    LaboratoryMonitoring

    Systems

    Contronics Limited

    Greenfield Farm Estate

    Congleton Cheshire

    CW12 4TU

    Phone

    +44 (0) 1260 298 383

    Fax

    +44 (0) 1260 298 387

    [email protected]

    www.contronics.co.uk

    tron csinoc

    The Control Program can

    also display and print

    composite trend graphs

    showing all the sensors

    connected to any piece

    of equipment for any

    timeframe . . .

    The Control Program

    can sort the

    complete audit trail

    back to system

    switch-on by

    timeframe, event

    type, equipment,

    sensor and

    department . . .

    Alerter

    The Alerter is a pop-up application. It can be installed on

    any PC with access to the network. Users can configure

    the program to respond

    only to alarms from

    relevant departments.

    Alerter provides real

    time audible and visual

    indication of alarm

    conditions. The pop-updisplay mirrors the alarm

    information displayed on

    an InfoPoint.

    A remote user can accept alarms using the Control

    Program. The audit trail is maintained whether the alarm

    is accepted using the InfoPoint or the Control Program.

    Working together

    We work closely with our customers from the initial user

    requirement specification through to system acceptance.

    We can temperature map your equipment and provide

    documented justification for sensor positions.

    Our engineers will install, commission, calibrate and

    validate your system and train your staff. We will work

    with you to generate the qualification protocols you needto satisfy your regulatory requirements.

    Support you can rely on

    A one year, on-site, parts and labour warranty

    demonstrates our confidence in our systems.

    On-going maintenance agreements preserve your

    investment in Contronics systems. We look after

    preventative maintenance and scheduled annual

    calibration, validation and mapping and prepare a

    comprehensive documentation pack ready for your

    regulatory inspection.

    Specification

    Prolog Lite (with integral InfoPoint)

    Network connection Ethernet

    System capacity 25/50/100 sensors

    Channel configuration (max) 4 sensors + 4 contact inputs

    Database MySQL

    Audit trail + data log Back to commissioning

    Channel titles + alarm messages User configurable

    Alarm management Via InfoPoint or Control Program

    Off site alarms Email to on-call staff

    Mobile alert to smartphone

    UPS runtime 15 minutes

    Dimensions 385 x 375 x 75 (WxHxD)

    InfoPoint

    Network connection Ethernet

    Display 17 colour LCD

    1024 x 768 SVGA resolution

    User interface Touch screen navigation

    with on-screen keyboard

    UPS runtime 15 minutes

    Dimensions 385 x 375 x 75 (WxHxD)

    DataNode (specification for 16 input DataNode)

    Network connection Ethernet

    Inputs 16 analogue

    16 contact

    4 serial

    Outputs 4 changeover relays

    Sensor types Temperature

    Relative humidity

    Oxygen depletionCarbon dioxide level

    Differential pressure

    Particle count

    Voltage/current input

    Door contact

    Panic button

    Motion detector

    Measurement reso lution 0.1C or 0.1% ful l sca le

    Measurement accuracy 0.2C or 0.2% ful l sca le

    Log interval 1 to 99 minutes

    Stored data 1 week at 1 min log interval

    Alarm levels 4

    Alarm delays 0 to 99 minutes

    UPS runtime 6 hours

    Dimensions 384 x 470 x 58mm (WxHxD)

    9100QB0904

  • 7/29/2019 1349445838.8964_9100QB0904 Prolog Lite (web version).pdf

    2/2

    tron csinoc

    Prolog Lite

    Prolog Lite is the latest addition to our world-class range of

    environmental monitoring systems. The system is 21CFR11

    Part 11 and GAMP compliant and will satisfy MHRA

    requirements. It is a multi-user system with the capacity to

    monitor up to 100 points distributed over multiple sites. It

    monitors a complete facility whilst maintaining departmental

    separation and responsibility. Prolog Lite combines the server

    and InfoPoint in a single, wall-mounted unit.

    The server uses an industry standard MySQL database. It

    stores the system configuration information and accumulates

    measurements from DataNodes. It also maintains a secure

    audit trail of alarms, alarm acceptances, settings changes and

    all system events and actions taken. Prolog Lite makes

    scheduled automatic database backups to a nominated server

    on the network.

    The system is highly resilient. Logged data is duplicated in

    the database and in DataNode. If the network connection to

    DataNode is interrupted, missing database information will be

    automatically retrieved when the network connection is

    restored.

    The system generates four alarms per sensor; upper and lower

    warning levels and upper and lower alarm levels.

    Prolog Lite will send email containing detailed alarm

    information to predefined addresses: including smartphones.

    Separate addresses can be defined for each department.

    Departmental responsibility is achieved by configuringInfoPoint displays to respond only to alarms for specific

    departments.

    As shown in the diagram above, Prolog Lite is connected by a

    standard Ethernet network to distributed DataNodes which

    collect and store data from local sensors. Local InfoPoints

    display alarms and information only from equipment for

    which the department is responsible.

    ProLog Lite software is being continuously developed to

    reflect the changing needs of users and to ensure that the

    system complies with current legislation and practice.

    Software updates are offered free of charge during warranty

    and subsequent maintenance agreements.

    InfoPoint

    The 17, wall-mounted, colour LCD touch-screen display and

    intuitive user interface mean that InfoPoint is simple to use,

    easy to understand and minimises training.

    InfoPoint displays alarm conditions, current sensor values and

    settings, audit trail information and trend graphs.

    Alarms can be accepted, channels can be inhibited and

    temporary disables initiated (eg for defrost). All the

    frequently used system operation and maintenance functions

    are included.

    InfoPoint uses an index card metaphor to simplify navigation.

    Touching the tab at the top of the screen changes the display

    mode.

    When an alarm occurs, InfoPoint generates an audible and

    visual alarm, jumps to the alarm tab and displays the alarm

    information and advisory text . . .

    Username and password are necessary to accept alarms and a

    user comment is required for the audit trail. These are

    entered using the on-screen keyboard . . .

    Sensor data is displayed graphically . . .

    An image can be

    inserted on the status

    page to provide more

    information . . .

    InfoPoints can be

    distributed

    throughout a facility

    as required and alarm notifications can be transferred to a

    different InfoPoint when a department is not staffed.

    InfoPoints UPS ensures operation is maintained during

    changeover to emergency supply.

    DataNode

    DataNode accepts up to 16 analogue inputs, 16 contact

    inputs and 4 serial inputs. In addition, 8/4/2 analogue input

    versions are available to minimise system cost for smaller

    applications. The minimum logging interval is 1 minute.

    At this setting, DataNode stores 1 week of local data.

    DataNode makes continuous analogue sensor measurements

    at 1-second intervals and stores the worst excursion during

    the logging interval in the database. It accepts a range of

    inputs as shown in the specification on the back page.

    The serial inputs interface with particle counters and other

    intelligent sensors.

    DataNode has 4 relay outputs. These can be configured to

    change state for any combination of alarms and used, for

    example, for local alarm indication.

    Each channel (or piece of equipment) can be configured to

    include up to 4 analogue or serial inputs and 4 contact inputs.

    A UPS is installed to enable DataNode to continue logging if

    the mains supply fails.

    Control ProgramThe Control Program is used to configure and control a

    ProLog system. The Control Program is a web application;

    this means that any PC on the network can access this

    program using a familiar web browser.

    The system manager specifies the users who have access to

    the system and attaches users to departments.

    Usernames, passwords and the required level of access

    permissions are allocated to users so that they can configure

    and maintain the system, accept alarms and alter settings

    within their designated departments.

    Details of alarm acceptances, settings changes and any other

    interventions are recorded in a secure audit trail along with

    users name and comments.

    A channel is configured for each piece of equipment attached

    to the system. Sensors are assigned to a channel and upperand lower warning and alarm levels are set. The channel

    names, sensor names, alarm messages and optional channel

    and sensor advisory text are entered. The equipment supplier,

    part number and serial number are also recorded . . .

    Central action point

    Prolog lite

    Central action point Remote site without local action pointR

    emo te s it e w it ho ut local act io n p oint Major d ep ar tmen t w it h local act io n p ointM

    ajor department with local action point Smaller department without local action pointS

    maller department without local action point

    Email

    Smartphone

    roog ie

    Motion detection

    Panic button

    Door contact

    Current input

    oltage input

    V

    Particle count

    ferential pressure

    Dif

    Carbon dioxide level

    Oxygen depletion

    Relative humidity

    emperature

    T

    InfoPoint

    Motion detection

    Panic button

    Door contact

    Current input

    V

    Particle count

    Dif

    Carbon dioxide level

    Oxygen depletion

    Relative humidity

    T

    Motion detection

    Panic button

    Door contact

    Current input

    oltage inputV

    P

    article count

    ferential pressureDif

    Carbon dioxide level

    Oxygen depletion

    Relative humidity

    mperature

    Motion detection

    Panic button

    Door contact

    Current input

    oltage input

    V

    Particle count

    ferential pressure

    Dif

    Carbon dioxide level

    Oxygen depletion

    Relative humidity

    emperature

    T

    Email

    Alerter + Control Program

    required access permissions running

    Remote user with passwords and

    Alerter + Control Program

    required access permissions running

    Remote user with passwords and

    Internet

    Alerter + Control Program

    Networked PC running

    Ethernet network

    Alerter + Control Program

    Networked PC running

    InfoPoint

    Alerter + Control Program

    Networked PC running

    Alerter + Control Program

    Networked PC running

    Alerter + Control Program

    Networked PC running

    LaboratoryMonitoringSystems