15 / 25 kV AC VOLTAGE SENSOR Type TMS - Sécheron · TMS Voltage sensor MACS AC vacuum...

4
15 / 25 kV AC VOLTAGE SENSOR Type TMS ELECTRICAL SAFETY SOLUTIONS / RAIL VEHICLES

Transcript of 15 / 25 kV AC VOLTAGE SENSOR Type TMS - Sécheron · TMS Voltage sensor MACS AC vacuum...

Page 1: 15 / 25 kV AC VOLTAGE SENSOR Type TMS - Sécheron · TMS Voltage sensor MACS AC vacuum circuit-breaker MODBOX® High voltage integrated system RS Roof switch REMTrain Energy Meter

15 / 25 kVAC VOLTAGE SENSOR Type TMS

ELECTRICAL SAFETY SOLUTIONS /

RAIL VEHICLES

Page 2: 15 / 25 kV AC VOLTAGE SENSOR Type TMS - Sécheron · TMS Voltage sensor MACS AC vacuum circuit-breaker MODBOX® High voltage integrated system RS Roof switch REMTrain Energy Meter

SA Surge arresterImes Current sensorTMS Voltage sensorMACS AC vacuum circuit-breakerMODBOX® High voltage integrated systemRS Roof switchREM Energy meter

Secheron Hasler Group products

SA 1

SA 2

AC

MO

DBO

RS

MACS

TMS REM

AC voltage

Imes

SA Surge arresterImes Current sensorTMS Voltage sensorMACS AC vacuum circuit-breakerMODBOX® High voltage integrated systemRS Roof switchREM Energy Meter

Secheron Hasler Group products

2 TRACTION MEASUREMENT SYSTEM TYPE TMS FOR 15 & 25 KVAC ROLLING STOCK

GENERAL INFORMATION

MAIN BENEFITSMAIN BENEFITS

Sécheron TMS is an evolutive Traction Measurement System dedicated to rolling stock applications and used for different functions including voltage detection, traction control, traction protection and energy measurement.The configuration proposed in this document covers the Voltage Measurement Function (VMF) as specified

in the standards EN50463-2/ IEC62888-2 for on board energy measurement. TMS measures the supply voltage of 15 kVAC and 25 kVAC traction systems, and transmits safe isolated and accurate signals to different on-board equipments.

APPLICATIONS, TYPICAL EXAMPLES

Traction circuits

Train roof line

AC

MO

DB

OX

®

Traincontrol

Traction protection

relay

MAIN FEATURES• Measurement of 15 kVAC & 25 kVAC signals.• Insulation voltage 31.5 kVAC. • Impulse withstand voltage 170 kV.• Suitable for energy measurement-

Accuracy class 0.5R.

• 3 isolated analog outputs, current loop type.• Suitable for indoor or outdoor installation.• Reference standards EN50463-2/ IEC62888-2,

EN50124-1/IEC62497-1, EN/IEC61373. EN50155, EN45545-2.

Certified TSI Loc&Pass according to EN50463-2/IEC62888-2.

No delay between input and output signal - Suitable for Traction Control & Protection.

Current loop transmission for noise immunity.

Output signal with optional offset for safety critical applications.

Output signal of DC input voltage can also be used for third party AC/DC voltage detection.

Compact (height : 381 mm) & lightweight (17 kg).

Safe against internal arcs.

Horizontal or vertical mounting.

Sécheron high expertise in 15 & 25 kVAC systems (AC circuit-breakers, roof switches, High Voltage Integrated System type AC MODBOX®).

Can be delivered as a stand-alone component, or integrated in Sécheron AC MODBOX® with other Sécheron high-voltage components.

Can be delivered as stand-alone component or in the complete package of Sécheron Hasler Group Train Energy Management System.

Page 3: 15 / 25 kV AC VOLTAGE SENSOR Type TMS - Sécheron · TMS Voltage sensor MACS AC vacuum circuit-breaker MODBOX® High voltage integrated system RS Roof switch REMTrain Energy Meter

3TRACTION MEASUREMENT SYSTEM TYPE TMS FOR 15 & 25 KVAC ROLLING STOCK

DATA FOR PRODUCT SELECTIONSymbol Unit 15 kV 25 kV

MAIN HIGH VOLTAGE CIRCUITRated voltage Un, VMF [kVAC] 15 25Rated frequency fn [HZ] 16.7 50 & 60Maximum permanent measured voltage [kVAC] 17.25 31.5Maximum peak measured voltage UMAX, VMF [kV] 50Rated insulation Voltage UNm [kVAC] 31.5Impulse withstand voltage UNi [kV] 170Rated power frequency withstand voltage (50Hz/60s) U50 [kVAC] 80Overvoltage category OV 4

LOW VOLTAGE CIRCUITSAnalog outputsNumber of outputs 3Current loop output type B (Bipolar) or O (Offset)Output current (refer to graphics page 4) Bipolar Output Type Offset Output Type- DC offset [mA] 0 30- AC gain [mA/kV] 1 0.4Measuring resistance RMU [Ω] 10 to 200Maximum peak voltage on measuring resistance [V] ±10Accuracy class 0.5RRated delay time between input & output signal (1) tdn [µs] 0Rated power frequency withstand voltage (50Hz/60s) U50 [kVAC] 1.5(against earth and between outputs)

(1) According to EN/IEC60044-7.

Auxiliary supplyAuxiliary supply voltage Un [VDC] 24 to 110Auxiliary supply voltage range [VDC] 0.7 Un - 1.25 Un

Auxiliary supply power [W] <10Rated power frequency withstand voltage (50Hz/60s) U50 [kVAC] 1.5

Low voltage interfaceConnector type Harting Han® HPR (Outdoor)

OPERATING CONDITIONSInstallation Indoor /outdoorAltitude [m] ≤ 2000Working ambient temperature Tamb [°C] -40 to + 70Pollution degree PD4Protection Index (low voltage circuit) [IP] 67

+

-

X1a1

X1a2

+

-

X1a3

X1a4

+

-

X1b1

X1b2

X1c1

X1c2

+ BAT

- BAT

=

=

=

=

RMU 1

RMU 2

RMU 3

HV connectionIsolator

High Voltage Input

Auxiliary SupplyEarth connection

LV housing

LV connector

PRODUCT STRUCTURE & FUNCTIONAL SCHEME

TMS

Page 4: 15 / 25 kV AC VOLTAGE SENSOR Type TMS - Sécheron · TMS Voltage sensor MACS AC vacuum circuit-breaker MODBOX® High voltage integrated system RS Roof switch REMTrain Energy Meter

Copyright© 2018 Sécheron SA

This document is not contractual and contains information corresponding to the level of technology at the date of printing. Sécheron reserves the right to modify and/or improve the product, whose characteristics are described in these documents, as required by new technology at any time. It is the purchaser’s responsibility to inform himself, no matter what the circumstances, of the product’s maintenance conditions and requirements. Sécheron reserves all rights, especially those arising from our “General Delivery Conditions”.

SA00

4770

BEN

_A01

-10.

18

Sécheron SA Rue du Pré-Bouvier 251242 Satigny - GenevaCH-Switzerland

Tel: +41 22 739 41 11Fax: +41 22 739 48 [email protected]

PRODUCT INTEGRATION

PRODUCT CODIFICATION

DIMENSIONS

ANALOG OUTPUT CONFIGURATIONS

D i m e n s i o n s w i t h o u t tolerances are indicative. All dimensions are in mm. The maximum allowed flatness deviation of the support frame is 1 mm.

Keep clear

Ø256A

Ø65

4771 32

381

12

373

181

LV connector HV connection

Bipolar type current output Offset type current output

A

275244

Ø40

M10

M12

21

275

21

34

244

4XM

8

4XØ11

Harting HAN

HartingHAN HPR

Line Description Designation Standard OptionsCustomer’s

choice10 Product type TMS TMS TMS11 Configuration UNi = 170kV A A12 Voltage Measurement Function - Accuracy class 0.5R

- Input voltages 25 kV / 50-60 Hz & 15 kV / 16.7 Hz 125 kV / 50 Hz 225 kV / 60 Hz 3

15 kV / 16.7 Hz 425 kV / 50 Hz & 15 kV / 16.7 Hz 6

25 kV / 50-60 Hz 719 Spare digit Not applicable Z Z14 Voltage Measurement Function output configuration 1B (Bipolar) + 2O (Offset) A

2B (Bipolar) + 1O (Offset) B3 B C3 O D

15 Low Voltage connector type Harting Han® HPR 1 1

Pla

ce a

nd d

ate:

N

ame:

S

igna

ture

:

-35

t

35

0

25

-25

-35

t

35

0

25

-25

-35

t 0

-25

t

30

0

44

3525

40

16

INPU

T VO

LTA

GE

(kV)

OU

TPU

T C

UR

REN

T(m

A)

INPU

T VO

LTA

GE

(kV)

OU

TPU

T C

UR

REN

T(m

A)