116,9° - pro-lite.co.uk Sample Test Report.pdf · 400 450 500 550 600 650 700 750 800 180 165 150...

8
400 450 500 550 600 650 700 750 800 180 165 150 135 120 105 90 75 60 45 30 15 0 15 30 45 60 75 90 105 120 135 150 165 116,9° Viso Systems Aps Copenhagen, Denmark www.visosystems.com Light efficiency: 109 Lumen/Watt Light quality: Color temperature: CRI: 84,3 3100 K Output: Peak: Power: PF: 1200 lm 399 cd 11,0 W 0,91 Beam angle CIE 1931 x: 0,430 y: 0,402 Product name: Demo panel explorer 3 Item number: PO130035 Date and time: 14-01-2016 13:36:22 Description: Has been measured from new shipping batch. Spectra Voltage: 227 V Current: 0,053 A Frequency: 50 Hz Power

Transcript of 116,9° - pro-lite.co.uk Sample Test Report.pdf · 400 450 500 550 600 650 700 750 800 180 165 150...

Page 1: 116,9° - pro-lite.co.uk Sample Test Report.pdf · 400 450 500 550 600 650 700 750 800 180 165 150 135 120 105 90 75 60 45 30 15 0 15 30 45 60 75 90 105 120 135 150 165 116,9° Viso

400 450 500 550 600 650 700 750 800

180 165150

135

120

105

90

75

60

45

3015015

30

45

60

75

90

105

120

135

150165

116,9°

Viso Systems Aps – Copenhagen, Denmark – www.visosystems.com

Light efficiency:

109 Lumen/Watt

Light quality:

Color temperature:

CRI: 84,3

3100 K

Output:

Peak:

Power:

PF:

1200 lm

399 cd

11,0 W

0,91

Beam angle

CIE 1931 x: 0,430 y: 0,402

Product name:

Demo panel explorer 3

Item number:

PO130035

Date and time:

14-01-2016 13:36:22

Description:

Has been measured from new shipping batch.

Spectra

Voltage: 227 V Current: 0,053 A Frequency: 50 Hz

Power

Page 2: 116,9° - pro-lite.co.uk Sample Test Report.pdf · 400 450 500 550 600 650 700 750 800 180 165 150 135 120 105 90 75 60 45 30 15 0 15 30 45 60 75 90 105 120 135 150 165 116,9° Viso

0,8

0,7

0,6

0,5

0,4

0,3

0,2

0,1

0,00,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7

2200

K

2700

K

3000

K

3500

K40

00 K

5000

K60

00 K

7000

K80

00 K

9000

K

1000

0 K

1200

0 K

1500

0 K

20000 K

40000 K

45046

0

470

480

490

500

510

520

530

540

550

560

570

580

590

600

610

620

630

2200

K

2700

K30

00 K

3500

K40

00 K

5000

K60

00 K

7000

K

8000

K

9000 K

10000 K

12000 K

15000 K

20000 K

40000 K

450

460

470

480

490

500

510

520

530

540

550

560

570

580

590

600

610

620

630

79

C1

81

C2

79

C3

90

C4

92

C5

94

C6

87

C7

92

C8

87

C9

79

C10

81

C11

85

C12

87

C13

78

C14

78

C15

75

C16

83

R1

93

R2

96

R3

82

R4

84

R5

91

R6

83

R7

62

R8

14

R9

84

R10

82

R11

73

R12

86

R13

98

R14

76

R15

79

Q1

95

Q2

84

Q3

80

Q4

83

Q5

85

Q6

85

Q7

87

Q8

95

Q9

91

Q10

87

Q11

84

Q12

83

Q13

73

Q14

75

Q15

Viso Systems Aps – Copenhagen, Denmark – www.visosystems.com

3100 K

CRI R values, only R1-R8 are used to calculate final CRI value R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 R15

83,3 93,1 95,6 82,1 83,5 91,3 83,3 61,9 13,8 84,0 81,6 73,2 85,9 98,3 75,9

TM30 C values, 16 binned values out of total of 99 C values C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16

78,6 81,1 79,2 90,0 92,2 93,9 87,0 91,6 86,8 78,9 80,6 85,5 86,8 78,4 78,0 75,1

CQS Q values Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 Q12 Q13 Q14 Q15

79,4 95,0 84,1 80,2 83,2 84,6 85,0 87,4 95,5 91,2 87,2 84,4 83,2 73,2 75,3

CQS: 83,3

Color temperature Color rendering index

Red component Color fidelity Color gamut Color quality scale

Color coordinate cie 1931

Color coordinate cie 1931

Color coordinate Color coordinate Color diviation from black body

CCT CRI CRI R9 TM30 Rf TM30 Rg CQS x y u v Δuv

3100 K 84,3 13,8 84,1 95,4 83,3 0,430 0,402 0,246 0,345 0,0008

TM30: 84,1 CRI: 84,3 (R1-R8)

Δuv: 0,0008

CIE 1931 ZOOM CIE 1931

x: 0,430 y: 0,402

Color parameters

Color details

Page 3: 116,9° - pro-lite.co.uk Sample Test Report.pdf · 400 450 500 550 600 650 700 750 800 180 165 150 135 120 105 90 75 60 45 30 15 0 15 30 45 60 75 90 105 120 135 150 165 116,9° Viso

7981 79

9092 94

8792

87

79 8185 87

78 7875

-11%-7%

-3%-1% -1%

1%

-6% -4% -5%-3%

2%

8%4% 4%

-4%-8%

Viso Systems Aps – Copenhagen, Denmark – www.visosystems.com

TM30 details C

ES

99

CE

S98

CE

S97

CE

S96

CE

S95

CE

S94

CE

S93

CE

S92

CE

S91

CE

S90

CE

S89

CE

S88

CE

S87

CE

S86

CE

S85

CE

S84

CE

S83

CE

S82

CE

S81

CE

S80

CE

S79

CE

S78

CE

S77

CE

S76

CE

S75

CE

S74

CE

S73

CE

S72

CE

S71

CE

S70

CE

S69

CE

S68

CE

S67

CE

S66

CE

S65

CE

S64

CE

S63

CE

S62

CE

S61

CE

S60

CE

S59

CE

S58

CE

S57

CE

S56

CE

S55

CE

S54

CE

S53

CE

S52

CE

S51

CE

S50

CE

S49

CE

S48

CE

S47

CE

S46

CE

S45

CE

S44

CE

S43

CE

S42

CE

S41

CE

S40

CE

S39

CE

S38

CE

S37

CE

S36

CE

S35

CE

S34

CE

S33

CE

S32

CE

S31

CE

S30

CE

S29

CE

S28

CE

S27

CE

S26

CE

S25

CE

S24

CE

S23

CE

S22

CE

S21

CE

S20

CE

S19

CE

S18

CE

S17

CE

S16

CE

S15

CE

S14

CE

S13

CE

S12

CE

S11

CE

S10

CE

S09

CE

S08

CE

S07

CE

S06

CE

S05

CE

S04

CE

S03

CE

S02

CE

S01

Color Evaluation Sample

100

80

60

40

20

0

Fid

eli

ty In

dex, R

f

100

90

80

70

60

50

20%

15%

10%

5%

0%

-5%

-10%

-15%

-20%

Color distortion graphics

Color vector graphics

Hue bin

Hue bin

Ch

rom

a s

hif

t b

y h

ue

R

f b

y h

ue

140

130

120

110

100

90

80

70

60 50 60 70 80 90 100

Rg

Rf

Graphic shifts (%)

Hue Bin Rf Chroma Hue

1 79 -11% 1%

2 81 -7% 6%

3 79 -3% 9%

4 90 -1% 5%

5 92 -1% 2%

6 94 1% -2%

7 87 -6% -4%

8 92 -4% 1%

9 87 -5% 6%

10 79 -3% 10%

11 81 2% 12%

12 85 8% 1%

13 87 4% -8%

14 78 4% -15%

15 78 -4% -12%

16 75 -8% -16%

Rf 84,1

Fidelity index Rf

Rg 95,4

Gammut index Rg

Approx. limits for sources on the Planckian locus.

Approx. limits for practical light sources.

1

2

1 2

Page 4: 116,9° - pro-lite.co.uk Sample Test Report.pdf · 400 450 500 550 600 650 700 750 800 180 165 150 135 120 105 90 75 60 45 30 15 0 15 30 45 60 75 90 105 120 135 150 165 116,9° Viso

Viso Systems Aps – Copenhagen, Denmark – www.visosystems.com

Beam intensities from 1-20m 1m 2m 3m 4m 5m 6m 7m 8m 9m 10m 11m 12m 13m 14m 15m 16m 17m 18m 19m 20m

3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 19,7ft 23ft 26,2ft 29,5ft 32,8ft 36,1ft 39,4ft 42,7ft 45,9ft 49,2ft 52,5ft 55,8ft 59,1ft 62,3ft 65,6ft

399lx 100lx 44lx 25lx 16lx 11lx 8lx 6lx 5lx 4lx 3lx 3lx 2lx 2lx 2lx 2lx 1lx 1lx 1lx 1lx

37,1fcd 9,3fcd 4,1fcd 2,3fcd 1,5fcd 1fcd 0,8fcd 0,6fcd 0,5fcd 0,4fcd 0,3fcd 0,3fcd 0,2fcd 0,2fcd 0,2fcd 0,1fcd 0,1fcd 0,1fcd 0,1fcd 0,1fcd

Intensities in 0° c-plane 0° 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60° 65° 70° 75° 80° 85° 90° 95°

399 398 394 386 376 363 346 327 305 281 253 223 190 155 119 81 46 17 2 1

100% 100% 99% 97% 94% 91% 87% 82% 76% 70% 63% 56% 48% 39% 30% 20% 11% 4% 1% 0%

Intensities in 90° c-plane

0° 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60° 65° 70° 75° 80° 85° 90° 95°

399 398 393 385 375 362 345 326 304 279 251 220 187 152 115 79 47 19 2 1

100% 100% 98% 97% 94% 91% 87% 82% 76% 70% 63% 55% 47% 38% 29% 20% 12% 5% 1% 0%

Intensities in 180° c-plane

0° 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60° 65° 70° 75° 80° 85° 90° 95°

399 398 394 386 376 363 346 327 305 281 253 223 190 155 119 81 46 17 2 1

100% 100% 99% 97% 94% 91% 87% 82% 76% 70% 63% 56% 48% 39% 30% 20% 11% 4% 1% 0%

Intensities in 270° c-plane

0° 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60° 65° 70° 75° 80° 85° 90° 95°

399 398 393 385 375 362 345 326 304 279 251 220 187 152 115 79 47 19 2 1

100% 100% 98% 97% 94% 91% 87% 82% 76% 70% 63% 55% 47% 38% 29% 20% 12% 5% 1% 0%

Beam angle 50% Field angle 10% Cutoff angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

116,9° 161,9° 174° 77,7% 52,2%

1 m 3,3 ft

2 m 6,6 ft

3 m 9,8 ft

4 m 13,1 ft

5 m 16,4 ft

Distance (meter) Distance (feet)

16,3 m 53,4 ft

116,9°

13 m 42,7 ft

9,8 m 31,9 ft

6,5 m 21,5 ft

3,3 m 10,7 ft

Lux*

Footcandles*

*measured at center of beam

Beam width (meter) Beam width (feet)

16 lx

25 lx

44 lx

100 lx

399 lx

1 fcd

2 fcd

4 fcd

9 fcd

37 fcd

Beam center

Beam details

Page 5: 116,9° - pro-lite.co.uk Sample Test Report.pdf · 400 450 500 550 600 650 700 750 800 180 165 150 135 120 105 90 75 60 45 30 15 0 15 30 45 60 75 90 105 120 135 150 165 116,9° Viso

90°

75°

60°

45°

30°

15°

-15°

-30°

-45°

-60°

-75°

180m 590,6f

144m 472,4f

108m 354,3f

72m 236,2f

36m 118,1f

0m 0f

-36m -118,1f

-72m -236,2f

-108m -354,3f

-144m -472,4f

Viso Systems Aps – Copenhagen, Denmark – www.visosystems.com

ISO Diagrams

ISO candela diagram

ISO lux diagram

10%

20%

30%

40%

50%

60%

70%

80%

90%

Conditions:

Number of c-planes: 8

Candela at center: 399 cd

3%

5%

10%

30%

50%

40 cd

80 cd

120 cd

160 cd

200 cd

240 cd

279 cd

319 cd

359 cd

0,120 lx

0,200 lx

0,399 lx

1,20 lx

2,00 lx

Conditions:

Number of c-planes: 8

Lux at center: 3,99 lx

Lux distribution on a surface when lamp is mounted at 10 meters from the surface.

Horizontal angels

Vert

ica

l a

ng

els

Mounting height: 10 meters (33 feet)

Page 6: 116,9° - pro-lite.co.uk Sample Test Report.pdf · 400 450 500 550 600 650 700 750 800 180 165 150 135 120 105 90 75 60 45 30 15 0 15 30 45 60 75 90 105 120 135 150 165 116,9° Viso

Viso Systems Aps – Copenhagen, Denmark – www.visosystems.com

Glare Evaluation According to UGR

UGR

p Ceiling 70 70 50 50 30 70 70 50 50 30

p Walls 50 30 50 30 30 50 30 50 30 30

p Floor 20 20 20 20 20 20 20 20 20 20

Room size

X Y

Viewing direction at right angles to lamp axis

Viewing direction parallel to lamp axis

2H 2H 15,8 17,1 16,1 17,3 17,6 15,8 17,1 16,1 17,3 17,6

3H 17,4 18,6 17,7 18,8 19,1 17,4 18,6 17,7 18,8 19,1

4H 18,0 19,1 18,3 19,4 19,7 18,0 19,1 18,3 19,4 19,7

6H 18,4 19,4 18,7 19,7 20,1 18,4 19,4 18,7 19,7 20,1

8H 18,5 19,5 18,9 19,8 20,2 18,5 19,5 18,9 19,8 20,2

12H 18,5 19,5 18,9 19,9 20,2 18,5 19,5 18,9 19,9 20,2

4H 2H 16,5 17,6 16,8 17,9 18,2 16,5 17,6 16,8 17,9 18,2

3H 18,2 19,2 18,6 19,6 19,9 18,2 19,2 18,6 19,6 19,9

4H 19,0 19,8 19,4 20,2 20,6 19,0 19,8 19,4 20,2 20,6

6H 19,5 20,2 19,9 20,6 21,0 19,5 20,2 19,9 20,6 21,0

8H 19,6 20,3 20,1 20,7 21,2 19,6 20,3 20,1 20,7 21,2

12H 19,7 20,4 20,2 20,8 21,2 19,7 20,4 20,2 20,8 21,2

8H 4H 19,3 19,9 19,7 20,4 20,8 19,3 19,9 19,7 20,4 20,8

6H 19,9 20,5 20,4 20,9 21,4 19,9 20,5 20,4 20,9 21,4

8H 20,1 20,6 20,6 21,1 21,6 20,1 20,6 20,6 21,1 21,6

12H 20,3 20,7 20,8 21,2 21,7 20,3 20,7 20,8 21,2 21,7

12H 4H 19,3 19,9 19,7 20,3 20,8 19,3 19,9 19,7 20,3 20,8

6H 19,9 20,4 20,4 20,9 21,4 19,9 20,4 20,4 20,9 21,4

8H 20,2 20,6 20,7 21,1 21,6 20,2 20,6 20,7 21,1 21,6

Variation of the observer position for the luminaire distance S

S = 1,0H +0,1 / -0,1 +0,1 / -0,1

S = 1,5H +0,2 / -0,3 +0,2 / -0,3

S = 2,0H +0,4 / -0,7 +0,4 / -0,7

Standard table BK06 BK06

Correction summand

3,0 3,0

Corrected glare indices referring to 1200 lm total luminous flux

Page 7: 116,9° - pro-lite.co.uk Sample Test Report.pdf · 400 450 500 550 600 650 700 750 800 180 165 150 135 120 105 90 75 60 45 30 15 0 15 30 45 60 75 90 105 120 135 150 165 116,9° Viso

H=7

H=7H=6

H=6

H=5

H=5

H=4

H=4

Viso Systems Aps – Copenhagen, Denmark – www.visosystems.com

Ceiling

reflectance 80 70 50 30 10 0

Wall

reflectance 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

Floor

reflectance 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 0

RCR (RCR: Room Cavity Ratio) Room Values are expressed as percentage of Lumens delivered to the task surface

0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 101 101 101 99

1 108 104 99 95 106 101 97 94 97 94 91 93 90 88 89 87 85 83

2 98 90 83 77 96 88 82 76 84 79 74 81 77 73 78 74 71 69

3 90 79 71 64 87 77 70 63 74 68 62 71 66 61 69 64 60 58

4 82 70 61 54 79 68 60 54 66 58 53 63 57 52 61 56 51 49

5 75 62 53 46 73 61 52 46 59 51 45 57 50 45 55 49 44 42

6 69 56 47 40 67 55 46 40 53 45 40 51 44 39 50 44 39 37

7 64 51 42 35 62 50 41 35 48 41 35 47 40 35 45 39 34 32

8 60 46 37 32 58 45 37 31 44 37 31 43 36 31 41 35 31 29

9 56 42 34 28 54 42 34 28 40 33 28 39 33 28 38 32 28 26

10 52 39 31 26 51 38 31 26 37 30 25 36 30 25 35 29 25 23

Light planning

Coefficients of Utilization

Luminaire budgetary diagram

10 20 30 40 50 70 100 200 300 500 700 1K 2K 3K 4K 5K 7K 2

3

4

5

6

7

8 9

10

20

50

30

40

LAMPS (number of lamps)

AREA m2 (area of the room)

Conditions

H = Room height

Hdown Lamp distance from ceiling 0.00m

Hwork Work area height from floor 0.00m

Ework Average lux on work area 100lx

p(%) Ceiling reflectance

Wall reflectance

Floor reflectance

70 50 30

50 30 20

0°-10° 10°-20° 20°-30° 30°-40° 40°-50° 50°-60° 60°-70° 70°-80° 80°-90°

37,8 lm 109 lm 167 lm 204 lm 216 lm 198 lm 152 lm 84,7 lm 21,9 lm

90°-100° 100°-110° 110°-120° 120°-130° 130°-140° 140°-150° 150°-160° 160°-170° 170°-180°

1,13 lm 1,09 lm 1,29 lm 1,42 lm 1,43 lm 1,35 lm 1,06 lm 0,688 lm 0,239 lm

Zonal Lumen Summary

Page 8: 116,9° - pro-lite.co.uk Sample Test Report.pdf · 400 450 500 550 600 650 700 750 800 180 165 150 135 120 105 90 75 60 45 30 15 0 15 30 45 60 75 90 105 120 135 150 165 116,9° Viso

4 min24 sec

8 min48 sec

13 min13 sec

17 min37 sec

22 min2 sec

26 min26 sec

30 min50 sec

35 min15 sec

39 min39 sec

44 min4 sec

100%

90,8%

97,7%

95,4%

93,1%

Viso Systems Aps – Copenhagen, Denmark – www.visosystems.com

Stabilization

Warmup curve

Warmup time: 44 min 12 sec

Warmup variation -9,3%

Stable period: 15 min

Stable change max: 0,5%

Minimum time: 30 min

CCT start CCT change CCT end

3017 K +83 K 3100 K

Output start Output change Output end

1318 lm -118 lm 1200 lm

Warmup result

Warmup conditions

Color temperature change

Output change