7/30/2019 11058-09-0905!01!001 - Pressure Drop Calculation-Ambato Skid
1/10
Project:CONSTRUCCION DEL POLIDUCTO AMBATO-RIOBAMBA
Customer:PETROECUADOR
Customer P.O. No.:
Client Document Code.
Equipment Tag No.:EA-UM-120
PRESSURE DROP CALCULATIONAMBATO SKID (EA-UM-120)
Document Number: 11058-09-0905-01-001
Prepared: Anant Kumbhejkar Title: Mechanical Engineer Date: 20.10.11
Checked: Al ODowd Title: Engineering Manager Date: 20.10.11
Authorized: Juan Mello Title: Project Manager Date: 20.10.11
DANIEL
-
7/30/2019 11058-09-0905!01!001 - Pressure Drop Calculation-Ambato Skid
2/10
INDEX
1. SCOPE ----------------------------------------------------------------------------------------------------------------------------------------- 32. PROCESS ------------------------------------------------------------------------------------------------------------------------------------- 33. ASSUMPTIONS ------------------------------------------------------------------------------------------------------------------------------ 34. COMPONENT PRESSURE DROPS USED------------------------------------------------------------------------------------------- 45. SUMMARY ------------------------------------------------------------------------------------------------------------------------------------ 56. RESULTS & CONCLUSION -------------------------------------------------------------------------------------------------------------- 67. APPENDIX------------------------------------------------------------------------------------------------------------------------------------- 7
-
7/30/2019 11058-09-0905!01!001 - Pressure Drop Calculation-Ambato Skid
3/10
1. SCOPE
The pressure drop calculations are carried out for the Ambato metering skid to be supplied toCONSTRUCCION DEL POLIDUCTO AMBATO-RIOBAMBA PROJECT.
The system has 2 x 100 % (i.e. 1 streams operating + 1 standby stream) flow configuration. Each streamhas coriolis meter for measurement of flow. The system can be connected to compact prover also forproving purpose.
Based on below reference drawings, pressure drop is calculated considering the following metering cases
REFERENCE DRAWING NUMBERS: 11058-09-0910-01-400 (P&I Diagram)
11058-09-0910-01-001 (GA drawing)
2. PROCESS
PRODUCT DIESEL,EXTRA GASOLINE, PREMIUM GASOLINE
MINIMUM NORMAL MAXIMUM
STATION FLOW RATE (TOTAL) (GPM) 0 350 500
FLOW RATE (PER STREAM) (GPM) 0 350 500
OPERATING PRESSURE PSIg 20 80 740OPERATING TEMPERATURE - F 30.92 55.04 78.08
DESIGN PRESSURE PSIg 740
DESIGN TEMPERATURE - F ---
SPECIFIC GRAVITY 0.745 to 0.88
VISCOSITY (cSt) 0.94 to 8.97
* Pressure Drop calculations are carried out at normal operating pressure which is 80 PSIg & Maximum flowrate.
Pressure drop calculations are performed for the following cases:-
CASE A: Normal Metering
-
7/30/2019 11058-09-0905!01!001 - Pressure Drop Calculation-Ambato Skid
4/10
4. COMPONENT PRESSURE DROPS USED
These pressure drop values are obtained from information supplied by the manufacturer or from data booksand are incorporated into the pressure drop calculations attached.
Basket Strainer
P= 7 PSI @ max.flow of 500 GPM
Coriolis Meter
P= 8.6 PSI @ max.flow of 500 GPM
-
7/30/2019 11058-09-0905!01!001 - Pressure Drop Calculation-Ambato Skid
5/10
5. SUMMARY
The pressure drop calculations are performed using Design Flow Solution software version 4.19based on theassumptions, process data mentioned on page no.3. For the components not available in the softwaredatabase, values for Cv or direct pressure drop value in Bar collected from manufacturer and used forcalculations.
Following Formulae were used for calculation:-
-
7/30/2019 11058-09-0905!01!001 - Pressure Drop Calculation-Ambato Skid
6/10
6. RESULTS & CONCLUSION
CALCULATIONCASES
(Appendix )
PRESSURE DROPCALCULATION
CASES
FLOW(GPM) per
Stream
OUTLETPRESSURE
(PSIg)
TOTALPRESSURE
DROP(PSI)
CASE AMetering 500 41 39
Since calculated total pressure drop in last column of the above table is reasonable for Ambato liquid meteringsystem, Daniel feels the proposed piping arrangement with given components can be used without making anyalteration in design.
Also it is estimated that during proving pressure drop may go upto 49 PSI.
-
7/30/2019 11058-09-0905!01!001 - Pressure Drop Calculation-Ambato Skid
7/10
7. APPENDIX
Software output results for
CASE A
-
7/30/2019 11058-09-0905!01!001 - Pressure Drop Calculation-Ambato Skid
8/10
GATE
VALVE
PLUG
VALVE
PLUG
VALVE
CHECK
VALVE
CORIOLIS
METER
6"-300#
METERING
OUTLET
TOTAL PRESSURE DROP THROUGH THE SYSTEM DURING METERING IS = 80- 41 =39 PSI
GATE
VALVE STRAINER
STRAINERCORIOLIS
METER PLUGVALVE
CHECKVALVE
PLUG
VALVE
PLUG
VALVE
6"-300#
METERING
INLET
EA-UM-120
AMBATO METERING SYSTEM
80.0 80.080.0 76.8
73.0
73.1
77.2
77.2
73.0 72.072.0 71.671.6 64.664.6 63.963.9 55.355.3 53.153.1 51.851.8 50.950.9 50.650.6 48.248.2 48.148.1 47.2
47.2
47.0
49.9
49.9
43.4 42.9
45.8
45.8
45.8
41.7 41.641.6 40.740.7 40.740.7 40.4
43.3
43.3
43.3
39.2 41.041.0 41.0
77.2 77.277.2 49.949.9 49.949.9 49.949.9 49.949.9 49.9
Pressure in PSIG
DF DesigNet, Version 4 Tue Aug 23 17:01:26 2011...\PRESSURE DROP CALCULATIONS\REV.A\AMBATO SKID\AMBATO SKID.NET
-
7/30/2019 11058-09-0905!01!001 - Pressure Drop Calculation-Ambato Skid
9/10
GATE
VALVE
PLUG
VALVE
PLUG
VALVE
CHECK
VALVE
CORIOLIS
METER
6"-300#
METERING
OUTLET
TOTAL PRESSURE DROP THROUGH THE SYSTEM DURING METERING IS = 80- 41 =39 PSI
GATE
VALVE STRAINER
STRAINERCORIOLIS
METER PLUGVALVE
CHECKVALVE
PLUG
VALVE
PLUG
VALVE
6"-300#
METERING
INLET
EA-UM-120
AMBATO METERING SYSTEM
0.002854 3.21
0.16
0.00
0.94 0.39 7.01 0.67 8.62 2.25 1.30 0.87 0.33 2.42 0.08 0.86
0.16
0.00
0.44
0.00
0.08 0.87 0.08 0.25
0.00
-1.82 0.002854
0.00 0.00 -1.22 0.00 1.22 0.00 0.00 0.00 0.00 0.00
DP in PSID
DF DesigNet, Version 4 Tue Aug 23 17:01:26 2011...\PRESSURE DROP CALCULATIONS\REV.A\AMBATO SKID\AMBATO SKID.NET
-
7/30/2019 11058-09-0905!01!001 - Pressure Drop Calculation-Ambato Skid
10/10
GATE
VALVE
PLUG
VALVE
PLUG
VALVE
CHECK
VALVE
CORIOLIS
METER
6"-300#
METERING
OUTLET
TOTAL PRESSURE DROP THROUGH THE SYSTEM DURING METERING IS = 80- 41 =39 PSI
GATE
VALVE STRAINER
STRAINERCORIOLIS
METER PLUGVALVE
CHECKVALVE
PLUG
VALVE
PLUG
VALVE
6"-300#
METERING
INLET
EA-UM-120
AMBATO METERING SYSTEM
500.0 500.0
500.0
0.0
500.0 500.0 500.0 500.0 500.0 500.0 500.0 500.0 500.0 500.0 500.0 500.0
500.0
0.0
500.0
0.0
0.0
500.0 500.0 500.0 500.0
0.0
0.0
500.0 500.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Volumetric Flow Rate in US gal/min
DF DesigNet, Version 4 Tue Aug 23 17:01:26 2011...\PRESSURE DROP CALCULATIONS\REV.A\AMBATO SKID\AMBATO SKID.NET