1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4...

16
Industrial Enclosures 1418J Series - NEMA 12 Large JIC Enclosures Application Designed to house electrical, electronic, hydraulic or pneumatic controls and instruments. Provides a degree of protection from falling dirt, dust, oil and water. Standards UL 508 Type 12 Complies with NEMA Type 12 JIC EGP-1-1967 unless marked 1 IEC 529, IP65 Construction Formed from 14 gauge steel. Smooth, continuously welded seams without knockouts, cutouts or holes. Door and body stiffeners are provided in the larger enclosures for extra rigidity. Welded brackets provide for enclosure mounting. Continuously hinged cover is secured with stainless steel screws, threaded into sealed wells. Oil resistant gaskets are permanently secured and mechanically retained. A removable 12 gauge inner panel is included. Collar studs are provided for mounting inner panels. A grounding stud is provided in the enclosure and a bonding stud is provided on the door. A literature pocket is provided for the inside of the door. Finish Cover and enclosure are phosphatized and finished in ANSI/ ASA 61 gray recoatable powder coating. Removable inner panel is finished in white powder coating. Accessories Additional inner panels...see page 384 Blowers...see page 359 Breather kits...see page 374 Filter fans...see page 360-367 Heaters...see page 369-371 Louvered ventilating plates...see page 396 Terminal kit assemblies...see page 386 Thermostats...see page 374 Window kits...see page 391 Junction Boxes Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Transcript of 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4...

Page 1: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

Ind

ustrial En

closures

1418J Series - NEMA 12Large JIC Enclosures

ApplicationDesigned to house electrical,electronic, hydraulic or pneumaticcontrols and instruments.Provides a degree of protection fromfalling dirt, dust, oil and water.

StandardsUL 508 Type 12Complies with

NEMA Type 12JIC EGP-1-1967 unless marked1

IEC 529, IP65

ConstructionFormed from 14 gauge steel.Smooth, continuously welded seamswithout knockouts, cutouts or holes.Door and body stiffeners areprovided in the larger enclosures forextra rigidity.Welded brackets provide forenclosure mounting.Continuously hinged cover issecured with stainless steel screws,threaded into sealed wells.Oil resistant gaskets arepermanently secured andmechanically retained.A removable 12 gauge inner panel isincluded.Collar studs are provided formounting inner panels.A grounding stud is provided in theenclosure and a bonding stud isprovided on the door.A literature pocket is provided for theinside of the door.

FinishCover and enclosure arephosphatized and finished in ANSI/ASA 61 gray recoatable powdercoating.Removable inner panel is finished inwhite powder coating.

AccessoriesAdditional inner panels...see page 384Blowers...see page 359Breather kits...see page 374Filter fans...see page 360-367Heaters...see page 369-371Louvered ventilating plates...see page 396Terminal kit assemblies...see page 386Thermostats...see page 374Window kits...see page 391

Jun

ction

Boxes

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 2: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

Ind

ustrial En

closures

When A= M=

30 7.00

36 9.0042 9.88

48 11.38

Panel Dimensions Centers ShipPart No. A B C D E F G H J Wt. lbs

1418JB7 16 12 7 13 9 6 17.25 0.88 0.50 30

1418JC7 20 16 7 17 13 10 21.25 0.88 0.88 381418JD7 20 20 7 17 17 14 21.25 0.88 0.50 45

1418JE7 24 20 7 21 17 14 25.25 0.88 0.50 541418JJ7 24 24 7 21 21 18 25.25 0.88 0.50 63

1418JF7 30 20 7 27 17 14 31.25 0.88 0.50 701418JK7 30 24 7 27 21 18 31.25 0.88 0.50 78

1418JL7 36 24 7 33 21 18 37.25 0.88 0.50 901418JC9 20 16 9 17 13 10 21.25 0.88 0.50 42

1418JD9 20 20 9 17 17 14 21.25 0.88 0.50 451418JE9 24 20 9 21 17 14 25.25 0.88 0.50 60

1418JJ9 24 24 9 21 21 18 25.25 0.88 0.50 671418JK9 30 24 9 27 21 18 31.25 0.88 0.50 85

1418JF9 30 20 9 27 17 14 31.25 0.88 0.50 701418JM9 36 30 9 33 27 24 37.25 1.38 1.38 120

1418JL9 36 24 9 33 21 18 37.25 0.88 0.50 1001418JO91 42 30 9 39 27 24 43.25 1.38 1.38 137

1418JP91 42 36 9 39 33 30 43.25 1.38 1.38 1651418JJ11 24 24 11 21 21 18 25.25 0.88 0.50 73

1418JL11 36 24 11 33 21 18 37.25 0.88 0.50 1071418JS111 48 36 11 45 33 30 49.25 1.38 1.38 187

1418JK13 30 24 13 27 21 18 31.25 0.88 0.50 941418JM13 36 30 13 33 27 24 37.25 1.38 1.38 1311 Does not meet JIC requirements

Side View

Front View

Top View

Section Z-Z

Jun

ction

Boxes/JIC

Enclo

sures

➊➊ ➊➊ ➊

➋➋ ➋➋ ➋ ➌➌ ➌➌ ➌

➍➍ ➍➍ ➍

➎➎ ➎➎ ➎

➏➏ ➏➏ ➏

➊ Vertical body stiffener req’d on M only

➋ Omit if center body stiffener if A is lessthan 41"

➌ Omit if A is less than 31"

➍ Omit 2 center studs if A is less than 31"

➎ Omit body stiffeners if B is less than 29"

➏ Omit 2 middle studs if B is less than 31"

➐ Omit door stiffener if A or B is 24" orless

1418J Series - NEMA 12Large JIC Enclosures

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 3: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

Wallm

ou

nt En

closu

res

1418 Series 304 Stainless Steel Single Door Enclosures - NEMA 4XContinuous Hinge, Clamped Cover

ApplicationDesigned for use as instrumentenclosures, electric, hydraulic orpneumatic control housings,electrical junction boxes or terminalwiring enclosures.Provides protection whereequipment may be hosed down orotherwise be very wet, or in specificapplications where corrosion is aserious problem.

StandardsUL 508 Type 3R, 4, 4X, and 12CSA Type 3R, 4, 4X, and 12Complies with

NEMA Type 3R, 4, 4X, 12 and 13JIC EGP-1-1967 unless marked1

IEC 529, IP66

ConstructionFormed 14 gauge Type 304stainless steel bodies and doors.Smooth, continuously welded seamswithout knockouts, cutouts or holes.Door and body stiffeners areprovided in the larger enclosures forextra rigidity.Welded brackets provide forenclosure mounting.Formed lip on door and enclosureexcludes flowing liquids andcontaminants.Stainless steel continuous hinge ondoor may be removed by pulling thestainless steel hinge pin.Door is secured with easily operatedstainless steel clamps.Provision for padlocking.Oil resistant gaskets are permanentlysecured.A removable 12 gauge inner panelis included.Collar studs are provided formounting inner panels.A bonding stud is provided on thedoor and a grounding stud isprovided in the enclosure.A literature pocket is provided for theinside of the door.

FinishCover and enclosure are naturalstainless steel with a smoothbrushed finish.Removable inner panel is finished inwhite powder coating.

AccessoriesAdditional inner panels...see page 384Air conditioners...see page 348-357Blowers...see page 359Breather kits...see page 374Door clamping hardware...see page 378Door stop kits...see page 393Drip shield kits...see page 393Enclosure stabilizers...see page 397Filter fans...see page 360-367Floor stand kits...see page 394Heaters...see page 369-371Lock kit...see page 379Louvered ventilating plates...see page 396Quick release clamp...see page 378Terminal kit assemblies...see page 386Thermostats...see page 374Window kits...see page 391

InnerPanel

Included

New Sizes

Available!New Sizes

Available!

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 4: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

Wallm

ou

nt En

closu

res

Side View

Section Y-Y

Section Z-Z

Front View

➊ Vertical stiffener required on KK, LL & M only.➋ Omit center body stiffener if A is less than 41".➌ Padlocking hasp and staple.➍ Omit 2 middle studs if A is less than 31".➎ Omit body stiffeners if A or B is less than 29".➏ Omit 2 middle studs if B is less than 31".➐ Omit door stiffener if A or B is less than 31"

except if AxB is 42"x30".

Literature pocket supplied loose.Number of door clamps varies to enclosure size.

When A= M=

30 7.0036 9.0042 9.8848 11.3860 14.38

1418 Series 304 Stainless Steel Single Door Enclosures - NEMA 4XContinuous Hinge, Clamped Cover

Panel Size Mtg.Centers ShipPart No. A B C D E F G Wt. lbs.

1418N4SSM8 36 30 8 33 27 24 37.25 1211418N4SSP81 42 36 8 39 33 30 43.25 1771418N4SSS81 48 36 8 45 33 30 49.25 2071418N4SSC10 20 16 10 17 13 10 21.25 471418N4SSE10 24 20 10 21 17 14 25.25 661418N4SSK10 30 24 10 27 21 18 31.25 1201418N4SSL10 36 24 10 33 21 18 37.25 1081418N4SSM10 36 30 10 33 27 24 37.25 1251418N4SSO101 42 30 10 39 27 24 43.25 1751418N4SSS101 48 36 10 45 33 30 49.25 2151418N4SSJ12 24 24 12 21 21 18 25.25 711418N4SSK12 30 24 12 27 21 18 31.25 951418N4SSM12 36 30 12 33 27 24 37.25 1361418N4SSLL121 36 36 12 33 33 30 37.25 2021418N4SSS121 48 36 12 45 33 30 49.25 2251418N4SST121 60 36 12 57 33 30 61.25 2701418N4SSK16 30 24 16 27 21 18 31.25 1001418N4SSM16 36 30 16 33 27 24 37.25 1491418N4SSS161 48 36 16 45 33 30 49.25 2901418N4SST161 60 36 16 57 33 30 61.25 2801 Does not meet JIC requirements 2 Flat panel

Panel Size Mtg.Centers ShipPart No. A B C D E F G Wt. lbs.

1418N4SSB62 16 12 6 13 9 9.5 17.25 281418N4SSG62 16 16 6 13 13 10.0 17.25 301418N4SSCR62 16 20 6 13 17 14.0 17.25 381418N4SSC62 20 16 6 17 13 10.0 21.25 381418N4SSD62 20 20 6 17 17 14.0 21.25 401418N4SSE6 24 20 6 21 17 14.0 25.25 611418N4SSJ6 24 24 6 21 21 18.0 25.25 651418N4SSB8 16 12 8 13 9 9.5 17.25 321418N4SSC82 20 16 8 17 13 10.0 21.25 381418N4SSD82 20 20 8 17 17 14.0 21.25 521418N4SSER8 20 24 8 17 21 18.0 21.25 611418N4SSH8 24 16 8 21 13 10.0 25.25 611418N4SSE8 24 20 8 21 17 14.0 25.25 611418N4SSJ8 24 24 8 21 21 18.0 25.25 751418N4SSKR8 24 30 8 21 27 24.0 25.25 891418N4SSF8 30 20 8 27 17 14.0 31.25 721418N4SSK8 30 24 8 27 21 18.0 31.25 891418N4SSKK8 30 30 8 27 27 24.0 31.25 1001418N4SSL8 36 24 8 33 21 18.0 37.25 1001 Does not meet JIC requirements 2 Flat panel

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 5: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

1418 Series Single Door Aluminum Enclosures - NEMA 4Continuous Hinge, Clamped Cover

InnerPanel

Included

ApplicationDesigned for use as instrumentenclosures, electric, hydraulic orpneumatic control housings,electrical junction boxes or terminalwiring enclosures.Provides protection whereequipment may be hosed down orotherwise be very wet, or in specificapplications where corrosion may bea problem.

StandardsUL 508 Type 4 and 12 as marked1

CSA Type 4 and 12Complies with

NEMA Type 4, 12 and 13JIC EGP-1-1967IEC 529, IP66

ConstructionFormed from 0.10" Type 5052 H-32aluminum.Smooth, continuously welded seamswithout knockouts, cutouts or holes.Door and body stiffeners areprovided in the larger enclosures forextra rigidity.Welded brackets provide forenclosure mounting.Formed lip on door and enclosureexcludes flowing liquids andcontaminants.Aluminum continuous hinge on doormay be removed by pulling thealuminum hinge pin.Door is secured with easily operatedaluminum clamps.Provision for padlocking.Oil resistant gaskets arepermanently secured.A removable 12 gauge inner panel isincluded.Collar studs are provided formounting inner panels.A bonding stud is provided on thedoor and a grounding stud isprovided in the enclosure.A literature pocket is provided for theinside of the door.

FinishCover and enclosure are naturalunfinished aluminum.Removable inner panel is finished inwhite powder coating.

AccessoriesAdditional inner panels...see page 384Breather kits...see page 374Door stop kits...see page 393Heaters...see page 369-371Lock kit...see page 379Terminal kit assemblies...see page 386Thermostats...see page 374Window kits...see page 391

Wallm

ou

nt En

closu

res

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 6: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

1418 Series Single Door Aluminum Enclosures - NEMA 4Continuous Hinge, Clamped Cover

Panel Size Mtg. Centers ShipPart No. A B C D E F G Wt. lbs.

1418N4ALB61, 2 16 12 6 13 9 9.5 17.25 14

1418N4ALC61, 2 20 16 6 17 13 10.0 21.25 161418N4ALE61 24 20 6 21 17 14.0 25.25 21

1418N4ALJ8 24 24 8 21 21 18.0 25.25 261418N4ALK8 30 24 8 27 21 18.0 31.25 39

1418N4ALM8 36 30 8 33 27 24.0 37.25 421418N4ALS8 48 36 8 45 33 28.0 49.25 56

1418N4ALC101, 2 20 16 10 17 13 10.0 21.25 191418N4ALE101 24 20 10 21 17 14.0 25.25 24

1418N4ALK12 30 24 12 27 21 18.0 31.25 361418N4ALM12 36 30 12 33 27 24.0 37.25 47

1418N4ALT12 60 36 12 57 33 30.0 61.25 831 Meets UL standards 2 Flat panel

Section Z-Z

When A= M=

30 7.0036 9.0042 9.8848 11.3860 14.38

Section Y-Y

Front View Section X-X

➊ Vertical stiffener required on M only.➋ Omit center body stiffener if A is less than 41".➌ Padlocking hasp and staple➍ Omit 2 middle studs if A is less than 31".➎ Omit body stiffeners if A or B is less than 29".➏ Omit 2 middle studs if B is less than 31".➐ Omit door stiffener if A or B is less than 31".

Wallm

ou

nt En

closu

res

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 7: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

Ind

ustrial En

closu

res

FinishCover and enclosure are finished inrecoatable smooth ANSI/ASA 61 graypowder coating on the outside, withwhite powder coating on the inside.Removable inner panel is finishedin white powder coating.

AccessoriesAdditional inner panels...see page 384Air conditioners...see page 348-357Blowers...see page 359Breather kits...see page 374Door clamping hardware...see page 378Door stop kits...see page 393Drip shield kits...see page 393Enclosure stabilizers...see page 397Filter fans...see page 360-367Floor stand kits...see page 394Heaters...see page 369-371Lock kit...see page 379Louvered ventilating plates...see page

396Quick release clamp...see page 378Terminal kit assemblies...see page 386Thermostats...see page 374Window kits...see page 391

1418 Series Single Door Enclosures - NEMA 12, 13Continuous Hinge, Clamped Cover

ApplicationDesigned to house electrical,electronic, hydraulic or pneumaticcontrols and instruments.Provides a degree of protection fromfalling dirt, dust, oil and water.

StandardsUL 508 Type 12 and 13CSA Type 12 and 13Complies with

ConstructionFormed 14 gauge steel bodies anddoors.Smooth, continuously weldedseams without knockouts, cutouts orholes.Door and body stiffeners areprovided in the larger enclosures forextra rigidity.Welded brackets provide forenclosure mounting.Formed lip on door and enclosureexclude flowing liquids andcontaminants.Continuously hinged door may beremoved by pulling the hinge pin.Door is secured with easily operatedstainless steel clamps.Provision for padlocking.Oil resistant gaskets arepermanently secured andmechanically retained.A removable 12 gauge inner panel isincluded.Collar studs are provided formounting inner panels.A bonding stud is provided on thedoor and a grounding stud isprovided in the enclosure.A literature pocket is provided for theinside of the door.

Panel Size Centers ShipPart No. A B C D E F G Wt. lbs

1418A62 12 24 6 9 21 18.0 13.25 34

1418B62 16 12 6 13 9 9.5 17.25 261418G62 16 16 6 13 13 10.0 17.25 32

1418CR62 16 20 6 13 17 14.0 17.25 381418CA62 20 12 6 17 9 9.5 21.25 32

1418C62 20 16 6 17 13 10.0 21.25 381418D62 20 20 6 17 17 14.0 21.25 48

1418ER6 20 24 6 17 21 18.0 21.25 541418AR62 24 12 6 21 9 9.5 25.25 36

1418H6 24 16 6 21 13 10.0 25.25 461418E6 24 20 6 21 17 14.0 25.25 54

1418J6 24 24 6 21 21 18.0 25.25 621418FG6 30 16 6 27 13 10.0 31.25 56

1418F6 30 20 6 27 17 14.0 31.25 661418K6 30 24 6 27 21 18.0 31.25 76

1418L6 36 24 6 33 21 18.0 37.25 911418M6 36 30 6 33 27 24.0 37.25 114

1418A82 12 24 8 9 21 18.0 13.25 381418B82 16 12 8 13 9 9.5 17.25 28

1418G82 16 16 8 13 13 10.0 17.25 341418CR82 16 20 8 13 17 14.0 17.25 43

1418CA82 20 12 8 17 9 9.5 21.25 351418C82 20 16 8 17 13 10.0 21.25 401 Does not meet JIC requirements 2 Flat Panel

Panel Size Centers ShipPart No. A B C D E F G Wt. lbs

1418D82 20 20 8 17 17 14.0 21.25 48

1418ER8 20 24 8 17 21 18.0 21.25 611418AR8 24 12 8 21 9 9.5 25.25 40

1418H8 24 16 8 21 13 10.0 25.25 501418E8 24 20 8 21 17 14.0 25.25 58

1418J8 24 24 8 21 21 18.0 25.25 681418KR8 24 30 8 21 27 24.0 25.25 82

1418KA8 30 12 8 27 9 9.5 31.25 501418KG8 30 16 8 27 13 10.0 31.25 60

1418F8 30 20 8 27 17 14.0 31.25 701418K8 30 24 8 27 21 18.0 31.25 82

1418KK8 30 30 8 27 27 24.0 31.25 1021418MR8 30 36 8 27 33 30.0 31.25 124

1418L8 36 24 8 33 21 18.0 37.25 961418M8 36 30 8 33 27 24.0 37.25 120

1418LL81 36 36 8 33 33 30.0 37.25 1421418N8 42 24 8 39 21 18.0 43.25 110

1418O81 42 30 8 39 27 24.0 43.25 1321418P81 42 36 8 39 33 30.0 43.25 182

1418Q8 48 24 8 45 21 18.0 49.25 1221418R81 48 30 8 45 27 24.0 49.25 173

1418S81 48 36 8 45 33 30.0 49.25 2011418T81 60 36 8 57 33 30.0 61.25 2461 Does not meet JIC requirements 2 Flat Panel

InnerPanel

Included

Wallm

ou

nt En

closu

res

NEMA Type 12 and 13JIC EGP-1-1967 unless marked1

IEC 529, IP65

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 8: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

➊ Vertical stiffener required on KK, M, MR and LL only.➋ Omit center body stiffener if A is less than 41".➌ Padlocking hasp and staple.➍ Omit 2 middle studs if A is less than 31".➎ Omit body stiffeners if A or B is less than 29".➏ Omit 2 middle studs if B is less than 31".➐ Omit door stiffener if A or B is less than 31" except if AxB is

42"x30", 48"x30" or 72"x30".➑ Omit if A is less than 48".

1418 Series Single Door Enclosures - NEMA 12, 13Continuous Hinge, Clamped Cover

WHEN A= M=

30 7.0036 9.0042 9.8848 11.3860 14.3872 17.38

Section Z-Z

Side View

Top View

Front View

Panel Size Centers ShipPart No. A B C D E F G Wt. lbs

1418B102 16 12 10 13 9 9.5 17.25 30

1418C102 20 16 10 17 13 10.0 21.25 441418D102 20 20 10 17 17 14.0 21.25 52

1418AR102 24 12 10 21 9 9.5 25.25 421418E10 24 20 10 21 17 14.0 25.25 64

1418J10 24 24 10 21 21 18.0 25.25 731418F10 30 20 10 27 17 14.0 31.25 76

1418K10 30 24 10 27 21 18.0 31.25 861418L10 36 24 10 33 21 18.0 37.25 105

1418M10 36 30 10 33 27 24.0 37.25 1241418O101 42 30 10 39 27 24.0 43.25 140

1418P101 42 36 10 39 33 30.0 43.25 1921418R101 48 30 10 45 27 24.0 49.25 162

1418S101 48 36 10 45 33 30.0 49.25 2081418T101 60 36 10 57 33 30.0 61.25 258

1418C122 20 16 12 17 13 10.0 21.25 481418E12 24 20 12 21 17 14.0 25.25 68

1418J12 24 24 12 21 21 18.0 25.25 761418K12 30 24 12 27 21 18.0 31.25 90

1418KK12 30 30 12 27 27 24.0 31.25 1141418L12 36 24 12 33 21 18.0 37.25 108

1418M12 36 30 12 33 27 24.0 37.25 1321418LL121 36 36 12 33 33 30.0 37.25 156

1418O121 42 30 12 39 27 24.0 43.25 1501418P121 42 36 12 39 33 30.0 43.25 198

1418S121 48 36 12 45 33 30.0 49.25 2221418T121 60 36 12 57 33 30.0 61.25 264

1418U121 72 30 12 69 27 24.0 73.25 2721418V12 72 36 12 69 33 30.0 73.25 312

1418E16 24 20 16 21 17 14.0 25.25 741418J16 24 24 16 21 21 18.0 25.25 86

1418K16 30 24 16 27 21 18.0 31.25 1021418M16 36 30 16 33 27 24.0 37.25 140

1418P161 42 36 16 39 33 30.0 43.25 2141418S161 48 36 16 45 33 30.0 49.25 238

1418T161 60 36 16 57 33 30.0 61.25 2901418U161 72 30 16 69 27 24.0 73.25 290

1418K20 30 24 20 27 21 18.0 31.25 1121418M20 36 30 20 33 27 24.0 37.25 152

1418S201 48 36 20 45 33 30.0 49.25 2561418T201 60 36 20 57 33 30.0 61.25 300

1418U201 72 30 20 69 27 24.0 73.25 3081418K24 30 24 24 27 21 18.0 31.25 142

1418U241 72 30 24 69 27 24.0 73.25 3321 Does not meet JIC requirements 2 Flat Panel

➌➍

Wallm

ou

nt En

closu

res

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 9: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

www.hammfg.com

Ind

ustrial En

closu

res

1418 N4 Series Single Door Enclosures - NEMA 12, 4Continuous Hinge, Clamped Cover

InnerPanel

Included

FinishCover and enclosure are finished inrecoatable smooth ANSI/ASA 61gray powder coating.Removable inner panel is finished inwhite powder coating.

AccessoriesAdditional inner panels...see page 384Air conditioners...see page 348-357Blowers...see page 359Breather kits...see page 374Door clamping hardware...see page 378Door stop kits...see page 393Drip shield kits...see page 393Enclosure stabilizers...see page 397Filter fans...see page 360-367Floor stand kits...see page 394Heaters...see page 369-371Lock kit...see page 379Louvered ventilating plates...see page

396Quick release clamp...see page 378Terminal kit assemblies...see page 386Thermostats...see page 374Window kits...see page 391

ApplicationDesigned for use as instrumentenclosures, electric, hydraulic orpneumatic control housings,electrical junction boxes or terminalwiring enclosures.Provides protection whereequipment may be hosed down orotherwise be very wet, or in outdoorapplications for full weatherprotection.

StandardsUL 508 Type 3R,12, 4CSA Type 3R, 12, 4Complies with

NEMA Type 3R, 4, 12 and 13JIC EGP-1-1967 unless marked1

IEC 529, IP66

ConstructionFormed 14 gauge steel bodies anddoors.Smooth, continuously weldedseams without knockouts, cutouts orholes.Door and body stiffeners areprovided in the larger enclosures forextra rigidity.Welded brackets provide forenclosure mounting.Formed lip on door and enclosureexclude flowing liquids andcontaminants.Stainless steel continuous hinge ondoor may be removed by pulling thestainless steel hinge pin.Door is secured with easily operatedstainless steel clamps.Provision for padlocking.Oil resistant gaskets arepermanently secured andmechanically retained.A removable 12 gauge inner panel isincluded.Collar studs are provided formounting inner panels.A bonding stud is provided on thedoor and a grounding stud isprovided in the enclosure.A literature pocket is provided for theinside of the door.

Wallm

ou

nt En

closu

res

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 10: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

www.hammfg.comIn

du

strial Enclo

sures

1418 N4 Series Single Door Enclosures - NEMA 12, 4Continuous Hinge, Clamped Cover

Panel Size Mtg. Centers ShipPart No. A B C D E F G Wt. lbs.

1418N4B62 16 12 6 13 9 9.5 17.25 271418N4G62 16 16 6 13 13 10.0 17.25 341418N4CR62 16 20 6 13 17 14.0 17.25 411418N4C62 20 16 6 17 13 10.0 21.25 401418N4D62 20 20 6 17 17 14.0 21.25 401418N4AR6 24 12 6 21 9 9.5 25.25 411418N4H6 24 16 6 21 13 10.0 25.25 421418N4E6 24 20 6 21 17 14.0 25.25 561418N4J6 24 24 6 21 21 18.0 25.25 651418N4F6 30 20 6 27 17 14.0 31.25 701418N4K6 30 24 6 27 21 18.0 31.25 801418N4L6 36 24 6 33 21 18.0 37.25 911418N4B82 16 12 8 13 9 9.5 17.25 291418N4C82 20 16 8 17 13 10.0 21.25 441418N4D82 20 20 8 17 17 14.0 21.25 511418N4ER8 20 24 8 17 21 18.0 21.25 551418N4E8 24 20 8 21 17 14.0 25.25 601418N4J8 24 24 8 21 21 18.0 25.25 701418N4KR8 24 30 8 21 27 24.0 25.25 741418N4F8 30 20 8 27 17 14.0 31.25 791418N4K8 30 24 8 27 21 18.0 31.25 881418N4KK8 30 30 8 27 27 24.0 31.25 1061418N4L8 36 24 8 33 21 18.0 37.25 1011 Does not meet JIC requirements 2 Flat Panel

Literature pocket supplied loose.Number of door clamps varies to enclosure size.

When A= M=

30 7.0036 9.0042 9.8848 11.3860 14.38Section Z-Z

Section Y-Y

Side ViewFront View

Panel Size Mtg. Centers ShipPart No. A B C D E F G Wt. lbs.

1418N4M8 36 30 8 33 27 24 37.25 1211418N4O81 42 30 8 39 27 24 43.25 1321418N4P81 42 36 8 39 33 30 43.25 1771418N4S81 48 36 8 45 33 30 49.25 2071418N4T81 60 36 8 57 33 30 61.25 2451418N4C102 20 16 10 17 13 10 21.25 471418N4E10 24 20 10 21 17 14 25.25 661418N4K10 30 24 10 27 21 18 31.25 911418N4M10 36 30 10 33 27 24 37.25 1251418N4R101 48 30 10 45 27 24 49.25 1751418N4S101 48 36 10 45 33 30 49.25 1831418N4T101 60 36 10 57 33 30 61.25 2521418N4E12 24 20 12 21 17 14 25.25 711418N4K12 30 24 12 27 21 18 31.25 951418N4L12 36 24 12 33 21 18 37.25 1061418N4M12 36 30 12 33 27 24 37.25 1361418N4P121 42 36 12 39 33 30 43.25 2021418N4S121 48 36 12 45 33 30 49.25 2251418N4K16 30 24 16 27 21 18 31.25 1001418N4M16 36 30 16 33 27 24 37.25 1491418N4S161 48 36 16 45 33 30 49.25 2901418N4T161 60 36 16 57 33 30 61.25 2321 Does not meet JIC requirements 2 Flat Panel

➊ Vertical stiffener required on KK and M only.➋ Omit center body stiffener if A is less

than 41".➌ Padlocking hasp and staple.➍ Omit 2 middle studs if A is less than 31".➎ Omit body stiffeners if A or B is less than 29".➏ Omit 2 middle studs if B is less than 31".➐ Omit door stiffener if A or B is less than

31" except if AxB is 42"x30" or 48"x30".

Wallm

ou

nt En

closu

res

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 11: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

www.hammfg.com

Ind

ustrial En

closu

res

OrderPanel

Separately

1418 Series Single Door Freestanding Enclosures - NEMA 12Single or Dual Access

ApplicationDesigned to house electrical,electronic, hydraulic or pneumaticcontrols with provision for panelmounting or rack mounting ofequipment.Provides a degree of protection fromfalling dirt, dust, oil and water.Available with front access only orboth front and rear access.A variety of inner panels, rackmounting rails and swing out framesare available to provide flexibility inmounting arrangements.

StandardsUL 508 Type 12CSA Type 12Complies with

NEMA Type 12IEC 529, IP65

ConstructionFormed 12 gauge steel.Smooth, continuously weldedseams without knockouts, cutouts orholes.Lifting eyes provide for easyenclosure handling.Doors are supported with heavygauge continuous hinges.Doors are secured with a three pointlatch and operated with a keylocking automotive type handle.Latch rods are equipped with rollersfor easier door closing.Oil resistant gaskets arepermanently secured andmechanically retained.Mounting channels are welded onthe inside of the enclosure formounting of optional inner panels orrack equipment rails.A grounding stud is provided in theenclosure and a bonding stud isprovided on the door.A literature pocket is provided for theinside of the door (Two pockets areprovided for dual access units).

FinishCover and enclosure are finished inrecoatable smooth ANSI/ASA 61 graypowder coating on the outside, withwhite powder coating on the inside.Optional inner panels, rails, framesand supports are finished in whitepowder coating.

AccessoriesAir conditioners...see page 348-357Blowers...see page 359Breather kits...see page 374Door stop kits...see page 393Drip shield kits...see page 393Filter fans...see page 360-367Heaters...see page 369-371Inner panels...see page 64Light kit...see page 393Louvered ventilating plates...see page

396Panel rails...see page 65Swing frames...see page 65Thermostats...see page 374Window kits...see page 391

Freestand

ing

Enclo

sures

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 12: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

www.hammfg.comIn

du

strial Enclo

sures

Note: 4 eyebolts are provided for 30.06" and 36.06" deep enclosures(both dual and single access)

Single Access-Front View

Dual Access-Front View

Dual Access-Side View

Single Access

Optional ShipFull Wt.

Part No. A B C F G Panel1 lbs.

1418TW18 60.06 24.06 18.06 32.03 23.13 60TWFW 210

1418W18 72.06 24.06 18.06 38.03 29.13 72WFW 2461418X18 72.06 30.06 18.06 38.03 29.13 72XFW 285

1418Y18 72.06 36.06 18.06 38.03 29.13 72YFW 3251418YW20 90.06 24.06 20.06 47.03 38.13 90YWFW 313

1418YY20 90.06 36.06 20.06 47.03 38.13 90YFW 4061418TY24 60.06 36.06 24.06 32.03 23.13 60TYFW 325

1418W24 72.06 24.06 24.06 38.03 29.13 72WFW 3001418X24 72.06 30.06 24.06 38.03 29.13 72XFW 335

1418Y24 72.06 36.06 24.06 38.03 29.13 72YFW 3701418YY24 90.06 36.06 24.06 47.03 38.13 90YFW 440

1418W30 72.06 24.06 30.06 38.03 29.13 72WFW 3551418Y30 72.06 36.06 30.06 38.03 29.13 72YFW 420

1418W36 72.06 24.06 36.06 38.03 29.13 72WFW 4001418Y36 72.06 36.06 36.06 38.03 29.13 72YFW 465

1418YY36 90.06 36.06 36.06 47.03 38.13 90YFW 5251 Refers to Optional Full Height/Full Width Panels. Depth Panels & Half

Height Width panels are also available...see page 64.

Dual Access

Optional ShipFull Wt.

Part No. A B C F G Panel1 lbs.

1418WD24 72.06 24.06 24.06 38.03 29.13 72WFW 325

1418XD24 72.06 30.06 24.06 38.03 29.13 72XFW 4241418YD24 72.06 36.06 24.06 38.03 29.13 72YFW 474

1418YYD24 90.06 36.06 24.06 47.03 38.13 90YFW 5401418WD30 72.06 24.06 30.06 38.03 29.13 72WFW 375

1418WD36 72.06 24.06 36.06 38.03 29.13 72WFW 4251418YD36 72.06 36.06 36.06 38.03 29.13 72YFW 495

1418YYD36 90.06 36.06 36.06 47.03 38.13 90YFW 5551 Refers to Optional Full Height/Full Width Panels. Depth Panels & HalfHeight Width panels are also available...see page 64.

Maximum Useable DepthSingle Access onlyFrom inside surface of front door to front face of Full Width PanelInner Panel in Full Back Position

Single Access-Side View

Enclosure MaximumDepth (In.) Usable Depth

18.06 17.8020.06 19.8024.06 23.8030.06 29.8036.06 35.80

Freestand

ing

Enclo

sures

1418 Series Single Door Freestanding Enclosures - NEMA 12Single or Dual Access

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 13: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

www.hammfg.com

Ind

ustrial En

closu

res

OrderPanel

Separately

FinishCover and enclosure are finished inrecoatable smooth ANSI/ASA 61 graypowder coating on the outside, withwhite powder coating on the inside.Optional inner panels, rails, framesand supports are finished in whitepowder coating.

AccessoriesAir conditioners...see page 348-357Blowers...see page 359Breather kits...see page 374Center panel support...see page 64Door stop kits...see page 393Drip shield kits...see page 393Filter fans...see page 360-367Heaters...see page 369-371Inner panels...see page 64Light kit...see page 393Louvered ventilating plates...see page 396Panel rails...see page 65Swing frames...see page 64Thermostats...see page 374Window kits...see page 391

ConstructionFormed 12 gauge steel (10 gaugeon back of single accessenclosures).Smooth, continuously welded seamswithout knockouts, cutouts or holes.Stiffeners on the rear of theenclosure provide rigidity.Lifting eyes provide for easyenclosure handling.Doors are supported with heavygauge continuous hinges.Doors are secured with a three pointlatch and operated with a keylocking automotive type handle.Latch rods are equipped with rollersfor easier door closing.Oil resistant gaskets arepermanently secured andmechanically retained.Mounting channels are welded onthe inside of the enclosure formounting of optional inner panels orrack equipment rails.A bonding stud is provided on thedoor and a grounding stud isprovided in the enclosure for eachdoor.A literature pocket is provided for theinside of the door (Two pockets areprovided for dual access units).

ApplicationDesigned to house electrical,electronic, hydraulic or pneumaticcontrols with provision for panelmounting or rack mounting ofequipment.Provides a degree of protection fromfalling dirt, dust, oil and water.Available with front access only orboth front and rear access.A variety of inner panels, rackmounting angles and swing framesare available to provide flexibility inequipment mounting.

StandardsUL 508 Type 12CSA Type 12Complies with

NEMA Type 12IEC 529, IP65

1418 Series Two Door Freestanding Enclosures - NEMA 12Single or Dual Access

Freestand

ing

Enclo

sures

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 14: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

www.hammfg.comIn

du

strial Enclo

sures

Note: 4 eyebolts are provided for 36.06" deep enclosures (bothdual and single access)

Single Access

Optional ShipFull Wt.

Part No. A B C F G Panel1 lbs.

1418AW18 60.06 48.06 18.06 32.03 23.13 60AWFW 550

1418ZW18 72.06 48.06 18.06 38.03 29.13 72ZWFW 5751418ZX18 72.06 60.06 18.06 38.03 29.13 72ZXFW 625

1418ZY18 72.06 72.06 18.06 38.03 29.13 72ZYFW 7001418BW20 90.06 48.06 20.06 47.03 38.13 90BWFW 650

1418BY20 90.06 72.06 20.06 47.03 38.13 90BYFW 9001418BY24 90.06 72.06 24.06 47.03 38.13 90BYFW 950

1418ZW24 72.06 48.06 24.06 38.03 29.13 72ZWFW 6001418ZX24 72.06 60.06 24.06 38.03 29.13 72ZXFW 650

1418ZY24 72.06 72.06 24.06 38.03 29.13 72ZYFW 7401418ZX36 72.06 60.06 36.06 38.03 29.13 72ZXFW 850

1418BY36 90.06 72.06 36.06 47.03 38.13 90BYFW 11001 Refers to Optional Full Height/Full Width Panels. Depth Panels & HalfHeight Width panels are also available...see page 64.

Dual Access

Optional ShipFull Wt.

Part No. A B C F G Panel1 lbs.

1418ZWD2472.06 48.06 24.06 38.03 29.13 72ZWFW 625

1418ZXD24 72.06 60.06 24.06 38.03 29.13 72ZXFW 6501418ZYD24 72.06 72.06 24.06 38.03 29.13 72ZYFW 725

1418BYD24 90.06 72.06 24.06 47.03 38.13 90BYFW 10001418ZXD36 72.06 60.06 36.06 38.03 29.13 72ZXFW 9001 Refers to Optional Full Height/Full Width Panels. Depth Panels & HalfHeight Width panels are also available...see page 64.

Dual Access-Side View

Single Access-Side ViewSingle or Dual Access - Front View

1418 Series Two Door Freestanding Enclosures - NEMA 12Single or Dual Access

Freestand

ing

Enclo

sures

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 15: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

www.hammfg.com

Ind

ustrial En

closu

res

OrderPanel

Separately

1418 N4 Series Freestanding Enclosures - NEMA 4, 12Single Door

ApplicationDesigned to house electrical,electronic, hydraulic or pneumaticcontrols with provision for panelmounting or rack mounting ofequipment.Provides protection whereequipment may be hosed down orotherwise be very wet, or in specificapplications where corrosion is aserious problem.A variety of inner panels, rackmounting rails and swing out framesare available to provide flexibility inmounting arrangements.

StandardsUL 508 Type 3R, 4 and 12CSA Type 3R, 4 and 12Complies with

NEMA Type 3R, 4, 12 and 13IEC 529, IP66

ConstructionFormed 12 gauge steel.Smooth, continuously weldedseams without knockouts, cutouts orholes.Lifting eyes provide for easyenclosure handling.Doors are supported with heavygauge continuous hinges.Doors are secured with heavy dutystainless steel clamps.Oil resistant gaskets arepermanently secured andmechanically retained.Mounting channels are welded onthe inside of the enclosure formounting of optional inner panels orrack equipment rails.A grounding stud is provided in theenclosure and a bonding stud isprovided on the door.

FinishCover and enclosure are finished inrecoatable smooth ANSI/ASA 61 graypowder coating on the outside, withwhite powder coating on the inside.Optional inner panels are finished inwhite powder coating.

AccessoriesAir conditioners...see page 348-357Breather kits...see page 374Door stop kits...see page 393Drip shield kits...see page 393Filter fans...see page 360-367Heaters...see page 369-371Light kit...see page 393Panel rails...see page 65Inner panels...see page 64Swing frames...see page 65Thermostats...see page 3714Window kits...see page 391

Freestand

ing

Enclo

sures

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Page 16: 1418J Series - NEMA 12 - files.clrwtr.com · 1418N4SSE6 24 20 6 21 17 14.0 25.25 61 ... NEMA 4 Continuous Hinge, Clamped Cover Inner Panel Included Application Designed for use as

www.hammfg.comIn

du

strial Enclo

sures

1418 N4 Series Freestanding Enclosures - NEMA 4, 12Single Door

Optional Ship Wt.Part No. A B C Full Panel1 lbs.

1418N4W18 72.06 25.06 18.06 72WFW 290

1418N4X24 72.06 31.06 24.06 72XFW 2501418N4Y24 72.06 37.06 24.06 72YFW 3901 Refers to Optional Full Height/Full Width Panels. Depth Panels & Half Height Width panels are also

available...see page 64.

Lip Detail TopHorizontal

Vertical CrossSection

Strut DetailRight Side

Front View

Top View

Cross SectionSide View

Freestand

ing

Enclo

sures

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]