1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... ·...

27
Product Portfolio Consensus Hip Systems Consensus Knee Systems

Transcript of 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... ·...

Page 1: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

Product Portfolio1115 Windfield Way, Suite 100El Dorado Hills, Ca 95762 916-355-7100, 916-355-7190 [email protected] consensusortho.com

Consensus Hip Systems

Consensus Knee Systems

Page 2: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

Table of Contents

About Consensus ...................................................................................................................................................... I-IIIConsensus Knee System ...............................................................................................................................................1Bespoke (PSI) ......................................................................................................................................................................3Revision Knee System ....................................................................................................................................................5Mobile Bearing Knee .......................................................................................................................................................7TaperSet Hip System ......................................................................................................................................................9CS2 Acetabular Cup System ..................................................................................................................................... 11Bespoke (ACO) ................................................................................................................................................................ 13Consensus Hip System ............................................................................................................................................... 15UniSyn Hip System ....................................................................................................................................................... 17References ....................................................................................................................................................................... 18

Product Portfolio

Page 3: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,
Page 4: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

About Consensus

ReliAbilityOur company name is our identity, our values defined simply. We manufacture the highest quality industry standard medical devices. We want your patients back on their feet quickly and reliably.

integRityThe orthopedic industry is constantly evolving and maturing. With multiple patents and a history of product reliability, Consensus is committed to developing industry best practices throughout the organization.

teAmwoRkWe strive to help and improve the lives of patients, medical professionals, and our surrounding communities. Working together is essential in creating high quality medical devices that exceed industry expectations.

Located in northern California, Consensus Orthopedics is committed to providing proven and reliable total joint implants and instruments to the global market. Consensus headquarters include administrative offices, research and design facilities, manufacturing, inspection, clean room and warehouse space. With over 20 years of orthopedic design and manufacturing experience, together, through a focus on patient care and clinician relationships, Consensus is dedicated to creating one team, focused on restoring mobility and renewing lives.

CONSENSUSORTHOPEDICS

I

Page 5: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

CONSENSUSORTHOPEDICS

II

Page 6: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

CONSENSUSORTHOPEDICS

III

QuiCk stAts

1115 Windfield Way, Suite 100El Dorado Hills, Ca 95762 916-355-7100, 916-355-7190 [email protected] consensusortho.com

45,000+ Knees implanted

30,000+

Hips implanted

100% Designed, developed, and

manufactured in the United States

10+ Countries where Consensus products are sold

Page 7: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

The Consensus® Knee System has been implanted in over 45,000 patients. Developed on a foundation of established design principles, proven clinical experience, and intelligent engineering, the Consensus Knee System provides long term stability and natural motion.

CONSENSUSORTHOPEDICS

1

CO

NSEN

SUS K

NEE SY

STEM

Consensus Knee VitalitEThrough a blended process, VitalitE cross linked inserts demonstrate a technologically advanced material ensuring all of the desired polyethylene characteristics are maximized, with no compromises.

VitalitE inserts are more resistant to oxidation than conventional crosslinked UHMWPE1

VitalitE cross linked inserts demonstrated a 35% reduction in wear when compared with conventional UHMWPE

Oxidative Stability Ultra-low Wear

0.037

0.0375

0.038

0.0385

0.035

0.04

0

5

10

15

20

Conventional UHMWPE Conventional UHMWPE (mg/MC)VitalitE VitalitE (mg/MC)

35% Less

Page 8: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

Anatomic Patella TrackingDeepend patella track with 6° “Q” angle

Reduced Lateral Profile“Patient-matched” sizing reduces hangover

VitalitE InsertsVitamin E blended CR and Ultracongruent Inserts

“Locks” InDovetail locking mechanism features a four point locking system

Anatomical PatellaProvides dome medialization and optimal bony coverage

Optimal CoveragePatented medialized & anterior stem location

The Anatomic TibialComponent minimizes soft tissue impingement while providing optimal peripheral fit

CONSENSUSORTHOPEDICS

2

Insert Options• Congruent• Ultracongruent• Posterior Stabilized

CO

NSE

NSU

S K

NEE

SY

STEM

Page 9: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

Covering a range of surgical approaches, the Bespoke Patient Specific Instrumentation knee guides addresses optimal implant positioning and sizing creating a personalized anatomical fit.

Using an MRI image-based approach Bespoke PSI allows the surgeon to preoperatively plan and visualize their patient’s knee surgery in three dimensions, creating personalized patient-specific surgical positioning guides.

Drop Rod Connection BoxVisually confirm correct alignment.

Finger-pit Pressure PointA patented and proprietary technology that provides accurate positioning of the Bespoke PSI guide with one push location.

Baseplate Central WindowAllowing the surgeon to view and ensure proper seating of the guide with minimal obstruction.

Proximal resestion level referenceAllows accurate varus/valgus alignment.

CONSENSUSORTHOPEDICS

3

PATIEN

T SPEC

IFIC IN

STRU

MEN

TATIO

N

Page 10: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

AP and EPI Anatomical ReferencesHelps visually confirm rotational alignment and posterior distal flaps parallel to EPI line.

SurgiCase Planning Software Utilizes MRI imaging incorporating anatomical and mechanical axis alignment philosophies. The intuitive layout of SurgiCase provides 2D and 3D preoperative visualization options to fine-tune implant size and position and create Bespoke PSI knee guides.

Rotational medial and lateral pin cylinderAccurately establishes A/P and tibial external rotation including a drop rod connection box to visually confirm alignment.

Proximal resestion level referenceAllows accurate varus/valgus alignment.

CONSENSUSORTHOPEDICS

4

PATI

ENT

SPEC

IFIC

INST

RU

MEN

TATI

ON

Page 11: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

The Revision Knee System is designed to deliver a reliable and streamlined revision system providing optimal results. Based on the Consensus Knee System, the Revision Knee addresses many types of revision procedures.

The articulating surfaces are unchanged between our primaryConsensus Knee System and the Revision Knee System,allowing for complete modularity when revising the femoral ortibial components

CONSENSUSORTHOPEDICS

5

Tibial ComponentAnatomic medialized stem2 avoids impingement on lateral and posterior bone while the stem provides additional stability.Modular 5 and 10 mm medial and lateral augments available

REV

ISION

KN

EE SYSTEM

Tibial InsertsCongruent design enhances joint stability and increases contact area to reduce wear.

Page 12: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

StemsStems are available in multiple lengths and diameters:• 80mm, 110mm, and 150 mm stems• 10mm to 22mm diameters

CONSENSUSORTHOPEDICS

6

Femoral ComponentStem has been offset medially to match the natural anatomy including a valgus stem angle of 6° in the coronal plane.Modular 5mm posterior and distal augments available

Augments, Screw & Pegs• Femoral augments are 5 mm thick• Tibial augments are offered in 5

and 10 mm thickness• Augments can be affixed with

either a screw or peg

REV

ISIO

N K

NEE

SY

STEM

Page 13: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

The Consensus® Mobile Bearing Knee System* has been developedon the foundation of the Consensus® Knee System with its reliable clinical experience and intelligent engineering.

This rotating platform design expands the Consensus® Knee System implant offerings by providing surgeons with a dual articulation total knee helping to reduce wear and improve natural kinematics

The Consensusmobile-bearing knee ultracongruentinsert can rotate shortdistances inside thehighly polished tibial tray. This is designed to allow patients a few degrees of greater rotation to the medial and lateral sides of their knee.

Designed with complete compatibilty with the Consensus Knee CR femur, the mobile bearing knee system is intended to more closely replicate normal knee motion.

CONSENSUSORTHOPEDICS

7

MO

BILE B

EAR

ING

KN

EE

*Not for sale in the US

Page 14: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

Polished Tibial projectionAssure a stable locking mechanism and reduce poly wear.

Ultracongruent InsertProvides stability without additional bone loss, and improves femoral rollback

Highly polished surfaceImproved wear properties

Anatomical medialized cruciate stem4

Avoids impingement on lateral and posterior bone; cruciate stem provides superior stability.

Porous Titanium Surface Technology3 optional

Anatomic Patella TrackingDeepened patellar groove reduces lateral stress on patella

CONSENSUSORTHOPEDICS

8

MO

BIL

E B

EAR

ING

KN

EE

*Not for sale in the US

Page 15: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

The TaperSet Hip System features a reduced distal profile stem (RDP) which is designed to accommodate femurs with proximal-distal mismatch. The TaperSet RDP stem’s reduced distal profile improves the proximal fit of the implant in the metaphysis. This unique reduced profile is the ideal choice to address a proximal/distal mismatch.

Dual Taper Wedge Geometry provides stability in both mediolateral and anteroposterior planes

Ti-6Al-4V AlloyProven biocompatibility without excessive stiffness

Reduced Distal Profile (RDP) Stems are available to address proximal/distal mismatch of the femur.

Lateral Offset Options to restore biomechanics without lengthening the leg

CONSENSUSORTHOPEDICS

9

TAP

ERSET H

IP SY

STEM

Page 16: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

Lateral Offset Options to restore biomechanics without lengthening the leg

Porous Plasma SprayProximal circumferentialcoating provides for biological fixation at the implant-bone interface

135° Neck Angle Allows for restoration of joint mechanics

Reduced Distal Profile (RDP) Stems

Acetabular Options Cup with Insert

Standard OffsetOptions to restore biomechanics without lengthening the leg

CONSENSUSORTHOPEDICS

10

TAP

ERSE

T H

IP S

YST

EM

Page 17: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

Cross-Linked Polyethelyene, Neutral with 0°, 10° or 20° Hoods

Cross-Linked Polyethelyene,Lateralized with 0°, 10° or 20° Hoods

The CS2 Acetabular Cup System is designed to help restore natural kinematics. The system offers a wide range of options to help address both primary and revision surgeries.

The CS2 system is available with VitalitE crosslinked poly. After 5 million cycles, VitalitE crosslinked poly has shown a 78% reduction in abrasive wear compared to cross-linked UHMWPE poly.

Vitamin E Vitamin E

Liners

CONSENSUSORTHOPEDICS

11

Consensus Hip VitalitEBlended with vitamin-e, a natural antioxidant, VitalitE cross-linked liners deliver long-term oxidative stability and enhanced mechanical performance, including ultra-low wear.

VitalitE liners demonstrated a 78% reduction in abrasive wear

VitalitE Liners retain their long term mechanical performance

CS2

AC

ETAB

ULA

R C

UP

SYSTEM

Abrasive WearPreserved Mechanical Performance

0

15

30

45

60

0

20

40

60

80

100

78% Less

Conventional UHMWPE (mg/MC)VitalitE (mg/MC)

Impact Strength (KJ/m2)Ultimate Strength (N)

Tensile Strength (MPa)

Non Aged Aged 14 Days Aged 28 Days

Page 18: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

Multiple Shell OptionsHemispherical and Flared rim design improves press-fit.

Multiple Hole OptionsNo Holes, Cluster Holes, and Multi holes

Enhanced FixationThe irregular sintered bead coating enhances initial stability as well as long-term biological fixation.

Secure LockLiner locking mechanism allows 12 liner positions to maximize ROM and minimize dislocations

CONSENSUSORTHOPEDICS

12

CS2

AC

ETA

BU

LAR

CU

P S

YST

EM

Page 19: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

Acetabular Cup Orientation GuidesRELIABLE CUP ORIENTATION FOR EVERY PATIENTObtaining the intended cup orientation is crucial for reaching an optimal functional outcome for patients. At the same time, it is also one of the most challenging aspects of Total Hip Arthroplasty. Studies indicate that 20 to 53%5 of conventional freehand THA surgeries result in a cup orientation that deviates more than 10° from the intended cup orientation. The use of patient-specific guides could significantly improves this outcome. A study6 on a similar device comparing 38 patients treated with conventional THA against 31 patients treated with surgical guides shows no outliers in the group treated with guides.

CONSENSUSORTHOPEDICS

13

AC

ETAB

ULA

R C

UP

OR

IENTA

TION Bone model of the acetabulum as easy

reference for guide placementCase identifier on surgical guide and bone model for traceability to one unique patient and surgeon

Optimized Contact Surfaces

Anatomical References

Recognizable Anatomical Model

Pinhole for Visual Guiding Pin

Detachable Connection

Registration Features for unique, stable fit

Page 20: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

Software• Fast planning of the orientation and size of acetabular cups based on

pelvic coordinate system• Visualize volume of bone to be reamed• Intuitive user interface

CONSENSUSORTHOPEDICS

14

AC

ETA

BU

LAR

CU

P O

RIE

NTA

TIO

NIncludes fast and easy-to-use planning software and patient-specific surgical guides. The ACO guides place a visual alignment pin in an orientation corresponding to the intended orientation of the cup implant. Without interfering with the normal surgical procedure and adding limited additional surgery time, this pin offers a reliable visual reference to align the impactor to, independent of whether the patient is oriented accurately on the operating table. This helps surgeons achieve accurate cup orientation. Ensuring accurate cup orientation helps reduce dislocation rate7 and impingement, and prevents accelerated wear and early failure of the implant8.

The Acetabular Cup Orientation (ACO) System

Pinhole for Visual Guiding Pin

Detachable Connection

Registration Features for unique, stable fit

Page 21: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

For over 20 years, the Consensus Hip System has provided proven fit and fill stems developed from well established design principles. Designed to help restore patient biomechanics, the Consensus Hip System offers a wide variety of implant options for all types of patients.

Full Porous Coated Collar Enhances stability and initial bone fixation. Also available as a collarless option

Fully Circumferential Plasma Spray Ti Coated

Ti-6Al-4VStems have proven biocompatibilitywithout excessive stiffness

Polished Distal BulletsReduce cortical impingement

The design philosophy of the Consensus system is to restore the original anatomic position of the femoral shaft to the acetabulum. The stem is designed to facilitate restoration of a wide variety of femoral geometries.

Consensus press fit porous coated Ti stems incorporate:• Nonporous areas,

including the distal stem, have a smooth finish to minimize wear due to micro-motion between the bone and stem.

CONSENSUSORTHOPEDICS

15

CO

NSEN

SUS H

IP SY

STEM

Page 22: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

Full Porous Coated Collar Enhances stability and initial bone fixation. Also available as a collarless option

Fully Circumferential Plasma Spray Ti Coated

Ti-6Al-4VStems have proven biocompatibilitywithout excessive stiffness

128° Neck Angle Fulfills both high and lateral offsets

Trapezoidal Polished NecksIncreases ROM and reduces the potential for impingement

The Consensus stem incorporates a compound proximal wedge (CPW) design. The stem is tapered in the sagittal, coronal, and transverse plane. The effect of the CPW design improves load transfer for both the cementless and cemented stem applications.

Consensus cemented CoCr stem combines:• A compound proximal wedge body• Cement normalization steps• Wrap around collar to preserve

proximal bone• Grit blast proximal body• Distal grooves and a tapered distal

stem CONSENSUSORTHOPEDICS

16

CO

NSE

NSU

S H

IP S

YST

EM

Page 23: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

The Consensus Orthopedics UniSyn™ Hip System has been designed with total flexibility in mind. All components are completely interchangeable. This allows for independent adjustment of both the size and orientation of the necks, bodies and stems.

Multiple Stem OptionsCountless stem diameters and lengths to match any patients needs

All three components can be individually fit to specifically match the patients’ anatomy.  The UniSyn Hip was designed to address every surgical challenge encountered in primary or revision surgery.

Surgery is simplified by providing multiple surgical options and streamlined surgical techniques.

The UniSyn™ Hip System Completely interchangeable, limitless implant options

CONSENSUSORTHOPEDICS

17

UN

ISYN

HIP

SYSTEM

Page 24: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

Multiple Stem OptionsCountless stem diameters and lengths to match any patients needs

The UniSyn Hip System features patented9 connection technology that allows the surgeon to independently fit the diaphysis and metaphysis, and then select the neck component that will best restore length, offset and anteversion of the patient’s hip joint.

6 Proximal Body Options Multiple medial projection options for each cone size

Independent Neck and BodyAllows for 360 degrees of version with the use of Modular Neck Vertical Lengths, or Lateral Offsets

Coronal slot Reduces distal stem stiffness and helps reduce thigh pain

Distal flutesImprove rotational stability

CONSENSUSORTHOPEDICS

18

UN

ISY

N H

IP S

YST

EM

Page 25: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

References1. Atwood, SA, Van Citters, DW, Patten, EW, Furmanski, J, Reis, MD, Pruitt, LA. Tradeoffs Amongst Fatigue, Wear, and Oxidation Resistance of Cross-linkedUltra-high Molecular Weight Polyethylene. Journal of the Mechanical Behavior of Biomedical Materials. 2011 March ; 4:1033-1045.2. U.S. patent 5,271,7373. U.S. patents 6,261,322, 6,652,588, 7,105,0304. U.S. patent 5,271,7375. Bosker BH, Verheyen CC, Horstmann WG, Tulp NJ, Poor accuracy of freehand cup positioning during total hip arthroplasty, Arch Orthop Trauma Surg(2007) 127, p. 375-3796. Hananouchi T, Saito M, Koyama T, Sugano N, Yoshikawa H, Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement, Clin OrthopRelat Res., 2010 Apr 468(4), p. 1088-10957. Phillips CB, Barrett JA, Losina E, et al., Incidence rates of dislocation, pulmonary embolism, and deep infection during the first six months after electivetotal hip replacement, J Bone Joint Surg Am. 2003 85, p. 20-268. Cooper RA, McAllister CM, Borden LS, Bauer TW., Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplasty: A cause oflate failure, J Arthroplasty. 1992 7.3, p. 285-2909. U.S. Patent Nos. 4,851,007; 5,876,459; 5,906,644; 5,725,592; 5,902,340

CONSENSUSORTHOPEDICS

19

Page 26: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,
Page 27: 1115 Windfield Way, Suite 100 Product Portfolio › wp-content › uploads › 2016 › ... · 2016-07-20 · 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100,

1115 Windfield Way, Suite 100El Dorado Hills, Ca 95762 916-355-7100, 916-355-7190 [email protected] consensusortho.com

1115 Windfield Way, Suite 100, El Dorado Hills, CA 95762P. 916-355-7100 | F. 916-355-7190 | [email protected] | www.consensusortho.com

98107-01B