"Energy solutions with 'best in class' gas engine technology"
2G 2G -- The Way Biogas CHP was Meant to BeThe Way Biogas CHP was Meant to Be
2G EnergieTechnik
"Energy solutions with 'best in class' gas engine technology"
• Gas engine based CHP and other distributed generation systems– 50-500 kW with 2G optimized MAN gas engines
– 500-4400 kW with 2G packaged Jenbacher gas engines
– 30-1000 kW with Capstone MicroTurbines
• Emission control technology– HUG/Miratech/COdiNOx
• System management– Tenergy Services North America
• Operation and Maintenance– Parts, Service, Plant operation
– Cross Canada Service Network
EPS Business Overview
"Energy solutions with 'best in class' gas engine technology"
2011 Delivery Program - 60 Hz – 2G Biogas
Model Electrical Output1)
ekW
Thermal
Output2)
kW
Total
Output
kW
Electrical Efficiency (LHV)
%
Thermal Efficiency
%
System Efficiency
%
2G-KWK-100BGG4) 100 140 240 36.4 51.0 87.4
2G-KWK-190BGG4) 190 237 427 36.4 45.3 81.7
2G-KWK-250BGG4) 250 269 519 39.5 42.0 82.8
2G-KWK-370BGG4) 370 458 828 36.9 45.8 82.7
2G-KWK-500BGG5) 500 634 1134 36.6 46.4 83.0
2G-KWK-633BGG5) 633 787 1420 38.1 47.4 85.5
2G-KWK-850BGG5) 850 918 1768 40.1 43.3 83.4
2G-KWK-1060BGG5) 1060 1272 2332 39.0 46.7 85.7
2G-KWK-1135BGG5) 1135 1225 1360 40.2 43.4 83.6
2G-KWK-1425BGG5) 1425 1535 2960 40.3 43.4 83.7
2G-KWK-1625BGG5) 1625 1652 3277 42.0 42.7 84.8
2G-KWK-2175BGG5) 2175 2206 4381 42.1 42.7 84.9
2G-KWK-2725BGG5) 2725 2750 5475 42.3 42.7 85.0
1) As measured at the generator terminals
2) Exhaust cooled to 120oC
3) Water cooled enclosure
4) Prime mover is MAN gas engine
5) Prime mover is Jenbacher gas engine
• All data measured at full load, subject to technical modifications and change
• Electrical output based on ISO standards and conditions in accordance with
ISO3046/1-1991 and VDE-0530 with respective tolerances
"Energy solutions with 'best in class' gas engine technology"
We supply, service and operate CHP systems, providing project developers, plant operators & end-users with “Best-In-Class” energy solutions.
Our Area of ExpertiseOur Area of Expertise
EPS Area of Expertise
"Energy solutions with 'best in class' gas engine technology"
Business as UsualPackaging the North-American Way
"Energy solutions with 'best in class' gas engine technology"
Customers are seeking:• High quality design, packaging and component
selection, suitable for 20 year project life
• Reliable system operation (maximize revenues)
• Predictable operating and maintenance cost (minimize O&M cost)
• High electrical and thermal efficiencies (minimize fuel cost)
What Customers Really Want
"Energy solutions with 'best in class' gas engine technology"
Pump & CirculationCompartment
Electronic ControlSection
Heat ExchangerCompartment
Heat Exchanger and Exhaust System
Compartment
The CHP Module
"Energy solutions with 'best in class' gas engine technology"
Pump & CirculationCompartment
Electronic ControlSection
Heat ExchangerCompartment
Special Sound AttenuatedEnclosure for Inside Installation
The CHP Module
"Energy solutions with 'best in class' gas engine technology"
Fully Containerized & Sound Attenuated CHP Modules
The entire CHP Plant in one Container.
Containerized CHP Modules
"Energy solutions with 'best in class' gas engine technology"
®
Agenitor 306Best in Class 250 kW CHP System
"Energy solutions with 'best in class' gas engine technology"
Increased Revenue Potential of Optimized Gas Engine Technology
Model 2G JMS312(reduced pwr)
2G-KWK-250-BGGStandard V8
Twin-pack with 2 x agenitor 306
Quantity: 1 2 2
Power Output (kW) 500 kW 500 kW 500 kW
Thermal Output (kW) 634 kW 648 538
Thermal Output (btu/hr) 2,165,254 2,213,036 1,838,000
Fuel Consumption (kW) 1,366 1,388 1,266
Fuel Consumption (btu/hr) 4,666,313 4,740,268 4,323,617
Electrical Efficiency (%) 36.6 36 39.5
Thermal Efficiency (%) 46.4 46.8 42.0
Total Efficiency (%) 83 82.8 81.5
Cost of ownership – capital + maintenance (20 yrs)
$1,956,967 $2,217,475 $1,970,287
Fuel savings (m3/yr) 29,046 0 163,642
Fuel savings (m3 in 20 yr) 580,920 0 3,272,840
Revenue potential of fuel saved ($0.16/kWh):
$211,027 $1,283,143
"Energy solutions with 'best in class' gas engine technology"
First Major Overhaul 60,000 Hours
First Top-End Overhaul 30,000 Hours
Systems Designed for Maximum Durability and Reliability