  • dip dtstp:dip=all;(dont give a,b,c)

    To find list of sites whose DIP is in ABL state dtstp:dip=all,state=abl;

    dtstp:digital path state print

    To check quality of dip dtqup:dip=dip name;

    dtqup:digital path quality print

    To refresh errors in DIP dtqsr:dip=dip name,unacc,degr,sf;

    dtqsr:digital path quality supervision reset

    unacc:All parameters of unacceptable performance level is reset(ES,SES,DM)

    DEGR:all parameters of degraded performance level is reset

    To see status of all DIP dtqup:dip=all;

    To change the name of DIP dtpnc:dip=dip name,new dip=new dip name;

    dtpnc:digital path name change

    cell=cell designation which can have maximum of 7 characters

    To deblock a particular DIP dtble:dip=dip name;

    dtble:digital path transmission functioning blocking end

    To find cell status rlcrp:cell=all;

    rlcrp:radio controlled cell resources print

    To find if a particular cell has a got TS blockage SDCCH+CBCH=X

    Divide X/8 and ADD this to BCCH and NOOFTCH if this is equal to 32(For 4 tru)

    then there is no blockage or else there is a blockage

    Why 32:Because in 1 TRU there are 8 TS

    to find external alarms allip:alcat=ext;

    to find level 1& 2 alarms allip:acl=a1;

    allip:acl=a2;

    allip:alarm functions alarm list print

    alcat:alarm category

    to find TG Value rxtcp:moty=rxotg,cell=name;

    rxtcp:radio x-ceiver administration TG to channel group

    deblocking the tru

  • To block deblock CF rxbli:mo=rxocf-TG Value;

    To block a particular TS rxbli:mo=rxots-53-1-1;

    To deblock a particular TS rxble:mo=rxots-53-1-1;

    To find CF fault codes rxmfp:mo=rxocf-502,faulty;

    To find all fault codes CF and TRX faults rxmfp:mo=rxotg-23,subord,faulty;

    To find all the CF Fault affected sites rxasp:moty=rxocf ;

    rxasp:radio x ceiver administration managed object alarm status print

    To find if a particular TRU is in local mode rxasp:mo=rxotrx-trx value;

    rxasp:radio x-ceiver administration managed object alarm situation print

    To find all fault codes CF and TRX faults rxmfp:mo=rxotg-23,subord,faulty;

    To hault or activate a paricular cell rlstc:cell=cell name,state=halted,active;

    rlstc:radio control cell state change

    To find the list of devices rxapp:mo=rxotg-TG Value;

    To find MO status rxmsp:mo=rxocf-109,subord;

    To find status of various TRX in a TG rxmsp:mo=rxotrx-6-7,subord;

    if the status of TRU are unconfig and site is not halted check may be TRU are wrongly defined

    and check the tx power of transmitter

    To find property of TRX rxmop:mo=RXOTrx-406-1;

    To find software version of a site rxmop:mo=rxotg-TG Value;

    see last 2 digits of SWVERDLD and SWVERACT to know softaware version

    To get list of devices attached to TG Value rxapp:mo=rxotg-TG Value;

    rxapp:radio x-ceiver administration abis path status print

    To find cabinet type rxmfp:mo=rxocf-TG Value;

    To find KLM and vc-12 value tpcop:sdip=0etm2;

    Procedure to find a site is independent radep:dev=RBLT2-2239(From this command find the value of SNTINL

    RBLT2 is one device of slave side

    radep:dev=RBLT2-2239(From this command find the value of SNTINL

    ntcop:snt=etm2-3;

    Fromt this command the site which has got the same value of SNTINL is the master

    To find out TEI value of a site and signalling rxmop:mo=rxocf-TG Value;

    To find the power in a particular TX rxmop:mo=rxotx-TX Value of a site;

    To find site id through TG Value rxmop:mo=rxotx-402-2;

    rxasp:mo=rxotrx-TEI Value;

    To find log of a particular site step1:type F8 to create a log file

    step2:aploc;

    alogfind -a starttime -e startdate(year/month/day) -b closetime -g closedate

    close log file

  • To test a particular managed object rxtei:mo=mo value(rxotrx,rxorx,rxorx,rxots)

    rxtei:radio x-ceiver administration test of mo initiate

    rxtee:mo=mo value(rxotrx,rxorx,rxorx,rxots)

    To find overall status of a site rxcdp:mo=rxotg-TG Value;

    rxcdp:radio x ceiver administaration m/o configuration data

    To find information about m/o device rxmdp:mo=

    THIS COMMAND IS VALID FOR CF,DP,TRXC,TSrxmdp:mo=rxocf-125;

    To make UNCONFIG TS CONFIG provided the rxbli:mo=rxotg-16,subord,force;

    cell is not halted rxese:mo=rxotg-16,subord;

    To load a paricular site rxesi:mo=rxotg-16,subord;

    both things can be done at the same time rxble:mo=rxotg-16,subord;

    To change tx power of trx rxmoc:mo=rxotrx-TEI VALUE,mpwr=power;

    rxmoc:radio x-ceiver administration m/o object data change

    To define a new DIP NTCOP:snt=etm2-3;

    etm value in which that dip needs to be created

    ntcop:switching network terminal connection data,print

    tpcop:sdip=0etm2;

    TPCOP:transmission function synchronous digital path connection data print

    dtdii:dip=dipname,snt=etm2-3,dipp=x;

    x-value corresponding to vc-12 for that particular KLM

    tpble:sdip=3etm2,lp=vc12-8;

    tpble:transmission func synchronous digital path,blocking end

    sdip:synchronous digital path

    lp:lower order path

    dtble:dip=dip name;

    dtble:digital path func blocking end

    To remove TS having LOOP TEST FAILED rxbli:mo=rxots-53-1-1;

    rxble:mo=rxots-53-1-1;

    rlncp:radio controlled cell neighbour to cell print

    To find status of link for aparticular BSC c7ltp:ls=all;

    ls:link set

    To find out put pwer of a particular cell rlcpp:cell=cell name;

    rlcpp:radio controlled cell configuration data print

  • mstxpwr:bspwrb Base Station (BS) output power in dBm, for Broadcast Control Channel (BCCH)

    Radio Frequency (RF) channel number.

    The current Base Transceiver Station (BTS) version may have specific parameter restrictions.

    See "BTS parameter limitations" in OPERATION AND MAINTENANCE MANUAL for current BTS

    version.

    This parameter is not valid for external cell.

    bspwrt Base Station output power in dBm, for the non-BCCH RF channel numbers.

    cell Cell designation

    mstxpwr Maximum transmit power for the Mobile Station (MS) on connection.

    sctype Subcell type.

    UL

    Underlaid subcell

    OL

    Overlaid subcell.

    To print DTX downlink data for a cell rlcxp:cell=cell name;

    rlcxp:radio control cell config. DTX dowlink print

    dtxd Discontinues downlink transmission.

    ON Discontinues downlink

    transmission is enabled

    in the BSC for the cell.

    OFF Discontinues downlink

    transmission is disabled

    in the BSC for the cell.

    To deblock a DIP whose SDIP Layer is manually blockeddtdip:dip=dip name;

    note etm value and dipport(dipp value)

    tpble:sdip=4etm2,lp=vc12-dippvalue

    dtble:dip=dip name;

    dtstp:dip=dip name;

    TRX status rxcdp:mo=rxotg-tgvalue

  • dfel5186

    qwerty@123

  • if the status of TRU are unconfig and site is not halted check may be TRU are wrongly defined

  • 12

    3

    4

    5

  • TEI Terminal end point identifier

  • To delete a device

    to check the state of the device

    to check etm no

    To check TG value

  • blodi:dev=RTLTT2-4608&&-4639;

    stdep:dev=RTLTT2-4608&&-4639;

    dtdip:dip=dip name;

    ntcop:snt=etm4-2;

    rxmdp:dev= RBLT2-7809,moty=rxots;