100% CDS - F.T. James

11
AEED, Advanced Energy Engineering & Design, Inc CHATTANOOGA, TN 37405 BUS. (423) 752-3438 FAX (423) 752-1369 P.O. BOX 4934 408 McCALLIE AVE inc. AEED JOB NO. 029-15 COPYRIGHT NOTICE THE DRAWINGS ARE THE PROPERTY OF RIVER STREET ARCHITECTURE LLC. ANY USE, REUSE, REPRODUCTION, DISPLAY OR SALE OF THESE DRAWINGS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT IS STRICTLY PROHIBITED. 714 cherry street, chattanooga, tennessee 37402 p.423 634 0806 f.423 752 8499 www.river-st-architecture.com Release Date: Project No.: 3/31/2015 10:17:24 AM 12055 GATEWAY WEST BLVD, EL PASO , TX COURTYARD BY MARRIOTT ZARAGOZA HOTEL PARTNERS, LLC MECHANICAL M0.1 COVER SHEET S R M0.1 MECHANICAL COVER SHEET M1.2 6/25/2016 100% CDS x x MECHANICAL SHEET INDEX ISSUE LOG TITLE # DATE HVAC GENERAL NOTES 1. THESE GENERAL NOTES APPLY TO ALL MECHANICAL DRAWINGS. IN THE EVENT THAT ANY GENERAL NOTE CONFLICTS WITH THE WRITTEN CONSTRUCTION SPECIFICATIONS, THE 2. CONTRACTOR SHALL PROVIDE ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO INSTALL A COMPLETE AND OPERABLE MECHANICAL SYSTEM AS INDICATED ON THE DRAWINGS, SPECIFICATIONS AND IN ACCORDANCE WITH APPLICABLE CODES. 3. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS. THE CONTRACTOR SHALL PROVIDE ALL HANGERS AND SUPPORTS (IN COMPLIANCE WITH SEISMIC CATEGORY “C”) REQUIRED FOR A COMPLETE INSTALLATION. 4. THE MECHANICAL DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. DO NOTE SCALE DRAWINGS. 5. COORDINATE ALL MECHANICAL WORK WITH OTHER TRADES TO INSURE PROPER CLEARANCE AND SPATIAL RELATIONSHIPS TO OTHER EQUIPMENT AND STRUCTURAL COMPONENTS. 6. COORDINATE ALL EQUIPMENT CONNECTIONS WITH MANUFACTURER'S CERTIFIED DRAWINGS. COORDINATE AND PROVIDE ALL DUCT AND PIPE TRANSITIONS REQUIRED FOR FINAL CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY ALL DUCT AND PIPE DIMENSIONS PRIOR TO FABRICATION. 8. PROVIDE FLEXIBLE DUCT AND PIPE CONNECTIONS TO ALL MECHANICAL EQUIPMENT. 9. ALL CONTROL WIRING AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE. ALL CONTROL WIRING IN RETURN PLENUMS SHALL BE PLENUM RATED. CONTROL WIRING LOCATED IN MECHANICAL ROOMS SHALL BE ROUTED IN RIGID CONDUIT. 10. CONTRACTOR IS RESPONSIBLE FOR THE RESTART OF ANY SYSTEMS DE-ENERGIZED TO ACCOMMODATE THIS WORK. 12. PROVIDE AND INSTALL ACCESS PANELS/DOORS IN WALLS, CEILINGS AND DUCTWORK AS REQUIRED TO ACCESS/SERVICE VALVES, DUCT DETECTORS, CONTROL COMPONENTS, FIRE DAMPERS AND OTHER CONCEALED MECHANICAL DEVISES. 13. ALL DUCT DIMENSIONS ARE INSIDE CLEAR UNLESS OTHERWISE NOTED. ALL DUCT DIMENSIONS SHALL BE MODIFIED AS REQUIRED TO ACCOUNT FOR DUCT INSULATION. 14. LOCATE ALL MECHANICAL EQUIPMENT TO FACILITATE UNOBSTRUCTED AIR/WATER FLOW AND ACCESS TO UNIT SERVICE PANELS, CONTROLS AND VALVES AS REQUIRED BY THE MANUFACTURER AND APPLICABLE CODES. 15. ALL AIR/HYDRONIC LEAK TESTING AND INSPECTIONS SHALL BE COMPLETED PRIOR TO THE APPLICATION OF INSULATING MATERIALS. FAILURE TO COMPLY WITH THIS REQUIREMENT MAY RESULT IN THE REMOVAL AND REAPPLICATION OF THE INSULATION AT THE CONTRACTORS EXPENSE. 16. LOCATE ALL TEMPERATURE, PRESSURE, FLOW MEASURING DEVICES AND COMPONENTS IN ACCESSIBLE LOCATIONS WITH STRAIGHT SECTIONS OF PIPE/DUCTWORK UP AND DOWN STREAM OF DEVICE AS OUTLINED BY THE EQUIPMENT MANUFACTURER. 17. TESTING, ADJUSTING AND BALANCING CONTRACTOR SHALL BE A CURRENT AND RECOGNIZED MEMBER OF THE AABC OR NEBB AS OUTLINED IN THE CONSTRUCTION SPECIFICATIONS. 18. ALL DUCTWORK, PIPING OR EQUIPMENT SUPPORTED FROM THE STRUCTURE SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR. CONTRACTOR RESPONSIBLE FOR THE REPAIR/REPLACEMENT OF ANY FIREPROOFING REMOVED TO ACCOMMODATE HANGER ATTACHMENT. 19. ALL NEW/MODIFIED SUPPLY DUCTWORK SHALL BE EXTERNAL INSULATED IN ACCORDANCE WITH THE CONSTRUCTION SPECIFICATIONS. 20. CONFIRM LOCATIONS OF FIRE RATED CEILINGS, WALLS AND FLOORS. FIRE SEAL ALL PENETRATIONS WITH FIRE STOP SEALANT. DUCTWORK THAT PENETRATES FIRE PARTITIONS SHALL BE EQUIPPED WITH FIRE DAMPERS. 21. OFFSET DUCTWORK AS REQUIRED TO ACCOMMODATE THE ARCHITECTURAL REFLECTIVE CEILING PLAN. 22. NO SUPPLY DIFFUSER SHALL BE LOCATED WITHIN 36” OF ANY SMOKE DETECTOR OR AUTOMATIC SPRINKLER HEAD/DEVICE. 23. ALL 45 DEGREE OR GREATER ELBOWS (INCLUDING THOSE AT DIFFUSER CONNECTIONS) SHALL BE CONSTRUCTED OF RIGID DUCTWORK. 24. ALL WORK SHALL BE PREFORMED IN ACCORDANCE WITH SITE CONSTRUCTION AND SAFETY REQUIREMENTS. NO WORK SHALL BE PERFORMED WITHOUT A VALID JOB SCHEDULE AND FIRE ALARM PERMITS (WHERE REQUIRED). ALL WORKERS MUST REGISTER WITH THE LOCAL MAINTENANCE CONTRACTOR PRIOR TO PERFORMING ANY WORK. 25. ALL WASTE OR DISCARDED MATERIALS SHALL BE RECYCLED IN ACCORDANCE WITH SITE CONSTRUCTION POLICIES. REPORT ALL RECYCLED MATERIAL QUANTITIES TO PROJECT ENGINEER. WRITTEN REPORT SHALL INCLUDE MATERIAL TYPE, QUANTITIES, AND DISPOSITION OF THE MATERIALS. 26. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE SET OF AS-BUILT DRAWINGS DETAILING ALL FIELD MODIFICATIONS TO THE DESIGN DRAWINGS. DRAWINGS SHALL INCLUDE LOCATION AND ELEVATION REFERENCED FROM FINISHED FLOOR. MOST STRINGENT OF THE TWO SHALL RULE. 11. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLING OVER 2000 CFM, MOUNTED IN SA DUCT (NFPA 90A, 4-4.2), AND IN RA DUCT PRIOR TO EXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNIT SERVING BUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S) TO STOP UNIT FAN IF SMOKE IS DETECTED. INTERLOCK WITH FIRE ALARM SYSTEM IF APPLICABLE. DIFFUSER TYPE DESIGNATION AIR QUANTITY NOTE: RUNOUT SIZE TO DIFFUSER IS THE SAME SIZE AS THE ROUND NECK NOTED OTHERWISE. DIFFUSER NECK UNLESS 2410 360 CFM B FIRE DAMPER FD DUCTWORK DUCTWORK - AIR TERMINALS DUCTWORK - EQUIPMENT SMOKE DAMPER SD COMBINATION FIRE & SMOKE DAMPER FSD M SMOKE DETECTOR SDT EQUIPMENT - HVAC EDH-x ELECTRIC DUCT HEATER, WITH TAG HVAC- AIR DISTRIBUTION TAG AC AIR CONDITIONING UNIT AD ACCESS DOOR AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT AMB AMBIENT AP ACCESS PANEL AS AIR STREAM ATM ATMOSPHERE BD BALANCING DAMPER BDD BACK DRAFT DAMPER BHP BRAKE HORSEPOWER BLDG BUILDING BOD BOTTOM OF DUCT BTU BRITISH THERMAL UNIT BTUH BTU PER HOUR CC COOLING COIL CF CUBIC FEET CFM CUBIC FEET PER MINUTE CLG CEILING ABBREVIATIONS CU, HP-x CU, HP-x DIFFUSER SIZE EXAMPLE: 24x24 DIFFUSER WITH A 10"�NECK. VARIABLE AIR VOLUME BOX WITH TAG, DUCT SHOWN ROOF/CURB MOUNTED AIR HANDLING UNIT, DUCT NOT SHOWN INDOOR HORIZONTAL AIR HANDLING EQUIP, DUCT SHOWN INDOOR VERTICAL AIR HANDLING EQUIP, DUCT NOT SHOWN ROOF/CURB MOUNTED EXHAUST FAN WITH TAG, DUCT SHOWN INLINE SUSPENDED MOUNT EXHAUST FAN WITH TAG, DUCT SHOWN EF-x CEILING MOUNTED EXHAUST FAN WITH TAG, DUCT SHOWN CONDENSING UNIT ON EQUIPMENT RAILS WITH TAG CONDENSING UNIT ON CONCRETE HOUSE KEEPING PAD WITH TAG SIDEWALL GRILLE TAP WITH MANUAL VOLUME DAMPER, SQ 24x24 24" SIDEWALL GRILLE TAP WITH MANUAL VOLUME DAMPER, RND MOTORIZED DAMPER EXHAUST AIR GRILLE; EXHAUST DUCT AND MVD IN SECTION RETURN AIR GRILLE; RETURN DUCT AND MVD IN SECTION SUPPLY AIR DIFFUSER; SUPPLY DUCT AND MVD IN SECTION MVD; MANUAL BALANCING/VOLUME DAMPER HVAC LEGEND FPS FEET PER SECOND FS FLOW SWITCH FSD COMB SMOKE FIRE DAMPER FT FOOT OR FEET G GAS GAL GALLONS GALV GALVANIZED GPM GALLONS PER MINUTE HP HORSEPOWER HR HOUR HT HEIGHT HX HEAT EXCHANGER Hz FREQUENCY ID INSIDE DIAMETER IN INCH kW KILOWATT kWh KILOWATT HOUR L LENGTH LAT LEAVING AIR TEMPERATURE PSFG POUNDS PER SQUARE FOOT PSIG POUNDS PER SQUARE INCH QTY QUANTITY R RADIUS RA RETURN AIR REQ'D REQUIRED RF RETURN FAN RH HUMIDITY, RELATIVE RLA RUNNING LOAD AMPS RM ROOM SA SUPPLY AIR SD SMOKE DAMPER SF SUPPLY FAN SG SPECIFIC GRAVITY SH SENSIBLE HEAT SHR SENSIBLE HEAT RATIO SP STATIC PRESSURE SPEC SPECIFICATIONS SQ SQUARE MECHANICAL SPECIFICATIONS EQUIPMENT INSTALLATION - COMMON REQUIREMENTS 1. INSTALL EQUIPMENT LEVEL AND PLUMB, PARALLEL AND PERPENDICULAR TO OTHER BUILDING SYSTEMS AND COMPONENTS IN EXPOSED INTERIOR SPACES, UNLESS OTHERWISE INDICATED. 2. INSTALL HVAC EQUIPMENT TO FACILITATE SERVICE, MAINTENANCE, AND REPAIR OR REPLACEMENT OF COMPONENTS. CONNECT EQUIPMENT FOR EASE OF DISCONNECTING, WITH MINIMUM INTERFERENCE TO OTHER INSTALLATIONS. EXTEND GREASE FITTINGS TO ACCESSIBLE LOCATIONS. 3. INSTALL EQUIPMENT TO ALLOW RIGHT OF WAY FOR PIPING INSTALLED AT REQUIRED SLOPE. 4. DAMAGE AND TOUCHUP: REPAIR MARRED AND DAMAGED FACTORY-PAINTED FINISHES WITH MATERIALS AND PROCEDURES TO MATCH ORIGINAL FACTORY FINISH. DUCT HANGER AND SUPPORT INSTALLATION 1. COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE," CHAPTER 4, "HANGERS AND SUPPORTS." 2. HANGER SPACING: COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE," TABLE 4-1, "RECTANGULAR DUCT HANGERS MINIMUM SIZE," AND TABLE 4-2, "MINIMUM HANGER SIZES FOR ROUND DUCT," FOR MAXIMUM HANGER SPACING; INSTALL HANGERS AND SUPPORTS WITHIN 24 INCHES OF EACH ELBOW AND WITHIN 48 INCHES OF EACH BRANCH INTERSECTION. 3. HANGERS EXPOSED TO VIEW: THREADED ROD AND ANGLE OR CHANNEL SUPPORTS. 4. SUPPORT VERTICAL DUCTS WITH STEEL ANGLES OR CHANNEL SECURED TO THE SIDES OF THE DUCT WITH WELDS, BOLTS, SHEET METAL SCREWS, OR BLIND RIVETS; SUPPORT AT EACH FLOOR AND AT A MAXIMUM INTERVALS OF 16 FEET. 5. INSTALL UPPER ATTACHMENTS TO STRUCTURES. SELECT AND SIZE UPPER ATTACHMENTS WITH PULL-OUT, TENSION, AND SHEAR CAPACITIES APPROPRIATE FOR SUPPORTED LOADS AND BUILDING MATERIALS WHERE USED. DUCT INSTALLATION 1. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT OF DUCT SYSTEM. INDICATED DUCT LOCATIONS, CONFIGURATIONS, AND ARRANGEMENTS WERE USED TO SIZE DUCTS AND CALCULATE FRICTION LOSS FOR AIR-HANDLING EQUIPMENT SIZING AND FOR OTHER DESIGN CONSIDERATIONS. INSTALL DUCT SYSTEMS AS INDICATED UNLESS DEVIATIONS TO LAYOUT ARE APPROVED ON SHOP DRAWINGS AND COORDINATION DRAWINGS. 2. INSTALL DUCTS ACCORDING TO SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE" UNLESS OTHERWISE INDICATED. 3. INSTALL DUCTS WITH FEWEST POSSIBLE JOINTS. 4. INSTALL FACTORY- OR SHOP-FABRICATED FITTINGS FOR CHANGES IN DIRECTION, SIZE, AND SHAPE AND FOR BRANCH CONNECTIONS. 5. UNLESS OTHERWISE INDICATED, INSTALL DUCTS VERTICALLY AND HORIZONTALLY, AND PARALLEL AND PERPENDICULAR TO BUILDING LINES. 6. INSTALL DUCTS CLOSE TO WALLS, OVERHEAD CONSTRUCTION, COLUMNS, AND OTHER STRUCTURAL AND PERMANENT ENCLOSURE ELEMENTS OF BUILDING. 7. INSTALL DUCTS WITH A CLEARANCE OF 1 INCH, PLUS ALLOWANCE FOR INSULATION THICKNESS. 8. ROUTE DUCTS TO AVOID PASSING THROUGH TRANSFORMER VAULTS AND ELECTRICAL EQUIPMENT ROOMS AND ENCLOSURES. 9. WHERE DUCTS PASS THROUGH FIRE-RATED INTERIOR PARTITIONS AND EXTERIOR WALLS, INSTALL FIRE DAMPERS. 10. PROTECT DUCT INTERIORS FROM MOISTURE, CONSTRUCTION DEBRIS AND DUST, AND OTHER FOREIGN MATERIALS 11. PROTECT EXPOSED DUCTS FROM BEING DENTED, SCRATCHED, OR DAMAGED. 12. TRIM DUCT SEALANTS FLUSH WITH METAL. CREATE A SMOOTH AND UNIFORM EXPOSED BEAD. DO NOT USE TWO-PART TAPE SEALING SYSTEM. 13. GRIND WELDS TO PROVIDE SMOOTH SURFACE FREE OF BURRS, SHARP EDGES, AND WELD SPLATTER. WHEN WELDING STAINLESS STEEL WITH A NO. 3 OR 4 FINISH, GRIND THE WELDS FLUSH, POLISH THE EXPOSED WELDS, AND TREAT THE WELDS TO REMOVE DISCOLORATION CAUSED BY WELDING. 14. MAINTAIN CONSISTENCY, SYMMETRY, AND UNIFORMITY IN THE ARRANGEMENT AND FABRICATION OF FITTINGS, HANGERS AND SUPPORTS, DUCT ACCESSORIES, AND AIR OUTLETS. 15. REPAIR OR REPLACE DAMAGED SECTIONS AND FINISHED WORK THAT DOES NOT COMPLY WITH THESE REQUIREMENTS. 16. SEAL DUCTS TO THE FOLLOWING SEAL CLASSES ACCORDING TO SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE": COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE." OUTDOOR, SUPPLY-AIR DUCTS: SEAL CLASS A. OUTDOOR, EXHAUST DUCTS: SEAL CLASS C. OUTDOOR, RETURN-AIR DUCTS: SEAL CLASS C. UNCONDITIONED SPACE, SUPPLY-AIR DUCTS IN PRESSURE CLASSES 2-INCH WG AND LOWER: SEAL CLASS B. UNCONDITIONED SPACE, SUPPLY-AIR DUCTS IN PRESSURE CLASSES HIGHER THAN 2-INCH WG: SEAL CLASS A. UNCONDITIONED SPACE, EXHAUST DUCTS: SEAL CLASS C. UNCONDITIONED SPACE, RETURN-AIR DUCTS: SEAL CLASS B. CONDITIONED SPACE, SUPPLY-AIR DUCTS IN PRESSURE CLASSES 2-INCH WG AND LOWER: SEAL CLASS C. CONDITIONED SPACE, SUPPLY-AIR DUCTS IN PRESSURE CLASSES HIGHER THAN 2-INCH WG: SEAL CLASS B. CONDITIONED SPACE, EXHAUST DUCTS: SEAL CLASS B. CONDITIONED SPACE, RETURN-AIR DUCTS: SEAL CLASS C. 17. THE INSTALLATION OF ALL INSULATION SHALL BE PERFORMED BY AN EXPERIENCED CRAFTSMAN IN A NEAT WORKMANSHIP-LIKE MANNER AND SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN PUBLISHED RECOMMENDATIONS FOR SERVICE INTENDED. 18. CONCEALED INDOOR SUPPLY, RETURN & OUTDOOR AIR DUCTS SHALL BE INSULATED WITH A MINERAL-FIBER BLANKET, 2 INCHES THICK, 1.5-LB/CU. FT. NOMINAL DENSITY. 19. EXPOSED INDOOR SUPPLY & RETURN DUCTS SHALL BE DOUBLE WALL DUCT OF SUFFICIENT CONSTRUCTION TO COMPLY WITH ENERGY CODE AND ASHRAE/IESNA 90.1. 20. EXPOSED OUTDOOR SUPPLY & EXHAUST AIR DUCTS SHALL BE INSULATED WITH A MINERAL-FIBERBOARD, 3 INCHES THICK, 3-LB/CU. FT. NOMINAL DENSITY. INSTALL JACKET OVER INSULATION MATERIAL. FOR INSULATION WITH FACTORY-APPLIED JACKET, INSTALL THE FIELD-APPLIED JACKET OVER THE FACTORY-APPLIED JACKET. DUCTS AND PLENUMS, EXPOSED, UP TO 48 INCHES IN DIAMETER OR WITH FLAT SURFACES UP TO 72 INCHES: ALUMINUM, SMOOTH MINIMUM 0.020 INCHES THICK. 21. ALL SUPPLY, RETURN & OUTDOOR AIR DUCTS ROUTED IN UNCONDITIONED SPACE SHALL HAVE MINIMUM R11 INSULATION. ALL OTHER INSULATION SHALL BE PER ENERGY CODE UNLESS OTHERWISE NOTED. METAL DUCT 1. DUCT CONSTRUCTION, INCLUDING SHEET METAL THICKNESSES, SEAM AND JOINT CONSTRUCTION, REINFORCEMENTS, AND HANGERS AND SUPPORTS, SHALL COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE" AND PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA INDICATED IN "DUCT SCHEDULE" ARTICLE. 2. STRUCTURAL PERFORMANCE: DUCT HANGERS AND SUPPORTS SHALL WITHSTAND THE EFFECTS OF GRAVITY LOADS AND STRESSES WITHIN LIMITS AND UNDER CONDITIONS DESCRIBED IN SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE". 3. AIRSTREAM SURFACES: SURFACES IN CONTACT WITH THE AIRSTREAM SHALL COMPLY WITH REQUIREMENTS IN ASHRAE 62.1-2004. REFRIGERANT PIPING INSTALLATION A. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT OF PIPING SYSTEMS; INDICATED LOCATIONS AND ARRANGEMENTS WERE USED TO SIZE PIPE AND CALCULATE FRICTION LOSS, EXPANSION, PUMP SIZING, AND OTHER DESIGN CONSIDERATIONS. INSTALL PIPING AS INDICATED UNLESS DEVIATIONS TO LAYOUT ARE APPROVED ON SHOP DRAWINGS. B. INSTALL REFRIGERANT PIPING ACCORDING TO ASHRAE 15. C. INSTALL PIPING IN CONCEALED LOCATIONS UNLESS OTHERWISE INDICATED AND EXCEPT IN EQUIPMENT ROOMS AND SERVICE AREAS. D. INSTALL PIPING INDICATED TO BE EXPOSED AND PIPING IN EQUIPMENT ROOMS AND SERVICE AREAS AT RIGHT ANGLES OR PARALLEL TO BUILDING WALLS. DIAGONAL RUNS ARE PROHIBITED UNLESS SPECIFICALLY INDICATED OTHERWISE. E. INSTALL PIPING ABOVE ACCESSIBLE CEILINGS TO ALLOW SUFFICIENT SPACE FOR CEILING PANEL REMOVAL. F. INSTALL PIPING ADJACENT TO MACHINES TO ALLOW SERVICE AND MAINTENANCE. G. INSTALL PIPING FREE OF SAGS AND BENDS. H. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS. I. SELECT SYSTEM COMPONENTS WITH PRESSURE RATING EQUAL TO OR GREATER THAN SYSTEM OPERATING PRESSURE. J. INSTALL PIPING AS SHORT AND DIRECT AS POSSIBLE, WITH A MINIMUM NUMBER OF JOINTS, ELBOWS, AND FITTINGS. K. ARRANGE PIPING TO ALLOW INSPECTION AND SERVICE OF REFRIGERATION EQUIPMENT. INSTALL VALVES AND SPECIALTIES IN ACCESSIBLE LOCATIONS TO ALLOW FOR SERVICE AND INSPECTION. INSTALL ACCESS DOORS OR PANELS AS IF VALVES OR EQUIPMENT REQUIRING MAINTENANCE IS CONCEALED BEHIND FINISHED SURFACES. L. INSTALL REFRIGERANT PIPING IN PROTECTIVE CONDUIT WHERE INSTALLED BELOWGROUND. M. INSTALL REFRIGERANT PIPING IN RIGID OR FLEXIBLE CONDUIT IN LOCATIONS WHERE EXPOSED TO MECHANICAL INJURY. N. SLOPE REFRIGERANT PIPING AS FOLLOWS: 1. INSTALL HORIZONTAL HOT-GAS DISCHARGE PIPING WITH A UNIFORM SLOPE DOWNWARD AWAY FROM COMPRESSOR. 2. INSTALL HORIZONTAL SUCTION LINES WITH A UNIFORM SLOPE DOWNWARD TO COMPRESSOR. 3. INSTALL TRAPS AND DOUBLE RISERS TO ENTRAIN OIL IN VERTICAL RUNS. 4. LIQUID LINES MAY BE INSTALLED LEVEL. O. WHEN BRAZING OR SOLDERING, REMOVE SOLENOID-VALVE COILS AND SIGHT GLASSES; ALSO REMOVE VALVE STEMS, SEATS, AND PACKING, AND ACCESSIBLE INTERNAL PARTS OF REFRIGERANT SPECIALTIES. DO NOT APPLY HEAT NEAR EXPANSION-VALVE BULB. P. INSTALL PIPING WITH ADEQUATE CLEARANCE BETWEEN PIPE AND ADJACENT WALLS AND HANGERS OR BETWEEN PIPES FOR INSULATION INSTALLATION. Q. INSTALL SLEEVES FOR PIPING PENETRATIONS OF WALLS, CEILINGS, AND FLOORS. R. INSTALL SLEEVE SEALS FOR PIPING PENETRATIONS OF CONCRETE WALLS AND SLABS. S. INSTALL ESCUTCHEONS FOR PIPING PENETRATIONS OF WALLS, CEILINGS, AND FLOORS. T. PROVIDE UV PROTECTIVE COATING/COVERING ON ALL ELECTROMETRIC PIPE INSULATION WHERE EXPOSED TO THE OUTDOORS. REFRIGERANT PIPE HANGERS AND SUPPORTS PIPING HANGERS AND SUPPORTS MUST ACCOMMODATE EXPANSION AND CONTRACTION, VIBRATION, DEAD LOAD OF PIPING AND ITS CONTENTS, AND SEISMIC-BRACING REQUIREMENTS. A. HANGER, SUPPORT, AND ANCHOR PRODUCTS ARE SPECIFIED IN SECTION 230529 "HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT." B. INSTALL THE FOLLOWING PIPE ATTACHMENTS: 1. ADJUSTABLE STEEL CLEVIS HANGERS FOR INDIVIDUAL HORIZONTAL RUNS LESS THAN 20 FEET LONG. 2. ROLLER HANGERS AND SPRING HANGERS FOR INDIVIDUAL HORIZONTAL RUNS 20 FEET OR LONGER. 3. PIPE ROLLER: MSS SP-58, TYPE 44 FOR MULTIPLE HORIZONTAL PIPING 20 FEET OR LONGER, SUPPORTED ON A TRAPEZE. 4. SPRING HANGERS TO SUPPORT VERTICAL RUNS. 5. COPPER-CLAD HANGERS AND SUPPORTS FOR HANGERS AND SUPPORTS IN DIRECT CONTACT WITH COPPER PIPE. C. INSTALL HANGERS FOR COPPER TUBING WITH THE FOLLOWING MAXIMUM SPACING AND MINIMUM ROD SIZES: VERIFY ACTUAL SUPPORTED LOADS FOR HANGER SIZES AND SPACING. CONSULT STRUCTURAL ENGINEER. SPACING AND SIZES IN SUBPARAGRAPHS BELOW ARE FROM THE 2000 ASHRAE HANDBOOK - "HVAC SYSTEMS AND EQUIPMENT." 1. NPS 1/2: MAXIMUM SPAN, 60 INCHES; MINIMUM ROD SIZE, 1/4 INCH. 2. NPS 5/8: MAXIMUM SPAN, 60 INCHES; MINIMUM ROD SIZE, 1/4 INCH. 3. NPS 1: MAXIMUM SPAN, 72 INCHES; MINIMUM ROD SIZE, 1/4 INCH. 4. NPS 1-1/4: MAXIMUM SPAN, 96 INCHES; MINIMUM ROD SIZE, 3/8 INCH. 5. NPS 1-1/2: MAXIMUM SPAN, 96 INCHES; MINIMUM ROD SIZE, 3/8 INCH. 6. SUPPORT MULTIFLOOR VERTICAL RUNS AT LEAST AT EACH FLOOR. REFRIGERANT PIPE FIELD QUALITY CONTROL A. PERFORM TESTS AND INSPECTIONS AND PREPARE TEST REPORTS. B. TESTS AND INSPECTIONS: 1. COMPLY WITH ASME B31.5, CHAPTER VI. 2. TEST REFRIGERANT PIPING AND SPECIALTIES. ISOLATE COMPRESSOR, CONDENSER, EVAPORATOR, AND SAFETY DEVICES FROM TEST PRESSURE IF THEY ARE NOT RATED ABOVE THE TEST PRESSURE. 3. TEST HIGH- AND LOW-PRESSURE SIDE PIPING OF EACH SYSTEM SEPARATELY AT NOT LESS THAN THE PRESSURES INDICATED IN PART 1 "PERFORMANCE REQUIREMENTS" ARTICLE. a. FILL SYSTEM WITH NITROGEN TO THE REQUIRED TEST PRESSURE. b. SYSTEM SHALL MAINTAIN TEST PRESSURE AT THE MANIFOLD GAGE THROUGHOUT DURATION OF TEST. c. TEST JOINTS AND FITTINGS WITH ELECTRONIC LEAK DETECTOR OR BY BRUSHING A SMALL AMOUNT OF SOAP AND GLYCERIN SOLUTION OVER JOINTS. d. REMAKE LEAKING JOINTS USING NEW MATERIALS, AND RETEST UNTIL SATISFACTORY RESULTS ARE ACHIEVED. REFRIGERANT SYSTEM ADJUSTING A. ADJUST THERMOSTATIC EXPANSION VALVE TO OBTAIN PROPER EVAPORATOR SUPERHEAT. B. ADJUST HIGH- AND LOW-PRESSURE SWITCH SETTINGS TO AVOID SHORT CYCLING IN RESPONSE TO FLUCTUATING SUCTION PRESSURE. C. ADJUST SET-POINT TEMPERATURE OF AIR-CONDITIONING OR CHILLED-WATER CONTROLLERS TO THE SYSTEM DESIGN TEMPERATURE. D. PERFORM THE FOLLOWING ADJUSTMENTS BEFORE OPERATING THE REFRIGERATION SYSTEM, ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS: 1. OPEN SHUTOFF VALVES IN CONDENSER WATER CIRCUIT. 2. VERIFY THAT COMPRESSOR OIL LEVEL IS CORRECT. 3. OPEN COMPRESSOR SUCTION AND DISCHARGE VALVES. 4. OPEN REFRIGERANT VALVES EXCEPT BYPASS VALVES THAT ARE USED FOR OTHER PURPOSES. 5. CHECK OPEN COMPRESSOR-MOTOR ALIGNMENT AND VERIFY LUBRICATION FOR MOTORS AND BEARINGS. E. REPLACE CORE OF REPLACEABLE FILTER DRYER AFTER SYSTEM HAS BEEN ADJUSTED AND AFTER DESIGN FLOW RATES AND PRESSURES ARE ESTABLISHED. REFRIGERANT SYSTEM CHARGING A. CHARGE SYSTEM USING THE FOLLOWING PROCEDURES: 1. INSTALL CORE IN FILTER DRYERS AFTER LEAK TEST BUT BEFORE EVACUATION. 2. EVACUATE ENTIRE REFRIGERANT SYSTEM WITH A VACUUM PUMP TO 500 MICROMETERS. IF VACUUM HOLDS FOR 12 HOURS, SYSTEM IS READY FOR CHARGING. 3. BREAK VACUUM WITH REFRIGERANT GAS, ALLOWING PRESSURE TO BUILD UP TO 2 PSIG. 4. CHARGE SYSTEM WITH A NEW FILTER-DRYER CORE IN CHARGING LINE. REFRIGERANT PIPE JOINT CONSTRUCTION A. SOLDERED JOINTS: CONSTRUCT JOINTS ACCORDING TO ASTM B 828 OR CDA'S "COPPER TUBE HANDBOOK." B. BRAZED JOINTS: CONSTRUCT JOINTS ACCORDING TO AWS'S "BRAZING HANDBOOK," CHAPTER "PIPE AND TUBE." 1. USE TYPE BCUP, COPPER-PHOSPHORUS ALLOY FOR JOINING COPPER SOCKET FITTINGS WITH COPPER PIPE. 2. USE TYPE BAG, CADMIUM-FREE SILVER ALLOY FOR JOINING COPPER WITH BRONZE OR STEEL. COL COLUMN CONC CONCRETE CRAC COMPUTER ROOM UNIT CU CONDENSING UNIT DB DRY BULB DC DRY COOLER DDC DIRECT DIGITAL CONTROL DIA DIAMETER DP DIFFERENTIAL PRESSURE DX DIRECT EXPANSION EA EACH OR EXHAUST AIR EAT ENTERING AIR TEMPERATURE EF EXHAUST FAN EWT ENTERING WATER TEMPERATURE EXP EXPANSION F FAHRENHEIT FA FACE AREA FD FIRE DAMPER FP FAN POWERED FPM FEET PER MINUTE LF LINEAR FEET LH LATENT HEAT LVR LOUVER LWT LEAVING WATER TEMPERATURE MBU THOUSAND BTUH MFR MANUFACTURER MIN MINIMUM MOD MOTOR OPERATED DAMPER MVD MANUAL VOLUME DAMPER N/A NOT APPLICABLE NC NOISE CRITERIA NOM NOMINAL NTS NOT TO SCALE OA OUTSIDE AIR OD OUTSIDE DIAMETER P PUMP PH PHASE (ELECTRICAL) PLBG PLUMBING TOD TOP OF DUCT TYP TYPICAL U HEAT TRANSFER COEFFICIENT UCD UNDERCUT DOOR UH UNIT HEATER V VOLTS VAV VARIABLE AIR VOLUME VFD VARIABLE FREQUENCY DRIVE VOL VOLUME W WATT WB WET BULB WC WATER COLUMN WPD WATER PRESSURE DROP BDD BACK DRAFT DAMPER WITH AIR FLOW INDICATION M1.1 1ST FLOOR - MECHANICAL PLAN x 27. EACH BRANCH DUCT SERVING A DIFFUSER SHALL HAVE A MANUAL BALANCING DAMPER INSTALLED AT MAIN DUCT TAKE-OFF REGARDLESS OF DRAWING OMISSION. NEW FLEXIBLE DUCTWORK N E EXISTING DUCTWORK TO NEW DUCTWORK CONNECTION 24x12 24x12 24x12 SQUARE DUCT TAKE OFF, TOP SQUARE DUCT TAKE OFF, BOTTOM SQUARE DUCT TAKE OFF, TOP SQUARE DUCT TAKE OFF, BOTTOM RND ELBOW 45°, RADIUS 24" SQ ELBOW 45°, RADIUS 24x24 SQ ELBOW 45°, MITERED 24x24 SQ TO RND CONCENTRIC TRANSITION IN DROP SQ TO RND CONCENTRIC TRANSITION IN RISE SQ TO SQ ECCENTRIC TRANSITION SQ TO SQ CONCENTRIC TRANSITION SQ TO RND ECCENTRIC TRANSITION SQ TO RND CONCENTRIC TRANSITION 24x12 24x12 24x12 24" 24" RND ELBOW 45°, RADIUS 24" RND ELBOW 90°, MITERED RND ELBOW 90°, RADIUS SQUARE ELBOW, NO TURNING VANES RND DUCT ELEVATION CHANGE, UP RND DUCT ELEVATION CHANGE, DOWN NEW DUCTWORK WITH LINER ROUND DUCT TAKE OFF 24" DUCTWORK DIMENSION LABEL (24" DIAMETER) 24x12 DUCTWORK DIMENSION LABEL (24" WIDTH x 12" HEIGHT) SQUARE DUCT TAKE OFF, SIDE SQ DUCT ELEVATION CHANGE, 90° UP SQ DUCT ELEVATION CHANGE, 90° DOWN NEW RIGID DUCTWORK EXISTING DUCTWORK TO BE DEMOLISHED EXISTING DUCTWORK TO REMAIN SQUARE ELBOW WITH DOUBLE THICKNESS TURNING VANES Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø M1.3 x M1.4 x M1.5 ROOF - MECHANICAL PLAN M2.1 MECHANICAL SCHEDULES 1 OF 2 M2.2 MECHANICAL SCHEDULES 2 OF 2 2ND FLOOR - MECHANICAL PLAN 3RD FLOOR - MECHANICAL PLAN 4TH FLOOR - MECHANICAL PLAN x x x M3.1 MECHANICAL DETAILS 1 OF 2 x x M3.2 MECHANICAL DETAILS 2 OF 2 Ø M1.5 MECHANICAL ENLARGEMENT PLANS x

Transcript of 100% CDS - F.T. James

AEED,Advanced Energy Engineering & Design, Inc

CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369

P.O. BOX 4934408 McCALLIE AVE

inc.

AEED JOB NO. 029-15

COPYRIGHT NOTICE

THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.

714

cher

ry s

treet

, cha

ttano

oga,

tenn

esse

e 37

402

p.42

3 63

4 08

06 f

.423

752

849

9 w

ww

.rive

r-st

-arc

hite

ctur

e.co

m

Release Date:Project No.:

3/31

/201

5 10

:17:

24 A

M

1205

5 G

ATE

WA

Y W

ES

T B

LVD

, EL

PA

SO

, TX

CO

UR

TY

AR

D B

Y M

AR

RIO

TT

ZAR

AG

OZA

HO

TEL

PA

RTN

ER

S, L

LC

MECHANICAL

M0.1

COVER SHEET

S

R

M0.1 MECHANICAL COVER SHEET

M1.2

6/25

/201

610

0% C

DS

x

x

MECHANICAL SHEET INDEX ISSUE LOG

TITLE#

DAT

E

HVAC GENERAL NOTES

1. THESE GENERAL NOTES APPLY TO ALL MECHANICAL DRAWINGS. IN THE EVENT THAT ANYGENERAL NOTE CONFLICTS WITH THE WRITTEN CONSTRUCTION SPECIFICATIONS, THE

2. CONTRACTOR SHALL PROVIDE ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO INSTALL ACOMPLETE AND OPERABLE MECHANICAL SYSTEM AS INDICATED ON THE DRAWINGS,SPECIFICATIONS AND IN ACCORDANCE WITH APPLICABLE CODES.

3. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'SWRITTEN INSTRUCTIONS. THE CONTRACTOR SHALL PROVIDE ALL HANGERS AND SUPPORTS (INCOMPLIANCE WITH SEISMIC CATEGORY “C”) REQUIRED FOR A COMPLETE INSTALLATION.

4. THE MECHANICAL DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE ANDGENERAL ARRANGEMENT ONLY. DO NOTE SCALE DRAWINGS.

5. COORDINATE ALL MECHANICAL WORK WITH OTHER TRADES TO INSURE PROPER CLEARANCE ANDSPATIAL RELATIONSHIPS TO OTHER EQUIPMENT AND STRUCTURAL COMPONENTS.

6. COORDINATE ALL EQUIPMENT CONNECTIONS WITH MANUFACTURER'S CERTIFIED DRAWINGS.COORDINATE AND PROVIDE ALL DUCT AND PIPE TRANSITIONS REQUIRED FOR FINALCONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY ALL DUCT AND PIPE DIMENSIONSPRIOR TO FABRICATION.

8. PROVIDE FLEXIBLE DUCT AND PIPE CONNECTIONS TO ALL MECHANICAL EQUIPMENT.

9. ALL CONTROL WIRING AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE. ALLCONTROL WIRING IN RETURN PLENUMS SHALL BE PLENUM RATED. CONTROL WIRING LOCATEDIN MECHANICAL ROOMS SHALL BE ROUTED IN RIGID CONDUIT.

10. CONTRACTOR IS RESPONSIBLE FOR THE RESTART OF ANY SYSTEMS DE-ENERGIZED TOACCOMMODATE THIS WORK.

12. PROVIDE AND INSTALL ACCESS PANELS/DOORS IN WALLS, CEILINGS AND DUCTWORK ASREQUIRED TO ACCESS/SERVICE VALVES, DUCT DETECTORS, CONTROL COMPONENTS, FIREDAMPERS AND OTHER CONCEALED MECHANICAL DEVISES.

13. ALL DUCT DIMENSIONS ARE INSIDE CLEAR UNLESS OTHERWISE NOTED. ALL DUCT DIMENSIONSSHALL BE MODIFIED AS REQUIRED TO ACCOUNT FOR DUCT INSULATION.

14. LOCATE ALL MECHANICAL EQUIPMENT TO FACILITATE UNOBSTRUCTED AIR/WATER FLOW ANDACCESS TO UNIT SERVICE PANELS, CONTROLS AND VALVES AS REQUIRED BY THEMANUFACTURER AND APPLICABLE CODES.

15. ALL AIR/HYDRONIC LEAK TESTING AND INSPECTIONS SHALL BE COMPLETED PRIOR TO THEAPPLICATION OF INSULATING MATERIALS. FAILURE TO COMPLY WITH THIS REQUIREMENT MAYRESULT IN THE REMOVAL AND REAPPLICATION OF THE INSULATION AT THE CONTRACTORS

EXPENSE.

16. LOCATE ALL TEMPERATURE, PRESSURE, FLOW MEASURING DEVICES AND COMPONENTS INACCESSIBLE LOCATIONS WITH STRAIGHT SECTIONS OF PIPE/DUCTWORK UP AND DOWN STREAMOF DEVICE AS OUTLINED BY THE EQUIPMENT MANUFACTURER.

17. TESTING, ADJUSTING AND BALANCING CONTRACTOR SHALL BE A CURRENT AND RECOGNIZEDMEMBER OF THE AABC OR NEBB AS OUTLINED IN THE CONSTRUCTION SPECIFICATIONS.

18. ALL DUCTWORK, PIPING OR EQUIPMENT SUPPORTED FROM THE STRUCTURE SHALL BECOORDINATED WITH THE GENERAL CONTRACTOR. CONTRACTOR RESPONSIBLE FOR THEREPAIR/REPLACEMENT OF ANY FIREPROOFING REMOVED TO ACCOMMODATE HANGERATTACHMENT.

19. ALL NEW/MODIFIED SUPPLY DUCTWORK SHALL BE EXTERNAL INSULATED IN ACCORDANCE WITHTHE CONSTRUCTION SPECIFICATIONS.

20. CONFIRM LOCATIONS OF FIRE RATED CEILINGS, WALLS AND FLOORS. FIRE SEAL ALLPENETRATIONS WITH FIRE STOP SEALANT. DUCTWORK THAT PENETRATES FIRE PARTITIONSSHALL BE EQUIPPED WITH FIRE DAMPERS.

21. OFFSET DUCTWORK AS REQUIRED TO ACCOMMODATE THE ARCHITECTURAL REFLECTIVE CEILING PLAN.

22. NO SUPPLY DIFFUSER SHALL BE LOCATED WITHIN 36” OF ANY SMOKE DETECTOR OR AUTOMATICSPRINKLER HEAD/DEVICE.

23. ALL 45 DEGREE OR GREATER ELBOWS (INCLUDING THOSE AT DIFFUSER CONNECTIONS) SHALL BE CONSTRUCTED OF RIGID DUCTWORK.

24. ALL WORK SHALL BE PREFORMED IN ACCORDANCE WITH SITE CONSTRUCTION AND SAFETYREQUIREMENTS. NO WORK SHALL BE PERFORMED WITHOUT A VALID JOB SCHEDULE AND FIREALARM PERMITS (WHERE REQUIRED). ALL WORKERS MUST REGISTER WITH THE LOCALMAINTENANCE CONTRACTOR PRIOR TO PERFORMING ANY WORK.

25. ALL WASTE OR DISCARDED MATERIALS SHALL BE RECYCLED IN ACCORDANCE WITH SITECONSTRUCTION POLICIES. REPORT ALL RECYCLED MATERIAL QUANTITIES TO PROJECTENGINEER. WRITTEN REPORT SHALL INCLUDE MATERIAL TYPE, QUANTITIES, AND DISPOSITIONOF THE MATERIALS.

26. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE SET OF AS-BUILTDRAWINGS DETAILING ALL FIELD MODIFICATIONS TO THE DESIGN DRAWINGS. DRAWINGSSHALL INCLUDE LOCATION AND ELEVATION REFERENCED FROM FINISHED FLOOR.

MOST STRINGENT OF THE TWO SHALL RULE.

11. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLINGOVER 2000 CFM, MOUNTED IN SA DUCT (NFPA 90A, 4-4.2), AND IN RA DUCT PRIOR TOEXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNITSERVING BUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S)TO STOP UNIT FAN IF SMOKE IS DETECTED. INTERLOCK WITH FIRE ALARM SYSTEM IF APPLICABLE.

DIFFUSER TYPEDESIGNATION

AIR QUANTITY

NOTE:RUNOUT SIZE TO

DIFFUSER IS THESAME SIZE AS THE

ROUND NECK

NOTED OTHERWISE.DIFFUSER NECK UNLESS

2410

360 CFM

B

FIRE DAMPERFD

DUCTWORKDUCTWORK - AIR TERMINALS

DUCTWORK - EQUIPMENT

SMOKE DAMPERSD

COMBINATION FIRE & SMOKE DAMPERFSD

M

SMOKE DETECTORSDT

EQUIPMENT - HVAC

EDH-xELECTRIC DUCT HEATER, WITH TAG

HVAC- AIR DISTRIBUTION TAG

AC AIR CONDITIONING UNITAD ACCESS DOORAFF ABOVE FINISHED FLOORAHU AIR HANDLING UNITAMB AMBIENTAP ACCESS PANELAS AIR STREAMATM ATMOSPHEREBD BALANCING DAMPERBDD BACK DRAFT DAMPERBHP BRAKE HORSEPOWERBLDG BUILDINGBOD BOTTOM OF DUCTBTU BRITISH THERMAL UNITBTUH BTU PER HOURCC COOLING COILCF CUBIC FEETCFM CUBIC FEET PER MINUTECLG CEILING

ABBREVIATIONS

CU,HP-x

CU,HP-x

DIFFUSER SIZE EXAMPLE:24x24 DIFFUSER WITH A

10"� NECK.

VARIABLE AIR VOLUME BOX WITH TAG,DUCT SHOWN

ROOF/CURB MOUNTED AIR HANDLINGUNIT, DUCT NOT SHOWN

INDOOR HORIZONTAL AIR HANDLINGEQUIP, DUCT SHOWN

INDOOR VERTICAL AIR HANDLINGEQUIP, DUCT NOT SHOWN

ROOF/CURB MOUNTED EXHAUST FANWITH TAG, DUCT SHOWN

INLINE SUSPENDED MOUNT EXHAUSTFAN WITH TAG, DUCT SHOWN

EF-x CEILING MOUNTED EXHAUST FANWITH TAG, DUCT SHOWN

CONDENSING UNIT ONEQUIPMENT RAILS WITH TAG

CONDENSING UNIT ON CONCRETEHOUSE KEEPING PAD WITH TAG

SIDEWALL GRILLE TAP WITHMANUAL VOLUME DAMPER, SQ

24x24

24" SIDEWALL GRILLE TAP WITHMANUAL VOLUME DAMPER, RND

MOTORIZED DAMPER

EXHAUST AIR GRILLE; EXHAUSTDUCT AND MVD IN SECTION

RETURN AIR GRILLE; RETURNDUCT AND MVD IN SECTION

SUPPLY AIR DIFFUSER; SUPPLYDUCT AND MVD IN SECTION

MVD; MANUALBALANCING/VOLUME DAMPER

HVAC LEGEND

FPS FEET PER SECONDFS FLOW SWITCHFSD COMB SMOKE FIRE DAMPERFT FOOT OR FEETG GASGAL GALLONSGALV GALVANIZEDGPM GALLONS PER MINUTEHP HORSEPOWERHR HOURHT HEIGHTHX HEAT EXCHANGERHz FREQUENCYID INSIDE DIAMETERIN INCHkW KILOWATTkWh KILOWATT HOURL LENGTHLAT LEAVING AIR TEMPERATURE

PSFG POUNDS PER SQUARE FOOTPSIG POUNDS PER SQUARE INCHQTY QUANTITYR RADIUSRA RETURN AIRREQ'D REQUIREDRF RETURN FANRH HUMIDITY, RELATIVERLA RUNNING LOAD AMPSRM ROOMSA SUPPLY AIRSD SMOKE DAMPERSF SUPPLY FANSG SPECIFIC GRAVITYSH SENSIBLE HEATSHR SENSIBLE HEAT RATIOSP STATIC PRESSURESPEC SPECIFICATIONSSQ SQUARE

MECHANICAL SPECIFICATIONS

EQUIPMENT INSTALLATION - COMMON REQUIREMENTS1. INSTALL EQUIPMENT LEVEL AND PLUMB, PARALLEL AND PERPENDICULAR TO OTHER

BUILDING SYSTEMS AND COMPONENTS IN EXPOSED INTERIOR SPACES, UNLESSOTHERWISE INDICATED.

2. INSTALL HVAC EQUIPMENT TO FACILITATE SERVICE, MAINTENANCE, AND REPAIR ORREPLACEMENT OF COMPONENTS. CONNECT EQUIPMENT FOR EASE OFDISCONNECTING, WITH MINIMUM INTERFERENCE TO OTHER INSTALLATIONS.EXTEND GREASE FITTINGS TO ACCESSIBLE LOCATIONS.

3. INSTALL EQUIPMENT TO ALLOW RIGHT OF WAY FOR PIPING INSTALLED ATREQUIRED SLOPE.

4. DAMAGE AND TOUCHUP: REPAIR MARRED AND DAMAGED FACTORY-PAINTEDFINISHES WITH MATERIALS AND PROCEDURES TO MATCH ORIGINAL FACTORYFINISH.

DUCT HANGER AND SUPPORT INSTALLATION1. COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND

FLEXIBLE," CHAPTER 4, "HANGERS AND SUPPORTS."

2. HANGER SPACING: COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTIONSTANDARDS - METAL AND FLEXIBLE," TABLE 4-1, "RECTANGULAR DUCT HANGERSMINIMUM SIZE," AND TABLE 4-2, "MINIMUM HANGER SIZES FOR ROUND DUCT," FORMAXIMUM HANGER SPACING; INSTALL HANGERS AND SUPPORTS WITHIN 24 INCHESOF EACH ELBOW AND WITHIN 48 INCHES OF EACH BRANCH INTERSECTION.

3. HANGERS EXPOSED TO VIEW: THREADED ROD AND ANGLE OR CHANNEL SUPPORTS.

4. SUPPORT VERTICAL DUCTS WITH STEEL ANGLES OR CHANNEL SECURED TO THESIDES OF THE DUCT WITH WELDS, BOLTS, SHEET METAL SCREWS, OR BLINDRIVETS; SUPPORT AT EACH FLOOR AND AT A MAXIMUM INTERVALS OF 16 FEET.

5. INSTALL UPPER ATTACHMENTS TO STRUCTURES. SELECT AND SIZE UPPERATTACHMENTS WITH PULL-OUT, TENSION, AND SHEAR CAPACITIES APPROPRIATEFOR SUPPORTED LOADS AND BUILDING MATERIALS WHERE USED.

DUCT INSTALLATION

1. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION ANDARRANGEMENT OF DUCT SYSTEM. INDICATED DUCT LOCATIONS, CONFIGURATIONS,AND ARRANGEMENTS WERE USED TO SIZE DUCTS AND CALCULATE FRICTION LOSSFOR AIR-HANDLING EQUIPMENT SIZING AND FOR OTHER DESIGN CONSIDERATIONS.INSTALL DUCT SYSTEMS AS INDICATED UNLESS DEVIATIONS TO LAYOUT AREAPPROVED ON SHOP DRAWINGS AND COORDINATION DRAWINGS.

2. INSTALL DUCTS ACCORDING TO SMACNA'S "HVAC DUCT CONSTRUCTIONSTANDARDS - METAL AND FLEXIBLE" UNLESS OTHERWISE INDICATED.

3. INSTALL DUCTS WITH FEWEST POSSIBLE JOINTS.

4. INSTALL FACTORY- OR SHOP-FABRICATED FITTINGS FOR CHANGES IN DIRECTION,SIZE, AND SHAPE AND FOR BRANCH CONNECTIONS.

5. UNLESS OTHERWISE INDICATED, INSTALL DUCTS VERTICALLY AND HORIZONTALLY,AND PARALLEL AND PERPENDICULAR TO BUILDING LINES.

6. INSTALL DUCTS CLOSE TO WALLS, OVERHEAD CONSTRUCTION, COLUMNS, ANDOTHER STRUCTURAL AND PERMANENT ENCLOSURE ELEMENTS OF BUILDING.

7. INSTALL DUCTS WITH A CLEARANCE OF 1 INCH, PLUS ALLOWANCE FOR INSULATIONTHICKNESS.

8. ROUTE DUCTS TO AVOID PASSING THROUGH TRANSFORMER VAULTS ANDELECTRICAL EQUIPMENT ROOMS AND ENCLOSURES.

9. WHERE DUCTS PASS THROUGH FIRE-RATED INTERIOR PARTITIONS AND EXTERIORWALLS, INSTALL FIRE DAMPERS.

10. PROTECT DUCT INTERIORS FROM MOISTURE, CONSTRUCTION DEBRIS AND DUST,AND OTHER FOREIGN MATERIALS

11. PROTECT EXPOSED DUCTS FROM BEING DENTED, SCRATCHED, OR DAMAGED.

12. TRIM DUCT SEALANTS FLUSH WITH METAL. CREATE A SMOOTH AND UNIFORMEXPOSED BEAD. DO NOT USE TWO-PART TAPE SEALING SYSTEM.

13. GRIND WELDS TO PROVIDE SMOOTH SURFACE FREE OF BURRS, SHARP EDGES, ANDWELD SPLATTER. WHEN WELDING STAINLESS STEEL WITH A NO. 3 OR 4 FINISH,GRIND THE WELDS FLUSH, POLISH THE EXPOSED WELDS, AND TREAT THE WELDSTO REMOVE DISCOLORATION CAUSED BY WELDING.

14. MAINTAIN CONSISTENCY, SYMMETRY, AND UNIFORMITY IN THE ARRANGEMENT ANDFABRICATION OF FITTINGS, HANGERS AND SUPPORTS, DUCT ACCESSORIES, ANDAIR OUTLETS.

15. REPAIR OR REPLACE DAMAGED SECTIONS AND FINISHED WORK THAT DOES NOTCOMPLY WITH THESE REQUIREMENTS.

16. SEAL DUCTS TO THE FOLLOWING SEAL CLASSES ACCORDING TO SMACNA'S "HVACDUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE":

• COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METALAND FLEXIBLE."

• OUTDOOR, SUPPLY-AIR DUCTS: SEAL CLASS A.• OUTDOOR, EXHAUST DUCTS: SEAL CLASS C.• OUTDOOR, RETURN-AIR DUCTS: SEAL CLASS C.• UNCONDITIONED SPACE, SUPPLY-AIR DUCTS IN PRESSURE CLASSES 2-INCH

WG AND LOWER: SEAL CLASS B.• UNCONDITIONED SPACE, SUPPLY-AIR DUCTS IN PRESSURE CLASSES HIGHER

THAN 2-INCH WG: SEAL CLASS A.• UNCONDITIONED SPACE, EXHAUST DUCTS: SEAL CLASS C.• UNCONDITIONED SPACE, RETURN-AIR DUCTS: SEAL CLASS B.• CONDITIONED SPACE, SUPPLY-AIR DUCTS IN PRESSURE CLASSES 2-INCH WG

AND LOWER: SEAL CLASS C.• CONDITIONED SPACE, SUPPLY-AIR DUCTS IN PRESSURE CLASSES HIGHER

THAN 2-INCH WG: SEAL CLASS B.• CONDITIONED SPACE, EXHAUST DUCTS: SEAL CLASS B.• CONDITIONED SPACE, RETURN-AIR DUCTS: SEAL CLASS C.

17. THE INSTALLATION OF ALL INSULATION SHALL BE PERFORMED BY AN EXPERIENCEDCRAFTSMAN IN A NEAT WORKMANSHIP-LIKE MANNER AND SHALL BE INACCORDANCE WITH THE MANUFACTURER'S WRITTEN PUBLISHEDRECOMMENDATIONS FOR SERVICE INTENDED.

18. CONCEALED INDOOR SUPPLY, RETURN & OUTDOOR AIR DUCTS SHALL BE INSULATEDWITH A MINERAL-FIBER BLANKET, 2 INCHES THICK, 1.5-LB/CU. FT. NOMINALDENSITY.

19. EXPOSED INDOOR SUPPLY & RETURN DUCTS SHALL BE DOUBLE WALL DUCT OFSUFFICIENT CONSTRUCTION TO COMPLY WITH ENERGY CODE ANDASHRAE/IESNA 90.1.

20. EXPOSED OUTDOOR SUPPLY & EXHAUST AIR DUCTS SHALL BE INSULATED WITH AMINERAL-FIBERBOARD, 3 INCHES THICK, 3-LB/CU. FT. NOMINAL DENSITY. INSTALLJACKET OVER INSULATION MATERIAL. FOR INSULATION WITH FACTORY-APPLIEDJACKET, INSTALL THE FIELD-APPLIED JACKET OVER THE FACTORY-APPLIED JACKET.DUCTS AND PLENUMS, EXPOSED, UP TO 48 INCHES IN DIAMETER OR WITH FLATSURFACES UP TO 72 INCHES: ALUMINUM, SMOOTH MINIMUM 0.020 INCHES THICK.

21. ALL SUPPLY, RETURN & OUTDOOR AIR DUCTS ROUTED IN UNCONDITIONED SPACESHALL HAVE MINIMUM R11 INSULATION. ALL OTHER INSULATION SHALL BE PERENERGY CODE UNLESS OTHERWISE NOTED.

METAL DUCT1. DUCT CONSTRUCTION, INCLUDING SHEET METAL THICKNESSES, SEAM AND JOINT

CONSTRUCTION, REINFORCEMENTS, AND HANGERS AND SUPPORTS, SHALL COMPLYWITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE"AND PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA INDICATED IN "DUCTSCHEDULE" ARTICLE.

2. STRUCTURAL PERFORMANCE: DUCT HANGERS AND SUPPORTS SHALL WITHSTANDTHE EFFECTS OF GRAVITY LOADS AND STRESSES WITHIN LIMITS AND UNDERCONDITIONS DESCRIBED IN SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE".

3. AIRSTREAM SURFACES: SURFACES IN CONTACT WITH THE AIRSTREAM SHALLCOMPLY WITH REQUIREMENTS IN ASHRAE 62.1-2004.

REFRIGERANT PIPING INSTALLATIONA. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND

ARRANGEMENT OF PIPING SYSTEMS; INDICATED LOCATIONS AND ARRANGEMENTSWERE USED TO SIZE PIPE AND CALCULATE FRICTION LOSS, EXPANSION, PUMPSIZING, AND OTHER DESIGN CONSIDERATIONS. INSTALL PIPING AS INDICATEDUNLESS DEVIATIONS TO LAYOUT ARE APPROVED ON SHOP DRAWINGS.

B. INSTALL REFRIGERANT PIPING ACCORDING TO ASHRAE 15.

C. INSTALL PIPING IN CONCEALED LOCATIONS UNLESS OTHERWISE INDICATED ANDEXCEPT IN EQUIPMENT ROOMS AND SERVICE AREAS.

D. INSTALL PIPING INDICATED TO BE EXPOSED AND PIPING IN EQUIPMENT ROOMS ANDSERVICE AREAS AT RIGHT ANGLES OR PARALLEL TO BUILDING WALLS. DIAGONALRUNS ARE PROHIBITED UNLESS SPECIFICALLY INDICATED OTHERWISE.

E. INSTALL PIPING ABOVE ACCESSIBLE CEILINGS TO ALLOW SUFFICIENT SPACE FORCEILING PANEL REMOVAL.

F. INSTALL PIPING ADJACENT TO MACHINES TO ALLOW SERVICE AND MAINTENANCE.

G. INSTALL PIPING FREE OF SAGS AND BENDS.

H. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS.

I. SELECT SYSTEM COMPONENTS WITH PRESSURE RATING EQUAL TO OR GREATERTHAN SYSTEM OPERATING PRESSURE.

J. INSTALL PIPING AS SHORT AND DIRECT AS POSSIBLE, WITH A MINIMUM NUMBER OFJOINTS, ELBOWS, AND FITTINGS.

K. ARRANGE PIPING TO ALLOW INSPECTION AND SERVICE OF REFRIGERATIONEQUIPMENT. INSTALL VALVES AND SPECIALTIES IN ACCESSIBLE LOCATIONS TOALLOW FOR SERVICE AND INSPECTION. INSTALL ACCESS DOORS OR PANELS AS IFVALVES OR EQUIPMENT REQUIRING MAINTENANCE IS CONCEALED BEHIND FINISHEDSURFACES.

L. INSTALL REFRIGERANT PIPING IN PROTECTIVE CONDUIT WHERE INSTALLEDBELOWGROUND.

M. INSTALL REFRIGERANT PIPING IN RIGID OR FLEXIBLE CONDUIT IN LOCATIONSWHERE EXPOSED TO MECHANICAL INJURY.

N. SLOPE REFRIGERANT PIPING AS FOLLOWS:

1. INSTALL HORIZONTAL HOT-GAS DISCHARGE PIPING WITH A UNIFORM SLOPEDOWNWARD AWAY FROM COMPRESSOR.

2. INSTALL HORIZONTAL SUCTION LINES WITH A UNIFORM SLOPE DOWNWARD TOCOMPRESSOR.

3. INSTALL TRAPS AND DOUBLE RISERS TO ENTRAIN OIL IN VERTICAL RUNS.

4. LIQUID LINES MAY BE INSTALLED LEVEL.

O. WHEN BRAZING OR SOLDERING, REMOVE SOLENOID-VALVE COILS AND SIGHTGLASSES; ALSO REMOVE VALVE STEMS, SEATS, AND PACKING, AND ACCESSIBLEINTERNAL PARTS OF REFRIGERANT SPECIALTIES. DO NOT APPLY HEAT NEAREXPANSION-VALVE BULB.

P. INSTALL PIPING WITH ADEQUATE CLEARANCE BETWEEN PIPE AND ADJACENT WALLSAND HANGERS OR BETWEEN PIPES FOR INSULATION INSTALLATION.

Q. INSTALL SLEEVES FOR PIPING PENETRATIONS OF WALLS, CEILINGS, AND FLOORS.

R. INSTALL SLEEVE SEALS FOR PIPING PENETRATIONS OF CONCRETE WALLS ANDSLABS.

S. INSTALL ESCUTCHEONS FOR PIPING PENETRATIONS OF WALLS, CEILINGS, ANDFLOORS.

T. PROVIDE UV PROTECTIVE COATING/COVERING ON ALL ELECTROMETRIC PIPEINSULATION WHERE EXPOSED TO THE OUTDOORS.

REFRIGERANT PIPE HANGERS AND SUPPORTSPIPING HANGERS AND SUPPORTS MUST ACCOMMODATE EXPANSION AND CONTRACTION,VIBRATION, DEAD LOAD OF PIPING AND ITS CONTENTS, AND SEISMIC-BRACINGREQUIREMENTS.

A. HANGER, SUPPORT, AND ANCHOR PRODUCTS ARE SPECIFIED IN SECTION 230529"HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT."

B. INSTALL THE FOLLOWING PIPE ATTACHMENTS:

1. ADJUSTABLE STEEL CLEVIS HANGERS FOR INDIVIDUAL HORIZONTAL RUNS LESSTHAN 20 FEET LONG.

2. ROLLER HANGERS AND SPRING HANGERS FOR INDIVIDUAL HORIZONTAL RUNS 20FEET OR LONGER.

3. PIPE ROLLER: MSS SP-58, TYPE 44 FOR MULTIPLE HORIZONTAL PIPING 20 FEETOR LONGER, SUPPORTED ON A TRAPEZE.

4. SPRING HANGERS TO SUPPORT VERTICAL RUNS.

5. COPPER-CLAD HANGERS AND SUPPORTS FOR HANGERS AND SUPPORTS INDIRECT CONTACT WITH COPPER PIPE.

C. INSTALL HANGERS FOR COPPER TUBING WITH THE FOLLOWING MAXIMUM SPACINGAND MINIMUM ROD SIZES:

VERIFY ACTUAL SUPPORTED LOADS FOR HANGER SIZES AND SPACING. CONSULTSTRUCTURAL ENGINEER. SPACING AND SIZES IN SUBPARAGRAPHS BELOW ARE FROM THE2000 ASHRAE HANDBOOK - "HVAC SYSTEMS AND EQUIPMENT."

1. NPS 1/2: MAXIMUM SPAN, 60 INCHES; MINIMUM ROD SIZE, 1/4 INCH.

2. NPS 5/8: MAXIMUM SPAN, 60 INCHES; MINIMUM ROD SIZE, 1/4 INCH.

3. NPS 1: MAXIMUM SPAN, 72 INCHES; MINIMUM ROD SIZE, 1/4 INCH.

4. NPS 1-1/4: MAXIMUM SPAN, 96 INCHES; MINIMUM ROD SIZE, 3/8 INCH.

5. NPS 1-1/2: MAXIMUM SPAN, 96 INCHES; MINIMUM ROD SIZE, 3/8 INCH.

6. SUPPORT MULTIFLOOR VERTICAL RUNS AT LEAST AT EACH FLOOR.

REFRIGERANT PIPE FIELD QUALITY CONTROLA. PERFORM TESTS AND INSPECTIONS AND PREPARE TEST REPORTS.

B. TESTS AND INSPECTIONS:

1. COMPLY WITH ASME B31.5, CHAPTER VI.

2. TEST REFRIGERANT PIPING AND SPECIALTIES. ISOLATE COMPRESSOR,CONDENSER, EVAPORATOR, AND SAFETY DEVICES FROM TEST PRESSURE IF THEYARE NOT RATED ABOVE THE TEST PRESSURE.

3. TEST HIGH- AND LOW-PRESSURE SIDE PIPING OF EACH SYSTEM SEPARATELY ATNOT LESS THAN THE PRESSURES INDICATED IN PART 1 "PERFORMANCEREQUIREMENTS" ARTICLE.

a. FILL SYSTEM WITH NITROGEN TO THE REQUIRED TEST PRESSURE.

b. SYSTEM SHALL MAINTAIN TEST PRESSURE AT THE MANIFOLD GAGETHROUGHOUT DURATION OF TEST.

c. TEST JOINTS AND FITTINGS WITH ELECTRONIC LEAK DETECTOR OR BYBRUSHING A SMALL AMOUNT OF SOAP AND GLYCERIN SOLUTION OVERJOINTS.

d. REMAKE LEAKING JOINTS USING NEW MATERIALS, AND RETEST UNTILSATISFACTORY RESULTS ARE ACHIEVED.

REFRIGERANT SYSTEM ADJUSTINGA. ADJUST THERMOSTATIC EXPANSION VALVE TO OBTAIN PROPER EVAPORATOR

SUPERHEAT.

B. ADJUST HIGH- AND LOW-PRESSURE SWITCH SETTINGS TO AVOID SHORT CYCLING INRESPONSE TO FLUCTUATING SUCTION PRESSURE.

C. ADJUST SET-POINT TEMPERATURE OF AIR-CONDITIONING OR CHILLED-WATERCONTROLLERS TO THE SYSTEM DESIGN TEMPERATURE.

D. PERFORM THE FOLLOWING ADJUSTMENTS BEFORE OPERATING THE REFRIGERATIONSYSTEM, ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS:

1. OPEN SHUTOFF VALVES IN CONDENSER WATER CIRCUIT.

2. VERIFY THAT COMPRESSOR OIL LEVEL IS CORRECT.

3. OPEN COMPRESSOR SUCTION AND DISCHARGE VALVES.

4. OPEN REFRIGERANT VALVES EXCEPT BYPASS VALVES THAT ARE USED FOR OTHERPURPOSES.

5. CHECK OPEN COMPRESSOR-MOTOR ALIGNMENT AND VERIFY LUBRICATION FORMOTORS AND BEARINGS.

E. REPLACE CORE OF REPLACEABLE FILTER DRYER AFTER SYSTEM HAS BEEN ADJUSTEDAND AFTER DESIGN FLOW RATES AND PRESSURES ARE ESTABLISHED.

REFRIGERANT SYSTEM CHARGINGA. CHARGE SYSTEM USING THE FOLLOWING PROCEDURES:

1. INSTALL CORE IN FILTER DRYERS AFTER LEAK TEST BUT BEFORE EVACUATION.

2. EVACUATE ENTIRE REFRIGERANT SYSTEM WITH A VACUUM PUMP TO 500MICROMETERS. IF VACUUM HOLDS FOR 12 HOURS, SYSTEM IS READY FORCHARGING.

3. BREAK VACUUM WITH REFRIGERANT GAS, ALLOWING PRESSURE TO BUILD UP TO2 PSIG.

4. CHARGE SYSTEM WITH A NEW FILTER-DRYER CORE IN CHARGING LINE.

REFRIGERANT PIPE JOINT CONSTRUCTIONA. SOLDERED JOINTS: CONSTRUCT JOINTS ACCORDING TO ASTM B 828 OR CDA'S

"COPPER TUBE HANDBOOK."

B. BRAZED JOINTS: CONSTRUCT JOINTS ACCORDING TO AWS'S "BRAZING HANDBOOK,"CHAPTER "PIPE AND TUBE."

1. USE TYPE BCUP, COPPER-PHOSPHORUS ALLOY FOR JOINING COPPER SOCKETFITTINGS WITH COPPER PIPE.

2. USE TYPE BAG, CADMIUM-FREE SILVER ALLOY FOR JOINING COPPER WITHBRONZE OR STEEL.

COL COLUMN CONC CONCRETECRAC COMPUTER ROOM UNITCU CONDENSING UNITDB DRY BULBDC DRY COOLERDDC DIRECT DIGITAL CONTROLDIA DIAMETERDP DIFFERENTIAL PRESSUREDX DIRECT EXPANSIONEA EACH OR EXHAUST AIREAT ENTERING AIR TEMPERATUREEF EXHAUST FANEWT ENTERING WATER TEMPERATUREEXP EXPANSIONF FAHRENHEITFA FACE AREAFD FIRE DAMPERFP FAN POWEREDFPM FEET PER MINUTE

LF LINEAR FEETLH LATENT HEATLVR LOUVERLWT LEAVING WATER TEMPERATUREMBU THOUSAND BTUHMFR MANUFACTURERMIN MINIMUMMOD MOTOR OPERATED DAMPERMVD MANUAL VOLUME DAMPERN/A NOT APPLICABLENC NOISE CRITERIANOM NOMINALNTS NOT TO SCALEOA OUTSIDE AIROD OUTSIDE DIAMETERP PUMPPH PHASE (ELECTRICAL)PLBG PLUMBING

TOD TOP OF DUCTTYP TYPICALU HEAT TRANSFER COEFFICIENTUCD UNDERCUT DOORUH UNIT HEATERV VOLTSVAV VARIABLE AIR VOLUMEVFD VARIABLE FREQUENCY DRIVEVOL VOLUMEW WATTWB WET BULBWC WATER COLUMNWPD WATER PRESSURE DROP

BDD BACK DRAFT DAMPER WITHAIR FLOW INDICATION

M1.1 1ST FLOOR - MECHANICAL PLAN x

27. EACH BRANCH DUCT SERVING A DIFFUSER SHALL HAVE A MANUAL BALANCING DAMPER INSTALLEDAT MAIN DUCT TAKE-OFF REGARDLESS OF DRAWING OMISSION.

NEW FLEXIBLE DUCTWORK

N E

EXISTING DUCTWORK TO NEWDUCTWORK CONNECTION

24x12

24x12

24x12

SQUARE DUCT TAKE OFF, TOP

SQUARE DUCT TAKE OFF, BOTTOM

SQUARE DUCT TAKE OFF, TOP

SQUARE DUCT TAKE OFF, BOTTOM

RND ELBOW 45°, RADIUS24"

SQ ELBOW 45°, RADIUS24x24

SQ ELBOW 45°, MITERED24x24

SQ TO RND CONCENTRICTRANSITION IN DROP

SQ TO RND CONCENTRICTRANSITION IN RISE

SQ TO SQ ECCENTRIC TRANSITION

SQ TO SQ CONCENTRIC TRANSITION

SQ TO RND ECCENTRIC TRANSITION

SQ TO RND CONCENTRICTRANSITION

24x12

24x12

24x12

24"

24"

RND ELBOW 45°, RADIUS24"

RND ELBOW 90°, MITERED

RND ELBOW 90°, RADIUS

SQUARE ELBOW, NOTURNING VANES

RND DUCT ELEVATION CHANGE, UP

RND DUCT ELEVATION CHANGE,DOWN

NEW DUCTWORK WITH LINER

ROUND DUCT TAKE OFF

24"DUCTWORK DIMENSION LABEL(24" DIAMETER)

24x12DUCTWORK DIMENSION LABEL(24" WIDTH x 12" HEIGHT)

SQUARE DUCT TAKE OFF, SIDE

SQ DUCT ELEVATION CHANGE, 90°UP

SQ DUCT ELEVATION CHANGE, 90°DOWN

NEW RIGID DUCTWORK

EXISTING DUCTWORK TO BEDEMOLISHED

EXISTING DUCTWORK TO REMAIN

SQUARE ELBOW WITH DOUBLETHICKNESS TURNING VANES

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

M1.3 x

M1.4 x

M1.5 ROOF - MECHANICAL PLAN

M2.1 MECHANICAL SCHEDULES 1 OF 2

M2.2 MECHANICAL SCHEDULES 2 OF 2

2ND FLOOR - MECHANICAL PLAN

3RD FLOOR - MECHANICAL PLAN

4TH FLOOR - MECHANICAL PLAN

x

x

x

M3.1 MECHANICAL DETAILS 1 OF 2 x

xM3.2 MECHANICAL DETAILS 2 OF 2

Ø

M1.5 MECHANICAL ENLARGEMENT PLANS x

D W

RE

F.D

W

UP

RD4RD3 RD5 RD6

RD7

RD1 RD2RD8 RD9

CL

A0.7

A.07

A.06

A.05

12.5 11.8

VAN

~4'-6

"

DEPT

H

~4'-0

"D

EP

TH

5'-0"

DEPT

H

3'-6

"D

EP

TH

POOL

PTAC-11

PTAC-11

PTAC-11

PTAC-1

1

S

CFM2502410 A

(TYPICAL OF 8)

36x42 B

CCFM165

48" x 2 Slot

(TYPICAL OF 6)10"∅

CCFM165

48" x 2 Slot

(TYPICAL OF 3)10"∅

CCFM165

48" x 2 Slot

(TYPICAL OF 3)10"∅

12x12 12x12

32x2

0

CFM2002408 A

CFM1502408 ACFM 50

2406 A CFM1502408 A

CFM2502410 A24x12 D

24x12 D

12x24 D

16x1

2

12x12

CFM2502410 A

CFM1502408 A

CFM 502406 A

CFM1802408 A

CFM4002410 A

CFM4102410 A

12x12

24x24 D

CFM19524x12 D

12x24 D

CFM4102410 A

CCFM250

48" x 2 Slot10"∅

CCFM150

48" x 2 Slot10"∅

CFM1002406 A

CFM1502408 A

CCFM225

48" x 2 Slot10"∅

CCFM225

48" x 2 Slot10"∅

CCFM225

48" x 2 Slot10"∅

CCFM225

48" x 2 Slot10"∅

(TYPICAL OF 3)

10"∅

CCFM250

48" x 2 Slot10"∅

(TYPICAL OF 4)

CCFM250

48" x 2 Slot10"∅

(TYPICAL OF 4)

18x1

2

24x24 D

CCFM250

48" x 2 Slot10"∅

(TYPICAL OF 8)

24x24 D

14"∅CFM380

2412 A

(TYPICAL OF 5)

PTAC-11

PTAC-11

PTAC-1

1

PTAC-1

1

PTAC-11

PTAC-11

PTAC-1

1

CFM50024x24 D

CFM17524x12 D

CFM 7524x12 D

18x10

CFM 7524x12 D

CFM19524x24 D

CFM1502408 A

CFM19524x24 D

10"∅

8"∅

CFM1552408 A

375

10x10

10"∅

(TYPICAL OF 2)

10"∅

6"∅

10"∅

10"∅

10x8

6"∅

6"∅

6"∅

6"∅

6"∅

16x10

6"∅

8"∅

CFM1552408 A

8"∅

6"∅

6"∅

10"∅10"∅

8"∅

8"∅

S

S

S

S

EWH-17

EWH-27

10"∅

M

5

4

HP-8HP-7HP-6HP-5HP-4

HP-3HP-2HP-1

AHU-1 AHU-2

AHU-3 3

AHU-4 3

3

AHU-8

11

11

11 11

11

1111

11

8

9

EUH-110

S

S

S

FD

FD

FD

FD

FD

FD

FD FD FDFDFD

FD FD

FD

FD

FD

FD

FD

FDFD

FD

FD

FD

FD FD FD

FD

FSD FSD

FD FD

FDFD

FD

FD

FD

FD

FD

EWH-5

13

14

6"AFF

24x12 D(TYPICAL OF 2)

10"∅

8"∅C.O.

C.O.

C.O

.

C.O.

C.O.

16

18

19

20

20

20EDH-1

21

CFM1002406 A

11

11

1111 11

11

11

11

11

11

24x12 D(TYPICAL OF 2)

10"∅ 10"∅FD FD FD FD

AHU-7

AHU-6

AHU-5

3

3

12x10

FSD

FSDFSD

FSD

13

M1.1

1SCALE: 1/8"= 1'-0"

MECHANICAL - HVAC - 1ST FLOORAEED,Advanced Energy Engineering & Design, Inc

CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369

P.O. BOX 4934408 McCALLIE AVE

inc.

AEED JOB NO. 029-15

COPYRIGHT NOTICE

THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.

714

cher

ry s

treet

, cha

ttano

oga,

tenn

esse

e 37

402

p.42

3 63

4 08

06 f

.423

752

849

9 w

ww

.rive

r-st

-arc

hite

ctur

e.co

m

Release Date:Project No.:

3/31

/201

5 10

:17:

24 A

M

1205

5 G

ATE

WA

Y W

ES

T B

LVD

, EL

PA

SO

, TX

CO

UR

TY

AR

D B

Y M

AR

RIO

TT

ZAR

AG

OZA

HO

TEL

PA

RTN

ER

S, L

LC

MECHANICAL

M1.1

HVAC1ST FLOOR

a. FOR GENERAL HVAC NOTES SEE COVER SHEET. IN THE CASE OF CONFLICTING NOTES THE MOST STRINGENT OF THE TWO SHALL APPLYPER APPLICABLE JOB CODE.

b. ROUND DUCT RUNOUTS TO INDIVIDUAL DIFFUSERS TO BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED.

c. MAINTAIN 10 FT. (MIN.) SEPARATION BETWEEN OUTSIDE AIR INTAKES AND EXHAUST OR VENT OPENINGS.

d. EXTEND FULL SIZE CONDENSATE DRAIN LINE FROM EACH A/C UNIT AND TERMINATE AT FLOOR DRAIN, ROOF DRAIN, FRENCH DRAIN, OROTHER TERMINATION POINTS AS DIRECTED. TRAP AND VENT DRAIN LINE AT CONNECTION TO COIL.

e. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLING OVER 2000 CFM, MOUNTED IN SA DUCT (NFPA90A, 4-4.2), AND IN RA DUCT PRIOR TO EXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNIT SERVINGBUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S) TO STOP UNIT FAN IF SMOKE IS DETECTED.INTERLOCK WITH FIRE ALARM SYSTEM.

f. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZINGCALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.

g. COORDINATE EXTERIOR WALL LOUVER HEIGHTS WITH ARCHITECT TO PROVIDE A UNIFORM BUILDING APPEARANCE.

h. FOR ALL GUEST ROOM THERMOSTATS: REMOTE THERMOSTAT TO BE MOUNTED AT 48" ABOVE FINISH FLOOR IN ACCESSIBLEROOMS AND AT 54" ABOVE FINISH FLOOR IN NON-ACCESSIBLE ROOMS AT DEMISING WALL.

HVAC SHEET NOTES - UNREFERENCED

1

HVAC SHEET NOTES - REFERENCED

2

3

4

5

MOUNT CONDENSING UNIT AT GRADE ON 6" THICK RE-INFORCED CONCRETE PAD• PAD EXTENDS 6" ON EVERY SIDE OF UNIT.• MAINTAIN 36" CLEARANCE TO ELECTRICAL ACCESS PANELS.• ROUTE REFRIGERANT PIPING FROM CONDENSING UNIT UP IN EXTERIOR WALL (OR CHASE) AND TO CORRESPONDING A/C UNIT.• MINIMIZE PIPING EXPOSED ON EXTERIOR.• SEAL ALL PENETRATIONS TO EXTERIOR WEATHER TIGHT.• MAINTAIN MANUFACTURERS RECOMMENDED CLEARANCES BETWEEN UNITS.

FLOOR MOUNTED VERTICAL AC UNIT• MOUNT A/C UNIT ON 1/4" NEOPRENE ISOLATOR ON 24" HIGH RETURN AIR PLENUM AND CONFIGURE FOR BOTTOM RETURN.• CONNECT SA DUCT WITH FLEXIBLE CONNECTION.• ROUTE CONDENSATE DRAIN LINE TO SPILL IN FLOOR DRAIN SHOWN ON PLUMBING DRAWINGS• CONFIGURE UNIT IN SPACE TO ALLOW MFG SERVICE CLEARANCES & FILTER ACCESS.

DRYER VENTILATION SYSTEM• EXTEND 10" ROUND DRYER VENT FROM COMMERCIAL-TYPE CLOTHES DRYER TO COMMON LOUVER IN EXTERIOR WALL.• WRAP VENT WITH ZERO CLEARANCE FIRE RESISTANT DUCT WRAP EQUAL TO 3M FIRE BARRIER DUCT WRAP OR LIKE MATERIAL TO WITHSTAND

DRYER VENT HEAT.• DRYER VENTS TERMINATE AT 42x24 WALL LOUVER. SLEEVE AND SEAL PENETRATION WEATHER TIGHT.• LOUVER SIZED TO PROVIDE A FREE AREA OF 3.30ft2 TO ALLOW 2760CFM EXHAUST AT 850FPM. (920CFM PER DRYER x 3)• LOUVER BASED ON MANUFACTURER: UNITED ENERTECH MODEL: FL-D-4• VENTS TO BE SINGLE WALL GALVANIZED STEEL MIN. 0.0195 INCHES THICK.• INSTALL ESCUTCHEON PLATE AT PENETRATION OF ROOM SURFACES.• REVIEW MANUFACTURER'S VENTING REQUIREMENTS BEFORE COMMENCING WORK.• DRYER VENTS ARE TO HAVE SMOOTH INTERIOR SURFACES.• RIVET ALL CONNECTIONS & MAINTAIN CODE REQUIRED CLEARANCES.

PROVIDE ONE (1) 36x12 WALL LOUVER TO PROVIDE COMBUSTION/VENTILATION AIR FOR DRYERS.• MOUNT LOUVER 6" BELOW CEILING/ROOF STRUCTURE.• SLEEVE BUILDING PENETRATION AND SEAL WEATHER TIGHT.• LOUVER DESIGN BASED ON UNITED ENERTECH MODEL FL-D-4. PROVIDE MOTORIZED DAMPER INTERLOCKED WITH DRYERS FOR

SIMULTANEOUS OPERATION.• DAMPER SHALL ACTUATE FULLY OPEN UPON A MINIMUM OF ONE DRYER ACTIVATION.• EXACT LOUVER LOCATION IS TO BE COORDINATED WITH ARCHITECTURAL.• LOUVER IS SIZED TO ALLOW 135.0 SQinch (0.94 SQft) OF FREE AREA FOR LOUVER AS REQUIRED BY INT FUEL GAS CODE (304.6.2)

(1 SQinch OF FREE AREA PER 3,000 btuh OF COMBUSTION AT A TOTAL INPUT LOAD OF 405,000 btuh) (135,000 btuh PER DRYER X 3)• PROVIDE COMPLETE WITH BUG SCREEN.

PROVIDE SERVICEABLE LINT TRAP IN DRYER EXHAUST DUCT RISE. (TYPICAL OF 3)• LINT TRAP TO BE MAKE: LINT LASSO MODEL: LLA• PROVIDE COMPLETE WITH OVER PRESSURE MONITORING STATION TO INSURE

PROPER DRYER WORKING ORDER.

MOUNT WALL HEATER MINIMUM 6" A.F.F., UNIT TO BE INSTALLED RECESSED IN WALL.• SET UNIT THERMOSTAT TO ENERGIZE UPON A DETECTION OF SPACE TEMPERATURE TO BE DETERMINED BY OWNER.

OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 10"∅ SUPPLY• 10"∅ EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.

OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 30x12 SUPPLY• 24x14 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.

ELECTRIC UNIT HEATER• SUSPEND HEATER FROM STRUCTURE UTILIZING VIBRATION ISOLATION KIT.• MOUNT THERMOSTAT/CONTROLER IN ROOM AS SHOWN.• HEATER SHALL ENERGIZE UPON 45° SPACE DETECTION.

CABLE CONTROLLED BALANCING DAMPER (SEE DETAIL)• INSTALL PER MANUFACTURERS SUGGESTED GUIDELINES• TYPICAL OF ANY APPLICATION WHERE ACCESS TO MANUAL DAMPER IS RESTRICTED OR UNDESIRED.

2

MOUNT PACKAGED THROUGH-THE -WALL HEAT PUMP UNITS AS DIRECTED BY MANUFACTURER.• PROVIDE UNIT WITH ACCESSORIES LISTED IN SCHEDULE.• CONFIRM ALL ROUGH-IN DIMENSIONS AND REQUIREMENTS WITH GENERAL CONTRACTOR IN THE FIELD. ACCOUNT FOR SUB-BASE

HEIGHT WHEN DETERMINING A.F.F. INSTALLATION HEIGHT.• SEAL ALL WALL PENETRATIONS WEATHER TIGHT.• ROUTE CONDENSATE LINES PER PLUMBING PLANS.

6

7

8

9

10

11

SUSPEND EXHAUST FAN FROM STRUCTURE UTILIZING VIBRATION ISOLATION HANGERS.• ROUTE DUCT TO LOUVER/BRICK VENT IN EXTERIOR WALL.

12x12 LOUVER IN EXTERIOR WALL TO PROVIDE VENTILATION AIR INTAKE, SLEEVE AND SEAL BUILDINGPENETRATION WEATHER TIGHT.• LOUVER IS TO BE UNITED ENERTECH MODEL FL-D-4 SIZED TO PROVIDE A FREE AREA OF 0.32sqft.

FOR 50cfm.

MOUNT WALL HEATER MINIMUM 6" A.F.F., UNIT TO BE INSTALLED RECESSED IN WALL.• SET UNIT THERMOSTAT TO ENERGIZE UPON DETECTION OF 45°F SPACE TEMPERATURE &

DE-ENERGIZE AT 55°F.

12

13

14

DRYER VENT ASSEMBLY• 4" DRYER VENT OUT TO WALL CAP.• PROVIDE BOOSTER FAN AND ASSOCIATED LINT TRAP PRIOR TO FAN AT APPROXIMATELY THIS LOCATION.• INSTALL LINT TRAP & FAN IN A MANNER TO ALLOW SERVICE/CLEAN OUT.• BOOSTER FAN TO BE MANUFACTURER: FANTECH MODEL: DBF4XL.• FAN OPERATES VIA PRESSURE SWITCH TO RUN IN SEQUENCE WITH DRYER.

15

DISHWASHER HOOD ASSEMBLY• AT DISHWASHER EXHAUST HOOD (BY OTHERS), EXTEND 12"∅ DUCT FROM HOOD TO

ROOF MOUNTED EXHAUST FAN ON CURB, ROOF CURB TO OFFSET ROOF SLOPE.

AT RANGE HOOD ASSEMBLY, PROVIDED BY OTHERS• CONNECT 29x10 EXHAUST DUCT TO HOOD EXHAUST OPENING (3070 CFM).• CONNECT 3 - 28"x12" DUCTS TO HOOD MAKE UP AIR OPENINGS (2456 CFM TOTAL). PROVIDE MANUAL

VOLUME DAMPER IN EACH DROP FOR PROPER SYSTEM BALANCING.• EXTEND MAKEUP AIR DUCT TO CURB MOUNTED SUPPLY FAN ON ROOF, CURB TO OFFSET ROOF SLOPE.• EXTEND 40x12 EXHAUST DUCT TO ROOF MOUNTED EXHAUST FAN, CURB TO OFFSET ROOF SLOPE.• ALL HOOD DUCTWORK TO BE CONSTRUCTED OF STEEL NOT LESS THAN 0.030 INCH NO.22 GAGE IN

THICKNESS, STAINLESS STEEL NOT LESS THAN 0.024 INCH NO. 24 GAGE IN THICKNESS, COPPER SHEETSWEIGHING NOT LESS THAN 24 OUNCES PER SQUARE FOOT OR OF OTHER APPROVES MATERIAL GAGE.WELD ALL DUCT LIQUID TIGHT. WRAP DUCT WITH ZERO CLEARANCE FIRE RESISTANT DUCT WRAP EQUALTO 3M FIRE BARRIER DUCT WRAP.

• INTERLOCK KSF-1 AND KEF-1 WITH HOOD FOR SIMULTANEOUS OPERATION WHILE HOOD IS ENERGIZED.

• EXHAUST DUCT SHALL HAVE A (1/4")/(1'-0") SLOPE TOWARDS THE EXHAUST HOOD AT ALL TIMES.

GREASE CLEAN OUT DOORS (TYPICAL)• PROVIDE IN EXHAUST DUCT, SPACE NO MORE THAN 20 FEET APART AND NO MORE THAN

10 FEET FROM CHANGES IN DIRECTION.• CLEAN OUT DOOR SHALL NOT BE CLOSER THAN 1 INCH FROM THE EDGES OF DUCT AND BE

CONSTRUCTED OF MATERIALS TO MATCH GREASE DUCT IN GAGE AND TYPE.• DOOR GASKET AND SEALING MATERIALS SHALL BE RATED FOR NOT LESS THAN 1500°F.

EXHAUST DUCT CONTINUES TO ROOF MOUNTED EXHAUST FAN• SEE SHEET 2ND FLOOR FOR CONTINUATION.• EXHAUST DUCT FROM HOOD SHALL BE FREE OF FIRE DAMPER AS REQUIRED BY CODE.• WRAP DUCT WITH ZERO CLEARANCE FIRE RESISTANT DUCT WRAP EQUAL TO 3M FIRE

BARRIER DUCT WRAP.• DUCT SHALL HAVE A (1/4")/(1'-0") SLOPE TOWARDS THE EXHAUST HOOD AT ALL TIMES.

16

17

18

19

DUCT UP TO ROOF MOUNTED EQUIPMENT20

DUCT MOUNTED ELECTRIC HEATER• INSTALL IN A MANNER TO ALLOW SERVICE CLEARANCES.• HEATER SHALL ENERGIZE UPON A 40°F AIR STREAM TEMPERATURE.

21

UP

DN

UP

DN

KING

201QQ

203QQ

205KING - HEARING

207KING

209KING

211

KING

213KING

215QQ

219KING

221KING

223KING

225QQ

227

QQ - HEARING

229KING

231KING

233

QQ

202

ACC. KING

HEARING

204KING

206

KING

208

KING

210

ACC. QQ INLINE

SUITE

216

QQ

218QQ

220

KING

222

KING - HEARING

224QQ

226KING

228KING

230

QQ

217

912

ELECTRICAL

2005

LINEN

2004

KING

214

COMPUTER/

COMM ROOM

2006

ICE

2003

RD3 RD4 RD5 RD7

STAIR 1

S1STAIR 2

S2

ELEVATOR

LOBBY

2001CORRIDOR EAST

2000CORRIDOR WEST

2002CL

10.210.8

A.04

A.07

A.06

A.03

A.05

12.5

11.8

11.8

PTAC-11

PTAC-11

CFM10012x12 F

CFM15012x12 E

CFM12512x12 F

CFM15012x12 E

CFM 5012x12 E

TYPICAL OF ALLGUEST ROOMS

CFM 5512x12 F

TYPICAL OF ALL GUESTRESTROOM EXHAUST

HWFC-1

6

12x8

CFM 5012x12 E

TYPICAL OF ALLGUEST ROOMS

CFM 5512x12 F

TYPICAL OF ALL GUESTRESTROOM EXHAUST

HWFC-2

6PTAC-1

1

PTAC-11

PTAC-11

PTAC-1

1

PTAC-1

1

PTAC-11

PTAC-1

PTAC-1

1

PTAC-1

1

PTAC-1

1

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

FSD FSD

FSD FSD

FD FD

14x6

12x10

CD

CDCDCDCD

CDCDCDCDCDCD

CD

CD CD

2

3

5

FSD

FSD

FSD

FSD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FDFD FDFDFD

FDFD

FD FD

HW-CU-1 HW-CU-2

18x12

KEF-1DEF-1

KSF-1

1 PTAC-1 1

PTAC-11 PTAC-1 1

7

77

88

FD

CFM3002410 A

CFM2702410 A

M1.2

1SCALE: 1/8"= 1'-0"

MECHANICAL - HVAC - 2ND FLOOR

AEED,Advanced Energy Engineering & Design, Inc

CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369

P.O. BOX 4934408 McCALLIE AVE

inc.

AEED JOB NO. 029-15

COPYRIGHT NOTICE

THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.

714

cher

ry s

treet

, cha

ttano

oga,

tenn

esse

e 37

402

p.42

3 63

4 08

06 f

.423

752

849

9 w

ww

.rive

r-st

-arc

hite

ctur

e.co

m

Release Date:Project No.:

3/31

/201

5 10

:17:

24 A

M

1205

5 G

ATE

WA

Y W

ES

T B

LVD

, EL

PA

SO

, TX

CO

UR

TY

AR

D B

Y M

AR

RIO

TT

ZAR

AG

OZA

HO

TEL

PA

RTN

ER

S, L

LC

MECHANICAL

M1.2

HVAC2ND FLOOR

a. FOR GENERAL HVAC NOTES SEE COVER SHEET. IN THE CASE OF CONFLICTING NOTES THE MOST STRINGENT OF THE TWO SHALL APPLYPER APPLICABLE JOB CODE.

b. ROUND DUCT RUNOUTS TO INDIVIDUAL DIFFUSERS TO BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED.

c. MAINTAIN 10 FT. (MIN.) SEPARATION BETWEEN OUTSIDE AIR INTAKES AND EXHAUST OR VENT OPENINGS.

d. EXTEND FULL SIZE CONDENSATE DRAIN LINE FROM EACH A/C UNIT AND TERMINATE AT FLOOR DRAIN, ROOF DRAIN, FRENCH DRAIN, OROTHER TERMINATION POINTS AS DIRECTED. TRAP AND VENT DRAIN LINE AT CONNECTION TO COIL.

e. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLING OVER 2000 CFM, MOUNTED IN SA DUCT (NFPA90A, 4-4.2), AND IN RA DUCT PRIOR TO EXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNIT SERVINGBUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S) TO STOP UNIT FAN IF SMOKE IS DETECTED.INTERLOCK WITH FIRE ALARM SYSTEM.

f. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZINGCALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.

g. COORDINATE EXTERIOR WALL LOUVER HEIGHTS WITH ARCHITECT TO PROVIDE A UNIFORM BUILDING APPEARANCE.

h. FOR ALL GUEST ROOM THERMOSTATS: REMOTE THERMOSTAT TO BE MOUNTED AT 48" ABOVE FINISH FLOOR IN ACCESSIBLEROOMS AND AT 54" ABOVE FINISH FLOOR IN NON-ACCESSIBLE ROOMS AT DEMISING WALL.

HVAC SHEET NOTES - UNREFERENCED

1

HVAC SHEET NOTES - REFERENCED

OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 24x20 SUPPLY• 22x20 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.

MOUNT PACKAGED THROUGH-THE -WALL HEAT PUMP UNITS AS DIRECTED BY MANUFACTURER.• PROVIDE UNIT WITH ACCESSORIES LISTED IN SCHEDULE.• CONFIRM ALL ROUGH-IN DIMENSIONS AND REQUIREMENTS WITH GENERAL CONTRACTOR IN THE FIELD. ACCOUNT FOR SUB-BASE

HEIGHT WHEN DETERMINING A.F.F. INSTALLATION HEIGHT.• SEAL ALL WALL PENETRATIONS WEATHER TIGHT.• ROUTE CONDENSATE LINES PER PLUMBING PLANS.

2

OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 24x12 SUPPLY• 24x12 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.

3

DUCT MAINS ROUTED ABOVE RATED CEILING STRUCTURE• COORDINATE DUCT ROUTING WITH JOIST WEBBING, MODIFY AS REQUIRED.

4

EXHAUST AND SUPPLY BRANCH DUCTS DOWN FROM BOTTOM OF MAIN DUCTS IN FIRE RATED FLOOR SYSTEM ABOVE.• PROVIDE FIRE DAMPER AT RATING PENETRATION. (TYPICAL)

5

6 INDOOR WALL MOUNT AC UNIT• MOUNT AT 6'-0" A.F.F. AND IN A MANNER TO NOT INTERFERE WITH ELECTRICAL EQUIPMENT.• SEE PLUMBING PLANS FOR PUMPED CONDENSATE PIPE ROUTING.

7 CURB MOUNTED FAN• INSTALL FAN LEVEL ON ROOF CURB, CURB IS TO OFFSET ANY ROOF SLOPE.• INTERLOCK FAN WITH ASSOCIATED KITCHEN HOOD FOR SIMULTANEOUS OPERATION.

CONDENSING UNITS• MOUNT UNITS LEVEL ON METAL EQUIPMENT RAILS.• RAILS ARE TO BE CONSTRUCTED OF A MATERIAL TO WITHSTAND WEATHERING/RUSTING• ROUTE REFRIGERANT LINES TO CORRESPONDING INDOOR UNIT UTILIZING THE SHORTEST RUN POSSIBLE WHILE

MAINTAINING PROPER MECHANICAL STANDARDS.• SUPPORT REFRIGERANT LINES OFF ROOF WITH POLYMER BLOCKS.• REFRIGERANT LINES ARE TO PENETRATE BUILDING THROUGH CURBED PITCH POCKET SEALED WEATHER TIGHT.

8

DN UP DNUP

KING

333KING

331QQ - HEARING

329 QQ

327

KING

325KING

323KING

321

QQ

319ACC. QQ

317

KING

315KING - WIDE

313

KING

311KING

309KING - HEARING

307QQ

305QQ

303

KING

301

QQ - HEARING

302ACC. KING

304

KING

306KING

308KING

310KING

314

ACC. QQ INLINE

SUITE

316

QQ

318

QQ

320

KING

322KING - HEARING

324

QQ

326KING

328KING

330

ELECTRICAL

3005

LINEN

3004

COMPUTER/

COMM ROOM

3006

ICE

3003

ELEVATOR

LOBBY

3001COORIDOR EAST

3000CORRIDOR WEST

3002

STAIR 2

S2

STAIR 1

S1

KING

314

TYP. TYP.

TYP.

TYP.

EWH-47

EWH-37

PTAC-11

PTAC-1

1

CFM10012x12 F

CFM15012x12 E

CFM 5012x12 E

TYPICAL OF ALLGUEST ROOMS

CFM 5512x12 F

TYPICAL OF ALL GUESTRESTROOM EXHAUST

HWFC-3

6

12x8

CFM 5012x12 E

TYPICAL OF ALLGUEST ROOMS

CFM 5512x12 F

TYPICAL OF ALL GUESTRESTROOM EXHAUST

HWFC-4

6PTAC-1

1

PTAC-1

1

PTAC-1

1

PTAC-11

PTAC-1

1

PTAC-1

1

PTAC-1

1

PTAC-1

1

PTAC-1

1

PTAC-1

1PTAC-1

1PTAC-1

1

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

FSD FSD

FSD FSD

FD FD

14x6

12x10

CD

CDCDCD

CDCD

CD CD

2

3

5

FSD

FSD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD FDFDFD

FDFD

FD FD

CFM15012x12 E

CFM12512x12 F

CD

FSD

FSD FD

18x12

FD

CFM3002410 A

CFM2702410 A

M1.3

1SCALE: 1/8"= 1'-0"

MECHANICAL - HVAC - 3RD FLOOR

AEED,Advanced Energy Engineering & Design, Inc

CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369

P.O. BOX 4934408 McCALLIE AVE

inc.

AEED JOB NO. 029-15

COPYRIGHT NOTICE

THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.

714

cher

ry s

treet

, cha

ttano

oga,

tenn

esse

e 37

402

p.42

3 63

4 08

06 f

.423

752

849

9 w

ww

.rive

r-st

-arc

hite

ctur

e.co

m

Release Date:Project No.:

3/31

/201

5 10

:17:

24 A

M

1205

5 G

ATE

WA

Y W

ES

T B

LVD

, EL

PA

SO

, TX

CO

UR

TY

AR

D B

Y M

AR

RIO

TT

ZAR

AG

OZA

HO

TEL

PA

RTN

ER

S, L

LC

MECHANICAL

M1.3

HVAC3RD FLOOR

a. FOR GENERAL HVAC NOTES SEE COVER SHEET. IN THE CASE OF CONFLICTING NOTES THE MOST STRINGENT OF THE TWO SHALL APPLYPER APPLICABLE JOB CODE.

b. ROUND DUCT RUNOUTS TO INDIVIDUAL DIFFUSERS TO BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED.

c. MAINTAIN 10 FT. (MIN.) SEPARATION BETWEEN OUTSIDE AIR INTAKES AND EXHAUST OR VENT OPENINGS.

d. EXTEND FULL SIZE CONDENSATE DRAIN LINE FROM EACH A/C UNIT AND TERMINATE AT FLOOR DRAIN, ROOF DRAIN, FRENCH DRAIN, OROTHER TERMINATION POINTS AS DIRECTED. TRAP AND VENT DRAIN LINE AT CONNECTION TO COIL.

e. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLING OVER 2000 CFM, MOUNTED IN SA DUCT (NFPA90A, 4-4.2), AND IN RA DUCT PRIOR TO EXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNIT SERVINGBUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S) TO STOP UNIT FAN IF SMOKE IS DETECTED.INTERLOCK WITH FIRE ALARM SYSTEM.

f. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZINGCALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.

g. COORDINATE EXTERIOR WALL LOUVER HEIGHTS WITH ARCHITECT TO PROVIDE A UNIFORM BUILDING APPEARANCE.

h. FOR ALL GUEST ROOM THERMOSTATS: REMOTE THERMOSTAT TO BE MOUNTED AT 48" ABOVE FINISH FLOOR IN ACCESSIBLEROOMS AND AT 54" ABOVE FINISH FLOOR IN NON-ACCESSIBLE ROOMS AT DEMISING WALL.

HVAC SHEET NOTES - UNREFERENCED

1

HVAC SHEET NOTES - REFERENCED

OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 24x24 SUPPLY• 24x24 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.

MOUNT PACKAGED THROUGH-THE -WALL HEAT PUMP UNITS AS DIRECTED BY MANUFACTURER.• PROVIDE UNIT WITH ACCESSORIES LISTED IN SCHEDULE.• CONFIRM ALL ROUGH-IN DIMENSIONS AND REQUIREMENTS WITH GENERAL CONTRACTOR IN THE FIELD. ACCOUNT FOR SUB-BASE

HEIGHT WHEN DETERMINING A.F.F. INSTALLATION HEIGHT.• SEAL ALL WALL PENETRATIONS WEATHER TIGHT.• ROUTE CONDENSATE LINES PER PLUMBING PLANS.

2

3

DUCT MAINS ROUTED ABOVE RATED CEILING STRUCTURE• COORDINATE DUCT ROUTING WITH JOIST WEBBING, MODIFY AS REQUIRED.

4

EXHAUST AND SUPPLY BRANCH DUCTS DOWN FROM BOTTOM OF MAIN DUCTS IN FIRE RATED FLOOR SYSTEM ABOVE.• PROVIDE FIRE DAMPER AT RATING PENETRATION. (TYPICAL)

5

6

7

INDOOR WALL MOUNT AC UNIT• MOUNT AT 6'-0" A.F.F. AND IN A MANNER TO NOT INTERFERE WITH ELECTRICAL EQUIPMENT.• SEE PLUMBING PLANS FOR PUMPED CONDENSATE PIPE ROUTING.

MOUNT WALL HEATER MINIMUM 6" A.F.F., UNIT TO BE INSTALLED RECESSED IN WALL.• SET UNIT THERMOSTAT TO ENERGIZE UPON A DETECTION OF SPACE TEMPERATURE TO BE DETERMINED BY OWNER.

OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 36x12 SUPPLY• 36x12 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.

DNDN

KING

433KING

431

QQ

429QQ

427KING

425KING

423KING

421QQ

419QQ

417

KING

415KING

413

KING

411KING

409KING

407QQ

405QQ

403KING

401

QQ - HEARING

402QQ

404KING

406KING

408

KING

410

QQ INLINE SUITE

- HEARING

416

QQ

418QQ

420KING

422KING

424QQ

426KING

428KING

430

ELECTRICAL

4005

LINEN

4004

COMPUTER/

COMM ROOM

4006

ELEVATOR

LOBBY

4001 CORRIDOR EAST

4000

ICE

4003

CORRIDOR WEST

4002

STAIR 2

S2

STAIR 1

S1

KING

414

TYP. TYP.

TYP.

TYP.

A0.7

ROOF LADDER

PTAC-11

PTAC-11

CFM3002410 A

CFM15012x12 E

CFM 5012x12 E

TYPICAL OF ALLGUEST ROOMS

CFM 5512x12 F

TYPICAL OF ALL GUESTRESTROOM EXHAUST

HWFC-5

6

CFM2702410 A

12x8

CFM 5012x12 E

TYPICAL OF ALLGUEST ROOMS

CFM 5512x12 F

TYPICAL OF ALL GUESTRESTROOM EXHAUST

HWFC-6

6PTAC-1

1

PTAC-11

PTAC-11

PTAC-1

1

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-1

1

PTAC-1

1

PTAC-1

1

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

PTAC-11

FSD FSD

FSD FSD

FD FD

14x6

12x10

CD

CDCDCD

CD

CD

CD CD

2

3

5

FSD

FSD

FD

FD

FD

FD

FD FD

FD

FD

FDFD FDFDFD

FDFD

FD FD

CFM15012x12 E

CFM12512x12 F

CD

FSD

FSD FD

18x12

FD

M1.4

1SCALE: 1/8"= 1'-0"

MECHANICAL - HVAC - 4TH FLOOR

AEED,Advanced Energy Engineering & Design, Inc

CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369

P.O. BOX 4934408 McCALLIE AVE

inc.

AEED JOB NO. 029-15

COPYRIGHT NOTICE

THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.

714

cher

ry s

treet

, cha

ttano

oga,

tenn

esse

e 37

402

p.42

3 63

4 08

06 f

.423

752

849

9 w

ww

.rive

r-st

-arc

hite

ctur

e.co

m

Release Date:Project No.:

3/31

/201

5 10

:17:

24 A

M

1205

5 G

ATE

WA

Y W

ES

T B

LVD

, EL

PA

SO

, TX

CO

UR

TY

AR

D B

Y M

AR

RIO

TT

ZAR

AG

OZA

HO

TEL

PA

RTN

ER

S, L

LC

MECHANICAL

M1.4

HVAC4TH FLOOR

a. FOR GENERAL HVAC NOTES SEE COVER SHEET. IN THE CASE OF CONFLICTING NOTES THE MOST STRINGENT OF THE TWO SHALL APPLYPER APPLICABLE JOB CODE.

b. ROUND DUCT RUNOUTS TO INDIVIDUAL DIFFUSERS TO BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED.

c. MAINTAIN 10 FT. (MIN.) SEPARATION BETWEEN OUTSIDE AIR INTAKES AND EXHAUST OR VENT OPENINGS.

d. EXTEND FULL SIZE CONDENSATE DRAIN LINE FROM EACH A/C UNIT AND TERMINATE AT FLOOR DRAIN, ROOF DRAIN, FRENCH DRAIN, OROTHER TERMINATION POINTS AS DIRECTED. TRAP AND VENT DRAIN LINE AT CONNECTION TO COIL.

e. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLING OVER 2000 CFM, MOUNTED IN SA DUCT (NFPA90A, 4-4.2), AND IN RA DUCT PRIOR TO EXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNIT SERVINGBUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S) TO STOP UNIT FAN IF SMOKE IS DETECTED.INTERLOCK WITH FIRE ALARM SYSTEM.

f. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZINGCALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.

g. COORDINATE EXTERIOR WALL LOUVER HEIGHTS WITH ARCHITECT TO PROVIDE A UNIFORM BUILDING APPEARANCE.

h. FOR ALL GUEST ROOM THERMOSTATS: REMOTE THERMOSTAT TO BE MOUNTED AT 48" ABOVE FINISH FLOOR IN ACCESSIBLEROOMS AND AT 54" ABOVE FINISH FLOOR IN NON-ACCESSIBLE ROOMS AT DEMISING WALL.

HVAC SHEET NOTES - UNREFERENCED

1

HVAC SHEET NOTES - REFERENCED

OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 26x26 SUPPLY• 26x26 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.

MOUNT PACKAGED THROUGH-THE -WALL HEAT PUMP UNITS AS DIRECTED BY MANUFACTURER.• PROVIDE UNIT WITH ACCESSORIES LISTED IN SCHEDULE.• CONFIRM ALL ROUGH-IN DIMENSIONS AND REQUIREMENTS WITH GENERAL CONTRACTOR IN THE FIELD. ACCOUNT FOR SUB-BASE

HEIGHT WHEN DETERMINING A.F.F. INSTALLATION HEIGHT.• SEAL ALL WALL PENETRATIONS WEATHER TIGHT.• ROUTE CONDENSATE LINES PER PLUMBING PLANS.

2

OUTDOOR AIR SUPPLY AND EXHAUST DUCTS FROM FLOOR ABOVE.• 42x12 SUPPLY• 40x12 EXHAUST• PROVIDE COMBINATION FIRE/SMOKE DAMPER AT CHASE PENETRATION POINTS.

3

DUCT MAINS ROUTED ABOVE RATED CEILING STRUCTURE• COORDINATE DUCT ROUTING WITH JOIST WEBBING, MODIFY AS REQUIRED.

4

EXHAUST AND SUPPLY BRANCH DUCTS DOWN FROM BOTTOM OF MAIN DUCTS IN FIRE RATED FLOOR SYSTEM ABOVE.• PROVIDE FIRE DAMPER AT RATING PENETRATION. (TYPICAL)

5

6 INDOOR WALL MOUNT AC UNIT• MOUNT AT 6'-0" A.F.F. AND IN A MANNER TO NOT INTERFERE WITH ELECTRICAL EQUIPMENT.• SEE PLUMBING PLANS FOR PUMPED CONDENSATE PIPE ROUTING.

RD1 RD2 RD3 RD4 RD5 RD6 RD7 RD8 RD9

OF1 OF2 OF3 OF4 OF5 OF6 OF7 OF8 OF9

M MMAU-2

2

HW-CU-3

HW-CU-4

HW-CU-5

HW-CU-6

28x2

0

SDT

SDT

SDT

SDT

M1.5

1SCALE: 1/8"= 1'-0"

MECHANICAL - HVAC - ROOF

AEED,Advanced Energy Engineering & Design, Inc

CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369

P.O. BOX 4934408 McCALLIE AVE

inc.

AEED JOB NO. 029-15

COPYRIGHT NOTICE

THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.

714

cher

ry s

treet

, cha

ttano

oga,

tenn

esse

e 37

402

p.42

3 63

4 08

06 f

.423

752

849

9 w

ww

.rive

r-st

-arc

hite

ctur

e.co

m

Release Date:Project No.:

3/31

/201

5 10

:17:

24 A

M

1205

5 G

ATE

WA

Y W

ES

T B

LVD

, EL

PA

SO

, TX

CO

UR

TY

AR

D B

Y M

AR

RIO

TT

ZAR

AG

OZA

HO

TEL

PA

RTN

ER

S, L

LC

MECHANICAL

M1.5

HVACROOF

a. FOR GENERAL HVAC NOTES SEE COVER SHEET. IN THE CASE OF CONFLICTING NOTES THE MOST STRINGENT OF THE TWO SHALL APPLYPER APPLICABLE JOB CODE.

b. ROUND DUCT RUNOUTS TO INDIVIDUAL DIFFUSERS TO BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED.

c. MAINTAIN 10 FT. (MIN.) SEPARATION BETWEEN OUTSIDE AIR INTAKES AND EXHAUST OR VENT OPENINGS.

d. EXTEND FULL SIZE CONDENSATE DRAIN LINE FROM EACH A/C UNIT AND TERMINATE AT FLOOR DRAIN, ROOF DRAIN, FRENCH DRAIN, OROTHER TERMINATION POINTS AS DIRECTED. TRAP AND VENT DRAIN LINE AT CONNECTION TO COIL.

e. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLING OVER 2000 CFM, MOUNTED IN SA DUCT (NFPA90A, 4-4.2), AND IN RA DUCT PRIOR TO EXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNIT SERVINGBUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S) TO STOP UNIT FAN IF SMOKE IS DETECTED.INTERLOCK WITH FIRE ALARM SYSTEM.

f. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZINGCALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.

g. COORDINATE EXTERIOR WALL LOUVER HEIGHTS WITH ARCHITECT TO PROVIDE A UNIFORM BUILDING APPEARANCE.

h. FOR ALL GUEST ROOM THERMOSTATS: REMOTE THERMOSTAT TO BE MOUNTED AT 48" ABOVE FINISH FLOOR IN ACCESSIBLEROOMS AND AT 54" ABOVE FINISH FLOOR IN NON-ACCESSIBLE ROOMS AT DEMISING WALL.

HVAC SHEET NOTES - UNREFERENCED

1

HVAC SHEET NOTES - REFERENCED

2

68x16 LOUVER WITH AT LEAST 3 SQUARE FEET OF FREE AREA FOR EACH CAR FOR ELEVATOR SHAFT RELIEF• COORDINATE LOCATION WITH ARCHITECTURAL.• MODEL BASED ON RUSKIN ELC445D.• PROVIDE LOUVERS WITH MOTORIZED DAMPERS TIED INTO THE FIRE ALARM SYSTEM.• SLEEVE AND SEAL AROUND LOUVER WEATHER TIGHT• PROVIDE COMPLETE WITH BUG SCREEN

3

4

VERTICAL SUPPLY / EXHAUST DUCTS DOWN INTO CHASE THROUGH ROOF CURB.• OFFSET/TRANSITION DUCTWORK IN CURB TO ALLOW PROPER ENTRY INTO CHASE

MOUNT MAU UNIT AS SHOWN ON FACTORY ROOF CURB (MIN. 24" HIGH).• MAINTAIN 36" CLEARANCE TO ELECTRICAL ACCESS PANELS.• SUPPLY DUCT IS TO BE SIDE DISCHARGE FROM CURB, ROUTE TO CURBED ROOF PENETRATION AS SHOWN.• EXHAUST DUCT IS TO BE SIDE DISCHARGE FROM CURB, ROUTE TO CURBED ROOF PENETRATION AS SHOWN.• ROUTE FULL SIZE CONDENSATE DRAIN TO SPILL ON ROOF. SLOPE CONDENSATE LINE 1/8" AWAY FROM UNIT.• PROVIDE CURB EXTENSION AS NEEDED TO TRANSITIONS DUCTS INTO CHASE BELOW.• INSTALL FIRE/SMOKE DETECTORS IN SUPPLY AND EXHAUST AIR STREAMS AS REQUIRED BY CODE/NFPA. DETECTORS SUPPLIED BY MECHANICAL

CONTRACTOR AND INSTALLED/WRIED BY ELECTRICAL CONTRACTOR.

CURB MOUNTED GRAVITY RELIEF ON TOP OF LINEN CHUTE• MOUNT CAP LEVEL ON ROOF CURB TO OFFSET ANY SLOPE• MAP MFG: GREENHECK MODEL: GRSR-24• PROVIDE COMPLETE WITH BUG SCREEN• 10'-0"∅ CLEARANCE TO FRESH AIR INTAKE RADIUS SHOWN

5 CONDENSING UNITS• MOUNT UNITS LEVEL ON METAL EQUIPMENT RAILS.• RAILS ARE TO BE CONSTRUCTED OF A MATERIAL TO WITHSTAND WEATHERING/RUSTING• ROUTE REFRIGERANT LINES TO CORRESPONDING INDOOR UNIT UTILIZING THE SHORTEST RUN POSSIBLE WHILE MAINTAINING PROPER

MECHANICAL STANDARDS.• SUPPORT REFRIGERANT LINES OFF ROOF WITH POLYMER BLOCKS.• REFRIGERANT LINES ARE TO PENETRATE BUILDING THROUGH CURBED PITCH POCKET SEALED WEATHER TIGHT.

6 EXPOSED EXHAUST DUCT ON ROOF.• DUCT EXITS ROOF CURB HORIZONTALLY THROUGH CUSTOM OPENING.• SUPPORT DUCT OFF ROOF WITH STEEL FRAME SPACED A MINIMUM 48" ON CENTER AND AT EACH ELBOW.• SEE DUCT SUPPORTS OFF ROOF DETAIL FOR CLARITY.• DUCT SHALL BE INSULATED WITH A MINERAL-FIBERBOARD, 3 INCHES THICK, 3-LB/CU. FT. NOMINAL DENSITY. INSTALL

WEATHER RESISTANT JACKET OVER INSULATION MATERIAL. FOR INSULATION WITH FACTORY-APPLIED JACKET, INSTALL THEFIELD-APPLIED JACKET OVER THE FACTORY-APPLIED JACKET. DUCTS AND PLENUMS, EXPOSED, UP TO 48 INCHES IN DIAMETEROR WITH FLAT SURFACES UP TO 72 INCHES: ALUMINUM, SMOOTH MINIMUM 0.020 INCHES THICK.

• DUCT ENTERS TOP OF CHASE VIA CURBED POCKET SEALED WEATHER TIGHT, TRANSITION DUCT AS REQUIRED TO MATCHDROP IN CHASE PRIOR TO CHASE PENETRATION.

RD7

36x42 B

32x2

0

26x1

2

10"∅

26x1

4

AHU-42

AHU-8

EUH-111

FD

FD

FD

FD

FD

FD

FD FD FD FD

AHU-7

AHU-6

AHU-5

3

3

3

3

14x1

0

26x12

26x12

14x12

16x12

SDT

SDT

SDT

SDT

SDT

SDT

SDT

SDT

SDT

2

SDT

4

RD4RD3

A0.7

22x14

20x20

24x24 D

22x1

4

20x20

18x1

414

x14

CFM3802412 A

(TYPICAL OF 5)

10"∅6"∅

AHU-1

FD FD FD

22x1

4

40x1

2

30x12

C.O.

C.O.

C.O.

C.O.

6

7

8

9

EDH-1

10

CFM1002406 A

FD

24x24 D

AHU-3AHU-2

14x10

10x1010"∅

FD

20x20

FD FD

24x24 D

FD

FD

14"∅

5

SDT

SDT

SDT

SDT

SDT

SDT

KEF-1DEF-1

KSF-113

C.O.

9

9

1313

S

M1.6

1SCALE: 1/4"= 1'-0"

MECHANICAL - ENLARGEMENT PLAN A

AEED,Advanced Energy Engineering & Design, Inc

CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369

P.O. BOX 4934408 McCALLIE AVE

inc.

AEED JOB NO. 029-15

COPYRIGHT NOTICE

THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.

714

cher

ry s

treet

, cha

ttano

oga,

tenn

esse

e 37

402

p.42

3 63

4 08

06 f

.423

752

849

9 w

ww

.rive

r-st

-arc

hite

ctur

e.co

m

Release Date:Project No.:

3/31

/201

5 10

:17:

24 A

M

1205

5 G

ATE

WA

Y W

ES

T B

LVD

, EL

PA

SO

, TX

CO

UR

TY

AR

D B

Y M

AR

RIO

TT

ZAR

AG

OZA

HO

TEL

PA

RTN

ER

S, L

LC

MECHANICAL

M1.6

ENLARGEMENTPLANS

a. FOR GENERAL HVAC NOTES SEE COVER SHEET. IN THE CASE OF CONFLICTING NOTES THE MOST STRINGENT OF THE TWO SHALL APPLYPER APPLICABLE JOB CODE.

b. ROUND DUCT RUNOUTS TO INDIVIDUAL DIFFUSERS TO BE SAME SIZE AS DIFFUSER NECK UNLESS NOTED.

c. MAINTAIN 10 FT. (MIN.) SEPARATION BETWEEN OUTSIDE AIR INTAKES AND EXHAUST OR VENT OPENINGS.

d. EXTEND FULL SIZE CONDENSATE DRAIN LINE FROM EACH A/C UNIT AND TERMINATE AT FLOOR DRAIN, ROOF DRAIN, FRENCH DRAIN, OROTHER TERMINATION POINTS AS DIRECTED. TRAP AND VENT DRAIN LINE AT CONNECTION TO COIL.

e. INSTALL SMOKE DETECTORS (PROVIDED BY ELECTRICAL) AT EACH A/C UNIT HANDLING OVER 2000 CFM, MOUNTED IN SA DUCT (NFPA90A, 4-4.2), AND IN RA DUCT PRIOR TO EXHAUST OR MIXING (SMC 406.1). ALSO INSTALL SMOKE DETECTOR AT EACH A/C UNIT SERVINGBUILDING EGRESS (REGARDLESS OF SIZE), MOUNTED IN SA DUCT. DETECTOR(S) TO STOP UNIT FAN IF SMOKE IS DETECTED.INTERLOCK WITH FIRE ALARM SYSTEM.

f. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZINGCALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.

g. COORDINATE EXTERIOR WALL LOUVER HEIGHTS WITH ARCHITECT TO PROVIDE A UNIFORM BUILDING APPEARANCE.

HVAC SHEET NOTES - UNREFERENCED

M1.6

2SCALE: 1/4"= 1'-0"

MECHANICAL - ENLARGEMENT PLAN

1

HVAC SHEET NOTES - REFERENCED

2

3

4

5

FLOOR MOUNTED VERTICAL AC UNIT• MOUNT A/C UNIT ON 1/4" NEOPRENE ISOLATOR ON 24" HIGH RETURN AIR PLENUM AND CONFIGURE FOR BOTTOM RETURN.• CONNECT SA DUCT WITH FLEXIBLE CONNECTION.• ROUTE CONDENSATE DRAIN LINE TO SPILL IN FLOOR DRAIN SHOWN ON PLUMBING DRAWINGS• CONFIGURE UNIT IN SPACE TO ALLOW MFG SERVICE CLEARANCES & FILTER ACCESS.• CONFIGURE UNIT FOR BOTTOM RETURN WITH TOP DISCHARGE.

ELECTRIC UNIT HEATER• SUSPEND HEATER FROM STRUCTURE UTILIZING VIBRATION ISOLATION KIT.• MOUNT THERMOSTAT/CONTROLER IN ROOM AS SHOWN.• HEATER SHALL ENERGIZE UPON 45° SPACE DETECTION.

11

12 DRYER VENT ASSEMBLY• 4" DRYER VENT OUT TO WALL CAP.• PROVIDE BOOSTER FAN AND ASSOCIATED LINT TRAP PRIOR TO FAN AT APPROXIMATELY THIS LOCATION.• INSTALL LINT TRAP & FAN IN A MANNER TO ALLOW SERVICE/CLEAN OUT.• BOOSTER FAN TO BE MANUFACTURER: FANTECH MODEL: DBF4XL.• FAN OPERATES VIA PRESSURE SWITCH TO RUN IN SEQUENCE WITH DRYER.

DISHWASHER HOOD ASSEMBLY• AT DISHWASHER EXHAUST HOOD (BY OTHERS), EXTEND 12"∅ DUCT FROM HOOD TO

ROOF MOUNTED EXHAUST FAN ON CURB, ROOF CURB TO OFFSET ROOF SLOPE.

AT RANGE HOOD ASSEMBLY, PROVIDED BY OTHERS• CONNECT 29x10 EXHAUST DUCT TO HOOD EXHAUST OPENING (3070 CFM).• CONNECT 3 - 28"x12" DUCTS TO HOOD MAKE UP AIR OPENINGS (2456 CFM TOTAL). PROVIDE MANUAL

VOLUME DAMPER IN EACH DROP FOR PROPER SYSTEM BALANCING.• EXTEND MAKEUP AIR DUCT TO CURB MOUNTED SUPPLY FAN ON ROOF, CURB TO OFFSET ROOF SLOPE.• EXTEND 40x12 EXHAUST DUCT TO ROOF MOUNTED EXHAUST FAN, CURB TO OFFSET ROOF SLOPE.• ALL HOOD DUCTWORK TO BE CONSTRUCTED OF STEEL NOT LESS THAN 0.030 INCH NO.22 GAGE IN

THICKNESS, STAINLESS STEEL NOT LESS THAN 0.024 INCH NO. 24 GAGE IN THICKNESS, COPPER SHEETSWEIGHING NOT LESS THAN 24 OUNCES PER SQUARE FOOT OR OF OTHER APPROVES MATERIAL GAGE.WELD ALL DUCT LIQUID TIGHT. WRAP DUCT WITH ZERO CLEARANCE FIRE RESISTANT DUCT WRAP EQUALTO 3M FIRE BARRIER DUCT WRAP.

• INTERLOCK KSF-1 AND KEF-1 WITH HOOD FOR SIMULTANEOUS OPERATION WHILE HOOD IS ENERGIZED.

• EXHAUST DUCT SHALL HAVE A (1/4")/(1'-0") SLOPE TOWARDS THE EXHAUST HOOD AT ALL TIMES.

GREASE CLEAN OUT DOORS (TYPICAL)• PROVIDE IN EXHAUST DUCT, SPACE NO MORE THAN 20 FEET APART AND NO MORE THAN

10 FEET FROM CHANGES IN DIRECTION.• CLEAN OUT DOOR SHALL NOT BE CLOSER THAN 1 INCH FROM THE EDGES OF DUCT AND BE

CONSTRUCTED OF MATERIALS TO MATCH GREASE DUCT IN GAGE AND TYPE.• DOOR GASKET AND SEALING MATERIALS SHALL BE RATED FOR NOT LESS THAN 1500°F.

EXHAUST DUCT CONTINUES TO ROOF MOUNTED EXHAUST FAN• SEE SHEET 2ND FLOOR FOR CONTINUATION.• EXHAUST DUCT FROM HOOD SHALL BE FREE OF FIRE DAMPER AS REQUIRED BY CODE.• WRAP DUCT WITH ZERO CLEARANCE FIRE RESISTANT DUCT WRAP EQUAL TO 3M FIRE

BARRIER DUCT WRAP.• DUCT SHALL HAVE A (1/4")/(1'-0") SLOPE TOWARDS THE EXHAUST HOOD AT ALL TIMES.

DUCT UP TO ROOF MOUNTED EQUIPMENT

DUCT MOUNTED ELECTRIC HEATER• INSTALL IN A MANNER TO ALLOW SERVICE CLEARANCES.• HEATER SHALL ENERGIZE UPON A 40°F AIR STREAM TEMPERATURE.

DUCT MOUNTED SMOKE DETECTOR• PROVIDE DUCT MOUNTED SMOKE DETECTOR IN RETURN DUCT PRIOR TO MIXING WITH OUTDOOR AIR.• PROVIDE DUCT MOUNTED SMOKE DETECTOR IN SUPPLY PRIOR TO ANY TAKE OFFS

PROVIDE BALANCING DAMPERS IN RETURN AND OUTDOOR AIR DUCTS AS SHOWNTO ALLOW PROPER BALANCING OF RETURN/OUTDOOR AIR.

OUTDOOR AIR DUCT, SEE FIRST FLOOR MECHANICAL PLAN FOR CONTINUATION

6

7

8

9

10

13 ROOF MOUNTED EQUIPMENT SHOWN FOR CLARITY

14 WALL MOUNTED RETURN GRILLE• INSTALL GRILLE AT A MINIMUM OF 6" A.F.F.• ROUTE RETURN DUCT FROM GRILLE TO BOTTOM RETURN OF UNIT.

AEED,Advanced Energy Engineering & Design, Inc

CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369

P.O. BOX 4934408 McCALLIE AVE

inc.

AEED JOB NO. 029-15

COPYRIGHT NOTICE

THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.

714

cher

ry s

treet

, cha

ttano

oga,

tenn

esse

e 37

402

p.42

3 63

4 08

06 f

.423

752

849

9 w

ww

.rive

r-st

-arc

hite

ctur

e.co

m

Release Date:Project No.:

3/31

/201

5 10

:17:

24 A

M

1205

5 G

ATE

WA

Y W

ES

T B

LVD

, EL

PA

SO

, TX

CO

UR

TY

AR

D B

Y M

AR

RIO

TT

ZAR

AG

OZA

HO

TEL

PA

RTN

ER

S, L

LC

MECHANICAL

M2.1

SCHEDULES

OPTIONS-ACCESSORIES-NOTES

2. PROVIDE SINGLE POINT CONNECTION.

5. VERIFY PROPER VOLTAGE WITH ELECTRICAL CONTRACTOR BEFORE ORDERING EQUIPMENT.

3. ACCEPTABLE MANUFACTURERS: CARRIER, TRANE, YORK, LENNOX

4. VERIFY PROPER VOLTAGE WITH ELECTRICAL CONTRACTOR BEFORE ORDERING EQUIPMENT.

HEAT PUMPHEATING CAPACITY

(MBH)

1. PROVIDE COMPLETE WITH PROGRAMMABLE T'STATNOTES:

3. ACCEPTABLE MANUFACTURERS: CARRIER, TRANE, YORK, LENNOX

1. PROVIDE COMPLETE WITH COIL GUARDS

MARK

AHU-1

NOTES:

CFMSUPPLY

COOLING

(MBH)

CAPACITY

MOCPVOLT.-PH.-CY.

BACKUP ELECTR.RESIST. HEATING

KW

ELECTRICAL

MCAMANUFACTURER & MODEL

OPTIONS-ACCESSORIES-NOTES

ELECTRICAL

VOLT.-PH.-CY.INDOOR UNIT

HP-1

REFRIG. PIPING

SUCTION LIQUIDMANUFACTURER & MODEL

SPLIT SYSTEM HEAT PUMP - OUTDOOR UNIT SCHEDULE

SPLIT SYSTEM HEAT PUMP - INDOOR UNIT SCHEDULE

AHU-2

TOTAL

COOLING

(MBH)

CAPACITYSENSIBLE

EER

HP-2

COOLINGCAPACITY

(MBH)

HEATINGCAPACITY

(MBH)

AHU-3

HP-3

AHU-4

HP-4

7. PROVIDE UNIT WITH DUCT MOUNTED SMOKE DETECTORS IN SUPPLY AND RETURN DUCTS OF UNIT. DETECTORS TO BE PROVIDED AND WIRED BY ELECTRICAL CONTRACTOR AND INSTALLED IN DUCT BY MECHANICAL CONTRACTOR.

6. PROVIDE UNIT WITH AUXILIARY CONDENSATE DRAIN PAN UTILIZING SHUT DOWN FLOAT SWITCH. PROVIDE COMPLETE WITH CONDENSATE DRAIN PUMP CAPABLE OF ACHIEVING PROPER FLOW AS INDICATED BY DRAWINGS.

5. DURING AUXILIARY HEATING MODE OUTDOOR UNIT SHALL DE-ENERGIZE TO PREVENT SIMULTANEOUS OPERATION OF ACCESSORY HEAT AND HEAT PUMP.

9. WRAP UNITS WITH FOIL FACED FIBERGLASS OR CLOSED CELL ELASTOMERIC INSULATION. WRAP IN A MANNER TO ALLOW OPERATION/ACESS OF ALL FILTERS, CONTROL PANELS, ACCESS DOOR, S ETC.

8. DURING AUXILIARY HEATING MODE OUTDOOR UNIT SHALL DE-ENERGIZE TO PREVENT SIMULTANEOUS OPERATION OF ACCESSORY HEAT AND HEAT PUMP.

4. PROVIDE WITH FILTER RACK AND 1" THICK PLEATED-MEDIA DISPOSABLE FILTERS, EQUAL TO FARR 30/30.

HP-5

AHU-5

OUTDOORUNIT

MIN. O.A.AIR CFM

EXT. S.P.(IN. W.G.)

MCA MOCPMARK

KEF-1

NOTES:

DISCHARGE

VENTILATING FAN SCHEDULE

MODEL/CAT#DESIG. MFGR. TYPE H 2OCFMS.P.

h.p. / wattsMIN.

LEVELRPMFAN SONE

OPTIONS-ACCESSORIES-NOTES

1. PROVIDE COMPLETE WITH ROOF CURB, CURB TO OFFSET ANY ROOF SLOPE.2. PROVIDE COMPLETE WITH BUG SCREEN.3. INTERLOCK KEF-1 & KSF-1 WITH COOKING HOOD TO RUN SIMULTANEOUSLY.4. INTERLOCK DEF-1 WITH DISH HOOD TO RUN SIMULTANEOUSLY.5. FAN TO RUN CONTINUOUSLY.6. INTERLOCK FAN WITH LIGHTSWITCH.

2. REFRIGERANT PIPING TO BE SIZED BY EQUIPMENT MANUFACTURER OR FACTORY- AUTHORIZED REPRESENTATIVE. SIZING CALCULATIONS TO BE BASED ON ACTUAL FIELD ROUTING AND CONFIGURATION.

ELECTRIC HEATER SCHEDULE

MFR.

EWH-1

MARK MODEL # VOLTS/PH.KW MOUNTING REMARKS

NOTES:

OPTIONS-ACCESSORIES-NOTES

EWH-2

EWH-3

EWH-4

1. PROVIDE WITH WALL RECESSED MOUNTING KIT.2. PROVIDE WITH HANGING KIT COMPLETE WITH VIBRATION ISOLATION ACCESSORIES.

VOLTS/ PH

MOCPTOTAL CAPACITY SENSIBLETOTAL CAPACITY wbdb VOLT.-PH.-CY.MCA

ELECTRIC

MAU-1

SERVICEMANUFACTURER & MODELSYSTEM MBHCOIL EAT

COOLING CAPACITIES

NO.EQUIPMENT

GAS FIRED ROOF MOUNTED MAKE UP AIR UNIT WITH DX COOLING

FAN(HP)

MAU-2

OPTIONS-ACCESSORIES-NOTESFAN(HP) (MBH)

INPUTEXT. S.P.(IN. W.G.)

SUPPLYAIR (CFM)

EXHAUSTAIR (CFM)

EXT. S.P.(IN. W.G.)

SUPPLY FAN SECTION EXHAUST FAN SECTION GAS HEATUNIT

WEIGHT(LBS)

wbdb

COIL LAT

dbLAT

HOT GAS RE-HEAT

TC(MBH)

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

FIELD MOUNTED CONTROLS SHALL INCLUDE A DUCT MOUNTED LEAVING AIR STAT AND A WALL MOUNTED STAT (SEE PLANS FOR LOCATION)ALL UNIT MOUNTED CONTROLS FOR COMPLETE OPERATION SHALL BE INSTALLED BY THE EQUIPMENT MANUFACTURER

13. UNIT SHALL INCLUDE INTEGRAL NON-FUSED DISCONNECT14. DUCT MOUNTED SMOKE DETECTORS PROVIDED BY ELECTRICAL, INSTALLED BY MECHANICAL15. UNIT SHALL INCLUDE A 30" HIGH FACTORY ASSEMBLED AND INSULATED ROOF CURB/PLENUM WITH VIBRATION ISOLATION RAILS16. UNIT SHALL BE AHRI LISTED AND CERTIFIED (COIL ONLY CERTIFICATION NOT ACCEPTABLE)17. COMPRESSORS SHALL HAVE 5 YEAR WARRANTY (PARTS ONLY)18. PROVIDE UNIT WITH DUCT MOUNTED SMOKE DETECTORS IN SUPPLY AND RETURN DUCTS OF UNIT. DETECTORS TO BE PROVIDED AND WIRED BY ELECTRICAL CONTRACTOR AND INSTALLED IN DUCT BY MECHANICAL CONTRACTOR.

MAXTEMP

RISE °F

19. PROVIDE HURRICANE CLIPS FOR ALL MAU ROOFTOP UNITS AND CURBS. SEE DETAIL ON M203.

HP-6

HP-7

AHU-6

AHU-7

AHU-1 ALL

AHU-6 ALL

HP-1

HP-6

AHU-2 ALL

AHU-4 ALL

HP-2

HP-4

AHU-5 ALL

AHU-7 ALL

HP-5

HP-7

AHU-3 ALL

HP-3

HP-8

AHU-8

AHU-8 ALL

HP-8

(MBH)OUTPUT

GUEST ROOM - OUTSIDE AIR / EXHAUST

GUEST ROOM - OUTSIDE AIR / EXHAUST

GREENHECK

MARKEL

MARKEL

MARKEL 3420 F3423 3 208/1 WALL SURFACE MOUNTED W/ INTERGRAL T'STAT 1

MARKEL

EUH-1 REZNOR EGEB-5 5 208/1 SUSPENDED SUSPENDED FROM STRUCTURE W/ INTERGRAL T'STAT 2

3420 F3423 3 208/1 WALL SURFACE MOUNTED W/ INTERGRAL T'STAT 1

3420 F3423 3 208/1 WALL SURFACE MOUNTED W/ INTERGRAL T'STAT

3420 F3423 3 208/1 WALL SURFACE MOUNTED W/ INTERGRAL T'STAT

1

1

EWH-5 MARKEL 3420 F3423 3 208/1 WALL SURFACE MOUNTED W/ INTERGRAL T'STAT 1

CARRIER / FX4DNF061 2000 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0375

CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2 208/3 21.1 30

CARRIER / FX4DNF061 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0400

CARRIER / FX4DNF061 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0425

CARRIER / FX4DNF061 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0265

CARRIER / FX4DNF061 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0300

CARRIER / FX4DNF061 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0300

CARRIER / FX4DNF061 0.5 59.45 43.1 57.74 11.3 208-1-60 76.3 80.0300

CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2

CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2

CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2

CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2

CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2

CARRIER / 25HCD360 57.74 59.45 11.5 NOTE 2 NOTE 2

2000

2000

2000

2000

2000

2000

ELECTRIC DUCT HEATER SCHEDULE

ITEM MANUFACTURER MODEL NO. CFM KW STEPS VOLTS/ᴓ DIMENSIONS TEMP RISE (°F) NOTES

EDH-1 MARKEL HF 2456 23 2 208/3 30"W x 12"H 30 1

NOTES:1. INSERT TYPE WITH BUILT-IN FAN INTERLOCK, OVERTEMPERATURE CONTROL, CONTROL CONTACTOR, AND DUCT MOUNTED T-STAT.2. HEATER TO ENERGIZE AT 40°F AIR STREAM DETECTION.

208/3

208/3

208/3

208/3

208/3

208/3

KSF-1 GREENHECK

DEF-1 GREENHECK

CUBE-200 ROOF VERTICAL 3070 1.0 1.0 208/1 961 14.8

SAF-112 ROOF VERTICAL 2456 0.75 3/4 208/1 875 19.5

CUBE-101 ROOF VERTICAL 525 0.5 1/4 208/1 1162 5.8

1,2,3

1,2,3

1,2,4

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

CARRIER / FX4DNF025 800 0.5 23.0 17.38 22.3 3.8 208-1-60 26.0 30.0150

CARRIER / 25HCD424 22.3 23.0 12.0 NOTE 2 NOTE 2 208/1 17.7 25

21.1 30

21.1 30

21.1 30

21.1 30

21.1 30

21.1 30

STEEL

ALUM

ALUM

OPPOSED BLADE DAMPER

N/A

350RS

TMS

50F

24x24 LAY-IN/SURFACE MOUNTED SUPPLY DIFFUSER, ROUND NECK

EGGCRATE STYLE RETURN / TRANSFER GRILLE

SURFACE MOUNTED RETURN GRILLE N/A

FINISHAIR CONTROL MATERIAL

AIR DISTRIBUTION SCHEDULE

MODEL/CAT#DESCRIPTION

TITUS

TITUS

MFGR.

NOTES:

DESIG. OPTIONS-ACCESSORIES-NOTES

TITUS

1. ACCEPTABLE MANUFACTURERS: METALAIRE, ANEMOSTAT, OR BY ENGINEER2. PROVIDE COMPLETE WITH ALL CLIPS, MARGINS AND HARDWARE FOR INSTALLATION TYPE. CONTRACTOR/MFG REP SHALL EXAMINE DRAWINGS TO DETERMINE INSTALLATION TYPE.3. COORDINATE COLOR WITH ARCHITECT.4. SEE DRAWING FOR CONNECTION SIZE.

ALUMTBD-10 N/A 1,2,4TITUS HIGH ADJUSTABLE CAPACITY LINEAR SLOT WITH 10" or 8" INLET (2 x 1.5" SLOT WIDTH 4'-0" LONG)

3

3

3

3

A

B

D

C

E

1,2,4

1,2,4

1,2,4

F

TITUS

TITUS ALUM250-AASURFACE MOUNTED SUPPLY GRILLE (4 WAY THROW) N/A 3 1,2,4

ALUM350RSSURFACE MOUNTED RETURN GRILLE N/A 3 1,2,4

CARRIER / 62DCF020-S4B31FTD34020 3550 2.0 3.02.0 5 300 201.6 74.6 112.6 25.7 101 70 50.9 50.9 192.14 188.56 2500208/3100 125

CARRIER / 62DCJ024-V4B31G8D35805 4260 2.0 5.02.0 10 600 403.2 95.2 139.2 22.1 101 70 57.1 56.8 238.64 238.55 4000208/3120 150

ALL

ALL

GREENHECK SP-A70 CEILING 50 0.20 850115/120 watts 1.3 6HORIZONTALEF-2

GREENHECK SP-A70 CEILING 50 0.20 850115/120 watts 1.3 5HORIZONTALEF-1

AEED,Advanced Energy Engineering & Design, Inc

CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369

P.O. BOX 4934408 McCALLIE AVE

inc.

AEED JOB NO. 029-15

COPYRIGHT NOTICE

THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.

714

cher

ry s

treet

, cha

ttano

oga,

tenn

esse

e 37

402

p.42

3 63

4 08

06 f

.423

752

849

9 w

ww

.rive

r-st

-arc

hite

ctur

e.co

m

Release Date:Project No.:

3/31

/201

5 10

:17:

24 A

M

1205

5 G

ATE

WA

Y W

ES

T B

LVD

, EL

PA

SO

, TX

CO

UR

TY

AR

D B

Y M

AR

RIO

TT

ZAR

AG

OZA

HO

TEL

PA

RTN

ER

S, L

LC

MECHANICAL

M2.2

SCHEDULES

VOLTSOA CFMCFMOUTDOORMANUFACTURERMARK

DUCTLESS A/C SCHEDULE - COOLING ONLY

INDOOR COOLING (MBH)INDOOR

1. SANYO OR MITSUBISHI ARE ACCEPTABLE ALTERNATIVES.2. VERIFY PROPER VOLTAGE WITH ELECTRICAL CONTRACTOR.3. PROVIDE WITH MOUNTING KIT COMPATIBLE WITH WALL MOUNTING APPLICATION.

HWFC-1/HW-CU-1

OPTIONS-ACCESSORIES

NOTES:

5. PROVIDE ACCESSORY LONG RUN REFRIGERANT LINE KIT.

VOLTSOUTDOOR

(MCA/MOCP) (MCA/MOCP)

6. MAIN POWER SUPPLIED TO OUTDOOR UNIT. FIELD SUPPLIED CONNECTION CABLE FROM OUTDOOR TO INDOOR SUPPLIES POWER TO INDOOR UNIT.

7. PROVIDE CONDENSATE PUMP INSTALLED INSIDE UNIT (REMOTE MOUNT UNACCEPTABLE)8. PROVIDE WITH LOW AMBIENT OPERATION KIT, WIND BAFFLE & CRANKCASE HEATER.

4. ROUTE CONDENSATE DRAIN LINES AS SHOWN ON PLUMBING PLANS.

HI - MED - LOW

9. COORDINATE OUTDOOR UNIT MOUNTING TYPE WITH PLANS. (HOUSE KEEPING PAD OR METAL WALL BRACKET)

HWFC-2/HW-CU-2

038MVC018 18.011/20 1 32 4 5208/1/60 76CARRIER 840MVC018 630 - 570 - 500 9

PACKAGE THROUGH-THE-WALL A/C UNIT

HEATING (BTUH)MARK MANUFACTURER MODEL NO. TH

COOLING (BTUH)ENTERINGAIR

db wbEER VOLT/PH

ELECTRCAL DATA

NOTES:

CFM

TOT OA

2. CONDENSATE IS TO BE ROUTED TO CONDENSATE DRAINS SHOWN ON PLUMBING DRAWINGS.

MCA MOCP

PTAC-1 208/111.36780 9.0 8.1310 - 16.5 20GREE ETAC09HP208V20

OPTIONS-ACCESSORIES

ALL

3. PROVIDE COMPLETE WITH FACTORY SUB-BASE, HARDWIRE KIT AND POWER DISCONNECT SWITCH. ACCOUNT FOR SUB-BASE HEIGHT WHEN DETERMINING A.F.F. INSTALLATION HEIGHT.

ELECTRICHEATER

(KW)

3.0

WEIGHT(LBS)

145

47°

4. PTAC RISER BY PLUMBING CONTRACTOR, CONNECTION FROM PTACS TO RISER BY MECHANICAL.5. ACCEPTABLE ALTERNATES ARE AMANA & GE. (VERIFY 277 VOLTAGE AVAILABILITY PRIOR TO SUBMITTING)

1. PROVIDE WITH WALL SLEEVE, STANDARD GRILLE, UNIVERSAL DRAIN KIT REMOTE MOUNTED MANUAL T-STAT WITH TWO SPEED FAN CONTROL CAPABILITY.

6. PROVIDE WITH REMOTE MOUNTED MANUAL T-STAT WITH TWO SPEED FAN CONTROL CAPABILITY.

HWFC-3/HW-CU-3

HWFC-4/HW-CU-4

HWFC-5/HW-CU-5

HWFC-6/HW-CU-6

1 32 4 5 7CARRIER 8 9

038MVC018 18.011/20 1 32 4 5208/1/60 76CARRIER 840MVC018 630 - 570 - 500 9

1 32 4 5 7CARRIER 8 9

038MVC018 18.011/20 1 32 4 5208/1/60 76CARRIER 840MVC018 630 - 570 - 500 9

1 32 4 5 7CARRIER 8 9

038MVC018 18.011/20208/1/60640MVC018 630 - 570 - 500

038MVC018 18.011/20208/1/60640MVC018 630 - 570 - 500

038MVC018 18.011/20208/1/60640MVC018 630 - 570 - 500

038MVC018 18.011/20208/1/60640MVC018 630 - 570 - 500

6

6

6

6

6

6

6

AEED,Advanced Energy Engineering & Design, Inc

CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369

P.O. BOX 4934408 McCALLIE AVE

inc.

AEED JOB NO. 029-15

COPYRIGHT NOTICE

THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.

714

cher

ry s

treet

, cha

ttano

oga,

tenn

esse

e 37

402

p.42

3 63

4 08

06 f

.423

752

849

9 w

ww

.rive

r-st

-arc

hite

ctur

e.co

m

Release Date:Project No.:

3/31

/201

5 10

:17:

24 A

M

1205

5 G

ATE

WA

Y W

ES

T B

LVD

, EL

PA

SO

, TX

CO

UR

TY

AR

D B

Y M

AR

RIO

TT

ZAR

AG

OZA

HO

TEL

PA

RTN

ER

S, L

LC

MECHANICAL

M3.1

DETAILS

TYPICAL BOTTOM OF DUCT DIFFUSER CONNECTIONSCALE: NONE

SUPPLY DUCT MAIN

FLEX DUCT WHEREREQUIRED (MAX.

LENGTH 6'-0")

FLEX DUCT SIZES SHALLMATCH NECK SIZES

OPPOSED BLADEDAMPER

DRAW BAND WITHSILICONE SEALER

HAND DAMPER

CEILINGDIFFUSER

COLLAR

CEILING

DRAIN PAN

CONDENSATE DRAIN DETAILSCALE: NONE

EACH DIMENSION ISEQUAL TO FAN NEGATIVE

STATIC PRESSURE

UNIONREMOVABLE CAP

FULL SIZE OFDRAINCONNECTION

APPROVED AIRGAP HEIGHT

LOCAL ROOF DRAIN,FLOOR DRAIN, OR

FLOOR SINK.

LEVELING LEG

FOUNDATION WALL

OUTSIDE WALL

EXTERIOR LOUVER ANDDAMPER

LOCKED CONTROL PANEL

WALL SLEEVE

PTAC UNIT

PACKAGED THROUGH THE WALL TERMINAL AC UNITSCALE: NONE

ELECTRIC WALL HEATER MOUNTING DETAILSCALE: NONE

6" THICK CONC. PAD - EXTEND6" BEYOND UNIT ALL AROUND

SIGHT GLASS WITHMOISTURE INDICATOR

FILTER-DRYERCONDUIT - POWERAND CONTROL

REFRIGERANT LIQUID LINE

REFRIGERANT SUCTIONLINE WITH INSULATION

CONDENSING UNIT

FAN GUARD

CONDENSING UNIT - SLAB MOUNTED AT GRADESCALE: NONE

BACK-SEATED REFRIGERANTVALVE

DUCT HANGER DETAILSSCALE: NONE

SHEET METAL SCREW

SECURE TO STRUCTUREABOVE AS RECOMMENDEDBY SMACNA

HANGER RODTYPE "B" 5/16" DIA.TYPE "C" 3/8" DIA.TYPE "D" 1/2" DIA.

FOR BRACING ANGLESSEE NOTES

NUT & WASHER ATEND OF ROD

TYPE "A"

TYPE "B", "C", "D"

MAX SIDE MAX SIDERIVET OR BOLT TOBOTH SIDES OF DUCT& A MIN. OF 1" BENEATH DUCT FORBOTH STRAPS

1" X 16 GAGALV. IRONSTRAP ORALUMINUM

(8 FT. MAX HANGER SPACING. ALSOPROVIDE 3 HANGERS AT EACH TAKE-OFFOR BRANCH.)

(8 FT. MAX HANGER SPACING )

NOTES:

1.) FOR SEVERAL DUCTS ON ONE HANGER, TYPE "B", "C",OR "D" MAY BE USED. SIZE OF HANGER WILL BE SELECTED ON SUM OF DUCT WIDTHS EQUAL TO MAXIMUMWIDTH OF DUCT SCHEDULE.

2.) SCHEDULE FOR ANGLES FOR BRACING: TYPE "B" -1-1/2 X 1-1/2 X 1/8 ANGLE, MAX. SPACING 8'-0"CENTERS; TYPE "C" - 1-1/2 X 1-1/2 X 3/16 ANGLE,MAX. SPACING 8'-0" CENTERS; TYPE "D" - 2 X 2 X 1/4ANGLE, MAX SPACING 4'-0" CENTERS.

DUCT SCHEDULE

DUCTDIMENSIONS(INCHES)

TYPEHANGER

AA

A/B

B

B

BCC

DOVER 96

85 " 9661 " 8455 " 60

43 " 54

31 " 42

19 " 30

13 " 18UP THRU 12

OPENING HEIGHT

TOP BLADE RIVETED

TO FRAME

SLEEVE

COLLARSTEEL BLADES WITHINTERLOCKING JOINTS

BLADE AND LINK

CINCH

FUSIBLE LINK

STEEL FRAME

ASSEMBLED

INTO WELDED

HOUSING

1" TYPICAL

3 SIDES

3/4" TYP.

3 SIDES

DUCT HEIGHT LESS

1/4" 100% FREE-

AREA

(DAMPER HEIGHT

IS 1/4" LESS)

3"

5"

FIRE DAMPER DETAILSCALE: NONE

DUCT SUPPORTS OFF ROOF DETAILSCALE: NONE

INSULATION

METAL DECK

SUPPORT

PROVIDE PITCH WITH INSULATIONMATERIAL FOR DRAINAGE

STRUCTURAL SHAPEAS PER SMACNA(ANGLE IRON OR PIPE)

SUPPORT LEGSWELD TO ANGLE (TYPICAL)

ANGLE IRON FASTENEDTO EQUIPMENT SUPPORT

COUNTER FLASHING HOOD

MEMBRANE ROOF

PREFABRICATEDEQUIPMENT

INVERTED ANGLE IRON

ANCHOR EQUIPMENT SUPPORTTO METAL DECK

DUCTWORK SUPPORTED AS PER SMACNA

SEAL ALL ANGLES WEATHER TIGHT

ANGLE IRON WELD TO PIPEOR ANGLE IRON (TYPICAL)

AT ROOF DUCT SUPPORT-INSULATEOVER ANGLE IRON SUPPORTS ANDSEAL ALL CORNERS OF ANGLES IN AWEATHER TIGHT MANNER

MIN

IMU

M

2'-0

"

INSULATED DOUBLE WALL SUPPLY ORRETURN DUCTWORK WITH WATER TIGHTSEAMS AND WEATHER RESISTANT FINISH.

INLINE EXHAUST FANS (TYP)

MOTOR

BELT GUARD

FLOWAIR

FLEXIBLE CONNECTION

DUCTWORK

STEEL SPRING AND RUBBERIN SHEAR TYPE VIBRATIONISOLATORS

MOUNTING BRACKET

ADJUSTABLE SHEAVEDRIVE PULLEY

FLOW

DUCTWORK

AIR

FLEXIBLE CONNECTION

ADJUSTABLE MOTOR MOUNT

3/8"O ALL THREADED STEEL RODSSUPPORT FROM BUILDING STRUCTURE LENGTH OF RODS TO SUIT SPACEAVAILABLE

FIRE DAMPER AT SUPPLY REGISTER/GRILLE DETAILSCALE: NONE

(COOLING SUPPLY ONLY)DUCT TO PREVENT SWEATINGEXTERNAL INSULATION ON

RETURN OR FUSIBLE LINK

FIRE DAMPER

RETURN AIR GRILLE ORSUPPLY REGISTER

FIRE RATED WALL

SUPPLY DUCT

ABOVE CEILING IN-LINE MOUNTED EXHAUST FAN DETAILSCALE: NONE

FACTORY SUB- BASE KIT

6" ABOVE FINISHED FLOOR (MINIMUM)

UNIT RECESSED IN WALLPER MFG GUIDELINES

ELECTRIC HEATER,RECESSED WALL MOUNTED

SEE DETAIL A

1/2"

1" MIN.1 1/2"

CEILING RADIATION DAMPER DETAILSCALE: NONE

CURB AND EQUIPMENT HURRICANE CLIP DETAILSCALE: NONE

BELOW GRADE

ABOVE GRADE

AEED,Advanced Energy Engineering & Design, Inc

CHATTANOOGA, TN 37405BUS. (423) 752-3438FAX (423) 752-1369

P.O. BOX 4934408 McCALLIE AVE

inc.

AEED JOB NO. 029-15

COPYRIGHT NOTICE

THE DRAWINGS ARE THEPROPERTY OF RIVER STREETARCHITECTURE LLC. ANY USE,REUSE, REPRODUCTION,DISPLAY OR SALE OF THESEDRAWINGS WITHOUT THEEXPRESS WRITTEN CONSENTOF THE ARCHITECT ISSTRICTLY PROHIBITED.

714

cher

ry s

treet

, cha

ttano

oga,

tenn

esse

e 37

402

p.42

3 63

4 08

06 f

.423

752

849

9 w

ww

.rive

r-st

-arc

hite

ctur

e.co

m

Release Date:Project No.:

3/31

/201

5 10

:17:

24 A

M

1205

5 G

ATE

WA

Y W

ES

T B

LVD

, EL

PA

SO

, TX

CO

UR

TY

AR

D B

Y M

AR

RIO

TT

ZAR

AG

OZA

HO

TEL

PA

RTN

ER

S, L

LC

MECHANICAL

M3.2

DETAILS

NOTES:

1 SPIN IN CONICAL BRANCH TAP FITTING WITH MANUAL VOLUME DAMPER. BRANCHRUNOUT DUCT SHALL BE THE SAME DIAMETER AS THE AIR TERMINAL INLET.

2 DUCT STRAP HANGER. ATTACH TO STRUCTURE.

3 STRAP HANGER REQUIRED IF BRANCH RUNOUT LENGTH IS GREATER THAN 4 FT.

4 MAXIMUM FLEXIBLE DUCT LENGTH IS 5 FT. FLEXIBLE DUCT SHALL BE THE SAMEDIAMETER AS THE AIR TERMINAL INLET. FLEXIBLE DUCT SHALL BE INSULATED.STRETCH FLEXIBLE DUCT TO A MINIMUM OF 90% OF ITS FULLY EXTENDED LENGTH.SEAL CONNECTIONS AIR TIGHT.

5 HARD ELBOW TO AIR TERMINAL CONNECTION.

6 COMPRESSION FITTING AT AIR TERMINAL CONNECTION.

7 PROVIDE ALL CLIPS AND MARGINS REQUIRED FOR A COMPLETE INSTALLATION.COORDINATE LOCATION AND FINISH WITH OWNER/ARCHITECT.

12 3

4

5

67

NOTES:

1 SPIN IN CONICAL BRANCH TAP FITTING WITH MANUAL VOLUME DAMPER. BRANCHRUNOUT DUCT SHALL BE THE SAME DIAMETER AS THE AIR TERMINAL INLET.

2 DUCT STRAP HANGER. ATTACH TO STRUCTURE.

3 STRAP HANGER REQUIRED IF BRANCH RUNOUT LENGTH IS GREATER THAN 4 FT.

4 MAXIMUM FLEXIBLE DUCT LENGTH IS 5 FT. FLEXIBLE DUCT SHALL BE THE SAMEDIAMETER AS THE AIR TERMINAL INLET. STRETCH FLEXIBLE DUCT TO A MINIMUM OF90% OF ITS FULLY EXTENDED LENGTH. SEAL CONNECTIONS AIR TIGHT.

5 HARD ELBOW TO AIR TERMINAL CONNECTION.

6 SHEET METAL PLENUM. PLENUM SHALL BE SAME SIZE AS GRILLE CONNECTION.

7 PROVIDE ALL CLIPS AND MARGINS REQUIRED FOR A COMPLETE INSTALLATION.COORDINATE LOCATION AND FINISH WITH OWNER/ARCHITECT.

12 3

4

5

6

7

NOTES:

1 SPIN IN CONICAL BRANCH TAP FITTING WITH MANUAL VOLUME DAMPER. BRANCHRUNOUT DUCT SHALL BE THE SAME DIAMETER AS THE AIR TERMINAL INLET.

2 DUCT STRAP HANGER. ATTACH TO STRUCTURE.

3 STRAP HANGER REQUIRED IF RUN OUT LENGTH IS GREATER THAN 4 FT.

4 MAXIMUM FLEXIBLE DUCT LENGTH IS 5 FT. FLEXIBLE DUCT SHALL BE THE SAMEDIAMETER AS THE AIR TERMINAL INLET. STRETCH FLEXIBLE DUCT TO A MINIMUM OF90% OF ITS FULLY EXTENDED LENGTH. SEAL CONNECTIONS AIR TIGHT.

5 SPIN IN CONICAL BRANCH TAP FITTING. BRANCH RUNOUT DUCT SHALL BE THE SAMEDIAMETER AS THE AIR TERMINAL INLET.

6 SHEET METAL PLENUM. PLENUM SHALL BE SAME SIZE AS GRILLE CONNECTION.

7 PROVIDE ALL CLIPS AND MARGINS REQUIRED FOR A COMPLETE INSTALLATION.COORDINATE LOCATION AND FINISH WITH OWNER/ARCHITECT.

12 3

5 6

7

TYPICAL SUPPLY AIR TERMINAL CONNECTION

TYPICAL AIR TERMINAL CONNECTIONLIMITED CLEARANCE APPLICATION

SCALE: NONE

SCALE: NONE

TYPICAL RETURN & EXHAUST AIR TERMINAL CONNECTIONSCALE: NONE

CEILING EXHAUST FAN DETAILSCALE: NONE

FLEXIBLE CONNECTION

SUPPORT FAN FROMSTRUCTURE ABOVE WITHTHREADED RODS &VIBRATION ISOLATORS

PROVIDE INTEGRAL GRILLEUNLESS OTHERWISE INDICATED

PROVIDE FAN COMPLETE WITH BACKDRAFT DAMPER AND WALL CAP

CURB MTD.EQUIPMENT

MATERIALROOFING

ROOF

DISTANCE EQUAL TOINSULATION THICKNESS

INSULATIONROOF

LOWEST POINT

DECK

FINISHED ROOF ATMINIMUM, 12" ABOVE

NOTE:1. COORDINATE FLASHING DETAIL WITH ROOFING SYSTEM PROVIDER

TYPICAL ROOF CURB DETAILSCALE: NONE

AS REQ'D

12"

AS R

EQ'D

45

1" MAX.

4"

16 GA. SHEETMETAL

DRILL & CAULKIN FIELD.

1"INSULATIONPROVIDE WASHER FOR WATERTIGHT CONNECTION.

PIPING THRU ROOF DETAILSCALE: NONE

NOTE:PIPES TO EXIT IN HORIZONTALARRANGEMENT ONLY. DO NOTSTACK PIPES OVER ONE ANOTHER.

THICKNESS FROM TOP OF ROOFTO TOP OF DECK.

COMBINATION FIRE/SMOKE DAMPERSCALE: NONE

CONTROLLED ROUND OR RECTANGULAR DAMPERS, AND CAN BE MOUNTED IN A WIDESYSTEM IS DESIGNED FOR USE WITH EXTERNALLY 1)

NOTES: LINEAR SLOT DIFFUSER

RIGID DUCTWORK

FLEXIBLE DUCTWORK

AND WIRE (50'-0"

RACK & PINION

FLEXIBLE CASING

MAXIMUM)

OPERATOR

MOUNTING BRACKET

VARIETY OF LOCATIONS INCLUDING CEILING JOISTS, LAY-IN CEILINGS, BEHIND GRILLES,SOCKET WRENCH

WITH PLENUM BOX

LOCKING

CABLE SHALL CONSIST OF 0.054" STAINLESS STEEL CONTROL WIRE ENCAPSULATED IN 1/16" FLEXIBLE GALVANIZED SPIRAL WIRE SHEATH.

LOCKING RACK AND PINION GEAR DRIVE SHALL BE CONSTRUCTED OF 14 GAUGE STEEL AND SHALL BE USED TO CONVERT ROTARY MOTION INTO PUSH-PULL MOTION.

CONTROL SHAFT SHALL BE "D"-STYLE FLATTENED 1/4" DIAMETER WITH 265° ROTATION PROVIDING 1-1/2" LINEAR TRAVEL CAPABILITY.

2)

3)

4)

ON OR INSIDE OTHER VARIOUS TYPES OF DIFFUSERS, ETC.

RECTANGULARROUND DAMPER OR

OPPOSED BLADE DAMPER

CABLE CONTROLLED DAMPER DETAILSCALE: NONE

ALL RELAYS, WIRING AND TRANSFORMERS REQUIRED TO INTERLOCKSMOKE DETECTOR WITH SMOKE DAMPER OPERATOR ARE THE

RESPONSIBILITY OF DIV. 15000