11 - 12 Temperature

download 11 - 12 Temperature

of 2

Transcript of 11 - 12 Temperature

  • 7/30/2019 11 - 12 Temperature

    1/212950 W.Eight Mile Road Oak Park,MI 48237-3288248/399-8000 FAX:248/399-7246www.trerice.com

    1/1/200

    How to OrderSam ple O rder N um ber 435010207

    4350 1 02 07

    Model StemStyle StemLength Specific Range

    4350 51/2" Straight 1 Aluminum* 02 2" See Standard4352 51/2" 90Angle 9 Air-Duct 04 4" Available Ranges

    06 6" (over)12 12"

    *Use of thermowell required (must be ordered separately).

    5 1/2" Scale

    One ScaleDivision

    Accuracy

    CastAluminumCase

    Rigid Straightor Rigid 90Angle Case

    Optional features are also available.Pleaseconsult the Options Section for details.

    ______________________________________

    Trerice Econo Thermometers (air-duct stemexcluded) have no external mountinghardware,and as such,require the use of athermowell, which is attached to the stem viaa set screw.The thermowell must be ordered

    separately please consult the ThermowellSection of this catalog.

    4352 pictured

    The Trerice Econo Thermometer provides

    accuracy and durability at an economicalprice. This mercury-in-glass thermometer

    has a durable cast aluminum case and apolycarbonate frame front and window.Rigid straight and rigid 90angle cases

    are available.

    SpecificationsModels4350 (Rigid Straight)

    4352 (Rigid 90Angle)

    Scale Size

    5 1/2"

    CaseCast aluminum, blue epoxyfinished

    StemAluminum or air-duct styleavailable

    Connection

    Use of thermowell required(must be ordered separately)

    Air-duct stem has mountingflange with 3 bolt holes

    WindowPolycarbonate frame front

    TubeLens front, red appearing

    mercury

    ScaleAluminum, white backgroundwith black graduations andmarkings

    Accuracy1 scale division

    Approximate ShippingWeight

    0.5 lbs [0.23 kg]

    Aluminum Stem]Air-Duct Stem]

    Econo Thermometer

  • 7/30/2019 11 - 12 Temperature

    2/212950 W.Eight Mile Road Oak Park,MI 48237-3288248/399-8000 FAX:248/399-7246www.trerice.com

    1/1/2001

    2

    Econo Thermometer

    A ll dimensions are nominal.

    Dimensions in [ ] are in millimeters.

    Standard Available RangesFahrenheit Ranges Celsius Ranges Dual Scale Ranges Fahrenheit Celsius

    Range Range Range Range Range Range Figure Minor Figure MinorCode Code Code Intervals Divisions Intervals Divisions

    01 40 to 110F 17 40 to 40C 41 40 to 110F & 40 to 40C 20 2 10 1

    03 30 to 130F 25 0 to 55C 43 30 to 130F & 0 to 55C 10 1 10 1

    06 30 to 180F 27 0 to 82C 46 30 to 180F & 0 to 82C 20 2 10 1

    07 30 to 240F 19 0 to 115C 47 30 to 240F & 0 to 115C 20 2 10 1

    08 30 to 300F 20 0 to 150C 48 30 to 300F & 0 to 150C 30 5 10 2

    09 50 to 400F 28 10 to 205C 49 50 to 400F & 10 to 205C 50 5 20 2

    13 200 to 500F 32 93 to 260C 53 200 to 500F & 93 to 260C 25 5 10 2

    StemLength U

    2" (Aluminum) 1.31 [33.3]

    4" (Aluminum) 3.25 [82.6]

    6" (Air-Duct) 6.00 [152.4]

    12" (Air-Duct) 12.00 [304.8]Note: Shown with required thermowell(must be ordered separately)

    AIR-DUCT STEMMOUNTING DIMENSIONS

    AIR-DUCT STEM

    .25 - 3 HOLESEQUALLYSPACED

    2.50[64]

    1.50[38]

    U DIM.

    .50[13]

    .88 [22]HEX

    1.42[36]

    U

    U

    .82[21]

    1.33[34]

    6.69[170]

    1.62[41]

    .53[14]