1/2 Elima-Matic Bolted Metal E5 Service & Operating Manual …aaproduct.com/images/datasheets/E5-...
Transcript of 1/2 Elima-Matic Bolted Metal E5 Service & Operating Manual …aaproduct.com/images/datasheets/E5-...
Ver
sa-M
atic
E5 Metal Pumps• Aluminum• Stainless Steel• Alloy C
1/2" Elima-Matic Bolted Metalwith Metallic and Non-Metallic Center Sections E5
VERSA-MATIC® • Warren Rupp, Inc. • A Unit of IDEX Corporation 800 North Main Street, Mansfield, OH 44902 USA • Phone: (419) 526-7296 • www.versamatic.com
© Copyright 2014 Warren Rupp, Inc. All rights reserved
1: P
UMP
SPEC
S2:
INST
AL &
OP
3: E
XP V
IEW
4: W
ARRA
NTY
Serv
ice
& O
per
ati
ng
Ma
nu
al
Orig
inal
Inst
ruct
ions
e5mdlCsm-rev0314www.versamatic.com
IMPORTANT
Read the safety warnings and instructions in this manual before pump installation and start-up. Failure to comply with the recommendations stated in this manual could damage the pump and void factory warranty.
When used for toxic or aggressive fluids, the pump should always be flushed clean prior to disassembly.
Airborne particles and loud noise hazards. Wear eye and ear protection.
Before maintenance or repair, shut off the compressed air line, bleed the pressure, and disconnect the air line from the pump. Be certain that approved eye protection and protective clothing are worn at all times. Failure to follow these recommendations may result in serious injury or death.
To be fully groundable, the pumps must be ATEX Compliant. Refer to the nomenclature page for ordering information.
Optional 8 foot long (244 centimeters) Ground Strap is available for easy ground connection.
To reduce the risk of static electrical sparking, this pump must be grounded. Check the local electrical code for detailed grounding instruction and the type of equipment required.
Refer to nomenclature page for ordering information.
When the pump is used for materials that tend to settle out or solidify, the pump should be flushed after each use to prevent damage. In freezing temperatures the pump should be completely drained between uses.
Before pump operation, inspect all fasteners for loosening caused by gasket creep. Retighten loose fasteners to prevent leakage. Follow recommended torques stated in this manual.
CAUTION
WARNING
Nonmetallic pumps and plastic components are not UV stabilized. Ultraviolet radiation can damage these parts and negatively affect material properties. Do not expose to UV light for extended periods of time.
In the event of diaphragm rupture, pumped material may enter the air end of the pump, and be discharged into the atmosphere. If pumping a product that is hazardous or toxic, the air exhaust must be piped to an appropriate area for safe containment.
This pump is pressurized internally with air pressure during operation. Make certain that all fasteners are in good condition and are reinstalled properly during reassembly.
Take action to prevent static sparking. Fire or explosion can result, especially when handling flammable liquids. The pump, piping, valves, containers and other miscellaneous equipment must be properly grounded.
Safety Information
Grounding the Pump
WARNINGTake action to prevent static sparking. Fire or explosion can result, especially when handling flammable liquids. The pump, piping, valves, containers or other miscellaneous equipment must be grounded.
WARNINGPump not designed, tested or certified to be powered by compressed natural gas. Powering the pump with natural gas will void the warranty.
Use safe practices when liftingkg
UNIVERSAL ALL AODD
e5mdlCsm-rev0314www.versamatic.com
Table of Contents
SECTION 1: PumP SPECIfICaTIONS ................1 •Nomenclature •Performance •Materials •DimensionalDrawings
SECTION 2: INSTallaTION & OPEraTION ......5 •PrincipleofPumpOperation •TypicalInstallationGuide •Troubleshooting
SECTION 3: ExPlOdEd VIEw ...........................8 •CompositeDrawings •PartsList •MaterialsCode
SECTION 4: warraNTy & CErTIfICaTES ....10 •Warranty •CEDeclarationofConformity-Machinery
Universal*
1: P
UMP
SPEC
S2:
INST
AL &
OP
3: E
XP V
IEW
4: W
ARRA
NTY
e5mdlCsm-rev03141 • Model E5 Metallic Bolted www.versamatic.com
Explanation of Pump Nomenclature
Model Pump Size Wetted Parts Non-Wetted Parts Diaphragm MaterialE Elima-Matic 6 1/4" A Aluminum A Aluminum 1 NeopreneUUltra-Matic 8 3/8" C Cast Iron S Stainless Steel 2NitrileVV-Series 5 1/2" S Stainless Steel PPolypropylene 3 (FKM)FluorocarbonRE AirVantage 7 3/4" H Alloy C G Groundable Acetal 4EPDM 1 1" PPolypropylene ZPTFE-coatedAluminum 5PTFE 41-1/4"or1-1/2" K Kynar JNickel-platedAluminum 6Santoprene(XL) 2 2" G Groundable Acetal C Cast Iron 7 Hytrel 3 3" B Aluminum (screen mount) QEpoxy-CoatedAluminum 9 Geolast
Diaphragm Series Valve Ball Material Valve Seat/Valve Seat O-Ring Material Construction DesignR Rugged 1Neoprene 1 Neoprene 9 BoltedDDome 2 Nitrile 2Nitrile 0 ClampedXThermo-Matic 3(FKM)Fluorocarbon 3(FKM)FluorocarbonTTef-Matic(2-piece) 4EPDM 4EPDMBVersa-Tuff(1-piece) 5PTFE 5PTFEFFUSION(one-piece 6Santoprene(XL) 6Santoprene(XL)integrated plate) 7 Hytrel 7 Hytrel 8 Polyurethane 8Polyurethane 9 Geolast 9 Geolast A Acetal AAluminumw/PTFEO-Rings S Stainless Steel SStainlessSteelw/PTFEO-Rings CCarbonSteelw/PTFEO-Rings HAlloyCw/PTFEO-Rings TPTFEEncapsulatedSiliconeO-Rings
Your Serial #: (fill in from pump nameplate) _____________________________________
VERSA-MATIC® MODEL IDENTIFICATION CODES
X X X X X X X X X X - X X X
Model
Pump Size
Wetted Parts
Non-Wetted Parts
Diaphragm Material
Diaphragm Series
Valve Ball Material
Valve Seat Material/Valve Seat O-ring Material
Construction Design
Revision Level
Options (if applicable)
Model Pump Size Wetted Parts Non-Wetted Parts Diaphragm MaterialE Elima-Matic 6 1/4" A Aluminum A Aluminum 1 Neoprene U Ultra-Matic 8 3/8" C Cast Iron S Stainless Steel 2 Buna-N V V-Series 5 1/2" S Stainless Steel P Polypropylene 3 (FKM) Fluorocarbon 7 3/4" H Hastelloy C G Groundable Acetal 4 Nordel 1 1" P Polypropylene Z PTFE-coated Aluminum 5 PTFE 4 1-1/4" or 1-1/2" K Kynar J Nickel-plated Aluminum 6 XL 2 2" G Groundable Acetal C Cast Iron 7 Hytrel 3 3" B Aluminum (screen mount) Q Epoxy-Coated Aluminum 9 Geolast
Diaphragm Series Valve Ball Material Valve Seat/Valve Seat O-ring Material Construction DesignR Rugged 1 Neoprene 1 Neoprene 9 Bolted D Dome 2 Buna-N 2 Buna-N 0 Clamped X Thermo-Matic 3 (FKM) Fluorocarbon 3 (FKM) Fluorocarbon T Tef-Matic (2-piece) 4 Nordel 4 Nordel B Versa-Tuff (1-piece) 5 PTFE 5 PTFE F FUSION (one-piece 6 XL 6 XL integrated plate) 7 Hytrel 7 Hytrel 8 Polyurethane 8 Polyurethane 9 Geolast 9 Geolast A Acetal A Aluminum w/ PTFE O-rings S Stainless Steel S Stainless Steel w/ PTFE O-rings C Carbon Steel w/ PTFE O-rings H Hastelloy C w/ PTFE O-rings T PTFE Encapsulated Silicone O-rings
Model #:
__ __ __ __ __ __ __ __ __ __ __ __ __(fill in from pump nameplate)
Your Model #:
UNIVERSAL TO ALL VM
1: P
UMP
SPEC
S
e5mdlCsm-rev0314Model E5 Metallic Bolted • 2www.versamatic.com
materials
Material Profile: Operating Temperatures:Max. Min.
Conductive Acetal: Tough, impact resistant, ductile. Good abrasionresistanceandlowfrictionsurface.Generallyinert,withgoodchemicalresistanceexceptforstrongacidsandoxidizingagents.
190°F88°C
-20°F-29°C
EPDM:Showsverygoodwaterandchemicalresistance.Haspoor resistance to oils and solvents, but is fair in ketones and alcohols.
280°F138°C
-40°F-40°C
FKM:(Fluorocarbon)Showsgoodresistancetoawiderange of oils and sovents; especially all aliphatic, aromatic and halogenated hydrocarbons, acids, animal and vegetable oils. Hotwaterorhotaqueoussolutions(over70°F)willattackFKM.
350°F177°C
-40°F-40°C
Hytrel®: Good on acids, bases, amines and glycols at room temperatures only.
220°F104°C
-20°F-29°C
Neoprene: All purpose. Resistance to vegetable oils. Generally not affected by moderate chemicals, fats, greases and many oilsandsolvents.Generallyattackedbystrongoxidizingacids,ketones, esters and nitro hydrocarbons and chlorinated aromatic hydrocarbons.
200°F93°C
-10°F-23°C
Nitrile: Generalpurpose,oil-resistant.Showsgoodsolvent,oil,waterandhydraulicfluidresistance.ShouldnotbeusedwithhighlypolarsolventslikeacetoneandMEK,ozone,chlorinatedhydrocarbons and nitro hydrocarbons.
190°F88°C
-10°F-23°C
Nylon: 6/6Highstrengthandtoughnessoverawide temperaturerange.Moderatetogoodresistancetofuels,oilsand chemicals.
180°F82°C
32°F0°C
Polypropylene:Athermoplasticpolymer.Moderatetensileandflexstrength.Resistsstongacidsandalkali.Attackedbychlorine,fumingnitricacidandotherstrongoxidizingagents.
180°F82°C
32°F0°C
PVDF:(PolyvinylideneFluoride)Adurablefluoroplasticwithexcellentchemicalresistance.ExcellentforUVapplications.High tensile strength and impact resistance.
250°F121°C
0°F-18°C
Santoprene®:Injectionmoldedthermoplasticelastomerwithnofabriclayer.Longmechanicalflexlife.Excellentabrasionresistance.
275°F135°C
-40°F-40°C
UHMW PE: A thermoplastic that is highly resistant to a broad rangeofchemicals.Exhibitsoutstandingabrasionandimpactresistance,alongwithenvironmentalstress-crackingresistance.
180°F82°C
-35°F-37°C
Urethane:Showsgoodresistancetoabrasives.Haspoorresistance to most solvents and oils.
150°F66°C
32°F0°C
Virgin PTFE:(PFA/TFE)Chemicallyinert,virtuallyimpervious.VeryfewchemicalsareknowntochemicallyreactwithPTFE;moltenalkalimetals,turbulentliquidorgaseousfluorineandafewfluoro-chemicalssuchaschlorinetrifluorideoroxygendifluoridewhichreadilyliberatefreefluorineatelevated temperatures.
220°F104°C
-35°F-37°C
Maximum and Minimum Temperatures are the limits for which these materials can be operated. Temperatures coupled with pressure affect the longevity of diaphragm pump components. Maximum life should not be expected at the extreme limits of the temperature ranges.
Metals:Alloy C:EqualtoASTM494CW-12M-1specificationfornickelandnickelalloy.Stainless Steel: EqualtoorexceedingASTMspecificationA743CF-8Mforcorrosionresistant iron chromium, iron chromium nickel and nickel based alloy castings for general applicaitons. Commonly referred to as 316 Stainless Steel in the pump industry.
For specific applications, always consult the Chemical Resistance Chart.
CAUTION! Operating temperature limitations are as follows:
Ambient temperature range -20Cto+40CProcess temperature range -20Cto+80Cformodelsratedascategory1equipment -20cto+100Cformodelratedascategory2equipmentInaddition,theambienttemperaturerangeandtheprocesstemperaturerangedonotexceedtheoperatingtemperaturerangeoftheappliednon-metallicpartsaslistedinthemanualsofthepumps.
afTErmarKET ParTS
Pumper Parts is your single source for parts that fit Air-Operated Double Diaphragm (AODD) pumps
• Wilden®
• ARO®
• Yamada®
RIGHT PART, RIGHT NOW
designed to perform equal to or greater than original equipment manufacture.
Phone: (419) 526-7296info@pum perparts.comwww.pumperparts.com
Pumper Parts and its products are not affiliated with any of the original equipment manufacturers referenced herein. All original equipment manufacturers’ names, colors, pictures, descriptions and part numbers are used for identification purposes only. Pumper Parts® is a registered trade name of IDEX Corporation. All other trademarks, registered trademarks and product names are the property of their respective owners. Yamada® is a registered trademark of Yamada Corporation. ARO® is a registered trade name of Ingersoll-Rand Company. Wilden® is a registered trade name of Wilden Pump and Engineering Company, a Dover Resources Company.
MODEL SPECIFIC UNIVERSAL ALL AODD
1: P
UMP
SPEC
S
e5mdlCsm-rev03143 • Model E5 Metallic Bolted www.versamatic.com
Performance
Meters Feet
Disc
harg
e Hea
d in
PSI
2 106
0
100
90 80 70 60 50 40 30 20 10
0
240 220 200 180 160 140 120 100
80 60 40 20
0
75 70 65 60 55 50 45 40 35 30 25 20 15 10
5 0
1284
40
0
5 10 15 20 25 30 35 45 50Capacity in Liters Per Minute
Capacity in U.S. Gallons Per Minute
Displacement Per Stroke, 0.022 Gal. (0.08 L)
48
12
2 AIR CONSUMPTION IN SCFMAIR PRESSURE IN PSI
SCFM M3/HR 2 3.4 4 6.8 8 13.6 12 20.4
0
1
2
3
4
5
6
7
BAR
Disc
harg
e Hea
d in
PSI
2 106
0
100
90 80 70 60 50 40 30 20 10
0 Meters Feet
240 220 200 180 160 140 120 100
80 60 40 20
0
75 70 65 60 55 50 45 40 35 30 25 20 15 10
5 0 0
1
2
3
4
5
6
7
BAR 1284
40
0
5 10 15 20 25 30 35 45 50Capacity in Liters Per Minute
Capacity in U.S. Gallons Per Minute
Displacement Per Stroke, 0.019 Gal. (0.08 L)
48
12
2 AIR CONSUMPTION IN SCFMAIR PRESSURE IN PSI
SCFM M3/HR 2 3.4 4 6.8 8 13.6 12 20.4
E5 1/2" Bolted MetalRubber and TPE Fitted
Flow Rate Adjustable to . . . . . . . . . .0-12gpm(45.4lpm)Port Size Suction . . . . . . . . . . . . . . . . . . . . . . . .1/2"NPT Discharge . . . . . . . . . . . . . . . . . . . . . .1/2"NPTAir Inlet . . . . . . . . . . . . . . . . . . . . . . . .3/8"NPTAir Exhaust . . . . . . . . . . . . . . . . . . . .3/8"NPTSuction Lift Dry . . . . . . . . . . . . . . . . . . . . . . . . . 13' (3.9 m) Wet. . . . . . . . . . . . . . . . . . . . . . . . . 22'(6.7m)Max Solid Size(Diameter) . . . . . . . . . . . . . . . . . . . . . . . . . 1/16" (1.6 mm)Max Noise Level . . . . . . . . . . . . . . . 84 dB(A)Shipping Weights Aluminum . . . . . . . . . . . . . . . . . .11 lbs (3.9 kg) Stainless. . . . . . . . . . . . . . . . . . .17lbs(7.7kg) Alloy C . . . . . . . . . . . . . . . . . . . .17lbs(7.7kg)
E5 1/2" Bolted MetalPTFE Fitted
Flow Rate Adjustable to . . . . . . . . . . 0-11gpm(41.6lpm)Port Size Suction . . . . . . . . . . . . . . . . . . . . . . . .1/2"NPT Discharge . . . . . . . . . . . . . . . . . . . . . .1/2"NPTAir Inlet . . . . . . . . . . . . . . . . . . . . . . . .3/8"NPTAir Exhaust . . . . . . . . . . . . . . . . . . . .3/8"NPTSuction Lift Dry . . . . . . . . . . . . . . . . . . . . . . . . . 12' (3.6 m) Wet. . . . . . . . . . . . . . . . . . . . . . . . . 22'(6.7m)Max Solid Size(Diameter) . . . . . . . . . . . . . . . . . . . . . . . . . 1/16" (1.6 mm)Max Noise Level . . . . . . . . . . . . . . . 87dB(A)Shipping Weights Aluminum . . . . . . . . . . . . . . . . . .11 lbs (3.9 kg) Stainless. . . . . . . . . . . . . . . . . . .17lbs(7.7kg) Alloy C . . . . . . . . . . . . . . . . . . . .17lbs(7.7kg)
NOTE: Performance based on the following: PTFE fitted pump, flooded suction, water at ambient conditions. The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%.
NOTE: Performance based on the following: PTFE fitted pump, flooded suction, water at ambient conditions. The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%.
1: P
UMP
SPEC
S
e5mdlCsm-rev0314Model E5 Metallic Bolted • 4www.versamatic.com
E5 Metallic Bolted Dimensionsininches(mm dimensions in brackets). The dimensions on this drawing are for reference only. A certified drawing can be requested if physical dimensions are needed.
dimensional drawings
.9524.13
7.39187.73
9.35237.49
1/2" NPTDISCHARGE PORT
1/2" NPTSUCTION PORT
3/8" NPTAIR INLET
1.2531.75
.379.40
10.05255.27
6.25158.75
5.98151.87
4.00101.60
3.2582.55
4.38111.25
5.26133.60
2X 1.1328.70
4X R .143.56
8.39213.21
3/8 " NPTEXHAUST PORT
BOTTOM VIEW
.9524.13
7.39187.73
9.35237.49
1/2" NPTDISCHARGE PORT
1/2" NPTSUCTION PORT
3/8" NPTAIR INLET
1.2531.75
.379.40
10.05255.27
6.25158.75
5.98151.87
4.00101.60
3.2582.55
4.38111.25
5.26133.60
2X 1.1328.70
4X R .143.56
8.39213.21
3/8 " NPTEXHAUST PORT
BOTTOM VIEW
Model Specific
1: P
UMP
SPEC
S
e5mdlCsm-rev03145 • Model E5 Metallic Bolted www.versamatic.com
Air Line
Discharged Fluid
DischargeStroke Suction
Stroke
PrimedFluid
Air-OperatedDoubleDiaphragm(AODD)pumpsarepoweredby compressed air or nitrogen.
The main directional (air) control valve ① distributes compressedairtoanairchamber,exertinguniformpressureover the inner surface of the diaphragm ②. At the same time, theexhaustingair③ from behind the opposite diaphragm isdirectedthroughtheairvalveassembly(s)toanexhaust port ④.
As inner chamber pressure (P1)exceedsliquidchamberpressure (P2), the rod ⑤ connected diaphragms shift together creating discharge on one side and suction on the opposite side. The discharged and primed liquid’s directions arecontrolledbythecheckvalves(ballorflap)⑥ orientation.
The pump primes as a result of the suction stroke. The suctionstrokelowersthechamberpressure(P3) increasing the chamber volume. This results in a pressure differential necessary for atmospheric pressure (P4)topushthefluidthrough the suction piping and across the suction side check valveandintotheouterfluidchamber⑦.
Suction (side) stroking also initiates the reciprocating (shifting, stroking or cycling) action of the pump. The suction diaphragm’s movement is mechanically pulled through its stroke.Thediaphragm’sinnerplatemakescontactwithanactuator plunger aligned to shift the pilot signaling valve. Once actuated, the pilot valve sends a pressure signal to the opposite end of the main directional air valve, redirecting the compressed air to the opposite inner chamber.
Principle of Pump Operation
SAFE AIREXHAUSTDISPOSALAREA
PUMP INSTALLATION AREA
1" DIAMETER AIREXHAUST PIPING
1" DIAMETER AIREXHAUST PIPING
1" DIAMETER AIREXHAUST PIPING
MUFFLER
LIQUIDLEVEL
SUCTIONLINE
LIQUIDLEVEL
SUCTIONLINE
MUFFLER
MUFFLER
SUBMERGED ILLUSTRATION
Pumpcanbesubmergedifthepumpmaterialsofconstructionarecompatiblewiththeliquidbeingpumped.Theairexhaustmust be piped above the liquid level. When the pumped product sourceisatahigherlevelthanthepump(floodedsuctioncondition),pipetheexhausthigherthantheproductsourcetoprevent siphoning spills.
MODEL SPECIFIC
2: IN
STAL
& O
P
e5mdlCsm-rev0314Model E5 Metallic Bolted • 6www.versamatic.com
Installation And Start-Up Locatethepumpasclosetotheproductbeingpumpedaspossible.Keepthesuctionlinelengthandnumberoffittingstoaminimum.Donotreducethesuctionlinediameter.
Air Supply Connectthepumpairinlettoanairsupplywithsufficientcapacityandpressuretoachievedesiredperformance.Apressureregulatingvalveshouldbeinstalledtoinsureairsupplypressuredoesnotexceedrecommendedlimits.
Air Valve Lubrication The air distribution system is designed to operate WITHOUT lubrication. This is the standard mode of operation. If lubrication is desired, install an air line lubricator settodeliveronedropofSAE10non-detergentoilforevery20SCFM(9.4liters/sec.)ofairthepumpconsumes.ConsultthePerformanceCurvetodetermineairconsumption.
Air Line Moisture Waterinthecompressedairsupplymaycauseicingorfreezingoftheexhaustair,causingthepumptocycleerraticallyorstopoperating.Waterintheairsupplycanbereducedbyusingapoint-of-useairdryer.
Air Inlet And Priming Tostartthepump,slightlyopentheairshut-offvalve.Afterthepumpprimes,theairvalvecanbeopenedtoincreaseairflowasdesired.Ifopeningthevalveincreasescyclingrate,butdoesnotincreasetherateofflow,cavitationhasoccurred.Thevalveshouldbeclosedslightlytoobtainthemostefficientairflowtopumpflowratio.
Surge Suppressor
Shut-Off Valve
Pressure Gauge
Drain PortShut-OffValve
CheckValve
Air Inlet
Discharge
Unregulated AirSupply to Surge
Suppressor
Pipe Connection(Style Optional)
Flexible Connector
Flexible Connector
VacuumGauge
Suction
Shut-Off Valve
Drain Port Pipe Connection(Style Optional)
FlexibleConnector
Air Dryer
Filter RegulatorP/N: 020.V107.000
Note: Pipe weight should not be supported by pump connections.
Muffler(Optional Piped Exhaust)
recommended Installation Guide
Available Accessories: 1. Surge Suppressor 2. Filter/Regulator 3. Air Dryer
1
2
3
Note: Surge Suppressor and Pipingmustbesupportedaftertheflexibleconnection.
CAUTIONThe air exhaust should be piped to an area for safe disposition of the product being pumped, in the event of a diaphragm failure.
Principle of Pump Operation
SUBMERGED ILLUSTRATION
UNIVERSAL ALL AODD
2: IN
STAL
& O
P
e5mdlCsm-rev03147 • Model E5 Metallic Bolted www.versamatic.com
Troubleshooting GuideSymptom: Potential Cause(s): Recommendation(s):Pump Cycles Once Deadhead(systempressuremeetsorexceedsair
supply pressure).Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroflow. (Doesnotapplytohighpressure2:1units).
Air valve or intermediate gaskets installed incorrectly. Installgasketswithholesproperlyaligned.Bent or missing actuator plunger. Remove pilot valve and inspect actuator plungers.
Pump Will Not Operate / Cycle
Pumpisoverlubricated. Setlubricatoronlowestpossiblesettingorremove.Unitsaredesignedforlubefreeoperation.Lackofair(linesize,PSI,CFM). Checktheairlinesizeandlength,compressorcapacity(HPvs.cfmrequired).Check air distribution system. Disassembleandinspectmainairdistributionvalve,pilotvalveandpilotvalveactuators.Dischargelineisblockedorcloggedmanifolds. Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping.Deadhead(systempressuremeetsorexceedsairsupply pressure).
Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroflow. (Doesnotapplytohighpressure2:1units).
Blockedairexhaustmuffler. Removemufflerscreen,cleanorde-ice,andre-install.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.Pumpchamberisblocked. Disassembleandinspectwettedchambers.Removeorflushanyobstructions.
Pump Cycles and Will Not Prime or No Flow
Cavitation on suction side. Check suction condition (move pump closer to product).Check valve obstructed. Valve ball(s) not seating properly or sticking.
Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket. Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged. Use heavier valve ball material.
Valve ball(s) missing (pushed into chamber or manifold).
Wornvalveballorvalveseat.Wornfingersinvalveballcage(replacepart).CheckChemical Resistance Guide for compatibility.
Valve ball(s)/seat(s) damaged or attacked by product. Check Chemical Resistance Guide for compatibility.Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.Suction line is blocked. Removeorflushobstruction.Checkandclearallsuctionscreensorstrainers.Excessivesuctionlift. Forliftsexceeding20’ofliquid,fillingthechamberswithliquidwillprimethepumpinmostcases.Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.
Pump Cycles Running Sluggish/Stalling, Flow Unsatisfactory
Over lubrication. Setlubricatoronlowestpossiblesettingorremove.Unitsaredesignedforlubefreeoperation.Icing. Removemufflerscreen,de-ice,andre-install.Installapointofuseairdrier.Clogged manifolds. CleanmanifoldstoallowproperairflowDeadhead(systempressuremeetsorexceedsairsupply pressure).
Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroflow. (Doesnotapplytohighpressure2:1units).
Cavitation on suction side. Check suction (move pump closer to product).Lackofair(linesize,PSI,CFM). Checktheairlinesize,length,compressorcapacity.Excessivesuctionlift. Forliftsexceeding20’ofliquid,fillingthechamberswithliquidwillprimethepumpinmostcases.Airsupplypressureorvolumeexceedssystemhd. Decreaseinletair(press.andvol.)tothepump.Pumpiscavitatingthefluidbyfastcycling.Undersizedsuctionline. Meetorexceedpumpconnections.Restrictiveorundersizedairline. Install a larger air line and connection. Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.Suction line is blocked. Removeorflushobstruction.Checkandclearallsuctionscreensorstrainers.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.Check valve obstructed. Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket.Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.Entrainedairorvaporlockinchamber(s). Purgechambersthroughtappedchamberventplugs.Purgingthechambersofaircanbedangerous.
Product Leaking Through Exhaust
Diaphragmfailure,ordiaphragmplatesloose. Replace diaphragms, check for damage and ensure diaphragm plates are tight.Diaphragmstretchedaroundcenterholeorboltholes. Checkforexcessiveinletpressureorairpressure.ConsultChemicalResistanceChartforcompatibility
withproducts,cleaners,temperaturelimitationsandlubrication.Premature Diaphragm Failure
Cavitation. Enlargepipediameteronsuctionsideofpump.Excessivefloodedsuctionpressure. Movepumpclosertoproduct.Raisepump/placepumpontopoftanktoreduceinletpressure.
Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener.Misapplication(chemical/physicalincompatibility). ConsultChemicalResistanceChartforcompatibilitywithproducts,cleaners,temperaturelimitations
and lubrication.Incorrectdiaphragmplatesorplatesonbackwards,installedincorrectlyorworn.
CheckOperatingManualtocheckforcorrectpartandinstallation.Ensureouterplateshavenotbeenworntoasharpedge.
Unbalanced Cycling Excessivesuctionlift. Forliftsexceeding20’ofliquid,fillingthechamberswithliquidwillprimethepumpinmostcases.Undersizedsuctionline. Meetorexceedpumpconnections.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.Check valve obstructed. Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket.Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.Entrainedairorvaporlockinchamber(s). Purgechambersthroughtappedchamberventplugs.
For additional troubleshooting tips contact After Sales Support at [email protected] or 419-524-8388
UNIVERSAL ALL AODD, EXCEPT FLAP
2: IN
STAL
& O
P
e5mdlCsm-rev0314Model E5 Metallic Bolted • 8www.versamatic.com
Troubleshooting GuideSymptom: Potential Cause(s): Recommendation(s):Pump Cycles Once Deadhead(systempressuremeetsorexceedsair
supply pressure).Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroflow. (Doesnotapplytohighpressure2:1units).
Air valve or intermediate gaskets installed incorrectly. Installgasketswithholesproperlyaligned.Bent or missing actuator plunger. Remove pilot valve and inspect actuator plungers.
Pump Will Not Operate / Cycle
Pumpisoverlubricated. Setlubricatoronlowestpossiblesettingorremove.Unitsaredesignedforlubefreeoperation.Lackofair(linesize,PSI,CFM). Checktheairlinesizeandlength,compressorcapacity(HPvs.cfmrequired).Check air distribution system. Disassembleandinspectmainairdistributionvalve,pilotvalveandpilotvalveactuators.Dischargelineisblockedorcloggedmanifolds. Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping.Deadhead(systempressuremeetsorexceedsairsupply pressure).
Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroflow. (Doesnotapplytohighpressure2:1units).
Blockedairexhaustmuffler. Removemufflerscreen,cleanorde-ice,andre-install.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.Pumpchamberisblocked. Disassembleandinspectwettedchambers.Removeorflushanyobstructions.
Pump Cycles and Will Not Prime or No Flow
Cavitation on suction side. Check suction condition (move pump closer to product).Check valve obstructed. Valve ball(s) not seating properly or sticking.
Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket. Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged. Use heavier valve ball material.
Valve ball(s) missing (pushed into chamber or manifold).
Wornvalveballorvalveseat.Wornfingersinvalveballcage(replacepart).CheckChemical Resistance Guide for compatibility.
Valve ball(s)/seat(s) damaged or attacked by product. Check Chemical Resistance Guide for compatibility.Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.Suction line is blocked. Removeorflushobstruction.Checkandclearallsuctionscreensorstrainers.Excessivesuctionlift. Forliftsexceeding20’ofliquid,fillingthechamberswithliquidwillprimethepumpinmostcases.Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.
Pump Cycles Running Sluggish/Stalling, Flow Unsatisfactory
Over lubrication. Setlubricatoronlowestpossiblesettingorremove.Unitsaredesignedforlubefreeoperation.Icing. Removemufflerscreen,de-ice,andre-install.Installapointofuseairdrier.Clogged manifolds. CleanmanifoldstoallowproperairflowDeadhead(systempressuremeetsorexceedsairsupply pressure).
Increasetheinletairpressuretothepump.Pumpisdesignedfor1:1pressureratioatzeroflow. (Doesnotapplytohighpressure2:1units).
Cavitation on suction side. Check suction (move pump closer to product).Lackofair(linesize,PSI,CFM). Checktheairlinesize,length,compressorcapacity.Excessivesuctionlift. Forliftsexceeding20’ofliquid,fillingthechamberswithliquidwillprimethepumpinmostcases.Airsupplypressureorvolumeexceedssystemhd. Decreaseinletair(press.andvol.)tothepump.Pumpiscavitatingthefluidbyfastcycling.Undersizedsuctionline. Meetorexceedpumpconnections.Restrictiveorundersizedairline. Install a larger air line and connection. Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.Suction line is blocked. Removeorflushobstruction.Checkandclearallsuctionscreensorstrainers.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.Check valve obstructed. Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket.Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.Entrainedairorvaporlockinchamber(s). Purgechambersthroughtappedchamberventplugs.Purgingthechambersofaircanbedangerous.
Product Leaking Through Exhaust
Diaphragmfailure,ordiaphragmplatesloose. Replace diaphragms, check for damage and ensure diaphragm plates are tight.Diaphragmstretchedaroundcenterholeorboltholes. Checkforexcessiveinletpressureorairpressure.ConsultChemicalResistanceChartforcompatibility
withproducts,cleaners,temperaturelimitationsandlubrication.Premature Diaphragm Failure
Cavitation. Enlargepipediameteronsuctionsideofpump.Excessivefloodedsuctionpressure. Movepumpclosertoproduct.Raisepump/placepumpontopoftanktoreduceinletpressure.
Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener.Misapplication(chemical/physicalincompatibility). ConsultChemicalResistanceChartforcompatibilitywithproducts,cleaners,temperaturelimitations
and lubrication.Incorrectdiaphragmplatesorplatesonbackwards,installedincorrectlyorworn.
CheckOperatingManualtocheckforcorrectpartandinstallation.Ensureouterplateshavenotbeenworntoasharpedge.
Unbalanced Cycling Excessivesuctionlift. Forliftsexceeding20’ofliquid,fillingthechamberswithliquidwillprimethepumpinmostcases.Undersizedsuctionline. Meetorexceedpumpconnections.Pumpedfluidinairexhaustmuffler. Disassemblepumpchambers.Inspectfordiaphragmruptureorloosediaphragmplateassembly.Suction side air leakage or air in product. Visuallyinspectallsuction-sidegasketsandpipeconnections.Check valve obstructed. Disassemblethewetendofthepumpandmanuallydislodgeobstructioninthecheckvalvepocket.Checkvalveand/orseatiswornorneedsadjusting. Inspectcheckvalvesandseatsforwearandpropersetting.Replaceifnecessary.Entrainedairorvaporlockinchamber(s). Purgechambersthroughtappedchamberventplugs.
Composite repair Parts drawing
1
2
3
4
5
6
7
8
9
10
11
1213 14
15
16
17
18
19
2021
22
24
25
26
26 27
27
28
29
30
3132
32
33
34
35
35
36
36
FUSION DIAPHRAGM ASSEMBLY
22
21
PTFE 2-PIECE DIAPHRAGM ASSEMBLY
2322
21
24
25
Torque Setting:70 in-lbs.
Torque Setting:70 in-lbs.
Torque Setting:70 in-lbs.
Torque Setting:90 in-lbs.
Torque Setting:90 in-lbs.
Torque Setting:30 in-lbs.
1
2
3
4
5
6
7
8
9
10
11
1213 14
15
16
17
18
19
2021
22
24
25
26
26 27
27
28
29
30
3132
32
33
34
35
35
36
36
FUSION DIAPHRAGM ASSEMBLY
22
21
PTFE 2-PIECE DIAPHRAGM ASSEMBLY
2322
21
24
25
Torque Setting:70 in-lbs.
Torque Setting:70 in-lbs.
Torque Setting:70 in-lbs.
Torque Setting:90 in-lbs.
Torque Setting:90 in-lbs.
Torque Setting:30 in-lbs.
General Model Specific
3: E
XP V
IEW
e5mdlCsm-rev03149 • Model E5 Metallic Bolted www.versamatic.com
Composite repair Parts listAir Valve Assembly
Item # Qty. Description Part Number- 1 ValveBody(includesitems1-11) 031.V004.5521 1 Valve Body PE500A2 1 Valve Spool Assembly
(Includes items 3&4) E500BUBASY3 1 LargeValveSpoolU-Cup P98-104A4 1 SmallValveSpoolU-Cup P98-104AUB5 1 EndCapAssembly(IncludesO-Ring) E500D6 1 ReducingEndCapAssembly(Includes
560.0580.360O-Rings) E500DUBASY7 2 Staple E500F8 1 CTAirDiverter 10-0759 1 AirDiverterPlate E500H
10 1 Air Valve Gasket 360.V003.36011 4 ValveMountingScrews S1004
Center Section AssemblyItem # Qty. Description Part Number
Polypropylene Aluminum12 1 Center Section E501A E501A-SC13 1 PilotSpoolASY(IncludesItem#14) 775.V003.00014 8 PilotSpoolO-Rings 560.023.36015 1 PilotValveSleeveASY(IncludesItem
#16) 755.V003.00016 6 PilotValveSleeveO-Rings 560.033.36017 2 Shaft/PilotRetainer 670.V001.55418 4 RetainerScrew E501C19 1 Muffler VTM-3
Diaphragm Assembly / ElastomersItem # Qty. Description Part Number
TPE/RUBBER PTFE 2-Piece PTFE Fusion20 2 MainShaftO-Ring E502B21 1 MainShaft E502A22 2 Diaphragm "E505xx
(SeeBelowMaterialChart)" E505TF E505F23 2 Back-UpDiaphragm N/A E505N N/A24 2 InnerDiaphragmPlate V199C N/A25 2 OuterDiaphragmPlate SV199B N/A26 4 ValveSeatO-Ring "V110xx
(SeeBelowMaterialChart)" V110HT
27 4 Valve Ball "V111xx (SeeBelowMaterialChart)" V111SS, V111TF
Wet End AssemblyItem # Qty. Description Part Number
Aluminum Stainless Steel Hastelloy28 2 Water Chamber E504A E504S E504H29 16 Water Chamber Bolt SV189D30 16 Water Chamber Washer SV189C31 16 WaterChamberNut SV185B32 4 Valve Seat V110A SV110 HV11033 1 DischargeManifold V196 SV196 HV19634 1 SuctionManifold V197 SV197 HV19735 8 ManifoldBolts FV27AS SV197D36 8 ManifoldWasher SV196C37 8 ManifoldNut(notpictured) N/A SV197E
Elastomer Material SpecificationsMaterial Diaphragm P/N Valve Ball P/N O-Ring P/NNeoprene E505N N/A N/ABunaNitrile E505BN V111BN V110BN
Viton E505VT V111VT V110VTNordel E505ND N/A V110ND
Santoprene E505XL V111TPEXL V110XLHytrel E505FG V111TPEFG N/A
Geolast N/A V111G N/AAcetal N/A V111A N/A
Polyurathane N/A V111PU N/AStainless Steel N/A V111SS N/A
MODEL SPECIFIC
3: E
XP V
IEW
e5mdlCsm-rev0314www.versamatic.com Model E5 Metallic Bolted • 10
written warranty5 - yEar limited Product warranty
Quality System ISO9001 Certified • Environmental Management Systems ISO14001 Certified Versa-Matic warrants to the original end-use purchaser that no product sold by
Versa-Matic that bears a Versa-Matic brand shall fail under normal use and service due to a defect in materialor workmanship within five years from the date of shipment from Versa-Matic’s factory.
~ See complete warranty at http://www.versamatic.com/pdfs/VM%20Product%20Warranty.pdf ~
DATE: August 10, 2011FECHA: DATUM:DATA:DATO:PÄIVÄYS:
AUTHORIZED / APPROVED BY: Approuve par: Aprobado por: Genehmigt von: approvato da: Goedgekeurd door: Underskrift: Valtuutettuna: Bemyndiget av: Autorizado Por:
04/19/2012 REV 07 VMQR 044FM
This product complies with the following European Community Directives: Ce produit est conforme aux directives de la Communauté européenne suivantes: Este producto cumple con las siguientes Directrices de la Comunidad Europea: Dieses produkt erfüllt die folgenden Vorschriften der Europäischen Gemeinschaft: Questo prodotto è conforme alle seguenti direttive CEE: Dir produkt voldoet aan de volgende EG-richtlijnen: Denna produkt överensstämmer med följande EU direktiv: Versa-Matic, Inc., erklærer herved som fabrikant, at ovennævnte produkt er i overensstemmelse med bestemmelserne i Direkktive:Tämä tuote täyttää seuraavien EC Direktiivien vaatimukstet:Dette produkt oppfyller kravene til følgende EC Direktiver:Este produto está de acordo com as seguintes Directivas comunitárias:
MANUFACTURED BY:FABRIQUE PAR:FABRICADA POR:HERGESTELLT VON:FABBRICATO DA:VERVAARDIGD DOOR:TILLVERKAD AV:FABRIKANT:VALMISTAJA:PRODUSENT:FABRICANTE:
DECLARATION DE CONFORMITE • DECLARACION DE CONFORMIDAD • ERKLÄRUNG BEZÜGLICH EINHALTUNG DER VORSCHRIFTENDICHIARAZIONE DI CONFORMITÀ • CONFORMITEITSVERKLARING • DEKLARATION OM ÖVERENSSTÄMMELSE
EF-OVERENSSTEMMELSESERKLÆRING • VAATIMUSTENMUKAISUUSVAKUUTUS • SAMSVARSERKLÄRING DECLARAÇAO DE CONFORMIDADE
VERSA-MATIC®
Warren Rupp, Inc.A Unit of IDEX Corporation 800 North Main Street P.O. Box 1568 Mansfield, OH 44901-1568 USA
Tel: 419-526-7296Fax: 419-526-7289
This product has used the following harmonized standards to verify conformance: EN809:1998+A1:2009Ce materiel est fabriqué selon les normes harmonisées suivantes, afin d’ en garantir la conformité:
Este producto cumple con las siquientes directrices de la comunidad europa:Dieses produkt ist nach folgenden harmonisierten standards gefertigtworden, die übereinstimmung wird bestätigt:Questo prodotto ha utilizzato i seguenti standards per verificare la conformita´:De volgende geharmoniseerde normen werden gehanteerd om de conformiteit van dit produkt te garanderen: För denna produkt har följande harmoniserande standarder använts för att bekräfta överensstämmelse:Harmoniserede standarder, der er benyttet:Tässä tuotteessa on sovellettu seuraavia yhdenmukaistettuja standardeja:Dette produkt er produsert i overenstemmelse med fløgende harmoniserte standarder:Este produto utilizou os seguintes padrões harmonizados para varificar conformidade:
PUMP MODEL SERIES: E SERIES, V SERIES, VT SERIES, VSMA3, SPA15, RE SERIES AND U2 SERIES
Dave RoseberryEngineering Manager
DECLARATION OF CONFORMITY
2006/42/ECon Machinery, according
to Annex VIII
MODEL SPECIFIC
Repair Kit
vs.
Partial Repair
=
• Reduces frequency of repairs• Reduces downtime• Reduces cost• Increase your uptime • Improve parts availability• Extended service life
Ordering Parts Kits Over Individual Components:
Example Data:Repair = 1 hour • Pump model #: E2AA2D220-OE • Buna wet-end repairLabor rate fully burdened at $125/hour • Lost product assumes paint
COST OF WET END REPAIR Partial Repair
(1 Diaphragm)Complete Repair
KitParts $56 $148
Labor $125 $125
Lost Product $200 $200
Down-Time $1,000 $1,000
Annual Frequency of Repair 2 1Estimated Cost Per Repair:
$1,381 $1,473
Estimated Annual Cost:
$2,772 $1,473
EstimatedAnnual Savings:* $0 $1,299
www.versamatic.com
Kit: AnnualSavings
$1,299
Genuine Parts, Real Value