MBE ELECTRONIC C ONTROLS APPLICATION AND INSTALLATION
5.8 IDLE SHUTDOWN TIMER AND VSG SHUTDOWN
The Idle Shutdown Timer will shutdown the engine if it remains idling for a specified period of
time. The options that can operate with Idle Shutdown Timer are Idle Shutdown Override, Vehicle
Power Shutdown or Shutdown on Variable Speed Governor (VSG).
5.8.1 OPERATION
Certain conditions must be met for the entire time-out period for shutdown to occur. These
conditions include:
Coolant temperature above 14 F (–10 C)
Engine operation at idle
The parking brake interlock digital input switched to battery ground
OEM supplied interlocks enabled
Ignition ON
Fueling is stopped after the specified idle time; the ignition circuit remains active after the engine
shuts down. The AWL will flash 20 seconds before the shutdown occurs. The RSL will flash 10
seconds before shutdown occurs. The AWL will blink until the ignition is turned off to indicate
shutdown has occurred. The ignition switch must be cycled to OFF (wait 10 seconds) and back to
ON before the engine will restart, if shutdown occurs.
All information subject to change without notice. (Rev. 7/03) 5-637SA822 0307 Copyright © 2003 DETROIT DIESEL CORPORATION
-
8/15/2019 12_idle shutdown.pdf
2/4
FEATURES
A Park Brake Switch must be installed (see Figure 5-13). Idle Shutdown Timer operates with a
digital input configured as a park brake and switched to battery ground. The time can range from
1 to 1000 seconds (approximately 16 minutes).
Figure 5-13 Park Brake Digital Input
Idle Shutdown Override - Optional
Idle Shutdown Override allows the operator to override the idle shutdown to keep the engine
idling if this feature is enabled.
If the accelerator pedal has been pressed or the park brake has been released, the conditions for the
idle shutdown are no longer valid. The shutdown conditions must be met to reinitialize the counter.
The timer can be reset by one of the following conditions:
Engine Shutdown override button has been pressed
Clutch pedal has been pressed
Service brake has been pressed
5-64 All information subject to change without notice. (Rev. 7/03)7SA822 0307 Copyright © 2003 DETROIT DIESEL CORPORATION
-
8/15/2019 12_idle shutdown.pdf
3/4
MBE ELECTRONIC C ONTROLS APPLICATION AND INSTALLATION
Vehicle Power Shutdown - Optional
Vehicle Power Shutdown is used with Idle Timer Shutdown or Engine Protection Shutdown.
After the idle timer times out or engine protection shuts the engine down, the Vehicle Power
Shutdown relay shuts down the rest of the electrical power to the vehicle.
A Vehicle Power Shutdown relay can be installed to shutdown all electrical loads when the
engine is shutdown (see Figure 5-14). The engine will shutdown after the specified idle time and
will reset the relay (ignition circuit).
Figure 5-14 Vehicle Power Shutdown RelayAll electrical loads that should be turned OFF when the engine shuts down should be wired
through this relay.
Shutdown on VSG - Optional
This option, when enabled, allows the engine to be shutdown when operating on VSG when the
conditions are met for the Idle Timer Shutdown.
Maximum Engine Load Shutdown — Optional
This option, when enabled, allows the setting of a maximum load above which idle shutdown is
disabled.
All information subject to change without notice. (Rev. 7/03) 5-657SA822 0307 Copyright © 2003 DETROIT DIESEL CORPORATION
-
8/15/2019 12_idle shutdown.pdf
4/4
FEATURES
5.8.2 PROGRAMMING REQUIREMENTS AND FLEXIBILITY
To program the Idle Shutdown timer, the digital input listed in Table 5-43 must be configured.
Description Pin Type Setting Default Parameter ID
Park Brake 21/16 Digital Input 0 = Disabled
1 = Enabled 1 1 13 07
Table 5-43 Idle Shutdown Timer Digital Input
The Idle Shutdown timer options listed in Table 5-44 can be programmed by VEPS or minidiag2.
Parameter Description Choice / Range Default Parameter
ID
IDLE SHUTDOWN
ENABLED
Enables or Disables the Idle
Shutdown feature.
0 = Disable
1 = Enable 0 1 02 01
IDLE SHUTDOWN TIME
(MIN)
The amount of engine idle time
that is allowed before the Idle
Shutdown feature stops fueling
the engine.
1 to 1000 seconds 60 sec 1 02 02
ENABLED VSG
SHUTDOWN
Enables or disables the Idle Timer
Shutdown feature when operating
on the Variable Speed Governor.
0 = Disable
1 = Enable 0 1 02 03
VSG SHUTDOWN TIME
The amount of engine idle time
that is allowed before the idle
shutdown feature stops fueling
the engine.
1 to 1000 seconds 60 sec 1 02 04
Time for AWL to flash Time the AWL will flash before
the shutdown occurs 3–120 sec 20 sec 1 02 06
Time for RSL to flash Time the RSL will flash before the
shutdown occurs 3–120 sec 10 sec 1 02 07
MIN COOLANT TEMP
FOR SHUTDOWN
Minimum coolant temperature
before an idle shutdown will occur -40 C to 200 C -10 C 1 02 08
ENABLE IDLE/VSG
SHUTDOWN OVERRIDE
Enables/disables override of Idle
or VSG Shutdown
0 = Disable
1 = Enable 1 1 02 09
Table 5-44 Idle Shutdown Timer Programming Options