Developing near real-time DEP hardware

Nahrizul Adib [email protected]

Page 2: 100428 ug2

2:18

What’s DEP?

• Electrophoresis– Charged particles moving in uniform field

D ie lec tric pa rtic le

Page 3: 100428 ug2

3:18

What’s DEP?

• Dielectrophoresis– Dielectric particles moving in non-uniform field

Dielectric particle

Die lectric particle

Positive DEP Negative DEP

Page 4: 100428 ug2

4:18

What’s DEP?

• Theory bit– (the only time an equation appears in this

presentation… promise!)

232F E)K(Rer m

**

**

2)(

mp

mpK

j

*

Page 5: 100428 ug2

5:18

What’s DEP used for?

• Cell movement can be manipulated by frequency changes, so DEP is good for cell collection and sorting

Morgan et al. Biophysical Journal 77 (1999) 516-525

Page 6: 100428 ug2

6:18

What’s DEP used for?

• Compare cell viability

G.H. Markx, C.L. Davey / Enzyme and Microbial Technology 25 (1999) 161–171

Page 7: 100428 ug2

7:18

What’s DEP used for?

• Compare effects of chemicals on cells

F.H. Labeed et al. / Biochimica et Biophysica Acta 1760 (2006) 922–929

Page 8: 100428 ug2

8:18

What’s DEP used for?

• Predict cell properties

232F E)K(Rer m

Page 9: 100428 ug2

9:18

What’s DEP used for?

• Everything’s fine and dandy BUT DEP is not available commercially, nor used widely– Despite being described back in 1950s

• …but why?– Small assays only

• Restricted to research use

– Time consuming• One spectrum takes 40-60 minutes

Page 10: 100428 ug2

10:18

What’s DEP used for?

• The answer(?): Multiple experiments at the same time!– Different

frequencies, or– Same frequencies

10kHz 2MHz

300um

Page 11: 100428 ug2

11:18

http://www.youtube.com/watch?v=lLZbr3vP-Zs

Page 12: 100428 ug2

12:18

DEP: The setup

• What’s needed:

Imaging/recording device

Microscope

Electrode

Cells

Signal generator

Page 13: 100428 ug2

13:18

DEP: The (new) setup

• What’s (really) needed:

Imaging/recording device

Microscope

Electrode

Cells

Multiple output signal generator

Page 14: 100428 ug2

14:18

Real-time DEP

Page 15: 100428 ug2

15:18

Real-time DEP

103

104

105

106

107

108

-1

-0.8

-0.6

-0.4

-0.2

0

0.2

0.4

0.6

0.8

1

Frequency (Hz)

Nor

mal

ised

ligh

t in

tens

ity

DEP plots for Jurkat cells treated with valinomycin 100402 (10 mS/m)

Control

Valinomycin

Page 16: 100428 ug2

16:18

Real-time DEP

105

106

05

1015

20

25-1

0

1

2

3

4

5

Frequency (Hz)

DEP spectrum for Jurkat cells treated with valinomycin 091216