155.3202. SINGLE-FAMILY RESIDENCE 1 (RS-1) · Article 3: Zoning Districts Part 2 Residential Base...
Transcript of 155.3202. SINGLE-FAMILY RESIDENCE 1 (RS-1) · Article 3: Zoning Districts Part 2 Residential Base...
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3202 Single-Family Residence 1 (RS-1)
Adopted September 2012, Amended Jan., Feb., and July 2013 City of Pompano Beach, Florida
Page 3-4 Zoning Code
155.3202. SINGLE-FAMILY RESIDENCE 1 (RS-1)
A. PURPOSE TYPICAL BUILDING TYPE The Single-Family Residence 1 (RS-1) District is established and intended to accommodate primarily
single-family dwellings at low densities on lots greater than 12,000 square feet in area. The district also
accommodates accessory dwelling units as well as limited nonresidential uses usually found in urban
single-family neighborhoods, generally as Special Exceptions.
B. USE STANDARDS See Appendix A: Consolidated Use Table, and use-specific standards in Article 4: Use Standards.
C. INTENSITY AND DIMENSIONAL STANDARDS 1
Lot area, minimum (sq ft) 12,000 TYPICAL LOT PATTERN Lot width, minimum (ft) 90
2
Density, maximum (du/ac) See Comprehensive Plan 3
Floor area per dwelling unit, minimum (sq ft) 1,500 for up to 3 bedrooms, plus 100
per additional bedroom
Lot coverage, maximum (% of lot area) 30
Pervious area, minimum (% of lot area) 30
Height, maximum (ft) 35
Front yard setback, minimum (ft) 35
Street side yard setback, minimum (ft)
18
Setback from a waterway or canal, minimum (ft)
25
Interior side yard setback, minimum (ft)
10
Rear yard setback, minimum (ft)
20
Required Front Yard, Pervious Area, minimum (% of Required
Front Yard) 50
Dimensional Standards for Accessory Structures See Accessory Use-Specific standards in Article 4: Part 3. NOTES: [sq ft = square feet; ft = feet; du/ac = dwelling units/acre]
1. See measurement rules and allowed exceptions/variations in Article 9: Part 4 .
2. 110 ft for a corner lot.
3. On land classified Residential by the Land Use Plan, maximum gross residential density may not exceed that established for the particular land use
classification.
TYPICAL DEVELOPMENT CONFIGURATION
SINGLE-FAMILY DWELLING Min lot area = 12,000 sq ft
Min floor area = 1,500 sq ft
Max lot coverage = 30%
S
Min street side yard setback: 18’
Min corner lot width: 110’
Min lot width: 90’
Max height: 35’ Min interior side
yard setback; 10’
Min rear
yard
setback: 20’
Min front yard
setback: 35’
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3203 Single-Family Residence 2 (RS-2)
City of Pompano Beach, Florida Adopted Sept. 2012; Amended Jan. 2013, Feb. 2013, & July 2013
Zoning Code Page 3-5
155.3203. SINGLE-FAMILY RESIDENCE 2 (RS-2)
A. PURPOSE TYPICAL BUILDING TYPE The Single-Family Residence 2 (RS-2) district is established and intended to accommodate primarily single-
family dwellings at moderate densities on lots greater than 7,000 square feet in area. The district also
accommodates accessory dwelling units as well as limited nonresidential uses usually found in urban single-
family neighborhoods (e.g., parks, places of worship, golf courses), generally as Special Exceptions.
B. USE STANDARDS See Appendix A: Consolidated Use Table, and use-specific standards in Article 4: Use Standards.
C. INTENSITY AND DIMENSIONAL STANDARDS 1
Lot area, minimum (sq ft) 7,000 TYPICAL LOT PATTERN
Lot width, minimum (ft) 70
Density, maximum (du/ac) See Comprehensive Plan 2
Floor area per dwelling unit, minimum (sq ft) 1,250
Lot coverage, maximum (% of lot area) 40
Pervious area, minimum (% of lot area) 30
Height, maximum (ft) 355
Front yard setback, minimum (ft) 25
Street side yard setback, minimum (ft)
15
Setback from a waterway or canal, minimum (ft)
25 3
Interior side yard setback, minimum (ft)
7.5
Rear yard setback, minimum (ft) 20 5
Required Front Yard, Pervious Area, minimum (% of Required
Front Yard) 50
Dimensional Standards for Accessory Structures See Accessory Use-Specific standards in Article 4: Part 3.
NOTES: [sq ft = square feet; ft = feet; du/ac = dwelling units/acre]
1. See measurement rules and allowed exceptions/variations in Article
9:Part 4 .
2. On land classified Residential by the Land Use Plan, maximum gross
residential density may not exceed that established for the particular land
use classification.
3. On existing lot where rear yard abuts waterway or canal, setback equals
the existing rear yard depth if it is between 15 ft and 25 ft.
4. On existing lot, setback equals the existing rear yard depth if it is
between 15 ft and 20 ft.
5. The maximum height may be increased to 40 feet where the lowest
structural member of a building must be 14.5 feet or more above National
Geodetic Vertical Datum of 1929 (N.G.V.D)
TYPICAL DEVELOPMENT CONFIGURATION
SINGLE-FAMILY DWELLING Min lot area = 7,000 sq ft
Min floor area = 1,250 sq ft
Max lot coverage = 40%
Min front yard
setback: 25’
Min rear
yard
setback: 20’
Min interior side
yard setback:
7.5’
Min setback
from
waterway or
canal: 25’
Min street side yard
setback: 15’
Min lot width: 70’
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3204 Single-Family Residence 3 (RS-3)
Adopted September 2012, Amended Jan., Feb., and July 2013 City of Pompano Beach, Florida
Page 3-6 Zoning Code
155.3204. SINGLE-FAMILY RESIDENCE 3 (RS-3)
A. PURPOSE TYPICAL BUILDING TYPE The Single-Family Residence 3 (RS-3) district is established and intended to accommodate primarily
single-family dwellings at moderate densities on lots greater than 6,000 square feet in area. The district
also accommodates accessory dwelling units as well as limited nonresidential uses usually found in
urban single-family neighborhoods,, generally as Special Exceptions.
B. USE STANDARDS See Appendix A: Consolidated Use Table, and use-specific standards in Article 4: Use Standards.
C. INTENSITY AND DIMENSIONAL STANDARDS 1
Lot area, minimum (sq ft) 6,000 TYPICAL LOT PATTERN Lot width, minimum (ft) 60
Density, maximum (du/ac) See Comprehensive Plan2
Floor area per dwelling unit, minimum (sq ft) 750
Lot coverage, maximum (% of lot area) 40
Pervious area, minimum (% of lot area) 30
Height, maximum (ft) 35
Front yard setback, minimum (ft) 25
Street side yard setback, minimum (ft) 15
Setback from a waterway or canal, minimum (ft) 25
Interior side yard setback, minimum (ft) 7
Rear yard setback, minimum (ft) 15
Required Front Yard, Pervious Area, minimum (% of Required
Front Yard) 50
Dimensional Standards for Accessory Structures See Accessory Use-Specific standards in Article 4: Part 3.
NOTES: [sq ft = square feet; ft = feet; du/ac = dwelling units/acre]
1. See measurement rules and allowed exceptions/variations in Article 9:Part 4 .
2. On land classified Residential by the Land Use Plan, maximum gross residential density may not exceed that established for the particular
land use classification.
TYPICAL DEVELOPMENT CONFIGURATION
SINGLE-FAMILY DWELLING Min lot area = 6,000 sq ft
Min floor area = 750 sq ft
Max lot coverage = 40%
Min front yard
setback: 25’
Min rear
yard
setback: 15’
Max height: 35’
Min interior
side yard
setback: 7’
Min setback
from
waterway
or canal: 25’
Min street side
yard setback: 15’
Min lot width: 60’
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3205 Single-Family Residence 4 (RS-4)
City of Pompano Beach, Florida Adopted Sept. 2012; Amended Jan. 2013, Feb. 2013, & July 2013
Zoning Code Page 3-7
155.3205. SINGLE-FAMILY RESIDENCE 4 (RS-4)
A. PURPOSE TYPICAL BUILDING TYPE The Single-Family Residence 4 (RS-4) district is established and intended to accommodate primarily
single-family dwellings at moderate densities on lots greater than 5,000 square feet in area. The district
also accommodates accessory dwelling units and zero-lot-line development, as well as limited
nonresidential uses usually found in urban single-family neighborhoods, generally as Special
Exceptions.
B. USE STANDARDS
See Appendix A: Consolidated Use Table, and use-specific standards in Article 4: Use Standards.
C. INTENSITY AND DIMENSIONAL STANDARDS 1
Lot area, minimum (sq ft) 5,000 TYPICAL LOT PATTERN
Lot width, minimum (ft) 50
Density, maximum (du/ac) See Comprehensive Plan 2
Floor area per dwelling unit, minimum (sq ft) 675
Lot coverage, maximum (% of lot area) 40
Pervious area, minimum (% of lot area) 30
Height, maximum (ft) 35
Front yard setback, minimum (ft) 25
Street side yard setback, minimum (ft) 15
Setback from a waterway or canal, minimum (ft) 25
Interior side yard setback, minimum (ft) 63
Rear yard setback, minimum (ft) 15
Required Front Yard, Pervious Area, minimum (% of Required Front
Yard) 50
Dimensional Standards for Accessory Structures See Accessory Use-Specific standards in Article 4: Part 3.
NOTES: [sq ft = square feet; ft = feet; du/ac = dwelling units/acre]
1. See measurement rules and allowed exceptions/variations in Article 9:Part 4
2. On land classified Residential by the Land Use Plan, maximum gross residential density may not exceed that established for the particular
land use classification.
3. For developments with zero-lot-line single family dwellings, 0 ft along the zero lot line and 15 ft for the opposite interior side lot line.
TYPICAL DEVELOPMENT CONFIGURATION
A SINGLE-FAMILY DWELLING B. SINGLE-FAMILY DWELLING, ZERO-LOT LINE Min lot area = 5,000 sq ft
Min floor area = 525 sq ft
Max lot coverage = 40%
Min front
yard
setback: 25’
Min rear yard
setback: 15’
Min interior
side yard
setback: 6’
Min street side
yard setback: 15’
Min lot width: 50’
Min interior side
yard setback
opposite zero-lot-
line: 15’
Max height: 35’
A
B
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3206 Single-Family Residence Lesureville (RS-L)
Adopted September 2012, Amended Jan., Feb., and July 2013 City of Pompano Beach, Florida
Page 3-8 Zoning Code
155.3206. SINGLE-FAMILY RESIDENCE LESUREVILLE (RS-L)
A. PURPOSE TYPICAL BUILDING TYPE The Single-Family Residence Leisureville (RS-L) district is established and intended to accommodate
primarily cluster developments containing single-family dwellings at a density of one dwelling per 5,000
square feet of site area, and where the site area is held in common by all owners of dwellings in the
development. The district also accommodates accessory dwelling units and development-serving
recreation facilities and community centers, as well places as of worship (as a Special Exception).
B. USE STANDARDS See Appendix A: Consolidated Use Table, and use-specific standards in Article 4: Use Standards.
B. INTENSITY AND DIMENSIONAL STANDARDS 1
Gross site area per dwelling, minimum (sq ft) 5,000 TYPICAL LOT PATTERN Lot width. minimum (ft) n/a
Density, maximum (du/ac) See Comprehensive Plan 2
Floor area per dwelling unit, minimum (sq ft) 600
Lot coverage, maximum (% of lot area) 35
Pervious area, minimum (% of lot area) 30
Height, maximum (ft) 35
Setback from street, minimum (ft) 15 3
Setback from another zoning district, minimum (ft) 15
Setback from a waterway or canal, minimum (ft) 25
Spacing between principal structures, minimum (ft) 10 4
Required Front Yard, Pervious Area, minimum (% of Required Front
Yard) 50
Dimensional Standards for Accessory Structures See Accessory Use-Specific standards in Article 4: Part 3.
NOTES: [sq ft = square feet; ft = feet; du/ac = dwelling units/acre]
1. See measurement rules and allowed exceptions/variations in Article 9:Part 4 .
2. On land classified Residential by the Land Use Plan, maximum gross residential density may not exceed that established for the particular
land use classification.
3. 25 ft from a major arterial street and for the garage door side of a dwelling (from any street).
4. Increased to 15 ft between a one-story structure and a two-story structure and 20 ft between structures with 2 or more stories each.
TYPICAL DEVELOPMENT CONFIGURATION
SINGLE-FAMILY DWELLING Min lot area = 5,000 sq ft
Min floor area = 600 sq ft
Max lot coverage = 35%
Min front yard
setback with
front garage
door or from
major arterial
street: 25’
Min spacing
between one-
story and two-
story
structures: 15’
Min spacing
between two
one-story
structures: 10’
Min spacing between
two two-story
structures: 20’
Max height: 35’ Min front yard
setback without
front garage
door: 15’
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3207 Two-Family Residence (RD-1)
City of Pompano Beach, Florida Adopted Sept. 2012; Amended Jan. 2013, Feb. 2013, & July 2013
Zoning Code Page 3-9
155.3207. TWO-FAMILY RESIDENCE (RD-1)
A. PURPOSE TYPICAL BUILDING TYPE The Two-Family Residence (RD-1) district is established and intended to accommodate primarily single-
family dwellings and two-family dwellings at moderate densities. The district also accommodates
accessory dwelling units (with single-family dwellings) as well as limited nonresidential uses usually
found in urban single-family neighborhoods (e.g., parks, places of worship, golf courses), generally as
Special Exceptions.
B. USE STANDARDS See Appendix A: Consolidated Use Table, and use-specific standards in Article 4: Use Standards.
C. INTENSITY AND DIMENSIONAL STANDARDS 1
Lot area, minimum (sq ft) SF: 7,000 2F: 8,000 TYPICAL LOT PATTERN Lot width, minimum (ft) SF: 60 2F: 70
Density, maximum (du/ac) 12 2
Floor area per dwelling unit, minimum (sq ft) 750
Lot coverage, maximum (% of lot area) 35
Pervious area, minimum (% of lot area) 30
Height, maximum (ft) 35
Front yard setback, minimum (ft) 25
Street side yard setback, minimum (ft) 18
Setback for a waterway or canal, minimum (ft) 25
Interior side yard setback, minimum (ft) 8
Rear yard setback, minimum (ft) 15
Required Front Yard, Pervious Area, minimum (% of Required
Front Yard) 50
Dimensional Standards for Accessory Structures See Accessory Use-Specific standards in Article 4: Part 3.
NOTES: [sq ft = square feet; ft = feet; du/ac = dwelling units/acre; SF = single-family dwelling; 2F = two-family dwelling]
1. See measurement rules and allowed exceptions/variations in Article 9:Part 4 .
2. On land classified Residential by the Land Use Plan, maximum gross residential density may not exceed that established for the particular
land use classification.
TYPICAL DEVELOPMENT CONFIGURATION
TWO-FAMILY DETACHED DWELLING Min lot area SF = 7,000 sq ft
Min lot area 2F = 8,000 sq ft
Min floor area = 525 sq ft
Max lot coverage = 35%
Min front yard
setback: 25’ Min
interior
side yard
setback:
8’
Min setback from
waterway
or canal: 25’
Min lot
width 2F: 70’
Min lot
width SF: 60’
Min street side yard setback: 18’
Min rear
yard
setback: 25’
Min setback from waterway or canal: 25’
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3208 Multiple-Family Residence 7 (RM-7)
Adopted September 2012, Amended Jan., Feb., and July 2013 City of Pompano Beach, Florida
Page 3-10 Zoning Code
155.3208. MULTIPLE-FAMILY RESIDENCE 7 (RM-7)
A. PURPOSE TYPICAL BUILDING TYPE The Multiple-Family Residence 7 (RM-7) district is established and intended to accommodate primarily
multifamily dwellings (including townhouse development) at low to moderate densities. The district also
accommodates single-family and two-family dwellings, zero-lot-line development, community residential
homes, assisted living facilities, and continuing care retirement communities. Limited nonresidential uses are
allowed as Special Exceptions.
B. USE STANDARDS See Appendix A: Consolidated Use Table, and use-specific standards in Article 4: Use Standards.
C. INTENSITY AND DIMENSIONAL STANDARDS 1
Lot area, minimum (sq ft) 7,000 2
Lot width, minimum (ft) 60 2
TYPICAL LOT PATTERN Density, maximum (du/ac) 7
2,3
Floor area per dwelling unit, minimum (sq ft)
SF 950
2F 750
MF Efficiency units: 500
Other units: 650 + 100 per BR>1
Lot coverage, maximum (% of lot area) 60 2
Pervious area, minimum (% of lot area) 25 2
Height, maximum (ft) 35
Front yard setback, minimum (ft) 25
Street side yard setback, minimum (ft) 8 2,4
Setback from a waterway or canal, minimum (ft)
25
Setback from a dune vegetation line, minimum (ft) 25
Interior side yard setback, minimum (ft)
8 2,5
Rear yard setback, minimum (ft)
10
Spacing between principal structures, minimum (ft) 25
Required Front Yard, Pervious Area, minimum (% of
Required Front Yard) 50 (for Single Family Dwellings only)
Dimensional Standards for Accessory Structures See Accessory Use-Specific standards in Article 4: Part 3.
NOTES: [sq ft = square feet; ft = feet; du/ac = dwelling units/acre; SF = single-family dwelling; 2F = two-family dwelling; MF = multifamily dwelling;
BR = bedroom]
1. See measurement rules and allowed exceptions/variations in Article 9:Part 4 .
2. For townhouse development, applies only to the development site as a whole, provided individual townhouse lots have a minimum area of 1,800 sq ft
and a minimum width of 18 ft.
3. On land classified Residential by the Land Use Plan, maximum gross residential density may not exceed that established for the particular land use
classification.
4. Those portions of a structure extending above a height of 20 feet shall be set back an additional 1 ft for each 4 ft (or major fraction thereof) the height
of the portion of the structure exceeds 20 ft.
5. For developments with zero-lot-line single family dwellings, 0 ft along the zero lot line and 15 ft for the opposite interior side lot line.
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3208 Multiple-Family Residence 7 (RM-7)
City of Pompano Beach, Florida Adopted Sept. 2012; Amended Jan. 2013, Feb. 2013, & July 2013
Zoning Code Page 3-11
TYPICAL DEVELOPMENT CONFIGURATION
MULTIFAMILY DWELLING Min lot area = 7,000 sq ft
Max lot coverage = 60% Min street side yard setback: 8’
Min front yard
setback: 25’
Min lot width: 60’
Max height: 35’
Min front yard
setback: 25’
Min interior
side yard
setback: 8’
Min spacing between
principal structures: 25’
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3209 Multiple-Family Residence 12 (RM-12)
Adopted September 2012, Amended Jan., Feb., and July 2013 City of Pompano Beach, Florida
Page 3-12 Zoning Code
155.3209. MULTIPLE-FAMILY RESIDENCE 12 (RM-12)
A. PURPOSE TYPICAL BUILDING TYPE The Multiple-Family Residence 12 (RM-12) district is established and intended to accommodate primarily
multifamily dwellings (including townhouse development) at moderate densities. The district also
accommodates single-family and two-family dwellings, zero-lot-line development, community residential
homes, assisted living facilities, and continuing care retirement communities. Limited neighborhood-
serving nonresidential uses, as well as office buildings with a floor area of 2,000 square feet or less, are
allowed as Special Exceptions.
B. USE STANDARDS See Appendix A: Consolidated Use Table, and use-specific standards in Article 4: Use Standards.
C. INTENSITY AND DIMENSIONAL STANDARDS 1
Lot area, minimum (sq ft) 7,0002 TYPICAL LOT PATTERN Lot width, minimum (ft) 60 2
Density, maximum (du/ac) 12 2,3
Floor area per dwelling unit, minimum (sq ft)
SF 950
2F 750
MF Efficiency units: 500
Other units: 650 + 100 per BR>1
Lot coverage, maximum (% of lot area) 60 2
Pervious area, minimum (% of lot area) 25 2
Height, maximum (ft) 35
Front yard setback, minimum (ft) 25
Street side yard setback, minimum (ft) 8 2,4
Setback from a waterway or canal, minimum (ft) 25
Setback from a dune vegetation line, minimum (ft) 25
Interior side yard setback, minimum (ft) 8 2,4,5
Rear yard setback, minimum (ft) 10 4
Spacing between principal structures, minimum (ft) 25
Required Front Yard, Pervious Area, minimum (% of
Required Front Yard) 50 (for Single Family Dwellings only)
Dimensional Standards for Accessory Structures See Accessory Use-Specific standards in Article 4: Part 3. NOTES: [sq ft = square feet; ft = feet; du/ac = dwelling units/acre; SF = single-family dwelling; 2F = two-family dwelling; MF = multifamily
dwelling; BR = bedroom]
1. See measurement rules and allowed exceptions/variations in Article 9:Part 4 .
2. For townhouse development, applies only to the development site as a whole, provided individual townhouse lots have a minimum area of
1,800 sq ft and a minimum width of 18 ft.
3. On land classified Residential by the Land Use Plan, maximum gross residential density may not exceed that established for the particular
land use classification.
4. Those portions of a structure extending above a height of 20 feet shall be set back an additional 1 ft for each 4 ft (or major fraction thereof)
the height of the portion of the structure exceeds 20 ft.
5. For developments with zero-lot-line single family dwellings, 0 ft along the zero lot line and 15 ft for the opposite interior side lot line.
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3209 Multiple-Family Residence 12 (RM-12)
City of Pompano Beach, Florida Adopted Sept. 2012; Amended Jan. 2013, Feb. 2013, & July 2013
Zoning Code Page 3-13
TYPICAL DEVELOPMENT CONFIGURATION
MULTIFAMILY DWELLING Min lot area = 7,000 sq ft
Max lot coverage = 60%
Min street
side yard
setback: 8’ Min front yard setback:
25’
Min lot width SF: 60’
Max height: 35’
Min spacing
between
principal
structures: 25’
Min front yard
setback: 25’
Min interior
side yard
setback: 8’
Min rear yard setback: 25’
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3210 Multiple-Family Residence 20 (RM-20)
Adopted September 2012, Amended Jan., Feb., and July 2013 City of Pompano Beach, Florida
Page 3-14 Zoning Code
155.3210. MULTIPLE-FAMILY RESIDENCE 20 (RM-20)
A. PURPOSE TYPICAL BUILDING TYPE The Multiple-Family Residence 20 (RM-20) district is established and intended to accommodate primarily
multifamily dwellings (including townhouse development) at moderate densities. The district also
accommodates single-family and two-family dwellings, zero-lot-line development, community residential
homes, assisted living facilities, and continuing care retirement communities. Limited neighborhood -
serving nonresidential uses, as well as office buildings, financial institutions, hotels/motels, and apartment
hotels, are allowed as Special Exceptions.
B. USE STANDARDS
See Appendix A: Consolidated Use Table, and use-specific standards in Article 4: Use Standards.
C. INTENSITY AND DIMENSIONAL STANDARDS 1
Lot area, minimum (sq ft) SF: 7,000 2F: 8,000 MF: 8,800 2 TYPICAL LOT PATTERN
Lot width, minimum (ft) SF: 60 2F: 70 MF: 75 2
Density, maximum (du/ac) 20 2,3
Floor area per dwelling unit, minimum (sq ft)
SF 950
2F 750
MF Efficiency units: 500
Other units: 650 + 100 per BR>1
Lot coverage, maximum (% of lot area) 60 2
Pervious area, minimum (% of lot area) 25 2
Height, maximum (ft) 35
Front yard setback, minimum (ft) 25
Street side yard setback, minimum (ft) 10 2,4
Setback from a waterway or canal, minimum (ft) 25
Setback from a dune vegetation line, minimum (ft) 25
Interior side yard setback, minimum (ft) 10 2,4,5
Rear yard setback, minimum (ft) 10 4
Spacing between principal structures, minimum (ft) 25
Required Front Yard, Pervious Area, minimum (% of
Required Front Yard) 50 (for Single Family Dwellings only)
Dimensional Standards for Accessory Structures See Accessory Use-Specific standards in Article 4: Part 3. NOTES: [sq ft = square feet; ft = feet; du/ac = dwelling units/acre; SF = single-family dwelling; 2F = two-family dwelling; MF = multifamily
dwelling; BR = bedroom]
1. See measurement rules and allowed exceptions/variations in Article 9:Part 4 .
2. For townhouse development, applies only to the development site as a whole, provided individual townhouse lots have a minimum area of
1,800 sq ft and a minimum width of 18 ft.
3. On land classified Residential by the Land Use Plan, maximum gross residential density may not exceed that established for the particular
land use classification.
4. Those portions of a structure extending above a height of 20 feet shall be set back an additional 1 ft for each 4 ft (or major fraction thereof)
the height of the portion of the structure exceeds 20 ft.
5. For developments with zero-lot-line single family dwellings, 0 ft along the zero lot line and 15 ft for the opposite interior side lot line.
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3210 Multiple-Family Residence 20 (RM-20)
City of Pompano Beach, Florida Adopted Sept. 2012; Amended Jan. 2013, Feb. 2013, & July 2013
Zoning Code Page 3-15
TYPICAL DEVELOPMENT CONFIGURATION
Min front yard setback: 25’
Max height: 35’
Min rear yard setback: 10’
Min interior side yard
setback: 10’
Min street side yard setback:
10’
Min lot width MF: 75’
MULTIFAMILY DWELLING Min lot area = 8,800 sq ft
Max lot coverage = 60%
Min spacing between
principal structures: 25’
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3211 Multiple-Family Residence 30 (RM-30)
Adopted September 2012, Amended Jan., Feb., and July 2013 City of Pompano Beach, Florida
Page 3-16 Zoning Code
155.3211. MULTIPLE-FAMILY RESIDENCE 30 (RM-30)
A. PURPOSE TYPICAL BUILDING TYPE The Multiple-Family Residence 30 (RM-30) district is established and intended to accommodate primarily
multifamily dwellings (including townhouse development) at moderately high densities. The district also
accommodates single-family and two-family dwellings, zero-lot-line development, community residential
homes, assisted living facilities, and continuing care retirement communities. Limited neighborhood-
serving nonresidential uses, as well as office buildings, financial institutions, hotels/motels, and apartment
hotels, are allowed as Special Exceptions
B. USE STANDARDS See Appendix A: Consolidated Use Table, and use-specific standards in Article 4: Use Standards.
C. INTENSITY AND DIMENSIONAL STANDARDS 1
Lot area, minimum (sq ft) SF: 7,000 2F: 8,000 MF: 8,800 2 TYPICAL LOT PATTERN Lot width, minimum (ft) SF: 60 2F: 70 MF: 75 2
Density, maximum (du/ac) 30 2,3
Floor area per dwelling unit, minimum (sq ft)
SF 950
2F 750
MF Efficiency units: 500
Other units: 650 + 100 per BR>1
Lot coverage, maximum (% of lot area) 60 2
Pervious area, minimum (% of lot area) 25 2
Height, maximum (ft) 105 4
Front yard setback, minimum (ft) 25
Street side yard setback, minimum (ft) 10 2,5
Setback from a waterway or canal, minimum (ft) 25
Setback from a dune vegetation line, minimum (ft) 25
Interior side yard setback, minimum (ft) 10 2,5,6
Rear yard setback, minimum (ft) 10 5
Spacing between principal structures, minimum (ft) 25
Required Front Yard, Pervious Area, minimum (% of
Required Front Yard) 50 (for Single Family Dwellings only)
Dimensional Standards for Accessory Structures See Accessory Use-Specific standards in Article 4: Part 3. NOTES: [sq ft = square feet; ft = feet; du/ac = dwelling units/acre; SF = single-family dwelling; 2F = two-family dwelling; MF = multifamily
dwelling; BR = bedroom]
1. See measurement rules and allowed exceptions/variations in Article 9:Part 4 .
2. For townhouse development, applies only to the development site as a whole; individual townhouse lots must have a minimum area of 1,800 sq
ft and a minimum width of 18 ft.
3. On land classified Residential by the Land Use Plan, maximum gross residential density may not exceed that established for the particular land
use classification.
4. Structures within the Air Park Overlay (APO) zoning district must also comply with the height limits in Section 155.3707.
5. Those portions of a structure extending above a height of 20 feet shall be set back an additional 1 ft for each 4 ft (or major fraction thereof) the
height of the portion of the structure exceeds 20 ft.
6. For developments with zero-lot-line single family dwellings, 0 ft along the zero lot line and 15 ft for the opposite interior side lot line.
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3211 Multiple-Family Residence 30 (RM-30)
City of Pompano Beach, Florida Adopted Sept. 2012; Amended Jan. 2013, Feb. 2013, & July 2013
Zoning Code Page 3-17
TYPICAL DEVELOPMENT CONFIGURATION
Min front yard setback: 25’
Min rear yard
setback: 10’
Min interior side yard
setback: 10’
Max height: 105’
Min lot width MF: 75’
Min spacing between principal
structures: 25’
Min street side yard setback:
10’
MULTIFAMILY DWELLING Min lot area = 8,800 sq ft
Max lot coverage = 60%
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3212 Multiple-Family Residence 45 (RM-45)
Adopted September 2012, Amended Jan., Feb., and July 2013 City of Pompano Beach, Florida
Page 3-18 Zoning Code
155.3212. MULTIPLE-FAMILY RESIDENCE 45 (RM-45)
A. PURPOSE TYPICAL BUILDING TYPE The Multiple-Family Residence 45 (RM-45) district is established and intended to accommodate
primarily multifamily dwellings (including townhouse development) at high densities. The district also
accommodates single-family and two-family dwellings, zero-lot-line development, community
residential homes, assisted living facilities, and continuing care retirement communities. Limited
neighborhood-serving nonresidential uses, as well as office buildings, financial institutions,
hotels/motels, and apartment hotels, are allowed as Special Exceptions.
B. USE STANDARDS See Appendix A: Consolidated Use Table, and use-specific standards in Article 4: Use Standards.
C. INTENSITY AND DIMENSIONAL STANDARDS 1
Lot area, minimum (sq ft) SF: 7,000 2F: 8,000 MF: 8,800 2 TYPICAL LOT PATTERN Lot width, minimum (ft) SF: 60 2F: 70 MF: 75 2
Density, maximum (du/ac) 45 2,3
Floor area per dwelling unit, minimum (sq ft)
SF 950
2F 750
MF Efficiency units: 500
Other units: 650 + 100 per BR>1
Lot coverage, maximum (% of lot area) 60 2
Pervious area, minimum (% of lot area) 25 2
Height, maximum (ft) 105 4,5
Front yard setback, minimum (ft) 25
Street side yard setback, minimum (ft) 10 2,6
Setback from a waterway or canal, minimum (ft) 25
Setback from a dune vegetation line, minimum (ft) 25
Interior side yard setback, minimum (ft) 10 2,6,7
Rear yard setback, minimum (ft) 10 6
Spacing between principal structures, minimum (ft) 25
Required Front Yard, Pervious Area, minimum (% of
Required Front Yard) 50 (for Single Family Dwellings only)
Dimensional Standards for Accessory Structures See Accessory Use-Specific standards in Article 4: Part 3. NOTES: [sq ft = square feet; ft = feet; du/ac = dwelling units/acre; SF = single-family dwelling; 2F = two-family dwelling; MF = multifamily
dwelling; BR = bedroom]
1. See measurement rules and allowed exceptions/variations in Article 9:Part 4 .
2. For townhouse development, applies only to the development site as a whole, provided individual townhouse lots have a minimum area of
1,800 sq ft and a minimum width of 18 ft.
3. On land classified Residential by the Land Use Plan, maximum gross residential density may not exceed that established for the particular land
use classification.
4. Structures within the Air Park Overlay (APO) zoning district must also comply with the height limits in Section 155.3707.
5. Not applicable within a Multiple-Family Residence45 High-Rise (RM-45 HR) Overlay district.
6. Those portions of a structure extending above a height of 20 feet shall be set back an additional 1 ft for each 4 ft (or major fraction thereof) the
height of the portion of the structure exceeds 20 ft.
7. For developments with zero-lot-line single family dwellings, 0 ft along the zero lot line and 15 ft for the opposite interior side lot line.
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3212 Multiple-Family Residence 45 (RM-45)
City of Pompano Beach, Florida Adopted Sept. 2012; Amended Jan. 2013, Feb. 2013, & July 2013
Zoning Code Page 3-19
TYPICAL DEVELOPMENT CONFIGURATION
Max height: 105’
Min setback from
dune vegetation
line: 25’
Min front yard setback:
25’
Min street side
yard setback:
10’
Min lot width MF: 75’
Min interior
side yard
setback: 10’
MULTIFAMILY DWELLING Min lot area = 8,800 sq ft
Max lot coverage = 60%
Article 3: Zoning Districts
Part 2 Residential Base Zoning Districts
Section 155.3213 Mobile Home Park (MH-12)
Adopted September 2012, Amended Jan., Feb., and July 2013 City of Pompano Beach, Florida
Page 3-20 Zoning Code
155.3213. MOBILE HOME PARK (MH-12)
A. PURPOSE TYPICAL BUILDING TYPE
The Mobile Home Park (MH-12) district is established and intended to accommodate mobile home
parks that primarily function to provide spaces for individual mobile homes intended to be occupied as
permanent living quarters. The district also accommodates recreational facilities and other accessory
uses serving occupants of the mobile home park.
B. USE STANDARDS
See Appendix A: Consolidated Use Table, and use-specific standards in Article 4: Use Standards.
C. INTENSITY AND DIMENSIONAL STANDARDS 1
Lot area, minimum (acres) 5 TYPICAL LOT PATTERN
Lot width, minimum (ft) 300
Density, maximum (du/ac) 12 2
Height, maximum (ft) 12
Setback from a waterway or canal, minimum (ft) 25
Front yard setback per mobile home space, minimum (ft) 25 3
Street side yard setback per mobile home space, minimum (ft) 10 3
Interior side yard setback per mobile home space, minimum (ft) 10 3
Rear yard setback per mobile home space, minimum (ft) 15 3
Spacing between mobile homes, minimum (ft) 10 3
Dimensional Standards for Accessory Structures See Accessory Use-Specific standards in Article 4: Part 3. NOTES: [sq ft = square feet; ft = feet; du/ac = dwelling units/acre]
1. See measurement rules and allowed exceptions/variations in Article 9:Part 4 .
2. On land classified Residential by the Land Use Plan, maximum gross residential density may not exceed that established for the particular land use
classification.
3. If the mobile home park was zoned R-1T under former county zoning and consists of mobile home spaces that are individually owned or leased for
terms of one year or more, the minimum front and street side yard setbacks are 6 ft, the interior side yard setback is 4 ft, the rear yard setback is 8 ft, and
the interior side yard setback for roofed carports is 2 ft.
4. 25 ft between a mobile home and any accessory or service structure used in conjunction with the park.
TYPICAL DEVELOPMENT CONFIGURATION
Max height: 35’
Min street side
yard setback: 10’
Min front yard setback:
25’
Min lot width MF: 300’ Min rear yard
setback: 15’
Min interior
side yard
setback: 10’