17-06 CNE Tahlequah Casino - Addendum 015...spare 2520 boh corridor ltg spare 1400 boh kitchen ltg...
Transcript of 17-06 CNE Tahlequah Casino - Addendum 015...spare 2520 boh corridor ltg spare 1400 boh kitchen ltg...
SPARE 2520 BOH CORRIDOR LTGSPARE 1400 BOH KITCHEN LTGSPARE 1310 BOH RECEIVING LTGSPARE 1000 BOH OFFICES/SUPPORT RM LTG
SPARE 1380 BOH OFFICES/SUPPORT RM LTG
SPARE 270 BOH OFFICES/SUPPORT RM LTG
SPARE 550 BAN�UET STORAGE LTG
SPARE 1090 BAN�UET FOOD SERVICES
SPARE 1100 E�TERIOR EGRESS LTGSPARE 100 E�IT SIGNSSPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARE
SPARE�FMR 'TTCEL' SPARE
SPARE
.
1
.
1311
35K
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
BOH CORRIDOR LIGHTING 1260 2880 E�TERIOR COLUMN LIGHTINGBOH KITCHEN LIGHTING 1820 2880 E�TERIOR COLUMN LIGHTINGBOH RECEIVING LIGHTING 1250 2880 E�TERIOR COLUMN LIGHTINGBOH OFFICES 2220 2880 E�TERIOR COLUMN LIGHTING
2080 2880 E�TERIOR COLUMN LIGHTING520 2880 E�TERIOR COLUMN LIGHTING
SPARE 2560 E�TERIOR COLUMN LIGHTINGSPARE 2560 E�TERIOR COLUMN LIGHTINGSPARE 2560 E�TERIOR COLUMN LIGHTINGSPARE 2560 E�TERIOR COLUMN LIGHTINGSPARE 2560 E�TERIOR COLUMN LIGHTINGSPARE 2560 E�TERIOR COLUMN LIGHTINGSPARE 3040 CANOPY LIGHTINGSPARE 3040 CANOPY LIGHTINGSPARE 1660 CANOPY LIGHTINGSPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARE
.
1
.
6050
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
E�TERIOR COLUMN LIGHTING 2880 2110E�TERIOR COLUMN LIGHTING 2880 2110 KEF-1E�TERIOR COLUMN LIGHTING 2560 2110E�TERIOR COLUMN LIGHTING 2880 2110E�TERIOR COLUMN LIGHTING 2240 2110 KEF-2E�TERIOR COLUMN LIGHTING 2560 2110E�TERIOR COLUMN LIGHTING 2880 585E�TERIOR COLUMN LIGHTING 1920 585 FC-12BAN�UET FOOD PREP LIGHTING 1820 585
820 21380440 21380 DISHWASHER
E01 COLLECTOR 440 21380440 60002330 6000 DISHWASHER BOOSTER HEATER
E49 POWERED SINK 2330 60002330 8100440 8100 DISHWASHER
E50 COLLECTOR 440 8100440 7330
CANOPY LIGHTING 1660 7330 DISHWASHER BOOSTER HEATERSPARE 7330
.
1
.
214178
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
15820 1750CRAC-1 15820 1750 CCU-1
15820 17503950
SPARE 3950 CCU-2A3950
5490 2690CRAC-3 5490 2690 CCU-2B
5490 2690440 3950
FC-10 440 3950 CCU-3440 3950
SPARE SPARE
5820CRAC-2 5820 SPARE
5820SPARE
SPARE SPARESPARE
.
1
.
144120
35K
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
830 445FC-5 830 445 FC-11
830 445445 SPARE
FC-6 445 SPARE445 SPARE580 SPARE
FC-7 580 SPARE580 SPARE
SPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARE
.
1
.
87
35K
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
7100 830E53 DISHWASHER 7100 830 FC-2
7100 8307330 580
E53 DISHWASHER BOOSTER HEATER 7330 580 FC-37330 5802330 830
E49 POWERED SINK 2330 830 FC-42330 830415 840
E50 COLLECTOR 415 840 EF-1415 8407100 415
E53 DISHWASHER 7100 415 COLLECTOR E507100 4157330 SPARE
E53 DISHWASHER BOOSTER HEATER 7330 SPARE7330 SPARE
SPARE SPARESPARE SPARESPARE SPARE
.
1
.
127105
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
580 SPAREFC-1 580 SPARE
580 SPARE3050 SPARE
KEF-3 3050 SPARE3050 SPARE1330 SPARE
KEF-4 1330 SPARE1330 SPARE2110 SPARE
KEF-5 2110 SPARE2110 SPARE2110 SPARE
KEF-6 2110 SPARE2110 SPARE445 SPARE
FC-8 445 SPARE445 SPARE
SPARE SPARESPARE SPARESPARE SPARE
.
1
.
3529
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
33
3
3
3
3
3
3
3
3
3
3
3
SITE LIGHTING 2640 2640 SITE LIGHTING2640 2640
SITE LIGHTING 3300 3300 SITE LIGHTING3300 3300
SITE LIGHTING 2970 2970 SITE LIGHTING2970 2970
SITE LIGHTING 3300 2640 SITE LIGHTING3300 2640
SITE LIGHTING 2640 2310 SITE LIGHTING2640 2310
SITE LIGHTING 2640 SPARE2640 SPARE
SPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARE
.
1
.
7563
65K
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2
2
2
2
2
2
2
2
2
2
2
3
1
1
35K
35K
35K
35K
1
3
3
3
3
3
3
3
3
3
2
2
2
2
22
2
2
2
2
2
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E0.20
PANEL SCHEDULES
RUN LIGHTING CIRCUIT THROUGH CORRESPONDING LIGHTING CONTRACTOR.1
SHEET NOTES�
05/22/18 ADDENDUM #101
07/13/18 ADDENDUM #152
400 4001200 400400 400
1200 400400 400
1200 400400 400
1200 400400 400
1200 400400 400
1200 400400 400
1200 400400 400
1200 400400 400400 400
IDF ROOM RECEPTACLES 400 SPARESPARE SPARESPARE SPARE
.
1
.
5921
35K
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
MENS RESTROOM RECEPTACLES 1200 1200MENS RESTROOM RECEPTACLES 1200 1200MENS RESTROOM RECEPTACLES 1000 1000MENS RESTROOM RECEPTACLES 1000 1000HAND DRYER 1400 1400 HAND DRYERHAND DRYER 1400 1400 HAND DRYERHAND DRYER 1400 1400 HAND DRYERHAND DRYER 1400 1400 HAND DRYERMENS RESTROOM RECEPTACLES 600 600
400 1200 CONFERENCE CENTER SIGNAGE400 1200 CONFERENCE CENTER SIGNAGE400 1200 CONFERENCE CENTER SIGNAGE400 1200 CONFERENCE CENTER SIGNAGE400 1200 CONFERENCE CENTER SIGNAGE200 1200 CONFERENCE CENTER SIGNAGE
ROLL-UP DOOR CC1 1180 1200 CONFERENCE CENTER SIGNAGEROLL-UP DOOR CC2 1180 1200 CONFERENCE CENTER SIGNAGEVESTIBULE RECEPTACLES 400 400 VESTIBULE RECEPTACLESVESTIBULE RECEPTACLES 400 400 VESTIBULE RECEPTACLESVESTIBULE SLIDING DOOR 600 800 RESTROOM RECEPTACLESVESTIBULE SLIDING DOOR 600 SPARE
.
1
.
10839
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
600 600 BREAK-OUT ROOM RECEPTACLESCONVENIENCE RECEPTACLES 600 600 BREAK-OUT ROOM RECEPTACLESEVS STORAGE RECEPTACLES 400 400 BREAK-OUT ROOM RECEPTACLESEVS STORAGE RECEPTACLES 400 400 BREAK-OUT ROOM RECEPTACLESEVS STORAGE RECEPTACLES 600 600 BREAK-OUT ROOM RECEPTACLES
1000 600 BREAK-OUT ROOM RECEPTACLES1040 200 BREAK-OUT ROOM RECEPTACLES1040 400 BREAK-OUT ROOM RECEPTACLES
UTILITY RECEPTACLES 400 600 BREAK-OUT ROOM RECEPTACLESUTILITY RECEPTACLE 200 600 BREAK-OUT ROOM RECEPTACLESUTILITY RECEPTACLES 400 600 CONVENIENCE RECEPTACLESUTILITY RECEPTACLES 800 600SPARE 800MENS RESTROOM RECEPTACLES 600 900 DIGITAL DISPLAYMENS RESTROOM RECEPTACLES 800 600 UTILITY RECEPTACLESSPARE 400 CONFERENCE ROOM RECEPTACLEVESTIBULE RECEPTACLES 400 400 CONFERENCE ROOM RECEPTACLEUTILITY RECEPTACLES 400 600 CONFERENCE ROOM RECEPTACLEDIGITAL DISPLAY 900 600 CONFERENCE ROOM RECEPTACLEDIGITAL DISPLAY 900 SPAREDIGITAL DISPLAY 900 SPARE
.
1
.
6423
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
MENS RESTROOM RECEPTACLES 1400 400 CONVENIENCE RECEPTACLESMENS RESTROOM RECEPTACLES 1400 600 IDF OFFICE RECEPTACLESMENS RESTROOM RECEPTACLES 1400 400 MARKETING RECEPTACLESHAND DRYER 1400 600 MARKETING RECEPTACLESHAND DRYER 1400 400 MARKETING RECEPTACLES
1400 1000 MARKETING RECEPTACLES1400 800 CONVENIENCE RECEPTACLES1400 600 CONVENIENCE RECEPTACLES
HAND DRYER 1400 800 TOILET RECEPTACLESHAND DRYER 1400 800 TOILET RECEPTACLESUTILITY RECEPTACLES 400 SPAREVESTIBULE RECEPTACLES 400 SPAREEVS UTILITY RECEPTACLES 600 400 UTILITY RECEPTACLESVESTIBULE RECEPTACLES 600 600VESTIBULE RECEPTACLES 600 600VESTIBULE DOORS 800 400 CONNECTION VESTIBULE DOORREVOLVING DOOR LIGHTS 600 400 CONVENIENCE RECEPTACLESREVOLVING DOOR POWER 1000 500 WS-1
1000 500 WH-1SPARE 500 WH-2SPARE 100 CP-1
.
1
.
8430
.
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
400 400 UTILITY RECEPTACLES400 1180 DOOR 1400 1180 DOOR 2400 600 UTILITY RECEPTACLES600 400 UTILITY RECEPTACLES600 400 RECEIVING RECEPTACLES400 400 RECEIVING RECEPTACLES400 1650 FORKLIFT CHARGER RECEPTACLE600 1650600 1650
KEY RECEPTACLES 600 1650KEY RECEPTACLES 600 200 RECEIVING RECEPTACLE
600 200 RECEIVING RECEPTACLE600 400 TRASH RECEPTACLE600 400 MDF ROOM RECEPTACLES600 400 TIME CLOCK RECEPTACLE
CONTACTOR COIL 100 400 SECURITY STORAGE RECEPTACLESTAGE PROTECTOR � SCREEN 1500 1000 KEY ROOM PRINTER RECEPTACLESPARE SPARESPARE SPARESPARE SPARE
.
1
.
6724
.
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
VIP EVENT RECEPTACLES 600 400 IDF ROOM RECEPTCLESVIP EVENT RECEPTACLES 400 500 STAGE VIDEO WALLVIP EVENT RECEPTACLES 1000 500 STAGE VIDEO WALLVIP EVENT RECEPTACLES 600 500 STAGE VIDEO WALLDINING RECEPTACLES 600 500 STAGE VIDEO WALLDINING RECEPTACLES 600 500 STAGE VIDEO WALLDINING RECEPTACLES 400 500 STAGE VIDEO WALLDINING RECEPTACLES 400 500 STAGE VIDEO WALLDINING RECEPTACLES 400 500 STAGE VIDEO WALLDINING RECEPTACLES 800 900 DIGITAL DISPLAYDINING RECEPTACLES 800 900 DIGITAL DISPLAYDINING RECEPTACLES 800 900 DIGITAL DISPLAYDINING RECEPTACLES 600 900 DIGITAL DISPLAYEDR POS 1200 900 DIGITAL DISPLAYEDR ATM 1000 1200 DIGITAL DISPLAYEDR RECEPTACLE 400 SPAREEDR RECEPTACLE 1000 SPAREDINING WAITING RECEPTACLE 400 SPAREDINING WAITING RECEPTACLE 400 SPAREDINING POS 1200 SPARESPARE SPARE
.
1
.
6624
.
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
MENS RESTROOM RECEPTACLES 800 600 CONVENIENCE RECEPTACLESMENS RESTROOM RECEPTACLES 600 600 OFFICE RECEPTACLESSPARE 1000 OFFICE RECEPTACLES
800 600 GREEN ROOM RECEPTACLES600 600 GREEN ROOM RECEPTACLES
SPARE 600 GREEN ROOM RECEPTACLESUTILITY RECEPTACLES 400 400 GREEN ROOM RECEPTACLESEDR RECEPTACLES 600 400 GREEN ROOM RECEPTACLESEDR RECEPTACLES 400 400 STAGE LIFTEDR RECEPTACLES 500 400 AUDIT RECEPTACLESEDR RECEPTACLES 1000 400 AUDIT RECEPTACLESCONVENIENCE RECEPTACLES 600 400 AUDIT RECEPTACLESSPARE 400 AUDIT RECEPTACLESOFFICE RECEPTACLES 600 400 AUDIT RECEPTACLESOFFICE RECEPTACLES 1000 400 AUDIT RECEPTACLESVAV BO�ES 800 400 AUDIT RECEPTACLESVAV BO�ES 700 400 AUDIT RECEPTACLESVAV BO�ES 300 600EF-6 1200 SPAREROOFTOP RECEPTACLES 800 SPARESPARE SPARE
.
1
.
5721
.
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2
2
2
2
45 1255721
54 1506624
VAV BO�ES 300 1000 PROJECTOR SCREENVAV BO�ES 400 1000 PROJECTOR SCREENVAV BO�ES 300 1000 PROJECTOR SCREENEF-4 1200 1000 PROJECTOR SCREENEF-5 1200 1000 PROJECTOR SCREENROOFTOP RECEPTACLES 600 1000 PROJECTOR SCREENROOFTOP RECEPTACLES 1000 1200 PROJECTOR AND LIFTCONTACTOR COIL 100 1200 PROJECTOR AND LIFTPROJECTOR SCREEN 1000 1000 PROJECTOR SCREENPROJECTOR SCREEN 1000 1000 PROJECTOR SCREENPROJECTOR AND LIFT 1200 1000 PROJECTOR SCREENPROJECTOR AND LIFT 1200 1000 PROJECTOR SCREENPROJECTOR AND LIFT 1200 1200 PROJECTOR AND LIFTPROJECTOR AND LIFT 1200 1200 PROJECTOR AND LIFTPROJECTOR AND LIFT 1200 1200 PROJECTOR AND LIFTPROJECTOR AND LIFT 1200 1200 PROJECTOR AND LIFTPROJECTOR AND LIFT 1200 600 DIGITAL DISPLAYSPARE 600 DIGITAL DISPLAYSPARE 300 VAV BO�ESSPARE 300 VAV BO�ESSPARE SPARE
.
1
.
9635
35K
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
35K
3
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E0.21
PANEL SCHEDULES
05/22/18 ADDENDUM #101
06/01/18 ADDENDUM #112
07/13/18 ADDENDUM #153
SLOT POWER 900 600 SLOT POWERSLOT POWER 900 1200 SLOT POWERSLOT POWER 1200 1200 SLOT POWERSLOT POWER 1200 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 1200 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 1200 SLOT POWERSLOT POWER 900 1200 SLOT POWERSLOT POWER 900 600 SLOT POWERSLOT POWER 900 600 SLOT POWERSLOT POWER 600 900 SLOT POWERSLOT POWER 600 900 SLOT POWERSLOT POWER 600 900 SLOT POWERSLOT POWER 600 600 SLOT POWERSLOT POWER 900 1000 ATM RECEPTACLESLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSPARE SPARESPARE SPARESPARE SPARE
.
1
.
8932
.
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
SLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 600 SLOT POWERSLOT POWER 900 600 SLOT POWERSLOT POWER 1200 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 1200 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 600 SLOT POWERSLOT POWER 1200 900 SLOT POWERSLOT POWER 1200 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 1200 SPARESLOT POWER 900 SPARESPARE SPARESPARE SPARESPARE SPARE
.
1
.
8731
.
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
SLOT POWER 900 600 SLOT POWERSLOT POWER 900 600 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 1200 900 SLOT POWERSLOT POWER 1200 900 SLOT POWERSLOT POWER 1200 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 600 900 SLOT POWERATM POWER 1200 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 1200 SLOT POWERSPARE SPARESPARE SPARESPARE SPARESPARE SPARE
.
1
.
8731
.
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
SLOT POWER 900 1200 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 1200 1200 SLOT POWERSLOT POWER 1200 900 SLOT POWERSLOT POWER 1200 900 SLOT POWERSLOT POWER 900 1200 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 600 1200 SLOT POWERSLOT POWER 900 1200 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 1200 SPARESLOT POWER 900 SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARE
.
1
.
7728
.
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
SLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 1200 SLOT POWERSLOT POWER 900 1200 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 1200 SLOT POWERSLOT POWER 1200 1200 SLOT POWERSLOT POWER 900 1200 SLOT POWERSLOT POWER 900 1200 SLOT POWERSLOT POWER 1200 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 600 1200 SLOT POWERATM POWER 1200 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 900 900 SLOT POWERSLOT POWER 1200 900 SLOT POWERSLOT POWER 1200 1000 ATM RECEPTACLESPARE 600 SLOT POWERSPARE SPARESPARE SPARE
.
1
.
10136
.
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
.
1
.
##0
.
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
.
1
.
##0
.
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
SPARE SPARESPARE SPARESPARE 1020 BOH KITCHEN RESTROOM LTGSPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARESPARE SPARE
.
1
100/3
31
.
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
2468
1012141618202224262830323436384042
1357911131517192123252729313335373941
3
3
3
3
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E0.22
PANEL SCHEDULES
05/22/18 ADDENDUM #101
06/01/18 ADDENDUM #112
07/13/18 ADDENDUM #153
49 2400 110 PAYERS CLUB FI�TURE 'L14' TBD
50 2400 SPARE SPARE
51 2400 480 PLAYERS CLUB FI�TURE 'DL5' TBD
52 2400 SPARE SPARE
53 2400 1040 LOUNGE FI�TURE 'L16' 0-10V
54 2400 900 LOUNGE FI�TURE 'L16' 0-10V
55 2400 300 BAR FI�TURE 'LL-02' TBD
56 2400 300 BAR FI�TURE 'LL-03' TBD
57 2400 300 BAR FI�TURE 'LL-02' TBD
58 2400 SPARE SPARE
59 2400 720 GRAB AND GO FI�TURE 'DL8' TBD
60 2400 SPARE SPARE
61 2400 360 GRAB AND GO FI�TURE 'DL7' TBD
62 2400 SPARE SPARE
63 2400 140 VIP EVENT FI�TURE 'L16' 0-10V
64 2400 SPARE SPARE
65 2400 110 STEAKHOUSE WAITING FI�TURE 'L15'
66 2400 440 STEAK HOUSE FI�TURE 'L15'
67 2400 50 STEAK HOUSE BAR FI�TURE 'L15'
68 2400 110 STEAK HOUSE DINING FI�TURE 'L15'
69 2400 160 FI�TURE 'L15'
70 2400 SPARE SPARE
71 2400 180 FI�TURE 'DL4'
72 2400 480 STEAK HOUSE FI�TURE 'DL3'
73 2400 300 STEAK HOUSE BAR FI�TURE 'LL-03'
74 2400 300 STEAK HOUSE BAR FI�TURE 'LL-02'
75 2400 300 STEAK HOUSE BAR FI�TURE 'LL-02'
76 2400 250 SPARE SPARE
77 2400 200 STEAK HOUSE R.R. MIRRORS NON-DIM
78 2400 70 KITCHEN R.R. MIRRORS NON-DIM
79 2400 400 GAMING COLUMN LIGHTING ELEMENT TBD
80 2400 400 GAMING COLUMN LIGHTING ELEMENT TBD
81 2400 SPARE SPARE
82 2400 SPARE SPARE
83 2400 SPARE SPARE
84 2400 SPARE SPARE
85 2400 SPARE SPARE
86 2400 SPARE SPARE
87 2400 SPARE SPARE
88 2400 SPARE SPARE
89 2400 SPARE SPARE
90 2400 SPARE SPARE
91 2400 SPARE SPARE
92 2400 SPARE SPARE
93 2400 SPARE SPARE
94 2400 SPARE SPARE
95 2400 SPARE SPARE
96 2400 SPARE SPARE
DESCRIPTION
800 A
LOAD
120/208V, 3Φ,4WINCOMING LINE�
WATTAGERATING
DIMMERNUMBER LOCATION
MAINS RATING�
LOAD
LOAD�
LOAD
96 MODULES
CHANNELCONTROL
RACK�
KVA8
E1 2400 270 MENS 24 � WOMENS 22 FI�TURE 'L14'
E2 2400 540 MENS 11 � WOMENS 13 FI�TURE 'L14'
E3 2400 100 MENS 24 � WOMENS 22 FI�TURE 'L17' NON-DIM
E4 2400 500 MENS 11 � WOMENS 22 FI�TURE 'L17' NON-DIM
E5 2400 1100 GAMING FI�TURE 'L16' 0-10V
E6 2400 1170 GAMING FI�TURE 'L16' 0-10V
E7 2400 600 ENTRY FI�TURE 'LF-03' TBD
E8 2400 SPARE TBD
E9 2400 110 PLAYERS CLUB FI�TURE 'L14'
E10 2400 160 CASHIER FI�TURE 'L14'
E11 2400 1250 LOUNGE FI�TURE 'L16' 0-10V
E12 2400 320 BAR FI�TURE 'L16' 0-10V
E13 2400 390 VIP EVENT FI�TURE 'L16' 0-10V
E14 2400 SPARE SPARE
E15 2400 110 FI�TURE 'L15'
E16 2400 90 FI�TURE 'L15'
E17 2400 90 FI�TURE 'L15'
E18 2400 530 STEAKHOUSE FI�TURE 'L15'
E19 2400 70 STEAKHOUSE BAR FI�TURE 'L15'
E20 2400 90 FI�TURE 'L15'
E21 2400 SPARE SPARE
E22 2400 SPARE SPARE
E23 2400 SPARE SPARE
E24 2400 SPARE SPARE
E25 2400 SPARE SPARE
E26 2400 SPARE SPARE
E27 2400 SPARE SPARE
E28 2400 SPARE SPARE
E29 2400 SPARE SPARE
E30 2400 SPARE SPARE
E31 2400 SPARE SPARE
E32 2400 SPARE SPARE
E33 2400 SPARE SPARE
E34 2400 SPARE SPARE
E35 2400 SPARE SPARE
E36 2400 SPARE SPARE
E37 2400 SPARE SPARE
E38 2400 SPARE SPARE
E39 2400 SPARE SPARE
E40 2400 SPARE SPARE
E41 2400 SPARE SPARE
E42 2400 SPARE SPARE
E43 2400 SPARE SPARE
E44 2400 SPARE SPARE
E45 2400 SPARE SPARE
E46 2400 SPARE SPARE
E47 2400 SPARE SPARE
E48 2400 SPARE SPARE
DESCRIPTION
A
LOAD
120/208V, 3Φ,4WINCOMING LINE�
WATTAGERATING
DIMMERNUMBER LOCATION
MAINS RATING�
LOAD
LOAD�
LOAD
48 MODULES
CHANNELCONTROL
RACK�
KVA5
2
1 2400 1030 NORTHWEST E�TERIOR FI�TURE 'LF-01'
2 2400 620 WEST FRONT E�TERIOR FI�TURE 'LF-01'
3 2400 680 WEST FRONT E�TERIOR FI�TURE 'LF-01'
4 2400 550 WEST FRONT E�TERIOR FI�TURE 'LF-01'
5 2400 570 WEST FRONT E�TERIOR FI�TURE 'LF-01'
6 2400 920 WEST FRONT E�TERIOR FI�TURE 'LF-01'
7 2400 840 WEST FRONT E�TERIOR FI�TURE 'LF-01'
8 2400 970 WEST FRONT E�TERIOR FI�TURE 'LF-01'
9 2400 570 WEST FRONT E�TERIOR FI�TURE 'LF-01'
10 2400 620 WEST FRONT E�TERIOR FI�TURE 'LF-01'
11 2400 1030 SOUTH WEST E�TERIOR FI�TURE 'LF-01'
12 2400 SPARE
13 2400 1080 NORTHWEST E�TERIOR FI�TURE 'LF-02'
14 2400 640 WEST FRONT E�TERIOR FI�TURE 'LF-02'
15 2400 710 WEST FRONT E�TERIOR FI�TURE 'LF-02'
16 2400 580 WEST FRONT E�TERIOR FI�TURE 'LF-02'
17 2400 600 WEST FRONT E�TERIOR FI�TURE 'LF-02'
18 2400 970 WEST FRONT E�TERIOR FI�TURE 'LF-02'
19 2400 870 WEST FRONT E�TERIOR FI�TURE 'LF-02'
20 2400 1010 SOUTH WEST E�TERIOR FI�TURE 'LF-02'
21 2400 SPARE
22 2400 SPARE
23 2400 SPARE
24 2400 SPARE
25 2400 SPARE
26 2400 SPARE
27 2400 SPARE
28 2400 SPARE
29 2400 570 WEST FRONT E�TERIOR FI�TURE 'LF-01'
30 2400 620 WEST FRONT E�TERIOR FI�TURE 'LF-01'
31 2400 1030 SOUTH WEST E�TERIOR FI�TURE 'LF-01'
32 2400 SPARE
33 2400 1200 GAMING-THEME LTG FI�TURE 'LL-01' NON-DIM
34 2400 1390 GAMING-THEME LTG FI�TURE 'LL-01' NON-DIM
35 2400 1230 GAMING-THEME LTG FI�TURE 'LL-01' NON-DIM
36 2400 SPARE
37 2400 1330 GAMING GENERAL LTG FI�TURE 'L16' 0-10V
38 2400 1410 GAMING GENERAL LTG FI�TURE 'L16' 0-10V
39 2400 1410 GAMING GENERAL LTG FI�TURE 'L16' 0-10V
40 2400 1100 GAMING GENERAL LTG FI�TURE 'L16' 0-10V
41 2400 1330 GAMING GENERAL LTG FI�TURE 'L16' 0-10V
42 2400 SPARE SPARE
43 2400 300 MENS 24 �WOMENS 22 MIRROR LTG NON-DIM
44 2400 700 MENS 11 � WOMENS 13 MIRROR LTG NON-DIM
45 2400 960 ENTRY FI�TURE 'T1' TBD
46 2400 SPARE SPARE
47 2400 600 VESTIBULE FI�TURE 'LF-03' TBD
48 2400 SPARE SPARE
DESCRIPTION
800 A
LOAD
120/208V, 3Φ,4WINCOMING LINE�
WATTAGERATING
DIMMERNUMBER LOCATION
MAINS RATING�
LOAD
LOAD�
LOAD
96 MODULES
CHANNELCONTROL
RACK�
KVA30
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E0.30
DIMMER SCHEDULES
1 05/22/18 ADDENDUM #10
07/13/18 ADDENDUM #152
VESTIBULE00
LOBBY01
STORAGE08MARKETING
06IDF05
IDF OFFICE04
VESTIBULE03
PLAYERSCLUB
07
MENS VEST10
WOMENS VEST14
EVS STORAGE12
MENS11
WOMENS13
VESTIBULE103
Mens90
Womens92
BALLROOM96
BANQUETCORRIDOR
97
IDF27
BREAK OUT93
CONFERENCE28
MENS24
WOMENS22
MENS VEST23
WOMENS VEST20
EVS21
BEVERAGESTATION
19
SUPERVISOROFFICE
37
TRAP38
CART39A
CAGE MANAGER44
VAULT40
MAIN CAGE41
DROP AND ISSUE42 SHIFT
SUPERVISOR
47
CASHIEROFFICE
48
STO42A
OPERATIONMANAGER
30STO29
GENERALMANAGER
31MOD
32EVS STORAGE
33FIRE RISER
34EMERGENCYELECTRICAL
35
ELECTRICAL36 REVENUE AUDIT
46
AUDIT45 SURVEILLANCE
MANAGER
55 STO58
L&F57
SECURITYOFFICE
56
SECURITYSUPERVISOR
59
OFFICE62
WAITING61
KEY65
OFFICE63
OFFICE64
HOLDING66
SLOT MAINTENANCE67
TRASH68
IDF70
EVS75A
GAMINGCOMMISSION
71
SECURED STORAGE69A
EDR72
CORRIDOR26
GREEN54
STAIR53
MDF52
VIEWING49
CSA50
SURVEILLANCE51
CORRIDOR26
CORRIDOR26
CORRIDOR26
BEVERAGE STATION09
FJP25
BANQUETSTORAGE
99
WAITING86
DINING84
Bar85
PRIVATEDINING
83
BANQUETFOOD
PREPERATION
98
KITCHEN75
VIP EVENT76
GRAB AND GO15
LOUNGE16
BAR17
SERVINGSTATION
18
CASHIER43
KITCHEN79
CONNECTIONVESTIBULE
102
DRY STORAGE77
BO
H V
ES
TIB
ULE
60
EVS92A
EVS90A
PREFUNCTION89
GAMING02
MENS73
WOMENS74
TOILET88
TOILET87
OFFICE98A
EVS98B
WALKINC01
COOLERC02
COOLERC02
COOLERC03
COOLERC04
COOLERC05
RECIEVING69
ELE
CTR
ICA
L97
A
ELECTRICAL79B
DINING84A
CU
LTU
RE
102A
CU
LTU
RE
102B
CU
LTU
RE
103A
CU
LTU
RE
103B
CU
LTU
RE
00A
CU
LTU
RE
00B
FILE61B
OPEN AREA61A
ICE17A
BARSTORAGE
100
BREAK OUT94
BREAK OUT95
OFFICE78
OFFICE80
2
2
3
3
16
16
7
7
12
12
5
5
8
8
10
104
4 15
15
17
17
20
20
22
22
24
24
26
26
28
28
30
30
31
31
34
34
35
35
6
6 13
13
18
18
11
11
9
9
1
1
27
27
39
39
42
42 46
47
47
41
41
23
23
36
36
43
4319
19
14
14
25
25
32
32
21
21
37
37
40
40
45
45
38
38
29
29
33
33
D D
CC CC
Z Z
X X
T T
R R
M M
H H
EE EE
A A
C C
GGGG
FFFF
DD DD
B B
F F
N N
E E
Q
K K
J J
BB BB
AAAA
WW
PP
G
Y Y
V V
S S
L L
U U
HHHH
JJJJ
KKKK
LLLL
MMMM
NNNN
1000-TH-II
PANEL 'TCK4'
PANEL 'TCL3'PANEL 'TCL5'
PANEL 'TCMDF3'
PANEL 'TCU1'PANEL 'TCHLT1'
PANEL 'TCL4'PANEL 'TCL1'
PANEL 'TCMDF2'
PANEL 'TCMDF1'
GENERATOR ANNUNCIATOR
GENERATOR ANNUNCIATOR
FIRE ALARM ANNUNCIATOR
PANEL 'TCK3'
PANEL 'TCK2'PANEL 'TCK1'
PANEL 'TCL2'PANEL 'TCU2'
E3.1
EFS121
EFS122
EFS124
EFS124
E7.1
E7.1
E7.2
E7.3
E7.5
E7.6
E7.6
E7.4
PANEL 'TCEH'
PANEL 'TCIDF2'
PANEL 'TCIDF1'
PANEL 'TCCRM'
EFS120
EFS120
EFS120
PANEL 'TCHLT3'
EFS123
PANEL 'TCSHK7'PANEL 'TCSHK8'
PANEL 'TCSHK4'PANEL 'TCSHK5'
PANEL 'TCSHK6'
PANEL 'TCCCK3'
PANEL 'TCCCK4'PANEL 'TCCCK5'
PANEL 'TCCRM2'
3
3
3
3
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
BID PACKAGE 02(100% SET)
03/27/18 17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
E1.0
ELECTRICALOVERVIEW PLAN
A
NORTH
E1.0
ELECTRICAL OVERVIEW PLAN3/64" = 1'-0"
05/03/18 BID PACKAGE 051
05/22/18 ADDENDUM #102
07/13/18 ADDENDUM #153
VESTIBULE00
LOBBY01
STORAGE08MARKETING
06IDF05
IDF OFFICE04
VESTIBULE03
PLAYERSCLUB
07
MENS VEST10
WOMENS VEST14
EVS STORAGE12
MENS11
WOMENS13
BREAK OUT93
MENS24
WOMENS22
MENS VEST23
WOMENS VEST20
EVS21
BEVERAGESTATION
19
SUPERVISOROFFICE
37
TRAP38
CART39A
CAGE MANAGER44
VAULT40
MAIN CAGE41
DROP AND ISSUE42 SHIFT
SUPERVISOR
47
CASHIEROFFICE
48
STO42A
GREEN54
STAIR53
MDF52
VIEWING49
CSA50
SURVEILLANCE51
CORRIDOR26
CORRIDOR26
BEVERAGE STATION09
FJP25
GRAB AND GO15
LOUNGE16
BAR17
SERVINGSTATION
18
CASHIER43
GAMING02
CU
LTU
RE
00A
CU
LTU
RE
00B
BARSTORAGE
100
BREAK OUT94
BREAK OUT95
20 22 24 26 28
30 31
34 35
27
23
2532
21
37
38
29 33
CC
DD
Y
V
S
41
35
42
43
44
45
46
3434
33
37
39
36
3840
32
31
30
28
29
27
26
23
24
25
22
21
20
19
17
18 1612
09
11
15
13
10
14
07
05
06
08
04
03
02
01
1 1/4"C TOPANEL 'TCSP5'
1"EC
16
1614
14
2323
J 21 21
J J J J J J JJ J J J J J J
J
J
J
J J J
JJJJJJJJJJJJJJJJJJJJJ
TCL3-5 TCL3-15
25J
TCL3-25
25
25
TCL3-3 TCL3-13
J
TCL3-14 1
J
TCL3-21,23 1 J
TCL3-16�SPLIT CKT�
1
TCL3-1
TCL3-11
J
J
TCL3-33
TCL3-�35,37�
JJ
J J31
31 31
31
J
TCL3-31
2729
29
29
27
27
6 86
8
1010
12
J
TCL3-27,29 1
2
E3.3
14
14
4
4
2
J
TCL3-2
1
1
JTCL3-6,81
J
TCL3-41
22
22
16
8
6
8
6
TV20
18
1618
20
J
TCL2-18,201 22
J
TCL2-22 1
14J
TCL2-14,16
TV 24 J
TCL2-10,12
1
1
10
12
2
4
12 10
TCL2-2,41
J
TCL2-6,8 1
35
33
35
J
TCL2-33,35
30
1
TCL2-29
J
J
J
J J
J
J
J
TCL2-24
30
35
33TCL2-26
35
J
TCL2-301
30
13
115
J
TCU2-1,31
J
TCL2-51
13
19
25
25
25
6
4
8
10
12
16
18
2117
J
1
22
24
26
14 31
33
2 2
10
8
8
6
6
16
29 2
4
4 25
14 14
23
J
TCU2-7,91J
TCU2-251
12
12
15
1717TV
21 19
19
21
15 13
13
3
9
39
17
1
13
E3.3
5
11
5
11
91
7 7
J
TCU1-1,3,5 1
J
TCU1-13,15,17 1
J
TCU1-7,9,11
J
TCU1-19,211
J
TCL1-21 TCU1-6,8,10
JTCU1-12,14,161
1 1
J
TCU1-2,4 1
J
TCU2-8,10,12
23
1
J
TCU2-2,4,61
J
TCL3-10,121
TCL2-27
11333
5
55
5
7
7
7
7
999111111
13
13
15
15
1315
17
17
2325
2325
1921
1921
1921
2729
2729
46
46
46
2022
2022
810
810
810
2426
2426
2426
911
911
911
25
2527
27
25
2527
27
31
33
31
5
57
7
57
33
33
31
35
35
2123
2123
1513
1513
1513
1513
33
33
33
33
313131292929
35
2
2
77
7
5 55
3
111
33
21
2123
23
21
25
99
11
11911
4
42
2
2
4
35
1
319
3
3
11
3535
19
19
14
1416
16
1416
17
17
17
17
10
12
1012
22
2224
24
2224
30
30
32
32
3032
1313
1313
1517
1517
1919
1919
18
202020
1818
23
2321
21
21
25
2726
2726
2726
2022
2022
2022
1818
1818
55
55
2828
3030
28
30
14
14
14
14
16
16
16
16
32 32 32 34 34 3413 13 13 11 11 11
79
79
79
79
2626
2929
26
2922
22
22
22
24
24
24
24
1820
2018
141414161616
1
1
3
3
13
1212
1212
2424
2424
66
66
3333
3333
3535
3535
2727
2727
99
99
3030
2828
10
8
8
8
10
10
4
2
2
2
4
4
2
25
23
23
23
25
25
21
19
19
19
21
171717151515
10
12
12
12
10
10
J
29
31
29
31
29
31
24
24
24
57
57
57
30
32
30
32
30
32
6
8
68
6
88
6
33
11
3
1
28
28
26
26
28
26
3133
3133
3133
6
8
6
8
6
8
2929
2727
29
27
4 2
2
1820
1820
1820
26
28
26
28
26
28
1414
1616
14
16
10
10
12
12
10
12
1113
1113
1113
1517
1517
1618
1618
1618
1214
1214
1214
2424222222
6688
TCU2-17,19,21
1917 191919 610
16
2
227
27 25
25
23
23
20
28
�30
2
1197
5
�30�30�30
�30
5J
TCU2-11,131
J
TCU2-15,17 1
J
TCU1-25,27 1
J
TCU2-26,281
J
TCU2-14,16,18 1
J
TCU2-20,22,24 1
J
TCU1-29,31,331
J
19J
17J
9J
7JTCL3-17,191
JTCL3-7,9 1
TV
24
24TV
24TV
24TV
TV
20
JTCL5-241
TCSP1-32
J
TCL5-26 1
26TV
26TV
28TV
J
TCL5-281
30
TVJ
TCL5-30 1
30 TV TV30
TV30
TV
28
TV
28
22TV
22TV
JTCL5-221
20TV
41TV
20TVJ
TCL5-20 1
41TV
39TV
41TV
TV
39
TV
39
TV37
TV37
TV28
TV28
TV37
J
TCL2-37,39,411
22TVTV
TCSP4-36
TVJ
TCL2-28
28
1
TV J
4
4
4
12
4
1517
10
12
3838
34
34
34
34
23 21 17
121618
28
46
1
18
20
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
BID PACKAGE 02(100% SET)
03/27/18 17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
E1.1
ENLARGED POWERPLAN - GAMING
A
NORTH
E1.1
ENLARGED POWER PLAN - GAMING1/8" = 1'-0"
2' 16'8'4'0'
05/03/18 BID PACKAGE 051
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
1. VERIFY E�ACT LOCATION OF ALL OUTLETS WITH ARCHITECT PRIOR TO ROUGH-IN.
1
SHEET NOTES�
GENERAL NOTES�
05/22/18 ADDENDUM #102
06/01/18 ADDENDUM #113
07/13/18 ADDENDUM #154
GAMING LAYOUTREVISED
4
CONFERENCE28
44 SHIFT47
48
OPERATIONMANAGER
30STO29
GENERALMANAGER
31MOD
32EVS STORAGE
33FIRE RISER
34EMERGENCYELECTRICAL
35
ELECTRICAL36 REVENUE AUDIT
46
AUDIT45 SURVEILLANC
MANAGER
55
CORRIDOR26
CORRIDOR26
FJP25
2723
23
36
3625 32 37
C
F
K
J
J J
TV
17
J
TCL2-17,19 1
1917
25
TCL2-�13,15�
J
TCL2-5,7 1
77
5
�48"
�48" 5
9
9
9
11
J
TCL2-9,111
25
23
J
TCL2-23,25 1
16
1618
J
TCU2-16,18,20 1
20 20
2222
22 24
24
26 26
J
TCU2-22,24,261
PANEL 'TCU2'
PANEL 'TCL2'
GCEL-
GCEL-
20
28
18
20
18 28 26 2624 24 22 22
20
2032 32 30 30
J
TCU1-18,201
J
TCL4-24,26,28
J
TCL4-30,32
1
1J
TCL4-20,221
3432
38
34
36
36 J
TCL2-36,38 1
J
TCL2-32,34 1
2
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E1.1A
ENLARGED POWERPLAN - EAST
A
NORTH
E1.1A
ENLARGED POWER PLAN - EAST1/8" = 1'-0"
2' 16'8'4'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
1. REFER TO SHEET E1.0 FOR THE LOCATION OF PANEL 'TCU1' AND PANEL 'TCL4'.
2. VERIFY E�ACT LOCATION OF ALL OUTLETS WITH ARCHITECT PRIOR TO ROUGH-IN.
1
SHEET NOTES�
GENERAL NOTES�
06/01/18 ADDENDUM #111
07/13/18 ADDENDUM #152
CONFERENCE28
44 SHIFT47
48
OPERATIONMANAGER
30STO29
GENERALMANAGER
31MOD
32EVS STORAGE
33FIRE RISER
34EMERGENCYELECTRICAL
35
ELECTRICAL36 REVENUE AUDIT
46
AUDIT45 SURVEILLANCE
MANAGER
55 STO58
L&F57
SECURITYOFFICE
56
SECURITYSUPERVISOR
59
WA6
KE65
HOL6
CORRIDOR26
CORRIDOR26
FJP25
BO
H V
ES
TIB
ULE
60 FIL6
27
39
3923
23
36
3625 32 37 40
C
F
K
J
VAV
9-9
CH
1
VAV
9-13
MAIN SERVICE SWITCHBOARD 'TCMSA'
S35 S35
J
#10TCL4-351
F800/3WP
MAIN SERVICE SWITCHBOARD 'TCMSA-9' 2
FC
6
F
TCCRM2-�7,9,11�
FC
5
F
TCCRM2-�1,3,5�
FC
7
FTCCRM2-�13,15,17�
2CH
2A
F800/3WP
MAIN SERVICE SWITCHBOARD 'TCMSB-3' 2
CH
2B
F600/3WP
MAIN SERVICE SWITCHBOARD 'TCMSB-8' 2
CH
3A
F800/3WP
MAIN SERVICE SWITCHBOARD 'TCMSB-11' 2
CH
3B
F600/3WP
MAIN SERVICE SWITCHBOARD 'TCMSB-12' 2
2
2
2
VAV
9-2
S35
2
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E1.1AM
ENLARGEDMECHANICAL POWER
PLAN - EAST
A
NORTH
E1.1AM
ENLARGED MECHANICAL POWER PLAN - EAST1/8" = 1'-0"
2' 16'8'4'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
REFER TO SHEET E0.10 FOR ADDITIONAL RE�UIREMENTS.
1. VERIFY E�ACT LOCATION OF ALL MECHANICAL E�UIPMENT WITH MECHANICALCONTRACTOR PRIOR TO ROUGH-IN.
1
SHEET NOTES�
GENERAL NOTES�
2
05/22/18 ADDENDUM #101
07/13/18 ADDENDUM #152
VESTIBULE00
LOBBY01
STORAGE08MARKETING
06IDF05
IDF OFFICE04
VESTIBULE03
PLAYERSCLUB
07
MENS VEST10
WOMENS VEST14
EVS STORAGE12
MENS11
WOMENS13
BREAK OUT93
MENS24
WOMENS22
MENS VEST23
WOMENS VEST20
EVS21
BEVERAGESTATION
19
SUPERVISOROFFICE
37
TRAP38
CART39A
CAGE MANAGER44
VAULT40
MAIN CAGE41
DROP AND ISSUE42 SHIFT
SUPERVISOR
47
CASHIEROFFICE
48
STO42A
OPERATIONMANAGER
30STO29
GENERALMANAGER
31MOD
32EVS STORAGE
33FIRE RISER
34EMERGENCYELECTRICAL
35
ELECTRICAL36 REVENUE AUDIT
46
AUDIT45 SURVEILLANCE
MANAGER
55 STO58
L&F57
SECUOFF
5
SESUP
GREEN54
STAIR53
MDF52
VIEWING49
CSA50
SURVEILLANCE51
CORRIDOR26
CORRIDOR26
CORRIDOR26
BEVERAGE STATION09
FJP25
BANQUETSTORAGE
99
GRAB AND GO15
LOUNGE16
BAR17
SERVINGSTATION
18
CASHIER43
GAMING02
CU
LTU
RE
00A
CU
LTU
RE
00B
BARSTORAGE
100
BREAK OUT94
BREAK OUT95
20 22 24 26 28
30 31
34 35
27
39
23
36
2532
21
37
38
29 33
CC
DD
Y
V
S
L
FC
3
FC
2
FC
4
VAV
9-11
VAV
9-10
VAV
9-8
VAV
9-12
VAV
9-7
VAV
9-6
VAV
9-5
VAV
9-5
VAV
9-3
VAV
9-4
VAV
9-1
VAV
5-3
VAV
5-4
VAV
5-5
S33
J
#10TCL4-331
S33
S33
S33
S33
S33
S31
J
#10
TCL4-31 1
S31
S31S31
F
#10
TCHLT3-�14,16,18�
F
#10
TCHLT3-�8,10,12�
F
#10
TCHLT3-�2,4,6�
S31
S31
S31
WS
1
S
TCL3-36PANEL 'TCL3'
WH
2
SWH
1
S
J
TCL3-38,38,401
38 40
CP
1
S42
2
F
#10
TCCRM-�31,33,35�
2
2
2
2
2
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E1.1M
ENLARGEDMECHANICAL POWER
PLAN - GAMING
A
NORTH
E1.1M
ENLARGED MECHANICAL POWER PLAN - GAMING1/8" = 1'-0"
2' 16'8'4'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
NOTE DELETED.
1. VERIFY E�ACT LOCATION OF ALL MECHANICAL E�UIPMENT WITH MECHANICALCONTRACTOR PRIOR TO ROUGH-IN.
1
SHEET NOTES�
GENERAL NOTES�
2
05/22/18 ADDENDUM #101
07/13/18 ADDENDUM #152
2
WOMENS VEST14
MENS3
OFFICE64
HOLDING66
SLOT MAINTENANCE67
IDF70
EVS75A
GAMINGCOMMISSION
71
SECURED STORAGE69A
EDR72
CORRIDOR26
GREEN54
STAIR53
MDF52
VIEWING49
CSA50
SURVEILLANCE51
WAITING86
DINING84
Bar85
PRIVATEDINING
83
KITCHEN75
VIP EVENT76
GRAB AND GO15
LOUNGE16
BAR17
SERVINGSTATION
18
KITCHEN79
CONNECTIONVESTIBULE
102
DRY STORAGE77
MENS73
WOMENS74
TOILET88
TOILET87
COOLERC03
COOLERC04
COOLERC05
ELECTRICAL
DINING84A
CU
LTU
RE
102A
CU
LTU
RE
102B
ICE17A
BARSTORAGE
100
OFFICE78
OFFICE80
41 43
3740 45
38
EE
FF
BB
U
1000-TH-II
120V-1PH, 1.9KW
15
17 15
17
2323
23
19 21
212TYP 4
JTCL5-19,21,231
19
JTCL5-15,171
21
23
19
25
3028
11
3 3
34
11
11
9
13
139
TVJ TCL5-9,11,13 1
J
32J
32
3028
3028
J
TCL3-28,30,321
34
1
1
1
7
5
TV57
J TCL5-1,3 1 J
TCL5-5,71
J
TCL3-34 125
2626
J J
J J
TCL3-18TCL3-20
JTCL3-26 1
J
TCL3-16�SPLIT CKT�
1
46
4
2
29
27
J
TCL4-27,29 1
J
TCL4-4,6 1
JJJJ
JJJJ
13
13
2
1
7
TCL4-1,31 3
9
E3.3
2J
TCL4-2 1
19
TV
1717
23
23
19
TV
15
15
TV15
J
TCL4-15,17 1
JTCL4-19,21,231
16
168 1012
23
J
TCL4-13 1TCL4-7,91
J
14
18
S
J
TCL4-8,10,12 1
JTCL4-14,16,18 1
J
26
S
36
36 JTCL4-36 1
19
27
44
66
88
1010
1014
14
12
12
18
18
16
16
14
35
J
J35
J
TCL5-4,6,8 1
TCL1-35
J TCL5-10,12,14 1
J
TCL5-16,181
4
6
6
TCL5-39
35
35
37 J
TCL5-35,371
313133
J
TCL5-31,33 1
TCL5-27
TCL5-29
47
36 36 36343434
3
4
27
27
3
3
3
3
7
3
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E1.2
ENLARGED POWERPLAN - SOUTH
A
NORTH
E1.2
ENLARGED POWER PLAN - SOUTH1/8" = 1'-0"
2' 16'8'4'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
RECEPTACLE TO BE INSTALLED IN THE MILLWORK. COORDINATE RECEPTACLE LOCATIONAND INSTALLATION WITH THE MILLWORK CONTRACTOR PRIOR TO ROUGH-IN.
PROVIDE RECEPTACLE FOR STAGE PROJECTOR. COORDINATE RECEPTACLE LOCATIONAND INSTALLATION RE�UIREMENTS WITH THE AV CONTRACTOR PRIOR TO ROUGH-IN.
PROVIDE POWER CIRCUIT FOR PROJECTOR SCREEN. COORDINATE JUNCTION BO�LOCATION WITH THE AV CONTRACTOR PRIOR TO ROUGH-IN.
PROVIDE RECEPTACLES FOR SOUND BOOTH. COORDINATE RECEPTACLE LOCATIONSWITH THE AV CONTRACTOR PRIOR TO ROUGH-IN.
PROVIDE RECEPTACLES FOR VIDEO WALL. COORDINATE RECEPTACLE LOCATIONS,MOUNTING HEIGHTS AND INSTALLION RE�UIREMENTS WITH THE AV CONTRACTORPRIOR TO ROUGH-IN.
JUNCTION BO� TO SERVE POWER RE�UIREMENTS FOR LIFT STATION.
1. VERIFY E�ACT LOCATION OF ALL OUTLETS WITH ARCHITECT PRIOR TO ROUGH-IN.
1
SHEET NOTES�
GENERAL NOTES�
2
05/22/18 ADDENDUM #101
06/01/18 ADDENDUM #112
3
4
5
6
07/13/18 ADDENDUM #153
73
WOMENS VEST14
MENS3
OFFICE64
HOLDING66
SLOT MAINTENANCE67
IDF70
EVS75A
GAMINGCOMMISSION
71
SECURED STORAGE69A
EDR72
CORRIDOR26
GREEN54
STAIR53
MDF52
VIEWING49
CSA50
SURVEILLANCE51
WAITING86
DINING84
Bar85
PRIVATEDINING
83
KITCHEN75
VIP EVENT76
GRAB AND GO15
LOUNGE16
BAR17
SERVINGSTATION
18
KITCHEN79
CONNECTIONVESTIBULE
102
DRY STORAGE77
MENS73
WOMENS74
TOILET88
TOILET87
COOLERC03
COOLERC04
COOLERC05
ELECTRICAL
DINING84A
CU
LTU
RE
102A
CU
LTU
RE
102B
ICE17A
BARSTORAGE
100
OFFICE78
OFFICE80
41 43
3740 45
38
EE
FF
BB
U
1000-TH-II
120V-1PH, 1.9KW
FC
1
VAV
4-6
VAV
4-5
VAV
4-4
VAV
4-3
VAV
4-1
VAV
4-7
VAV
4-11
VAV
4-10
FC
9
VAV
4-12
VAV
4-8
VAV
4-9
VAV
10-7
VAV
10-6
VAV
10-5
VAV
10-4
F
#10
TCSHH1-�1,3,5�
S1
S1
S1
S1
S1
S3
S3
S3
S3
J
TCSHL1-1,3 1
S5
J
TCSHL1-5 1
S5
S5
S5
S5
S5
PANEL 'TCSHL1'PANEL 'TCSHH1'
F
TCCRM-�19,21,23�1
F100/3
TCCRM-�1,3,5�22
2
2
2
VAV
4-2
S3
2
2
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E1.2M
ENLARGEDMECHANICAL POWER
PLAN - SOUTH
A
NORTH
E1.2M
ENLARGED MECHANICAL POWER PLAN - SOUTH1/8" = 1'-0"
2' 16'8'4'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
1 1/4"C - 3#4, 1#8 GND.
1. VERIFY E�ACT LOCATION OF ALL MECHANICAL E�UIPMENT WITH MECHANICALCONTRACTOR PRIOR TO ROUGH-IN.
1
SHEET NOTES�
GENERAL NOTES�
05/22/18 ADDENDUM #10
2
1
2
07/13/18 ADDENDUM #15
AUDIT45 SURVEILLANCE
MANAGER
55 STO58
L&F57
SECURITYOFFICE
56
SECURITYSUPERVISOR
59
OFFICE62
WAITING61
KEY65
OFFICE63
OFFICE64
HOLDING66
SLOT MAINTENANCE67
TRASH68
IDF70
EVS75A
GAMINGCOMMISSION
71
SECURED STORAGE69A
EDR72
CORRIDOR26
GREEN54
STAIR53
MDF52
VIEWING49
CSA50
SURVEILLANCE51
83
LOUNGE16
BAR17
SERVINGSTATION
18
KITCHEN79
BO
H V
ES
TIB
ULE
60
MENS73
WOMENS74
COOLERC03
RECIEVING69
ELECTRICAL79B
FILE61B
OPEN AREA61A
ICE17A
BARSTORAGE
100
OFFICE78
39
39
42
42 46 47
36
36 37 40 45
N
E E
Q
K K
U
1000-TH-II
120V-1PH, 1.9KW
8
8
8
26
12
12
TCL1-�20,22�
TCL1-�16,18�
JTCL1-12,141
J
TCL1-8 1
DOOR
2J
2
TCL1-6
DOOR
1J
2
TCL1-4
24J
TCL1-24,26 1
14
28
14
J
TCL1-281
7
573
1
3
51
9 19
WP
28WP
29
3127 2925
25 3127
19
1799 17
11
1121
23
21
23 21
23
15 1315
13
J
J
TCL1-5,71
TCL1-1,3 1
J
TCL1-17,19 1
J TCL1-9,11 1
J
TCL1-13,151
�60"
J
TCL1-21,23 1
J
TCL1-29,31 1J
TCL1-25,27 1
10
26
34
36
34
2
28
30
3638
24
TV24
10
26
J
TCL1-28,30,321
J TCL1-10 1
J
TCL1-24,261
J
TCL1-34,36,381
32
PANEL 'TCL1'
E3.2J
32J
32
3
J
TCL1-32 1
TCL1-36
34
34
J
TCL1-34 1
2
2
2
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E1.3
ENLARGED POWERPLAN - BOH
A
NORTH
E1.3
ENLARGED POWER PLAN - BOH1/8" = 1'-0"
2' 16'8'4'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
CONNECT TO OVERHEAD DOOR, AND UP/DOWN CONTROLS PER MANUFACTURER'SINSTALLATION DRAWINGS.
PROVIDE RECEPTACLE FOR TIME CLOCK. COORDINATE RECEPTACLE LOCATION ANDINSTALLATION HEIGHT WITH THE OWNER PRIOR TO ROUGH-IN.
1. VERIFY E�ACT LOCATION OF ALL OUTLETS WITH ARCHITECT PRIOR TO ROUGH-IN.
1
SHEET NOTES�
GENERAL NOTES�
2
3
06/01/18 ADDENDUM #111
07/13/18 ADDENDUM #152
AUDIT45 SURVEILLANCE
MANAGER
55 STO58
L&F57
SECURITYOFFICE
56
SECURITYSUPERVISOR
59
OFFICE62
WAITING61
KEY65
OFFICE63
OFFICE64
HOLDING66
SLOT MAINTENANCE67
TRASH68
IDF70
EVS75A
GAMINGCOMMISSION
71
SECURED STORAGE69A
EDR72
CORRIDOR26
GREEN54
STAIR53
MDF52
VIEWING49
CSA50
SURVEILLANCE51
83
LOUNGE16
BAR17
SERVINGSTATION
18
KITCHEN79
BO
H V
ES
TIB
ULE
60
MENS73
WOMENS74
COOLERC03
RECIEVING69
ELECTRICAL79B
FILE61B
OPEN AREA61A
ICE17A
BARSTORAGE
100
OFFICE78
39
39
42
42 46 47
36
36 37 40 45
N
E E
Q
K K
U
1000-TH-II
120V-1PH, 1.9KW
FC
8
VAV
10-9
VAV
10-8
HUH
1
HUH
2
HUH
3
HUH
4
MCP
1
VAV
10-3
VAV
10-1
VAV
10-2
PANEL 'TCSHL1'
F
TCSHH1-�31,33,35�
S13
J
TCSHL1-131
S13
S13S13
S13
F400/3WP
MAIN SERVICE SWITCHBOARD 'TCMSA-10'215 17 19 21
J
TCSHL1-15,171
J
TCSHL1-19,211
PANEL 'TCSHH1'
FC
11
F
EF
7
TCSHL1-7
TCCRM2-�2,4,6�
2
2
2
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E1.3M
ENLARGEDMECHANICAL POWER
PLAN - BOH
A
NORTH
E1.3M
ENLARGED MECHANICAL POWER PLAN - BOH1/8" = 1'-0"
2' 16'8'4'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
REFER TO SHEET E0.10 FOR ADDITIONAL RE�UIREMENTS.
1. VERIFY E�ACT LOCATION OF ALL MECHANICAL E�UIPMENT WITH MECHANICALCONTRACTOR PRIOR TO ROUGH-IN.
1
SHEET NOTES�
GENERAL NOTES�
2
05/22/18 ADDENDUM #101
07/13/18 ADDENDUM #152
BANQUETCORRIDOR
97
IDF27
C
24
OPERATIONMANAGER
30
GENERALMANAGER
31
CORRIDOR26
FJP25
BANQUETSTORAGE
99
BANQUETFOOD
PREPERATION
98OFFICE
98A
EVS98B
WALKINC01
COOLERC02
COOLERC02
ELE
CTR
ICA
L97
A
BREAK OUT95
7 12119
23
23
25
21
D
R
M
H
A
B
F
N
J
P
S S
L L
SIGN
S26
SIGNS28
SIGN
28S
E3.3
SIGNS32
SIGN
32S
SIGN
S34
TCCCL2-34�SPLIT CKT�
SIGN
S30
SIGN
S30
8
1
3
3
3
1
TCCCL2-29
248
15TV
24
JTCCCL2-281
TCCCL2-26�SPLIT CKT�
1 J
TCL2-1 1
13
21
9
31
5
23
1
27
J
TCCCL1-13,151
J
TCCCL1-9,111
J
TCCCL1-1,31
J
TCCCL1-5,7 1
22
66 11
TVJ
TCCCL1-6,8 1
DOOR
CC-1
TCCCL2-31
DOOR
CC-2
TCCCL2-33
22 J
TCCCL1-22,24 120201818 J
TCCCL1-18,20 1
223
TV19
4
35
35
J
TCCCL1-35 1
4
7TV
19
J
TCCCL2-19 1
J
TCCCL2-30,32 1
J
TCCCL1-2,41
JTCL2-3 1
VAV
5-1
S1
J TCCCL3-1 1
PANEL 'TCCCL3'
PANEL 'TCCCL1'
PANEL 'TCCCL2'
PANEL 'TCL2'
E3.2
PANEL 'TCCRM'
PANEL 'TCHLT2'
19
FC
9F
TO DISTRIBUTION SWITCHBOARD 'TCCHDB-9'
2TYP
F N
33
COMPANY SWITCH 'CSPA'
TO DISTRIBUTIONPANELBOARD 'TCCCLDB'
COMPANY SWITCH 'CSLTG'
�FMR 'TCCSPA' 4
5
J4
J4
J2
J2
J
TCCCL3-4 16
J
TCCCL3-21
J
TCCCL3-19
J31
5
7
J
TCCCL3-31 129
J29
5
7
J
TCCCL3-29
33J
33
5
7
J
TCCCL3-33
J21
5
7
J
TCCCL3-21
25J
25
5
7
J
TCCCL3-25 1
1
1
1
J
7
27
J
TCCCL3-27 1
J
TCCCL3-17
J23
5
7
J
TCCCL3-23 1
3
CRAC
3F TCCRM-�13,15,17�
3
3
VAV
1-4
S38
J
TCCCL3-38,40 1
VAV
1-1
S38
VAV
1-2
S38VAV
1-3
S38
VAV
1-5
S40
VAV
1-6
S40
VAV
1-7
S40
3
VAV
5-2
S1
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E1.4
ENLARGED POWERPLAN - BANQUET BOH
A
NORTH
E1.4
ENLARGED POWER PLAN - BAN�UET BOH1/8" = 1'-0"
2' 16'8'4'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
PROVIDE JUNCTION BO� FOR CONNECTION TO DOOR HOLDERS AND CONNECT PERINSTALLED E�UIPMENT SHOP DRAWINGS. PROVIDE ALL NECESSARY POWER ANDCONTROL CONDUIT AND WIRING FOR A COMPLETE AND OPERABLE SYSTEM.
PROVIDE CIRCUIT AND SAFETY SWITCH FOR COMPANY SWITCH. COORDINATE SWITCHLOCATION AND INSTALLATION RE�UIREMENTS WITH THE AV CONTRACTOR PRIOR TOROUGH-IN.
TRANSFORMER TO BE WALL MOUNTED ABOCE SUSPENDED CEILING. COORDINATETRANSFORMER LOCATION WITH THE COMPANY SWITCH 'CSPA' LOCATION AND WITHTHE AV CONTRACTOR PRIOR TO ROUGH-IN. ALL NECESSARY MOUNTING BRACKETS,HARDWARE FOR A SAFE PROFESSIONAL INSTALLATION. CONFORM WITH TRANSFORMERMANUFACTURER STRUCTURAL AND INSTALLATION RE�UIREMENTS.
PROVIDE CEILING MOUNTED RECEPTACLE FOR PROJECTOR. COORDINATE RECEPTACLELOCATION AND INSTALLATION RE�UIREMENTS WITH THE AV CONSULTANT PRIOR TOROUGH-IN.
PROVIDE CONNECTION TO PROJECTOR SCREEN COORDINATE CONNECTION LOCATIONAND INSTALLATION RE�UIREMENTS WITH THE AV CONSULTANT PRIOR TO ROUGH-IN.
PROVIDE CONNECTION TO PROJECTOR LIFT COORDINATE CONNECTION LOCATION ANDINSTALLATION RE�UIREMENTS WITH AV CONSULTANT PRIOR TO ROUGH-IN.
1. VERIFY E�ACT LOCATION OF ALL OUTLETS WITH ARCHITECT PRIOR TO ROUGH-IN.
1
SHEET NOTES�
GENERAL NOTES�
2
05/22/18 ADDENDUM #101
06/01/18 ADDENDUM #112
3
4
5
6
7
07/13/18 ADDENDUM #153
VESTIBULE103
Mens90
Womens92
BALLROOM96
BREA9
EVS92A
EVS90A
PREFUNCTION89
CU
LTU
RE
103A
CU
LTU
RE
103B
BREAK O94
BREAK O95
3 167 125
8 104
15
17 20
6 13
14
Z
X
T
BB
AA
W
Y
V
S
U
2525
18
34
27
27
34
36
36
SIGNS26
TCCCL2-26�SPLIT CKT�
SIGNS24
SIGNS24
14
27TV
JTCCCL1-14,161
323233
25
25
32
29
30
21
28
17
26
J
TCCCL1-29,311J
TCCCL1-21,23 1
J
TCCCL1-17,19 1J
TCCCL1-25,271
J
TCCCL2-241
14
16
TV3116
333030
12
TV2312
J
TCCCL1-30,32 1
10
10
19TV
JTCCCL1-10,12 1
J
TCCCL1-34,36
SIGN
22SSIGN
22S
21
21
28
28
26
26
J
TCCCL1-26,28 1
SIGNS
TCCCL2-34�SPLIT CKT�
SIGNS20
J
TCCCL2-21,23 1
SIGNS20
J
TCCCL2-20,22 1
J
TCCCL1-33 1
1
2323
J J J J J J J J J J J J J J J J J J J J J J J J J
17 18
38
38
36
36
37
37
35
35
17 1817
TCCCL2-4TCCCL2-2
J39
J39
J
TCCCL2-25,271
JTCCCL2-36,381
JTCCCL2-35,37 1
J
TCCCL2-39,41 1
J41
J41
JTCCCL2-18 1
TCCCL2-3TCCCL2-1
JTCCCL2-17 1
TCCCL2-7TCCCL2-5 TCCCL2-8TCCCL2-6
40 4040 40 J
TCCCL2-40 1
J
J J
J
4TYP. 4
J9
J
TCCCL2-9,11 1
J11
J13
J15
JTCCCL2-13,15 1
J10
J 12 J14
J16
J
TCCCL2-10,12 1
J
TCCCL2-14,161
TCCCL3-20
TCCCL3-18
J
2
3
TCCCL3-22
TCCCL3-24
30J
TCCCL3-301
J
3
28J
TCCCL3-28 12
J
2
3
32J
TCCCL3-321
36TV
J
TCCCL3-361
J
3
26J
TCCCL3-26 12
34TVJ
TCCCL3-34 1
TV36
TV34
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E1.5
ENLARGED POWERPLAN - NORTH
A
NORTH
E1.5
ENLARGED POWER PLAN - NORTH1/8" = 1'-0"
2' 16'8'4'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
PROVIDE CEILING MOUNTED RECEPTACLE FOR PROJECTOR. COORDINATE RECEPTACLELOCATION AND INSTALLATION RE�UIREMENTS WITH THE AV CONSULTANT PRIOR TOROUGH-IN.
PROVIDE CONNECTION TO PROJECTOR LIFT COORDINATE CONNECTION LOCATION ANDINSTALLATION RE�UIREMENTS WITH THE AV CONSULTANT PRIOR TO ROUGH-IN.
ROVIDE CONNECTION TO PROJECTOR SCREEN COORDINATE CONNECTION LOCATIONAND INSTALLATION RE�UIREMENTS WITH THE AV CONSULTANT PRIOR TO ROUGH-IN.
1. VERIFY E�ACT LOCATION OF ALL OUTLETS WITH ARCHITECT PRIOR TO ROUGH-IN.
1
SHEET NOTES�
GENERAL NOTES�
05/22/18 ADDENDUM #101
06/01/18 ADDENDUM #112
2
3
4
07/13/18 ADDENDUM #153
ARCHITECTURALBACKGROUND
REVISED3
VESTIBULE103
Mens90
Womens92
BALLROOM96
BREA9
EVS92A
EVS90A
PREFUNCTION89
CU
LTU
RE
103A
CU
LTU
RE
103B
BREAK O94
BREAK O95
3 167 125
8 104
15
17 20
6 13
14
Z
X
T
BB
AA
W
Y
V
S
U
VAV
5-12
VAV
5-11
VAV
5-10
VAV
5-9
VAV
5-8
VAV
5-6
S5
S5
S3
S3
S3
S3
J
TCCCL3-5,7 1
1
VAV
5-7
S5 1
FC
12
F30/3
TCHLT2-�14,16,18�
1
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E1.5M
ENLARGEDMECHANICAL POWER
PLAN - NORTH
A
NORTH
E1.5M
ENLARGED MECHANICAL POWER PLAN - NORTH1/8" = 1'-0"
2' 16'8'4'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
1. VERIFY E�ACT LOCATION OF ALL MECHANICAL E�UIPMENT WITH MECHANICALCONTRACTOR PRIOR TO ROUGH-IN.
1
SHEET NOTES�
GENERAL NOTES�
07/13/18 ADDENDUM #151
2
2
3
3
16
16
7
7
12
12
5
5
8
8
10
104
4 15
15
17
17
20
20
22
22
24
24
26
26
28
28
30
30
31
31
34
34
35
35
6
6 13
13
18
18
11
11
9
9
1
1
27
27
39
39
42
42
46
46
47
47
41
41
23
23
36
36
43
4319
19
14
14
25
25
32
32
21
21
37
37
40
40
45
45
38
38
29
29
33
33
D D
CC CC
Z Z
X X
T T
R R
M M
H H
EE EE
A A
C C
GGGG
FFFF
DD DD
B B
F F
N N
E E
Q Q
K K
J J
BB BBAAAA
WW
PP
GG
Y Y
V V
S S
L L
HHHH
JJJJ
KKKK
LLLLMMMM
NNNN
AHU
4
DISTRIBUTION PANEL 'TCMHDB1-6'
AHU
10
AHU
8
AHU
9
AHU
7
AHU
6
DISTRIBUTION PANEL 'TCMHDB1'
AHU
3
AHU
5
AHU
2
AHU
1
MAU
1
F
F
DISTRIBUTION PANEL 'TCMHDB2-6'
KEF
4
KEF
3
F
DISTRIBUTION PANEL 'TCMHDB2-3'
KEF
5
KEF
6
EF
3
EF
2
CCU
1
F
DISTRIBUTION PANEL 'TCMHDB2-5'
F
DISTRIBUTION PANEL 'TCMHDB2-4'
F
DISTRIBUTION PANEL 'TCMHDB2-2'
EF
6
F
DISTRIBUTION PANEL 'TCMHDB2-1'
KEF
2
KEF
1
MAU
2
F
DISTRIBUTION PANEL 'TCMHDB1-1'
F
DISTRIBUTION PANEL 'TCMHDB1-2'
F
DISTRIBUTION PANEL 'TCMHDB1-3'
F
DISTRIBUTION PANEL 'TCMHDB1-4'
EF
4
EF
5
WP
TCL4-37
EF
1
WP
TCHLT3-�20,22,24�
WP
#10TCSHH1-�13,15,17�
WP
TCSHH1-�7,9,11�
#10WP
TCSHL1-11
WP
TCSHH1-�19,21,23�
WP
TCSHH1-�25,27,29�
WP
TCSHL1-9
WPTCHLT2-�2,4,6�
WP
TCHLT2-�8,10,12�
WP
TCCCL3-7
WP
TCCCL3-9
2
2
WP4
WP4
WP4WP4
WP22WP2
WP2
J
TCSHL1-2,4 1
2
WP39
2
WP39
2
WP39
JTCL4-39 1
2
WP13
WP13
WP13
2
2
2
WP13
WP13
J
TCCCL3-131
F
DISTRIBUTION PANEL 'TCMHDB1-5' 2
2
WP11WP11
WP11
J
TCCCL3-11 1
F WP
TCCRM-�2,4,6�
CCU
2A
CCU
2B
F F
TCCRM-�8,10,12�WP WP
TCCRM-�14,16,18�
1
1
CCU
3
WP39F
TCCRM-�20,22,24�
WP
1DISTRIBUTION PANEL 'TCMHDB2'
1
1
1
1
1
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E1.6
POWER PLAN - ROOF
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
REFER TO SHEET E0.12 FOR ADDITIONAL RE�UIREMENTS.
1. VERIFY E�ACT LOCATION OF ALL MECHANICAL E�UIPMENT WITH MECHANICALCONTRACTOR PRIOR TO ROUGH-IN.
1
SHEET NOTES�
GENERAL NOTES�
A
NORTH
E1.6
POWER PLAN - ROOF1" = 20'-0"
5' 40'20'10'0'
2
07/13/18 ADDENDUM #151
STORAGE33
FIRE RISER34
EMERGENCYELECTRICAL
35
ELECTRICAL36 REVENUE AUDIT
46
CORRIDOR26
F
J
DISTRIBUTION PANEL 'TCLUPS1'
�FMR 'TTCLUPS1'
DISTRIBUTION PANEL 'TCHUPS1'
UPS 'TCUPS1'
DISTRIBUTION PANEL 'TCLDB'
�FMR 'TTCLDB'
�FMR 'TTCEL'
PANEL 'TCEL'
PANEL 'TCEH'
UPS 'TCUPS2'
PANEL 'TCSP3/4'
DIMMER PANEL 'TCDRN'
UPS1 MAINTENANCE BYPASS PANELBOARD
PANEL 'TCLUPS2'
ATS #2
UPS2 MAINTENANCE BYPASS PANELBOARD
MAIN SERVICE SWITCHBOARD 'TCMSA' MAIN SERVICE SWITCHBOARD 'TCMSB'
UTILITY COMPANY �FMR 'A' UTILITY COMPANY �FMR 'B'
EMERGENCY GENERATOR 'TCEGA'
PANEL 'TCSP1/2'DIMMER PANEL 'TCDRE'
FIRE ALARM PANELPANEL 'TCSP5'
2
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
BID PACKAGE 02(100% SET)
03/27/18 17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
E3.1
ENLARGEDELECTRICAL ROOM
PLAN
A
NORTH
E3.1
ENLARGED ELECTRICAL ROOM PLAN1/4" = 1'-0"
1' 8'4'2'0'
05/03/18 BID PACKAGE 051
07/13/18 ADDENDUM #152
ELE
CTR
ICA
L97
A
DISTRIBUTION PANEL 'TCCCLDB'
PANEL 'TCHLT2'
�FMR 'TTCCCLDB'
PANEL 'TCCCL1'
PANEL 'TCCCL2'
PANEL 'TCCCL3'PANEL 'TCCCK1'
PANEL 'TCCCK2'
ELTS PANEL 'TCCCDRE'
TRIBUTION SWITCHBOARD 'TCCCHDB'
DIMMER PANEL 'TCCCDRN' URED STORAGE69A
ELECTRICAL79B PANEL 'TCSHK1'
PANEL 'TCSHK2'
PANEL 'TCSHK3'
�FMR 'TTCSHLDB'
DISTRIBUTION PANEL 'TCSHHDB'
DISTRIBUTION PANEL 'TCSHLDB'
PANEL 'TCSHH1'PANEL 'TCSHL1'
3
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
BID PACKAGE 02(100% SET)
03/27/18 17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
E3.2
ENLARGEDELECTRICAL ROOM
PLANS
A
NORTH
E3.2
ENLARGED ELECTRICAL ROOM PLAN1/4" = 1'-0"
1' 8'4'2'0'
B
NORTH
E3.2 1/4" = 1'-0"1' 8'4'2'0'
ENLARGED ELECTRICAL ROOM PLAN
05/03/18 BID PACKAGE 051
05/22/18 ADDENDUM #102
07/13/18 ADDENDUM #153
MARKETING06
IDF05
VESTIBULE
PLAYERCLUB
07
24 26
PANEL 'TCIDF3'
2
J
TCL5-21
#10
2
J
TCIDF3-�1,3,5�
8
7
IDF27
H
F
J
L L
PANEL 'TCIDF2'37
J
TCCCL1-37 1
#10
37
J
TCIDF2-�1,3,5�
8
7
IDF70
GAMINGCOMMISSION
71MENS
73
OFFICE78
PANEL 'TCIDF1'
J
J6
J
1
#10
6
TCSHL1-6
5TYP 6
11
7
5
3
TCIDF1-5,7 1
TCIDF1-1,31
#10TCIDF1-13
1
TCIDF1-9,11 1#10
#10
9
J
#10
2
STAIR53
MDF52
SURVEILLANCE51
SERVINGSTATION
18
21252622
23212824
J
TCMDF2-21,23
JJ
TCMDF1-22,24
JJ
TCEL-1
TCEL-3
PANEL 'TCMDF1'
PANEL 'TCMDF2'
J
1
TCMDF2-25,27 1
1
TCMDF1-26,281
1920
1920
J
TCMDF1-201
�72"
�60"
�72"
�60"
J
TCMDF2-19 1
J
J
7TYP. 4
TCMDF1-�1,3,5�
8
TCMDF1-�2,4,6�
J
J
TCMDF1-�7,9,11�
8
TCMDF1-�8,10,12�
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E3.3
ENLARGED PLANS
C
NORTH
E3.3
ENLARGED IDF ROOM PLAN1/4" = 1'-0"
1' 8'4'2'0'
D
NORTH
E3.3 1/4" = 1'-0"1' 8'4'2'0'
ENLARGED IDF ROOM PLAN
A
NORTH
E3.3
ENLARGED MDF ROOM PLAN1/4" = 1'-0"
1' 8'4'2'0'
B
NORTH
E3.3 1/4" = 1'-0"1' 8'4'2'0'
ENLARGED IDF ROOM PLAN
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
NOTE DELETED.
NOTE DELETED.
NOTE DELETED.
PROVIDE L5-30R RECEPTACLE. MOUNT BELOW RAISED FLOOR ABOVE GROUND ONSUPPORT. COORDINATE INSTALLATION LOCATION AND RE�UIREMENTS WITH ITMANUFACTURER PRIOR TO ROUGH-IN.
NOTE DELTED.
PROVIDE TRACK BUSWAY �STARLINE #B60-20-4 FOR MDF52, B60-�0-4 FOR IDF 05 ANDB60-5-4 FOR IDF 27�. PROVIDE ALL NECESSARY BUSWAY PARTS �SECTIONS, COUPLER,CONNECTORS, END CAPS, HANGERS, POWER FEED UNITS, ETC.� FOR A PROFESSIONALINSTALLATION. SUPPORT BUSWAY FROM THE CEILING BY STANDARD HANGERS ASRE�UIRED BY THE MANUFACTURER. COORDINATE BUSWAY LOCATION AND MOUNTINGHEIGHT WITH THE LOW VOLTAGE CONTRACTOR PRIOR TO ROUGH-IN. COORDINATE THETYPE AND NUMBER OF PLUG-IN UNITS WITH THE OWNER PRIOR TO ORDERING.
1 1/2"C - 3 #4, 1 #1N, 1 #8 GND, 1 #8 I GND.
1
SHEET NOTES�
2
3
06/01/18 ADDENDUM #111
4
5
6
7
8
07/13/18 ADDENDUM #152
CONFERENCE28
44 SHIFT47
48
OPERATIONMANAGER
30STO29
GENERALMANAGER
31MOD
32EVS STORAGE
33FIRE RISER
34EMERGENCYELECTRICAL
35
ELECTRICAL36 REVENUE AUDIT
46
AUDIT45 SURVEILLANC
MANAGER
55
CORRIDOR26
CORRIDOR26
FJP25
2723
23
36
3625 32 37
C
F
K
J
L2E
L2
L2
L2E
L2E
L2
�1
L2
L28� 8� 8�8�
8�
8�
8�
8�
L12
7 7
M
L2
M
L2 L2
L2
L6
7�
L3E
2
L3
1
L3E
2
L3
1
L2E L2
L2 L2E
L2E L2
L14
L14
L14
L14
L14
L14
L14
L14 L14
L14 L14�1
8�7�
8�7� 7�
8�
8
7
77
77
7
7�
7�
7�8�
8�
8�
3�
3a
3c
3�
7c 7c
7c
7c
7c
7c
7c7c
7c
7c
7c
2
L12
L12E
L12E
L12E
L12E
L12E L12E L12E L12E
MATCH
LIN
E
SEE S
HEET E
6.3
MATCH
LIN
E
SEE S
HEET E
6.4
MATCHLINE
SEE SHEET E6.1
PANEL 'TCEH'
J
TCEH-2�SPLIT CKT�
J
TCEH-8�SPLIT CKT�
11
J
TCHLT1-1�SPLIT CKT�
J
TCHLT1-7�SPLIT CKT�
1
1
MATCHLINE
SEE SHEET E6.2S3�
S3�
S�
S�
S�
3�
3c
L11E 18L11E18
L11E18
J
TCEH-18�SPLIT CKT�
1#10
1
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E6.1A
ENLARGED LIGHTINGPLAN - EAST
A
NORTH
E6.1A
ENLARGED LIGHTING PLAN - EAST1/8" = 1'-0"
2' 16'8'4'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS. ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT,UNLESS NOTED OTHERWISE.
1. REFER TO SHEET E6.2 FOR LOCATION OF PANEL 'TCHLT1'.
2. PROVIDE CONSTANT HOT TO ALL LIGHT FI�TURES WITH INTEGRAL EMERGENCYBATTERY.
1
SHEET NOTES�
GENERAL NOTES�
1 07/13/18 ADDENDUM #15
VESTIBULE103C
ULT
UR
E10
3A
CU
LTU
RE
103B
8 10
9
9
9
9
1111
11
11 1111
11
11
9 9
9
J
TCHLT2-9,11 1
LDJ�TYPICAL�
#10
J 39S5
J 39S4
JTCHLT2-391
J 39S5
J 39S4
J 39S5
J 39S4
J39S5
J39S4
J39S5
J39S4
J39S5
J39S4
2
22
2 2
Mens90
EVS90A
3 5
46
15
15
15
15
15
15
13
13
13 13
13
13 13
13
13
LDJ�TYPICAL�
LDJ�TYPICAL�
J
TCHLT2-13,15 12
2
2 2 2
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E7.1
ENLARGEDEXTERIOR LIGHTING
PLAN
B
A
NORTH
E7.1
ENLARGED E�TERIOR LIGHTING PLAN1/4" = 1'-0"
1' 8'4'2'0'
B
NORTH
E7.1
ENLARGED E�TERIOR LIGHTING PLAN1/4" = 1'-0"
1' 8'4'2'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS. ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT,UNLESS NOTED OTHERWISE.
1. REFER TO SHEET E1.0 FOR LOCATION OF PANEL 'TCHLT2'.
1
SHEET NOTES�
GENERAL NOTES�
05/22/18 ADDENDUM #101
07/13/18 ADDENDUM #152
Womens92
EVS92A
CU
LTU
RE
103B
10 15
17 20 22
13
DD
7
7
7 7
7
7 7
7
7 5
5
5 5
5
5 5
5
5
LDJ�TYPICAL�
LDJ�TYPICAL�
33
3
3 33
3
3
J
TCHLT2-3,5,7 1#10
2 2 2 2 2 2
22
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E7.2
ENLARGEDEXTERIOR LIGHTING
PLAN
A
NORTH
E7.2
ENLARGED E�TERIOR LIGHTING PLAN1/4" = 1'-0"
1' 8'4'2'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS. ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT,UNLESS NOTED OTHERWISE.
1. REFER TO SHEET E1.0 FOR LOCATION OF PANEL 'TCHLT2'.
1
SHEET NOTES�
GENERAL NOTES�
07/13/18 ADDENDUM #151
07/13/18 ADDENDUM #152
VESTIBULE00
LOBBY01
STORAGE08MARKETING
06IDF05
VESTIBULE03
PLAYERSCLUB
07
MENS11
CU
LTU
RE
00A
CU
LTU
RE
00B
24 26 28 34 3529 33
HH
JJ
1
1
1 1
1
1 1
1
1 12
12
12 12
12
12
2424
24
24
2222
22
22
2424
24
2414
14
14
14
1414
14
14
1616
16
16
J
TCHLT2-1 1
J
TCHLT1-20,22,24�SPLIT CRKT�
1
J
TCHLT1-14,16,18�SPLIT CRKT�
1
J
TCHLT1-12�SPLIT CKT�
1
LDJ�TYPICAL�
LDJ�TYPICAL�
#10
#10 #10
#10
J 26S5
J 26S4
J 26S5
J 26S4
J 26S5
J 26S4
J28S5
J28S4
J28S5
J28S4
J28S5
J28S4
J28S5
J28S4
J28S5
J28S4
J28S5
J28S4
J28S5
J28S4
J28S5
J28S4
J
TCHLT1-28�SPLIT CKT�
1
J
TCHLT1-26�SPLIT CKT�
1
J 26S5
J 26S4
J 26S5
J 26S4
J 26S5
J 26S4
J 26S5
J 26S4
J 26S5
J 26S4
222
2
2
2
2
2
2
2 2
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E7.3
ENLARGEDEXTERIOR LIGHTING
PLAN
A
NORTH
E7.3
ENLARGED E�TERIOR LIGHTING PLAN1/4" = 1'-0"
1' 8'4'2'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS. ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT,UNLESS NOTED OTHERWISE.
1. REFER TO SHEET E1.0 FOR LOCATION OF PANELS 'TCHLT1', 'TCHLT2', AND 'TCHLT3'.
1
SHEET NOTES�
GENERAL NOTES�
05/22/18 ADDENDUM #101
07/13/18 ADDENDUM #152
26 28 30 31 34 3529 33
LL
MM
NN20
20
20
20
2020
20
20
2222
22
22 1616
16
16
1818
18
18
1818
18
18
J J
TCHLT1-20,22�SPLIT CRKT�
1 TCHLT1-16,18�SPLIT CRKT�
1
#10 #10
LDJ�TYPICAL�
J 26S5
J 26S4
J28S5
J28S4 J28
S5
J28S4
J 26S5
J 26S4
J 26S5
J 26S4
J28S5
J28S4
J
TCHLT1-28�SPLIT CKT�J
TCHLT1-26�SPLIT CKT�
1
2
2
2
2
2
2
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E7.4
ENLARGEDEXTERIOR LIGHTING
PLAN
A
NORTH
E7.4
ENLARGED E�TERIOR LIGHTING PLAN1/4" = 1'-0"
1' 8'4'2'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS. ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT,UNLESS NOTED OTHERWISE.
1. REFER TO SHEET E1.0 FOR LOCATION OF PANELS 'TCHLT1' AND 'TCHLT3'.
1
SHEET NOTES�
GENERAL NOTES�
05/22/18 ADDENDUM #101
07/13/18 ADDENDUM #152
ST WOMENS VEST14
EVS STORAGE12
MENS11
WOMENS13 VIP EVENT
76T
CU
LTU
RE
102A
41
38
12
12
12 10
10
10 10
10
10 10
10
10J
TCHLT1-12�SPLIT CKT�
1
J
TCHLT1-101
LDJ�TYPICAL�
LDJ�TYPICAL�
#10 #10
1 1 1 1
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E7.5
ENLARGEDEXTERIOR LIGHTING
PLAN
A
NORTH
E7.5
ENLARGED E�TERIOR LIGHTING PLAN1/4" = 1'-0"
1' 8'4'2'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS. ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT,UNLESS NOTED OTHERWISE.
1. REFER TO SHEET E1.0 FOR LOCATION OF PANEL 'TCHLT1'.
1
SHEET NOTES�
GENERAL NOTES�
07/13/18 ADDENDUM #151
WAITING86
CONNECTIONVESTIBULE
102
CU
LTU
RE
102A
CU
LTU
RE
102B
41
41
43
43
8
8
8 6
6
6
88
8
8 66
6
6
8
8
6
6
J
TCHLT1-6,81
LDJ�TYPICAL�
LDJ�TYPICAL�
#10
J 30S5
J 30S4
JTCHLT2-301 J30
S5
J30S4
J 30S5
J 30S4
J30S5
J30S4
J 30S5
J 30S4
J30S5
J30S4
2
2 2
2
2 2
DINING84
Bar85
PRIVATEDINING
45
4
4
4 4
4
4
4
4 4
2
2 2
2
22
2
22
J
TCHLT1-2,41
LDJ�TYPICAL�
LDJ�TYPICAL�
#10
2 2
2
2
2
2
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E7.6
ENLARGEDEXTERIOR LIGHTING
PLAN
A
NORTH
E7.6
ENLARGED E�TERIOR LIGHTING PLAN1/4" = 1'-0"
1' 8'4'2'0'
B
NORTH
E7.6
ENLARGED E�TERIOR LIGHTING PLAN1/4" = 1'-0"
1' 8'4'2'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS. ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT,UNLESS NOTED OTHERWISE.
1. REFER TO SHEET E1.0 FOR LOCATION OF PANEL 'TCHLT1' AND 'TCHLT3'.
1
SHEET NOTES�
GENERAL NOTES�
05/22/18 ADDENDUM #101
07/13/18 ADDENDUM #152
LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED
LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
1 1 1 1 1 2 2
J
2 2 2 2 2 3 33 3 3 4 44 5 543
TCDRN-1,21
J
TCDRN-3,41
J
TCDRN-5,61
13 13 13 13 13 14 1414 14
1
13 14 14 14 15 1515 15 15 16 1616 17 171615
J
TCDRN-13,14 1J
TCDRN-15,161
J
TCDRN-17,181
1 1
LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED
LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
LF-02
LF-01
5 5 5 5 5 6 66 6 7 77 87 8 8 8 8 8
J
TCDRN-7,81
17 17 17 17 17 18 18 18 19 19 19 2019 20 20 20 20 2018
J
TCDRN-19,201
1 1
LED LED LED LED LED LED LED LED LED
LED LED LED LED LED LED LED LED LED
LF-01
LF-01 LF-01
LF-01 LF-01
LF-01
LF-01
LF-01
9 9 9 9 10 10 10 10
J
TCDRN-9,101
29 29 29 30 30 30 3029
J
TCDRN-29,301
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E7.7
ELECTRICALELEVATION WEST
A
E7.7
ELECTRICAL ELEVATION WEST1/8" = 1'-0"
2' 16'8'4'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS. ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT,UNLESS NOTED OTHERWISE.
1. VERIFY E�ACT LOCATION OF ALL LIGHT FI�TURES WITH ARCHITECT PRIOR TOROUGH-IN.
2. REFER TO SHEET ��.�� FOR LOCATION OF DIMMER PANEL 'TCDRN'.
1
SHEET NOTES�
GENERAL NOTES�
07/13/18 ADDENDUM #151
LED LED LED
LED LED LED
LF-02
LF-01
1 1
J
TCDRN-1�SPLIT CKT�
1
13 13
J
TCDRN-13�SPLIT CKT�
1
1
LED LED LED LED LED LED LED LED
LED LED LED LED LED LED LED LED LED
LF-01
LF-01
11 1111111111
J
TCDRN-11 1
J
1TCDRN-31
31 3131 3131 31
LF-01
LF-01
LF-01
LF-01
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
BID PACKAGE 05
05/03/18
E7.8
ELECTRICALELEVATIONS NORTH
AND SOUTH
A
E7.8
ELECTRICAL ELEVATION SOUTH1/8" = 1'-0"
2' 16'8'4'0'
A
E7.8
ELECTRICAL ELEVATION NORTH1/8" = 1'-0"
2' 16'8'4'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS. ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT,UNLESS NOTED OTHERWISE.
1. VERIFY E�ACT LOCATION OF ALL LIGHT FI�TURES WITH ARCHITECT PRIOR TOROUGH-IN.
2. REFER TO SHEET ��.�� FOR LOCATION OF DIMMER PANEL 'TCDRN'.
1
SHEET NOTES�
GENERAL NOTES�
07/13/18 ADDENDUM #151
S S
S2S2
S2
S2
S2
S2 S2
S2
S2
S2 S2
S2
S2
S2
S2
S2
S2
S2 S2 S2
S2
S1
S1
S1
S1
S3S3
S3S3
S3 S3S3
S3
S2
S2
S2
S2
S1
S1
S2
S2
S2
S2S2
S2
S2 S2
S2
S2
S2
2"EC TO MAIN SERVICE SWITCHBOARD 'TCMSB'
2"EC TO MAIN SERVICE SWITCHBOARD'TCMSA'
2"EC TO MAIN SERVICE SWITCHBOARD 'TCMSA'
2"EC TO MAIN SERVICE SWITCHBOARD 'TCMSA'2"EC TO MAIN SERVICE SWITCHBOARD 'TCMSA'
1"EC
1"EC
1"EC
1"EC
1 1/4"EC
1"EC
1 1/4"EC
1 1/4"EC
1"EC1"EC1"EC
1"EC
1 1/4"EC
1"EC
1"EC
1 1/4"EC
1"EC
1 1/4"EC
1 1/4"EC 1 1/4"EC 1 1/4"EC
1"EC1"EC1"EC 1"EC 1"EC 1"EC1"EC
1"EC1 1/4"EC 1 1/4"EC 1 1/4"EC
1 1/4"EC
1"EC
1 1/4"EC
1"EC
1"EC
1"EC
1"EC
1"EC
1"EC
1"EC
1 1/4"EC
1 1/4"EC
1 1/4"EC
1"EC
1"EC
1"EC
1"EC1"EC
1 1/4"EC
1 1/4"EC
1"EC 1"EC
1"EC1"EC
1 1/4"EC
1 1/4"EC
1"EC
1"EC
1"EC
1 1/4"EC1"EC
1 1/4"EC
1 1/4"EC
1 1/4"EC
1"EC
1"EC
1"EC
1"EC
1"EC
1"EC
1"EC
1"EC
1"EC1"EC
1 1/4"EC
1"EC 1"EC
1 1/4"EC
�13,15��13,15�
�13,15� �13,15�
�9,11�
�5,7�
5
5
2
2
4
2
22
2�9,11�
�5,7� �5,7�
�5,7�
�5,7�
�1,3�
�1,3��1,3��1,3�
222
22
2
222222222
2
2
2
33
2
2
3
22
5
2
2
2
2
2
2
2
2
2
3
22
2
2
2
22
2
2
�9,11�
�9,11�
�9,11�
�1,3�
�1,3�
22
5
2
2
�2,4��2,4��2,4�
�2,4�
�2,4� �10,12�
�10,12�
�10,12�
�10,12�
�10,12�
�6,8�
�6,8��6,8�
�6,8��6,8�
�14,16�
�14,16� �14,16�
�14,16� �18,20�
2
2
6
2
WP WP
8 8
�18,20��18,20�
�18,20�
2
2
2
�17,19�
2
7
2
�13,15�
3
2
�17,19�
�17,19�
32
�17,19�
3
2
2
2
2
2
2
2
�17,19�
�21,23� �21,23�
�21,23�
�21,23�
�2,4� �1,3�
WP
TCIDF1-4#10
TCIDF1-6
#10
WP
TCIDF1-8#10
WP TCIDF1-10#10
WP�ON ROOF�
TCIDF1-2 #10
10TYP. 2
WP
TCIDF1-12
#10
WP
TCIDF1-14 #10
WP
TCIDF3-2#10
WP
TCIDF3-10 #10
WP
TCIDF3-8 #10
WP
TCIDF3-12#10
WP
TCIDF3-6#10WP
TCIDF3-4#10
WP
TCIDF2-10#10
WP
TCIDF2-8#10
WP
TCIDF2-4#10 9TYP. 17
WP
TCIDF2-6 #10
WP
TCIDF2-2
#10
WPTCIDF1-16#10
3
S3
3
S3
3
S3
3
S3
3
WP
3
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
BID PACKAGE 02(100% SET)
03/27/18 17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
ES1.0
ELECTRICAL SITEPLAN
A
NORTH
ES1.0
ELECTRICAL SITE PLAN1" = 50'-0"
100'50'25'0'
E�TEND AND CONNECT CIRCUITING FROM JUNCTION BO� TO OUTLETS IN AREA WITHSAME CIRCUIT NUMBERS, ROUTE #12 CONDUCTORS �MINIMUM� THROUGHOUT, UNLESSNOTED OTHERWISE.
2#8, 1#8 GND IN E�ISTING CONDUIT.
4#8, 1#8 GND IN E�ISTING CONDUIT.
6#8, 1#8 GND IN E�ISTING CONDUIT.
8#8, 1#8 GND IN E�ISTING CONDUIT.
10#8, 1#8 GND IN E�ISTING CONDUIT.
12#8, 1#8 GND IN E�ISTING CONDUIT.
FURNISH AND INSTALL 750 VA, 480V, 1ɸ TO 120V, 1ɸ ENCAPSULATED TRANSFORMERWITH LINE AND LOAD IN-LINE FUSES IN WEATHERPROOF BO�.
FURNISH AND INSTALL WEATHERPROOF GFCI RECEPTACLE FOR OUTDOOR SPEAKER ATINDICATED LIGHT POLES. COORDINATE RECEPTACLE MOUNTING HEIGHT ANDINSTALLATION RE�UIREMENTS WITH THE AV CONTRACTOR PRIOR TO ROUGH-IN.
FURNISH AND INSTALL WEATHERPROOF GFCI RECEPTACLE ON THE ROOF NEAR THEEDGE OF THE BUILDING FOR AUDIO SYSTEM TRANSMITTER. COORDINATE RECEPTACLEMOUNTING LOCATION AND INSTALLATION RE�UIREMENTS WITH THE AV CONTRACTORPRIOR TO ROUGH-IN.
1
SHEET NOTES�
2
3
4
5
6
7
8
05/03/18 BID PACKAGE 051
06/01/18 ADDENDUM #112
9
10
07/13/18 ADDENDUM #153
IMF
4"EC
1"EC4"EC
1"EC
1"EC
4"EC
1"EC
1"EC
1"EC
4"EC
4"EC
1"EC1"EC
4"EC
4"EC
1"EC1"EC
1"EC
1"EC
1"EC
1"EC
4"EC
1"EC
1"EC
1"EC
4"EC
4"EC
4"EC
1"EC
1"EC
1"EC
1"EC1"EC
4"EC1"EC
1"EC
4"EC
4"EC TO MDF
4"EC
1"EC
4"EC
4"EC
PROFESSIONAL SEAL:
45 South 4th StreetFort Smith, AR 72901
479-783-2480www.childersarchitect.com
James R. ChildersArchitect, Inc.
PROJECT PHASE:
REVISIONS
DATE: JOB NUMBER:
SHEET NUMBER:
04
8
1/8"
=1'
-0"
04
1/4"
=1'
-0"
04
3/8"
=1'
-0"
04
1/2"
=1'
-0"
6"2
3/4"
=1'
-0"
06"
1
1" =
1'-0
"
06"
1
1 1/
2" =
1'-0
"
01
3" =
1'-0
"
6"16
8
CLIENT:
CONSULTANT LOGO:
BID PACKAGE 02(100% SET)
03/27/18 17-06
TAH
LEQ
UA
H C
AS
INO
CH
ER
OK
EE
NA
TIO
N E
NTE
RTA
INM
EN
T
TAH
LEQ
UA
H, O
KLA
HO
MA
# DATE DESCRIPTION
msa-ec.com
Las Vegas, NV 89123370 E Windmill Lane, Suite 100
702.896.1100
MSA#L18041
JULY 13, 2018
ES1.0A
ELECTRICAL SITEPLAN - CCTV
INFRASTRUCTURE
A
NORTH
ES1.0A
ELECTRICAL SITE PLAN - CCTV INFRASTRUCTURE1" = 50'-0"
100'50'25'0'
05/03/18 BID PACKAGE 051
07/13/18 ADDENDUM #152
ENTIRE SHEETREVISED
2