1.2 BETTER APARTMENT DESIGN STANDARDS
Transcript of 1.2 BETTER APARTMENT DESIGN STANDARDS
CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS — 19ARM ARCHITECTURE
1.2 BETTER APARTMENT DESIGN STANDARDS
GROUND LEVEL_DESIGN GUIDELEINES - 1:250 @ A1/AUGUST 2019/TP-A1602
SITE LEVEL 01_DESIGN GUIDELEINES - 1:250 @ A1/AUGUST 2019/TP-A1603 SITE LEVEL 02_DESIGN GUIDELEINES - 1:250 @ A1/AUGUST 2019/TP-A1604
SITE LEVEL 03_DESIGN GUIDELEINES - 1:250 @ A1/AUGUST 2019/TP-A1605
SITE LEVEL 04_DESIGN GUIDELEINES - 1:250 @ A1/AUGUST 2019/TP-A1606 SITE LEVEL 05_DESIGN GUIDELEINES - 1:250 @ A1/AUGUST 2019/TP-A1607
SITE LEVEL 06_DESIGN GUIDELEINES - 1:250 @ A1/AUGUST 2019/TP-A1608
SITE LEVEL 07_DESIGN GUIDELEINES - 1:250 @ A1/AUGUST 2019/TP-A1609
SITE LEVEL 08_DESIGN GUIDELEINES - 1:250 @ A1/AUGUST 2019/TP-A1610
SITE LEVEL 09_DESIGN GUIDELEINES - 1:250 @ A1/AUGUST 2019/TP-A1611
20 — CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS ARM ARCHITECTURE
SITE LEVEL 07 PLAN1:250 @A1/AUGUST 2019/TP-A1109
0m 5m 15m 30m 50m
####
####
77.4 m²
C2-CHG.APT.03
72.9 m²
C2-A
HG.APT.0254.3 m²
B5-B
HG.APT.0173.2 m²
C2-AHG.APT.0577.2 m²
C2-C
HG.APT.04 76.8 m²
C2-C
MG.APT.0573.2 m²
C2-AMG.APT.06
78.1 m²
LOBBY
MG.LOB.01
STAIRLIFT
BIN
54.5 m²
B5-AMG.APT.01
73.3 m²
C2-AMG.APT.02
73.6 m²
C2-A
MG.APT.03 76.6 m²
C2-CMG.APT.04
71.1 m²
C2-BFG.APT.02
72.5 m²
C2-B
FG.APT.01
LIFTS
STAIR
20.8 m²BALC
22.7 m²BALC
30.6 m²BALC 21.0 m²
BALC 22.7 m²BALC
22.4 m²BALC
20.9 m²BALC
29.9 m²BALC
20.7 m²BALC
20.9 m²BALC
22.3 m²BALC
11.6 m²BALC
11.5 m²BALC
12.2 m²BALC
73.0 m²
C2-B
FG.APT.032940
3060
2010
2010
1910
2010
2010
2010
MAILROOM
PARCEL PICK UP ROOM
SERVICESSERVICES
SERVICES
1560
2000
BIN
RETAIL LIFT
SERVICES
15602000
15602000 SERVICES
SERV
ICES
RES
I CO
RR
IDO
R
MAIL BOXES MAIL BOXES53
20
8790 8410 9210 8440 8730 8930 8440
5240
9170 8440 8440 8820
MAIL BOXES
MAIL BOXES
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 11:06:25 AM
C:\Users\rli\Documents\1187_AR_SITE MASTERPLAN_rli.rvt
18
02/08/20191:250
TP-A1602Ground Level_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1602 [18]- Ground Level_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/201914 TP REVISION 14 19/07/201915 TP REVISION 15 23/07/201917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
####
####
77.4 m²
C2-CHG.APT.03
72.9 m²
C2-A
HG.APT.0252.8 m²
B5-B
HG.APT.0173.9 m²
C2-AHG.APT.0577.6 m²
C2-C
HG.APT.04 77.5 m²
C2-C
MG.APT.0573.5 m²
C2-AMG.APT.06
79.4 m²
LOBBY
MG.LOB.01
STAIRLIFT BIN
53.8 m²
B5-AMG.APT.01
73.4 m²
C2-AMG.APT.02
72.7 m²
C2-A
MG.APT.03 76.7 m²
C2-CMG.APT.04
71.1 m²
C2-BFG.APT.02
72.5 m²
C2-B
FG.APT.01
LIFTS
STAIR
20.4 m²BALC
22.4 m²BALC
30.1 m²BALC 21.1 m²
BALC 22.7 m²BALC 22.5 m²
BALC21.3 m²BALC
29.7 m²BALC
20.6 m²BALC
21.2 m²BALC
22.7 m²BALC
11.6 m²BALC
11.5 m²BALC
12.2 m²BALC
73.0 m²
C2-B
FG.APT.03
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOMTYPE A - MINIMUM 1200mm X 1200MM ORTYPE B - MINIMUM 1000mm X 2700MM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
A or B
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 15, 28 Freshwater PlaceSouthbank, VIC 3006 Australia
Phone: +61 3 8327 8600Fax: +61 3 8327 8699
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
12/07/2019 9:22:52 AM
C:\Revit Local\1187_AR_SITE MASTERPLAN_lbailey.rvt
9
21/06/20191:250
TP-A1602Ground Level_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1602 [9]- Ground Level_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/2019
CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS — 21ARM ARCHITECTURE
SITE LEVEL 08 PLAN1:250 @A1/AUGUST 2019/TP-A1110
0m 5m 15m 30m 50m
223 m²
PLANT-SUPERMARKETMEZL1.BH.01
77.2 m²
C2-C
H1.APT.05
8.6 m²BALC
8.1 m²BALC
73.2 m²
C2-AH1.APT.06
54.8 m²
B5-C
H1.APT.07
16.6 m²BALC
53.6 m²
B5-BH1.APT.01
16.6 m²BALC
72.9 m²
C2-AH1.APT.02
8.1 m²BALC
77.4 m²
C2-C
H1.APT.03
8.6 m²BALC
79.3 m²
C2-CH1.APT.04
9.2 m²BALC
73.0 m²
C2-B
F1.APT.03
11.6 m²BALC
11.5 m²BALC
71.1 m²
C2-B
F1.APT.02
72.5 m²
C2-BF1.APT.01
12.1 m²BALC
8.6 m²BALC
8.1 m²BALC
76.8 m²
C2-CM1.APT.05
73.2 m²
C2-AM1.APT.06 55.1 m²
B5-CM1.APT.07
54.1 m²
B5-AM1.APT.01
73.3 m²
C2-A
M1.APT.0273.6 m²
C2-A
M1.APT.03
8.2 m²BALC
8.4 m²BALC
76.6 m²
C2-CM1.APT.04
LIFT STAIR
16.7 m²BALC
19.5 m²BALC
STAIR
LIFT
LIFT STAIR
BINBIN
LIFT
65.9 m²
B3-F
G1.APT.01
90.4 m²
D2-AG1.APT.02
75.4 m²
C2-AG1.APT.03
72.2 m²
C2-B
G1.APT.04
54.6 m²
B3-D
G1.APT.05BIN
STAIR
LIFT
17.2 m²BALC
14.6 m²BALC
10.2 m²BALC
9.7 m²BALC
9.6 m²BALC
FFL. 51.500CH. TO U/S: 3550
8.0 m²BALC
VOID
2940
2320
2010
1910
2010
1910
2010
2140
3060
1910
2010
1910
2010
2140
2140
2550
2550
SERVICES
SERVICES
SERVICES
1560
2000
SERVICES 15602000
SERVICES 15602000 SERVICESSERVICES
1560
2000
SERV
ICES
BIN
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 11:06:41 AM
C:\Users\rli\Documents\1187_AR_SITE MASTERPLAN_rli.rvt
18
02/08/20191:250
TP-A1603Site Level 1_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1603 [18]- Site Level 1_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/201914 TP REVISION 14 19/07/201915 TP REVISION 15 23/07/201917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
####
####
77.4 m²
C2-CHG.APT.03
72.9 m²
C2-A
HG.APT.0252.8 m²
B5-B
HG.APT.0173.9 m²
C2-AHG.APT.0577.6 m²
C2-C
HG.APT.04 77.5 m²
C2-C
MG.APT.0573.5 m²
C2-AMG.APT.06
79.4 m²
LOBBY
MG.LOB.01
STAIRLIFT BIN
53.8 m²
B5-AMG.APT.01
73.4 m²
C2-AMG.APT.02
72.7 m²
C2-A
MG.APT.03 76.7 m²
C2-CMG.APT.04
71.1 m²
C2-BFG.APT.02
72.5 m²
C2-B
FG.APT.01
LIFTS
STAIR
20.4 m²BALC
22.4 m²BALC
30.1 m²BALC 21.1 m²
BALC 22.7 m²BALC 22.5 m²
BALC21.3 m²BALC
29.7 m²BALC
20.6 m²BALC
21.2 m²BALC
22.7 m²BALC
11.6 m²BALC
11.5 m²BALC
12.2 m²BALC
73.0 m²
C2-B
FG.APT.03
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOMTYPE A - MINIMUM 1200mm X 1200MM ORTYPE B - MINIMUM 1000mm X 2700MM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
A or B
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 15, 28 Freshwater PlaceSouthbank, VIC 3006 Australia
Phone: +61 3 8327 8600Fax: +61 3 8327 8699
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
12/07/2019 9:22:52 AM
C:\Revit Local\1187_AR_SITE MASTERPLAN_lbailey.rvt
9
21/06/20191:250
TP-A1602Ground Level_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1602 [9]- Ground Level_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/2019
22 — CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS ARM ARCHITECTURE
SITE LEVEL 07 PLAN1:250 @A1/AUGUST 2019/TP-A1109
0m 5m 15m 30m 50m
UP
73.1 m²
C3-A
H2.APT.04
41.9 m²BALC
73.7 m²
C3-AM2.APT.04
76.7 m²
C4-BM2.APT.05
76.2 m²
C4-BH2.APT.05
46.7 m²BALC
75.0 m²
C4-A
H2.APT.01
46.7 m²BALC
73.1 m²
C3-AH2.APT.02
42.1 m²BALC
79.3 m²
C2-CH2.APT.03
9.2 m²BALC
72.9 m²
C2-B
F2.APT.06
11.6 m²BALC
71.2 m²
C2-B
F2.APT.05
11.6 m²BALC
71.2 m²
C2-B
F2.APT.04
11.6 m²BALC
73.0 m²
C2-A
F2.APT.03
11.6 m²BALC
72.8 m²
C2-A
F2.APT.02
11.6 m²BALC
11.5 m²BALC
76.3 m²
C2-AF2.APT.01
75.0 m²
C4-AM2.APT.01
70.9 m²
C3-C
M2.APT.0251.7 m²
B2-A
M2.APT.03
42.3 m²BALC
46.1 m²BALC
53.3 m²BALC
38.6 m²BALC
BIN
LIFT STAIRLIFTSTAIR
BIN
STAIR
LIFT
65.9 m²
B3-F
G2.APT.01
90.4 m²
D2-AG2.APT.02
75.4 m²
C2-A
G2.APT.03
72.2 m²
C2-BG2.APT.04
9.2 m²BALC
8.7 m²BALC
8.6 m²BALC
12.9 m²BALC
15.6 m²BALC
54.6 m²
B3-DG2.APT.05BIN
STAIR
LIFT
57.5 m²
B1-AE1.APT.01
53.3 m²
B1-AE1.APT.02
52.8 m²
B1-AE1.APT.03
52.2 m²
B1-AE1.APT.04
52.2 m²
B1-AE1.APT.05
53.1 m²
B1-AE1.APT.06
54.0 m²
B1-AE1.APT.07
52.8 m²
B3-A
L1.APT.0140.8 m²
A2-BL1.APT.02
50.3 m²
B7-BL1.APT.03
38.8 m²
A1-AL1.APT.04
38.4 m²
A1-AL1.APT.05
38.4 m²
A1-AL1.APT.06
52.8 m²
B1-AL1.APT.07
52.8 m²
B1-AL1.APT.08
52.8 m²
B1-AL1.APT.09
54.8 m²
B1-AL1.APT.10
47.3 m²
A2-E
L1.APT.1173.2 m²
C2-B
L1.APT.1252.5 m²
B3-A
L1.APT.13
9.5 m²BALC
8.5 m²BALC
8.3 m²BALC
8.3 m²BALC
8.3 m²BALC
8.7 m²BALC
8.7 m²BALC
BIN
CORRIDOR
LIFT
STAIR
10.6 m²BALC
14.9 m²BALC
19.2 m²BALC
9.0 m²BALC
8.3 m²BALC
9.1 m²BALC
8.8 m²BALC
8.8 m²BALC9.7 m²
BALC
15.9 m²BALC
10.8 m²BALC
10.7 m²BALC
LIFT
STAIR
BINPLANT
CORRIDOR
RISER
VOID
FFL. 51.100
2140
2140
2140
8.3 m²BALC
2070
2110
2400
1860
2000
32.1 m²BALC
2290
2920
3040
2120
2030
2130
2750
2800
2750
2800
2800
2750
2010
2120
2070
2620
2230
2230
2430
2430
2480
2520
2300
SERVICES
1580
2020
SERVICES 15602000
SERVICES SERVICESSERVICES 2000
1560
SERVICES SERVICES SERVICES2000
1532
SERVICES SERVICES2000
1560
1560
2000
SERVICES
SERVICES
SERV
ICES
2750
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 11:07:00 AM
C:\Users\rli\Documents\1187_AR_SITE MASTERPLAN_rli.rvt
18
02/08/20191:250
TP-A1604Site Level 2_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1604 [18]- Site Level 2_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/201914 TP REVISION 14 19/07/201915 TP REVISION 15 23/07/201917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
####
####
77.4 m²
C2-CHG.APT.03
72.9 m²
C2-A
HG.APT.0252.8 m²
B5-B
HG.APT.0173.9 m²
C2-AHG.APT.0577.6 m²
C2-C
HG.APT.04 77.5 m²
C2-C
MG.APT.0573.5 m²
C2-AMG.APT.06
79.4 m²
LOBBY
MG.LOB.01
STAIRLIFT BIN
53.8 m²
B5-AMG.APT.01
73.4 m²
C2-AMG.APT.02
72.7 m²
C2-A
MG.APT.03 76.7 m²
C2-CMG.APT.04
71.1 m²
C2-BFG.APT.02
72.5 m²
C2-B
FG.APT.01
LIFTS
STAIR
20.4 m²BALC
22.4 m²BALC
30.1 m²BALC 21.1 m²
BALC 22.7 m²BALC 22.5 m²
BALC21.3 m²BALC
29.7 m²BALC
20.6 m²BALC
21.2 m²BALC
22.7 m²BALC
11.6 m²BALC
11.5 m²BALC
12.2 m²BALC
73.0 m²
C2-B
FG.APT.03
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOMTYPE A - MINIMUM 1200mm X 1200MM ORTYPE B - MINIMUM 1000mm X 2700MM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
A or B
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 15, 28 Freshwater PlaceSouthbank, VIC 3006 Australia
Phone: +61 3 8327 8600Fax: +61 3 8327 8699
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
12/07/2019 9:22:52 AM
C:\Revit Local\1187_AR_SITE MASTERPLAN_lbailey.rvt
9
21/06/20191:250
TP-A1602Ground Level_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1602 [9]- Ground Level_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/2019
CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS — 23ARM ARCHITECTURE
SITE LEVEL 08 PLAN1:250 @A1/AUGUST 2019/TP-A1110
0m 5m 15m 30m 50m
UP
62.0 m²
YOGAL3.RT.05
155 m²
GYML3.CH.04
155 m²
DININGL3.CH.07
7.0 m²
BABY CHANGECH.AM.06
10.6 m²
DDACH.AM.07
69.2 m²
THEATREL3.RT.03
70.0 m²
GAMESL3.RT.02
57.2 m²
GOLF SIML3.RT.01
183 m²
THE HEARTHL3.CH.01
10.8 m²
SPAL3.PO.01
103.0 m²
POOLL3.PO.02
146 m²
POOLLOUNGEL3.CH.03
22.0 m²
FEMALE CHANGECH.AM.08
24.2 m²
MALE CHANGECH.AM.09
9.7 m²
CLEANER/BINL3.BH.05
19.7 m²
STUDY 1L3.ST.01
28.2 m²
MECH PLANTL3.BH.01
6.9 m²
DDACH.AM.0529.9 m²
FEMALE WCCH.AM.03
26.6 m²
MALE WCCH.AM.02
2050 m²
OUTDOORL3.OD.01
73.1 m²
C3-AH3.APT.04
9.3 m²BALC
76.2 m²
C4-BH3.APT.05
8.1 m²BALC
75.0 m²
C4-AH3.APT.01
8.1 m²BALC
73.1 m²
C3-AH3.APT.02
9.3 m²BALC
79.3 m²
C2-CH3.APT.039.2 m²
BALC
73.0 m²
C2-BF3.APT.04
8.1 m²BALC
8.1 m²BALC
71.2 m²
C2-BF3.APT.05
71.1 m²
C2-BF3.APT.06
8.1 m²BALC
8.1 m²BALC
72.9 m²
C2-AF3.APT.07
73.0 m²
C2-AF3.APT.08
8.1 m²BALC
8.1 m²BALC
76.1 m²
C2-AF3.APT.09
76.2 m²
C2-AF3.APT.03
8.5 m²BALC
75.0 m²
C2-AF3.APT.02
9.6 m²BALC
10.7 m²BALC
56.3 m²
B3-EF3.APT.01
9.6 m²BALC
40.1 m²
A4-AK3.APT.08
28.5 m²
BINKG.BH.09
22.2 m²
CORRIDORK3.BH.11
CORRIDOR
40.0 m²
A2-DK3.APT.02
40.8 m²
A2-DK3.APT.03
54.1 m²
B7-AK3.APT.04
40.0 m²
A2-DK3.APT.01
9.6 m²BALC
9.4 m²BALC
9.2 m²BALC
10.1 m²BALC
10.5 m²BALC
STAIR
LIFT
BIN
LIFTSTAIR
BIN
STAIR
LIFT
65.9 m²
B3-FG3.APT.01
90.4 m²
D2-AG3.APT.02
53.2 m²
B1-EG3.APT.03
51.0 m²
B1-EG3.APT.04
51.0 m²
B1-EG3.APT.05
50.7 m²
B1-EG3.APT.06
51.0 m²
B1-EG3.APT.07
51.0 m²
B1-EG3.APT.08
53.8 m²
B1-EG3.APT.09
75.4 m²
C2-AG3.APT.10
72.2 m²
C2-BG3.APT.11
54.6 m²
B3-DG3.APT.12
BIN
STAIR
LIFT
SERVICE
8.7 m²BALC
8.6 m²BALC
12.9 m²BALC
15.6 m²BALC
9.7 m²BALC
9.6 m²BALC
9.9 m²BALC
9.7 m²BALC
9.6 m²BALC
9.7 m²BALC
9.2 m²BALC
10.7 m²BALC
40.2 m²
A2-BJ3.APT.01
40.8 m²
A2-BJ3.APT.02
41.9 m²
A2-BJ3.APT.03
41.5 m²
A2-BJ3.APT.04
40.4 m²
A2-BJ3.APT.05
40.4 m²
A2-BJ3.APT.06
40.4 m²
A2-BJ3.APT.07
9.6 m²BALC
9.4 m²BALC
9.6 m²BALC
STAIR
9.5 m²BALC
9.3 m²BALC
9.5 m²BALC
9.3 m²BALC
10.1 m²BALC
LIFT
CO
RR
IDO
R
CO
RR
IDO
R
40.4 m²
A4-AJ3.APT.08
54.7 m²
B3-AE2.APT.01
74.1 m²
C2-BE2.APT.02
57.5 m²
B1-AE2.APT.03
53.3 m²
B1-AE2.APT.04
52.8 m²
B1-AE2.APT.05
52.2 m²
B1-AE2.APT.06
52.2 m²
B1-AE2.APT.07
53.1 m²
B1-AE2.APT.08
54.0 m²
B1-AE2.APT.09
58.7 m²
B7-AE2.APT.10
40.4 m²
A2-BE2.APT.11
40.4 m²
A2-BE2.APT.12
40.0 m²
A2-FE2.APT.13
40.0 m²
A2-FE2.APT.14
47.2 m²
B3-BE2.APT.15
11.5 m²BALC
10.2 m²BALC
9.5 m²BALC
8.5 m²BALC
8.3 m²BALC
8.3 m²BALC
8.3 m²BALC
8.7 m²BALC8.7 m²
BALC
16.3 m²BALC
14.0 m²BALC
10.2 m²BALC
13.0 m²BALC
13.0 m²BALC
10.9 m²BALC
LIFT
STAIR
CORRIDOR
BIN
RISER
8.8 m²BALC
12.3 m²BALC
15.9 m²BALC
9.0 m²BALC
8.3 m²BALC
8.3 m²BALC
9.1 m²BALC
8.8 m²BALC
8.8 m²BALC
9.7 m²BALC
13.4 m²BALC
9.0 m²BALC
8.9 m²BALC
BINPLANT
CORRIDOR
LIFT
STAIR
RISER
52.8 m²
B3-AL2.APT.01
40.8 m²
A2-BL2.APT.02 50.3 m²
B7-BL2.APT.03
38.8 m²
A1-AL2.APT.04
38.4 m²
A1-AL2.APT.05
38.4 m²
A1-AL2.APT.0652.8 m²
B1-AL2.APT.07
52.8 m²
B1-AL2.APT.08
52.8 m²
B1-AL2.APT.09
54.8 m²
B1-AL2.APT.10
47.3 m²
A2-EL2.APT.11 73.2 m²
C2-BL2.APT.12 52.5 m²
B3-AL2.APT.13
13.5 m²
SAUNACH.AM.00
17.3 m²
KIDS PLAYL3.KP.01
21.8 m²
BINJ3.BH.01
9.6 m²BALC
9.6 m²BALC
8.4 m²BALC
40.8 m²
A2-DK3.APT.07
40.8 m²
A2-DK3.APT.06
42.5 m²
A2-DK3.APT.05
19.7 m²
STUDY 2L3.ST.02
138 m²
WORKBENCHL3.CH.02
BOH
115.7 m²
CORRIDORL3.PC.01
BIN
FFL. 55.700
FFL. 55.700
FFL. 55.000
110.6 m²
CORRIDORJ3.PC.01
RESI & RETAIL RISER
1780
2700
FFL. 54.150
22.5 m²BALC
74.9 m²
C2-BF3.APT.10
81.1 m²
C5-BF3.APT.11
2760
2670
2240
2240
2230
2140
2230
2010
2000
1860
2010
1970
1970
1970
2240
2100 27
30
3050
2140
2140
3040
2290
2010
2010
2020
2010
2010
1810
1780
1810
2140
2720
2230
2400
2430
2430
22202520
2120
2120
212024
30
197026
00
2070
2110
2240
SERVICES
1560
2000
SERVICES 15602000
SERVICES
SERVICES SERVICES SERVICES2000
1560
SERVICES SERVICES2000
1560
1560
2000
SERVICES
SERVICES
SERV
ICES
SERV
ICES
SERV
ICES
SERVICES
1560
20041560
2000
2010
ROOF OUTLINEROOF OUTLINE
PERGOLA OVERHANG
CANOPY ABOVE
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000
Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 4:59:29 PM
C:\Users\rli\Documents\1187_AR_SITE MASTERPLAN_rli.rvt
18
02/08/20191:250
TP‐A1605Site Level 3_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP‐A1605 [18]‐ Site Level 3_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/201914 TP REVISION 14 19/07/201915 TP REVISION 15 23/07/201917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
####
####
77.4 m²
C2-CHG.APT.03
72.9 m²
C2-A
HG.APT.0252.8 m²
B5-B
HG.APT.0173.9 m²
C2-AHG.APT.0577.6 m²
C2-C
HG.APT.04 77.5 m²
C2-C
MG.APT.0573.5 m²
C2-AMG.APT.06
79.4 m²
LOBBY
MG.LOB.01
STAIRLIFT BIN
53.8 m²
B5-AMG.APT.01
73.4 m²
C2-AMG.APT.02
72.7 m²
C2-A
MG.APT.03 76.7 m²
C2-CMG.APT.04
71.1 m²
C2-BFG.APT.02
72.5 m²
C2-B
FG.APT.01
LIFTS
STAIR
20.4 m²BALC
22.4 m²BALC
30.1 m²BALC 21.1 m²
BALC 22.7 m²BALC 22.5 m²
BALC21.3 m²BALC
29.7 m²BALC
20.6 m²BALC
21.2 m²BALC
22.7 m²BALC
11.6 m²BALC
11.5 m²BALC
12.2 m²BALC
73.0 m²
C2-B
FG.APT.03
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOMTYPE A - MINIMUM 1200mm X 1200MM ORTYPE B - MINIMUM 1000mm X 2700MM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
A or B
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 15, 28 Freshwater PlaceSouthbank, VIC 3006 Australia
Phone: +61 3 8327 8600Fax: +61 3 8327 8699
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
12/07/2019 9:22:52 AM
C:\Revit Local\1187_AR_SITE MASTERPLAN_lbailey.rvt
9
21/06/20191:250
TP-A1602Ground Level_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1602 [9]- Ground Level_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/2019
24 — CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS ARM ARCHITECTURE
SITE LEVEL 07 PLAN1:250 @A1/ AUGUST 2019/TP-A1109
0m 5m 15m 30m 50m
56.3 m²
B3-EF4.APT.01
8.2 m²BALC
9.1 m²BALC
75.0 m²
C2-A
F4.APT.02
76.2 m²
C2-AF4.APT.03
8.6 m²BALC
73.0 m²
C2-BF4.APT.04
8.1 m²BALC
8.1 m²BALC
71.2 m²
C2-BF4.APT.05
71.2 m²
C2-BF4.APT.06
8.1 m²BALC
8.1 m²BALC
72.9 m²
C2-AF4.APT.07
73.0 m²
C2-A
F4.APT.08
76.1 m²
C2-AF4.APT.09
75.0 m²
C2-B
F4.APT.10
19.1 m²BALC
STAIR
BIN
LIFT
8.1 m²BALC
8.1 m²BALC
65.9 m²
B3-FG4.APT.01
90.4 m²
D2-AG4.APT.02
53.2 m²
B1-EG4.APT.03
51.0 m²
B1-E
G4.APT.04
51.0 m²
B1-EG4.APT.05
50.7 m²
B1-E
G4.APT.06
51.0 m²
B1-EG4.APT.07
51.0 m²
B1-EG4.APT.08
53.8 m²
B1-E
G4.APT.0975.4 m²
C2-A
G4.APT.10
72.2 m²
C2-B
G4.APT.11
54.6 m²
B3-DG4.APT.12
BIN
STAIR
LIFT
9.2 m²BALC
8.7 m²BALC
8.6 m²BALC
12.9 m²BALC
15.6 m²BALC
10.7 m²BALC
9.7 m²BALC
9.6 m²BALC
9.9 m²BALC
9.7 m²BALC
9.6 m²BALC
9.7 m²BALC
40.0 m²
A2-D
K4.APT.02
40.8 m²
A2-D
K4.APT.03
54.2 m²
B7-AK4.APT.04
40.1 m²
A2-DK4.APT.01
54.2 m²
B1-AK4.APT.05
53.0 m²
B1-A
K4.APT.06
49.2 m²
B1-D
K4.APT.07
53.0 m²
B1-A
K4.APT.08
50.9 m²
B1-BK4.APT.09
50.9 m²
B1-BK4.APT.10
54.4 m²
B1-FK4.APT.11
42.4 m²
A2-DK4.APT.12
40.8 m²
A2-DK4.APT.13
40.8 m²
A2-D
K4.APT.14
40.0 m²
A4-AK4.APT.15
10.4 m²BALC
10.3 m²BALC
10.5 m²BALC
11.5 m²BALC
10.2 m²BALC
10.2 m²BALC
10.2 m²BALC
10.2 m²BALC
10.2 m²BALC
10.2 m²BALC
10.3 m²BALC
9.7 m²BALC
10.5 m²BALC
10.5 m²BALC
11.0 m²BALC
BIN
STAIR
LIFT
CORRIDOR
40.3 m²
A2-BJ4.APT.01
40.8 m²
A2-BJ4.APT.02
41.9 m²
A2-B
J4.APT.03
52.0 m²
B1-B
J4.APT.04
49.9 m²
B1-B
J4.APT.05
49.8 m²
B1-BJ4.APT.06
47.5 m²
B1-D
J4.APT.07
51.7 m²
B1-A
J4.APT.08
51.9 m²
B1-AJ4.APT.09
54.6 m²
B1-A
J4.APT.10 41.5 m²
A2-BJ4.APT.11
40.4 m²
A2-BJ4.APT.12
40.4 m²
A2-BJ4.APT.13
40.4 m²
A4-AJ4.APT.15
10.4 m²BALC
10.1 m²BALC
10.3 m²BALC
10.0 m²BALC
10.0 m²BALC
10.0 m²BALC
10.0 m²BALC
10.0 m²BALC
10.1 m²BALC
11.1 m²BALC
10.0 m²BALC
10.0 m²BALC
10.5 m²BALC
10.2 m²BALC
10.5 m²BALC
STAIR
LIFT
BIN
CO
RR
IDO
R
CO
RR
IDO
R
CO
RR
IDO
R
54.7 m²
B3-A
E3.APT.0174.1 m²
C2-B
E3.APT.02
57.5 m²
B1-A
E3.APT.0353.3 m²
B1-AE3.APT.04
52.8 m²
B1-AE3.APT.0552.2 m²
B1-A
E3.APT.0652.2 m²
B1-A
E3.APT.0753.1 m²
B1-A
E3.APT.0854.0 m²
B1-AE3.APT.09
58.7 m²
B7-AE3.APT.10
40.4 m²
A2-BE3.APT.11
40.4 m²
A2-BE3.APT.12
40.0 m²
A2-FE3.APT.13
40.0 m²
A2-FE3.APT.14
47.2 m²
B3-BE3.APT.15
9.5 m²BALC
8.4 m²BALC
9.5 m²BALC
8.5 m²BALC
8.3 m²BALC
8.3 m²BALC8.3 m²
BALC8.7 m²BALC8.7 m²
BALC
16.3 m²BALC
11.5 m²BALC
8.4 m²BALC
10.7 m²BALC
10.7 m²BALC
9.0 m²BALC
BINPLANT
CORRIDOR
STAIR
LIFT
RISER
8.8 m²BALC
12.3 m²BALC
15.9 m²BALC
9.0 m²BALC
8.3 m²BALC
8.3 m²BALC
9.1 m²BALC
8.8 m²BALC
8.8 m²BALC
9.7 m²BALC
13.4 m²BALC
9.0 m²BALC
8.9 m²BALC
LIFT
STAIR
RISER
CORRIDOR
PLANTBIN
52.8 m²
B3-AL3.APT.01
40.8 m²
A2-BL3.APT.02
50.3 m²
B7-BL3.APT.03
38.8 m²
A1-A
L3.APT.0438.4 m²
A1-AL3.APT.05
38.4 m²
A1-AL3.APT.06
52.8 m²
B1-AL3.APT.07
52.8 m²
B1-AL3.APT.08
52.8 m²
B1-A
L3.APT.0954.8 m²
B1-AL3.APT.10
47.3 m²
A2-EL3.APT.11
73.2 m²
C2-BL3.APT.12
52.5 m²
B3-AL3.APT.13
SERVICESERVICE
2430
2030
2030
2130
1970
10588
8345
8.1 m²BALC
40.4 m²
A2-BJ4.APT.14
81.0 m²
C5-BF4.APT.11
2700
2700
2700
2240
2230
2140
2230
2870
2870
2870
2870
1900
9070
11594
2070
1860
2000
2030
1970
1970
2140
2010 2010
2010
1910
2010
2080
1900
1900
1900
1900
11520
2870
2670
2010
2010
2670
2670
2670
2670
2240
2240
1350
1350
1900
1350
1350
2110
1970
2520
2430
2430
2400
2070
2110
2720
SERVICES
1560
2000
SERVICES SERVICES SERVICES2000
1560
SERVICES SERVICES2000
1560
1560
2000
SERVICES
SERVICES
SERV
ICES
SERV
ICES
SERV
ICES
SERVICES
1560
20001532
2000
1900
1204
0
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 11:07:41 AM
C:\Users\rli\Documents\1187_AR_SITE MASTERPLAN_rli.rvt
18
02/08/20191:250
TP-A1606Site Level 4_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 RLDW
TP-A1606 [18]- Site Level 4_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/201914 TP REVISION 14 19/07/201915 TP REVISION 15 23/07/201917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
####
####
77.4 m²
C2-CHG.APT.03
72.9 m²
C2-A
HG.APT.0252.8 m²
B5-B
HG.APT.0173.9 m²
C2-AHG.APT.0577.6 m²
C2-C
HG.APT.04 77.5 m²
C2-C
MG.APT.0573.5 m²
C2-AMG.APT.06
79.4 m²
LOBBY
MG.LOB.01
STAIRLIFT BIN
53.8 m²
B5-AMG.APT.01
73.4 m²
C2-AMG.APT.02
72.7 m²
C2-A
MG.APT.03 76.7 m²
C2-CMG.APT.04
71.1 m²
C2-BFG.APT.02
72.5 m²
C2-B
FG.APT.01
LIFTS
STAIR
20.4 m²BALC
22.4 m²BALC
30.1 m²BALC 21.1 m²
BALC 22.7 m²BALC 22.5 m²
BALC21.3 m²BALC
29.7 m²BALC
20.6 m²BALC
21.2 m²BALC
22.7 m²BALC
11.6 m²BALC
11.5 m²BALC
12.2 m²BALC
73.0 m²
C2-B
FG.APT.03
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOMTYPE A - MINIMUM 1200mm X 1200MM ORTYPE B - MINIMUM 1000mm X 2700MM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
A or B
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 15, 28 Freshwater PlaceSouthbank, VIC 3006 Australia
Phone: +61 3 8327 8600Fax: +61 3 8327 8699
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
12/07/2019 9:22:52 AM
C:\Revit Local\1187_AR_SITE MASTERPLAN_lbailey.rvt
9
21/06/20191:250
TP-A1602Ground Level_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1602 [9]- Ground Level_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/2019
CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS — 25ARM ARCHITECTURE
SITE LEVEL 08 PLAN1:250 @A1/AUGUST 2019/TP-A1110
0m 5m 15m 30m 50m
56.3 m²
B3-E
F5.APT.01
BIN
STAIR
LIFT
90.7 m²
C5-A
F5.APT.11
75.1 m²
C2-B
F5.APT.10
75.0 m²
C2-A
F5.APT.02
8.2 m²BALC
9.1 m²BALC
76.2 m²
C2-A
F5.APT.038.6 m²BALC
73.0 m²
C2-BF5.APT.04
8.1 m²BALC
71.2 m²
C2-B
F5.APT.058.1 m²BALC
71.2 m²
C2-B
F5.APT.06
72.9 m²
C2-AF5.APT.07
8.1 m²BALC
8.1 m²BALC
73.0 m²
C2-AF5.APT.08
19.1 m²BALC
8.1 m²BALC
8.1 m²BALC
76.1 m²
C2-A
F5.APT.09
65.9 m²
B3-F
G5.APT.01
90.4 m²
D2-A
G5.APT.02
53.2 m²
B1-E
G5.APT.03
51.0 m²
B1-EG5.APT.04
51.0 m²
B1-E
G5.APT.05
50.7 m²
B1-EG5.APT.06
51.0 m²
B1-E
G5.APT.07
51.0 m²
B1-E
G5.APT.08
53.8 m²
B1-E
G5.APT.0975.4 m²
C2-A
G5.APT.10
72.2 m²
C2-B
G5.APT.11
54.6 m²
B3-DG5.APT.12
BIN
STAIR
LIFT
9.2 m²BALC
9.7 m²BALC
9.6 m²BALC
8.7 m²BALC
9.7 m²BALC
9.9 m²BALC
8.6 m²BALC
12.9 m²BALC
15.6 m²BALC
9.6 m²BALC
9.7 m²BALC
10.7 m²BALC
40.1 m²
A2-D
K5.APT.01
40.0 m²
A2-DK5.APT.02
40.8 m²
A2-D
K5.APT.03
54.2 m²
B7-AK5.APT.04 54.2 m²
B1-A
K5.APT.05
53.0 m²
B1-A
K5.APT.06
49.2 m²
B1-DK5.APT.07
53.0 m²
B1-AK5.APT.08
50.9 m²
B1-BK5.APT.09
50.9 m²
B1-BK5.APT.10
54.4 m²
B1-F
K5.APT.1142.4 m²
A2-DK5.APT.12
40.8 m²
A2-DK5.APT.13
40.8 m²
A2-DK5.APT.14
40.0 m²
A4-AK5.APT.15
10.4 m²BALC
10.3 m²BALC
10.5 m²BALC
11.5 m²BALC
8.8 m²BALC
8.8 m²BALC
8.8 m²BALC
8.7 m²BALC
8.8 m²BALC
8.8 m²BALC
8.9 m²BALC
9.7 m²BALC
10.5 m²BALC
10.5 m²BALC
11.0 m²BALC
BIN
STAIR
LIFT
CORRIDOR
40.3 m²
A2-BJ5.APT.01
40.8 m²
A2-BJ5.APT.02
41.9 m²
A2-B
J5.APT.03
52.0 m²
B1-BJ5.APT.04
49.9 m²
B1-BJ5.APT.05
49.8 m²
B1-B
J5.APT.06
47.5 m²
B1-DJ5.APT.07
51.7 m²
B1-AJ5.APT.08
51.9 m²
B1-AJ5.APT.09
54.6 m²
B1-AJ5.APT.10 41.5 m²
A2-BJ5.APT.11
40.4 m²
A2-BJ5.APT.12
40.4 m²
A2-B
J5.APT.13
40.4 m²
A2-BJ5.APT.14
40.4 m²
A4-A
J5.APT.15
10.4 m²BALC
10.1 m²BALC
10.3 m²BALC
10.1 m²BALC
11.1 m²BALC
10.5 m²BALC
10.2 m²BALC
10.5 m²BALC
8.6 m²BALC
8.6 m²BALC
8.6 m²BALC
8.6 m²BALC
8.6 m²BALC
8.6 m²BALC
8.6 m²BALC
BIN
LIFT
STAIR
CO
RR
IDO
R
9.5 m²BALC
8.4 m²BALC
38.9 m²BALC
35.0 m²BALC
35.0 m²BALC37.9 m²
BALC
11.0 m²BALC
8.2 m²BALC
10.7 m²BALC
10.7 m²BALC
BINPLANT
CORRIDOR
STAIR
LIFT
54.7 m²
B3-AE4.APT.01
74.1 m²
C2-BE4.APT.02
74.8 m²
C3-AE4.APT.03
72.2 m²
C3-AE4.APT.04
72.2 m²
C3-AE4.APT.05
74.0 m²
C3-AE4.APT.06
81.6 m²
C2-DE4.APT.07
74.8 m²
C2-AE4.APT.08 40.0 m²
A2-FE4.APT.09
40.0 m²
A2-FE4.APT.10
52.8 m²
B3-AL4.APT.01
40.8 m²
A2-B
L4.APT.02
50.3 m²
B7-B
L4.APT.03
49.7 m²
B2-AL4.APT.04
48.5 m²
B2-AL4.APT.05
48.4 m²
B2-A
L4.APT.0648.6 m²
B2-AL4.APT.07
49.4 m²
B2-AL4.APT.08
75.0 m²
C2-B
L4.APT.09
8.8 m²BALC
12.3 m²BALC
15.9 m²BALC
10.4 m²BALC
9.6 m²BALC
9.8 m²BALC
9.8 m²BALC
10.2 m²BALC
9.0 m²BALC
52.5 m²
B3-A
L4.APT.10
8.9 m²BALC
BINPLANT
CORRIDOR
LIFT
STAIR
RISER
SERVICESERVICE
1900
8.1 m²BALC
9.0 m²BALC
2240
2670
2240
2240
2230
2140
2230
2460
2460
2460
1900
1900
1800
1800
1800
1800
2070
2110
2060
1970
1970
2300
2040
2040
2460
1900
2260
2260
2260
2260
2260
2140
2010
2010
2010
2010
2010
2080
2060
2010
2070
2070
2240
SERVICES
1560
2000
SERVICES SERVICES SERVICES2000
1560
SERVICES SERVICES2000
1560
1560
2000
SERVICES
SERVICES
SERV
ICES
SERV
ICES
SERV
ICES
SERVICES
1560
20001532
2000
CO
RR
IDO
R
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 11:08:00 AM
C:\Users\rli\Documents\1187_AR_SITE MASTERPLAN_rli.rvt
18
02/08/20191:250
TP-A1607Site Level 5_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1607 [18]- Site Level 5_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/201914 TP REVISION 14 19/07/201915 TP REVISION 15 23/07/201917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
####
####
77.4 m²
C2-CHG.APT.03
72.9 m²
C2-A
HG.APT.0252.8 m²
B5-B
HG.APT.0173.9 m²
C2-AHG.APT.0577.6 m²
C2-C
HG.APT.04 77.5 m²
C2-C
MG.APT.0573.5 m²
C2-AMG.APT.06
79.4 m²
LOBBY
MG.LOB.01
STAIRLIFT BIN
53.8 m²
B5-AMG.APT.01
73.4 m²
C2-AMG.APT.02
72.7 m²
C2-A
MG.APT.03 76.7 m²
C2-CMG.APT.04
71.1 m²
C2-BFG.APT.02
72.5 m²
C2-B
FG.APT.01
LIFTS
STAIR
20.4 m²BALC
22.4 m²BALC
30.1 m²BALC 21.1 m²
BALC 22.7 m²BALC 22.5 m²
BALC21.3 m²BALC
29.7 m²BALC
20.6 m²BALC
21.2 m²BALC
22.7 m²BALC
11.6 m²BALC
11.5 m²BALC
12.2 m²BALC
73.0 m²
C2-B
FG.APT.03
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOMTYPE A - MINIMUM 1200mm X 1200MM ORTYPE B - MINIMUM 1000mm X 2700MM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
A or B
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 15, 28 Freshwater PlaceSouthbank, VIC 3006 Australia
Phone: +61 3 8327 8600Fax: +61 3 8327 8699
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
12/07/2019 9:22:52 AM
C:\Revit Local\1187_AR_SITE MASTERPLAN_lbailey.rvt
9
21/06/20191:250
TP-A1602Ground Level_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1602 [9]- Ground Level_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/2019
26 — CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS ARM ARCHITECTURE
SITE LEVEL 07 PLAN1:250 @A1/AUGUST 2019/TP-A1109
0m 5m 15m 30m 50m
STAIR
LIFT
56.3 m²
B3-EF6.APT.01
75.0 m²
C2-AF6.APT.02
76.2 m²
C2-AF6.APT.03
73.0 m²
C2-B
F6.APT.04
71.2 m²
C2-B
F6.APT.05
71.2 m²
C2-B
F6.APT.06
72.9 m²
C2-A
F6.APT.07
73.0 m²
C2-A
F6.APT.08
76.1 m²
C2-A
F6.APT.09
75.1 m²
C2-BF6.APT.10
90.7 m²
C5-AF6.APT.11
19.1 m²BALC
8.1 m²BALC
8.1 m²BALC
8.1 m²BALC
8.1 m²BALC
8.1 m²BALC
8.1 m²BALC
8.1 m²BALC
BIN
8.2 m²BALC
9.1 m²BALC
8.6 m²BALC
65.9 m²
B3-FG6.APT.01
90.4 m²
D2-AG6.APT.02
53.2 m²
B1-E
G6.APT.03
51.0 m²
B1-EG6.APT.04
51.0 m²
B1-EG6.APT.05
50.7 m²
B1-E
G6.APT.06
51.0 m²
B1-EG6.APT.07
51.0 m²
B1-EG6.APT.08
53.8 m²
B1-EG6.APT.09
75.4 m²
C2-AG6.APT.10
72.2 m²
C2-B
G6.APT.11
54.6 m²
B3-D
G6.APT.12BIN
STAIR
LIFT
9.2 m²BALC
9.7 m²BALC
9.6 m²BALC
8.7 m²BALC
8.6 m²BALC
9.7 m²BALC
9.9 m²BALC
9.6 m²BALC
9.7 m²BALC
12.9 m²BALC
15.6 m²BALC
10.7 m²BALC
40.1 m²
A2-DK6.APT.01
40.0 m²
A2-DK6.APT.02
40.8 m²
A2-DK6.APT.03
54.2 m²
B7-AK6.APT.04
54.2 m²
B1-A
K6.APT.05
53.0 m²
B1-A
K6.APT.06
49.2 m²
B1-DK6.APT.07
53.0 m²
B1-AK6.APT.08
50.9 m²
B1-B
K6.APT.09
50.9 m²
B1-BK6.APT.10
54.4 m²
B1-FK6.APT.1142.4 m²
A2-D
K6.APT.12
40.8 m²
A2-DK6.APT.13
40.8 m²
A2-DK6.APT.14
40.0 m²
A4-A
K6.APT.15
10.4 m²BALC
10.3 m²BALC
10.5 m²BALC
11.5 m²BALC
8.8 m²BALC
8.8 m²BALC
8.8 m²BALC
8.7 m²BALC
8.8 m²BALC
8.8 m²BALC
8.9 m²BALC
9.7 m²BALC
10.5 m²BALC
10.5 m²BALC
11.0 m²BALC
BIN
STAIR
LIFT
CORRIDOR
40.3 m²
A2-B
J6.APT.01
40.8 m²
A2-B
J6.APT.02
41.9 m²
A2-BJ6.APT.03
52.0 m²
B1-B
J6.APT.04
49.9 m²
B1-B
J6.APT.05
49.8 m²
B1-BJ6.APT.06
47.5 m²
B1-DJ6.APT.07
51.7 m²
B1-A
J6.APT.08
51.9 m²
B1-AJ6.APT.09
54.6 m²
B1-AJ6.APT.10 41.5 m²
A2-B
J6.APT.11
40.4 m²
A2-B
J6.APT.12
40.4 m²
A2-B
J6.APT.13
40.4 m²
A2-BJ6.APT.14
40.4 m²
A4-A
J6.APT.15
10.4 m²BALC
8.6 m²BALC
8.6 m²BALC
8.6 m²BALC
11.1 m²BALC
10.1 m²BALC
10.3 m²BALC
10.1 m²BALC
8.6 m²BALC
8.6 m²BALC
8.6 m²BALC
8.6 m²BALC
10.5 m²BALC
10.2 m²BALC
10.5 m²BALC
BIN
LIFT
STAIR
CO
RR
IDO
R
CO
RR
IDO
R
54.7 m²
B3-A
E5.APT.0174.1 m²
C2-BE5.APT.02
74.8 m²
C3-AE5.APT.03
72.2 m²
C3-AE5.APT.04
72.2 m²
C3-AE5.APT.05
74.0 m²
C3-AE5.APT.06
81.6 m²
C2-D
E5.APT.0774.8 m²
C2-AE5.APT.08
40.0 m²
A2-FE5.APT.09
40.0 m²
A2-FE5.APT.10
9.5 m²BALC
8.4 m²BALC
10.5 m²BALC
8.2 m²BALC
8.2 m²BALC
10.0 m²BALC
11.0 m²BALC
8.2 m²BALC
10.7 m²BALC
10.7 m²BALC
BINPLANT
CORRIDOR
LIFT
STAIR
8.9 m²BALC
21.3 m²BALC
11.2 m²BALC
9.6 m²BALC
9.8 m²BALC
9.8 m²BALC
10.2 m²BALC
9.0 m²BALC
8.9 m²BALC
BINPLANTLIFT
STAIR
CORRIDOR
52.7 m²
B3-A
L5.APT.0197.6 m²
D3-A
L5.APT.02
48.9 m²
B2-AL5.APT.03
48.5 m²
B2-AL5.APT.04
48.4 m²
B2-A
L5.APT.0548.6 m²
B2-AL5.APT.06
49.4 m²
B2-AL5.APT.07
75.0 m²
C2-B
L5.APT.0852.5 m²
B3-A
L5.APT.09
SERVICESERVICE
3020
9.0 m²BALC
47.2 m²
B3-B
E5.APT.11
2240
2240
2700
2240
2230
2230
21401900
1800
1800
1800
2110
2260
1350
1930
1350
22402140
2010
2070
2060
2060
1970
1970
2110
2520
2520
2520
SERVICES
1560
2000
SERVICES SERVICES SERVICES2000
1560
SERVICES SERVICES2000
1560
1560
2000
SERVICES
SERVICES
SERV
ICES
SERV
ICES
SERV
ICES
SERVICES
1560
20001532
2000
2010
2180
2010
2010
2010
2011
2011
1900
1900
2460
2257
2257
2257
2257
1900
2114
1800
2269
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 11:08:20 AM
C:\Users\rli\Documents\1187_AR_SITE MASTERPLAN_rli.rvt
18
02/08/20191:250
TP-A1608Site Level 6_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1608 [18]- Site Level 6_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/201914 TP REVISION 14 19/07/201915 TP REVISION 15 23/07/201917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
####
####
77.4 m²
C2-CHG.APT.03
72.9 m²
C2-A
HG.APT.0252.8 m²
B5-B
HG.APT.0173.9 m²
C2-AHG.APT.0577.6 m²
C2-C
HG.APT.04 77.5 m²
C2-C
MG.APT.0573.5 m²
C2-AMG.APT.06
79.4 m²
LOBBY
MG.LOB.01
STAIRLIFT BIN
53.8 m²
B5-AMG.APT.01
73.4 m²
C2-AMG.APT.02
72.7 m²
C2-A
MG.APT.03 76.7 m²
C2-CMG.APT.04
71.1 m²
C2-BFG.APT.02
72.5 m²
C2-B
FG.APT.01
LIFTS
STAIR
20.4 m²BALC
22.4 m²BALC
30.1 m²BALC 21.1 m²
BALC 22.7 m²BALC 22.5 m²
BALC21.3 m²BALC
29.7 m²BALC
20.6 m²BALC
21.2 m²BALC
22.7 m²BALC
11.6 m²BALC
11.5 m²BALC
12.2 m²BALC
73.0 m²
C2-B
FG.APT.03
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOMTYPE A - MINIMUM 1200mm X 1200MM ORTYPE B - MINIMUM 1000mm X 2700MM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
A or B
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 15, 28 Freshwater PlaceSouthbank, VIC 3006 Australia
Phone: +61 3 8327 8600Fax: +61 3 8327 8699
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
12/07/2019 9:22:52 AM
C:\Revit Local\1187_AR_SITE MASTERPLAN_lbailey.rvt
9
21/06/20191:250
TP-A1602Ground Level_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1602 [9]- Ground Level_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/2019
CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS — 27ARM ARCHITECTURE
SITE LEVEL 08 PLAN1:250 @A1/AUGUST 2019/TP-A1110
0m 5m 15m 30m 50m
54.7 m²
B3-A
E6.APT.01
9.5 m²BALC
74.1 m²
C2-B
E6.APT.02
8.4 m²BALC
74.8 m²
C3-A
E6.APT.0372.2 m²
C3-A
E6.APT.0472.2 m²
C3-AE6.APT.05
74.0 m²
C3-A
E6.APT.06
81.6 m²
C2-D
E6.APT.0774.8 m²
C2-AE6.APT.08
40.0 m²
A2-F
E6.APT.0940.0 m²
A2-F
E6.APT.10
10.5 m²BALC
8.2 m²BALC
8.2 m²BALC
10.0 m²BALC
11.0 m²BALC
8.2 m²BALC
10.7 m²BALC
10.7 m²BALC
BINPLANT
LIFT
STAIR
CORRIDOR
8.9 m²BALC
21.3 m²BALC
11.1 m²BALC
9.6 m²BALC
9.8 m²BALC
9.8 m²BALC
10.2 m²BALC
9.0 m²BALC
8.9 m²BALC
BINPLANT
CORRIDOR
LIFT
STAIR
52.7 m²
B3-AL6.APT.01
97.6 m²
D3-AL6.APT.02
49.0 m²
B2-A
L6.APT.0348.5 m²
B2-A
L6.APT.0448.4 m²
B2-A
L6.APT.0548.6 m²
B2-A
L6.APT.0649.4 m²
B2-A
L6.APT.07
75.0 m²
C2-B
L6.APT.08 52.5 m²
B3-AL6.APT.09
2120
2110
1800
20001800
30209.0 m²BALC
1800
2110
1970
1970
2070
2010
2060
SERVICES SERVICES SERVICES2000
1560
SERVICES SERVICES2000
1560
1801
2060
2269
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 4:09:03 PM
C:\Users\lzhang\Documents\1187_AR_SITE MASTERPLAN_lzhang7SPPH.rvt
18
02/08/20191:250
TP-A1609Site Level 7_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1609 [18]- Site Level 7_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/201914 TP REVISION 14 19/07/201915 TP REVISION 15 23/07/201917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
####
####
77.4 m²
C2-CHG.APT.03
72.9 m²
C2-A
HG.APT.0252.8 m²
B5-B
HG.APT.0173.9 m²
C2-AHG.APT.0577.6 m²
C2-C
HG.APT.04 77.5 m²
C2-C
MG.APT.0573.5 m²
C2-AMG.APT.06
79.4 m²
LOBBY
MG.LOB.01
STAIRLIFT BIN
53.8 m²
B5-AMG.APT.01
73.4 m²
C2-AMG.APT.02
72.7 m²
C2-A
MG.APT.03 76.7 m²
C2-CMG.APT.04
71.1 m²
C2-BFG.APT.02
72.5 m²
C2-B
FG.APT.01
LIFTS
STAIR
20.4 m²BALC
22.4 m²BALC
30.1 m²BALC 21.1 m²
BALC 22.7 m²BALC 22.5 m²
BALC21.3 m²BALC
29.7 m²BALC
20.6 m²BALC
21.2 m²BALC
22.7 m²BALC
11.6 m²BALC
11.5 m²BALC
12.2 m²BALC
73.0 m²
C2-B
FG.APT.03
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOMTYPE A - MINIMUM 1200mm X 1200MM ORTYPE B - MINIMUM 1000mm X 2700MM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
A or B
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 15, 28 Freshwater PlaceSouthbank, VIC 3006 Australia
Phone: +61 3 8327 8600Fax: +61 3 8327 8699
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
12/07/2019 9:22:52 AM
C:\Revit Local\1187_AR_SITE MASTERPLAN_lbailey.rvt
9
21/06/20191:250
TP-A1602Ground Level_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1602 [9]- Ground Level_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/2019
28 — CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS ARM ARCHITECTURE
SITE LEVEL 07 PLAN1:250 @A1/AUGUST 2019/TP-A1109
0m 5m 15m 30m 50m
54.7 m²
B3-A
E7.APT.0174.1 m²
C2-B
E7.APT.02
74.8 m²
C3-AE7.APT.03
72.2 m²
C3-AE7.APT.04
72.2 m²
C3-AE7.APT.05
74.0 m²
C3-AE7.APT.06
81.6 m²
C2-DE7.APT.07
74.8 m²
C2-A
E7.APT.0840.0 m²
A2-F
E7.APT.0940.0 m²
A2-FE7.APT.10
9.5 m²BALC
8.4 m²BALC
10.5 m²BALC
8.2 m²BALC
8.2 m²BALC
10.0 m²BALC
11.0 m²BALC
8.2 m²BALC
10.7 m²BALC
10.7 m²BALC
CORRIDOR
LIFT
STAIR
BINPLANT
52.7 m²
B3-A
L7.APT.0197.6 m²
D3-AL7.APT.02
49.8 m²
B2-A
L7.APT.0348.5 m²
B2-A
L7.APT.0448.4 m²
B2-A
L7.APT.0548.6 m²
B2-A
L7.APT.0649.4 m²
B2-A
L7.APT.07
75.0 m²
C2-B
L7.APT.0852.5 m²
B3-A
L7.APT.09
8.9 m²BALC
21.3 m²BALC
10.3 m²BALC
9.6 m²BALC
9.8 m²BALC
9.8 m²BALC
10.2 m²BALC
9.0 m²BALC
8.9 m²BALC
STAIR
LIFT
CORRIDOR
PLANTBIN
2110
2110
1800
1800
1800
9.0 m²BALC
47.2 m²
B3-B
E7.APT.11
3020
2010
2070
2110
1970
1970
2060
2060
2420
1800
SERVICES SERVICES SERVICES2000
1560
SERVICES SERVICES2000
1560
2269
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 4:14:13 PM
C:\Users\lzhang\Documents\1187_AR_SITE MASTERPLAN_lzhang7SPPH.rvt
18
02/08/20191:250
TP-A1610Site Level 8_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1610 [18]- Site Level 8_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/201914 TP REVISION 14 19/07/201915 TP REVISION 15 23/07/201917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
####
####
77.4 m²
C2-CHG.APT.03
72.9 m²
C2-A
HG.APT.0252.8 m²
B5-B
HG.APT.0173.9 m²
C2-AHG.APT.0577.6 m²
C2-C
HG.APT.04 77.5 m²
C2-C
MG.APT.0573.5 m²
C2-AMG.APT.06
79.4 m²
LOBBY
MG.LOB.01
STAIRLIFT BIN
53.8 m²
B5-AMG.APT.01
73.4 m²
C2-AMG.APT.02
72.7 m²
C2-A
MG.APT.03 76.7 m²
C2-CMG.APT.04
71.1 m²
C2-BFG.APT.02
72.5 m²
C2-B
FG.APT.01
LIFTS
STAIR
20.4 m²BALC
22.4 m²BALC
30.1 m²BALC 21.1 m²
BALC 22.7 m²BALC 22.5 m²
BALC21.3 m²BALC
29.7 m²BALC
20.6 m²BALC
21.2 m²BALC
22.7 m²BALC
11.6 m²BALC
11.5 m²BALC
12.2 m²BALC
73.0 m²
C2-B
FG.APT.03
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOMTYPE A - MINIMUM 1200mm X 1200MM ORTYPE B - MINIMUM 1000mm X 2700MM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
A or B
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 15, 28 Freshwater PlaceSouthbank, VIC 3006 Australia
Phone: +61 3 8327 8600Fax: +61 3 8327 8699
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
12/07/2019 9:22:52 AM
C:\Revit Local\1187_AR_SITE MASTERPLAN_lbailey.rvt
9
21/06/20191:250
TP-A1602Ground Level_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1602 [9]- Ground Level_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/2019
CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS — 29ARM ARCHITECTURE
SITE LEVEL 08 PLAN1:250 @A1/AUGUST 2019/TP-A1110
0m 5m 15m 30m 50m
54.7 m²
B3-AE8.APT.01
74.1 m²
C2-B
E8.APT.02
74.8 m²
C3-A
E8.APT.0372.2 m²
C3-A
E8.APT.0472.2 m²
C3-A
E8.APT.0574.0 m²
C3-A
E8.APT.06
81.6 m²
C2-DE8.APT.07
74.8 m²
C2-A
E8.APT.08 40.0 m²
A2-F
E8.APT.0940.0 m²
A2-F
E8.APT.10
9.5 m²BALC
8.4 m²BALC
10.5 m²BALC
8.2 m²BALC
8.2 m²BALC
10.0 m²BALC
11.0 m²BALC
8.2 m²BALC
10.7 m²BALC
PLANT BIN
STAIR
LIFT
CORRIDOR
52.7 m²
B3-A
L8.APT.01
97.6 m²
D3-A
L8.APT.02
49.8 m²
B2-AL8.APT.03
48.5 m²
B2-A
L8.APT.0448.4 m²
B2-A
L8.APT.0548.6 m²
B2-A
L8.APT.0649.4 m²
B2-A
L8.APT.07
75.0 m²
C2-B
L8.APT.0852.5 m²
B3-A
L8.APT.09
8.9 m²BALC
21.3 m²BALC
10.3 m²BALC
9.6 m²BALC
9.8 m²BALC
9.8 m²BALC
10.2 m²BALC
9.0 m²BALC
8.9 m²BALC
RISER
STAIR
LIFT
CORRIDOR
PLANTBIN
2060
1980
2120
2110
1800
10.7 m²BALC
9.0 m²BALC
2110
1800
1800
2230
3020
2070
1970
1800
SERVICES SERVICES SERVICES2000
1560
SERVICES SERVICES2000
1560
226920
10
2060
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 11:08:54 AM
C:\Users\rli\Documents\1187_AR_SITE MASTERPLAN_rli.rvt
18
02/08/20191:250
TP-A1611Site Level 9_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1611 [18]- Site Level 9_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/201914 TP REVISION 14 19/07/201915 TP REVISION 15 23/07/201917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
####
####
77.4 m²
C2-CHG.APT.03
72.9 m²
C2-A
HG.APT.0252.8 m²
B5-B
HG.APT.0173.9 m²
C2-AHG.APT.0577.6 m²
C2-C
HG.APT.04 77.5 m²
C2-C
MG.APT.0573.5 m²
C2-AMG.APT.06
79.4 m²
LOBBY
MG.LOB.01
STAIRLIFT BIN
53.8 m²
B5-AMG.APT.01
73.4 m²
C2-AMG.APT.02
72.7 m²
C2-A
MG.APT.03 76.7 m²
C2-CMG.APT.04
71.1 m²
C2-BFG.APT.02
72.5 m²
C2-B
FG.APT.01
LIFTS
STAIR
20.4 m²BALC
22.4 m²BALC
30.1 m²BALC 21.1 m²
BALC 22.7 m²BALC 22.5 m²
BALC21.3 m²BALC
29.7 m²BALC
20.6 m²BALC
21.2 m²BALC
22.7 m²BALC
11.6 m²BALC
11.5 m²BALC
12.2 m²BALC
73.0 m²
C2-B
FG.APT.03
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOMTYPE A - MINIMUM 1200mm X 1200MM ORTYPE B - MINIMUM 1000mm X 2700MM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
A or B
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 15, 28 Freshwater PlaceSouthbank, VIC 3006 Australia
Phone: +61 3 8327 8600Fax: +61 3 8327 8699
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
12/07/2019 9:22:52 AM
C:\Revit Local\1187_AR_SITE MASTERPLAN_lbailey.rvt
9
21/06/20191:250
TP-A1602Ground Level_Design Guidelines
Caulfield Village P2 VillageRESHAPE1187 CheckerAuthor
TP-A1602 [9]- Ground Level_Design Guidelines.pdf
Rev. No. Revision Description Date9 TP REVISION 09 21/06/2019
52 — CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS ARM ARCHITECTURE
CLEAR OPENING850
TYPE B
CLEA
R OP
ENIN
G
880
2640
1410
3300
2.7m
CEILI
NG H
EIGH
T
3960
3960
7510
3285
1910
CLEA
R OP
ENIN
G
880K-4
BALCONYAC
2700
1700
3545
3300
TYPE B
2680
CLEAR OPENING850
CLEA
R OP
ENIN
G
880
CLEA
R OP
ENIN
G
880
2700
1700
2.7m
CEILI
NG H
EIGH
T
3990
3300
7510
3300
3285
1910
BALCONY
AC
K-4
3400
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 11:06:48 AM
C:\Users\dwilson\Documents\1187_AR_SITE MASTERPLAN_dwilson.rvt
18
02/08/20191:50
A1808Apartment Type Plans & RCP - Type 17 & 18
Caulfield Village P2 VillageRESHAPE1187 RLLZ
A1808 [18]- Apartment Type Plans & RCP - Type 17 & 18.pdf
A1271 1 : 50
1 B5-A_TYPICAL 1 BED
A1231 1 : 50
2 B5-B_TYPICAL 1 BED
Rev. No. Revision Description Date12 TP REVISION 12 05/07/201916 TP REVISION 16 25/07/1917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
TYPE A
TYPE B
3000 1280 2700
3600
2.7m
CEILI
NG H
EIGH
T
4795
7510
2040
2230
9780
3200
1700
3300
9800
K-2
BALCONYAC
CLEAR OPENING850
CLEAR OPENING920
CLEA
R OP
ENIN
G
880
CLEA
R OP
ENIN
G
880
1900
3000
3000
3600
TYPE A
TYPE B
3000
5330
1900
3680
2700
3125
3600
3015
3110
2.7m CEILING HEIGHT5980
9775
BALCONY
AC
3000
CLEAR OPENING880
CLEAR OPENING880
K-2CL
EAR
OPEN
ING
920
3000 3650
CLEAR OPENING850
3600
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 11:07:58 AM
C:\Users\dwilson\Documents\1187_AR_SITE MASTERPLAN_dwilson.rvt
18
02/08/20191:50
A1815Apartment Type Plans & RCP - Type 31 & 32
Caulfield Village P2 VillageRESHAPE1187 RLLZ
A1815 [18]- Apartment Type Plans & RCP - Type 31 & 32.pdf
A1223 1 : 50
1 D2-A_TYPICAL 3 BED
A1266 1 : 50
2 D3-A_TYPICAL 3 BED
Rev. No. Revision Description Date12 TP REVISION 12 05/07/201916 TP REVISION 16 25/07/1917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS — 53ARM ARCHITECTURE
TYPE B
CLEAR OPENING850
CLEA
R OP
ENIN
G88
0
1450
4750
2700
1700
3720
2.7m
CEILI
NG H
EIGH
T43
95
6760
3300
2230
K-3
BALCONYAC
CLEA
R OP
ENIN
G88
0
3560
3300
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
1200
CLEAR OPENING850
2700
1700
2500
2.7m
CEILI
NG H
EIGH
T
3160
3300
2180
4845
5660
CLEA
R OP
ENIN
G
880
CLEA
R OP
ENIN
G
880
TYPE B
K-2
BALCONYAC
3260
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 11:06:40 AM
C:\Users\dwilson\Documents\1187_AR_SITE MASTERPLAN_dwilson.rvt
18
02/08/20191:50
A1807Apartment Type Plans & RCP - Type 15 & 16
Caulfield Village P2 VillageRESHAPE1187 RLLZ
A1807 [18]- Apartment Type Plans & RCP - Type 15 & 16.pdf
A1222 1 : 50
2 B3-F_TYPICAL 1 BED
Rev. No. Revision Description Date12 TP REVISION 12 05/07/201916 TP REVISION 16 25/07/1917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
A1214 1 : 50
1 B3-E_TYPICAL 1 BED
TYPE A
TYPE B
3000 1280 2700
3600
2.7m
CEILI
NG H
EIGH
T
4795
7510
2040
2230
9780
3200
1700
3300
9800
K-2
BALCONYAC
CLEAR OPENING850
CLEAR OPENING920
CLEA
R OP
ENIN
G
880
CLEA
R OP
ENIN
G
880
1900
3000
3000
3600
TYPE A
TYPE B
3000
5330
1900
3680
2700
3125
3600
3015
3110
2.7m CEILING HEIGHT5980
9775
BALCONY
AC
3000
CLEAR OPENING880
CLEAR OPENING880
K-2CL
EAR
OPEN
ING
920
3000 3650
CLEAR OPENING850
3600
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 11:07:58 AM
C:\Users\dwilson\Documents\1187_AR_SITE MASTERPLAN_dwilson.rvt
18
02/08/20191:50
A1815Apartment Type Plans & RCP - Type 31 & 32
Caulfield Village P2 VillageRESHAPE1187 RLLZ
A1815 [18]- Apartment Type Plans & RCP - Type 31 & 32.pdf
A1223 1 : 50
1 D2-A_TYPICAL 3 BED
A1266 1 : 50
2 D3-A_TYPICAL 3 BED
Rev. No. Revision Description Date12 TP REVISION 12 05/07/201916 TP REVISION 16 25/07/1917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
54 — CAULFIELD VILLAGE STAGES 7 & 8: APPENDIX J_ARCHITECTURAL DRAWINGS ARM ARCHITECTURE
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
1900
1200
CLEAR OPENING850
1900
2700
2.7m
CEILI
NG H
EIGH
T32
45
7510
2160
3400
3120
TYPE A K-4
BALCONYAC
CLEA
R OP
ENIN
G
920
CLEA
R OP
ENIN
G
880
3400
2700
1700
2430
2.7m
CEILI
NG H
EIGH
T
3245
7510
CLEAR OPENING850
1200
3970
2230
CLEA
R OP
ENIN
G
880
CLEA
R OP
ENIN
G
880
TYPE BK-4
BALCONY AC
3300
3055
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 11:06:33 AM
C:\Users\dwilson\Documents\1187_AR_SITE MASTERPLAN_dwilson.rvt
18
02/08/20191:50
A1806Apartment Type Plans & RCP - Type 13 & 14
Caulfield Village P2 VillageRESHAPE1187 RLLZ
A1806 [18]- Apartment Type Plans & RCP - Type 13 & 14.pdf
Rev. No. Revision Description Date12 TP REVISION 12 05/07/201916 TP REVISION 16 25/07/1917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019
A1203 1 : 50
1 B3-B_TYPICAL 1 BED
A1222 1 : 50
2 B3-D_TYPICAL 1 BED
TYPE A
TYPE B
3000 1280 2700
3600
2.7m
CEILI
NG H
EIGH
T
4795
7510
2040
2230
9780
3200
1700
3300
9800
K-2
BALCONYAC
CLEAR OPENING850
CLEAR OPENING920
CLEA
R OP
ENIN
G
880
CLEA
R OP
ENIN
G
880
1900
3000
3000
3600
TYPE A
TYPE B
3000
5330
1900
3680
2700
3125
3600
3015
3110
2.7m CEILING HEIGHT5980
9775
BALCONY
AC
3000
CLEAR OPENING880
CLEAR OPENING880
K-2CL
EAR
OPEN
ING
920
3000 3650
CLEAR OPENING850
3600
LEGEND - CIRCULATION
PASSAGEWAY CIRCULATION - ACCESSIBILITYMINIMUM WIDTH 1200mm
BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3000mm
LIVING AREA (2 OR MORE BEDROOMS)MINIMUM WIDTH 3600mmMINIMUM AREA 12sqm
CONFORMING TO THE APARTMENT GUIDELINES FOR VICTORIA
MAIN BEDROOMMINIMUM WIDTH 3000mmMINIMUM DEPTH 3400mm
LIVING AREA (1 BEDROOM) MINIMUM WIDTH 3300mmMINIMUM AREA 10sqm
BATHROOM1.CIRCULATION AREA MINIMUM 1200mm X 1200MM2.A SLIDE DOOR AND CLEAR 920mm OPENING3.HOBLESS SHOWER4.TOILET LOCATED IN THE CORNER OF THE ROOM
SNORKEL MINIMUM WIDTH 1200mmMAXIMUM DEPTH 1500mm
CROSS VENTILATION PATHMINIMUM DISTANCE TO OPENINGS 5000mmMAXIMUM DISTANCE TO OPENINGS 18000mm
LIVING AREA/BEDROOM (STUDIO)MINIMUM WIDTH 3300mmMINIMUM DEPTH 3400mm
TYPE A
TYPE B BATHROOM1.CIRCULATION AREA MINIMUM 1000mm X 2700MM2.A DOOR WITH REMOVABLE HINGES AND CLEAR 880mm DOOR OPENING3.HOBLESS SHOWER WITH REMOVABLE SHOWER SCREEN AND LOCATED ON THE FURTHEST WALL FROM THE DOOR OPENING4.TOILET LOCATED CLOSEST TO THE DOOR OPENING
0 10 20 30 40 50 60 70 80 90 100 mmMILLIMETRES ON ORIGINAL
REV.
DATE
DRAWING NO.
JOB NO.
DRAWN
SCALE
CHECKED
ON A1ALL DIMENSIONS ARE IN MILLIMETERS. DO NOT SCALE DRAWINGS. CHECK DRAWING IS TO SCALE BY MEASURING SCALE BAR BELOW. VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK, SHOP DRAWINGS, OR ORDERING ANY MATERIALS. TITLE
PROJECTCLIENT
T/ 03 8613 1888 F/ 03 8613 [email protected] 22 476 949 399www.armarchitecture.com.au
LEVEL 11/522 FLINDERS LANE MELBOURNE VICTORIA 3000 AUSGROUND, 470 ST KILDA ROADMELBOURNE, VIC 3004
NOTES
Level 2, 31 Queen Street, Melbourne VIC 3000Phone: +61 3 9614 7155Email: [email protected]
Level 22, 570 Bourke Street MELBOURNE VIC 3000Phone: +61 3 8554 7000Email: [email protected]
ARCHITECTCONSULTANTS
A1 841 x 594
2/08/2019 11:07:58 AM
C:\Users\dwilson\Documents\1187_AR_SITE MASTERPLAN_dwilson.rvt
18
02/08/20191:50
A1815Apartment Type Plans & RCP - Type 31 & 32
Caulfield Village P2 VillageRESHAPE1187 RLLZ
A1815 [18]- Apartment Type Plans & RCP - Type 31 & 32.pdf
A1223 1 : 50
1 D2-A_TYPICAL 3 BED
A1266 1 : 50
2 D3-A_TYPICAL 3 BED
Rev. No. Revision Description Date12 TP REVISION 12 05/07/201916 TP REVISION 16 25/07/1917 TP REVISION 17 31/07/1918 TP REVISION 18 02/08/2019