12TH FLOOR CALL CENTER - Wise Construction · a-000 general notes, abbreviations, legends a-130...
Transcript of 12TH FLOOR CALL CENTER - Wise Construction · a-000 general notes, abbreviations, legends a-130...
SCOPE OF WORK 12TH FLOOR BUILDING 2
DRAWING LIST
A-000 GENERAL NOTES, ABBREVIATIONS, LEGENDS
A-130 PHASING PLAN
A-140 DEMOLITION PLAN NORTH, GENERAL NOTES, KEYS, LEGENDS
A-141 DEMOLITION PLAN SOUTH
A-150 FLOOR PLAN NORTH, GENERAL NOTES, KEYS, LEGEND
A-151 FLOOR PLAN SOUTH
A-170 REFLECTED CEILING PLAN NORTH, GENERAL NOTES, KEYS, LEGENDS
A-171 REFLECTED CEILING PLAN SOUTH
A-180 FFE PLAN NORTH
A-181 FFE PLAN SOUTH & SCHEDULES
A-210 INTERIOR ELEVATIONS
A-710 TYPICAL PARTITION DETAILS
A-720 TYPICAL REFLECTED CEILING DETAILS
A-760 TYPICAL DOOR FRAME TYPES & DETAILS
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661 www.isgenuity.com
Architect
Project Number:
Date Issued:
NOT FOR CONSTRUCTION
12TH FLOOR CALL CENTER
179-18-00
04/08/19
VERTEX PHARMACEUTICALS
12TH FLOOR CALL CENTER
50 Northern AveBoston, MA 02110
ISSUED FOR BID
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
MEP/FP Engineer
FP0.00 FIRE PROTECTION LEGEND, NOTES & DETAILSFP1.12A FIRE PROTECTION 12TH FLOOR NORTH PLANFP1.12B FIRE PROTECTION 12TH FLOOR SOUTH PLAN
M0.00 HVAC LEGEND & GENERAL NOTESM0.01 HVAC SCHEDULES & DETAILSM0.02 HVAC SPECIFICATIONM1.12 HVAC 12TH FLOOR DUCTWORK PLAN
E0.00 ELECTRICAL LEGEND AND NOTESE0.01 ELECTRICAL SCHEDULES AND RISER DIAGRAME0.02 ELECTRICAL DETAILSE0.03 ELECTRICAL SPECIFICATIONSE1.12 ELECTRICAL 12TH FLOOR LIGHTING PLANSE2.12 ELECTRICAL 12TH FLOOR POWER PLANS
FA0.00 FIRE ALARM LEGEND, NOTES & DETAILSFA1.12A FIRE ALARM 12TH FLOOR NORTH PLANFA1.12B FIRE ALARM 12TH FLOOR SOUTH PLAN
Issuance Schedule
Number Date Description
& ANDL ANGLE@ AT
CENTERLINEØ DIAMETER# POUNDA/E ARCHITECT / ENGINEERAB ANCHOR BOLTACBL ACCESSIBLE (ADA COMPLIANT)ACOUS ACOUSTICALACP ACOUSTICAL CEILING PANELAD ACCESS DOORADA THE AMERICANS WITH DISABILITIES ACTADBL ADAPTABLE (ADA COMPLIANT)ADDL ADDITIONALADH ADHESIVEADJ ADJUSTABLEADJC ADJACENTAF ACCESS FLOORAFF ABOVE FINISHED FLOORAFI AIR FLOW INDICATORAGGR AGGREGATEAL ALUMINUMALT ALTERNATEANOD ANODIZEDAP ACCESS PANELARCH ARCHITECTASC ABOVE SUSPENDED CEILINGASPH ASPHALTAVAF AUDIO/VISUAL ALARM
BD BOARDBLDG BUILDINGBLKG BLOCKINGBM BEAMBOT BOTTOMBUR BUILT-UP ROOFING
CA CARD ACCESSCAB CABINETCB CASING BEADCEM CEMENTCEMTS CEMENTITIOUSCER CERAMICCG CORNER GUARDCGE CORNER END GUARDCHAN CHANNELCHBD CHALKBOARDCHFR CHAMFERCJ CONSTRUCTION JOINTCL CENTER LINECLG CEILINGCLJ CONTROL JOINTCLO CLOSETCLR CLEARCLRM CLASSROOMCMPST COMPOSITECMU CONCRETE MASONRY UNITCNTR COUNTERCO CASED OPENINGCOL COLUMNCOMP COMPUTERCONC CONCRETECONN CONNECTIONCONSTR CONSTRUCTIONCONT CONTINUOUSCONTR CONTRACTORCORR CORRIDORCPRS COMPRESSIBLE OR COMPRESSIONCR CHAIR RAILCRS COLD ROLLED STEELCS CAST STONECSK COUNTERSUNKCSMT CASEMENTCSWK CASEWORKCYL CYLINDER
DBL DOUBLEDEMO DEMOLITIONDEPT DEPARTMENTDET DETAILDF DRINKING FOUNTAINDG DECORATIVE GLASSDIA DIAMETERDIM DIMENSIONDISP DISPENSERDIV DIVISIONDMBD DRY MARKER BOARDDMPF DAMPPROOFINGDN DOWNDO DITTODOP DOOR OPENINGDPG DECORATIVE PLASTIC GLAZINGDS DOWNSPOUTDSP DRY STANDPIPEDST DOOR STOPDWG DRAWINGDWR DRAWER
E EASTEA EACHEIFS EXTERIOR INSULATION & FINISH SYSTEMEL ELEVATIONELAST ELASTOMERICELEC ELECTRICELEV ELEVATOREMER EMERGENCYENCL ENCLOSUREENGR ENGINEERENTR ENTRANCEEO EMERGENCY POWEREP ELECTRICAL PANELEPDM ETHYLENE PROPYLENE DIENE MONOMEREPRF EXPLOSION PROOFEQ EQUALEQUIP EQUIPMENTESCAL ESCALATOREW EACH WAYEWC ELECTRIC WATER COOLEREXC EXCAVATEEXH EXHAUSTEXP EXPANSIONEXIST EXISTINGEXT EXTERIOR
F/F FACE TO FACEF/T/UC FLOOR / TABLE / UNDERCOUNTERFA FIRE ALARMFACP FIRE ALARM CONTROL PANELFB FLAT BARFCO FLOOR CLEAN OUTFD FLOOR DRAINFDC FIRE DEPARTMENT CONNECTIONFDN FOUNDATIONFEC FIRE EXTINGUISHER CABINETFE FIRE EXTINGUISHERFGL FIBERGLASSFHC FIRE HOSE CABINETFHP FULL HEIGHT PARTITIONFH FULL HEIGHTFIN FINISHFL FLASHINGFLR FLOOR OR FLOORINGFLUOR FLUORESCENT
FOC FACE OF CONCRETEFOF FACE OF FINISHFOM FACE OF MASONRYFOS FACE OF STUDFPRF FIREPROOFINGFS FULL SIZEFSH FIRE SPRINKLER HEADFSTP FIRESTOPPINGFT FOOT OR FEETFTG FOOTINGFURN FURNITUREFURR FURRINGFUT FUTURE
G GASGA GAGEGALV GALVANIZEDGB GRAB BARGEN GENERATORGFRC GLASS FIBER REINFORCED CONCRETEGFRG GLASS FIBER REINFORCED GYPSUMGL GLASSGLMU GLASS MASONRY UNITGMMU GLASS MESH MORTAR UNITGND GROUNDGR GRADEGRL GRILLEGRTG GRATINGGSKT GASKETGT GROUTGVL GRAVELGWB GYPSUM WALL BOARDGYP GYPSUM
HB HOSE BIBBHC HOLLOW COREHDBD HARDBOARDHDWD HARDWOODHDWE HARDWAREHGR HANGERHGT HEIGHTHM HOLLOW METALHMD HOLLOW METAL DOORHNDRL HANDRAILHO HOLD OPENHORIZ HORIZONTALHPT HIGH POINTHR HOURHSAFD HORIZONTAL SLIDING ACCORDION FIRE DOORHVAC HEATING, VENTILATION, AIR CONDITIONINGHYDR HYDRAULIC
ID INSIDE DIAMETERIF INSIDE FACEIN INCH OR INCHESINSUL INSULATIONINTR INTERIORIWH INSTANTANEOUS WATER HEATER
JAN JANITORJST JOISTJT JOINT
KIT KITCHENKO KNOCKOUTKOP KNOCKOUT PANELKPL KICK PLATE
L LEFTLAB LABORATORYLAD LADDERLAM LAMINATIONLAV LAVATORYLB POUNDLBL LABELLF LINEAR FOOTLG LENGTHLG LENGTHLH LEFT HANDLHR LEFT HAND REVERSELIB LIBRARYLIN LINEARLKR LOCKERLLH LONG LEG HORIZONALLLV LONG LEG VERTICALLNTL LINTELLONG LONGITUDINALLP LIGHTPROOFLPT LOW POINTLT LIGHTLTWT LIGHTWEIGHTLTG LIGHTINGLVR LEVER OR LOUVER
MACH MACHINEMAINT MAINTENANCEMAS MASONRYMATL MATERIALMAX MAXIMUMMECH MECHANICALMED MEDIUMMEMB MEMBRANEMET METALMEZZ MEZZANINEMFG MANUFACTURERMH MANHOLEMIN MINIMUMMIR MIRRORMISC MISCELLANEOUSML METAL LATHMLDG MOLDINGMLWK MILLWORKMO MASONRY OPENINGMTD MOUNTEDMTR MORTARMULL MULLIONMVBL MOVABLE
N NORTHNA NOT APPLICABLENAT NATURALNIC NOT IN CONTRACTNO NUMBERNOM NOMINALNTS NOT TO SCALE
OA OVERALLOC ON CENTEROD OUTSIDE DIAMETEROF OUTSIDE FACEOF/CI OWNER FURNISHED/CONTRACTOR INSTALLEDOFF OFFICEOPNG OPENINGOPP OPPOSITEOT ELECTRICAL OUTLETOXY OXYGEN
PB PANIC BARPERF PERFORATEDPERIM PERIMETERPERP PERPENDICULARPGBD PED BOARD
PL PLATEPLAM PLASTIC LAMINATEPLAS PLASTICPLBG PLUMBINGPLYWD PLYWOODPNEU PNEUMATICPNL PANELPNT PAINTPNTD PAINTEDPOL POLISHEDPOLY POLYETHYLENEPR PAIRPRCST PRECASTPREFAB PREFABRICATEDPREFIN PREFINISHEDPTD PAPER TOWEL DISPENSERPTN PARTITIONPTR PAPER TOWEL RECEPTACLEPVG PAVING
QT QUARRY TILEQTY QUANTITYQUAL QUALITY
R RISERRAD RADIUSRBR RUBBERRD ROOF DRAINREC RECESSEDREF REFERENCEREFR REFRIGERATORREG REGISTERREINF REINFORCED OR REINFORCINGREM REMOVEABLEREQD REQUIREDRESIL RESILIENTRFG ROOFINGRH RIGHT HANDRHR RIGHT HAND REVERSERLG RAILINGRM ROOMRO ROUGH OPENINGRV ROOF VENTRWL RAIN WATER LEADER
S SOUTHSC SOLID CORESCHED SCHEDULESCRN SCREENSD SOAP DISPENSERSECT SECTIONSGL SINGLESHR SHOWERSHT SHEETSHTHG SHEATHINGSHV SHELVINGSIM SIMILARSK SINKSLV SLEEVESM SHEET METALSND SANITARY NAPKIN DISPENSERSNR SANITARY NAPKIN RECEPTACLESPEC SPECIFICATIONSQ SQUARESSK SERVICE SINKSSP SOLID SURFACE POLYMERSST STAINLESS STEELST STREETSTA STATIONSTC SOUND TRANSMISSION CLASSSTD STANDARDSTL STEELSTOR STORAGESTRUCT STRUCTURALSUSP SUSPENDEDSYM SYMBOL
SYMM SYMMETRICALSYS SYSTEM
T THERMOSTATT&B TOP AND BOTTOMT&G TONGUE AND GROOVETB TOWEL BARTBM TOP OF BEAMTC TOP OF CONCRETETD TEL / DATATEL TELEPHONETEMP TEMPORARYTER TERRAZZOTF TOP OF FOOTINGTFF TOP OF FINISHED FLOORTHK THICKNESSTHRES THRESHOLDTHRU THROUGHTKBD TACKBOARDTMPD TEMPEREDTOL TOLERANCETP TOP OF PAVEMENTTPH TOILET PAPER HOLDERTS TACKABLE SURFACETSL TOP OF SLABTST TOP OF STEELTV TELEVISIONTW TOP OF WALLTYP TYPICAL
U/C UNDER COUNTER UNEX UNEXCAVATEDUNFIN UNFINISHEDUON UNLESS OTHERWISE NOTEDUPS UNINTERRUPTIBLE POWER SUPPLY
UR URINALUV ULTRAVIOLET
VAC VACUUMVAF VISUAL ALARM VCT VINYL COMPOSITION TILEVERT VERTICALVEST VESTIBULEVIF CONTRACTOR TO VERIFY IN FIELDVNR VENEERVR VAPOR RETARDER
W WESTW/ WITHW/O WITHOUTWC WATERCLOSETWD WOODWLD WELDEDWSCT WAINSCOTWT WEIGHTWTRPRF WATERPROOFINGWWF WELDED WIRE FABRIC
CL
1
A1.01
SIM
A1.01
1SIM
TOP OF SLABELEV = 100'-0"
WINDOW / LOUVER SYMBOL
DOOR MARK
ELEVATION /LEVEL MARKER
DATUM POINT ELEV = 100'-0"
1 View Name1/8" = 1'-0"
A
B
C
D A5.10
1
A1.01
SIM
1
A1.01
SIM
1
A1.01
SIM
ACCESSIBILITYCLEARANCES
REVISION SYMBOL
ACCESSIBILITY SYMBOL
BUILDING SECTION
WALL SECTION
DETAIL
PLAN / SECTION DETAIL
ELEVATION INTERIOR
ELEVATION EXTERIOR
SCALE:
1 View Name1/8" = 1'-0"A1.01
VIEW NAME: PLAN,SECTION, ELEVATION, DETAILS
VIEW NAME WITH REFERENCE
COLUMN GRIDS
PARTITION SYMBOL
FN-00FURNITURE SYSTEM SYMBOL
CURTAIN WALL PANEL SYMBOL
EQUIPMENT SYMBOL
#
ROOM TAG
/1 A1.01MATCH LINE
CEILING TYPE/HT.
ROOM NUMBER
APPROX ROOM AREA
SHEET REFERENCE
CEILING TYPE
CEILING HEIGHT
EQUIP. NUMBER
PARTITION TYPE
PANEL TYPE
WINDOW / LOUVER
MARK
COLUMN
NUMBER
FURNITURE
NUMBER
CASEWORK TAGCASEWORK TYPE
1
A5.01
COLUMN LETTER
R 2' - 6"
FINISH TAG
1
001M
12'-6"
TYPE
EQ-00
PL
X1
Room Name101
123 SF
WIN
X
#
1541-AROOM # - PRIMARY, SECONDARY, ECT.
OVERHEAD (OVER COUNTER AND SOFFITS)
CALLOUT
BREAK LINE
GRID LINE
BELOW OR BEYOND (UNDERCOUNTER AND FOOTINGS)
SCOPE OF WORK
CASED OPENING
PAIR
TYPICAL DOOR
DOOR WITH SIDELIGHT
VARYING LEAF
SLIDING
DOUBLE ACTING
TYPICAL WINDOW
EXISTING TO REMAIN
EXISTING TO BE REMOVED
EXISTING WALL
NEW WALL
DEMOLISHED WALL
ALUMINUM
WOOD FINISH
EXISTING BUILDINGS
STEEL
CONCRETE
EARTH
RIGID INSULATION
RUBBER
SAND
GYPSUM BOARD
INSULATION
CMU
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NOT FOR CONSTRUCTION
1/4" = 1'-0"
4/8
/2019
4:3
5:1
1 P
M
A-000179-18-00
04/08/19
GENERAL NOTES,ABBREVIATIONS, LEGENDS
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
ABBREVIATIONS SYMBOLS LINE TYPES
DOORS / WINDOWS / WALLS
MATERIALS
Issuance Schedule
Number Date Description
ELECTRICAL
1205
TENANT
EXHAUST
1210
WOMEN'S
RESTROOM
1206
MEN'S
RESTROOM
1208
EMERG.
ELEC.
1204
TEL /
DATA
1203
SHOWER
1211
JAN
1207
1. WORK WITHIN PHASING AREA (BEHIND PROTECTION BARRIER) TO BE COMPLETED DURING NORMAL HOURS UNLESS INDICATED OTHERWISE ON DRAWINGS.
2. ALL WORK OUTSIDE PHASING AREA TO BE COMPLETED DURING OFF-HOURS (NIGHTS AND WEEKENDS)
3. ALL WORK OUTSIDE PHASING AREA ON THE FLOOR ABOVE OR BELOW, TO BE COMPLETED DURING OFF HOURS (NIGHTS AND WEEKENDS)
4. ALL SHUTDOWNS TO BE COMPLETED DURING OFF-HOURS (NIGHTS AND WEEKENDS).5. ALL SCHEDULING OF WORK SHALL BE COORDINATED WITH THE CLIENT AND/OR AUTHORIZED
REPRESENTATIVE/PROJECT MANAGER.
PHASE 1
PHASE 2
PHASE 3
PHASE 4
PROPOSED PROTECTION BARRIER
CONFERENCEROOM
PHASE 1
PHASE 2
PHASE 3
SCOPE OF WORK
bE.3
bF
bE
bD.9
bD.1
bD.05
bD
bC.3
bC
b1 b1.4 b2 b3 b3.2 b3.5 b4
bB.3
bB.1
bB
bA.1
bA
CONFERENCEROOM CONFERENCE
ROOMBREAKOUT ROOM
COPY/MAIL ROOMPODPODPODPOD
PODPOD
STORAGE
PHASE 4
OPEN OFFICE
CONFERENCEROOM
CONFERENCEROOM
OPEN OFFICE
POD
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NORTH
NOT FOR CONSTRUCTION
As indicated
4/8
/2019
4:3
5:1
2 P
M
A-130179-18-00
04/08/19
PHASING PLAN
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
PHASING NOTES
PHASING PATTERN KEY
SCALE:
1 : 801
LEVEL 12 PHASING PLAN
Issuance Schedule
Number Date Description
ELECTRICAL
1205
TENANT
EXHAUST
1210
WOMEN'S
RESTROOM
1206
MEN'S
RESTROOM
1208
SHOWER
1211
JAN
1207
A. SCOPE OF WORK LINE GENERALLY INDICATES THE AREA OF GREATEST IMPACT DURING RENOVATIONS. EXISTING AREAS OUTSIDE THE SCOPE OF WORK LINE THAT ARE DISTURBED IN ORDER TO COMPLETE THIS AREA ARE CONSIDERED TO BE PART OF THE SCOPE OF WORK WHETHER INDICATED SPECIFICALLY OR NOT. CONTRACTOR SHALL ALLOW FOR REMOVAL AND REPLACEMENT OF EXISTING FINISHES OUTSIDE THE SCOPE OF WORK LINE IN ORDER TO COMPLETE THE WORK.
B. SEE HOURS OF WORK REQUIREMENTS AND COORDINATE DEMOLITION ACTIVITIES ACCORDINGLY.C. REFER TO ALL OTHER CONSULTANT AND VENDOR DRAWINGS AND SPECIFICATIONS FOR EXTENT AND
REQUIREMENTS OF REMOVAL/SALVAGE/RELOCATION OF STRUCTURAL, PLUMBING/FIRE PROTECTION, MECHANICAL AND ELECTRICAL ITEMS. COORDINATE WITH ALL ASSOCIATED TRADES.
D. REFER TO DIV. 01 SECTION "CUTTING AND PATCHING" FOR REQUIREMENTS RELATED TO CUTTING AND PATCHING DUE TO DEMOLITION ACTIVITIES.
E. REFER TO DEMOLITION SPECIFICATION (DIVISION 01) FOR REQUIREMENTS RELATED TO DEMOLITION ACTIVITIES.
F. DISPOSE OF ALL DEMOLITION ITEMS IN ACCORDANCE WITH PROJECT SPECIFICATIONS. G. REMOVE ALL ITEMS SHOWN AS DASHED LINES ON THE DEMOLITION DRAWINGS, INCLUDING ALL
ASSOCIATED FITTINGS AND ACCESSORIES ASSOCIATED WITH ITEM(S) BEING REMOVED.H. DEMOLITION KEYNOTES NOT SPECIFICALLY TAGGING AN INDIVIDUAL ITEM (NO LEADER ARROW)
REFER TO ALL ITEMS WITHIN THE ROOM OR AREA IN WHICH THE NOTE IS LOCATED. I. WHERE A PARTITION IS SHOWN TO BE DEMOLISHED, CONTRACTOR TO REMOVE ALL WALL MOUNTED
FIXTURES/FITTINGS/EQUIPMENT. J. FIRE RATINGS TO BE MAINTAINED AT ALL RATED ASSEMBLIES AT ALL TIMES. K. FOR THE PURPOSES OF A COMPLETE SCOPE OF WORK THE CONTRACTOR IS TO ASSUME THAT ALL
EXISTING WALLS TO BE DEMOLISHED THAT ARE GREATER THAN 8" THICK ARE CHASE WALLS, CONTINUOUS TO ADJACENT FLOORS AND WILL REQUIRE PATCHING.
L. RELOCATION OF ALL EQUIPMENT TO BE COORDINATED WITH OWNER.M. PROVIDE TEMPORARY SUPPORTS FOR PORTION OF DEMOLISHED WALLS TO REMAIN.
SCOPE OF WORK
/1 A-141/1 A-141
bE.3
bF
bE
bD.9
bD.1
bD.05
bD
bC.3
bC
b1 b1.4 b2
1114
11 14
11
01
01
14
03
b3 b3.2 b3.5 b4
CONFERENCEROOM12113
CONFERENCEROOM12031
BREAKOUTSPACE12032
COPY ROOM12012
POD12011
POD12010
POD12009
POD12008
COPY / MAIL12007
CORRIDOR12002
OPEN WORK AREA12084
CONFERENCE ROOM12083
CONFERENCE ROOM12082
OPEN WORK AREA12081
CONFERENCEROOM12029
14STORAGE
12005
14
EXTENT OF CARPETDEMOLITION
20
20
EXTENT OF CARPETDEMOLITION
20
2020
20
20 20 20 20 20
20 20
31
31
31
31
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NORTH
NOT FOR CONSTRUCTION
1/4" = 1'-0"
4/8
/2019
4:3
5:1
3 P
M
A-140179-18-00
04/08/19
DEMOLITION PLAN NORTH,GENERAL NOTES, KEYS,LEGENDS
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
GENERAL DEMOLITION NOTES
SPECIFIC DEMOLITION NOTES
01 REMOVE PORTION OF GYPSUM BOARD PARTITION AS INDICATED.
03 REMOVE PORTION GYPSUM BOARD PARTITION IN COORDINATION WITH NEW DOOR AND/OR WINDOW.
11 REMOVE AND SALVAGE DOOR, HARDWARE AND ALL ASSOCIATED FITTINGS.
14 REMOVE AND SALVAGE GLASS PARTITION, FRAME AND ALL ASSOCIATED FITTINGS.
20 REMOVE FLOORING TO SUBFLOOR OR FLOORING SUITABLE SURFACE FOR INSTALLATION OF NEWFLOOR (COORDINATE WITH FINISH PLAN).
31 REMOVE PORTION OF CEILING/SOFFITS AND ALL ASSOCIATEDFRAMING/FIXTURES/DEVICES/EQUIPMENT (COORDINATE WITH MEP/FP/STRUCTURAL).
SCALE:
1/4" = 1'-0"1
LEVEL 12 DEMOLITION PLAN NORTH
Issuance Schedule
Number Date Description
/1 A-140 /1 A-140
bC
b1 b1.4 b2
01
03
03
03
bB.3
bB.1
bB
bA.1
bA
OPEN WORK AREA12081
TRAINING ROOM
30
10
10
20
20
2031
31
31
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NORTH
NOT FOR CONSTRUCTION
1/4" = 1'-0"
4/8
/2019
4:3
5:1
4 P
M
A-141179-18-00
04/08/19
DEMOLITION PLAN SOUTH
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
SPECIFIC DEMOLITION NOTES
01 REMOVE PORTION OF GYPSUM BOARD PARTITION AS INDICATED.
03 REMOVE PORTION GYPSUM BOARD PARTITION IN COORDINATION WITH NEW DOOR AND/OR WINDOW.
10 REMOVE DOOR, FRAME, HARDWARE AND ALL ASSOCIATED FITTINGS/LIGHTS.
20 REMOVE FLOORING TO SUBFLOOR OR FLOORING SUITABLE SURFACE FOR INSTALLATION OF NEW FLOOR(COORDINATE WITH FINISH PLAN).
30 REMOVE CEILING/SOFFITS AND ALL ASSOCIATED FRAMING/FIXTURES/DEVICES/EQUIPMENT (COORDINATEWITH MEP/FP/STRUCTURAL).
31 REMOVE PORTION OF CEILING/SOFFITS AND ALL ASSOCIATED FRAMING/FIXTURES/DEVICES/EQUIPMENT(COORDINATE WITH MEP/FP/STRUCTURAL).
SCALE:
1/4" = 1'-0"1
LEVEL 12 DEMOLITION PLAN SOUTH
Issuance Schedule
Number Date Description
ELECTRICAL
1205
TENANT
EXHAUST
1210
WOMEN'S
RESTROOM
1206
MEN'S
RESTROOM
1208
SHOWER
1211
JAN
1207
1. ALL WORK SHALL BE PERFORMED PER APPLICABLE CODES, ORDINANCES AND PER REQUIREMENTS OF ALL APPLICABLE REGULATORY AGENCIES AND AUTHORITIES HAVING JURISDICTION.
2. ALTERATIONS/RENOVATIONS ON THIS AND OTHER FLOORS NOT SPECIFICALLY CALLED OUT AS RENOVATION AREAS ARE TO BE DONE AS NECESSARY TO COMPLETE WORK SHOWN ON THE CONTRACT DOCUMENTS. REFER TO ENGINEER CONSULTANT AND VENDOR DRAWINGS TO IDENTIFY THE SCOPE OF WORK IN AREAS IDENTIFIED OUTSIDE THE ARCHITECTURAL DOCUMENTS. THE G.C. SHALL BE RESPONSIBLE FOR THE REMOVAL AND RESTORATION OF ALL EXISTING FINISHES DISTURBED BY THE WORK. WHERE TEMPORARY M.E.P. CONNECTIONS ARE REQUIRED, ALL FINISHES SHALL BE RESTORED IMMEDIATELY TO MAINTAIN OPERATION OF THE FACILITY, EVEN IF THE WORK WILL REQUIRE TO BE REMOVED AGAIN DURING THIS PROJECT.
3. ALL OPENINGS, IN EXISTING FLOORS AND WALLS ABOVE AND BELOW THE CEILING PLENUM, BOTH EXISTING AND AS A RESULT OF DEMOLITION ACTIVITIES SHALL BE PATCHED TO COMPLETE AND FINISH EXISTING WALLS AND FLOORS CONSISTENT WITH NEW WORK. ALL PATCHES SHALL BE MADE WITH MATERIALS CONSISTENT WITH THE WALL IN WHICH THE PATCH WILL BE LOCATED.
4. THE G.C. SHALL COORDINATE AND SCHEDULE ALL WORK WITH THE CLIENT AND/OR CLIENTS AUTHORIZED REPRESENTATIVE/PROJECT MANAGER. WORK SCHEDULED IN OCCUPIED AREAS SHALL BE UNDERTAKEN IN A MANNER SO AS NOT TO DISTURB THE OPERATION OF THE FACILITY.
5. WHERE A NEW SERVICE PENETRATES AN EXISTING WALL WHICH EXTENDS TO THE UNDERSIDE OF THE STRUCTURE, THE G.C. WILL BE RESPONSIBLE FOR PATCHING AND FIRE SAFING THE WALL AND FOR PROVIDING THE REQUIRED FIRE RATING AND FINISH.
6. PROVIDE BLOCKING IN WALL THROUGHOUT AS INDICATED ON DRAWINGS FOR ALL WALL MOUNTED ITEMS, INCLUDING ITEMS FURNISHED BY OWNER.
7. ITEMS IDENTIFIED AS NOT IN CONTRACT (NIC) ARE TO BE PURCHASED AND INSTALLED BY THE OWNER. THE G.C. SHALL COORDINATE INSTALLATION OF ALL ITEMS NIC WITH THE OWNER.
8. PROVIDE ALL HEADERS, LINTELS AND SUPPORTS AS NECESSARY FOR ALL WALLS AND PARTS OF WALLS SHOWN TO BE REMOVED. ALL NEW MEMBERS SHALL BE IN CONFORMANCE WITH THE MASSACHUSETTS STATE BUILDING CODE, 9TH EDITION. THE GC IS RESPONSIBLE FOR IDENTIFYING ANY STRUCTURAL BEARING CONDITIONS THAT BECOME APPARENT DURING DEMOLITION. ANY FOUND STRUCTURAL CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO REMOVAL OF STRUCTURAL MEMBERS.
9. IT IS THE INTENT OF THIS DOCUMENT THAT ALL NEW WIRING, PIPING FIXTURES, FITTINGS AND DEVICES BE RECESSED INTO EXISTING WALLS. THE CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING, PATCHING, REPAIRING, ETC. AS REQUIRED TO RECESS ITEMS IDENTIFIED ABOVE.
10. WHERE WALL MOUNTED ITEMS HAVE BEEN REMOVED, PATCH AND REPAIR EXISTING WALL.
1. ALL WALL PARTITIONS TO BE TYPE "B" UNLESS OTHERWISE NOTED.2. WHERE NEW WALL IS NOT DIMENSIONED LAYOUT TO ASSUME NEW WALL IS ALIGNED WITH
ADJACENT WALL.3. ALL PARTITIONS ARE TO EXTEND TO THE UNDERSIDE OF THE EXISTING DECK AND TO BE SEALED
ON BOTH SIDES.4. ALL PENETRATIONS IN SMOKE AND FIRE RATED PARTITIONS ABOVE CEILING TO BE FIRE
STOPPED.5. ALL PENETRATIONS IN NON-RATED PARTITIONS ABOVE CEILING TO BE SEALED.
SCOPE OF WORK
CONFERENCEROOM12029
/1 A-151/1 A-151
bE.3
bF
bE
bD.9
bD.1
bD.05
bD
bC.3
bC
b1 b1.4 b2 b3 b3.2 b3.5 b4
CONFERENCEROOM12113
CONFERENCEROOM12031
BREAKOUT ROOM12032
COPY/MAIL ROOM12012
POD12011
POD12010
POD12009
POD12008
POD12007
POD12006
CONFERENCEROOM12082
CONFERENCEROOM12083
A
A
A
6'-0"
CORRIDOR12002
OPEN OFFICE12084
CORRIDOR12001
1200
1-A
12082-A
12083-A
A-210
12C
OPEN OFFICE12081
12002-A
A-210
11C
STORAGE12005
1200
6-A
1200
7-B
PATCH CARPET IN COORDINATIONWITH DEMO & NEW WORK, TYP.
CPT-1
CPT-1
PT-4PT-4
A-210
10C
A-21023B22D
PT-4PT-4 PT-4PT-4
PT-4
PT-4
CPT-2
CPT-3
RB-1
CPT-1
CPT-2
CPT-3
RB-1
CPT-1
CPT-2
CPT-3
RB-1
CPT-1
CPT-2
CPT-3
RB-1
CPT-1
CPT-2
CPT-3
RB-1
CPT-1
CPT-2
CPT-3
RB-1
CPT-1
CPT-2
CPT-3
RB-1
A-21013B
+/-
18'-0
"
PT-2
PT-2
PT-3 PT-3
CPT-1
CPT-2
CPT-3
RB-1
CPT-1
CPT-2
CPT-3
RB-1 CPT-1
CPT-2
CPT-3
RB-1
CPT-1
CPT-2
CPT-3
RB-1
CPT-1
CPT-2
CPT-3
RB-1
CPT-1
CPT-2
CPT-3
RB-1
CPT-1
CPT-2
CPT-3
RB-1
A-760
24
CARPET
1. ALL WALLS AND SOFFITS TO BE PAINTED PT-1 , UNLESS OTHERWISE NOTED.2. PROVIDE TRANSITION STRIPS AT ALL CHANGE IN FLOORING MATERIAL INTERSECTIONS.3. STRAIGHT BASE AT CARPET. COVE BASE AT ALL OTHER FLOORING.4. SOFFITS AT ACCENT PAINT WALLS TO BE PAINTED ACCENT COLOR.5. ALL FLOORING TO CONTINUE UNDER MILLWORK/CASEWORK UNLESS OTHERWISE NOTED.6. FINISH TAGS NOT SPECIFICALLY TAGGING AN INDIVIDUAL ITEM (NO LEADER ARROW) OR NOT
ASSOCIATED WITH A HATCH, REFER TO ALL ITEMS WITHIN THE ROOM OR AREA IN WHICH THE NOTE IS LOCATED.
ACT ACOUSTIC CEILING TILECPT CARPET TILEPT PAINTRB RESILIENT BASE
Z LOCKER: EXISTING TO BE RELOCATED AND REINSTALLED BY GENERAL CONTRACTOR
ADD ALTERNATE #1: REFER TO E1.12
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NORTH
NOT FOR CONSTRUCTION
1/4" = 1'-0"
4/8
/2019
4:3
5:1
4 P
M
A-150179-18-00
04/08/19
FLOOR PLAN NORTH,GENERAL NOTES, KEYS,LEGEND
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
GENERAL NOTES
PARTITION NOTES
SCALE:
1/4" = 1'-0"1
LEVEL 12 NEW WORK PLAN NORTH
FINISH FLOOR PATTERN KEY
FINISH SCHEDULE
FINISH MANUFACTURER STYLE/NUMBER COLOR
ACT-1 ARMSTRONG OPTIMA 3251 WHITE
CPT-1 TBD TBD TBD
CPT-2 TBD TBD TBD
CPT-3 TBD TBD TBD
PT-1 SHERWIN WILLIAMS OC-122 COTTON BALLS
PT-2 SHERWIN WILLIAMS TBD ACCENT PAINT
PT-3 SHERWIN WILLIAMS TBD ACCENT PAINT
PT-4 TBD TBD IDEA PAINT
RB-1 JOHNSONITE 4" TRADITIONAL 01 SNOW WHITE
FINISH NOTES
ABBREVIATIONS - FINISHES
ACCESSORY KEY
Issuance Schedule
Number Date Description
ALTERNATES
/1 A-150 /1 A-150
bC
b1 b1.4 b2
bB.3
bB.1
bB
bA.1
bA
POD12079
OPEN OFFICE12081
12001-B
12079-A
01
G G
A-21020B
A-21021B
CPT-1
CPT-2
CPT-3
RB-1
CPT-1
CPT-2
CPT-3
RB-1
PT-4
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NORTH
NOT FOR CONSTRUCTION
1/4" = 1'-0"
4/8
/2019
4:3
5:1
5 P
M
A-151179-18-00
04/08/19
FLOOR PLAN SOUTH
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
SCALE:
1/4" = 1'-0"1
LEVEL 12 NEW WORK PLAN SOUTH
Issuance Schedule
Number Date Description
ELECTRICAL
1205
TENANT
EXHAUST
1210
WOMEN'S
RESTROOM
1206
MEN'S
RESTROOM
1208
SHOWER
1211
JAN
1207
1. ALL TYPICAL ACT CEILING HEIGHTS TO MATCH EXISTING UNLESS OTHERWISE NOTED.2. CEILINGS SHALL NOT BE INSTALLED WITHOUT REVIEWED MEP COORDINATION DRAWINGS AS
REQUIRED BY THE PROJECT SPECIFICATIONS.3. AT NO TIME SHALL THE CONTRACTOR ADJUST THE CEILING HEIGHT AS INDICATED ON
DOCUMENTS WITHOUT REVIEW WITH ARCHITECT. ARCHITECT SHALL BE INFORMED OF ALL CEILING HEIGHT CONFLICTS WHEN DISCOVERED FOR REVIEW.
4. COORDINATE ALL SOFFITS ABOVE CABINETS WITH INTERIOR ELEVATIONS AND CASEWORK DETAILS.
5. ALL DEVICES SHALL BE ALIGNED AND CENTERED WITHIN GRID UNLESS OTHERWISE NOTED. 6. REFER TO ALL ENGINEERING CONSULTANT AND VENDOR DRAWINGS FOR ALL RELATED SCOPE
FOR COORDINATION.
2'x2' SUPPLY DIFFUSER
NEW CEILING GRID WITH NEW 2'x2' ACOUSTICAL PANEL CEILING
NEW SOFFIT
2'x2' RETURN REGISTER
EXIT SIGN
SMOKE DETECTOR
RECESSED DOWN LIGHT
2'x2' RECESSED LIGHT FIXTURE
SPRINKLER
EXISTING CEILING GRID WITH EXISTING 2'x2' ACOUSTICAL PANEL CEILING
EXISTING SOFFIT
1'x4' PENDANTLIGHT FIXTURE
1'x4' RECESSED LIGHT FIXTURE
MOTION SENSOR
SPEAKER
WIRELESS ACCESS POINT
/1 A-171 /1 A-171
SCOPE OF WORK
bE.3
bF
bE
bD.9
bD.1
bD.05
bD
bC.3
bC
b1 b1.4 b2 b3 b3.2 b3.5 b4
CONFERENCEROOM12083
CONFERENCEROOM12082
CONFERENCEROOM12029
POD12006
POD12007
POD12008
POD12009
POD12010
POD12011
COPY/MAIL ROOM12012
BREAKOUT ROOM12032
CONFERENCEROOM12031
CONFERENCEROOM12113
9' - 0"
ACT
ALIGN
ALI
GN
CORRIDOR12002
OPEN OFFICE12084
OPEN OFFICE12081
STORAGE12005
1' -
11
3/8"
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NORTH
NOT FOR CONSTRUCTION
1/4" = 1'-0"
4/8
/2019
4:3
5:1
6 P
M
A-170179-18-00
04/08/19
REFLECTED CEILING PLANNORTH, GENERAL NOTES,KEYS, LEGENDS
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
GENERAL CEILING NOTES
CEILING PLAN KEY
SCALE:
1/4" = 1'-0"1
LEVEL 12 REFLECTED CEILING PLAN NORTH
Issuance Schedule
Number Date Description
/1 A-170 /1 A-170
9' - 0"
ACT
bC
b1 b1.4 b2
bB.3
bB.1
bB
bA.1
bA
POD12079
OPEN OFFICE12081
8' - 0"
ACT
ALI
GN
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NORTH
NOT FOR CONSTRUCTION
1/4" = 1'-0"
4/8
/2019
4:3
5:1
7 P
M
A-171179-18-00
04/08/19
REFLECTED CEILING PLANSOUTH
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
SCALE:
1/4" = 1'-0"1
LEVEL 12 - REFLECTED CEILING PLAN SOUTH
Issuance Schedule
Number Date Description
ELECTRICAL
1205
TENANT
EXHAUST
1210
WOMEN'S
RESTROOM
1206
MEN'S
RESTROOM
1208
SHOWER
1211
JAN
1207
CONFERENCEROOM12029
/1 A-181/1 A-181
bE.3
bF
bE
bD.9
bD.1
bD.05
bD
bC.3
bC
b1 b1.4 b2 b3 b3.2 b3.5 b4
CONFERENCEROOM12113
CONFERENCEROOM12031
BREAKOUT ROOM12032
POD12011
POD12010
POD12009
POD12008
POD12007
POD12006
COPY/MAIL ROOM12012
CONFERENCEROOM12083
CONFERENCEROOM12082
OPEN OFFICE12084
OPEN OFFICE12081
02
03 03
01 01 01 01 01
FN-01 FN-01 FN-01
FN-01 FN-01 FN-01
FN-01 FN-01 FN-01
FN-01FN-01FN-01
FN-03 FN-03 FN-03
FN-03 FN-03 FN-03
FN-03 FN-03 FN-03
FN-03 FN-03 FN-03
FN-04 FN-04 FN-04 FN-04 FN-04
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01 FN-01
FN-01
FN-01 FN-01
FN-01
FN-01 FN-01
FN-01
FN-01 FN-01
FN-01
FN-01 FN-01
FN-01
FN-01
FN-01
FN-02 FN-02 FN-02 FN-02 FN-02
FN-02FN-02
FN-02 FN-02 FN-02 FN-02 FN-02
FN-02
FN-02 FN-02 FN-02 FN-02 FN-02
FN-02
FN-02FN-02FN-02FN-02FN-02
FN-01
FN-01 FN-01 FN-01
FN-01FN-01FN-01 FN-01 FN-01 FN-01
FN-01FN-01FN-01
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03 FN-03
FN-03
FN-03 FN-03
FN-03
FN-03 FN-03
FN-03
FN-03 FN-03
FN-03
FN-03 FN-03
FN-03
FN-03
FN-03FN-03 FN-03 FN-03 FN-03 FN-03 FN-03
FN-03FN-03FN-03FN-03FN-03FN-03
FN-05 FN-05 FN-05 FN-05 FN-05
04
FN-06 FN-06FN-07
FN-07
FN-07
FN-07
FN-01 FN-01
FN-01 FN-01
FN-01 FN-01
FN-01 FN-01
FN-08
FN-08
FN-09 FN-09
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NORTH
NOT FOR CONSTRUCTION
1/4" = 1'-0"
4/8
/2019
4:3
5:1
9 P
M
A-180179-18-00
04/08/19
FFE PLAN NORTH
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
SCALE:
1/4" = 1'-0"1
LEVEL 12 FFE PLAN NORTH
Issuance Schedule
Number Date Description
/1 A-180 /1 A-180
bC
b1 b1.4 b2
bB.3
bB.1
bB
bA.1
bA
POD12079
OPEN OFFICE12081
02
01
FN-04
FN-05
FN-05
FN-01
FN-01
FN-01 FN-01
FN-01
FN-01 FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01 FN-01 FN-01
FN-01FN-01FN-01
FN-01FN-01FN-01FN-01
FN-01 FN-01 FN-01 FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-01 FN-01
FN-01
FN-01
FN-01 FN-01
FN-01
FN-01
FN-01
FN-01
FN-01 FN-01
FN-01
FN-01
FN-01
FN-01
FN-01
FN-03
FN-03
FN-03 FN-03
FN-03
FN-03 FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03
FN-03 FN-03
FN-03
FN-03
FN-03 FN-03 FN-03 FN-03
FN-03 FN-03 FN-03 FN-03
FN-03 FN-03 FN-03
FN-03FN-03FN-03
FN-03
FN-03
FN-03
FN-03 FN-03
FN-03
FN-03
FN-03 FN-03
FN-03
FN-03
FN-03 FN-03
FN-03
FN-03
FN-03 FN-03
FN-03
FN-03
FN-03 FN-03
FN-03
FN-03
FN-03
04
FN-06 FN-06
FN-07
FN-07
FN-07
FN-01 FN-01
FN-01 FN-01
FN-01 FN-01
FN-01 FN-01
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NORTH
NOT FOR CONSTRUCTION
1/4" = 1'-0"
4/8
/2019
4:3
5:2
0 P
M
A-181179-18-00
04/08/19
FFE PLAN SOUTH &SCHEDULES
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
SCALE:
1/4" = 1'-0"1
LEVEL 12 FFE PLAN - SOUTH
FURNITURE SCHEDULE
TYPEMARK TYPE MANUFACTURER MODEL WIDTH HEIGHT DEPTH
PURCHASEDBY
INSTALLEDBY COMMENTS
FN-01 TASK CHAIR Herman Miller, Inc. AE112HWB
FN-02 CHAIR Herman Miller, Inc. AE112HWB
FN-03 MOBILE PED 1' - 6" 2' - 0" 2' - 1" OWNER FURNITURE VENDOR
FN-04 24DIAM 24H OWNER
FN-05 TASK, ARMLESS 2' - 1" 2' - 11" 2' - 3" OWNER
FN-06
FN-07
FN-08
FN-09
EQUIPMENT SCHEDULE
TYPEMARK TYPE MANUFACTURER MODEL F/T/UC WATER POWER VOLTS AMPS WIDTH HEIGHT DEPTH
PURCHASEDBY INSTALLED BY COMMENTS
01 POD MONITOR 3' - 0" 2' - 0" 4" OWNER GENERAL CONTRACTOR
02 PRINTER Sharp F0-4450 OWNER
03 MONITOR 60" 5' - 0" 3' - 0" 4" OWNER GENERAL CONTRACTOR
04 SHREDDER BOX 1' - 0" 2' - 0" 1' - 0" OWNER
TABLE
SIT/STAND
OWNER
OWNER
OWNER
OWNER
Issuance Schedule
Number Date Description
DESK
CONFERENCE TABLE
OWNER
OWNER
AS90 12
TYP. VOICE / DATA OUTLETS
FIRE EXTINGUISHER/FIRE EXTINGUISHER
CABINET
CL
CL
5' -
0"
4' -
0"
1' -
6"
DOOR ACTUATORPUSH PAD
CL
4' -
0"
4' -
0"
4' -
0"
CL
4' -
8"
THERMOSTAT
WALL PHONE
LIGHT SWITCH PLATE
AUDIO / VISUALALARM
6' -
8"
4' -
0"
FIRE ALARM PULL STATION
CLCL
4' -
0"
LS
TYP. LIGHT SWITCH
CL
4' -
0"
SLC
TYP. LIGHTING CONTROL SENSOR
THERMOSTAT
5' -
0"
TST
EXIT SIGNTYP. ELECTRICALOUTLETS
CL
1' -
6"
CARD ACCESS
CL
4' -
0"
1' - 0"
GENERAL NOTE: HEIGHTS INDICATED ARE FOR GENERAL CONDITIONS, UNLESS OTHERWISE NOTED. REFER TO INTERIOR ELEVATIONS FOR SPECIFIC MOUNTING HEIGHTS.
6'-8
" M
IN
TYP. EMERGENCYELECTRICAL
OUTLETS
CL
1' -
6"
EOOT
MONITOR
CL EQEQ
DISASSEMBLE & SALVAGE GLAZED WALL TO NEAREST JOINT. REINSTALL MODIFIED GLAZED WALL IN COORDINATION WITH NEW DOOR AND
FRAME
DISASSEMBLE & SALVAGE GLAZED WALL TO NEAREST JOINT. REINSTALL MODIFIED GLAZED WALL IN COORDINATION WITH NEW DOOR AND
FRAME
DISASSEMBLE & SALVAGE GLAZED WALL TO NEAREST JOINT. REINSTALL MODIFIED GLAZED WALL IN COORDINATION WITH NEW DOOR AND FRAME
RACO C2-01A CORNER MULLION
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NOT FOR CONSTRUCTION
1/4" = 1'-0"
4/8
/2019
4:3
5:2
1 P
M
A-210179-18-00
04/08/19
INTERIOR ELEVATIONS
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
1/4" = 1'-0"12CCOPY/MAIL ROOM
TYPICAL MOUNTING HEIGHTS
1/4" = 1'-0"11CTYPICAL POD
1/4" = 1'-0"20BNEW POD DOOR
1/4" = 1'-0"21BOPEN OFFICE
1/4" = 1'-0"10CCORRIDOR (12002)
Issuance Schedule
Number Date Description
1/4" = 1'-0"23BCONFERENCE ROOM 12083
1/4" = 1'-0"22DCONFERENCE ROOM 12082
1/4" = 1'-0"13BOPEN OFFICE 12084
PROVIDE SAFB ABOVE RUNNER WHERE WALL RUNS PERPENDICULAR TO DIRECTION OF DECK AT B PARTITION
JOINT SEALER AND BACKING EACH SIDE
PROVIDE CASING BEAD WHERE EXPOSED TO VIEW
CEILING RUNNER
DEFLECTION ALLOWANCE
SAFB (SOUND ATTENUATION FIRE BLANKET) 3" MINERAL WOOL BATT)
SUSPENDED CEILINGWHERE SCHEDULED
METAL STUDS
5/8" GYPSUM BOARD-AT 1 HOUR PARTITION USE5/8" TYPE X GYPSUM BOARD
SCHEDULED BASE
FLOOR RUNNER
JOINT SEALER AND BACKING EACH SIDE
TOP OF SLAB
(7 1/4")
BA
SE
PLA
NC
EIL
ING
HE
AD
B
B1
B2
B3
NO FIRE RESISTANCE RATINGSTC = 49 TEST# SA-870717
1 HOUR FIRE - UL# U465STC = 49 TEST# SA-870717
NO FIRE RESISTANCE RATINGSTC = 49 TEST# SA-870717
1 HOUR FIRE - UL# U465STC = 49 TEST# SA-870717
4 7/8" (3 5/8" STUD)
4 7/8" (3 5/8" STUD)
7 1/4" (6" STUD)
7 1/4" (6" STUD)
4 7/8"
UNDERSIDE OF STRUCTURE
MULTIPLE LAYERS OF GYPSUM BOARD (WHERE INDICATED)
MULTIPLE LAYERS OF JOINT SEALER AND BACKING WHERE MULTIPLE LAYERS OF GYPSUM BOARD ARE SHOWN
FLOOR RUNNER
3/8"
TY
PIC
AL
JOINT SEALER AND BACKING
-PROVIDE FIRE STOPPING AT FIRE RATED PARTITIONS
- PROVIDE SMOKE STOPPING AT SMOKE PARTITIONS
- PROVIDE ACOUSTICAL SEALANT AT ACOUSTICAL PARTITIONS
GYPSUM BOARD
SCHEDULED BASE
5" UNLESS OTHERWISE NOTED
UNDERSIDE OF STRUCTURE
JOINT SEALER AND BACKING EACH SIDE
PROVIDE CASING BEAD WHERE EXPOSED TO VIEW
CEILING RUNNER
SAFB (SOUND ATTENUATION FIRE BLANKET) 3" MINERAL WOOL BATT)
SUSPENDED CEILINGWHERE SCHEDULED
METAL STUDS
5/8" GYPSUM BOARD-AT 1 HOUR PARTITION USE5/8" TYPE X GYPSUM BOARD
SCHEDULED BASE
FLOOR RUNNER
JOINT SEALER AND BACKING EACH SIDE
TOP OF SLAB
BA
SE
PLA
NC
EIL
ING
HE
AD
VIF
A
A1
NO FIRE RESISTANCE RATINGSTC = 49 WITH 3 5/8" METAL STUDS - TEST# SA-870717
1 HOUR FIRE WITH 3 5/8" METAL STUDS - UL# U465STC = 49 WITH 3 5/8" METAL STUDS - TEST# SA-870717
WIDTH VIF (EXISTING STUD)
WIDTH VIF (EXISTING STUD)
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NOT FOR CONSTRUCTION
As indicated
4/8
/2019
4:3
5:2
2 P
M
A-710179-18-00
04/08/19
TYPICAL PARTITIONDETAILS
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
SCALE:
SECTION DETAIL
1 1/2" = 1'-0"11 PARTITION TYPE B, B1, B2, AND B3
SCALE:
SECTION DETAIL
3" = 1'-0"21 TYPICAL PARTITION AT BASE DETAIL
SCALE:
PLAN DETAIL
3/4" = 1'-0"20 DOOR FRAME LOCATION
SCALE:
SECTION DETAIL
1 1/2" = 1'-0"10 PARTITION TYPE A AND A1
Issuance Schedule
Number Date Description
SEE CEILING PLANFOR HEIGHT
6" M
IN.
VA
RIE
S
CORNER BEAD
5/8" GYPSUM BOARD
ACOUSTICAL CEILING SYSTEM
5/8" GYPSUM BOARD
3 5/8" METAL STUD TO UNDERSIDE OF STRUCTURE
SEE CEILING PLANFOR HEIGHT
5/8" GYPSUM BOARD
CHANNEL
VA
RIE
S
SEE CEILING PLANFOR HEIGHT
RIGID FURRING CHANNEL
5/8" GYPSUM BOARD
METAL ANGLE
CORNER BEAD
3 5/8" METAL STUD BRACE TOUNDERSIDE OF STRUCTURE
3 5/8" METAL STUD BRACE TOUNDERSIDE OF STRUCTURE
SEE CEILING PLANFOR HEIGHT
5/8" GYPSUM BOARD
5/8" GYPSUM BOARD
SEE CEILING PLANFOR HEIGHT
6" M
IN.
VARIES
2" U
ON
2" U
ON
5/8" GYPSUM BOARD
CORNER BEAD
METAL CHANNEL
3 5/8" METAL STUD BRACE TO UNDERSIDE OF STRUCTURE
3 5/8" METAL STUD BRACE TO UNDERSIDE OF STRUCTURE
6" M
IN.
45.00°
VA
RIE
S SEE CEILING PLANFOR HEIGHT
VARIES
ACOUSTICAL CEILING SYSTEM
EDGE TRIM
CORNER BEAD
5/8" GYPSUM BOARD
5/8" GYPSUM BOARD
3 5/8" METAL STUD BRACE TO UNDERSIDE OF STRUCTURE
3 5/8" METAL STUD BRACE TO UNDERSIDE OF STRUCTURE
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NOT FOR CONSTRUCTION
1 1/2" = 1'-0"
4/8
/2019
4:3
5:2
2 P
M
A-720179-18-00
04/08/19
TYPICAL REFLECTEDCEILING DETAILS
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
SCALE:
SECTION DETAIL
1 1/2" = 1'-0"10 CHANGE IN MATERIAL
SCALE:
SECTION DETAIL
1 1/2" = 1'-0"11 CHANGE IN MATERIAL HEIGHT
SCALE:
SECTION DETAIL
1 1/2" = 1'-0"13 CHANGE IN CEILING
SCALE:
SECTION DETAIL
1 1/2" = 1'-0"12 TYPICAL SOFFIT / FASCIA AT GYP CEILING
Issuance Schedule
Number Date Description
VA
RIE
S
VARIES
VA
RIE
S
VARIES
14
A-760
14
A-760
13
A-760
13
A-760
11
A-760
20
A-760
12
A-760
10
A-760
A SINGLE C SINGLE WITH SIDELITE
TEMPERED GLAZING
MANUFACTUER:WILSON PARTITIONSKNOCK DOWN ALUMINUM FRAMEFINISH TO BE CLEAR ANODIZED
DOOR AND WINDOW CONSTRUCTION:
ACOUS ACOUSTICAL CORE WOODAC ALUMINUM CLAD WOODAL ALUMINUM HC HOLLOW CORE WOODHM HOLLOW METALLL LEAD LINED FRAME SC SOLID CORE WOODSS STAINLESS STEELTG TEMPERED SAFETY GLASS
DOOR GLASS TYPE:
-- NO GLASS REQUIREDCR CLEAR WIREDFR FIRE RATED PER SPECIFICATIONSIG INSULATING GLASSLG LAMINATED GLASSTF CLEAR TEMPERED FLOATTI TEMPERED INSULATINGLE LEAD GLASS
FRAME CONSTRUCTION:
AC ALUMINUM CLAD WOODAL ALUMINUMPS PRESSED STEELSS STAINLESS STEELWD WOOD
DOOR FACING AND FINISH:
AF ALUMINUM FACTORY FINISHCC COPPER CLADDINGCL HARDWOOD, TRANSPARENT FINISHMF METAL FACTORY FINISHMP METAL PAINTEDWD WOOD PAINTED
FIRE RATING:
BLANK NO FIRE RATING REQUIREDA180 3 HOUR RATING ('A' LABEL REQUIRED)B60 1 HOUR RATING (B LABEL REQUIRED)B90 1- 1/2 HOUR RATING ('B' LABEL REQUIRED)C45 3/4 HOUR ('C' LABEL REQUIRED)20 1/3 HOUR RATING 30 1/2 HOUR RATING
REMARKS:
1. TRANSOM OR SIDELIGHT ADJACENT2. SPECIAL HEIGHT DOOR3. SPECIAL ALUMINUM DOOR AND FRAME4. SECURITY TIE IN REQUIREMENTS5. SPECIAL WOOD DOOR AND FRAME6. SOUND GASKETING7. WEATHERING STRIP8. MAGNETIC HOLD OPENS9. LIGHT GASKET10. FIELD MEASUREMENT REQUIRED11. DOUBLE ACTING REMOVE FRAME STOP12. LEAD LINING REQUIRED13. AUTOMATIC DOORS14. CODE ACCESS HARDWARE15. EXISTING DOOR16. STAINLESS STEEL KICK PLATE17. ROTON HINGE
VARIES
VA
RIE
S
F FLUSH
MANUFACTUER:VT INDUSTRIESSOLID CORE WOOD DOOR, RIFT CUTFINISH TO BE RED OAK
22
A-760
23
A-76021
A-760
3' -
4"
VARIES
01
TEMPERED GLAZING
4' -
0"
7' -
4"
1 1/2"
GWB PARTITION
METAL STUD
ALUMINUM MULLION
GLAZING
GWB PARTITION
METAL STUD
ALUMINUM FRAME
GLAZING
1 1/
2"
1 1/2"
3/4"
1"
1 15/16" 1 15/16"VARIES
4 7/8" AT 3 3/4" PARTITION
6" AT 4 7/8" PARTITION
6 5/8" AT 5 1/2" PARTITION
6 3/4" AT 5 5/8" PARTITION
7 1/4" AT 6 1/8" PARTITION
8 1/4" AT 7 1/8" PARTITION
8 3/8" AT 7 5/8" PARTITION
8 3/4" AT 7 5/8" PARTITION
9" AT 7 7/8" PARTITION
9 5/8" AT 8 1/2" PARTITION
9 3/4" AT 8 5/8" PARTITION
1/2" 1/2"
1/2" AT 1/4" GLASS7/8" AT 5/8" GLASS
2"
1"
1 15/16"1 15/16" VARIES
4 7/8" AT 3 3/4" PARTITION
6" AT 4 7/8" PARTITION
6 5/8" AT 5 1/2" PARTITION
6 3/4" AT 5 5/8" PARTITION
7 1/4" AT 6 1/8" PARTITION
8 1/4" AT 7 1/8" PARTITION
8 3/8" AT 7 5/8" PARTITION
8 3/4" AT 7 5/8" PARTITION
9" AT 7 7/8" PARTITION
9 5/8" AT 8 1/2" PARTITION
9 3/4" AT 8 5/8" PARTITION
1/2"1/2"
1/2" AT 1/4" GLASS
7/8" AT 5/8" GLASS
2"3/
4"
1"
1 15
/16"
1 15
/16"
VA
RIE
S
4 7/
8" A
T 3
3/4
" P
AR
TIT
ION
6" A
T 4
7/8
" P
AR
TIT
ION
6 5/
8" A
T 5
1/2
" P
AR
TIT
ION
6 3/
4" A
T 5
5/8
" P
AR
TIT
ION
7 1/
4" A
T 6
1/8
" P
AR
TIT
ION
8 1/
4" A
T 7
1/8
" P
AR
TIT
ION
8 3/
8" A
T 7
5/8
" P
AR
TIT
ION
8 3/
4" A
T 7
5/8
" P
AR
TIT
ION
9" A
T 7
7/8
" P
AR
TIT
ION
9 5/
8" A
T 8
1/2
" P
AR
TIT
ION
9 3/
4" A
T 8
5/8
" P
AR
TIT
ION
1/2"
1/2"
3/4"
-
1/2" AT 1/4" GLASS7/8" AT 5/8" GLASS
2"
HARDWARE SET 1:
4 HINGES TCA 3786 4 ½ X 4 ½ 26D MC2 DOOR PULLS RM7310 72” TYPE 6HD FASTENING US32D ROCK1 CLOSER 3133 STD, PROVIDE INTEGRAL STOP AL LC1 WALL BUMPER 405KICKPLATE?
HARDWARE SET 2:
4 HINGES TCA 2714 4 ½ x 4 ½ 26D MC1 LOCKSET 70 SG 8205 LNW 5/8” CTE WBS 32D SA1 CYLINDER CORE 7300B MK 15 SA1 ELECTRIC STRIKE 4500C 630 HS
COORDINATE WITH VERTEX STANDARD CARD READER
HARDWARE SET 3:
4 HINGES TCA 2714 4 ½ x 4 ½ 26D MC1 LOCKSET 60 DGI 8256 LNW 1 5/8" CTE WBS 32D SA1 CYLINDER CORE DGI 6300 DO NOT DUPLICATE MK X 3 KEYS 15 SA1 DOOR STOP 446 US26D RO1 COAT HOOK RM821 US32D RO
ALUMINUM MULLION
GLAZING
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NOT FOR CONSTRUCTION
As indicated
4/8
/2019
4:3
5:2
3 P
M
A-760179-18-00
04/08/19
TYPICAL DOOR FRAMETYPES & DETAILS
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
MEP/FP Engineer
24 Hartwell Ave #3AHA Consulting Engineers Inc.
Lexington, MA 02118Tel 781 372 3000
DOOR FRAME TYPES DOOR ABBREVIATIONSDOOR PANEL TYPESWINDOW TYPES
LOCATION DOOR FRAME
HDWR COMMENTSMARK ROOM NAME
OPENING PANEL
TYPE MATLWIDTH HEIGHT TYPE MATL THICK
12082-A CONFERENCE ROOM 3' - 0" 8' - 10" F EXISTING 1 3/4" A ALUMINUM 1 USE SALVAGED WOOD CONFERENCE ROOM DOOR
12083-A CONFERENCE ROOM 3' - 0" 8' - 10" F EXISTING 1 3/4" A ALUMINUM 1 USE SALVAGED WOOD CONFERENCE ROOM DOOR
12002-A CORRIDOR 3' - 0" 7' - 10" F WOOD 1 3/4" C ALUMINUM 2
12001-B OPEN OFFICE 3' - 0" 7' - 0" F WOOD 1 3/4" C ALUMINUM 2
12001-A OPEN OFFICE 3' - 0" 7' - 10" F EXISTING 1 3/4" C ALUMINUM 2 USE SALVAGED WOOD OPEN OFFICE DOOR
12079-A POD 3' - 0" 7' - 10" F WOOD 1 3/4" C ALUMINUM 3
12006-A POD 3' - 0" 7' - 10" F WOOD 1 3/4" C ALUMINUM 3
12007-B POD 3' - 0" 7' - 10" F WOOD 1 3/4" C ALUMINUM 3
SCALE:
SECTION DETAIL
6" = 1'-0"10 GLAZING JAMB
SCALE:
SECTION DETAIL
6" = 1'-0"20 GLAZING HEADER
SCALE:
SECTION DETAIL
6" = 1'-0"11 DOOR AND SIDELITE JAMB
SCALE:
SECTION DETAIL
6" = 1'-0"12 GLAZING BASE MULLION
SCALE:
SECTION DETAIL
6" = 1'-0"14 DOOR HEADER
SCALE:
SECTION DETAIL
6" = 1'-0"13 DOOR HEADER
SCALE:
SECTION DETAIL
6" = 1'-0"22 GLAZED OPENING FRAME HEAD
SCALE:
SECTION DETAIL
6" = 1'-0"21 GLAZED OPENING FRAME SILL
SCALE:
SECTION DETAIL
6" = 1'-0"23 GLAZED OPENING JAMB
DOOR HARDWARE
Issuance Schedule
Number Date Description
SCALE:
SECTION DETAIL
6" = 1'-0"24 CORNER MULLION
PENDENT SPRINKLER CONNECTION (CONCEALED)
FIRE PROTECTION LEGEND
EXISTING SPRINKLER HEAD TO BE REMOVED
EXISTING PENDENT SPRINKLER HEAD TO REMAIN
RISER PIPE (THRU FLOOR OR CEILING)
CONCEALED PENDENT SPRINKLER HEAD
LIGHT DASHED LINE INDICATES EXISTING PIPE TO REMAIN
WET SPRINKLER PIPE
REMOVE EXISTING
CONNECT TO EXISTINGCTE
ETR
RE
WS
LFPC LIMIT OF FIRE PROTECTION CONTRACT
NOT IN FIRE PROTECTION CONTRACTNIFPC
WS
FIRE PROTECTION GENERAL NOTES
CTE
I. GENERAL
A. GENERAL: THE SCOPE OF WORK CONSISTS OF FURNISHING ALL LABOR AND MATERIALS
NECESSARY TO COMPLETELY INSTALL THE APPARATUS AND EQUIPMENT READY FOR CONTINUOUS
OPERATION OF THE PROPOSED FIRE PROTECTION SYSTEM AS SHOWN IN THE PROPOSED
CONSTRUCTION DOCUMENTS HERIN.
B. SHOP DRAWINGS: SHOP DRAWINGS OF ALL SPECIFIED EQUIPMENT AND APPARATUS SHALL BE
SUBMITTED TO THE ARCHITECT FOR APPROVAL.
C. CODES: ALL EQUIPMENT AND MATERIALS FURNISHED UNDER THE FIRE PROTECTION
SUB-CONTRACT AND LABOR AND TESTING PERFORMED HEREIN SHALL BE IN COMPLETE
ACCORDANCE WITH THE MASSACHUSETTS STATE BUILDING CODE, LOCAL ORDINANCES AND
REGULATIONS OF THE CITY OF BOSTON, NATIONAL FIRE PROTECTION ASSOCIATION AND INSURANCE
REGULATIONS AND REQUIREMENTS GOVERNING SUCH WORK.
D. PERMITS: ANY AND ALL PERMITS REQUIRED FOR INSTALLATION OF ANY MATERIAL SHALL BE
OBTAINED AS PART OF THE WORK OF THE SPECIFICATION INCLUDING ALL FEES OR EXPENSES
INCURRED.
E. INSTRUCTIONS: DURING THE ASSEMBLY AND INSTALLATION OF ALL FIRE PROTECTION SYSTEMS,
THE OWNER'S OPERATING PERSONNEL SHALL BE INSTRUCTED REGARDING ITS OPERATION AND
MAINTENANCE. AN INSTRUCTION PERIOD SHALL BE PROVIDED AFTER COMPLETION OF PROJECT.
OPERATION AND MAINTENANCE MANUALS SHALL BE REQUIRED.
F. GUARANTEE: ALL MATERIALS AND EQUIPMENT FURNISHED AND INSTALLED SHALL BE GUARANTEED
IN WRITING FOR ONE (1) YEAR FROM THE DATE OF ACCEPTANCE OF THE BUILDING BY THE OWNER.
G. RECORD DRAWINGS: THE FIRE PROTECTION SUBCONTRACTOR SHALL MAINTAIN AT THE JOB, AT
ALL TIMES, A COMPLETE AND SEPARATE SET OF BLACKLINE PRINTS OF THE FIRE PROTECTION
DRAWINGS OF HIS TRADE ON WHICH HE SHALL MARK CLEARLY, NEATLY, ACCURATELY AND
PROMPTLY AS THE WORK PROGRESSES. TWO CAD DISKS, AUTOCAD 2013 OR COMPATIBLE SYSTEM,
AS WELL AS MYLAR REPRODUCIBLE "AS-BUILTS" SHALL BE FURNISHED BY THE FIRE PROTECTION
SUBCONTRACTOR AT THE JOB COMPLETION. THE FIRE PROTECTION CONTRACTOR'S DESIGN
ENGINEER SHALL CERTIFY THAT THE COMPLETED INSTALLATION COMPLIES WITH ALL APPLICABLE
CODES AND UNDERWRITERS' REQUIREMENTS.
H. INSPECTION: ALL WORK SHALL BE SUBJECT TO THE INSPECTION OF THE OWNER, THE ARCHITECT
AND SUCH OTHER INSPECTORS HAVING JURISDICTION. A PROPERLY EXECUTED CERTIFICATE OF
INSPECTION SHALL BE PROVIDED.
I. EXAMINATION OF SITE: THE FIRE PROTECTION SUBCONTRACTOR, BEFORE SUBMITTING PRICES OR
BEGINNING WORK, SHALL THOROUGHLY EXAMINE THE SITE AND CONTRACT DOCUMENTS. NO CLAIM
FOR EXTRA COMPENSATION WILL BE RECOGNIZED IF DIFFICULTIES WHICH AN EXAMINATION OF SITE
CONDITIONS AND CONTRACT DOCUMENTS PRIOR TO EXECUTING CONTRACT WOULD HAVE REVEALED.
J. COORDINATION: COORDINATE ALL WORK INSTALLED UNDER THIS SPECIFICATION WITH THAT OF
ALL OTHER TRADES.
K. PROTECTION OF PROPERTY: PROTECT ALL NEW AND EXISTING WORK BEFORE, DURING AND AFTER
INSTALLATION.
L. TESTS: HE FIRE PROTECTION SUBCONTRACTOR SHALL PERFORM ALL TESTS AT THE COMPLETION
OF THE WORK AND THE RESULTS FURNISHED TO THE OWNER AND ARCHITECT IN WRITING.
M. CERTIFICATES OF APPROVAL: UPON COMPLETION OF ALL WORK, THE FIRE PROTECTION
SUBCONTRACTOR SHALL FURNISH, IN DUPLICATE, CERTIFICATES OF INSPECTIONS FROM ALL
INSPECTORS AND AUTHORITIES HAVING JURISDICTION, NOTARIZED LETTERS FROM THE
MANUFACTURERS STATING THAT AUTHORIZED FACTORY ENGINEERS HAVE INSPECTED AND TESTED
THE INSTALLATION OF THEIR RESPECTIVE SYSTEMS AND FOUND SAME TO BE IN PERFECT OPERATING
CONDITION.
N. CONTRACT DRAWINGS: THE CONTRACT DRAWINGS ARE DIAGRAMMATIC AND INDICATE ONLY THE
GENERAL ARRANGEMENTS OF WORK. IT IS NOT THE INTENT OF THESE DRAWINGS TO SHOW EVERY
PIPE, RISE, DROP, ELBOW, ETC. ANY ADDITIONAL WORK NOT SHOWN AND REQUIRED TO INSTALL THE
FIRE PROTECTION SYSTEMS SHALL BE INCLUDED AS PART OF THIS CONTRACT.
O. REMOVAL WORK: PARTICULAR CARE SHALL BE TAKEN TO AVOID CREATING HAZARDS ON THE SITE
OR CAUSING DISRUPTION OF SERVICE IN THE BUILDING. ALL EXISTING EQUIPMENT TO BE REMOVED
SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. ALL EXISTING EQUIPMENT TO BE TURNED
OVER TO THE OWNER SHALL BE PRESENTED TO THE OWNER IN GOOD CONDITION AT A LOCATION
DESIGNATED BY THE OWNER. ALL OTHER EQUIPMENT SHALL BE REMOVED FROM THE PREMISES.
REMOVE ALL ABANDONED PIPING AND EQUIPMENT NOT BUILT INTO BUILDING CONSTRUCTION. WHERE
CEILING OR WALLS ARE REMOVED, ALL ABANDONED PIPING SHALL BE REMOVED AND ENDS OF LIVE
SERVICES CAPPED. ABANDONED ELEMENTS BUILT INTO WALLS OR LOCATED ABOVE EXISTING
INACCESSIBLE CEILINGS SHALL REMAIN AND ENDS CAPPED AND MARKED ABANDONED.
P. CONTINUITY OF SERVICES: SERVICES SHALL BE MAINTAINED IN ALL AREAS WHICH WILL BE
OCCUPIED DURING THE CONSTRUCTION PERIOD. IF AN INTERRUPTION OF SERVICE BECOMES
NECESSARY, SUCH SHALL BE MADE ONLY UPON CONSENT OF THE OWNER AT A TIME OUTSIDE
NORMAL WORKING HOURS AS HE SHALL DESIGNATE. REFER TO THE OVERALL SCHEDULING OF THE
WORK OF THE PROJECT. SCHEDULE WORK TO CONFORM TO THIS SCHEDULE AND INSTALL WORK TO
NOT DELAY NOR INTERFERE WITH THE PROGRESS OF THE PROJECT.
Q. SEISMIC RESTRAINTS: INSTALLATION OF FIRE PROTECTION EQUIPMENT, ACCESSORIES AND
COMPONENTS SHALL BE IN ACCORDANCE WITH THE SEISMIC REQUIREMENTS IDENTIFIED IN THE
MASSACHUSETTS STATE BUILDING CODE, NINTH (9TH EDITION).
II. SCOPE
A. THE WORK OF THIS SECTION CONSISTS OF ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED TO
PROVIDE ALL FIRE PROTECTION WORK COMPLETE, IN PLACE, AS SHOWN ON THE DRAWINGS,
SPECIFIED HEREIN AND AS NECESSARY FOR A PROPER INSTALLATION.
B. THE EXTENT OF THE FIRE PROTECTION SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING:
1. ALTERATIONS, ADDITIONS AND/OR REMOVAL OF EXISTING AUTOMATIC WET PIPE SPRINKLER OR
COMBINATION SPRINKLER AND STANDPIPE SYSTEM WITHIN THE RENOVATED AREAS IN ORDER TO
CONFORM TO NEW SPACE REQUIREMENTS.
2. FIRE PUMP FLOW TESTING.
3. HYDRAULIC CALCULATIONS.
4. SUBMITTALS AND ACCEPTANCE TESTING.
III. RELATED WORK
A. THE FOLLOWING EQUIPMENT ITEMS AND WORK SHALL NOT BE THE RESPONSIBILITY OF THIS
CONTRACTOR:
1. CUTTING AND PATCHING
2. TEMPORARY WATER, HEAT, FIRE PROTECTION AND TOILET FACILITIES
3. TEMPORARY POWER AND LIGHTING
4. FLASHING AND CAULKING
5. FINISH PAINTING
6. HEATING, VENTILATING AND AIR CONDITIONING
7. PLUMBING
8. ELECTRICAL POWER AND WIRING
9. FIRE EXTINGUISHERS AND CABINETS
10. INSTALLATION OF ACCESS PANELS
IV. MATERIALS
A. PIPE AND FITTINGS SHALL BE IN ACCORDANCE WITH THE FOLLOWING:
TYPE A: SCHEDULE 40 BLACK STEEL PIPE WITH BLACK CAST IRON SCREWED SPRINKLER FITTINGS
SUITABLE FOR 175 PSI WORKING WATER PRESSURE FOR PIPE SIZES 2" AND BELOW.
TYPE B: SCHEDULE 10 WELDED AND SEAMLESS STEEL PIPE IN ACCORDANCE WITH ASTM 135 JOINED
WITH GROOVE FITTINGS AND COUPLINGS APPROVED FOR SERVICE THE GROOVES ROLLED ON THE
PIPE BY AN APPROVED GROOVE ROLLING MACHINE. MINIMUM WALL THICKNESS SHALL BE SCHEDULE
10 FOR SIZES 2-1/2" TO 6" PIPE. FITTINGS AND COUPLINGS SHALL BE DESIGNED SPECIFICALLY FOR
USE IN GROOVED PIPING SYSTEMS AND SUITABLE FOR 175 PSI MINIMUM WORKING PRESSURE.
FITTINGS, COUPLINGS AND GASKETS SHALL BE OF THE SAME MANUFACTURER.
PIPE AND FITTINGS SHALL BE IN ACCORDANCE WITH THE FOLLOWING:
1. TYPE A & B FOR SPRINKLER SYSTEMS
2. TYPE A & B FOR SPRINKLER TEST DRAIN
B. PIPE SLEEVES, HANGERS AND SUPPORTS
1. HANGERS FOR PIPING OF SIZES 4 INCHES AND SMALLER SHALL BE CARPENTER & PATERSON
FIGURE NO. 800 ADJUSTABLE SWIVEL RING, CRANE COMPANY, GRINNELL COMPANY OR
APPROVED EQUAL, BLACK STEEL AND HANGER RODS WITH MACHINE THREADS. ALL HANGERS
SHALL BE UL/FM APPROVED.
2. PIPE SLEEVES SHALL BE INSTALLED AND PROPERLY SECURED AT ALL POINTS WHERE PIPES
PASS THROUGH MASONRY, CONCRETE OR WOOD. PIPE SLEEVES SHALL BE OF SUFFICIENT
DIAMETER TO PROVIDE APPROXIMATELY 1/4 INCH CLEARANCE. PIPE SLEEVES THROUGH
MASONRY PARTITIONS AND FLOORS SHALL BE SCHEDULE 40 GALVANIZED PIPE. WALL SLEEVES
SHALL HAVE CHROMIUM-PLATED ESCUTCHEONS WITH SET SCREWS OR CLIPS FOR FIRMLY
HOLDING IN PLACE. SLEEVES THROUGH WALLS SHALL END FLUSH WITH SURFACE OF WALLS.
SLEEVES IN FLOORS SHALL EXTEND ONE INCH ABOVE THE FLOOR AND AFTER INSTALLATION
OF PIPING SHALL BE PACKED AND MADE WATER TIGHT. PROVIDE CORE DRILLING. CORE
OPENINGS SHALL HAVE LINK-SEAL FIRE RATED PENETRATION CLOSURES. SLEEVES IN
EXTERIOR WALLS SHALL HAVE WATER STOP PLATES, SHALL END FLUSH WITH THE SURFACE OF
THE WALLS AND SHALL HAVE LINK-SEAL PENETRATION CLOSURES.
3. WHERE PIPES PENETRATE FIRE RATED FLOORS AND PARTITIONS, THE OPENINGS SHALL BE
PACKED WITH A MATERIAL WHICH WILL MAINTAIN THE INTEGRITY OF THE FIRE RATING.
C. PIPE IDENTIFICATION
1. ALL FIRE PROTECTION PIPING SHALL BE LABELED AT EACH BRANCH, AT EACH PASSAGE
THROUGH WALL AND AT INTERVALS OF NOT MORE THAN 20 FEET WITH SEMI-RIGID SETMARK
PIPE MARKERS WITH ARROWS INDICATING THE DIRECTION OF FLOW.
D. SPRINKLER HEADS
1. SPRINKLER HEADS, IN GENERAL, SHALL BE AUTOMATIC CLOSED TYPE WITH TEMPERATURE
RATINGS TO SUIT INSTALLED CONDITIONS. SPRINKLER HEADS SHALL BE LOCATED IN THE
CENTER OF THE CEILING TILES. WHEN THE CEILING TILE IS DIVIDED INTO SECTIONS BY
GROOVED DEPRESSIONS, THE SPRINKLER HEAD SHALL BE LOCATED IN THE CENTER OF ONE
OF THE PANELS.
2. SPRINKLER HEADS IN AREAS TO BE FINISHED WITH CEILINGS SHALL BE CONCEALED PENDENT
TYPE WITH WHITE COVER PLATE. SPRINKLER HEADS IN UNFINISHED SPACES SHALL BE
NATURAL BRONZE PENDENT OR UPRIGHT.
3. SPARE HEADS, CABINET AND WRENCH SHALL BE PROVIDED IN ACCORDANCE WITH NFPA-13.
4. ALL SPRINKLERS IN NEW LIGHT AND ORDINARY HAZARD OCCUPANCIES SHALL BE QUICK
RESPONSE TYPE. IN EXISTING BUILDINGS, THE THERMAL SENSITIVITY OF NEW SPRINKLER
HEADS SHALL MATCH THAT OF THE EXISTING SPRINKLERS UNLESS ALL SPRINKLERS IN THE
SCOPE OF WORK AREA ARE REPLACED WITH NEW QUICK RESPONSE TYPE SPRINKLER HEADS.
5. ALL NEW SPRINKLERS SHALL BE INSTALLED ON MINIMUM 1" OUTLETS. FOR EXISTING
SPRINKLER SYSTEMS THAT REQUIRE RELOCATION OF SPRINKLERS, ANY SPRINKLER OUTLETS
LESS THAN 1" IN SIZE SHALL BE REMOVED AND REPLACED WITH 1" OUTLETS.
CONCEALED PENDENT SPRINKLER
WHITE COVER PLATE
CEILING
1" X 1/2" REDUCER
NO SCALE
TEE IN SPRINKLER BRANCH LINE
1" MINIMUM DROP
UNDERSIDE OF FLOOR/ROOF ABOVE
FIRE PROTECTION SPECIFICATIONS
1. FOLLOW THE LATEST REQUIREMENTS OF NFPA, THE MASSACHUSETTS STATE
BUILDING CODE, INSURANCE UNDERWRITERS', THOSE OF BOSTON
MASSACHUSETTS AND THOSE OF ANY OTHER CITY, STATE, OR FEDERAL AGENCY
HAVING JURISDICTION OVER THIS PROJECT.
2. PLANS INDICATE GENERAL SCOPE OF WORK. REFER TO CONTRACT
DOCUMENTS AND SPECIFICATIONS FOR DETAILS ON ENTIRE SCOPE OF WORK.
LOCATIONS OF SPRINKLER OUTLETS, BRANCH LINES AND FEED MAINS ARE
DIAGRAMMATIC. THE DRAWINGS ARE NOT MEANT TO SHOW ALL OFFSETS AND
PIPING ELEVATION CHANGES. THE CONTRACTOR SHALL VERIFY ALL NEEDED
OFFSETS AND PIPE ELEVATIONS TO INSTALL THE PROPOSED SPRINKLER SYSTEM.
3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THE
WORK WITH THAT OF ALL OTHER TRADES. THE INSTALLING CONTRACTOR SHALL
COORDINATE ALL WORK TO THE EXISTING AND/OR NEW FIELD CONDITIONS.
4. ANY INTERFERENCE SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S
REPRESENTATIVE AND SHALL BE RESOLVED PRIOR TO THE INSTALLATION OF
WORK. ANY SIZES OF NEW PIPING SHOWN ON THE PLAN ARE MEANT TO BE A
GUIDE FOR ESTIMATING THE WORK.
5. THE CONTRACTOR SHALL PERFORM HYDRAULIC CALCULATIONS TO VERIFY PIPE
SIZES ARE ADEQUATE TO PROVIDE THE NECESSARY SYSTEM DEMANDS.
6. PROVIDE A NEW FIRE PUMP FLOW TEST AS REQUIRED BY THE AUTHORITY
HAVING JURISDICTION AND NFPA. USE THE RESULTS OF THE NEW FIRE PUMP
FLOW TEST TO HYDRAULICALLY DESIGN THE SPRINKLER SYSTEMS WITHIN THE
BUILDING.
7. DESIGN CRITERIA
A. SPRINKLER SYSTEMS SHALL BE HYDRAULICALLY DESIGNED AND
CALCULATED BY THE FIRE PROTECTION CONTRACTOR. THE FIRE
PROTECTION CONTRACTOR SHALL SUBMIT ALL REQUIRED HYDRAULIC
CALCULATIONS TO PROVE THE HYDRAULICALLY MOST REMOTE AREAS ARE
BEING PROTECTED PER SYSTEM AND OCCUPANCY HAZARD. FABRICATION
DRAWINGS AND HYDRAULIC CALCULATIONS SHALL BE HAVING JURISDICTION
AND INSURANCE SUBMITTED TO THE AUTHORITY SUBMITTING TO THE
ARCHITECT FOR REVIEW. UNDERWRITERS (IF REQUIRED) PRIOR TO
FABRICATION DRAWINGS AND HYDRAULIC CALCULATIONS SHALL BEAR THE
SEAL OF PROFESSIONAL FIRE PROTECTION REGISTRATION OF A QUALIFIED
REGISTERED ENGINEER. MAINTAIN A MINIMUM OF 10 PSI CUSHION BETWEEN
REQUIRED PRESSURE ALL UNDERWRITERS' AND CODE AND AVAILABLE
PRESSURE. COMPLY WITH AUTHORITIES REQUIREMENTS INCLUDING
MAXIMUM WATER FLOW VELOCITY IN THE FIRE PROTECTION SYSTEM.
B. AUTOMATIC SPRINKLER SYSTEMS IN AREAS OF LIGHT HAZARD OCCUPANCY
SHALL BE DESIGNED WITH A MINIMUM DESIGN DENSITY OF .10 GPM PER
SQUARE FOOT OVER THE HYDRAULICALLY MOST REMOTE 1500 SQUARE
FEET. MAXIMUM PROTECTION AREA PER SPRINKLER HEAD SHALL BE 225
SQUARE FEET FOR UPRIGHT AND PENDENT SPRINKLER HEADS, AND 196
FEET FOR SIDEWALL SPRINKLER HEADS. PROVIDE A 100 GPM HOSE
ALLOWANCE. LIGHT HAZARD AREAS INCLUDE OPEN OFFICE SPACES,
OFFICES, CONFERENCE ROOMS, CORRIDORS, PODS AND SIMILAR ROOMS.
C. AUTOMATIC SPRINKLER SYSTEMS IN AREAS OF ORDINARY HAZARD GROUP I
OCCUPANCY SHALL BE DESIGNED WITH A MINIMUM DESIGN DENSITY OF .15
GPM PER SQUARE FOOT OVER THE HYDRAULICALLY MOST REMOTE 1500
SQUARE FEET. MAXIMUM PROTECTION AREA PER SPRINKLER HEAD SHALL
BE 130 SQUARE FEET. PROVIDE A 250 GPM HOSE ALLOWANCE. ORDINARY
HAZARD GROUP I AREAS INCLUDE STORAGE ROOMS AND SIMILAR ROOMS.
planninarchitectureinteriors
g
Scale: Date Issued:
Project Number:
Isgenuity LLC321 Summer Street, Suite 401Boston, MA 02210Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
AHA Consulting Engineers24 Hartwell Avenue, 3rd floorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
12" = 1'-0"
4/8
/2019
2:4
9:4
2 P
M
FP0.00179.02.00
04/08/2019
FIRE PROTECTION LEGEND,NOTES, & DETAIL
VERTEX
PHARMACEUTICALS12TH FLOOR CALL CENTER
ISSUED FOR BIDNOT FOR CONSTRUCTION
Issuance Schedule
Number Date Description
TENANTEXHAUST
1210
MEN'SRESTROOM
1208
SHOWER
1211
b1 b1.4 b2 b3 b3.2 b3.5 b4
bF
bE.3
bE
bD.9
bD
ETR
ETR
ETRMATCHLINE
NIF
AC
LF
AC
NIF
AC
LF
AC
MATCHLINE
NIFAC
LFAC
ETR ETR ETR ETR ETR
ETR
CTE
ETR
ETR
ETRETRETRETR
ETRETRETRETR
ETR ETRETR
ETRETRETRETR
ETR ETRETR ETR
ETRETRETRETR
ETR
ETRETRETRETR
ETRETRETRETR
ETR
ETR
ETR
ETRETR
ETRETRETR
ETRETR
CTE
planninarchitectureinteriors
g
Scale: Date Issued:
Project Number:
Isgenuity LLC321 Summer Street, Suite 401Boston, MA 02210Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
AHA Consulting Engineers24 Hartwell Avenue, 3rd floorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
1/4" = 1'-0"
4/8
/2019
2:4
9:4
3 P
M
FP1.12A179.02.00
04/08/2019
FIRE PROTECTION 12THFLOOR NORTH PLAN
VERTEX
PHARMACEUTICALS12TH FLOOR CALL CENTER
ISSUED FOR BIDNOT FOR CONSTRUCTION
12TH FLOOR RENOVATION AREA SPRINKLER HEAD COUNT:
REMOVED: (-4)SPRINKLER HEADS ADDED: (+2)NET SPRINKLER HEADS: (-2)
Issuance Schedule
Number Date Description
b1 b1.4 b2
bA.8
bB
bB.1
bB.3
bC
bC.3
bA
ETR
ETR
ETR
ETR
ETR
ETR
MATCHLINE NIF
AC
LF
AC
NIF
AC
LF
AC
MATCHLINE
ETR ETR ETR
ETR
ETR ETR
ETR ETR
ETR ETR ETR ETR
ETR
ETR
ETR
ETR
ETR
ETRRE RERERE
planninarchitectureinteriors
g
Scale: Date Issued:
Project Number:
Isgenuity LLC321 Summer Street, Suite 401Boston, MA 02210Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
AHA Consulting Engineers24 Hartwell Avenue, 3rd floorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
1/4" = 1'-0"
4/8
/2019
2:4
9:4
4 P
M
FP1.12B179.02.00
04/08/2019
FIRE PROTECTION 12THFLOOR SOUTH PLAN
VERTEX
PHARMACEUTICALS12TH FLOOR CALL CENTER
ISSUED FOR BIDNOT FOR CONSTRUCTION
12TH FLOOR RENOVATION AREA SPRINKLER HEAD COUNT:
REMOVED: (-4)SPRINKLER HEADS ADDED: (+2)NET SPRINKLER HEADS: (-2)
Issuance Schedule
Number Date Description
MECHANICAL GENERAL NOTES
MECHANICAL DUCTWORK NOTES
MECHANICAL PIPING NOTESMECHANICAL DEMOLITION NOTES
1. MINIMUM SIZE OF HOT WATER SUPPLY, HOT WATER RETURN AND CONDENSATE DRAIN PIPING SHALL BE 3/4" UNLESS OTHERWISE NOTED.
2. MINIMUM SIZE OF STEAM CONDENSATE RETURN PIPING SHALL BE 1" UNLESS OTHERWISE NOTED.
3. PROVIDE ISOLATION VALVES IN SUPPLY AND RETURN PIPING ON EACH FLOOR, AND IN BRANCH PIPING SERVING MORE THAN ONE PIECE OF EQUIPMENT.
4. PROVIDE SHUTOFF VALVES IN THE SUPPLY AND RETURN PIPING TO ALL EQUIPMENT TO ALLOW FOR SERVICING. UNIONS AND FLANGES SHALL BE ARRANGED SUCH THAT EQUIPMENT CAN BE SERVICED WITHOUT CUTTING AND MINIMAL DISRUPTION OF PIPING SERVING THE EQUIPMENT.
5. PIPING AT PUMPS AND EQUIPMENT SHALL BE SUPPORTED SO THAT NO PIPING OR ACCESSORY LOAD IS CARRIED BY THE PUMP OR EQUIPMENT.
6. ALL PIPING ABOVE GRADE SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. PIPING HUNG FROM JOISTS SHALL BE HUNG FROM THE TOP CHORDS OF THE JOISTS.
7. INSULATE ALL CHILLED WATER PIPING. ALL EXPOSED INSULATED PIPING BELOW 10'-0" AFF SHALL BE JACKETED. ALL EXTERIOR COOLING WATER PIPING SHALL BE INSULATED & JACKETED OVER ELECTRIC HEAT TRACING UNLESS NOTED OTHERWISE OR SYSTEM IS PROVIDED WITH PROPYLENE OR ETHYLENE GLYCOL. REFER TO SPECIFICATIONS FOR INSULATION & JACKETING REQUIREMENTS.
8. WHERE MAXIMUM OPERATING PRESSURE IS GREATER THAN 150 PSIG INANY SYSTEM, THE HVAC CONTRACTOR SHALL FURNISH AND INSTALL PRODUCTS, PIPING, VALVES, FITTINGS AND ACCESSORIES WITH PRESSURE CLASSIFICATIONS THAT ARE SUITABLE FOR SERVICE. IN GENERAL, ALL PRODUCTS, PIPING, VALVES, FITTINGS AND ACCESSORIES BELOW 350 FEET OF THE HIGHEST PIPING POINT MUST HAVE PRESSURE RATINGS OF 300 PSI W.O.G. (WATER, OIL, GAS) OR GREATER. ALL PRODUCTS, PIPING, VALVES, FITTINGS, AND ACCESSORIES BELOW 575 FEET OF THE HIGHEST PIPING POINT MUST HAVE PRESSURE RATINGS OF 500 PSI W.O.G. OR GREATER.
9. EXPANSION IN PIPING SYSTEMS SHALL BE COMPENSATED FOR BY THE US OF U-BENDS, Z-BENDS OR EXPANSION JOINTS AS INDICATED. U-BENDS (LOOPS) AND Z-BENDS SHALL BE COMPLETE WITH PIPE GUIDES AND ANCHORS.
10. PROVIDE AUTOMATIC AIR VENT (WITH DRAIN) AT HIGH POINTS OF ALL RECIRCULATING WATER PIPING SYSTEMS.
11. CONDENSATE FROM ALL COOLING COILS SHALL BE TRAPPED AND ROUTED TO THE NEAREST HUB/FLOOR DRAIN, STORM OR EXTERIOR DRY WELLS. CONDENSATE PIPING SHALL BE INSULATED COPPER. CONDENSATE SHALL BE PUMPED AS REQUIRED.
12. REFRIGERANT PIPING SHALL BE TYPE L OR REFRIGERATION SERVICE COPPER TUBING WITH BRAZED JOINTS. SUCTION PIPING SHALL BE INSULATED WITH 3/4" MANVILLE AEROTUBE II PIPE INSULATION OVER TUBING WITHOUT CUTTING. ALL JOINTS AND SEAMS SHALL BE SEALED WITH ADHESIVE.
13. REFRIGERANT PIPING CARRYING OTHER THAN GROUP A1 OR B1 REFRIGERANTS AND INTERCONNECTING SEPARATE PIECES OF EQUIPMENT AND PASSING VERTICALLY THROUGH FLOORS FROM ONE STORY TO ANOTHER SHALL BE ENCLOSED IN A CODE APPROVED RIGID AND TIGHT CONTINUOUS FIRE RESISTING PIPE DUCT OR SHAFT HAVING NO OPENINGS INTO FLOORS NOT SERVED BY THE REFRIGERATING SYSTEM, AS REQUIRED BY LOCAL CODE AUTHORITIES. THE PIPE DUCT OR SHAFT SHALL BE VENTED TO OUTDOORS.
1. ALL WORK SHALL CONFORM TO THE STATE BUILDING CODES AND ALL OTHER APPLICABLE CODES AND REGULATIONS
2. THE DRAWINGS DEPICT ONLY GENERALLY THE EXISTING CONDITIONS THE CONTRACTOR SHALL MAKE FIELD OBSERVATIONS AND CONFIRM WALL LOCATIONS, DUCTWORK, PIPING AND OTHER UTILITIES ABOVE EXISTING CEILINGS.
3. ALL CONFLICTS AND ITEMS FOR CLARIFICATIONS SHALL BE BROUGHT TO THE ENGINEER/ ARCHITECT'S ATTENTION PRIOR TO WORK IN THE AREA.
4. THE CONTRACTOR IS RESPONSIBLE TO FOLLOW BUILDING MANAGEMENT RULES WITH REGARDS TO TRASH, ELEVATORS, NOISE,SPRINKLERS AND FIRE ALARM.
5. THE CONTRACTOR SHALL MAINTAIN IN OPERATION ALL EXISTING UTILITIES DURING CONSTRUCTION.
6. ITEMS IDENTIFIED TO BE SALVAGED SHALL BE STOCKPILED IN AN AREA FORREMOVAL BY THE OWNER. ALL OTHER ITEMS BEING REMOVED SHALL BEDISPOSED OF LEGALLY OFF SITE. ALL ITEMS BEING REMOVED AND NOT REUSED SHALL BE DISPOSED OF AS DIRECTED BY THE OWNER.
7. CAPPING OF ALL SERVICES SHALL BE PERFORMED TO LEAVE EXISTING SERVICES TO OTHER AREAS INTACT AND FUNCTIONAL.
8. ALL DEMOLITION WORK WILL BE SCHEDULED WITH BUILDING MANAGEMENTAND PERFORMED ONLY FOLLOWING APPROVAL.
9. THE CONTRACTOR SHALL INFORM BUILDING MANAGEMENT AND RECEIVESCHEDULE APPROVAL FOR ANY REQUIRED UTILITY SHUTDOWN.
10. WHERE EQUIPMENT IS SHOWN TO BE REMOVED, THE EQUIPMENT SHALL BEDELIVERED TO BUILDING MANAGEMENT FOR STORAGE OR PROPERLY DISPOSED OF AS DIRECTED BY BUILDING MANAGEMENT.
11. WHERE EQUIPMENT IS SHOWN OR NOTED AS BEING REMOVED & REPLACEDAFTER WALL/CEILING STRUCTURAL OR ARCHITECTURAL WORK IS PERFORMED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER, SAFE STORAGE OF SUCH EQUIPMENT.
12. ANY DUCTWORK SHOWN TO BE REMOVED SHALL INCLUDE REMOVE OF ALLASSOCIATED DUCTWORK, FLEXIBLE CONNECTIONS, DIFFUSERS, HANGERS,INSULATION, ETC.
13. ANY PIPING SHOWN TO BE REMOVED WILL BE REMOVED TO THE POINT INDICATED ON THE DRAWING OR TO THE ACTIVE MAIN AND VALVED AND CAPPED. PIPING REMOVAL SHALL INCLUDE ALL HANGERS, VALVES, INSULATION, ETC.
14. EXISTING DUCTWORK SHALL BE CAPPED AND SEALED AIR TIGHT, EXCEPT WHERE UTILIZED FOR NEW BRANCH DUCTWORK.
15. THERMOSTATS ARE TO BE RELOCATED AS SHOWN ON NEW WORK DRAWING.
16. REMOVE AND CLEAN ALL SUPPLY, RETURN & EXHAUST DIFFUSERS & GRILLES. RE-INSTALL OR SAVE FOR RELOCATION AS SHOWN ON NEW WORK PLAN.
17. ALL DIFFUSERS TO BE TIED TO UNDERSIDE OF STRUCTURE TO FACILITATEREMOVAL OF EXISTING CEILING AND MAINTAIN DIFFUSER CONNECTION TODUCTWORK WHERE APPLICABLE. DIFFUSERS SHALL BE REPLACED INTO NEW CEILING GRID AS SHOWN ON THE NEW WORK DRAWING. ADDITIONAL LENGTH OF FLEX MAY BE REQUIRED FOR DIFFUSERS.
18. CONTRACTOR SHOULD SURVEY EXISTING CONDITIONS AND INFORM ENGINEER OF ANY DEVIATIONS PRIOR TO CONSTRUCTION.
1. ALL DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF SMACNA STANDARDS.
2. PROVIDE VOLUME DAMPERS AT ALL LOW PRESSURE SUPPLY, RETURN AND EXHAUST DUCTWORK BRANCH TAKE-OFFS.
3. SUPPLY AND RETURN DUCT MAINS FROM AIR HANDLING EQUIPMENT SHALL BE INTERNALLY LINED WITH 1" ACOUSTICAL LINING A MINIMUM OF 10'-0" FROM THE UNIT UNLESS OTHERWISE NOTED. ALL DUCTWORK DIMENSIONS INDICATED ARE CLEAR INSIDE DIMENSIONS. ALL INTERNAL ACOUSTICAL DUCT LINING SHALL HAVE AIR SURFACE COATED WITH ACRYLIC COATING FORMULATED WITH IMMOBILIZED EPA REGISTERED ANTI-MICROBIAL AGENT PROVEN TO RESIST MICROBIAL GROWTH AS DETERMINED BY ASTM G21 AND G22.
4. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR FINAL LOCATIONS OF DIFFUSERS, REGISTERS AND GRILLES.
5. FIRE DAMPERS AND ACCESS PANELS SHALL BE INSTALLED AT ALL FIRE RATED ASSEMBLIES AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR ASSEMBLY LOCATIONS. WHERE DUCTS PENETRATE WALLS THAT CARRY BOTH FIRE AND SMOKE RATINGS, THE DAMPER SHALL BE COMBINATION FIRE/ SMOKE DAMPERS. COMBINATION FIRE/ SMOKE DAMPERS SHALL BE PROVIDED WITH POWER IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS. THE MECHANICAL SUBCONTRACTOR SHALL COORDINATE COMBINATION FIRE/ SMOKE DAMPER POWER REQUIREMENTS WITH THE ELECTRICAL SUBCONTRACTOR.
6. PROVIDE FIRE DAMPERS AT ALL TRANSFER DUCTS IN FIRE RATED PARTITIONS.
7. EACH SUPPLY DIFFUSER/REGISTER RUNOUT SHALL BE PROVIDED WITH A VOLUME DAMPER. REFER TO CEILING DIFFUSER BRANCH TAKE-OFF DETAIL FOR ADDITIONAL INFORMATION.
8. ALL VOLUME DAMPERS LOCATED ABOVE HARD NON-ACCESSIBLE CEILINGS SHALL BE PROVIDED WITH A YOUNG REGULATOR VOLUME DAMPER FOR REMOTE BALANCING.
9. RUNOUT SIZES TO DIFFUSERS/REGISTERS SHALL MATCH INLET SIZE NOTED IN THE DIFFUSER REGISTER/ GRILLE SCHEDULE OR TAG UNLESS SHOWN OTHERWISE ON THE FLOOR PLANS.
10. RUNOUT SIZES TO TERMINAL UNITS SHALL BE 2" LARGER THAN INLET SIZE UNLESS OTHERWISE NOTED OR SHOWN ON THE FLOOR PLANS.
11. ALL FANS SUPPLYING MORE THAN 2,000 CFM OF AIR TO ANY SPACE SHALL BE INSTALLED WITH A SMOKE DETECTOR IN THE [SUPPLY] [RETURN] DUCTWORK. DUCT SMOKE DETECTORS SHALL BE INSTALLED IN THE [SUPPLY] [RETURN] AIR PATH OF AIR DISTRIBUTION SYSTEMS UTILIZING A COMMON SUPPLY AND/OR RETURN AIR PLENUM WITH A COMBINED DESIGN CAPACITY GREATER THAN 2,000 CFM. THE SMOKE DETECTOR SHALL BE WIRED TO STOP THE FAN UPON DETECTION OF SMOKE, AND SIGNAL THE BUILDING FIRE ALARM CONTROL PANEL. THE SMOKE DETECTOR SHALL BE FURNISHED BY ELECTRICAL CONTRACTOR, MOUNTED IN THE DUCT BY MECHANICAL CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR.
12. LOCATIONS OF LOUVERS SHOWN ON THE PLANS ARE APPROXIMATE. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATION.
13. FLEXIBLE DUCT LENGTH SHALL NOT EXCEED 6'-0" IN LENGTH. FLEXIBLE DUCTWORK SHALL BE INSTALLED AS STRAIGHT AS POSSIBLE AND SHALL BE ROUTED AND SUPPORTED WITHOUT FORMING CRIMPS OR OTHER AIR FLOW RESTRICTIONS. PROVIDE SQUARE TO ROUND ADAPTERS OR BOOTS TO CONNECT TO AIR DEVICES NECK WHEN REQUIRED.
14. GAS FLUE TYPES (U.L. LISTED): FOR ALL CATEGORY I AND DRAFT HOOD EQUIPPED APPLIANCES: TYPE 'B' DOUBLE WALL FLUE. FOR ALL CATEGORY II, III & IV APPLIANCES: SCHEBLER, MODEL 'E-VENT' OR APPROVED EQUAL.
1. ALL HVAC WORK SHALL BE IN ACCORDANCE WITH APPLICABLE FEDERAL,STATE AND LOCAL CODES INCLUDING AMENDMENTS:9TH EDITION STATE BUILDING CODE2015 INTERNATIONAL BUILDING CODE2015 INTERNATIONAL MECHANICAL CODE2015 INTERNATIONAL ENERGY CONSERVATION CODE
2. INDOOR DESIGN CONDITIONS:SUMMER (COOLING): 75ºF, 50% RH, AT 91ºF DB/73ºF WB OUTDOOR.WINTER (HEATING): 72ºF AT 6ºF OUTDOOR.
3. THE HEATING, VENTILATING AND AIR CONDITIONING (HVAC) CONTRACTOR SHALL VISIT THE SITE TO DETERMINE ALL PRE-EXISTING CONDITIONS AND WORK NECESSARY PRIOR TO SUBMISSION OF BID PRICE.
4. THE HEATING, VENTILATING AND AIR CONDITIONING (HVAC) CONTRACTOR SHALL BE FAMILIAR WITH ALL CONTRACT DOCUMENTS FOR ALL TRADES AND COORDINATE WITH OTHER CONTRACTORS.
5. DRAWINGS ARE DIAGRAMMATIC ONLY: FINAL ROUTING OF DUCTWORK, PIPING AND EQUIPMENT LOCATIONS SHALL BE DETERMINED IN THE FIELD ADDITIONAL OFFSETS, ELBOWS, ETC., SHALL BE PROVIDED AND INSTALLED WITHOUT ADDITIONAL COST TO THE OWNER.
6. THE HVAC CONTRACTOR SHALL COORDINATE ALL ELECTRICAL AND PLUMBING REQUIREMENTS WITH THE ELECTRICAL AND PLUMBING CONTRACTORS.
7. THE AUTOMATIC TEMPERATURE CONTROL (ATC) CONTRACTOR SHALL COORDINATE THERMOSTAT LOCATIONS WITH THE ARCHITECTURAL FURNITURE PLANS. THERMOSTATS SHALL BE INSTALLED 48" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED.
8. THE HVAC CONTRACTOR SHALL FURNISH AND INSTALL ALL INCIDENTAL ACCESSORIES NECESSARY TO MAKE THE HVAC WORK COMPLETE AND READY FOR OPERATION.
9. ALL HVAC EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
10. DEMOLITION WORK SHALL BE DONE BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR SHALL COORDINATE ALL WORK CONCERNING EXISTING EQUIPMENT AND SYSTEMS REMAINING IN THE BUILDING. ALL UNUSED DUCTS AND PIPES AS A RESULT OF THE DEMOLITION SHALL BE CAPPED, SEALED AND INSULATED.
11. THE HVAC CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE INTEGRITY, CONDITION AND LOCATION OF EXISTING DUCTWORK AND PIPING WHICH IS TO BE REUSED. IF PIPING AND DUCTWORK CANNOT BE REUSED, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ ENGINEER TO DETERMINE THE EXTENT OF REPLACEMENT.
12. FURNISH TO THE GENERAL CONTRACTOR ALL INFORMATION REQUIRED FOR SETTING OF WALL, ROOF AND PARTITION OPENINGS FOR HVAC WORK. THIS INFORMATION SHALL BE FURNISHED IN A TIMELY MANNER SUCH THAT CONSTRUCTION SCHEDULE IS NOT JEOPARDIZED.
13. INFORM AND COORDINATE WITH THE OWNER ALL NECESSARY INTERRUPTIONS TO EXISTING BUILDING SYSTEMS AND SERVICE THAT MAY AFFECT THE NORMAL OPERATION OF OCCUPIED PORTIONS OF THE BUILDING. THE OWNER SHALL BE INFORMED OF ANY INTERRUPTIONS AT LEAST TWO (2) WEEKS IN ADVANCE.
14. INFORM THE OWNER WELL IN ADVANCE OF ANY WORK TO BE UNDERTAKEN IN OCCUPIED AREAS OF THE BUILDING ASSOCIATED WITH THIS PROJECT. CONFORM NOISE LIMITS IN THE PORTIONS OF THE BUILDING WHICH REMAIN OCCUPIED DURING CONSTRUCTION.
15. COORDINATE PHASING REQUIREMENTS FOR THE PROJECT WITH THE GENERAL CONTRACTOR.
16. FIELD MEASURE THE EXACT SIZES AND VERIFY ALL OPENINGS FOR SHAFTS AND LOUVERS PRIOR TO SUBMISSION OF SHOP DRAWINGS AND INSTALLATION.
17. MINIMAL CONTROL POWER HAS BEEN IDENTIFIED ON THE DRAWINGS. IF ANY ADDITIONAL POWER IS REQUIRED BASED ON SYSTEMS DESIGN BY THE CONTROLS CONTRACTOR THE ATC/BAS CONTRACTOR SHALL BE RESPONSIBLE TO SUPPLY THAT POWER.
18. THE HVAC CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL EQUIPMENT,DUCTWORK, PIPING, ETC. TO FIT WITHIN THE SPACE ALLOWED BY THE ARCHITECTURAL AND STRUCTURAL CONDITIONS. CUTTING OR OTHERWISE ALTERING ANY STRUCTURAL MEMBERS SHALL NOT BE PERMITTED WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT.
19. ANY EXISTING WALL, FLOOR, OR CEILING SURFACE THAT IS DISTURBED DURING THE COURSE OF THE HVAC WORK SHALL BE REPAIRED TO MATCH NEW AND/OR EXISTING CONDITIONS.
20. PROVIDE ACCESS PANELS IN NON-ACCESSIBLE CEILINGS AND IN WALL STRUCTURES OF ADEQUATE SIZE TO ALLOW FOR MAINTENANCE, BALANCING AND COMPLETE REPLACEMENT OF EQUIPMENT WITHOUT DISTURBING PERMANENT CONSTRUCTION. ACCESS PANELS IN CEILINGS AND WALLS SHALL BE PROVIDED WHERE SHOWN ON THE PLANS OR NECESSARY TO ACCESS DAMPERS, VALVES, ETC. COORDINATE EXACT LOCATION & SIZES OF ALL ACCESS PANELS WITH THE ARCHITECT DURING THE SHOP DRAWING PROCESS.
21. PORTIONS OF DUCTWORK AND PIPE INSULATION VISIBLE THROUGH AIR DISTRIBUTION DEVICES IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK.
22. ALL PIPE AND DUCT PENETRATIONS OF FIRE AND/OR SMOKE-RATED ASSEMBLIES SHALL BE FIRE-STOPPED AS REQUIRED TO RESTORE THE ASSEMBLY TO ITS ORIGINAL INTEGRITY. FIRE BARRIER PRODUCTS SHALL BE AS MANUFACTURED BY TREMCO, HILTI, 3M OR APPROVED EQUAL.
23. WHERE ABOVE CEILING VOLUMES OR MECHANICAL ROOM/CLOSETS ARE UTILIZED AS A RETURN AIR PLENUM, ALL MATERIALS EXPOSED WITHIN THE PLENUMS SHALL BE NON-COMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 50 AS DETERMINED IN ACCORDANCE WITH ASTM E84.
24. THE HVAC CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL MECHANICAL EQUIPMENT WITH ELECTRICAL DRAWINGS PRIOR TO SUBMITTING SHOP DRAWINGS OR ORDERING EQUIPMENT. EQUIPMENT SHALL BE FURNISHED WIRED FOR THE VOLTAGES SHOWN ON THE ELECTRICAL PLANS.
25. ALL MECHANICAL EQUIPMENT REQUIRING ELECTRICAL POWER SHALL BE INSTALLED WITH DISCONNECT SWITCHES AT EACH PIECE OF EQUIPMENT. COORDINATE SWITCH TYPE WITH EQUIPMENT CHARACTERISTICS, MANUFACTURER'S RECOMMENDATIONS AND THE ELECTRICAL DRAWINGS.
26. ALL REQUIRED CONTROL WIRING (INCLUDING POWER WIRING REQUIRED FOR CONTROL PANELS, DEVICES, ETC. ) NOT SHOWN ON THE ELECTRICAL DRAWINGS SHALL BE INCLUDED AS PART OF THE MECHANICAL WORK.
27. UNLESS NOTED OTHERWISE, TRANSFORMERS, CONTROLS AND CONTROL WIRING REQUIRED FOR ALL MECHANICAL SYSTEMS SHALL BE FURNISHED WITH THE EQUIPMENT IT SERVES AND INSTALLED BY THE MECHANICAL CONTRACTOR. MOTOR STARTERS FOR HVAC EQUIPMENT SHALL BE FURNISHED WITH THE MOTOR OR APPARATUS WHICH IT OPERATES. MOTOR STARTER INSTALLATION SHALL BE BY THE ELECTRICAL CONTRACTOR.
28. ALL EVAPORATORS AND COOLING COILS LOCATED ABOVE THE LOWEST LEVEL FINISHED FLOOR SHALL BE INSTALLED WITH AN AUXILIARY CONDENSATE DRAIN PAN UNDER THE UNIT. PROVIDE AN ELECTRONIC WATER LEVEL DETECTOR WIRED TO SHUTDOWN THE UNIT UPON DETECTION OF WATER IN THE AUXILIARY DRAIN PAN. AS AN ALTERNATE TO THE AUXILIARY CONDENSATE DRAIN PAN, AN ELECTRONIC WATER LEVEL DETECTOR WIRED TO SHUTDOWN THE UNIT UPON DETECTION OF WATER MAY BE INSTALLED IN THE PRIMARY DRAIN LINE, THE OVERFLOW DRAIN LINE OR THE EQUIPMENT-SUPPLIED DRAIN PAN. THE WATER LEVEL DETECTOR SHALL BE LOCATED AT A POINT HIGHER THAN THE PRIMARY DRAIN LINE CONNECTION AND BELOW THE OVERFLOW RIM OF PAN.
MOTORIZED EQUIPMENT (EF, B)
NON-MOTORIZED EQUIPMENT (ET, AS, CV)
DUCTWORK SPECIALTIES
MISCELLANEOUS
SD
12H-1
EQP
#
EQP
#
AH-1
U
L
MD
*E/R/N
H
T
CO
CO2
RETURN/EXHAUST OUTLET
DIFFUSER WITH FLEX DUCT
UNDERCUT DOOR
LOUVERED DOOR
12Ø
24/12
14 x 6
24/12
12Ø
DIFFUSER
HUMIDISTAT
MOTORIZED DAMPER
EXISTING DUCT TO BE REMOVED
EXISTING DUCT TO REMAIN
RECTANGULAR DUCT
SOUND ATTENUATOR
ACOUSTICAL DUCT LINING
RETURN/EXHAUST OUTLET
FLEXIBLE DUCT CONNECTION
DUCT RISE IN RESPECT TO AIR FLOW
SPLITTER DAMPER
VOLUME EXTRACTOR
DUCT TURNING DOWN
DUCT TURNING UP
FLAT OVAL DUCT WITH SIZE
ROUND DUCT WITH SIZE
DUCT SECTION - RETURN
DUCT SECTION - SUPPLY
ROUND DUCT
FLAT OVAL DUCT
DUCT DROP IN RESPECT TO AIR FLOW
LOWER - EQUIPMENT NUMBER
UPPER - EQUIPMENT DESIGNATION
CONNECT NEW TO EXISTING
THERMOSTAT
SMOKE DETECTOR
LIMIT OF REMOVAL
UPPER - SECTION DESIGNATION
UPPER - DETAIL DESIGNATION
LOWER - DRAWING NUMBER
LOWER - DRAWING NUMBER
UPPER - EQUIPMENT DESIGNATION
LOWER - EQUIPMENT NUMBER
THERMOSTAT (EXISTING/RELOCATED/NEW)
CARBON DIOXIDE SENSOR
CARBON MONOXIDE/ NITROGEN DIOXIDE SENSOR
TRANSFER DUCT
NEW DUCTWORK
FUTURE DUCTWORK
UP
DN
DIRECTION OF PITCH
DIRECTION OF FLOW
PIPING SPECIALTIES
VALVE (SEE SPECIFICATIONS)
ANGLE VALVE
BALANCING VALVE
DRAIN/HOSE BIBB
RELIEF VALVE
ELBOW-TURNED DOWN
TEE-TURNED DOWN
INVERTED BUCKET TRAP
STRAINER
AIR VENT
WEIGHTED LEVER VALVE
3 WAY CONTROL VALVE
FLOAT & THERMOSTATIC TRAP
PRESSURE REDUCING VALVE
PIPE ANCHOR
ELBOW-TURNED UP
REDUCER
BLIND FLANGE
COMPANION FLANGE
UNION
PIPE CAP
THERMOMETER
FLOW VENTURI
PIPE GUIDE
2 WAY CONTROL VALVE
GAUGES (PRESSURE)
FLEXIBLE PIPE CONNECTION
FLOW MEASURING STATION
CHECK VALVE
TRIPLE DUTY VALVE
BT
F&TT
A
G
A
MECHANICAL LEGEND
VOLUME DAMPER
TAGS - EQUIPMENT, DRAWING
VD
HUMIDIFIERH
H HUMIDITY SENSOR
T
T TEMPERATURE SENSOR
T TEMPERATURE SENSOR (EXISTING/RELOCATED/NEW)*E/R/N
P PRESSURE SENSOR
SP DUCT STATIC PRESSURE SENSOR
DIFFERENTIAL PRESSURE SENSORDP
HYDROGEN SENSORH2
BP BUILDING STATIC PRESSURE SENSOR
FM FLOW METER
BTU BTU/FLOW METER
MOTORIZED EQUIPMENT (FPT)
MIDDLE - MAX CFM OR MBH
UPPER - EQUIPMENT DESIGNATIONFPT-
MAX
MIN
FPT-
MBH
GPMLOWER - MIN CFM OR GPM
NON-MOTORIZED EQUIPMENT (VV, EXV)
MIDDLE - MAX CFM OR MBH
UPPER - EQUIPMENT DESIGNATIONEQP
MAX
MIN
EQP
MBH
GPMLOWER - MIN CFM OR GPM
ABBREVIATIONS
ETR
AD
ACD
AFF
AP
CFM
DB
DX
EP
EAT
ATC
EWT
FLA
EXH
FD
GPH
FPM
GPM
HP
LAT
LRA
LWT
LBS/HR
CO
FSD
EXISTING TO REMAIN
LEAVING WATER TEMPERATURE
LEAVING AIR TEMPERATURE
LOCK ROTOR AMPS
POUNDS PER HOUR
AUTOMATIC CONTROL DAMPER
GALLONS PER HOUR
GALLONS PER MINUTE
EXHAUST
CUBIC FEET PER MINUTE
ACCESS DOOR
ABOVE FINISHED FLOOR
DRY BULB
FIRE DAMPER
ACCESS PANEL
AUTOMATIC TEMPERATURE CONTROL
DIRECT EXPANSION
ENTERING AIR TEMPERATURE
ELECTRIC PNEUMATIC RELAY
ENTERING WATER TEMPERATURE
FULL LOAD AMPS
HORSEPOWER
FEET PER MINUTE
CLEAN OUT
COMBINATION FIRE DAMPER/SMOKE DAMPER
NIC
MAX
MBH
MIN
MD
NO
OA
PD
OBD
PRV
RH
RA
RPM
SD
SMD
SP
SPD
WB
VD
NC
OED
WMS
NOT IN CONTRACT
MINIMUM
MOTORIZED DAMPER
MAXIMUM
THOUSAND BTU PER HOUR
SPLITTER DAMPER
REVOLUTIONS PER MINUTE
STATIC PRESSURE (INCHES OF WATER)
SMOKE DETECTOR
SMOKE DAMPER
RELATIVE HUMIDITY
WET BULB TEMPERATURE °F
VOLUME DAMPER
OUTSIDE AIR
RETURN AIR
NORMALLY OPEN
PRESSURE REDUCING VALVE
PRESSURE DROP
OPPOSED BLADE DAMPER
NORMALLY CLOSED
OPEN END DRAIN
1/2" x 1/2" GALVANIZED WIRE MESH SCREEN
F
BFW
CHWS
CWM
CD
CWS
FOS
CWR
CHWR
FOR
G
FOG
GS
HSC
HSS
HWS
HWR
LSC
MSS
LSS
PC
RL
RS
RHG
MSC
CA
GR
FILL
REFRIGERANT HOT GAS
MEDIUM PRESSURE STEAM SUPPLY
REFRIGERANT SUCTION
MEDIUM PRESSURE STEAM CONDENSATE RETURN
PUMPED CONDENSATE
REFRIGERANT LIQUID
BOILER FEED WATER
HIGH PRESSURE STEAM CONDENSATE RETURN
HOT WATER SUPPLY
FUEL OIL GAUGE
CITY WATER MAKEUP
CONDENSATION DRAIN
GLYCOL SUPPLY
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
FUEL OIL SUPPLY
FUEL OIL RETURN
GAS
HOT WATER RETURN
HIGH PRESSURE STEAM SUPPLY
LOW PRESSURE STEAM SUPPLY
LOW PRESSURE STEAM CONDENSATE RETURN
COMPRESSED AIR
GLYCOL RETURN
PIPING SYSTEMS
14 x 6
14 x 6
SA SUPPLY AIR
EXISTING PIPE TO BE REMOVED
DUCT SECTION - EXHAUST14 x 6
GLOBE VALVE
BALL VALVE
BUTTERFLY VALVE
EA EXHAUST AIR
FIRE SMOKE DAMPER (VERTICAL)
FIRE DAMPER (HORIZONTAL)
FIRE SMOKE DAMPER (HORIZONTAL)
FIRE DAMPER (VERTICAL)
FD
FD
FSD
FSD
SMOKE DAMPER (HORIZONTAL)
SMOKE DAMPER (VERTICAL)
SD
SD
planninarchitectureinteriors
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
AHA Consulting Engineers24 Hartwell Avenue, 3rd floorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
ISSUED FOR BID
NOT FOR CONSTRUCTION
12" = 1'-0"
4/8
/2019
3:0
9:5
7 P
M
M0.00179.18.00
04/08/19
HVAC LEGEND & GENERALNOTES
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
Issuance Schedule
Number Date Description
TAKE OFF FITTINGTAKE OFF FITTING
ALTERNATE RECTANGULAR BRANCH DUCT TAKE OFFS
BRANCHBRANCH
AIR FLOW
VDVD
45° RECTANGULARTAKE OFF
ALTERNATE ROUND BRANCH DUCT TAKE OFFS
ALTERNATEPREFERRED
VDVD
AIR FLOW
VDVDVD
ALTERNATE
TAKE OFF FITTINGTAKE OFF FITTING
PREFERRED ALTERNATE
TAKE OFF FITTING
ALTERNATE
TAKE OFF FITTING
ALTERNATE
TAKE OFF FITTING
RECTANGULAR BELL MOUTH FITTING
MODEL RBMD
STANDAR 45º REGULAR TO ROUNDBOOT CONNECTIONMODEL 33000
OVAL-BELLMOUTHCONNECTIONMODEL OVBMD
MINI-BELLMOUTHCONNECTION MODEL MBMD
BELL MOUTH MODEL BMD W/END FLAPS BENT OVER
BELL MOUTH CONNECTION MODEL BMD
NOTES:
ALL ROUND AND RECTANGULAR BELL MOUTH FITTINGS SHALLBE INCLUDED WITH THE FOLLOWING STANDARD FEATURES:1. NEOPRENE GASKET TO MINIMIZE AIR LEAKAGE.2. PRE-DRILLED HOLES FOR QUICK MOUNTING.3. CONSTRUCTED OF HEAVY DUTY GALVANIZED STEEL.
OPTIONAL FEATURES SHALL INCLUDE THE FOLLOWING:1. 26 GAUGE GALVANIZED QUADRANT VOLUME DAMPER WITH
TIGHT FITTING GASKETING TO MINIMIZE LEAKAGE AT DAMPERPIVOT POINTS.
2. HEAVY DUTY HARDWARE IS AVAILABLE FOR APPLICATIONSWITH INCREASED STATIC PRESSURE.
SUPPLY DUCT
VOLUME DAMPER
BELLMOUTH TAKE-OFF
DRAW BAND WITH SILICONE SEALER
CEILING DIFFUSER
FLEX DUCT MAX LENGTH = 5'-0"
FLEX DUCT SIZE SHALL MATCH DIFFUSER NECK SIZE.
CEILING
DRAW BAND WITH SILICONE SEALER
FLEXIBLE DUCT (USE AS REQ'D.
FOR DIFFUSER ALIGNMENT)
CEILING DIFFUSER. COORDINATE
FRAME/MOUNTING W/ARCHITECTURAL CEILING TYPE.REFER TO ARCH DOCUMENTS.
CEILING
HARD ELBOW
SUPPORT FROM UNDERSIDE
OF STRUCTURE (TYP)
VOLUME DAMPER
SUPPLY AIR DUCT
BELLMOUTHTAKEOFF
W/DAMPER (TYP)
NOTES:
1. MAXIMUM SAG 1/2" PER FOOT.
DUCTWORK & DIFFUSER
BACKPAN SHALL BEINSULATED
2 FT 2 FT 2 FT
5 FT MAX
18"x12"
12"x12"
10"x8"
30"x14"
24"x14"
PLAN VIEW
(PLENUM TO PLENUM)
SECTION
(PLENUM TO PLENUM TRANSFER)
FD
SEE NOTE 2
WALL
1" INTERNAL LINING (TYP.)
FD
SEE NOTE 2
SEE NOTE 3
FINISHED CEILING
18" 18"
8"
1" INTERNAL LINING (TYP.)
NOTES:
REFER TO ARCHITECTURAL DRAWINGS FOR FULL HEIGHT WALL PARTITIONSPROVIDE TRANSFER AIR DUCT IN EACH ROOM AND/OR WHERE SHOWN ON THE DRAWINGS.WHERE CFM IS GREATER THAN THE SCHEDULE (TO THE RIGHT), PROVIDE MULTIPLE TRANSFER DUCTS TO ACCOMMODATE.
1. SUPPORT TRANSFER DUCT FROM STRUCTURE ABOVE.2. PROVIDE FIRE DAMPER, WHERE APPLICABLE (SEE ARCHITECTURAL PLANS FOR RATED WALLS).3. OPEN END DUCT WxH, SEE TRANSFER DUCT SCHEDULE.
TRANSFER DUCT SCHEDULE
CFM DUCT SIZE
0 - 250
251 - 500
501 - 700
701 -10001001 - 1300
18"
18"
STYLE 45
YQ R
STYLE 24
STYLE 32
I
STYLE 34
B
STYLE 42
S
C
STYLE 10L
STYLE 35
K
STYLE 33 STYLE 10S
L
U V W
STYLE 20L
STYLE 41STYLE 37
M
STYLE 20S
F
STYLE 43
X
STYLE 44
H
STYLE 23
A
STYLE 40 STYLE 10
J T
STYLE 20 STYLE 36
D E
STYLE 30
G
STYLE 22
STYLE 21L
N O
STYLE 21S
STYLE 31
P
1 5 7
1 5 7
1 5 7
1 5 7
1 5 7
1 5 7
1 5 7
1 5 7
1 5 7
1 5 7
1 5 7
2 7
2 7
2 7
2 7
2 7
3
3
6
6
6
6
6
6
4
4
4
4
PER ARCH
LD-4
LD-3
CEILING
CEILING
15"x18"SD-8
LD-1
LD-2
RG-2
RG-1
48"L x 1 SLOT
24"x24"
48"x24"
RD-1
RD-4
RD-5
RD-3
RD-2
SD-11
SD-10
SD-9
6"x6"
12"x12"
18"x18"
15"x15"
9"x9"
18"x21"
21"x21"
18"x18"
SD-3
SD-6
SD-7
SD-4
SD-5
SD-2
SD-1
9"x9"
9"x12"
12"x12"
12"x15"
15"x15"
6"x9"
6"x6"
CEILINGSTEELSUPPLY
SUPPLY
SUPPLY
RETURN
RETURN
ALUMINUM
STEEL
STEEL
RETURN
RETURN
RETURN
RETURN
RETURN
SUPPLY
SUPPLY
SUPPLY
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
SUPPLY
SUPPLY
SUPPLY
SUPPLY
SUPPLY
SUPPLY
SUPPLY
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
CEILING
241 - 350
NONE
NONE
351 - 400
776 - 935NONE
1,126 - 1,310
1,311 - 1,500
1,501 - 3,500
0 - 160
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
0 - 1,500
161 - 240
936 - 1,125
776 - 1,125
0 - 120
501 - 775
281 - 500
121 - 280
NONE
NONE
NONE
NONE
NONE
NONE
NONE
186 - 280
281 - 375
376 - 500
501 - 625
626 - 775
121 - 185
0 - 120
(1) 1" SLOT/ 8"Ø INLET.
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
SUPPLY
SUPPLY
ALUMINUM
ALUMINUM
ALUMINUM
48"L x 2 SLOT
48"L x 3 SLOT
48"L x 4 SLOT
(2) 1" SLOT/ 10"Ø INLET.
(3) 1" SLOT/ 12"Ø INLET.
(4) 1" SLOT/ 12"Ø INLET.
241 - 350
351 - 400
666 - 800
956 - 1,115
1,116 - 1,300
1,501 - 3,500
0 - 160
0 - 1,500
161 - 240
801 - 955
666 - 955
401 - 665
161 - 400
161 - 225
226 - 320
321 - 400
401 - 530
531 - 665
101 - 160
0 - 100
0 - 100
101 - 160
SELECTION BASED ON PRICE
REMARKS1. INDUCTION AIR DIFFUSER WITH 24"x24" LAY-IN BORDER.2. INDUCTION AIR DIFFUSER WITHOUT INDUCTION VANES.3. RETURN AIR GRILLE (PERFORATED RETURN PANEL - STEEL CONSTRUCTION).4. WITH ACOUSTICALLY LINED PLENUM.5. DIFFUSER CONNECTIONS SHALL BE ON THE INSIDE NECK AND SEALED AIR TIGHT.6. ALUMINUM SHALL BE USED IN WET LOCATIONS SUCH AS SHOWER ROOMS, GLASSWASH ROOMS, ETC.7. PROVIDE A DIFFUSER BOOT. REFER TO DETAILS FOR REQUIREMENTS.
THE FOLLOWING DIFFUSER CALLOUTS ARE FOR SQUARE CALLOUTS ONLY (SD-1, 3, 5, 7, 9 & 11)
THE FOLLOWING DIFFUSER CALLOUTS ARE FOR RECTANGULAR CALLOUTS ONLY (SD-2, 4, 6, 8 & 10)
TBD3100
PFRF
SMD
SMX 35
35
35
35
35
35
35
35
35
35
35
0.105
0.106
0.068
0.106
0.060
0.068
0.066
0.086
0.092
0.012
0.099
0.035
0.043
0.130
0.068
0.071
0.072
0.101
0.073
0.046
0.076
0.099
PFRF
TBD3100
TBD3100
TBD3100
35
35
35
35
35
35
35
35
35
35
35
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
24"x16"
24"x12"
18"x12"
12"x10"
12"x8"
14"x6"
10"x6"
6"x6"
SR-4
SR-8
SR-7
SR-6
SR-5
SR-3
SR-2
SR-1
SUPPLY STEEL
SUPPLY
SUPPLY
SUPPLY
SUPPLY
STEEL
STEEL
STEEL
STEEL
SUPPLY
SUPPLY
SUPPLY
STEEL
STEEL
STEEL
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
EXP/CLG/WALL
PER ARCH
PER ARCH
PER ARCH
YES 201 - 275
891 - 1,250
591 - 890
366 - 590
276 - 365
YES
YES
YES
YES
141 - 200
91 - 140
0 - 90
YES
YES
YES520
201 - 275
891 - 1,250
591 - 890
366 - 590
276 - 365
141 - 200
91 - 140
0 - 9035
35
35
35
35
35
35
35
30
30
30
30
30
30
30
300.041
0.034
0.029
0.042
0.041
0.029
0.030
0.038
SMX
SMX
SMX
SMX
SMX
SMX
SMX
SMX
SMX
SMX
520
520
520
520
520
520
520
SMD
SMD
SMD
SMD
ER-1 6"x6" EXHAUST STEEL CEIL./WALL NONE 0 - 70PER ARCH530 20 200.054 0 - 70
ER-2 8"x8" EXHAUST STEEL CEIL./WALL NONE 71 - 150PER ARCH530 20 200.054 71 - 150
ER-3 10"x10" EXHAUST STEEL CEIL./WALL NONE 151 - 240PER ARCH530 20 200.054 151 - 240
ER-4 12"x12" EXHAUST STEEL CEIL./WALL NONE 241 - 350PER ARCH530 20 200.054 241 - 350
ER-5 14"x14" EXHAUST STEEL CEIL./WALL NONE 351 - 470PER ARCH530 20 200.054 351 - 470
ER-6 16"x16" EXHAUST STEEL CEIL./WALL NONE 471 - 600PER ARCH530 20 200.054 471 - 600
EXP/CLG/WALL
EXP/CLG/WALL
EXP/CLG/WALL
EXP/CLG/WALL
EXP/CLG/WALL
EXP/CLG/WALL
EXP/CLG/WALL
6.
6.
6.
6.
6.
6.
6.
6.
6.
6.
6.
FINISH
DIFFUSER, REGISTER & GRILLE SCHEDULE
SYMBOL SIZE MATERIALFUNCTION TYPE DAMPER REMARKSMODEL TP
CFM RANGE
OPEN OFFICE
MAX NC CFM RANGE
ENCLOSED OFFICE& CONF. ROOM
MAX NC
planninarchitectureinteriors
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
AHA Consulting Engineers24 Hartwell Avenue, 3rd floorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
ISSUED FOR BID
NOT FOR CONSTRUCTION
As indicated
4/8
/2019
3:1
0:0
0 P
M
M0.01179.18.00
04/08/19
HVAC SCHEDULES &DETAILS
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
1/8" = 1'-0"1
BELL MOUTH CONNECTION DETAIL1/8" = 1'-0"
3
CEILING DIFFUSER BRANCH TAKE-OFFDETAIL (FLEX)
12" = 1'-0"4
CEILING DIFFUSER BRANCH TAKEOFF
1/8" = 1'-0"6
TRANSFER DUCT DETAIL & SCHEDULE
Issuance Schedule
Number Date Description
I. GENERAL
A. THE WORK COVERED CONSISTS OF FURNISHING ALL LABOR AND MATERIALS NECESSARY TO INSTALL,
COMPLETE AND READY FOR CONTINUOUS OPERATION, THE HEATING, VENTILATING AND AIR CONDITIONING
SYSTEMS, APPARATUS AND EQUIPMENT FOR VERTEX FAN PIER B 12TH FLOOR CALL CENTER.
B. SHOP DRAWINGS OF ALL SPECIFIED EQUIPMENT AND APPARATUS SHALL BE SUBMITTED TO THE ARCHITECT
FOR APPROVAL.
C. CODES: ALL EQUIPMENT AND MATERIALS FURNISHED UNDER THE HVAC SUBCONTRACTS AND LABOR
PERFORMED HEREIN SHALL BE IN COMPLETE ACCORDANCE WITH THE MASSACHUSETTS STATE BUILDING
CODES, THE CITY OF WATERTOWN, NATIONAL FIRE PROTECTION ASSOCIATION, AND INSURANCE
REGULATIONS AND REQUIREMENTS GOVERNING SUCH WORK.
D. PERMITS: ANY AND ALL PERMITS REQUIRED FOR INSTALLATION OF ANY MATERIAL SHALL BE OBTAINED AS
PART OF THE WORK OF THE SPECIFICATION, INCLUDING ALL FEES OR EXPENSES INCURRED.
E. INSTRUCTIONS: DURING THE ASSEMBLY AND INSTALLATION OF ALL HVAC SYSTEMS, THE OWNER'S
OPERATING PERSONNEL SHALL BE INSTRUCTED REGARDING ITS OPERATION AND MAINTENANCE. AN 80
HOUR INSTRUCTION PERIOD SHALL BE PROVIDED AFTER COMPLETION OF PROJECT. OPERATION AND
MAINTENANCE MANUALS SHALL BE REQUIRED.
F. GUARANTEE: ALL MATERIALS AND EQUIPMENT FURNISHED AND INSTALLED SHALL BE GUARANTEED IN
WRITING FOR ONE (1) YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION.
G. RECORD DRAWINGS: PURCHASE AND MAINTAIN AT THE JOB SITE A COMPLETE AND SEPARATE BLACK LINE
SET OF PRINTS OF THE CONTRACT DRAWINGS ON WHICH ACCURATELY INDICATE DAILY PROGRESS BY
COLORING MATERIALS AND APPARATUS AS INSTALLED. SCHEDULES SHALL BE MODIFIED TO REFLECT DATA
CONSISTENT WITH THAT OF THE INSTALLED EQUIPMENT. CLEARLY SHOW ALL CHANGES TO THE WORK AS A
RESULT OF CHANGE ORDERS, INSTRUCTIONS ISSUED BY THE ARCHITECT OR CONDITIONS ENCOUNTERED IN
THE FIELD. ACCURATELY INDICATE THE LOCATION, SIZE, TYPE AND ELEVATION OF NEW UTILITIES AND THEIR
RELATIONSHIP TO EXISTING UTILITIES. THE MARKED UP AND COLORED IN PRINTS WILL BE USED AS A GUIDE
FOR DETERMINING THE PROGRESS OF THE WORK INSTALLED. THEY SHALL BE INSPECTED WEEKLY AND
SHALL BE CORRECTED IMMEDIATELY IF FOUND INACCURATE OR INCOMPLETE. REQUISITIONS FOR PAYMENT
WILL NOT BE APPROVED UNTIL THE DRAWINGS ARE ACCURATE AND UP_TO_DATE. AT THE COMPLETION OF
THE WORK, SUBMIT ONE (1) SET OF MARKED UP PRINTS FOR REVIEW AND COMMENT. AFTER REVIEW AND
COMMENT, THESE MARKED UP PRINTS SHALL BE USED IN THE PREPARATION OF THE RECORD DRAWINGS.
THE RECORD DRAWINGS SHALL CONSIST OF THESE PRINTS (CORRECTED) PREVIOUSLY INDICATED, AS WELL
AS TWO (2) CAD DISKS OF THE FINAL COORDINATION DRAWINGS, CORRECTED ON THE BASIS OF THE
ARCHITECT/ENGINEER'S FINAL COMMENTS. OBTAIN AND PAY FOR ONE (1) SET OF REPRODUCIBLES AND CAD
DISKS (AUTOCAD RELEASE 2004 MINIMUM OR COMPATIBLE SYSTEM) APPLICABLE TO THIS SECTION. MAKE ALL
MODIFICATIONS TO THESE REPRODUCIBLES AS SHOWN ON THE MARKED UP PRINTS. REMOVE ALL
SUPERSEDED DATA TO SHOW THE COMPLETED INSTALLATION. THE RECORD DRAWINGS MAY BE MADE FROM
THE ORIGINALS OF THE CONTRACT DRAWINGS. ARRANGE WITH THE ARCHITECT TO HAVE THESE
REPRODUCIBLES MADE FROM THE ORIGINALS. DELIVER THE COMPLETED REPRODUCIBLE RECORD
DRAWINGS AND CAD DISKS PROPERLY TITLED AND DATED TO THE ARCHITECT. THESE RECORD DRAWINGS
SHALL BECOME THE PROPERTY OF THE OWNER.
H. INSPECTION: ALL WORK SHALL BE SUBJECT TO THE INSPECTION OF THE OWNER, THE ARCHITECT AND SUCH
OTHER INSPECTORS HAVING JURISDICTION. A PROPERLY EXECUTED CERTIFICATE OF INSPECTION SHALL BE
PROVIDED.
I. EXAMINATION OF SITE: THE HVAC SUBCONTRACTOR, BEFORE SUBMITTING PRICES OR BEGINNING WORK,
SHALL THOROUGHLY EXAMINE THE SITE AND CONTRACT DOCUMENTS. NO CLAIM FOR EXTRA COMPENSATION
WILL BE RECOGNIZED IF DIFFICULTIES WHICH AN EXAMINATION OF SITE CONDITIONS AND CONTRACT
DOCUMENTS PRIOR TO EXECUTING CONTRACT WOULD HAVE REVEALED.
J. COORDINATION DRAWINGS: PRIOR TO THE PURCHASING AND FABRICATION OF MATERIALS, EACH
SUBCONTRACTOR SHALL PREPARE COORDINATION DRAWINGS FOR ALL FLOORS/AREAS SHOWING THE SIZE
AND LOCATION OF HIS/HER EQUIPMENT AND LINES. THE COORDINATION DRAWINGS SHALL BE PRODUCED ON
AUTOCAD RELEASE 2004 MINIMUM OR COMPATIBLE SYSTEM. A DISC AND ONE (1) SET OF REPRODUCIBLES
(ALL-TRADE COMPOSITE) SHALL BE PROVIDED TO THE ARCHITECT/ENGINEER FOR REVIEW. COORDINATION
DRAWINGS SHALL BE 3/8” = 1'-0” SCALE. PREPARE AND SUBMIT FOR REVIEW, AT THAT SCALE OR LARGER,
PLANS AND SECTIONS. THE COST OF PREPARING AND REPRODUCING THESE DRAWINGS WILL BE INCLUDED
AS PART OF THIS CONTRACT. THE HVAC SUBCONTRACTOR SHALL PREPARE THE INITIAL DRAWINGS AND
CIRCULATE THE DRAWINGS TO THE OTHER TRADES (FIRE PROTECTION, PLUMBING AND ELECTRICAL) SO
THEY CAN INDICATE THEIR WORK. COORDINATION DRAWINGS SHALL NOT BE CONSTRUED AS REPLACING
ANY SHOP DRAWINGS. THE PLUMBING SUBCONTRACTOR SHALL BE ADDITIONALLY RESPONSIBLE FOR
PREPARING DRAWINGS INDICATING ALL THE BURIED OR UNDERGROUND PLUMBING SYSTEMS. INCLUDE IN
THESE DOCUMENTS ALL OTHER UNDERGROUND COMPONENTS SUCH AS, BUT NOT LIMITED TO, UNDERSLAB
DRAINAGE SYSTEMS, FOUNDATION DRAINAGE SYSTEMS, FOOTINGS, FOUNDATION WALLS, PITS, TIE BEAMS,
ELECTRIC AND TELEPHONE DUCT BANKS.
K. PROTECTION OF PROPERTY: PROTECT ALL NEW AND EXISTING WORK BEFORE, DURING AND AFTER
INSTALLATION.
L. TESTS: THE HVAC SUBCONTRACTOR SHALL PERFORM ALL TESTS AT THE COMPLETION OF THE WORK AND
THE RESULTS FURNISHED TO THE OWNER AND ARCHITECT IN WRITING.
M. UPON COMPLETION OF ALL WORK, THE HVAC SUBCONTRACTOR SHALL FURNISH, IN DUPLICATE,
CERTIFICATES OF INSPECTIONS FROM ALL INSPECTORS AND AUTHORITIES HAVING JURISDICTION,
NOTARIZED LETTERS FROM THE MANUFACTURERS STATING THAT AUTHORIZED FACTORY ENGINEERS HAVE
INSPECTED AND TESTED THE INSTALLATION OF THEIR RESPECTIVE SYSTEMS AND FOUND SAME TO BE IN
PERFECT OPERATING CONDITION.
N. CONTRACT DRAWINGS: THE CONTRACT DRAWINGS ARE DIAGRAMMATIC AND INDICATE ONLY THE GENERAL
ARRANGEMENTS OF WORK. IT IS NOT THE INTENT OF THESE DRAWINGS TO SHOW EVERY PIPE, RISE, DROP,
ELBOW, ETC. ANY ADDITIONAL WORK NOT SHOWN AND REQUIRED TO INSTALL THE HVAC SYSTEMS SHALL BE
INCLUDED AS PART OF THIS CONTRACT.
O. INSTALLATION OF MECHANICAL EQUIPMENT AND/OR SYSTEMS SHALL BE IN ACCORDANCE WITH THE SEISMIC
REQUIREMENTS IDENTIFIED IN THE MASSACHUSETTS STATE BUILDING CODE, EIGHTH (8TH) EDITION.
II. SCOPE
A. THE WORK OF THIS SECTION CONSISTS OF ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED TO PROVIDE
ALL HVAC WORK, NOT SPECIFICALLY DESCRIBED IN OTHER TRADES COMPLETE, IN PLACE, AS SHOWN ON THE
DRAWINGS, SPECIFIED HEREIN AND AS NECESSARY FOR A PROPER INSTALLATION.
B. THE EXTENT OF THE HVAC SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING:
1. INSTALLATION OF NEW LOW PRESSURE DUCTWORK.
2. INSTALLATION AND RELOCATION OF DIFFUSERS
3. ALL OTHER WORK SHOWN OR SPECIFIED.
III. RELATED WORK IN OTHER SECTIONS
A. THE FOLLOWING WORK IS NOT INCLUDED AS WORK IN THIS SECTION AND IS TO BE PERFORMED UNDER
OTHER SECTIONS:
1. CUTTING AND PATCHING.
2. TEMPORARY LIGHT AND POWER.
3. FLASHING AND CAULKING.
4. SETTING OF FRAMES FOR REGISTERS AND ACCESS PANELS.
5. PAINTING.
6. POWER WIRING TO ALL EQUIPMENT.
IV. IDENTIFICATION OF EQUIPMENT AND MATERIAL
A. LABEL EACH PIECE OF MECHANICAL EQUIPMENT WITH A PLASTIC LAMINATE NAMEPLATE WITH A WHITE
BACKGROUND AND WITH THE DESIGNATED EQUIPMENT AND AREA OR SYSTEM SERVED ENGRAVED IN BLACK
LETTERS. NAMEPLATES SHALL BE MANUFACTURED BY SETON NAMEPLATE COMPANY, OR APPROVED EQUAL
BY DENNISON MANUFACTURING COMPANY OR MARKEM COMPANY.
V. SHEETMETAL
A. LOW PRESSURE: FURNISH ALL LOW PRESSURE SHEET METAL DUCTWORK REQUIRED FOR THE VARIOUS
SUPPLY, RETURN AND EXHAUST AIR SYSTEMS. ALL LOW PRESSURE DUCTWORK AND SHEET METAL PLENUMS
SHALL BE CONSTRUCTED OF GALVANIZED STEEL OF U.S. STANDARD GAUGE TO MEET THE LATEST SMACNA
STANDARDS.
B. MEDIUM PRESSURE: ALL MEDIUM PRESSURE DUCTWORK SHALL BE GALVANIZED SHEET STEEL, MEETING
ASTM STANDARD A_93_59_T. THE GAUGE OF ALL DUCT SHALL BE AS LISTED IN SMACNA STANDARD. FOR
RECTANGULAR MEDIUM PRESSURE DUCT THE USE OF "DUCTMATE" FLANGE TRANSVERSE JOINTS WILL BE
ALLOWED. ALL ROUND DUCT THROUGH 36 INCHES IN DIAMETER AND ALL FLAT OVAL DUCT THROUGH 48
INCHES WIDE SHALL BE CONSTRUCTED OF SPIRAL LOCK SEAM OR APPROVED EQUAL CONSTRUCTION. ALL
ROUND DUCT 37 INCHES IN DIAMETER AND OVER AND ALL FLAT OVAL DUCT OVER 48 INCHES WIDE SHALL BE
OF WELDED JOINT CONSTRUCTION.
1. ALL ROUND AND OVAL CONDUIT FITTINGS SHALL BE EQUAL TO UNITED STATES METAL
CORPORATION SPIRAL UNI_SEAL FITTINGS FOR USE WITH THE CONDUIT. USE CONICAL TEES
AND LATERALS WHERE SHOWN. SPECIAL FITTINGS SHALL BE USED AS SHOWN TO GIVE EVEN
AIR FLOW WITH MINIMUM PRESSURE DROP. NINETY DEGREE ELBOWS SHALL BE DIE_FORMED
UP TO AND INCLUDING 8 INCH DIAMETER AND FIVE (5) PIECE FOR 9 INCH DIAMETER AND
LARGER. FORTY FIVE DEGREE ELBOWS SHALL BE DIE_FORMED UP TO AND INCLUDING 8 INCH
DIAMETER AND THREE (3) PIECE FOR 9 INCH DIAMETER AND LARGER.
C. FLEX DUCT: FLEXIBLE DUCT SHALL BE FLEXMASTER TYPE 2 INSULATED DUCT AS MANUFACTURED BY
BUCKLEY ASSOCIATES, SHEET METAL WORKERS LOCAL 17. FLEXIBLE DUCT SHALL BE UL LISTED (UL 181
CLASS 1 AIR DUCT) AND CONSTRUCTED IN ACCORDANCE WITH NFPA STANDARDS 90A AND 90B WITH A
SMOKE/FLAME SPREAD RATING OF 50/25.
D. FLEX CONNECTIONS: FURNISH FLEXIBLE CONNECTIONS BETWEEN ALL DUCTS AND FANS OR FAN UNITS.
FLEXIBLE CONNECTIONS SHALL BE VENTGLASS, FERRO COUSTIFAB MASS LOADED FIBERGLASS REINFORCED
VINYL FABRIC WITH A WEIGHT OF ONE (1) POUND PER SQUARE FOOT. WIDTH OF CONNECTING MATERIAL
SHALL BE NOT LESS THAN 6 INCHES AND MATERIAL SHALL BE INSTALLED TO ALLOW A MINIMUM OF ONE (1)
INCH SPACING BETWEEN THE UNIT AND THE DUCT.
E. INTERNAL LINING: PROVIDE OWENS_CORNING, KRAUF OR PITTSBURGH CORNING ACOUSTICAL DUCT LINING
WITH A MINIMUM DENSITY OF 2 POUNDS PER CUBIC FOOT AS SHOWN AND AS SPECIFIED. THE DUCT SIZE
SHALL BE THE NET INSIDE DIMENSIONS AFTER LINING IS IN PLACE. LINING IN DUCTS SHALL BE ONE INCH
THICK, SIMILAR AND EQUAL TO OWENS_CORNING FIBERGLASS "AEROFLEX" DUCT LINER. LINING SHALL BE
ADHERED TO ALL INTERIOR SURFACES OF DUCT WITH BENJAMIN FOSTER 85_15, OR EQUAL ADHESIVE.
F. VOLUME DAMPERS: PROVIDE MANUAL VOLUME DAMPERS IN ALL LOW PRESSURE SUPPLY, RETURN AND
EXHAUST DUCTS AS SHOWN AND REQUIRED WITH INDICATING AND LOCKING QUADRANTS TO PROPERLY
BALANCE THE AIR SUPPLY, RETURN AND EXHAUST SYSTEMS. DAMPERS SHALL BE TWO (2) GAUGES HEAVIER
THAN THE DUCTS IN WHICH THEY ARE INSTALLED. DAMPER BLADES SHALL BE RIVETED TO THE SUPPORTING
RODS. CAST OR MALLEABLE BRACKETS RIVETED TO THE SIDES OF THE DUCT SHALL BE USED TO SUPPORT
THE DAMPER POSITIONED ROD. IN LIEU OF VOLUME DAMPER, CONTRACTOR SHALL PROVIDE BUCKLEY
BELLMOUTH TAKEOFFS WITH DAMPERS AT ALL BRANCH DUCT LOCATIONS.
VI. TERMINAL UNITS
A. VAV BOXES: PROVIDE SINGLE DUCT VARIABLE AIR VOLUME TERMINAL UNITS OF SIZES AND CAPACITIES AS
SHOWN ON THE DRAWINGS. TERMINALS SHALL BE CONSTRUCTED OF GALVANIZED STEEL. INTERNAL
SURFACES SHALL BE THERMALLY AND ACOUSTICALLY INSULATED. UNITS SHALL BE AS MANUFACTURED BY
PRICE, TITUS, METAL AIRE, OR ENVIRONMENTAL TECHNOLOGIES.
1. THE UNIT SHALL HAVE AN AIR VOLUME REGULATOR PROVIDED WITH AN AVERAGING
DIFFERENTIAL PRESSURE SENSING DEVICE TO COMPENSATE FOR DISTORTED AIR FLOW
CONDITIONS AT THE UNIT INLET. DAMPER OPERATORS, VOLUME REGULATORS, FLOW
CONTROLLERS AND NECESSARY RELAYS SHALL BE FACTORY INSTALLED PNEUMATIC TYPE FOR
NORMALLY (CLOSED)(OPEN) OPERATION AND THOROUGHLY TESTED FOR PROPER
PERFORMANCE. THE DAMPER SHALL (CLOSED)(OPEN) COMPLETELY ON LOSS OF CONTROL AIR
AND SHALL BE CONTROLLED TO PROVIDE PRESSURE INDEPENDENT PROPORTIONAL VARIABLE
VOLUME CONTROL OF THE AIR VOLUME BEING SUPPLIED FROM THE UNIT WITHIN THE LIMITS
SHOWN ON THE DRAWINGS.
VII. DIFFUSERS/REGISTERS/GRILLES
A. PROVIDE PRICE, NAILOR OR METAL*AIRE DIFFUSERS AS SHOWN ON THE DRAWINGS AND AS SPECIFIED
HEREIN.
B. ALL SQUARE AND RECTANGULAR SUPPLY AIR DIFFUSERS SHALL BE ALUMINUM AND HAVE INDUCTION AIR
MIXING VANES SIMILAR AND EQUAL TO PRICE INDUSTRIES AMDEX. FACTORY MOUNTED ALUMINUM OPPOSED
BLADE VOLUME DAMPERS FULL SIZE OF THE NECK SIZE SHOWN SHALL BE PROVIDED AS SHOWN ON
SCHEDULES. ALL DIFFUSER PATTERNS SHALL BE AS SHOWN OR AS REQUIRED TO FIT AIR DISTRIBUTION
PATTERN WITH PORTIONS OF THE NECK BLANKED OFF TO GIVE THE PROPER AIR DISTRIBUTION PATTERN AND
TO LIMIT THE MAXIMUM NECK VELOCITY TO 500 FPM.
C. ALL RETURN AIR DIFFUSERS SHALL BE OF THE SAME DETAILS AS SPECIFIED ABOVE FOR SUPPLY DIFFUSERS
TO MATCH THE PARTICULAR DIFFUSERS USED IN THE SAME ROOM OR AREA AS SHOWN ON THE SCHEDULE.
THE RETURN DIFFUSERS SHALL HAVE OPPOSED BLADE DAMPERS BUT SHALL NOT HAVE INDUCTION VANES.
D. DIFFUSERS SHALL BE PROVIDED WITH INTEGRAL DUCT COLLAR TO ENSURE AIR-TIGHT AND NEAT
INSTALLATION OF DUCT. (DUCT TO BE MOUNTED INSIDE OF DIFFUSER COLLAR)
E. LAY IN APPLICATION SHALL BE PROVIDED WITH 2'X2' LAY IN PANEL. SURFACE MOUNTED APPLICATIONS IN
PLASTER CEILINGS SHALL BE PROVIDED WITH PLASTER FRAMES.
F. ALL DIFFUSERS SHALL BE FINISHED WITH A CROSS LINKED ACRYLIC POWDER COAT. COATING SHALL BE 2.0 -
3.0 MILS DFT AND BE RATED FOR 500 HOUR SALT SPRAY EXPOSURE.
VIII. INSULATION
A. GENERAL: FURNISH ALL MATERIALS NECESSARY FOR THE INSTALLATION OF ALL INSULATION FOR THE HOT
WATER AND ALL DUCT SYSTEMS, INCLUDING ALL RELATED EQUIPMENT. ALL INSULATION SHALL BE AS
MANUFACTURED BY OWENS_CORNING, MANVILLE, CERTAINTEED, KNAUF OR APPROVED EQUAL.
B. SMOKE RATING: INSULATION WHEN INSTALLED, SHALL HAVE COMPOSITE (INSULATION, JACKET AND
ADHESIVE) FIRE AND SMOKE HAZARD RATINGS AS TESTED BY PROCEDURE ASTM_E_84, NFPA 255 AND UL_723,
NOT EXCEEDING A FLAME SPREAD OF TWENTY FIVE (25), FUEL CONTRIBUTION OF FIFTY (50) AND SMOKE
DEVELOPED OF FIFTY (50).
C. ACCESSORIES: ACCESSORIES SUCH AS ADHESIVES, MASTICS, CEMENTS AND TAPES SHALL HAVE THE
COMPONENT RATINGS AS LISTED ABOVE FOR COMPOSITE INSULATION IN A WET AS WELL AS DRY STATE.
D. DUCTWORK INSULATION SCHEDULE
FLEXIBLE FIBERGLASS:
SUPPLY AND OUTSIDE AIR DUCTS (COOLING SYSTEMS) - 1-1/2 INCH THICKNESS WITH FSK FINISH
IX. TESTING, ADJUSTING AND BALANCING
A. BALANCING & ADJUSTING: TEST, ADJUST AND BALANCE ALL SYSTEMS AND MAKE ALL ADJUSTMENTS AS
REQUIRED TO MAKE THEM OPERATE AS SPECIFIED. PUT MECHANICAL EQUIPMENT SPECIFIED HEREIN IN
OPERATION IN THE PRESENCE OF THE ARCHITECT WITH FORTY_EIGHT (48) HOURS NOTICE GIVEN FOR EACH
APPOINTMENT.
B. BALANCING AND ADJUSTING SHALL NOT BEGIN UNTIL ALL HVAC SYSTEMS HAVE BEEN INSTALLED AND ARE IN
FULL WORKING ORDER. PRIOR TO THE START OF BALANCING THE FOLLOWING SHALL BE CHECKED:
ROTATION OF ALL FANS
DAMPERS ARE FREE TO OPEN AND CLOSE
CLEAN FILTERS ARE IN PLACE
C. ALL BALANCING AND ADJUSTING OF AIR AND WATER SYSTEMS SHALL BE DONE IN ACCORDANCE WITH THE
LATEST EDITION OF THE NEBB PROCEDURAL STANDARDS FOR TESTING, ADJUSTING AND BALANCING OF
ENVIRONMENTAL SYSTEMS OR THE LATEST EDITION OF SMACNA'S HVAC SYSTEMS TESTING, ADJUSTING AND
BALANCING.
1. AIR APPARATUS TEST REPORT
a. LOCATION.
b. SYSTEM NUMBER.
c. MANUFACTURER.
d. AIRFLOW, DESIGN AND ACTUAL.
e. TOTAL CFM.
f. TOTAL STATIC PRESSURE.
g. DISCHARGE STATIC PRESSURE.
h. SUCTION STATIC PRESSURE.
i. COIL PRESSURE DROPS (STATIC PRESSURE).
j. FILTER PRESSURE DROPS.
k. MOTOR VOLTS AND AMPS.
l. OUTSIDE AIR AND RETURN AIR CFM.
m. DRIVE DATA.
4. DUCT TRAVERSE
a. SYSTEM ZONE/BRANCH.
b. DUCT SIZE.
c. AREA.
d. DESIGN VELOCITY.
e. DESIGN AIRFLOW.
f. TEST VELOCITY.
g. TEST AIRFLOW.
h. DUCT STATIC PRESSURE.
i. AIR TEMPERATURE.
5. AIR OUTLET REPORT
a. AREA SERVED.
b. OUTLET NUMBER.
c. TYPE.
d. SIZE.
e. AK FACTOR.
f. VELOCITY, DESIGN AND ACTUAL.
g. AIRFLOW, DESIGN AND ACTUAL.
D. THE BALANCING SUBCONTRACTOR SHALL BALANCE AND ADJUST AIR AND WATER SYSTEMS TO MEET DESIGN
REQUIREMENTS+(5)%. BALANCING SHALL BE ACCOMPLISHED BY ADJUSTING DAMPERS, DRIVES, VALVES,
ETC. TO OBTAIN DESIGN REQUIREMENTS.
E. THE HVAC CONTRACTOR SHALL COOPERATE AND MAKE PROVISIONS FOR THE BALANCING SUBCONTRACTOR
AS NEEDED TO ACCOMMODATE THE AIR AND WATER BALANCING. AS PART OF THIS CONTRACT, THE HVAC
SUBCONTRACTOR SHALL PROVIDE AND/OR CHANGE PULLEYS, BELTS, SHEAVES, VALVES AND DAMPERS, AT
NO ADDITIONAL COST, IN ORDER TO PROPERLY BALANCE THE SYSTEMS TO DESIGN REQUIREMENTS.
planninarchitectureinteriors
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
AHA Consulting Engineers24 Hartwell Avenue, 3rd floorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
ISSUED FOR BID
NOT FOR CONSTRUCTION
1/8" = 1'-0"
4/8
/2019
3:1
0:0
1 P
M
M0.02179.18.00
04/08/19
HVAC SPECIFICATION
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
Issuance Schedule
Number Date Description
A5.10
4c
2c
2d 2b
2a
4d
4a
4b
3d 3b
4'-512"
23'-7"
3'-9 1
4 "
3'-113 4"
4'-101 4"
3'-8"
3'-4
3'-43 4"
3'-9
3'-7 34 "
4'-914"
3'-1112"
3'-0"
ELEC
MODULE
ELEC MODULE
ELE
C M
ODU
LE
ELEC
MODULE
ELEC MODULE
ELE
C M
ODU
LE
ELEC MODULE
ELEC M
ODULE
ELE
C M
ODULE
ELEC MODULE
ELEC MODULE
ELEC M
ODULE
ELE
C M
ODULE
ELEC MODULE
ELE
C M
ODULE
ELE
C M
ODULE
ELE
C M
ODULE
ELE
C M
ODULE
ELE
C M
ODU
LEELE
C M
ODU
LE
ELEC MODULE
ELE
C M
ODU
LE
ELEC MODULE
ELE
C M
ODU
LE
ELEC M
ODULE
ELE
C M
ODULE
ELEC M
ODULE
ELEC MODULE
ELEC M
ODULE
ELE
C M
ODULE
ELEC MODULE
ELEC MODULE
ELEC MODULE
ELEC MODULE
ELEC MODULE
ELEC MODULE
ELEC MODULE
ELEC M
ODULE
ELE
C M
ODULE
ELEC MODULE
ELEC M
ODULE
ELEC MODULE
ELEC MODULE
ELEC MODULE
ELE
C M
ODU
LE
ELEC MODULE
ELE
C M
ODU
LE
ELE
C M
ODU
LE
ELEC MODULE
ELEC
MODULE
ELE
C M
ODU
LE
ELEC MODULE
ELE
C M
ODU
LE
ELE
C M
ODU
LE
b1 b1.4 b2 b3 b3.2 b3.5 b4
bF
bE.3
bE
bD.9
bA.8
bB
bB.1
bB.3
bC
bC.3
bD
bA
12345
VAV-1
75
55
6"x10"
14"x10"14"x8"
10"x10" 10"x10"
14"x10"
14"x10"
8"x8"6"x6"
10"ø
16"x10"20"x10"
16"x12"
16"x12"
48"x12"
10"x8"
48"x12"
10"x10"
12"x10"
10"x10"
12"x10"
10"x8"
48"x12"
14"x8"
18"x10"
12"x8"
42"x12"
16"x12"
18"x10"
14"x8"
8"x6"
10"x8"
16"x12"
48"x12"
8"x8"
80"x12"
16"x12"
8"x8"
SD-2
200
(TYP.3)
SD-2
200
(TYP.2)
SD-2
200
SD-2
240
(TYP.2)
SD-2
190
(TYP.2)
SD-2
125
(TYP.4)
SD-2
170
(TYP.4)
SD-1
140
(TYP.6)
SD-2
140
(TYP.3)
RD-1
100
SD-1
75
(TYP. 4)
16"x12"
40"x12"40"x12"
10"x6"
SA
1E
SD-2
200
(TYP.3)
SD-2
200
SD-2
225
SD-3
285
(TYP.2)
SD-3
300
(TYP.2)
SD-2
150
(TYP.2)
SD-1
140
(TYP.2)
FCU
6
ETR
FCU
4
ETR
FPT
1
ETR
FCU
6
ETR
FCU
4
ETR
FCU
3
ETR
FCU
6
ETR
FCU
4
ETR
FPT
1
ETR
FCU
6
ETR
FPT
1
ETR
FCU
4
ETRFCU
4
ETR
SD-1
140
(TYP.4)
SD-1
140
(TYP.3)
SD-2
125
(TYP.4)
FCU
3
ETR
SD-2
140
(TYP.4)
FCU
3
ETR
RG-1
250
RG-1
250
RG-1
250
RG-1
250
SD-1
140
(TYP.3)
RG-1
(TYP)
VAV-1
75
55
VAV-1
75
55
SD-2
125
(TYP.2)
CONFERENCE ROOM12031
CONFERENCE ROOM12113
COPY/MAIL ROOM12012
POD12011
POD12010
POD12009
POD12008
POD12007
POD12006
CONFERENCE ROOM12029
CONFERENCE ROOM12082
CONFERENCE ROOM12083
POD12079
FCU
4
SD-3
400
(TYP.2)
VAV
1
RELOCATE
FCU
1
RELOCATE
FPT
3
FPT
3
SD-2
200
(TYP. 4)
SD-1
75
(TYP. 2)
NEW
T
T
T
TT
T
T
T
T
T
T
TT T
R
R
R
R
R
FPT
3
ETR
FPT
2
ETR
VAV-1
225
75
REBALANCE
ETR
VAV-1
225
75
NEW
8"x8"
TN
1
KEYED NOTES:
1. NEW 3/4" HWS&R PIPING TO NEW VAV-1 BOX.
b1 b1.4 b2 b3 b3.2 b3.5 b4
bF
bE.3
bE
bD.9
bA.8
bB
bB.1
bB.3
bC
bC.3
bD
bA
12345
VAV-1
75
55
6"x10"
14"x10"14"x8"
10"x10" 10"x10"
14"x10"
14"x10"
8"x8"
10"ø
16"x10"20"x10"
16"x12"
16"x12"
8"x8"
48"x12"
10"x8"
48"x12"
10"x10"
12"x10"
10"x10"
12"x10"
10"x8"
48"x12"
14"x8"
18"x10"
12"x8"
42"x12"
16"x12"
18"x10"
14"x8"
8"x6"
10"x8"
16"x12"
48"x12"
8"x8"
80"x12"
16"x12"
8"x8"
SD-2
200
(TYP.3)
SD-2
200
(TYP.2)
SD-2
200
SD-2
240
(TYP.2)
SD-2
190
(TYP.2)
SD-2
125
(TYP.4)
SD-2
170
(TYP.4)
SD-1
140
(TYP.6)
SD-2
140
(TYP.3)
RD-1
100
RD-1
100
SD-1
75
(TYP. 4)
16"x12"
40"x12"40"x12"
10"x6"
SA
1E
SD-2
200
(TYP.3)
SD-2
200
SD-2
225
SD-3
285
(TYP.2)
SD-3
300
(TYP.2)
SD-2
150
(TYP.2)
SD-1
140
(TYP.2)
FCU
6
ETR
FCU
4
ETR
FPT
1
ETR
FCU
6
ETR
FCU
4
ETR
FCU
3
ETR
FCU
6
ETR
FCU
4
ETR
FPT
1
ETR
FCU
6
ETR
FPT
1
ETR
FCU
4
ETRFCU
4
ETR
SD-1
140
(TYP.4)
SD-1
140
(TYP.3)
SD-2
125
(TYP.4)
FCU
3
ETR
SD-2
140
(TYP.4)
FCU
3
ETR
RG-1
250
RG-1
250
RG-1
250
RG-1
250
SD-1
140
(TYP.3)
RG-1
(TYP)
VAV-1
75
55
VAV-1
75
55
SD-2
125
(TYP.2)
VAV
1
RELOCATE
FCU
1
RELOCATE
T
T
T
T T
T
T
T
T
T
T
T
T
TR
R
R
R
R
FPT
3
ETR
FPT
2
ETR
VAV
1
VAV-1
225
75
planninarchitectureinteriors
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02118Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
AHA Consulting Engineers24 Hartwell Avenue, 3rd floorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
ISSUED FOR BID
NOT FOR CONSTRUCTION
1/8" = 1'-0"
4/8
/2019
3:1
0:0
6 P
M
M1.12179.18.00
04/08/19
HVAC 12TH FLOORDUCTWORK PLAN
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
1/8" = 1'-0"1
Level 12 HVAC Ductwork Part Plan1/8" = 1'-0"
2Level 12 HVAC Ductwork Demo Part Plan
Issuance Schedule
Number Date Description
VS
VSS
CEILING MOUNTED VACANCY SENSOR. LUTRON #LOS-CDT-500-WH.
GENERAL NOTES
LIGHTING FIXTURE NOTES
RENOVATION NOTES
T/D
P
S
J
J
R
FCU4
MOTORS AND CONTROLS
LIGHTING FIXTURE SYMBOLS
RECEPTACLES AND OUTLETS
BRANCH CIRCUIT AND FEEDER SYMBOLS
PANELBOARDS AND TERMINAL CABINETS
MISCELLANEOUS
SWITCHING SYMBOLS
EXISTING EQUIPMENT
ABBREVIATIONS
P
30A
30A
20A
100A
70A
S
CB
5
4#1-1 1/2" C
H411-1,3
BT
T
C
J
W
NL
NL }
3 3a
A C
a
Z# Z#
KVA
LTG
MTG
MLO
MCB
NTS
PVC
NO, #
SWBD
MTD
XL
XR
XM
X
WP
TYP
SN
PC
JB
KW
AFF
ATS
CKT
DWG
GND
EMT
HVAC
GFI
HP
IC
GC
EC
CU
CB
C
C.
J
GFEP
TS
STR
VFD
DS
F-DS
FC
J
J
SMC
LCP
Z#
TV
TV
RS
HUNG CEILING.
(30 AMP, 20 AMP FUSE, 3 POLE)
MAGNETIC MOTOR STARTER
EXPOSED IN UNFINISHED AREAS
LIGHTING OR POWER PANEL
TRANSFORMER, DRY TYPE
DUPLEX CONVENIENCE RECEPTACLE. MOUNTING HEIGHT 18" AFF.
DUPLEX CONVENIENCE RECEPTACLE. MOUNTING HEIGHT 6" ABOVE COUNTER OR 42" AFF.
DISCONNECT SWITCH-UNFUSED TYPE, SIZE AS INDICATED (30 AMP, 3 POLE)
SEE MECHANICAL EQUIPMENT SCHEDULE.
MECHANICAL EQUIPMENT TAG. FOR ELECTRICAL CHARACTERISTICS
(100 AMP FRAME, 70 AMP TRIP, 3 POLE)
ENCLOSED CIRCUIT BREAKER-SIZE AS INDICATED
DISCONNECT SWITCH-FUSED TYPE, SIZE AS INDICATED
MOTOR-NUMERAL INDICATES HORSEPOWER
THERMAL MOTOR SWITCH, "P" INDICATES PILOT LIGHT
BRANCH CIRCUIT OR FEEDER CONCEALED IN CONSTRUCTION IN FINISHED AREAS,
FLEXIBLE CONNECTION TO MOTOR OR EQUIPMENT
HOME RUN TO PANELBOARD H411 CIRCUITS #1 AND #3
INDICATES 4#1 AWG CONDUCTORS IN 1 1/2" CONDUIT
AND 1/2" CONDUIT UNLESS OTHERWISE NOTED
INDICATES TWO WIRES. GROUND WIRE(S) NOT INDICATED. MINIMUM SIZE #12 AWG
BRANCH CIRCUIT-DIAGONAL LINES INDICATE NUMBER OF WIRES NO DIAGONAL LINES
CONDUIT STUB "6" ABOVE CEILING WITH PULL CORD AND BUSHING
DIRECT CONNECTION TO EQUIPMENT
BRANCH CIRCUIT OR FEEDER, CONCEALED IN OR UNDER FLOOR SLAB
TELEPHONE TERMINAL BACKBOARD-SIZE AS INDICATED
DOUBLE DUPLEX CONVENIENCE RECEPTACLE. MOUNTING HEIGHT 18" AFF.
JUNCTION BOX
HEIGHT 4'-0" AFF. WITH 3/4"C. AND PULLSTRING TO ABOVE HUNG CEILING.
TELEPHONE/DATA OUTLET MOUNTING HEIGHT 18" AFF. WITH 3/4"C. AND PULLSTRING TO ABOVE
GROUND FAULT INTERRUPTING RECEPTACLE MOUNTED 6" ABOVE COUNTER
TELEPHONE OUTLET MOUNTING HEIGHT 18" AFF "W" INDICATES WALL PHONE MOUNTING
PANELBOARD DESIGNATIONS
PANEL NUMBER
VOLTAGE "2"-120/208V,"4"-277/480V
"H"-HOUSE, "T"-TENANT, "E"-EMERGENCY (LIFE SAFETY),
H411
"LS"-LEGAL STANDBY, "O"-OPTIONAL STANDBY, "UP"-UPS.
G
DOTTED DENOTES EXISTING EQUIPMENT
EXISTING EQUIPMENT TO BE REMOVED AND CIRCUIT PULLED BACK
EXISTING EQUIPMENT TO BE REMOVED AND RELOCATED
NEW LOCATION OF RELOCATED EXISTING EQUIPMENT
TO NEXT ACTIVE OUTLET/BACK TO PANEL
EXISTING EQUIPMENT TO REMAIN
WEATHERPROOF
POLYVINYL CHLORIDE CONDUIT
PLUMBING CONTRACTOR
TYPICAL
SOLID NEUTRAL
SWITCHBOARD
MAIN LUGS ONLY
NUMBER
NOT TO SCALE
MOUNTING
MOUNTED
KILOVOLT-AMPERE
MAIN CIRCUIT BREAKER
KILOWATT
LIGHTING
JUNCTION BOX
HEATING, VENTILATING AND AIR CONDITIONING
GENERAL CONTRACTOR
INTERRUPTING CAPACITY
GROUND FAULT INTERRUPTER
HORSEPOWER
GROUND
ELECTRIC METALLIC TUBING
ELECTRICAL CONTRACTOR
DRAWING
AUTOMATIC TRANSFER SWITCH
CIRCUIT BREAKER
COPPER
CENTERLINE
CONDUIT
CIRCUIT
ABOVE FINISHED FLOOR
GROUND FAULT EQUIPMENT PROTECTION
THERMAL SWITCH
MOTOR STARTER
VARIABLE FREQUENCY DRIVE
DISCONNECT SWITCH
FUSED DISCONNECT SWITCH
FLEXIBLE CONNECTION
REQUIREMENTS WITH TELECOMMUNICATIONS CONTRACTOR. REFER TO DETAIL ON DRAWING E0.02.SYSTEMS FURNITURE TELECOMMUNICATIONS PATHWAY. COORDINATE TELECOMMUNICATIONS
SYSTEMS FURNITURE POWER FEED. INSTALL SYSTEMS FURNITURE "WHIP" BY OTHERS.REFER TO DETAIL ON DRAWING E0.02.
AT COLUMN TO ABOVE HUNG CEILING.
(2) 3/4"C. (TEL/DATA) IN FLOOR BELOW TO NEAREST COLUMN. RISE UP
EQUAL TO WIREMOLD #RC4ATC-COM75 WITH (1) 1/2"C. (POWER) AND
FIRE RATED POKE-THRU WITH DOUBLE DUPLEX RECEPTACLE AND TELE/DATA FITTING
DUPLEX TELEVISION RECEPTACLE AND TEL/DATA OUTLET. COORDINATE MOUNTING HEIGHTWITH ARCHITECT. LEVITON #689 20A-125V.
"RS" DENOTES ROOM SCHEDULING DEVICE. MOUNTING HEIGHT 4'-0" AFF.
CEILING MOUNTED DUPLEX RECEPTACLE.
CEILING MOUNTED TELEPHONE/DATA OUTLET.
MULTISERVICE FIRE-RATED FLUSH POKE-THRU WITH (2) 20A-125V-2P-3W DUPLEXRECEPTACLES, PROVISIONS FOR TELECOMMUNICATIONS JACKS AND A/V CONNECTIONS EQUAL TOWIREMOLD #8AT. PROVIDE (1) 3/4"C. (POWER), (1) 1"C. (DATA), AND (2) 1 1/4"C. (A/V AND DATA)
AND RACEWAY REQUIREMENTS WITH A/V AND COMMUNICATIONS CONSULTANTS. CONFIRM FLANGE ANDCOVER COLORS AND FINISHES WITH ARCHITECT. COORDINATE ALL LOCATIONS WITH ARCHITECT AND
TO RUN UNDERSLAB TO ABOVE ACCESSIBLE CEILING. CONFIRM A/V AND COMMUNICATIONS CONNECTIVITY
STRUCTURAL. ALL A/V FLOORBOXES SHALL BE REVIEWED WITH ARCHITECT AND A/V CONSULTANTONCE FURNITURE FOR CONFERENCE ROOMS HAS BEEN SELECTED TO DETERMINE IF A/V POKE-THRUOR FLOOR CORE WITH CONDUITS TO BE USED.
MULTISERVICE FIRE-RATED FLUSH POKE-THRU WITH (2) 20A-125V-2P-3W DUPLEXRECEPTACLES, PROVISIONS FOR TELECOMMUNICATIONS JACKS AND A/V CONNECTIONS EQUAL TOWIREMOLD #6AT. PROVIDE (1) 3/4"C. (POWER), (1) 1"C. (DATA), AND (1) 1 1/4"C. (A/V AND DATA)
AND RACEWAY REQUIREMENTS WITH A/V AND COMMUNICATIONS CONSULTANTS. CONFIRM FLANGE ANDCOVER COLORS AND FINISHES WITH ARCHITECT. COORDINATE ALL LOCATIONS WITH ARCHITECT AND
TO RUN UNDERSLAB TO ABOVE ACCESSIBLE CEILING. CONFIRM A/V AND COMMUNICATIONS CONNECTIVITY
STRUCTURAL.
LOW VOLTAGE MOMENTARY CONTACT SWITCH EQUAL TO LUTRON
QSWS2-*B. MOUNTING HEIGHT 48" AFF. Z# INDICATES ZONE NUMBER.
*E.C SHALL COORDINATE QUANTITY OF BUTTONS WITH ZONE
REQUIREMENTS AND LABEL ALL BUTTONS WITH AREA BEING SERVED.
E.C. SHALL COORDINATE DEVICE COMPATIBILITY WITH LIGHTING
CONTROL PANEL.
LIGHTING CONTROL PANEL EQUAL TO LUTRON XP SERIES. REFER TO
LCP SCHEDULES ON DRAWING E009, E010, AND E011 FOR
QUANTITIES OF RELAYS REQUIRED. 5.
4.
3.
2.
1. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING
THE INTEGRITY AND CONDITION OF THE EXISTING BRANCH CIRCUIT WIRING
WHICH IS TO BE REUSED FOR NEW EQUIPMENT CIRCUITING ACCORDING
TO THE NATIONAL ELECTRIC CODE. ALL DAMAGED WIRING OR WIRINGFOUND TO BE NONFUNCTIONAL SHALL BE REPLACED.
EXISTING BRANCH CIRCUITS SHALL BE EXTENDED AND CONNECTED TO
ALL EXISTING RELOCATED EQUIPMENT, AS REQUIRED FOR A COMPLETEWORKING SYSTEM.
RECONNECT ALL EXISTING CIRCUITING WHICH ORIGINATES OR PASSES
THROUGH THE RENOVATED AREAS BUT SERVES OTHER AREAS NOT BEING
RENOVATED. EXTEND THESE CIRCUITS AS MAY BE NECESSARY TO THE
EXISTING PANELBOARDS. UTILIZE SPARE CIRCUIT BREAKERS.
DEMOLITION WORK SHALL BE DONE BY THE ELECTRICAL CONTRACTOR.
THE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL WORK CONCERNING
EXISTING EQUIPMENT AND SERVICES REMAINING IN THE BUILDING.
THE ELECTRICAL CONTRACTOR SHALL RETURN ALL REMOVED EXISTING
EQUIPMENT TO THE OWNER AT A LOCATION DESIGNATED BY THE OWNER.
22. ALL 120V SINGLE PHASE CIRCUITS SHALL HAVE DEDICATED NEUTRALS.
NO SHARED NEUTRALS SHALL BE ALLOWED EXCEPT FOR FURNITUREFEEDS.
23. WHERE SINGLE POLE BREAKERS ARE SPECIFIED, OR REUSED, TO PROTECT
MULTIWIRE BRANCH CIRCUITS SERVING SINGLE PHASE LOADS, PROVIDE
IDENTIFIED HANDLE TIES PER NEC 240.15(B)(1).
24. ALL ELECTRICAL EQUIPMENT SHALL BE MOUNTED AT THE FOLLOWING HEIGHTS UNLESS
NOTED OR DETAILED OTHERWISE ON THE ELECTRICAL DRAWINGS OR ARCHITECTURAL
DRAWINGS. NOTES OR DETAILS ON THE ARCHITECTURAL DRAWINGS PERTAINING TO
MOUNTING HEIGHTS OR LOCATIONS OF ELECTRICAL EQUIPMENT SHALL SUPERSEDE
THOSE NOTED OR DETAILED ON THE ELECTRICAL DRAWINGS. IF THE MOUNTING HEIGHT
OF ANY ELECTRICAL COMPONENT IS QUESTIONABLE, OBTAIN A CLARIFICATION FROM THE
ARCHITECT BEFORE INSTALLATION. ALL MOUNTING HEIGHTS SHALL COMPLY WITH THE
FEDERAL ADA (AMERICANS WITH DISABILITIES ACT) AND THE STATE OF MASSACHUSETTS
PUBLICATION 521 CMR: ARCHITECTURAL BARRIERS BOARD FOR (BUILDINGS, FACILITIES,
ETC. FOR THE VISUALLY AND PHYSICALLY HANDICAPPED).
REFLECTED CEILING PLANS FOR ANY AND ALL AREAS PREPARED BY THE ARCHITECT
SHOWING THE LOCATION OF LIGHTING FIXTURES SHALL TAKE PRECEDENCE OVER THE
LOCATIONS OF SAME SHOWN ON THE LIGHTING PLANS OF THIS CONTRACT SET OF
ELECTRICAL DRAWINGS. INSTALL THE LIGHTING FIXTURES IN ANY GIVEN AREA TO AGREE
WITH THE ARCHITECT'S REFLECTED CEILING PLANS. WHERE QUANTITIES OF LIGHT
FIXTURES SHOWN ON THE ARCHITECTURAL DRAWINGS DEVIATE FROM THOSE SHOWN ON
ELECTRICAL DRAWINGS, THE CONTRACTOR SHALL NOTIFY ARCHITECT.
25.
3-POSITION, MOTOR CONTROL SWITCH, BY OTHERS. PROVIDE
SINGLE-GANG OUTLET BOX MOUNTED 48" AFF WITH 3/4" EMPTY
CONDUIT, WITH PULL STRING, RUN IN WALL UP TO 6" ABOVE
ACCESSIBLE CEILING AND TERMINATE WITH PLASTIC BUSHING. E.C.
SHALL WIRE DEVICE AS DIRECTED BY MANUFACTURERS
INSTRUCTIONS AND WIRING DIAGRAMS.
PS
FOR CONNECTION TO MOTORIZED PROJECTION SCREEN. SEE ARCHITECTURALDETAILS AND ELEVATIONS FOR EXACT LOCATIONS. COORDINATE FINALCONNECTION REQUIREMENTS WITH MANUFACTURER INSTRUCTIONS.
WS
FOR CONNECTION TO MOTORIZED WINDOW SHADES. SEE ARCHITECTURALDETAILS AND ELEVATIONS FOR EXACT LOCATIONS. COORDINATE FINALCONNECTION REQUIREMENTS WITH MANUFACTURER INSTRUCTIONS.
L431-1
E211-1
EMERGENCY LIGHTING POWER TRANSFER SWITCH. DEVICE SHALL
BE UL LISTED FOR 924 AND 1008 STANDARDS AND LISTED FOR
FIELD INSTALLATION. EQUAL TO BODINE GTD20A.
SEE DETAIL ON DWG. E0.02.
WALL MOUNTED LOW-VOLTAGE VACANCY SENSORSWITCH (MANUAL ON). MOUNTING HEIGHT 48" AFF.DEVICE SHALL BE EQUAL TO LUTRON #MS-A102.
MOUNTED.FLUORESCENT FIXTURE, CEILING SURFACE, RECESSED PENDANT OR WALL
EXIT LIGHTING FIXTURE CEILING, WALL. ARROWS AS INDICATED ON PLAN
(CONSTANT "ON"). E.C. SHALL PROVIDE BY-PASS RELAY ON SWITCHED EMERGENCY
LIGHTING FIXTURE ON NORMAL/EMERGENCY CIRCUIT. "NL" DENOTES NIGHT LIGHT
CIRCUITS.
STANDARD DESIGNATION FOR ALL LIGHTING FIXTURES. "A", "C" INDICATESFIXTURE TYPE; "3" INDICATES CIRCUIT NUMBER, "a" INDICATES SWITCH CONTROL,"Z#" INDICATES LIGHTING ZONE NUMBER.
FLOOR
REFER TO ARCHITECT'S REFLECTED CEILING PLAN,DRAWINGS, AND SPECIFICATIONS FOR LIGHTINGFIXTURE TYPES AND LAYOUT.
COPPER GROUND BUS
A/V
P FLANGE AND COVER FINISH BY ARCHITECT. INSTALL SYSTEMS FURNITURE "WHIP" BY OTHERS.SYSTEMS FURNITURE FIRE-RATED POKE-THRU POWER AND TEL/DATA FEED. WALKER #4FFATC.
REFER TO DETAIL ON DRAWING E0.02.
T/D
A/V6
OTHERWISE NOTED.AWG SIZE AS NOTED, XHHW INSULATION, 600 VOLTS RATED, UNLESSALL FEEDER CONDUCTORS SHALL BE 98% CONDUCTIVITY, COPPER,
17.
16.
14.
15.
21.
75/90°C INSULATION, 600 VOLTS RATED, UNLESS OTHERWISECOPPER, MINIMUM #12 AWG SIZE, THWN/THHN WITH DUAL RATEDALL BRANCH CIRCUIT CONDUCTORS SHALL BE 98% CONDUCTIVITY,
20.
19.
NOTED. 120 VOLT 20 AMP BRANCH CIRCUITS OF MORE THAN 75 FEET
18.
ALTHOUGH ALL BRANCH CIRCUIT WIRE AND CONDUIT IS NOT SHOWN,
13.
IT IS THE INTENT OF THESE DOCUMENTS THAT A COMPLETE BRANCH
CIRCUIT WIRING SYSTEM BE INSTALLED.
ALL SWITCH CONTROLS SHALL BE PROVIDED WITH WIRING AND
INDICATED WITH CIRCUIT NUMBERS AND PANEL DESIGNATIONS.
WIRING AND CONDUIT SHALL BE REQUIRED BETWEEN ALL OUTLETS
WIRING SHOWN ON DRAWINGS ONLY FOR SPECIFIC ROUTES OR
CONDUIT AS REQUIRED.
SPECIAL CONDITIONS.
ALL ELECTRICAL WORK SHALL BE RECESSED INTO WALLS OR RUN ABOVETHE HUNG CEILING WHERE POSSIBLE.
BACK-TO-BACK RECEPTACLES, SWITCHES, TELEPHONE OUTLETS, ETC.WILL NOT BE ACCEPTABLE.
CABLE, SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE.A GROUNDING CONDUCTOR SHALL BE INCLUDED IN EACH RACEWAY OR
AND 277 VOLT 20 AMP BRANCH CIRCUITS OF MORE THAN 150 FEETFROM CENTER OF LOAD TO PANEL SHALL BE #10 AWG.
IN WORKING IN THESE AREAS.TO EXISTING UTILITY LINES AND/OR HARM TO PERSONNEL ENGAGEDTHE ELECTRICAL CONTRACTOR SHALL USE CAUTION TO AVOID DAMAGE
BY THE HVAC OR PLUMBING CONTRACTOR.REQUIRED STARTERS AND DISCONNECTS WHICH ARE NOT FURNISHEDTHE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL CODE
REQUIRED. I.E. POWER, CONTROLS, INTERLOCKS, ETC.EQUIPMENT AND SHALL MAKE ALL FINAL POWER CONNECTIONS ASTHE EXACT LOCATIONS AND ROUGHING IN DIMENSIONS OF ALLPLUMBING CONTRACTORS AND MANUFACTURERS SHOP DRAWINGS FOR
11.
12.
THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE HVAC AND
CONTINUOUS THROUGH CIRCUIT.WIRE AND CONDUIT SIZE INDICATED ON HOMERUNS SHALL BE
SUPPORTED FROM THE BUILDING STRUCTURE.RIGID STEEL CONDUIT AND ELECTRICAL METALLIC TUBING SHALL BE
NATIONAL ELECTRICAL CODE AND LOCAL GOVERNING AUTHORITIES.ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH OSHA, THE
CONNECTIONS TO MOTORS AND VIBRATING EQUIPMENT.FLEXIBLE METAL CONDUIT SHALL BE USED FOR ALL FINAL
1/2" C. UNLESS SUBJECT TO INJURY, THEN RIGID STEEL.ROOMS, MECHANICAL ROOMS, ETC.): SHALL BE E.M.T. MINIMUM SIZEEXPOSED IN NON-FINISHED ROOMS (I.E. STORAGE ROOMS, ELECTRIC
GROUND CONDUCTORS.METAL CLAD CABLE (MC) WITH FULL SIZE INSULATED GREENCONCEALED ABOVE HUNG CEILINGS AND IN WALLS SHALL BE
BRANCH CIRCUITS SHALL BE INSTALLED IN THE FOLLOWING RACEWAYS:
COMPLETE AND READY FOR OPERATION.DENTAL ACCESSORIES NECESSARY TO MAKE THE ELECTRICAL WORKTHE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL INCI-
MENTS INDICATED.NOT BE LIMITED TO, ALL ELECTRICAL POWER AND CONTROL REQUIRE-THE ELECTRICAL CONTRACTORS' SCOPE OF WORK SHALL INCLUDE, BUT
COORDINATED WITH THE EQUIPMENT REQUIREMENTS AND FIELDHEIGHTS OF EQUIPMENT AND ROUTING OF RACEWAYS SHALL BEDRAWINGS ARE DIAGRAMMATIC ONLY. EXACT LOCATIONS, MOUNTING
CONNECTIONS AND COORDINATE WITH OTHER TRADES.ALL CONTRACT DOCUMENTS, FOR ALL TRADES, MAKE ALL EQUIPMENTTHE ELECTRICAL CONTRACTOR SHALL FAMILIARIZE HIM/HERSELF WITH
SUBMISSION OF BID PRICES.ALL PRE-EXISTING CONDITIONS AND WORK NECESSARY PRIOR TOTHE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO DETERMINE
9.
10.
7.
8.
6.
c.
b.
a.
CONDITIONS.
5.
4.
3.
2.
1.
THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LIGHTING FIXTURES
COMPLETE WITH MOUNTING ACCESSORIES TO MEET JOB REQUIREMENTS.
THE ELECTRICAL CONTRACTOR SHALL VERIFY FIXTURE MOUNTING AND
LOCATION AGAINST ARCHITECTURAL REFLECTED CEILING PLANS,
ELEVATIONS AND DETAIL DRAWINGS. EXACT LOCATION OF ALL FIXTURES
SHALL BE CONFIRMED WITH THE ARCHITECT PRIOR TO ROUGHING IN.
SERIES FIXTURES SHALL SATISFY LENGTHS AS SHOWN ON THE DRAWINGS.
FIXTURE LETTERS SHOWN ONCE ON A CONTINUOUS ROW OF FIXTURES
SHALL BE TYPICAL FOR THAT ROW UNLESS OTHERWISE NOTED.
ALL FIXTURES SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE,
INDEPENDENT OF HUNG CEILINGS.
MANUFACTURERS CATALOG NUMBERS ARE SHOWN FOR REFERENCE
PURPOSES ONLY. THEY ARE MEANT TO PROVIDE A GENERAL DESCRIPTION
OF THE DESIGN AND QUALITY OF FIXTURES REQUIRED. EQUIVALENT
PRODUCTS, BY OTHER MANUFACTURERS, WILL BE CONSIDERED.
ALL INCANDESCENT LAMPS SHALL BE RATED 130 VOLTS UNLESS
OTHERWISE SPECIFIED.
ALL FLUORESCENT LAMPS SHALL BE ENERGY SAVING TYPE.
ALL FLUORESCENT FIXTURES SHALL HAVE ENERGY SAVING ELECTRONIC BALLASTS-
U.L. APPROVED AS A COMBINATION WITH ENERGY SAVING LAMPS SUPPLIED.
REFER TO LIGHTING FIXTURE SCHEDULE OR PROJECT ELECTRICAL SPECIFICATIONS
FOR FIXTURE DESIGNATIONS, SPECIFICATIONS, VOLTAGE AND LAMP REQUIREMENTS.
THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING COMPATIBILITY
BETWEEN ALL FLUORESCENT DIMMING BALLASTS, LED DRIVERS, AND DIMMING SYSTEMS/
SWITCHES INCLUDED IN THE PROJECT SCOPE. THE LIGHTING SUBMITTAL PACKAGE SHALL
INCLUDE ALL STANDALONE DIMMING SWITCH AND/OR CENTRAL DIMMING SYSTEM PRODUCT
DATA AND A WRITTEN STATEMENT THAT ALL COMPONENTS HAVE BEEN CERTIFIED AS
COMPATIBLE BY THE MANUFACTURERS OF THE INTERCONNECTED COMPONENTS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02218Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NOT FOR CONSTRUCTION
AHA Consulting Engineers24 Hartwell Avenue, 3rd FloorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
N.T.S.
4/8
/2019
2:5
0:3
2 P
M
E0.00179-18-00
04/08/19
ELECTRICAL LEGEND ANDNOTES
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
Issuance Schedule
Number Date Description
2 SETS OF 3-250kcmil &
2-250kcmil (NEUTRAL) & 1#3G
2-400kcmil (NEUTRAL) & 1#2G
2 SETS OF 3-400kcmil &
2-400kcmil (NEUTRAL) & 1#1/0G
3 SETS OF 3-400kcmil &
2-500kcmil (NEUTRAL) & 1#1G
2 SETS OF 3-500kcmil &
2 SETS OF 3#4/0 & 2#4/0
(NEUTRAL) & 1#3G
FEEDER SIZE SCHEDULE (COPPER CONDUCTORS) 200% FEEDER SIZE SCHEDULE (COPPER CONDUCTORS)"K" RATED TRANSFORMER SCHEDULE
EXISTING LIGHTING CONTROL PANEL
SCHEDULE: LCP12
PANELBOARD SCHEDULE
4-250 kcmil & 1#4G.
4-350 kcmil & 1#4G.
4-500 kcmil & 1#3G.
4-600 kcmil & 1#3G.
2 SETS OF 4-350 kcmil & 1#1G.
2 SETS OF 4-250 kcmil & 1#2G.
2 SETS OF 4-600 kcmil & 1#1/0G.
3#4/0 & 1#4G.
3-350 kcmil & 1#4G.
3-250 kcmil & 1#4G.
3-500 kcmil & 1#3G.
2 SETS OF 3-250 kcmil & 1#2G.
2 SETS OF 3-350 kcmil & 1#1G.
3-500 kcmil & 1#3G.
2 SETS OF 3-600 kcmil & 1#1/0G.
24
25
27
29
30
28
26
21
23
19
17
15
22
20
16
18
14
2-2 1/2"
2-3 1/2"
2-3"
3"
3 1/2"
3"
2 1/2"
2 1/2"
3#6 & 1#10G.
3#3 & 1#8G.
3#1 & 1#6G.
3#1/0 & 1#6G.
3#2/0 & 1#6G.
3#4 & 1#8G.
3#3/0 & 1#6G.
3
13
11
9
7
5
12
10
8
6
4
1
2
1"
1 1/2"
2"
1 1/2"
1 1/2"
1 1/4"
3/4"
200
2-4"
2-3"
2-3"
4#3/0 & 1#6G.
4#4/0 & 1#4G.
4"
4"
3"
2 1/2"
3"
2"
800
600
500
350
400
300
250
225
4#1 & 1#6G.
4#1/0 & 1#6G.
4#2/0 & 1#6G.
4#4 & 1#8G.
4#3 & 1#8G.
1 1/2"
2"
2"
1 1/4"
1 1/4"
4#6 & 1#10G. 1"
175
150
100
125
70
60
30a
200
3-3 1/2"
2-3 1/2"
2-3"
800
600
500
350
400
300
250
225
175
150
100
125
70
60
3"
3 1/2"
3-300 kcmil & 2-300 kcmil
(NEUTRAL) & 1#4G
3-350 kcmil & 2-350 kcmil
(NEUTRAL) & 1#4G
3#1 & 1#4/0 (NEUTRAL)2"
2 1/2"
2 1/2"
& 1#6G
3#2/0 & 2#2/0 (NEUTRAL)
3#3/0 & 2#3/0 (NEUTRAL)
& 1#6G
& 1#8G
28a
26a
24a
22a
20a
18a
16a
14a
12a
10a
8a
6a
4a
2a
2-4"
2-2 1/2"
4"3-500 kcmil & 2-500 kcmil
(NEUTRAL) & 1#4G
3"3-250 kcmil & 2-250 kcmil
(NEUTRAL) & 1#6G
2 1/2"3#4/0 & 2#4/0 (NEUTRAL)
& 1#6G
3#3 & 1#2/0 (NEUTRAL)1 1/4"
& 1#8G
3#4 & 1#1/0 (NEUTRAL)1 1/4"
& 1#10G1#8-1/2"
1#8-1/2"
1#2-1/2"
1#6-1/2"
1#1/O-3/4"
1#2/O-3/4"
1#1/O-3/4"
1#3/O-3/4"
1#3/O-3/4"
42 3P
833P
30A- 3#10&1#10G.
50A- 3#8&1#10G.-3/4"C.
-1/2"C.
208
1253P
250A-
313400A-
-1"C.
125A-
80A-
3#1&1#6G.-1 1/2"C.
3#4&1#8G.
-2"C.
200A- 3#3/0&1#6G.
18T2A15
36T3AK-13
30
K-13
90
54
T5A
T4A
75
K-13
K-13
136T6AK-13
112.5
45
625
417500A-
800A-
8331000A-
400A-
250A-
3-500kcmil &
1#4G.-2 1/2"C.
3-250kcmil &
1#2G.-3"C.
500A-3-250kcmil &2 SETS OF
1#3G.-3"C.
13881600A-800A-
3-500 kcmil &2 SETS OF
1#1/0G.-3"C.
271
182
T8A
T7A150
K-13
225
361T9A300
K-13
K-13
602T10AK-13
500
NOTE:
ISOLATED GROUND CONDUCTOR EQUAL TO EQUIPMENT GROUND.
3-350kcmil &
3-600kcmil &
1#1/0 G.-4"C.
2-600kcmil (NEUTRALS)
2 SETS OF3-400kcmil &
(NEUTRAL)1#1/0G.-3 1/2"C.
1#2G.-3"C.
2 SETS OF
2-350kcmil
(NEUTRAL)
3-250kcmil &
1#2G.-3 1/2"C.
1#6G.-2"C.
(NEUTRALS)
3#3/0 & 2#3/0
1#4G.-2 1/2"C.
1#8G.-1 1/4"C.
3#6 & 2#6
3#1 & 2#1
& 2-600 kcmil (NEUTRALS)1#1/0 G.-4"C.
600 kcmil
WHEN ISOLATED GROUND CONDUCTOR IS REQUIRED, PROVIDE AN1.
3P
3P
3P
3P
3P
3P
3P
3P
3P 3P
3P
3P
3P
3P
3P
150A-
100A-
50A-
3 SETS OF
5 SETS OF
(NEUTRAL) 2-400kcmil
1#1/0G.-3 1/2"C.
3-400kcmil &3 SETS OF
2-400kcmil
2-250kcmil
(NEUTRALS)
(NEUTRALS)
(NEUTRALS)
400 kcmil
250 kcmil
#3/0
#2/0
#1/0
#2
#4
#6
#8
(2) 20A-1P;
(5) 20A-1P; SEE NOTE 1.
PROVIDED WITH 200% NEUTRAL
AND FEED THRU LUGS.
SEE NOTE 1.
(66) 20A-1P;PROVIDED WITH 200% NEUTRAL
AND FEED THRU LUGS.
SEE NOTE 1.
CONDUCTORS (3 PHASE,
4 WIRE) WITH GROUND
CONDUCTORS (3 PHASE,
3 WIRE) WITH GROUNDSYMBOL
FEEDER CONDUIT
SIZE
CONDUIT
SIZE AMPERE RATING
NOMINAL CONDUCTORS (3 PHASE,
4 WIRE) WITH GROUNDSYMBOL
FEEDER CONDUIT
SIZE AMPERE RATING
NOMINALPROT.O.C.SEC.
FEEDERO.C.
PROT. AMPSAMPSPRI.SIZE KVA
480V. PRIMARY 208/120V.Y SECONDARY
SUPPLY SIDE
CONDUCTORS & COND.
GROUNDING
ELECTRODECONDUCTOR & COND.
MAINBONDING
JUMPER
ZONE # RELAY # DESCRIPTION CIRCUIT
ACTIVE
BRANCH CIRCUIT BREAKERSMAINSVOLTAGEPANEL MTGMCB
MLO/
SPARE 1 P.SPACES
(RMS)A.I.C.
REMARKS
PARTIAL POWER DISTRIBUTION RISER DIAGRAMN.T.S.
L4121
208/120V, 3Ø, 4W S
S
400A 250A
225A -
- -
65K
22K
[XM]- -
P2121[XM]
480/277V, 3Ø, 4W
208/120V, 3Ø, 4W S400A - - - 10KP2122[XM]
PANELBOARD SCHEDULE NOTES:
1. E.C. SHALL UTILIZE EXISTING SPACES AND CIRCUIT BREAKERS AS REQUIRED AND RECONFIGURE PANEL AS NECESSARY TO
ACCOMMODATE NEW CIRCUIT BREAKERS. NEW CIRCUIT BREAKERS AIC RATING SHALL MATCH EXISTING DISTRIBUTION.
*DENOTES GFCI TYPE CIRCUIT BREAKER.
**DENOTES HACR TYPE CIRCUIT BREAKER.
NEW ELECTRICAL EQUIPMENT.
EXISTING ELECTRICAL EQUIPMENT TO REMAIN
NOTES:
UNLESS OTHERWISE NOTED
12
1313
12
L4121LCP12
T7A
P2121P2122
2500A, 277/480V.,3PH, 4W, BUSDUCT CN1 [XM](100K AIC)
BD
400A250A
400A200A
400A250A
XM XM
XM
XM XM
XM
XM
XM
8
6
7
2
3
4
5
2
3
1 1
9
10
11
12
13
14
15
16
18
17
CORRIDORS
ELEVATOR LOBBY 1201
OPEN OFFICE
OPEN OFFICE
OPEN OFFICE
KITCHENETTE 12015
OPEN OFFICE
OPEN OFFICE
18
8
6
7
4
5
9
10
11
12
13
14
15
16
17
INNOVATION 12074 &
INNOVATION 12053, 12040
19 KITCHENETTE 1201519
20 20
21 21ELEVATOR LOBBY 1201
22-32 SPARE --
L4121-1
L4121-1
L4121-1
L4121-5
L4121-5
L4121-5
L4121-5
L4121-5
L4121-5
L4121-1
L4121-1
(EXISTING)
(EXISTING)
(EXISTING)
(EXISTING)
(EXISTING)
(EXISTING)
(EXISTING)
(EXISTING)
(EXISTING)
(EXISTING)
(EXISTING)
(EXISTING)
OPEN OFFICE
OPEN OFFICE
OPEN OFFICE
OPEN OFFICE CORRIDOR
NEW CORRIDOR
SPARE
SPARE
L4121-13
L4121-13
E4131-4
L4121-7(NEW)
L4121-1
-
-
OPEN OFFICE
OPEN OFFICE E4131-4
L4121-7
L4121-7(EXISTING)
(EXISTING)
(EXISTING)
(EXISTING)
(EXISTING)
(EXISTING)
(NEW)
(EXISTING)
(EXISTING)
12067 (DECORATIVE)
12075
& 12034 (DECORATIVE)
12046
12033
12046
(DECORATIVE)
(DECORATIVE)
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02218Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NOT FOR CONSTRUCTION
AHA Consulting Engineers24 Hartwell Avenue, 3rd FloorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
N.T.S.
4/8
/2019
2:5
0:3
2 P
M
E0.01179-18-00
04/08/19
ELECTRICAL SCHEDULESAND RISER DIAGRAM
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
NOTES:1. REFER TO ARCHITECTURAL PLANS FOR EXACT LENGTHS OF CONTINUOUS ROWS.
BUILDING B - 12TH FLOOR CALL CENTER - LIGHTING FIXTURE SCHEDULE
TYPE MTG DESCRIPTION MANUF. CATALOG NO.
LAMPS
VOLT REMARKSNUM. TYPEFB8 PENDANT 8' FLUORESCENT DIRECT/INDIRECT PENDANT
W/ FLUSH LENS (TO MATCH EXISTING)CORELITE E2-WW-2N5-1C-UNV-AC48"-(CEILING)-8' 4 F28T5/830/ ECO 277 V
FD RECESSED 6" OPEN APERTURE FLUORESCENTDOWNLIGHT (RELOCATED)
PORTFOLIO C6142E-6151LIWF 1 CF26DT/E/IN/830/ECO 277 V
FJ4 RECESSED 4' FLUORESCENT FIXTURE W/ DIAGONALLYSTAGGERED LAMP (RELOCATED/TO MATCHEXISTING)
AMERLUX GRUV6-GRID-1T5-E-HW-120/277V-4'-1.0BF 1 FP28/830/ ECO 277 V
FL RECESSED 2X2 FLUORESCENT LENSED TROFFERFIXTURE
CORELITE R2-WL-2N5-1C-UNV-22-T1 2 FP14/830/ ECO 277 V
X1 UNIVERSAL EDGE-LIT LED EXIT SIGN SURE LITES ELX6*00R 1 LED 277 V NUMBER OF FACES AND DIRECTIONALARROWS AS REQUIRED.
Issuance Schedule
Number Date Description
RECEPTACLE
TELEPHONE AND/ORDATA OUTLET
2"48"
18"
DUPLEX
J.B. FOR INTERFACING
2-GANG BOX AND 2-GANG
TELE/DATA CABLING.BUSHED OPENING FORCOVER PLATE WITH 2"
BASE FEED MODULES
COMMUNICATIONS(TELEPHONE & DATA)
INSTALLED BY E.C.EQUIPMENT SUPPLIER
POWER
POWER WHIP BY
WITH WORK STATION
EC SHALL FURNISH &
FOR TELEPHONE ANDINSTALL PULL STRINGS
DATA SYSTEMS
ABOVE HUNG CEILING
SECURE PULL STRINGS
HUNG CEILINGTO BAR JOISTS ABOVE
JUNCTION BOX MOUNTED
WORK STATION
8#10-3/4"FLEXIBLE METALCONDUIT FISHED IN WALLOR COLUMN
HUNG CEILING
HOMERUN TO PANELBOARD.
FOR PANEL AND CIRCUIT NUMBERSTO POWER PANEL, REFER TO FLOOR PLANS4#10(∅), 2#10(N.), 2#10G., 1"C.
LCP#A
Load Center
XXXLOW VOLTAGEOVER-RIDE SWITCH.(TYPICAL FOR EACHZONE),
TO NEXT LIGHTING CONTROLPANEL OR MASTERCONTROLER AS REQUIRED.
1/2"C. AND WIRINGAS REQUIRED
* Lig
htin
g C
on
trol Z
one
s
NTSTYPICAL DEVICEMOUNTING DETAIL
LIGHTING CONTROL SYSTEMONE-LINE DIAGRAM NTS
FURNITURE SYSTEM CONNECTIONDETAIL (4-CIRCUIT, 8-WIRE) NTSNTS
FIRE RATED POKE-THRU FURNITURE SYSTEMCONNECTION DETAIL (4-CIRCUIT, 8-WIRE) NTS
EMERGENCY LIGHTING BYPASS RELAY(EMERGENCY LIGHTS FED FROM TENANT POWER)
SMC
NOTES:
1. WHERE POSSIBLE, E.C. SHALL ALLIGN DEVICES WITH FIRE ALARM DEVICES AND THERMOSTATS
NOTES:
1. * MOMENTARY SWITCH TERMINATIONS ARE PROVIDED PANEL. PROVIDE CONTROL WIRE PER MANUFACTURER'S
RECOMMENDATIONS. * REFER TO LCP SCHEDULES FOR QUANTITIES OF RELAYS.
2. COORDINATE WITH SYSTEM MANUFACTURER TO PROVIDE ADDITIONAL CONNECTIONS AND ACCESSORIES AS REQUIRED TO
INSTALL A COMPLETE OPERATIONAL SYSTEM.
FINISHED FLOOR
ALIGN DEVICES ON COMMON
SPANS. DO NOT ALIGN ON STUDS.CENTERLINES, UTILIZE STUD
LIGHTING
SWITCH
WALL STUDS
SEE NOTE #1
ABOVE HUNG CEILING OF
HOMERUN TO PANELBOARD. PROVIDE 5'-0" OF
FLEXIBLE CONDUIT SLACK FOR REMOVAL OF
POKE-THRU DEVICE FROM FLOOR ABOVE.
BELOW FINISHED FLOORDOTTED INDICATES
JUNCTION BOXES MOUNTED
FLOOR BELOW (TYPICAL)
AND DATA SYSTEMS.
ELECTRICAL CONTRACTOR SHALL
PULL STRINGS FOR TELEPHONEFURNISH AND INSTALL 1-1/4"C. &
FINISHED FLOOR
WIREMOLD #4FFATCPOKE-THRU EQUAL TOPOWER/TEL/DATA
LIQUID TIGHT POWER WHIPBY FURNITURE MANUFACTURER.INSTALLED BY E.C.
COMMUNICATIONS
BY OTHERS.(TELE/DATA)
ELECTRIFIED FURNITURE
SYSTEM PARTITION.
POWER
FOR PANEL AND CIRCUIT NUMBERS
POWER PANEL, REFER TO FLOOR PLANS
4#10(∅), 2#10(N.), 2#10G., 1"C. TO
UL 924 AND UL 1008 EMERGENCY LIGHTING RELAY CONTROL DEVICE WITH RELAY SWITCHING CIRCUITRY, A TEST
SWITCH, A NORMAL POWER INDICATOR LIGHT AND AN ALTERNATE POWER INDICATOR LIGHT CONTAINED IN ONE 9" X 6" X
3.5" ENCLOSURE. DEVICE SHALL SENSE NORMAL POWER AT 120 THROUGH 277 VAC, 50/60 HZ; SHALL BE RATED FOR 120
THROUGH 277 VAC, 50/60 HZ AT UP TO 20 AMPS OF LIGHTING LOAD. THE DEVICE SHALL BE UL LISTED FOR FIELD
INSTALLATION IN INDOOR OR DAMP LOCATIONS.
VOLTAGE
SENSING
LTG.
LOAD
EMERGENCY
LIGHTING
CIRCUIT
NEUTRAL
NORMALLIGHTINGCIRCUITNEUTRAL
EMERGENCY
LIGHTING
CIRCUIT
HOT
NORMALLIGHTINGCIRCUITHOT
MANUAL SWITCH,
LCP CONTACT OR
DIMMING MODULE
AS APPLICABLE
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02218Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NOT FOR CONSTRUCTION
AHA Consulting Engineers24 Hartwell Avenue, 3rd FloorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
N.T.S.
4/8
/2019
2:5
0:3
3 P
M
E0.02179-18-00
04/08/19
ELECTRICAL DETAILS
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
Issuance Schedule
Number Date Description
I. GENERAL
A. The work covered consists of furnishing all labor and materials necessary to install, complete and ready for continuous operation, the electrical systems, apparatus and equipment for the
renovation.
B. Shop drawings of all specified fixtures, equipment and apparatus shall be submitted to the Architect for approval.
C. Codes: All equipment and materials furnished under the Electrical Sub-Contracts and labor performed herein shall be in complete accordance with the Massachusetts State Building and
Electrical Codes, the City of Boston, National Fire Protection Association and insurance regulations and requirements governing such work.
D. Permits: Any and all permits required for installation of any material shall be obtained as part of the work of the Specification including all fees or expenses incurred.
E. Instructions: During the assembly and installation of all electrical systems, the Owner's operating personnel shall be instructed regarding its operation and maintenance. A two (2) week
instruction period shall be provided after completion of project. Operation and maintenance manuals shall be required.
F. Guarantee: All materials and equipment, furnished and installed, shall be guaranteed in writing for one (1) year from the date of acceptance of the building by the Owner.
G. Record Drawings: The Electrical Subcontractor shall maintain at the job, at all times, a complete and separate set of blackline prints of the Electrical Drawings of his trade on which he shall mark
clearly, neatly, accurately and promptly as the work progresses. As-Builts shall be furnished by the Electrical Subcontractor at the job completion.
H. Inspection: All work shall be subject to the inspection of the Owner, the Architect and such other inspectors having jurisdiction. A properly executed certificate of inspection shall be provided.
I. Tests: The Electrical Subcontractor shall perform all tests at the completion of the work and the results furnished to the Owner and Architect in writing. Tests shall include but not be limited to: all
systems test free of shorts or grounds, proper neutral connections, ground system resistance, secondary voltages at main distribution panel, power panels and lighting panels, all lighting fixtures
with lamps in place for ten (10) hours.
J. Upon completion of all work, the Electrical Subcontractor shall furnish, in duplicate, certificates of inspections from all inspectors and authorities having jurisdiction, notarized letters from the
manufacturers stating that authorized factory engineers have inspected and tested the installation of their respective systems and found same to be in perfect operating condition.
II. SCOPE
A. The work of this Section consists of all labor, materials and equipment required to provide all Electrical work, not specifically described in other trades complete, in place, as shown on the
Drawings, specified herein and as necessary for a proper installation.
B. The extent of the Electrical shall include, but not be limited to the following:
1. Interior secondary normal distribution systems including individually mounted controls, disconnect switches, raceways, cables, wiring, junction and pull boxes, terminal cabinets, wireway and all
other components required for a complete lighting, and power systems.
2. Lighting systems (indoor and exit) including all fixtures, lamps, plaster and tile frames, switches, outlets, wiring raceways and all other components and fittings required for a complete lighting
system.
3. Interior telephone conduit system
4. Power wiring to include connections for heating, ventilating and air conditioning system motors and equipment. All starters and line voltage thermostats will be furnished to the Electrical
Contractor for wiring, connections and mounting.
5. Power, control and alarm wiring to include connections for the Plumbing and Fire Protection Systems Equipment shall be wired and connected by the Electrical Contractor.
6. Grounding and bonding of all electrical systems and equipment.
7. All other systems hereinafter specified or indicated on the Contract Drawings, complete, leaving ready an electrical system in perfect operating condition.
8. Selective demolition.
III. RELATED WORK
A. The following equipment items and work shall be the responsibility of others:
1. Telephone system equipment and instruments are to be furnished and installed by Owner's private telephone company.
2. All automatic temperature control system components, wiring and interlock wiring associated with the heating, ventilating and air conditioning system will be furnished, mounted, wired and
connected by the HVAC Contractor.
3. Finish painting, except factory finished items.
4. Mounting of electrical equipment having mechanical connections. Refer to work involving mechanical trades.
5. Concrete, masonry work including finish painting.
6. Installation, wiring and connecting of automatic temperature controls unless otherwise noted or specified.
7. Starters and control devices for heating, ventilating and air conditioning equipment unless otherwise noted or specified.
8. Starters and control devices for plumbing equipment.
IV. EXISTING MAIN ELECTRIC SERVICE
A. Electrical service is existing and shall be maintained throughout construction.
B. Secondary voltage characteristics for project are 277/480 volt, three phase, 4-wire, 60 cycle and 120/208 volts, three phase, 4-wire, 60 cycle.
V. NAMEPLATES
A. Nameplates shall be furnished and installed on each device of the panelboards, junction boxes, cabinets for special purposes, motor disconnect switches, remote control stations, starters and
other controls furnished under this Contract, to designate equipment controlled and function.
B. Nameplates shall be laminated black bakelite with 1/4-inch-high white recessed letters secured with galvanized screws or rivets.
VI. TEMPORARY POWER AND LIGHT
A. Furnish and install temporary lighting and power required by the trades for construction purposes. The operation and maintenance shall be the responsibility of the General Contractor.
VII. SEISMIC RESTRAINTS
A. Installation of Mechanical and Electrical equipment, accessories and components shall be in accordance with the Seismic Requirements identified in the Massachusetts State Building Code,
Ninth (9th) Edition.
VIII. MATERIALS
A. Wire and Cable:
1. All conductors and installed shall be sized per the Massachusetts Electrical Code.
2. All conductors shall be 98% conductivity copper with 75C/90C dual-rated insulation, #12 through #6 AWG type THHN-THWN; #4 AWG and larger type XHHW, unless otherwise indicated.
Minimum size #12 AWG.
3. All wiring shall be color coded.
4. Flexible metal clad (MC) 90'C rated cable with galvanized steel armor shall have the required number of phase conductors, neutral and full size insulated (green) ground conductor. Conductors
shall be #12 AWG. minimum, type THHN. Aluminum armored cable shall not be used.
B. Raceways and Pull Boxes:
1. All wiring shall be installed in rigid galvanized steel conduit, intermediate steel conduit, or electric metallic tubing whichever is applicable to the Massachusetts Electric Code and sized in
accordance with same.
2. Branch circuit wiring and panelboard homeruns shall be in E.M.T., minimum size 1/2 inch.
3. Metal clad cable with a full size, insulated, separate ground wire may be used as permitted by state and local codes for branch circuit wiring concealed above hung ceilings and in studded
partitions.
4. All wiring for the Fire Alarm System shall be installed in Conduit. E.C. shall furnish and install FA system as specified on Fire Drawings.
5. Set screw connectors shall be galvanized steel.
6. Wireways shall be of the code gauge steel type with hinged and screw covers.
7. Pull boxes shall be of the code gauge galvanized steel with screw covers to match. Pull boxes shall be installed in accordance with the Massachusetts Electrical Code and/or job conditions.
C. Grounding:
1. Grounding shall be in accordance with the Massachusetts Electrical Code.
2. All service fixtures, neutral conductors, metal conduits, supports, motor frames, starters, safety switches and all other metal parts shall be grounded. A complete green ground wire system shall
be installed with all phase conductors in addition to neutral conductor in all feeders and branch circuits.
D. Existing Panelboards - lighting, power and distribution
1. The existing panelboards are suitable for 480/277 volts, three phase, 4 wire and 208/120 volts, three phase, 4 wire operation as previously installed.
2. Where connections are made in existing panelboards, the panel index shall be revised to indicate the new loads served. All existing panelboards that do not have a circuit directory card mounted
in a frame with noncombustible plastic cover shall have one installed on the inside of the door. All directory cards shall be properly filled in, typewritten indicating areas and devices served by
each unit.
3. New circuit breakers added to existing panelboards shall be the same frame size and interrupting capacity as existing panelboard and circuit breakers.
E. Disconnect Switches:
1. Disconnect switches shall be of the fused or unfused type heavy duty, interlocking cover and side operated, rated 480 or 250 volts or as required.
2. Switches shall be horsepower rated, for the voltage of the motor being served. Enclosures shall be NEMA I indoors, NEMA 3R outdoors.
3. Switches shall be General Electric, Seimens or approved equal.
4. Furnish and install disconnect switches for all items of HVAC and plumbing equipment which are not specified as being equipped or furnished with main disconnect devices in the respective
Specification of each piece of equipment.
F. Fuses:
1. Furnish and install the fuses necessary to complete the electrical installation.
2. Unless otherwise noted, fuses shall be general purpose, one time, and cartridge type, UL Class H.
3. Dual element fuses, where indicated (D.E.) shall be current limiting time delay, cartridge type UL Class RK-5, with short circuit interrupting capacity of 200,000 amperes RMS.
4. All secondary system fuses rated at 600 volt or less shall be Underwriters Laboratories, Incorporated approved, be constructed in conformance with the applicable Standards set forth by NEMA
and ANSI. All fuses 600 volt or less shall be manufactured by Bussman, Chase Shawmut or General Electric.
G. Outlet, Junction and Pull Boxes:
1. Furnish and install outlet, junction and pull boxes as specified herein and where shown on the Contract Drawings and at all other locations where they are required to facilitate the pulling,
supporting or connection of wires and cables.
H. Wiring Devices:
1. Switches: General lighting switches shall be 1-pole, 2-pole, 3-way or 4-way and be 20A, 120/277V AC rated as manufactured by Arrow-Hart, Pass&Seynour, Hubbell, Leviton or approved equal.
Coordinate finish with existing devices.
2. Receptacles:
a. Bodies shall be of high impact nylon, color by Architect, unless noted otherwise, supported by mounting yoke having plaster ears and shall be "Specification Grade". Receptacles shall be side or
back wired with two (2) screws per terminal. All receptacles shall be the grounding type and shall be connected to metal mounting yoke. A terminal shall be provided for ground wire on all
receptacles.
b. Convenience duplex receptacles shall be 20 ampere, 125 volts, 2 pole, 3-wire, U-slot grounded type. Manufactured by Crouse Hinds, Pass & Seymour or Hubbell.
c. Special receptacles as specified on the drawings shall have suitable caps and plates or covers.
3. Device Plates:
a. All device plates for toggle switches, receptacles, telephone outlets, pilot lights and miscellaneous devices shall match devices as manufactured by Crouse Hinds, Pass & Seymour or Hubbell.
b. Identification: All devices shall have tags on their cover plate identifying the circuit number and panel feeding them.
I. Telephone/Data System:
1. Furnish and install all conduits, pull strings, boxes, plywood backboards, outlets, fittings and all appurtenances required for a complete system ready for installation of telephones, equipment and
cables of the Telephone/Data Company.
2. All wall and floor outlet plates shall be furnished by the Telephone/Data Company.
3. The Contractor shall consult with the representative of the Owner's Telephone/Data Company and confirm to these requirements.
J. Lighting Fixtures:
1. Lighting fixtures shall be of the fluorescent type as indicated.
2. The cost of furnishing and installing lamps for each of the fixtures shall be included in this price.
a. Fluorescent lamps shall be of the wattage and type indicated on the drawings with a color temperature of 3000K and a minimum CRI of 81, unless otherwise specified.
3. All fixtures shall be U.L. approved.
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02218Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NOT FOR CONSTRUCTION
AHA Consulting Engineers24 Hartwell Avenue, 3rd FloorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
N.T.S.
4/8
/2019
2:5
0:3
3 P
M
E0.03179-18-00
04/08/19
ELECTRICALSPECIFICATIONS
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
Issuance Schedule
Number Date Description
SSSS
SS
SMC
SMC
S
DS
DS
S
DS
C2
SMC
SS
S
SS
S
MS1
MS1 MS1
MS1
MS1
MS1MS1
MS1
MS1 MS1
S S
SMC
SMC
S S
S S
MS1
S
bD.05
bC.3
bC
bB.3
bB.1
bB
bA.8
SSSS
SMC
SMC
S
S
SMC
SS
S
SS
S
MS1
MS1 MS1
MS1
MS1 MS1
S S
SMC
S S
S S
MS1
SMC
S
SMC
S
SM
C
S S
S
SM
C
SMC
SHEET NOTES
KEYED NOTES
b1 b1.4 b2 b3 b3.2 b3.5 b4
bF
bE.3
bE
bD.9
bA.8
bB
bB.1
bB.3
bC
bC.3
bD
bA
a1
FJ4FJ4FJ4FJ4
FM
FG10
FG10
FG10
FG10
FG10
FG10
XM
XM
FG4
MS1 MS1 MS1MS1
MSMS
Z7
FM FJ4
MS
Z1,Z13,Z14
MS
X1
X1
X1
X1
Z3
Z20,Z21.
FJ4 FJ4 FJ4 FJ4
NLFD
FDFDFD FD FD
5/4
4
9 9 9 9 9 9 9
4
3
9
FL
Z1
FL
FL
Z1
FL
NL
FL
FL
FL
4
1
1
FG4 FG4 FG4 FG4
40404040P2121-40
cb cb cb ab
cba
FG4 FG4 FG4
38 38
38
P2121-38
cba
ab cb cb
FL
Z1
FL
Z1
FL
NL
FL
Z1
4
1
1
1
FL
NL4
37 ab
FG4
FD
NL
FD
Z1
FD
NL
FD-1
Z1
FD-1
Z1
FD-1
NL
FD-1
Z1
FD-1
Z1
FD
Z1
FD
Z1
FDZ1
4
1
1
1
4
1
1
4
1
1
FD
Z1
FD-1
NL
FD-1
Z1
FD-1
Z1
FD-1
Z1
FD-1
NL
FL
Z1
FL
Z2
FL
4
1
1
4
1
1
1
1
FD
Z11
FL
NL4
FL
Z15
FL
Z15
FL
NL
FL
Z15
FL
Z15
FL
NL111 1 4 4
FJ4
N.I
.C.
N.I
.C.
FB8
Z11 Z12 Z1313 4X1
4
a b
FG
FG
11
11
a,b
Z11 Z12 Z13
FB8
13 4
4
X1
X1
Z11 Z12 Z13
FB8
13 4
Z11,Z12,Z13
FB8
13 4Z11 Z13Z12
4
X1
L4121-13 L4121-13 E4131-4(VIA LCP12) (VIA LCP12) (VIA LCP12)
XM
XM
XM
XM
XM
XM
XM XM
XM
XM
XM
X
XM
a b
a b
a,b a,b
FG FG FG FG FG FG
a,b a,b a,b a,b a,b a,b11 11 11 11 11 11
XM XM XM
XM
XM XM
XM
XM XM
XM XM XM
L4121-11
Z8 Z9 Z107 4
FB8
XM
Z8 Z9 Z107 4
FB8XM
Z8
Z8 Z9
Z9 Z10
Z107 4
FB8
FB8
XM
XM
4
X1 XM
XMX1
4
X1XM
Z8,Z9,Z10 XM
39
X
X
X
X
X X X
X X
X XX
X X
X
X
X
X1
XM
X
X1 X
X X
7 4
L4121-7 L4121-7 E4131-4
(VIA LCP12) (VIA LCP12) (VIA LCP12)
XM
4
X
XR
XR
XR
MSa,b
a,b
XMXMXMXM XM
XM
XMXMXMXM
XM
XM
XM(TYP. 3)
XM
(TY
P. 3)
X
X
XMXM XM XM XM XM XM
X
XM XM XM XM
X
XM
XR
b1 b1.4 b2 b3 b3.2 b3.5 b4
bF
bE.3
bE
bD.9
bA.8
bB
bB.1
bB.3
bC
bC.3
bD
bA
a1
FJ4FJ4FJ4FJ4
FM
XM
XM
FG4
MS1 MS1 MS1MS1
Z7
FM
MS
Z1,Z13,Z14
MS
X1
X1
Z20,Z21.
FJ4 FJ4 FJ4
NLFD
5/4
4
9 9 9 9 9 9 9
4
3
9
FL
Z1
FL
Z1
FL
NL4
1
1
FG4 FG4 FG4 FG4
40404040cbcb cb ab
cba
FG4 FG4 FG4
38 38
38
P2121-38
cba
ab cb cb
FL
FL
FL
FL
4
1
1
1
FL
NL4
37 ab
FG4
FD
NL
FD
Z1
FD
NL
FD-1
Z1
FD-1
Z1
FD-1
NL
FD-1
Z1
FD-1
Z1
FD
Z1
FD
Z1
FDZ1
4
1
1
1
4
1
1
4
1
1
FD
Z1
FD-1
NL
FD-1
Z1
FD-1
Z1
FD-1
Z1
FD-1
NL
FL
Z1
FL
Z2
4
1
1
4
1
1
1
1
FD
Z11
FL
NL4
FL
Z15
FL
Z15
FL
NL
FL
Z15
FLZ15
FL
NL111 1 4 4
N.I
.C.
N.I
.C.
FB8
Z11 Z12 Z1313 4X1
4
a b
FG
FG
11
11
a,b
Z11 Z12 Z13
FB8
13 4
4
X1
Z11 Z12 Z13
FB8
13 4
FB8
13 4Z11 Z13Z12
4
X1
L4121-13 L4121-13 E4131-4(VIA LCP12) (VIA LCP12) (VIA LCP12)
XM
XM
XM
XM
XM
XM
XM XM
XM
XM
XM
XM
XL
a b
a b
a,b a,b
FG FG FG FG FG FG
a,b a,b a,b a,b a,b a,b
L4121-11
Z8 Z9 Z107 4
FB8
XM
Z8 Z9 Z107 4
FB8XM
Z8
Z8 Z9
Z9 Z10
Z10
7
7
4
4
FB8
FB8XM
4
4
X1
XM
X1
4
X1XM
Z8,Z9,Z10 XM
X1XM
(VIA LCP12) (VIA LCP12)
(VIA LCP12)
Z8 Z9 Z107 4
FB8
Z8 Z9 Z107 4
FB8
4
X1
4
X1
XM
4
FD
FD
XL
XL
Z14
7 Z14
Z14
R
E4131-4
L4121-7
(VIA
LC
P12)
4/7
FD XL
7 Z14
Z14
L4121-7
L4121-7
E4131-4
FJ4
FJ4
VS
11
11
Z11,Z
12,Z
13
FJ4
VS
9
FL
FL
FL
NL
Z15
Z15
4
1
1
XL
XL
XL
4X1
4
X1
4X1
XMXMXMXM XM
XMXMXMXM
XM
XM
XM(TYP. 3)
XM
(TY
P. 3)
P2121-40
XMXM
XMXM XM
XM
1 1TYP. 4 TYP. 2
XM VSXM XM XM XM XM XM
XM XM XM XM
MSa,b
XM
VS
Z15
Z15
L4121-1(VIA LCP12)
POD12079
CONFERENCE ROOM12082
CONFERENCE ROOM12083
CONFERENCE ROOM12029 CONFERENCE ROOM
12113CONFERENCE ROOM
12031
BREAKOUT ROOM12032
COPY/MAIL ROOM12012
POD12010
POD12011
POD12009
POD12008
POD12007
POD12006
XM XM XM
XM
XM XM
XM
XM XM
XM XM XM
OPEN OFFICE12081
OPEN OFFICE12084
OPEN OFFICE12081
1.
2.
3.
4.
E.C. SHALL CONFIRM EXACT DEMOLITION SCOPE AREA WITH THE ARCHITECTURAL DEMOLITION PLANS.
UNLESS OTHERWISE NOTED, EXISTING DEVICES/EQUIPMENT/FIXTURES SHALL REMAIN (XM).
E.C. SHALL CONFIRM EXACT LOCATIONS OF ALL FIXTURES WITH THE ARCHITECTURAL RCP'S.
ADD ALTERNATE #1: ELECTRICAL CONTRACTOR SHALL PROVIDE SEPARATE BREAK OUT PRICE TO RE-LAMP ALL EXISTING, RELOCATED, AND NEW COMPACT AND LINEAR FLUORESCENT, AND MR16 HALOGEN FIXTURES WITH THEIR EQUIVALENT LED RETROFIT LAMP. E.C. SHALL FIELD VERIFY EXACT QUANTITIES PRIOR TO BIDDING.
KEYED NOTE.1
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02218Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NORTH
NOT FOR CONSTRUCTION
AHA Consulting Engineers24 Hartwell Avenue, 3rd FloorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
As indicated
4/8
/2019
2:5
0:3
4 P
M
E1.12179-18-00
04/08/19
ELECTRICAL 12TH FLOORLIGHTING PLANS
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
1/8" = 1'-0"1
LEVEL 12 ELECTRICAL DEMO LIGHTINGPLAN
1/8" = 1'-0"2
LEVEL 12 ELECTRICAL NEW WORKLIGHTING PLAN
Issuance Schedule
Number Date Description
S
JPS
S
S
J
J
J JJ JJ
S
HP
5
JPS
S
JJJ
J
J
S
CIF
1
FPT
3
FPT
3
FCU
1
FCU
6
FCU
3
FCU
6
FCU
4
FCU
4
FCU
6
FCU
4
FCU
4
FPT
3
FPT
2
FCU
6
J
J J
JJ
FCU
4
J
J
J
J J
J
J
J
J J
J J
J J
JJ
J
J
J
J
J
CR
S
S
FCU
3
FCU
4
FPT
1
FCU
3
FPT
1
FPT
1
FCU
6
FPT
2
CR
JPS
S
S
J
J
J JJ JJ
S
HP
5
JPS
CIF
1
FPT
3
FPT
3
FCU
6
FCU
3
FCU
6
FCU
4
FCU
4
FCU
6
FCU
4
FCU
4
FPT
3
FPT
2
FCU
6
FCU
4
J
J J
J
J
J
CR
S
S
SS
J
J J
J
J
J
JJ
FCU
3
FCU
4
FPT
1
FCU
3
FPT
1
FPT
1
FCU
6
FPT
2
JJJ
CR
J
CR
J
JJ
FCU
1
CR
J
J
ELECTRICAL
1205
SHEET NOTES
KEYED NOTES
b1 b1.4 b2 b3 b3.2 b3.5 b4
bF
bE.3
bE
bD.9
bA.8
bB
bB.1
bB.3
bC
bC.3
bD
bA
a1
N.I
.C.
P2122
C
C
C
C
A/VA/V
PS
WS
WSWSWSWS
G
WS
TV
TV
27
24
22
24
8
8
28
32
WSWSWS
WS
WS
P2122- 33
L4121- 6
X X
C
C
C
CX
X
XM
XM
XM
X
X
XM
X
X
XM
XM
X
XM XM
X
XM
X
XM
X
XR
XR
XR
XR
XMXR
XR
N.I
.C.
XM
PT/D
X X
T/D
P X X
XM
XM
XM
T/D T/D
P P
XM
T/D T/D
P P
XM
P PT/D T/D
A/V
A/V
TV
TVWS
WS
T/DP
XM
XM
XM
XM
XM XM XM
XMXM
XX
XM
XX
XM
XM
XM
XMXR
T/D
PX X
T/D T/DP P
T/D
T/D
T/D
T/D
T/D
T/D
T/D
P
P
P
P
P
P
P
XM XM
XM XM
XM
XM
XM
XM
WS
XM
XM
XMXM
XM
XM
XM
XM
XM
XM
T/D
P
XM
X
XM
X
X
X
XM
XM XM
X X X
XM XM
X
X X
XM
X
XM
XM
XM
XM
L4121-26
XM
XM
X
XM XM XM XM
XMXM
XMXM
XM
XM
XM
XM XM
XMXMXM
XM
XM
XM
XM
XM
XM
XMXM
XM
XM
XR
XM
XXM
X
X
X
XM
XRS
XMRS
XM
XMXMXMXM
XRRS
XR
XM
C
C
X
X
WXM
X
WX
XM XM
XM
XR
L4121-18
XM
XM
XM
XM
XM
XM
XR
XM
b1 b1.4 b2 b3 b3.2 b3.5 b4
bF
bE.3
bE
bD.9
bA.8
bB
bB.1
bB.3
bC
bC.3
bD
bA
a1
N.I
.C.
P2122
C
C
A/VA/V
PS
WS
WSWSWSWS
G
WS
TV
TV
17
27
24
22
24
8
8
28
32
P2122- 33
L4121- 6
XM
XM XM XM
XL
XM
N.I
.C.
XM
XM
XM
XM
XM
T/D T/D
P
P
XM
A/V
A/V
WS
WS
XMXM
XM
T/DP
XM XM
XMXM
XM
XM
XM
WS
XM
XM
XMXM
XM
XM
XM
XM
XM
XM
XM XM
XM
XM
XM
XM
XM
XM
XM
XLXL
P2122-93,95,97,99
P2122-17,19,21,23
T/D
P
P2122-117,119,121,123
T/D
P
T/D
P
T/D
P
P2122-9,11,13,15
P2122-101,103,105,107
P2122-86,88,90,92
T/DP
T/DP
P2122-110,112,114,116
P2122-94,96,98,100
T/DP
T/DP
P2122-59,61,63,65 P2122-51,53,55,57
XM
XM
XM
XM
XM
XMXM
XL
XM
P2122-42
P2122-75
P2122-4
1
XM
XM
P2122-84
T/DP
P2122-118,120,122,124
T/DP
P2122-102,104,106,108
T/DP
P2122-85,87,89,91
XL
XM
XM
XM
XM XM XM
XMXM
XM
XM
XM
XM
XM
RSXL
XM XM XM XM
XM
XM
XMXM
XM
XM
XM
XM XM
XM
XMXMXM
XM
XM
XM
XM
XM
XMXM
XM
XM
XMRS
XMXMXMXM
27
28
T/D P
P2122-109,111,113,115
P2122-1,3,5,7
XMXM P2121-3
C CC C
P2121-7
7 7
WXM
T/D
P
XM
P2122-67,69,71,73
P
XM
P2122-25,27,29,31
T/DP
XM
P2122-34,36,38,40
T/D
75
75
P2122-77
77
77
42
82 82
P2122-82
XL
XL
C
C
CC
XM
XM
XM
XM
XM
XM
L4121- 18
XL
XM
49
TV TV
49
CONFERENCE ROOM12113
CONFERENCE ROOM12029
CONFERENCE ROOM12031
BREAKOUT ROOM12032
POD12006
POD12007
POD12008
POD12009
POD12010
POD12011
COPY/MAIL ROOM12012
CONFERENCE ROOM12082
CONFERENCE ROOM12083
OPEN OFFICE12081
POD12079
OPEN OFFICE12084
XL
XL
XL
XM
XM
b4
bC.3
bD
EXISTINGBUSDUCT CN1
T7A
P2121
XM
XM
XM
ATC
LCP12
L4121
ATCXM
XM
XM
XM
XM
XM
XM
XM
1.
2.
3.
4.
5.
6.
7.
E.C. SHALL CONFIRM EXACT DEMOLITION SCOPE AREA WITH ARCHITECTURAL DEMOLITION PLANS.
UNLESS OTHERWISE NOTED, EXISTING DEVICES/EQUIPMENT/FIXTURES SHALL REMAIN (XM).
CONFIRM DEMOLITION SCOPE OF WORK WITH HVAC/PLUMBING DEMOLITION DRAWINGS.
E.C. SHALL CONFIRM EXACT LOCATIONS OF ALL DEVICES WITH ARCHITECTURAL POWER AND TELE/DATA LOCATION PLANS AND ELEVATIONS.
E.C. SHALL CONFIRM ALL REQUIRED T/D BOX AND RACEWAY REQUIREMENTS WITH T/D SYSTEM INSTALLER AND PROVIDE AS REQUIRED.
E.C. SHALL CONFIRM ALL A/V BOX AND RACEWAY REQUIREMENTS WITH A/V SYSTEM INSTALLER AND PROVIDE AS REQUIRED. COORDINATE ALL AUDIO/VIDEO PURPOSED POWER CIRCUITS SHALL BE FED FROM THE SAME PANEL PHASE LEG (A/B/C). CONFIRM WITH A/V SYSTEM INSTALLER.
E.C. SHALL CIRCUIT ALL NEW AND RELOCATED VV BOXES IN THIS AREA TO THE EXISTING VV BOX CIRCUIT SERVING THE SCOPE AREA. COORDINATE EXACT QUANTITIES AND LOCATIONS WITH THE HVAC DRAWINGS.
KEYED NOTE.1
Scale: Date Issued:
Project Number:
Isgenuity LLC500 Harrison Avenue, Suite 5FBoston, MA 02218Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
NORTH
NOT FOR CONSTRUCTION
AHA Consulting Engineers24 Hartwell Avenue, 3rd FloorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
As indicated
4/8
/2019
2:5
0:3
6 P
M
E2.12179-18-00
04/08/19
ELECTRICAL 12TH FLOORPOWER PLANS
VERTEXPHARMACEUTICALS
12TH FLOOR CALL CENTER
ISSUED FOR BID
1/8" = 1'-0"1
LEVEL 12 ELECTRICAL DEMO POWERPLAN
1/8" = 1'-0"2
LEVEL 12 ELECTRICAL NEW WORKPOWER PLAN
1/8" = 1'-0"3
LEVEL 12 ELECTRICAL NEW WORKPOWER PART PLAN
Issuance Schedule
Number Date Description
ALARMFIRE
PULL DOWN
TYPICAL DEVICE MOUNTING DIAGRAM
S
S
F
1. ALL WIRING FOR THE FIRE ALARM SYSTEM SHALL BE AS FOLLOWS:
A. ABOVE SUSPENDED CEILINGS: METAL CLAD CABLE, TWISTED PAIR,IN CONFORMANCE WITH SYSTEM MANUFACTURER'S REQUIREMENTS AND ASPER APPROVED SHOP DRAWINGS.
B. FROM SUSPENDED CEILING TO SURFACE MOUNTED DEVICE: TWISTED PAIR,IN SURFACE MOUNTED RACEWAYS, IN CONFORMANCE WITH SYSTEM .MANUFACTURER'S REQUIREMENTS AND AS PER APPROVED SHOP DRAWINGS.
C. ON CMU/CONCRETE WALLS AND CEILINGS: TWISTED PAIR, IN CONDUITS,IN CONFORMANCE WITH SYSTEM MANUFACTURER'S REQUIREMENTS AND ASPER APPROVED SHOP DRAWINGS.
D. ON PLASTERED WALLS/CEILINGS: METAL CLAD CABLE, TWISTED PAIR,IN CONFORMANCE WITH SYSTEM MANUFACTURER'S REQUIREMENTS ANDAS PER APPROVED SHOP DRAWINGS.
2. ALL WALL MOUNT DEVICES (HORN/STROBES, MANUAL PULL STATIONS ETC.)SHALL BE INSTALLED AS FOLLOWS:
A. FOR ALL PLASTERED WALLS:- MOUNT DEVICES ON A RECESSED BACK BOX IN WALL.- WIRING TO THE DEVICE SHALL BE CONCEALED IN WALL FROM THE
SUSPENDED CEILING ABOVE.
B. FOR ALL CMU/COMCRETE WALL:- MOUNT DEVICES ON A MANUFACTURER'S PROVIDED STEEL BACK BOX.
3. MOUNTING HEIGHT AND CANDELA RATING OF FIRE ALARM DEVICES SHALL BEIN COMPLETE COMPLIANCE WITH THE MASSACHUSETTS ARCHITECTURALACCESS BOARD REGULATIONS (MAAB 521 CMR).
4. PRIOR TO FURNISHING AND INSTALLING FIRE ALARM SYSTEM EQUIPMENT,DEVICES, AND WIRING, THE ELECTRICAL CONTRACTOR SHALL CONFER WITHLOCAL FIRE AUTHORITY FOR ALL REQUIREMENTS.
5. ALL EXPOSED WIRING SHALL BE IN MINIMUM 1/2" CONDUIT.
6. CONTRACTOR IS RESPONSIBLE FOR ENSURING ALL VISUAL NOTIFICATIONDEVICES ARE SYNCHRONIZED.
7. UNDER NO CIRCUMSTANCES SHALL THE CONTRACTOR ADD ANY NEW DETECTIONOR NOTIFICATION DEVICES TO EXISTING BY MEANS OF T-TAPPING.
8. PROVIDE A NEW FIRE ALARM DEVICE LAYOUT IN ACCORDANCE WITH THESEPLANS AND NFPA 72.
FIRE ALARM GENERAL NOTES
75
75
NOT IN FIRE ALARM CONTRACT
LIMIT OF FIRE ALARM CONTRACT
NIFAC
LFAC
RELOCATE EXISTING DEVICE
REMOVE EXISTING DEVICE
LIGHT LINE INDICATES EXISTING WORK TO REMAIN
RE
XR
ETR
LIGHT DASHED LINE INDICATES EXISTING FIRE ALARM STROBE ANDSPEAKER, NUMERAL INDICATES CANDELA RATING
LIGHT DASHED LINE INDICATES EXISTING FIRE ALARM CEILING STROBE ANDSPEAKER, NUMERAL INDICATES CANDELA RATING
LIGHT DASHED LINE INDICATES EXISTING FIRE ALARM MANUAL PULL STATION
NEW LOCATION OF EXISTING DEVICEXL
FIRE ALARM LEGEND
S
S
F
75
75
FIRE ALARM STROBE AND SPEAKER, NUMERAL INDICATES CANDELA RATING
FIRE ALARM CEILING STROBE AND SPEAKER, NUMERAL INDICATES CANDELA RATING
FIRE ALARM MANUAL PULL STATION
F
75
FIRE ALARM STROBE ONLY DEVICE, NUMERAL INDICATES CANDELA RATING
NOT TO SCALE
42" -
48"
80" -
96"
FIRE ALARM SIGNAL
WALL STUDS
ALIGN DEVICES ON COMMONCENTERLINES USE STUD SPANS.DO NOT ALIGN ON STUDS.
MANUAL PULL STATION
REFER TO SYMBOLLISTS FOR MOUNTINGHEIGHTS OF OTHERDEVICES
TOP OFLEVER
BOTTOM OFSTROBE
FINISHED
FLOOR
I. GENERAL
A. THE WORK CONSISTS OF FURNISHING ALL LABOR AND MATERIALS NECESSARY TO INSTALL, COMPLETE AND READY FOR
CONTINUOUS OPERATION, THE FIRE ALARM SYSTEMS, APPARATUS AND EQUIPMENT AS SHOWN IN THE PROPOSED
CONSTRUCTION DOCUMENTS HEREIN.
B. SHOP DRAWINGS OF ALL SPECIFIED FIXTURES, EQUIPMENT AND APPARATUS SHALL BE SUBMITTED TO THE OWNER FOR
APPROVAL.
C. CODES: ALL EQUIPMENT AND MATERIALS FURNISHED UNDER THE ELECTRICAL SUB-CONTRACTS AND LABOR PERFORMED
HEREIN SHALL BE IN COMPLETE ACCORDANCE WITH THE MASS STATE BUILDING AND ELECTRICAL CODES, LOCAL ORDINANCES
AND REGULATIONS OF THE CITY OF BOSTON, NATIONAL FIRE PROTECTION ASSOCIATION AND INSURANCE REGULATIONS AND
REQUIREMENTS GOVERNING SUCH WORK.
D. PERMITS: ANY AND ALL PERMITS REQUIRED FOR INSTALLATION OF ANY MATERIAL SHALL BE OBTAINED AS PART OF THE
WORK OF THE SPECIFICATION INCLUDING ALL FEES OR EXPENSES INCURRED.
E. INSTRUCTIONS: DURING THE ASSEMBLY AND INSTALLATION OF ALL ELECTRICAL SYSTEMS, THE OWNER'S OPERATING
PERSONNEL SHALL BE INSTRUCTED REGARDING ITS OPERATION AND MAINTENANCE. AN INSTRUCTION PERIOD SHALL BE
PROVIDED AFTER COMPLETION OF PROJECT. OPERATION AND MAINTENANCE MANUALS SHALL BE REQUIRED.
F. GUARANTEE: ALL MATERIALS AND EQUIPMENT, FURNISHED AND INSTALLED, SHALL BE GUARANTEED IN WRITING FOR ONE (1)
YEAR FROM THE DATE OF ACCEPTANCE OF THE BUILDING BY THE OWNER.
G. RECORD DRAWINGS: THE FIRE ALARM SUBCONTRACTOR SHALL MAINTAIN AT THE JOB, AT ALL TIMES, A COMPLETE AND
SEPARATE SET OF BLACKLINE PRINTS OF THE ELECTRICAL DRAWINGS OF HIS TRADE ON WHICH HE SHALL MARK CLEARLY,
NEATLY, ACCURATELY AND PROMPTLY AS THE WORK PROGRESSES. MYLAR REPRODUCIBLE "AS-BUILTS" SHALL BE FURNISHED
BY THE ELECTRICAL SUBCONTRACTOR AT THE JOB COMPLETION.
H. INSPECTION: ALL WORK SHALL BE SUBJECT TO THE INSPECTION OF THE OWNER AND SUCH OTHER INSPECTORS HAVING
JURISDICTION. A PROPERLY EXECUTED CERTIFICATE OF INSPECTION SHALL BE PROVIDED.
I. TESTS: THE FIRE ALARM SUBCONTRACTOR SHALL PERFORM ALL TESTS AT THE COMPLETION OF THE WORK AND THE
RESULTS FURNISHED TO THE OWNER IN WRITING. TESTS SHALL INCLUDE BUT NOT BE LIMITED TO: ALL SYSTEMS TEST FREE OF
SHORTS OR GROUNDS, PROPER NEUTRAL CONNECTIONS, GROUND SYSTEM RESISTANCE.
J. UPON COMPLETION OF ALL WORK, THE FIRE ALARM SUBCONTRACTOR SHALL FURNISH, IN DUPLICATE, CERTIFICATES OF
INSPECTIONS FROM ALL INSPECTORS AND AUTHORITIES HAVING JURISDICTION, NOTARIZED LETTERS FROM THE
MANUFACTURERS STATING THAT AUTHORIZED FACTORY ENGINEERS HAVE INSPECTED AND TESTED THE INSTALLATION OF THEIR
RESPECTIVE SYSTEMS AND FOUND SAME TO BE IN PERFECT OPERATING CONDITION.
II. SCOPE
A. THE WORK OF THIS SECTION CONSISTS OF ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED TO PROVIDE ALL ELECTRICAL
WORK, NOT SPECIFICALLY DESCRIBED IN OTHER TRADES COMPLETE, IN PLACE, AS SHOWN ON THE DRAWINGS, SPECIFIED
HEREIN AND AS NECESSARY FOR A PROPER INSTALLATION.
B. THE EXTENT OF THE WORK SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING:
1. PROVIDE AN EXTENSION TO EXISTING EDWARDS EST-3 ADDRESSABLE FIRE DETECTION, ALARM AND CONTROL SYSTEM WITH
SPEAKER/STROBE SIGNALS FOR THE RENOVATED AREAS IN COMPLIANCE WITH APPLICABLE SPECIFICATIONS AND DRAWINGS.
THE SYSTEM SHALL INTERFACE TO OTHER BUILDING SYSTEMS TO CONDUCT MONITORING AND CONTROL FUNCTIONS AS
DESCRIBED HEREIN.
2. ALL NEW DEVICES SHALL BE OF THE SAME MANUFACTURER AS EXISTING SYSTEM AND SHALL BE COMPATIBLE WITH EXISTING
EQUIPMENT.
III. SUBMITTALS
A. SUBMIT FOR APPROVAL, WITHIN THIRTY (30) DAYS AFTER SIGNING THE CONTRACT AND PRIOR TO THE SUBMISSION OF ANY
SHOP DRAWINGS, AN ITEMIZED LIST OF MANUFACTURERS OF MATERIALS AND EQUIPMENT AND OF SUBCONTRACTORS
PROPOSED TO BE USED UNDER THIS SECTION.
B. AFTER APPROVAL OF THE LIST, PROVIDE SUBMITTALS IN ACCORDANCE WITH THE "SUBMITTALS" SECTION OF THIS
SPECIFICATION. ALL SHOP DRAWINGS FOR EQUIPMENT SUBMITTED FOR REVIEW SHALL INCLUDE COMPLETE SPECIFICATIONS,
INCLUDING TYPE OF MATERIALS, OPERATING PRESSURES AND TEMPERATURES, CAPACITIES, PERFORMANCE AND POWER
REQUIREMENTS TO DETERMINE COMPLIANCE WITH CONTRACT DOCUMENTS. WIRING DIAGRAM SUBMITTED SHALL BE COMPLETE
FOR ALL EQUIPMENT AND SHALL APPLY ONLY TO THIS SPECIFIC PROJECT.
C. THE SHOP DRAWINGS AND MANUFACTURERS DATA SHALL BE SUBMITTED IN A TIMELY MANNER SUFFICIENTLY IN ADVANCE TO
GIVE AMPLE TIME FOR CHECKING, CORRECTING, RESUBMITTING AND RECHECKING IF NECESSARY. NO CLAIM FOR DELAY WILL BE
GRANTED FOR FAILURE TO COMPLY WITH THIS REQUIREMENT.
D. SUBMIT SHOP DRAWINGS ON THE FOLLOWING:
1. CABLE AND WIRE.
2. CONDUIT.
3. DEVICES.
4. FIRE ALARM SYSTEM.
5. LOW VOLTAGE AND BATTERY CALCULATIONS.
- COMPLETE POINT-TO-POINT RISER DIAGRAM AND DEVICE LOCATION PLANS SHOWING ALL EQUIPMENT AND SIZE, TYPE,
LOCATION, AND NUMBER OF ALL CONDUCTORS AND DEVICES.
- LARGE SCALE DRAWINGS OF THE FACP AND REMOTE PANELS SHOWING MODULE PLACEMENT AND SPARE CAPACITY
ALLOWANCES.
- ADDRESSES FOR ALL FIELD DEVICES SHOWN ON FLOOR PLANS AND KEY LISTS. KEY LISTS SHALL INCLUDE DEVICE TYPE,
ADDRESS, LOCATION AND CORRESPONDING LCD MESSAGE TEXT. THE INSTALLING CONTRACTOR SHALL COORDINATE MESSAGE
ASSIGNMENTS WITH THE OWNER AND LOCAL AUTHORITIES PRIOR TO SYSTEM PROGRAMMING.
IV. SEISMIC RESTRAINTS
A. INSTALLATION OF NEW FIRE ALARM EQUIPMENT, ACCESSORIES AND COMPONENTS SHALL BE IN ACCORDANCE WITH THE
SEISMIC REQUIREMENTS IDENTIFIED IN THE MASSACHUSETTS STATE BUILDING CODE, NINTH (9TH) EDITION.
V. MATERIALS
A. WIRE AND CABLE:
1. ALL WIRE AND CABLE SHALL HAVE COPPER CONDUCTORS. COPPER WIRES SHALL BE SOFT DRAWN, ANNEALED, 98 PERCENT
CONDUCTIVITY, AND INSULATED FOR 600 VOLTS. WIRE SIZES #14 THROUGH #6 AWG SHALL BE TYPE THHN-THWN.
2. FIRE-PROTECTIVE SIGNALING WIRING SHALL BE IN ACCORDANCE WITH THE ELECTRICAL CODE, ARTICLE 760, FIRE
PREVENTION SYSTEMS FOR BUILDING FIRE ALARM SYSTEMS, AND AS INDICATED ON THE DRAWINGS. ALL WIRES FOR THE LOCAL
FIRE ALARM SYSTEM SHALL BE COLOR-CODED AND SIZED AS RECOMMENDED BY THE MANUFACTURER OF THE FIRE ALARM
SYSTEM, AND SHALL BE INSTALLED IN CONDUIT. THE COMBINED CROSS-SECTIONAL AREA OF ALL CONDUCTORS OR CABLES
SHALL NOT EXCEED THE PERCENTAGE OF FILL SPECIFIED IN TABLE 1, CHAPTER 9 OF THE ELECTRICAL CODE.
3. PROVIDE COMPLETE WIRING AND CONDUIT BETWEEN ALL EQUIPMENT. ALL DEVICES SHALL BE MOUNTED UPON AND
TERMINATIONS MADE IN TERMINAL CABINETS. WIRING SPLICES AND TRANSPOSING OR CHANGING OF COLORS WILL NOT BE
PERMITTED.
4. ALL WIRING TYPES AND SIZES SHALL BE AS FOLLOWS OR AS OTHERWISE REQUIRED BY THE EQUIPMENT MANUFACTURER:
- ADDRESSABLE LOOP WIRING SHALL UTILIZE MINIMUM #16 AWG WIRING.
- NOTIFICATION APPLIANCE CIRCUITS SHALL UTILIZE #14 THHN.
B. OUTLET, JUNCTION AND PULL BOXES:
1. FURNISH AND INSTALL OUTLET, JUNCTION AND PULL BOXES AS SPECIFIED HEREIN AND WHERE SHOWN ON THE CONTRACT
DRAWINGS AND AT ALL OTHER LOCATIONS WHERE THEY ARE REQUIRED TO FACILITATE THE PULLING, SUPPORTING OR
CONNECTION OF WIRES AND CABLES.
C. MOUNTING HEIGHTS
1. ALL ELECTRICAL EQUIPMENT SHALL BE MOUNTED AT THE FOLLOWING HEIGHTS UNLESS NOTED OR DETAILED OTHERWISE ON
THE FIRE ALARM DRAWINGS OR ARCHITECTURAL DRAWINGS. ALL MOUNTING HEIGHTS SHALL COMPLY WITH THE FEDERAL ADA
(AMERICANS WITH DISABILITIES ACT) AND THE STATE OF MASSACHUSETTS PUBLICATION 521 CMR: ARCHITECTURAL BARRIERS
BOARD FOR (BUILDINGS, FACILITIES, ETC. FOR THE VISUALLY AND PHYSICALLY HANDICAPPED).
- FIRE ALARM PULL STATIONS: 4'-0" ABOVE FINISHED FLOOR TO THE TOP OF THE ACTIVATING LEVER.
- FIRE ALARM SIGNALS: (SPEAKER/STROBES) 6'-8" ABOVE FINISHED FLOOR TO BOTTOM OF THE STROBE.
VI. FIRE ALARM EQUIPMENT
A. THE SYSTEM IS SUPPORTED BY STANDBY BATTERIES. PROVIDE NEW BATTERY CALCULATIONS AND REPLACE BATTERIES,
BASED ON THE FOLLOWING CRITERIA:
1. IN THE EVENT OF A LOSS OF PRIMARY POWER, BATTERIES SHALL SUPPORT 24 HOURS OF FULL SUPERVISORY OPERATION
FOLLOWED BY 15 MINUTES OF ALARM. PROVIDE INCREASED CAPACITY OF 20% FOR SAFETY AND BATTERY DEGRADATION.
B. ALL EQUIPMENT SHALL BE NEW AND UNUSED. ALL COMPONENTS AND SYSTEMS SHALL BE DESIGNED FOR UNINTERRUPTED
DUTY. ALL EQUIPMENT, MATERIALS AND ACCESSORIES COVERED BY THESE REQUIREMENTS SHALL BE PROVIDED BY A SINGLE
MANUFACTURER OR, IF PROVIDED BY DIFFERENT MANUFACTURERS, RECOGNIZED AS COMPATIBLE BY BOTH MANUFACTURERS.
C. CIRCUITING GUIDELINES: EACH MANUAL OR AUTOMATIC DETECTION DEVICE AND INDICATING CIRCUIT SHALL BE INDIVIDUALLY
ADDRESSABLE. CIRCUIT WIRING SHALL MATCH EXISTING WIRE CONVENTION.
1. NOTIFICATION APPLIANCE CIRCUITS SHALL ALLOW SILENCING OF THE AUDIBLE SIGNALS WHILE MAINTAINING AN ACTIVE
VISUAL INDICATION.
D. SYSTEM COMPONENTS:
1. VISUAL SIGNALS: FURNISH AND INSTALL SELF-SYNCHRONIZING XENON STROBES RATED BY UL 1971 TEST CRITERIA AND IN
ACCORDANCE WITH THE AMERICANS WITH DISABILITIES ACT AND NFPA 72. VISUAL SIGNALS SHALL HAVE A MINIMUM EFFECTIVE
INTENSITY RATING OF 15 CANDELA.
2. AUDIBLE SIGNALS: PROVIDE AUDIBLE SIGNALS (SPEAKERS) TO PRODUCE A MINIMUM REVERBERANT SOUND LEVEL OF 85BD,
OR 15 DB ABOVE AMBIENT AT 10 FEET, WHICHEVER IS GREATER. ALL AUDIO AND VISUAL DEVICES SHALL BE SYNCHRONIZED.
ONLY THE 1-WATT AND 2-WATT SETTING SHALL BE USED FOR THE SPEAKER.
3. AUXILIARY STROBE POWER SUPPLIES: PROVIDE DISTRIBUTED INTELLIGENT POWER SUPPLIES WHERE REQUIRED TO
ACCOMMODATE THE POWER REQUIREMENTS OF NOTIFICATION APPLIANCE CIRCUITS. POWER SUPPLIES SHALL COMMUNICATE
WITH THE FACP VIA DATA COMMUNICATIONS, WHEREBY EACH POWER SUPPLY SHALL REPORT A LOSS OF AC POWER, BATTERY
FAIL OR GROUND FAULT, AND EACH NOTIFICATION APPLIANCE CIRCUIT SERVED SHALL BE INDIVIDUALLY MONITORED FOR WIRING
INTEGRITY.
VII. DEMOLITION
A. ALL DEMOLITION WORK, AS INDICATED ON THE DRAWINGS, SHALL BE PERFORMED BY THE FIRE ALARM CONTRACTOR.
DEMOLISHED ITEMS SHALL BE REMOVED FROM THE PREMISES.
B. ALL EXISTING DEVICES, WIRING, ETC. SHALL BE DEMOLISHED UNLESS OTHERWISE NOTED OR INDICATED ON THE DRAWINGS.
CARE SHALL BE TAKEN DURING DEMOLITION WORK TO MAINTAIN THE INTEGRITY OF THE EXISTING WIRING WHICH MAY BE
REUSED.
C. EXISTING CONDUCTORS AND CABLES RUN ABOVE CEILING, NOT RUN IN METAL RACEWAY AND NOT TEFLON COATED, SHALL
BE DISCONNECTED, REMOVED AND REPLACED SO AS TO BE SUITABLE FOR AIR HANDLING PLENUMS, PER LOCAL, STATE AND
NATIONAL CODES.
D. EXISTING FIRE ALARM RACEWAYS, WIRING, JUNCTION BOXES, OUTLET BOXES AND PULL BOXES MAY BE REUSED WHEREVER
POSSIBLE. THE FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE MECHANICAL INTEGRITY OF ANY
EXISTING RACEWAY SYSTEMS THAT ARE TO BE REUSED.
E. WHERE REQUIRED, THE EXISTING RACEWAY SYSTEM SHALL BE EXTENDED TO NEW DEVICE LOCATIONS AS INDICATED ON THE
DRAWINGS. IN GENERAL, ALL NEW RACEWAYS IN FINISHED AREAS SHALL BE RUN CONCEALED IN BUILDING CONSTRUCTION,
ABOVE HUNG CEILINGS, IN MASONRY OR STUD WALLS, ETC. WHERE REQUIRED, NEW RACEWAYS RUN IN THE EXISTING BUILDING
MAY BE RUN EXPOSED. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ARCHITECT REGARDING LOCATION AND
ROUTING OF ANY EXPOSED RACEWAYS PRIOR TO INSTALLING SAME.
F. CLEANING UP
1. UPON COMPLETION OF ALL INSTALLATION, AND TESTING, THOROUGHLY INSPECT ALL EXPOSED PORTIONS OF THE FIRE
ALARM INSTALLATION AND COMPLETELY REMOVE ALL EXPOSED LABELS, MARKINGS, AND FOREIGN MATERIAL.
2. THE INTERIOR OF ALL BOXES AND CABINETS SHALL BE LEFT CLEAN; EXPOSED SURFACES SHALL BE CLEANED AND PLATED
SURFACES POLISHED.
3. REPAIR DAMAGE TO FINISH SURFACES RESULTING FROM WORK UNDER THIS SECTION.
4. REMOVE MATERIAL AND EQUIPMENT FROM AREAS OF WORK AND STORAGE AREAS.
FIRE ALARM SPECIFICATION
planninarchitectureinteriors
g
Scale: Date Issued:
Project Number:
Isgenuity LLC321 Summer Street, Suite 401Boston, MA 02210Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
AHA Consulting Engineers24 Hartwell Avenue, 3rd floorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
12" = 1'-0"
4/8
/2019
2:4
9:4
0 P
M
FA0.00179.02.00
04/08/2019
FIRE ALARM LEGEND,NOTES, & DETAIL
VERTEX
PHARMACEUTICALS12TH FLOOR CALL CENTER
ISSUED FOR BIDNOT FOR CONSTRUCTION
Issuance Schedule
Number Date Description
S30
F15
S110
S15
S15
S30
S30
S30
F15
S15
S30
S30
S15
S30
F75
S75
S75
S
15
S75
S15
S15
S15
b1 b1.4 b2 b3 b3.2 b3.5 b4
bF
bE.3
bE
bD.9
bD
ETR
ETR
ETR
ETR
ETR
MATCHLINE
ETR
ETR
ETRETR
ETR
XR
NIF
AC
LF
AC
NIF
AC
LF
AC
NIF
AC
LF
AC
MATCHLINE
CONFERENCE ROOM12029
CONFERENCE ROOM12082
CONFERENCE ROOM12083
75
CHANGE CANDELA TO 75CD
ETRETR
POD12007
POD12008
POD12009
POD12010
POD12006
POD12011
COPY/MAIL ROOM12012
CONFERENCE ROOM12113
CONFERENCE ROOM12031
BREAKOUT ROOM12032
XL
planninarchitectureinteriors
g
Scale: Date Issued:
Project Number:
Isgenuity LLC321 Summer Street, Suite 401Boston, MA 02210Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
AHA Consulting Engineers24 Hartwell Avenue, 3rd floorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
1/4" = 1'-0"
4/8
/2019
2:4
9:4
1 P
M
FA1.12A179.02.00
04/08/2019
FIRE ALARM 12TH FLOORNORTH PLAN
VERTEX
PHARMACEUTICALS12TH FLOOR CALL CENTER
ISSUED FOR BIDNOT FOR CONSTRUCTION
Issuance Schedule
Number Date Description
FS110
S75
FS110
S110
S75
S75
S30
S75
F15
S75
b1 b1.4 b2
bA.8
bB
bB.1
bB.3
bC
bC.3
bA
ETR
MATCHLINE
ETR
ETR
ETR
??
ETR
NIF
AC
LF
AC
NIF
AC
LF
AC
XR
XL
MATCHLINE
ETR
CHANGE CANDELA TO 15CD
15
planninarchitectureinteriors
g
Scale: Date Issued:
Project Number:
Isgenuity LLC321 Summer Street, Suite 401Boston, MA 02210Tel 617 419 4660Fax 617 419 4661www.isgenuity.com
Architect
AHA Consulting Engineers24 Hartwell Avenue, 3rd floorLexington, MA 02421Tel 781 372 3000
MEP/FP Engineer
1/4" = 1'-0"
4/8
/2019
2:4
9:4
1 P
M
FA1.12B179.02.00
04/08/2019
FIRE ALARM 12TH FLOORSOUTH PLAN
VERTEX
PHARMACEUTICALS12TH FLOOR CALL CENTER
ISSUED FOR BIDNOT FOR CONSTRUCTION
Issuance Schedule
Number Date Description