10611 Partiwall Steel Stud_V2

3
BORAL PLASTERBOARD | June 2012 For installation details contact TecASSIST ® 1800 811 222 Partiwall ® Systems FRL 60/60/60 (System Type 25SP) (Insulation not shown for clarity) 25SP1010A - 1x25mm Shaftliner panel - 1x10mm Soundstop® plasterboard to each side of steel frame 237 76 36.9 60/60/60 FCO-2256 60 47 R2.0 glass wool or 100P14 both sides - 237 76 62 50 90G32 both sides 5.9 269 76 or 92 59 48 115mm thick R2.5 glass wool ceiling batt one side only - 269 76 or 92 63 53 115mm thick R2.5 glass wool ceiling batt both sides 5.3 289 92 62 50 R2.0 glass wool or 100P14 both sides 4.8 or 5.0 299 92 65 55 115mm thick R2.5 glass wool ceiling batt both sides 5.8 (Insulation not shown for clarity) 25SP1313A - 1x25mm Shaftliner panel - 1x13mm ENVIRO Soundstop® plasterboard to each side of steel frame 243 76 42.9 60/60/60 FCO-2256 61 49 R2.0 glass wool or 100P14 both sides - 243 76 62 50 90G16 both sides 5.3 275 76 or 92 62 50 R2.0 glass wool both sides 4.8 100P14 both sides 4.9 275 76 or 92 57 44 85P9 both sides - 285 92 65 55 115mm thick R2.5 glass wool ceiling batt both sides 5.3 (Insulation not shown for clarity) 25SP2020 - 1x25mm Shaftliner panel - 2x10mm Regular plasterboard to each side of steel frame 257 76 47.7 60/60/60 FCO-2256 64 50 R2.0 glass wool or 100P14 both sides 4.6 or 4.4 289 76 or 92 65 51 R1.5 glass wool both sides 3.7 70P14 both sides 3.9 299 92 67 56 115mm thick R2.5 glass wool ceiling batt both sides 5.6 - For explanation of System Reference notation refer Section B1 of Boral Selector+ Plasterboard Systems. - Insulation abbreviation: XXGYY = Glasswool insulation in format of thickness (mm), G (Glasswool), Density (kg/m 3 ). XXPYY = Polyester insulation in format of thickness (mm), P (Polyester), Density (kg/m 3 ). - Where two stud sizes are nominated for a particular wall width, the gap from the stud to the Shaftliner fire barrier: - provides a maximum allowable gap of 40mm for the 76mm stud or - meets the BCA requirement of a 20mm gap for the 92mm stud. - The above Thermal calculations are based on insulation path only. Refer to James M Fricker Report i274b. Assembly System Reference Nom Width (mm) Stud Size (mm) Pbd Weight (kg/m 2 ) Fire Acoustic Ratings Total R Value (m 2 K/W) FRL Basis R w R w +C tr Insulation

description

Light Commercial Construction Professional

Transcript of 10611 Partiwall Steel Stud_V2

Page 1: 10611 Partiwall Steel Stud_V2

BORAL PLASTERBOARD | June 2012 For installation details contact TecASSIST® 1800 811 222

Partiwall® SystemsFRL 60/60/60 (System Type 25SP)

(Insulation not shown for clarity)

25SP1010A

- 1x25mm Shaftliner™ panel- 1x10mm Soundstop® plasterboard to

each side of steel frame

237 76 36.9 60/60/60FCO-2256

60 47 R2.0 glass wool or 100P14 both sides

-

237 76 62 50 90G32both sides

5.9

269 76 or 92 59 48 115mm thick R2.5 glass wool ceiling batt one side only

-

269 76 or 92 63 53 115mm thick R2.5 glass wool ceiling batt both sides

5.3

289 92 62 50 R2.0 glass wool or 100P14 both sides

4.8 or

5.0

299 92 65 55 115mm thick R2.5 glass wool ceiling batt both sides

5.8

(Insulation not shown for clarity)

25SP1313A

- 1x25mm Shaftliner™ panel- 1x13mm ENVIRO Soundstop®

plasterboard to each side of steel frame

243 76 42.9 60/60/60FCO-2256

61 49 R2.0 glass wool or 100P14 both sides

-

243 76 62 50 90G16both sides

5.3

275 76 or 92 62 50 R2.0 glass wool both sides

4.8

100P14 both sides 4.9

275 76 or 92 57 44 85P9 both sides -

285 92 65 55 115mm thick R2.5 glass wool ceiling batt both sides

5.3

(Insulation not shown for clarity)

25SP2020

- 1x25mm Shaftliner™ panel- 2x10mm Regular plasterboard to

each side of steel frame

257 76 47.7 60/60/60FCO-2256

64 50 R2.0 glass wool or 100P14both sides

4.6 or 4.4

289 76 or 92 65 51 R1.5 glass wool both sides

3.7

70P14 both sides 3.9

299 92 67 56 115mm thick R2.5 glass wool ceiling batt both sides

5.6

- For explanation of System Reference notation refer Section B1 of Boral Selector+ Plasterboard Systems.- Insulation abbreviation: XXGYY = Glasswool insulation in format of thickness (mm), G (Glasswool), Density (kg/m3). XXPYY = Polyester insulation in format of thickness (mm), P (Polyester), Density (kg/m3).- Where two stud sizes are nominated for a particular wall width, the gap from the stud to the Shaftliner fire barrier: - provides a maximum allowable gap of 40mm for the 76mm stud or - meets the BCA requirement of a 20mm gap for the 92mm stud.- The above Thermal calculations are based on insulation path only. Refer to James M Fricker Report i274b.

AssemblySystem Reference

Nom Width(mm)

Stud Size(mm)

Pbd Weight (kg/m2)

Fire Acoustic Ratings Total R Value(m2K/W)

FRL Basis Rw Rw+Ctr Insulation

Page 2: 10611 Partiwall Steel Stud_V2

For installation details contact TecASSIST® 1800 811 222 June 2012 | BORAL PLASTERBOARD

» Partiwall® SystemsFRL 90/90/90 (System Type 41SP)

(Insulation not shown for clarity)

41SP1010

- 1x16mm Firestop® plasterboard laminated on one side to 1x25mm Shaftliner™ panel

- 1x10mm Regular plasterboard to each side of steel frame

285 76 or 92 47.1 90/90/90FCO-2713

63 50 R2.0 glass wool or 100P14both sides

4.9 or

5.0

285 76 or 92 64 52 115mm thick R2.5 glass wool ceiling batt both sides

-

305 92 67 55 115mm thick R2.5 glass wool ceiling batt both sides

5.4

(Insulation not shown for clarity)

41SP1010A

- 1x16mm Firestop® plasterboard laminated on one side to 1x25mm Shaftliner™ panel

- 1x10mm Soundstop® plasterboard to each side of steel frame

253 76 49.9 90/90/90FCO-2713

60 49 R2.0 glass wool or 100P14one side only

-

253 76 63 51 R2.0 glass wool or 100P14both sides

4.6 or 4.7

285 76 or 92 61 50 R2.0 glass wool or 100P14one side only

2.9 or

2.9

285 76 or 92 66 54 R2.0 glass wool or 100P14both sides

-

285 76 or 92 67 55 115mm thick R2.5 glass wool ceiling batt both sides

5.4

(Insulation not shown for clarity)

41SP1313A

- 1x16mm Firestop® plasterboard laminated on one side to 1x25mm Shaftliner™ panel

- 1x13mm ENVIRO Soundstop® plasterboard to each side of steel frame

259 76 55.9 90/90/90FCO-2713

62 50 R2.0 glass wool or 100P14one side only

-

259 76 64 52 R2.0 glass wool or 100P14both sides

4.6 or 4.7

291 76 or 92 62 51 R2.0 glass wool or 100P14one side only

2.9 or

2.9

291 76 or 92 67 55 R2.0 glass wool or 100P14both sides

4.9 or

5.0

- For explanation of System Reference notation refer Section B1 of Boral Selector+ Plasterboard Systems.- Insulation abbreviation: XXGYY = Glasswool insulation in format of thickness (mm), G (Glasswool), Density (kg/m3). XXPYY = Polyester insulation in format of thickness (mm), P (Polyester), Density (kg/m3).- Where two stud sizes are nominated for a particular wall width, the gap from the stud to the Shaftliner fire barrier: - provides a maximum allowable gap of 40mm for the 76mm stud or - meets the BCA requirement of a 20mm gap for the 92mm stud.- The above Thermal calculations are based on insulation path only. Refer to James M Fricker Report i274b.

AssemblySystem Reference

Nom Width(mm)

Stud Size(mm)

Pbd Weight (kg/m2)

Fire Acoustic Ratings Total R Value(m2K/W)

FRL Basis Rw Rw+Ctr Insulation

Page 3: 10611 Partiwall Steel Stud_V2

BORAL PLASTERBOARD | June 2012 For installation details contact TecASSIST® 1800 811 222

(Insulation not shown for clarity)

50SP1010

- 2x25mm Shaftliner™ panel- 1x10mm Regular plasterboard to

each side of steel frame

262 76 54.6 90/90/90FCO-1446FCO-2016FCO-2256

61 48 R2.0 glass wool or 100P14both sides

-

294 76 or 92 64 51 R2.0 glass wool or 100P14both sides

4.9 or

5.0

304 92 67 55 115mm thick R2.5 glass wool ceiling batt both sides

5.6

(Insulation not shown for clarity)

50SP1010A

- 2x25mm Shaftliner™ panel- 1x10mm Soundstop® plasterboard to

each side of steel frame

262 76 57.4 90/90/90Cf NA

FCO-1446FCO-2016FCO-2256

60 48 R2.0 glass wool or 100P14one side only

-

262 76 63 51 R2.0 glass wool or 100P14both sides

4.6 or

4.2

294 76 or 92 62 50 R2.0 glass wool or 100P14one side only

-

294 76 or 92 67 55 R2.0 glass wool or 100P14both sides

4.9 or

5.0

(Insulation not shown for clarity)

50SP1313A

- 2x25mm Shaftliner™ panel- 1x13mm ENVIRO Soundstop®

plasterboard to each side of steel frame

268 76 63.4 90/90/90FCO-1446FCO-2016FCO-2256

62 50 R2.0 glass wool or 100P14one side only

-

268 76 65 53 R2.0 glass wool or 100P14both sides

4.6 or

4.3

300 76 or 92 63 52 R2.0 glass wool or 100P14one side only

-

300 76 or 92 68 56 R2.0 glass wool or 100P14both sides

5.0 or

5.0

- For explanation of System Reference notation refer Section B1 of Boral Selector+ Plasterboard Systems.- Insulation abbreviation: XXGYY = Glasswool insulation in format of thickness (mm), G (Glasswool), Density (kg/m3). XXPYY = Polyester insulation in format of thickness (mm), P (Polyester), Density (kg/m3).- Where two stud sizes are nominated for a particular wall width, the gap from the stud to the Shaftliner fire barrier: - provides a maximum allowable gap of 40mm for the 76mm stud or - meets the BCA requirement of a 20mm gap for the 92mm stud.- The above Thermal calculations are based on insulation path only. Refer to James M Fricker Report i274b.

» Partiwall® SystemsFRL 90/90/90 (System Type 50SP)

AssemblySystem Reference

Nom Width(mm)

Stud Size(mm)

Pbd Weight (kg/m2)

Fire Acoustic Ratings Total R Value(m2K/W)

FRL Basis Rw Rw+Ctr Insulation

BCC

1061

1 Ju

n12