Trends in Energy Codes
Shawn MartinShawn MartinPlumbing Mechanical and Fuel Gas (PMG)International Code Council
HVACR and Plumbing WorkshopMarch 25, 2010
-
Topics
• About the ICC• Model Codes• International Energy Conservation • International Energy Conservation
Code Fundamentals• Trends in the IECC
-
About the ICCAbout the ICC
Who we are and what we do.
3
-
VISION:To protect the health, safety and welfare of people by creating better buildings and safer communities
NotNot--forfor--profit Memberprofit Member--Driven AssociationDriven Association
•• 50,000 members50,000 members•• 350+ chapters350+ chapters•• 300+ staff300+ staff
-
ICC - BUILT ON A SOLID FOUNDATION
� Two centuries of collective experience
� A history of support for public safety
BOCA
for public safety � Widespread
recognition and reliance throughout the U.S. and the world.
ICBO
SBCCI
ICC
5
-
ICC’s Products and Activities
Standards
Laboratory
Accreditation
Education &
6
Code Development
Product Certification
Education & Certification
-
ICC’s Family of Building Codes
• International Building Code (IBC)• International Residential Code (IRC)• International Fire Code (IFC)• International Energy Conservation Code (IECC)• International Plumbing Code (IPC)• International Private Sewage Disposal Code (IPSDC)• International Private Sewage Disposal Code (IPSDC)• International Mechanical Code (IMC)• International Fuel Gas Code (IFGC)• International Wildland-Urban Interface Code (IWUIC)• International Existing Building Code (IEBC)• International Property Maintenance Code (IPMC)• International Zoning Code (IZC)• International Green Construction Code (IGCC)
7
-
Model CodesModel Codes
8
-
Building Codes Defined
“Set of standards established and enforced by local government for the structural safety of buildings.”
Princeton University WordNet
“Gangster who built world's tallest log cabin”, Telegraph, March 7, 2007
“A set of rules that specify the minimum acceptable level of safety for constructed objects such as buildings and nonbuilding structures.”
Wikipedia
9
-
Building Codes in the U.S.
U.S. Constitution’s Tenth Amendment gives states rights to legislate to protect:� Public health � Safety� Welfare
10
-
State Adoptions and Delegations
Colorado Virginia
11
� No two states are alike� Can be pre-empted and delegated� 40,000+ political subdivisions enforce
codes
-
What is a Model Code?
� A building code that is developed and maintained by an organization independent of the jurisdiction responsible for enacting the building code.� No force of law – must be adopted by jurisdiction.� Avoids “Reinventing the Wheel” in each state.� Involves nationwide experts to reflect diverse views and state of
the art.� Utilizes consensus development process� Open� Transparent� Balance of Interest� Due Process
12
-
Code ChangesSubmitted
Code Development
Code ChangesPosted
Final ActionHearing
New EditionPublished
ICC CODE DEVELOPMENTDevelopment
Hearing
Public CommentsSought on PublicHearing Results
Public CommentsPosted
Public Hearing Results Posted
DEVELOPMENTCYCLE
-
Local Amendments
� Virtually all governmental entities that adopt a model code amend the document.
� State or local code committees for the jurisdiction review the model code with respect to:� Specific local conditions and needs� Local building practices� Local materials available� Union rules and requirements� Political considerations
14
-
International Energy Conservation Code ®Conservation CodeFundamentals
15
-
History of the IECC
� Original code known as the Model Energy Code (MEC) developed by CABO, BOCA, ICBO, NCSBCS, and SBCCI under a DOE contract in 1983.� MEC Editions released in 1983, 1986,1989, 1992, 1993, and � MEC Editions released in 1983, 1986,1989, 1992, 1993, and
1995.
� Title changed to the International Energy Conservation Code (IECC) in 1998 with the formation of ICC.� IECC Editions released in 1998, 2000, 2003, 2006, 2009
� ICC’s International Energy Conservation Code (IECC) is now the most widely adopted energy code in the world.
16
-
International Energy Conservation Code ® - Scope
Encourages energy conservation through efficiency in envelope through efficiency in envelope design, mechanical systems, lighting systems and the use of new materials and techniques.
-
Scope
� The IECC® applies to:
� Residential Buildings� One- and Two-family dwellings, Townhomes (not-IRC buildings)� Multifamily dwellings three-stories or less in height
� Commercial Buildings� Multifamily dwellings four stories or greater in height
� New Buildings� Additions, Alterations, Renovations, & Repairs
-
Residential Compliance Process
Must the project comply with the IECC?
Insulation, Air Leakage, Lighting & Building Systems
Performance Path
PrescriptivePath
Building Thermal Envelope and Electrical
19
Envelope and Electrical
Simulated Performance Alternative
R-value Computation
UA Alternative
Total UA Alternative
Document Compliance with IECC
Field Inspection
Plan Review
-
Regionalization in 2009
20
-
Regionalization in 2003
21
-
� Intended to work hand-in-hand� Tables are NOT identical� Simulated Performance option is not in IRC� Vapor Retarders are in Chapter 6 – NOT IECC
IECC’s relationship with the IRC
� Vapor Retarders are in Chapter 6 – NOT IECC
Workbook Page 3
22
Vapor Retarders
2006 IRC 2006 IECC 2009 IRC 2009 IECC
No Yes Yes No
-
2006 to 2009 Aggregate Improvement
Preliminary estimates from U.S. DOE suggest the 2009 IECC will be at least 18 percent and possibly even 22 percent more energy efficient than the 2006 IECC
David Rodgers, Deputy Assistant Secretary, U.S. DOE-EERE, statements before Committee on Energy and Commerce, Subcommittee on Energy and Air Quality, U.S. House of Representatives, July 17, 2008.
23
-
Trend 1Trend 1
Expanded adoption.
24
-
Residential BuildingsIECC® State-wide Adoptions
WA
OR
AK
ID
MT
WY
NVUT CO KS
NE
ND
SD WI
MN
IA
MOKY
MI
IL IN OH
NY
VAMA/ CT/ RI
MEVT / NH
PA
WVHI
2003 IECC or equivalent
2000/01 IECC or equivalent
1998 IECC or less
2009 IECC or equivalent
2006 IECC or equivalent
CAAZ NM
TX
OK AR
LA
KYTN
VA
NCSC
GAALMS
FL
MD/DE/ NJ
JANUARY 2009
DC
HI
No Statewide Energy Code
-
International Energy Conservation Code® - Federal Citations
� National private and Federal housing initiatives� Energy Independence & Security Act of 2007
(EISA)� Energy Conservation & Production Act, as
amended� National benchmark for single family homes and
townhomes� National benchmark for low-rise condominiums
and apartments
� Manufactured Housing (HUD 24 CFR 3280)� Energy Efficient Mortgage Programs (FHA, VA,
Fannie & Freddie)
-
ARRA (Stimulus Bill)
American Recovery and Reinvestment Act of 2009� Contains language requiring a plan to adopt the
2009 IECC or better-residential/ 2007 ASHRAE 90.1 or better-commercial.90.1 or better-commercial.� Condition for qualifying for $ 3.1 billion in State Energy
Program funds� Stimulus also funds EISA Block Grants, which has specific
language authorizing grants to develop, implement and adopt and enforce, building codes
-
ARRA: Reaching full Compliance
� Stimulus requires both a plan for active training an enforcement, and annual measurement of percent compliance to reach 90% by 2017.� Much of the technology, construction methods, test methods, and
some of the products are new, and both builders and contractors and code officials will need training to achieve full compliance.code officials will need training to achieve full compliance.
� The stimulus requires a plan, and provides funds.
-
Trend 2Trend 2
Increases in mandatory fenestration and insulation values.
29
-
2006 to 2012 Mandatory Fenestration Requirements
Climate Zone FenestrationU-Factor
Glazed Fenestration SHGC
2006 2009 P2012* 2006 2009 P2012*
1 1.20 1.2 NR 0.40 0.30 0.30
2 0.75 0.65 0.50 0.40 0.30 0.302 0.75 0.65 0.50 0.40 0.30 0.30
3 0.65 0.50 0.40 0.40 0.30 0.30
4 0.40 0.35 0.35 NR NR NR
5 & Marine 4 0.35 0.35 0.32 NR NR NR
6 0.35 0.35 0.32 NR NR NR
7 & 8 0.35 0.35 0.32 NR NR NR
* Proposed changes for 2012
-
2006 to 2012 Mandatory Insulation Requirements
Climate Zone Wood Frame WallR-Value
Basement Wall R-Value
2006 2009 P2012* 2006 2009 P2012*
1 13 13 13 0 0 0
2 13 13 13 0 0 0
3 13 13 13 0 5/13 5/13
4 13 13 20 10/13 10/13 10/13
5 & Marine 4 19 20 or 13+5
20 or 13+5
10/13 10/13 10/13
6 19 20 or 13+5
20+5 or 13+10
10/13 15/19 15/19
7 & 8 21 21 20+5 or 13+10
10/13 15/19 15/19
* Proposed changes for 2012
-
Trend 3Trend 3
More extensive efforts to plug leakage points in the envelope.
32
-
New Air Leakage Requirements in the 2009 Version
� Attic hatches and doors� Weatherstripping� Equivalent insulation� Retainer for loose fill
� Rim joist junctions� Air tightness verification� Test at < 7 ACH at 50 Pa
OR� Rigorous visual
inspection
-
New Air Leakage Requirements in the 2009 Version
� Wood-Burning Fireplaces� Use gasketed doors� Draw combustion air
from exterior of building from exterior of building
-
Mechanical Ventilation Sealing
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the system is not operatingoperating
-
Trend 4Trend 4
Improved controls for HVAC systems.
36
-
Programmable Thermostats in 2009
� For forced-air heating systems� Must be capable to set back or temporarily
operate the system to maintain zone temperatures down to 55°F or up to 85°Ftemperatures down to 55°F or up to 85°F
37
-
Trend 5Trend 5
Enhanced duct and system sealing.
38
-
Duct Tightness Verification in 2009
Post construction test:•
-
Duct Tightness Verification in 2009
Rough-in test:• < 6 cfm per 100 ft² of
conditioned floor area at 25 Pa across the entire 25 Pa across the entire system, including the air handler enclosure, or
•
-
Trend 6Trend 6
Increased emphasis on equipment sizing and efficiency.
41
-
Equipment Sizing
• Per IRC Section M1401.3• Sizing in accordance with • Sizing in accordance with
ACCA Manual S based on building loads calculated in accordance with ACCA Manual J.
-
2012 IECC Proposal EC 121 (Disapproved in first hearing)
43
-
2012 EC-13 Proposal (AS)
� 404.2 Cooling equipment. � Zone 1 & 2: Vapor compression air conditioning SEER shall be at least
16.0 and EER at least 12.5. � Zone 3: Vapor compression air conditioning SEER shall be at least
15.0 and EER at least 12.5.
� 404.2.3 Future updates to federal manufacturing standards. � 404.2.3 Future updates to federal manufacturing standards. � If applicable Federal manufacturing standards as specified in 10 CFR
430 are updated to establish new efficiency requirements, equipment efficiency requirements in this section shall be improved by a percentage equivalent to the percentage improvement from the efficiency required by 10 CFR 430 as of January 1, 2011 to the efficiency required by 10 Code of Federal Regulations 430 at the date of plan check approval.
44
-
Trend 7Trend 7
Move toward more wholistic views of sustainability.
45
-
Cooperative effort launched in 2009 to develop a code overlay for commercial applications.
� Best chance of true enforcement and widespread adoption.
� Covers energy, water efficiency, materials, emissions, IEQ, site preservation, etc.
International Green Construction Code
Covers energy, water efficiency, materials, emissions, IEQ, site preservation, etc.
First version released in March, 2010 and currently open for public comment.
-
IgCC Compliance Paths
� Alternate means of compliance provided in some cases.� Example: IECC – comply with commercial building
requirements for energy efficiency OR ASHRAE Standard 90.1� IgCC Energy Chapter (Chapter 6)
Mandatory Provisions (many from
IECC)
Prescriptive Compliance
Performance Based
Compliance
-
TANEU Defined
TOTAL ANNUAL NET ENERGY USE. A ratio representing the energy performance of the proposed design compared to the energy performance of a standard reference design.
TANEU = 75 x (PD – RE - WE) / RD
Where:PD = Proposed Design energy useRE = Renewable Energy savingsRD = Standard Reference Design energy useWE= Waste Energy recovery savings
PD, RE, and RD shall all be expressed in consistent units of energy on a total annual basis.
-
TANEU Thresholds
100
7770
6380
100
120
63
0
20
40
60
2006 IECC 2009 IECC IgCC Prescriptive IgCC Enhanced
-
National Green Building Standard
� ICC and NAHB Collaboration � Consensus Process Begun: April
2007� Consensus Committee Included:
� Industry – Builders, Architects, Manufacturers
� Government – EPA, DOE, State
50
� Government – EPA, DOE, State & City Building Officials
� Stakeholders – USGBC, Trade Associations
� ANSI Approved 12/2008� Includes Single-Family, Multi-
Family, Remodeling and Site Development
� Bronze, Silver, Gold, and Emerald Thresholds
� Consistent with ICC Language
-
Provisions of Chapter 7
� 701.1 – Buildings can comply with either the performance or prescriptive energy paths provided in the standard. This section also provides guidelines for energy efficiency specifically related to renovations and additions.
51
� 701.1.1 – Minimum Performance Path Requirements � Must exceed IECC minimum performance
by 15%� Must include at least 2 practices from
Section 704
27
-
NGBS Mandatory Fenestration Requirements (Mandatory)
Climate Zone
FenestrationU-Factor
Glazed Fenestration
SHGC
2009 NGBS 2009 NGBS
1 1.2 0.65 0.30 0.40
2 0.65 0.65 0.30 0.40
3 0.50 0.40 0.30 0.40
4 0.35 0.35 NR NR
5 & Marine 4
0.35 0.35 NR NR
6 0.35 0.35 NR NR
7 & 8 0.35 0.35 NR NR
-
Current Air Conditioner SEER Ratings
-
NGBS Air Conditioner and Heat Pump Cooling Credit
Climate Zone
1 2 3 4 5 6-8
POINTS
> 14 SEER 8 6 2 2 1 1> 14 SEER 8 6 2 2 1 1
> 15 SEER 12 10 4 3 2 2
> 17 SEER 18 14 6 4 3 3
>19+ SEER 24 18 8 4 3 3
-
Recommended Resources
Sustainable Construction : Green Building Design and Delivery , 2nd edition
55
ASHRAE GreenGuide : The Design,Construction , and Operation of Sustainable Buildings, 2nd edition
-
Recommended Resources
Green Building Guide lines : Meeting the Dem and for Low -Energy, Resource –Efficient Homes ©, 5th Edition
56
-
Shawn MartinDirector of Industry RelationsPlumbing Mechanical and Fuel Gas (PMG)International Code Council888-422-7233 x 7736
QUESTIONS?
888-422-7233 x [email protected]@iccsafe.org
57
-
Prescriptive Duct Insulation Progression