

OtherRSLinx Lite software, version 2.41or later, to use RSNetWorx softwareonline

RSLinx Lite software, version 2.4 orlater, to use RSNetWorx softwareonline

RSLinx Lite software, version 2.4 orlater, to use RSNetWorx softwareonline

In some cases, RSNetWorx software comes bundled with controller programmingsoftware packages.

Select the RSNetWorx Software Package

Description

9357-CNETL3 RSNetWorx for ControlNet software9357-DNETL3 RSNetWorx for DeviceNet software9357-ENETL3 RSNetWorx for Ethernet/IP software

9357-ANETL3RSNetWorx for ControlNet, Ethernet/IPand DeviceNet software

9357-CNETMD3E RSNetWorx for ControlNet software withMD, includes DriveExecutive Lite software

9357-DNETMD3E RSNetWorx for DeviceNet software withMD

9357-ENETMD3E RSNetWorx for EtherNet/IP software withMD

9357-ANETMD3ERSNetWorx for ControlNet, DeviceNet, andEthernet/IP software with MD

Page 137: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

137

Publication 1769-SG002E-EN-P — January 2007

SummaryUse a spreadsheet to record the amount and type of devices your CompactLogixsystem needs. For example, this sample system…

…could result in this spreadsheet.Controller 1 - 1769-L35E

Device Number of Points Needed Cat. No. I/O Points per Module Number of Modules

120V ac digital inputs 12 1769-IA816 16 14…20 mA analog inputs 3 1769-IF4XOF2 4 1

4…20 mA analogoutputs

2 1769-IF4XOF2 2

1

(part of same module fromanalog input requirements)

DeviceNet scanner NA 1769-SDN NA 1DeviceNet adapter NA 1769-ADN NA 1Remote 24V dc digitaloutputs

30 1769-OB16 16 2

Remote contact outputs 3 1769-OW6 6 1

Controller 1 subtotal

2 local 1769 I/O modules

1 1769-SDN module

1 remote 1769-ADN module

3 remote 1769 I/O modules

Page 138: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

138

Publication 1769-SG002E-EN-P — January 2007

As you select devices for your CompactLogix system, keep in mind these guidelines.� Step Remember to Select

1 Select I/O devices

Use a spreadsheet to record the:

� location of the device.

� number of points needed.

� appropriate catalog number.

� number of points available per module.

� number of modules.

� I/O modules

2 Select a 1492 wiring system

Choose a wiring system as an alternative to the terminalblock that comes with the module.

� Wiring system (instead of the terminal block that comeswith the module)

� PanelConnect modules and cables to connect inputmodules to sensors

� Expansion cables for multiple banks of I/O modules3 Select controllers

Select the appropriate controller based on the type andnumber of I/O points needed.

1768 CompactLogix controller

1769 CompactLogix controller

1764 MicroLogix 1500 packaged controllers

4 Select power supplies

Install additional power supplies if power consumptionexceeds the maximum for a single power supply.

Power supply specifications

5 Select the mounting requirements

Determine whether to panel mount or DIN rail mount theCompactLogix system.

Planning the mounting requirements

6 Select software

Determine the software products you need to configure andprogram your application based on the system design.

Available software products

Programming software

Network configuration software

Page 139: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

139

Publication 1769-SG002E-EN-P — January 2007

Page 140: 1769 SelectionGuide feb 06 - Rockwell Automation · 2019. 8. 15. · Publication 1769-SG002E-EN-P — January 2007 Compact I/O Modules What's new: 1769-IG16 1769-OG16 1769-OB32T 1769-BOOLEAN

Publication 1769-SG002E-EN-P – November 2006 Copyright ©2006 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.Supersedes 1769-SG002D-EN-P ¾ May 2005

ControlLogix, POINT I/O, FLEX I/O, FLEX Ex, FLEXArmor, Compact I/O, Logix5550, FlexLogix, CompactLogix, DriveLogix, ProcessLogix, PowerFlex, SoftLogix5800,

MicroLogix 1500, PLC-5, PLC-3, PLC-2, SLC, DH+, Allen-Bradley, Rockwell Automation, RSLogix, RSLogix 5000 Enterprise Series, RSLogix 500, RSLinx,

PanelConnect, CompactFlash, RSNetWorx, and Rockwell Software are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are

property of their respective companies.

Part Number 953030-06