     MBE ELECTRONIC C ONTROLS APPLICATION AND INSTALLATION 

    5.8 IDLE SHUTDOWN TIMER AND VSG SHUTDOWN

    The Idle Shutdown Timer will shutdown the engine if it remains idling for a specified period of 

    time. The options that can operate with Idle Shutdown Timer are Idle Shutdown Override, Vehicle

    Power Shutdown or Shutdown on Variable Speed Governor (VSG).

    5.8.1 OPERATION

    Certain conditions must be met for the entire time-out period for shutdown to occur. These

    conditions include:

    Coolant temperature above 14 F (–10 C)

    Engine operation at idle

    The parking brake interlock digital input switched to battery ground

    OEM supplied interlocks enabled

    Ignition ON

    Fueling is stopped after the specified idle time; the ignition circuit remains active after the engine

    shuts down. The AWL will flash 20 seconds before the shutdown occurs. The RSL will flash 10

    seconds before shutdown occurs. The AWL will blink until the ignition is turned off to indicate

    shutdown has occurred. The ignition switch must be cycled to OFF (wait 10 seconds) and back to

    ON before the engine will restart, if shutdown occurs.

    All information subject to change without notice.   (Rev. 7/03)   5-637SA822 0307   Copyright © 2003 DETROIT DIESEL CORPORATION

  • 8/15/2019 12_idle shutdown.pdf

    2/4

    FEATURES 

    A Park Brake Switch must be installed (see Figure 5-13). Idle Shutdown Timer operates with a

    digital input configured as a park brake and switched to battery ground. The time can range from

    1 to 1000 seconds (approximately 16 minutes).

    Figure 5-13 Park Brake Digital Input

    Idle Shutdown Override - Optional

    Idle Shutdown Override allows the operator to override the idle shutdown to keep the engine

    idling if this feature is enabled.

    If the accelerator pedal has been pressed or the park brake has been released, the conditions for the

    idle shutdown are no longer valid. The shutdown conditions must be met to reinitialize the counter.

    The timer can be reset by one of the following conditions:

    Engine Shutdown override button has been pressed

    Clutch pedal has been pressed

    Service brake has been pressed

    5-64   All information subject to change without notice.  (Rev. 7/03)7SA822 0307   Copyright © 2003 DETROIT DIESEL CORPORATION

  • 8/15/2019 12_idle shutdown.pdf

    3/4

     MBE ELECTRONIC C ONTROLS APPLICATION AND INSTALLATION 

    Vehicle Power Shutdown - Optional

    Vehicle Power Shutdown is used with Idle Timer Shutdown or Engine Protection Shutdown.

    After the idle timer times out or engine protection shuts the engine down, the Vehicle Power

    Shutdown relay shuts down the rest of the electrical power to the vehicle.

    A Vehicle Power Shutdown relay can be installed to shutdown all electrical loads when the

    engine is shutdown (see Figure 5-14). The engine will shutdown after the specified idle time and

    will reset the relay (ignition circuit).

    Figure 5-14 Vehicle Power Shutdown RelayAll electrical loads that should be turned OFF when the engine shuts down should be wired

    through this relay.

    Shutdown on VSG - Optional

    This option, when enabled, allows the engine to be shutdown when operating on VSG when the

    conditions are met for the Idle Timer Shutdown.

    Maximum Engine Load Shutdown — Optional

    This option, when enabled, allows the setting of a maximum load above which idle shutdown is

    disabled.

    All information subject to change without notice.   (Rev. 7/03)   5-657SA822 0307   Copyright © 2003 DETROIT DIESEL CORPORATION

  • 8/15/2019 12_idle shutdown.pdf

    4/4

    FEATURES 

    5.8.2 PROGRAMMING REQUIREMENTS AND FLEXIBILITY

    To program the Idle Shutdown timer, the digital input listed in Table 5-43 must be configured.

    Description Pin Type   Setting Default   Parameter ID

    Park Brake 21/16 Digital Input  0 = Disabled

    1 = Enabled  1 1 13 07

    Table 5-43 Idle Shutdown Timer Digital Input

    The Idle Shutdown timer options listed in Table 5-44 can be programmed by VEPS or minidiag2.

    Parameter Description   Choice / Range Default  Parameter

    ID

    IDLE SHUTDOWN

    ENABLED

    Enables or Disables the Idle

    Shutdown feature.

    0 = Disable

    1 = Enable  0 1 02 01

    IDLE SHUTDOWN TIME

    (MIN)

    The amount of engine idle time

    that is allowed before the Idle

    Shutdown feature stops fueling

    the engine.

    1 to 1000 seconds 60 sec 1 02 02

    ENABLED VSG

    SHUTDOWN

    Enables or disables the Idle Timer

    Shutdown feature when operating

    on the Variable Speed Governor.

    0 = Disable

    1 = Enable  0 1 02 03

    VSG SHUTDOWN TIME

    The amount of engine idle time

    that is allowed before the idle

    shutdown feature stops fueling

    the engine.

    1 to 1000 seconds 60 sec 1 02 04

    Time for AWL to flash  Time the AWL will flash before

    the shutdown occurs  3–120 sec 20 sec 1 02 06

    Time for RSL to flash  Time the RSL will flash before the

    shutdown occurs  3–120 sec 10 sec 1 02 07

    MIN COOLANT TEMP

    FOR SHUTDOWN

    Minimum coolant temperature

    before an idle shutdown will occur  -40 C to 200 C -10 C   1 02 08

    ENABLE IDLE/VSG

    SHUTDOWN OVERRIDE

    Enables/disables override of Idle

    or VSG Shutdown

    0 = Disable

    1 = Enable  1 1 02 09

    Table 5-44 Idle Shutdown Timer Programming Options