1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl....
-
Upload
german-stinchfield -
Category
Documents
-
view
227 -
download
2
Transcript of 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl....
![Page 1: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/1.jpg)
1
WELCOME TO
Presentation on New Concepts in Supercritical
Turbines
Sanjoy Bhattacharya
Dy. Genl. Manager, BHEL, Hardwar
![Page 2: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/2.jpg)
2
![Page 3: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/3.jpg)
3
HPT IPT LPT
CROSS SECTIONAL ARRANGEMENT OF 500 MW STEAM TURBINE
THREE CYLINDER TURBINE
![Page 4: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/4.jpg)
4
Introduction of New Rating SetsMajor Objectives
Bring down equipment cost per MW
Having more Efficient & Reliable product
Utilize available Steam turbine modules
Provide Higher competitiveness
New Rating to compete with Chinese/ New Indian firms
![Page 5: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/5.jpg)
5
600MW Steam turbine: Built from proven modules of existing 500 & 250 MW
Orders for 4x600 MW Raigarh-III (Jindal), 2x600 MW Malwa, 2x600 MW each Avantha / Videocon/ Visa Raigarh/ DB Power & 1 x 600 MW Rayalaseema received .
Module Combination• HP: H30-100• IP : M30-63• LP : N30-4x6.3
Salient features:• 4 cylinder turbine (2 LPs)• HP turbine with Extraction connection for 565 HRH Temp• IP turbine suitable for 537/565 0C inlet temp.
OPTIONS1. HP Turbine with Extraction & 565 Deg C HRH Temp 2. HP Turbine without Extraction & 537 Deg C HRH Temp
Orders for 2 sets - N Chennai, 2 sets –JITPL, 1 set -APGENCO & 2 sets Singareni received.
Steam parameters 170 ata / 537 0C/ (537-565) 0C
![Page 6: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/6.jpg)
6
600MW Steam Turbine
Design Changes from existing 500 MW sets :
•HP module variant with Extraction• New Flow path in HP, IP & LP Turbines (with Advanced blading)
• Matching modifications in Rotors & Inner Casings
• New Bearing pedestal between 2 LP cylinders
• New design of Cross Around Pipe & its support
• Enhanced governing characteristics
600 MW Sub critical Sets
Steam Turbine
![Page 7: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/7.jpg)
500/ 600 MW SUB CRITICAL CYCLE
WITH 2 HP HEATERS, 3 LP HEATERS
![Page 8: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/8.jpg)
8
Introduction of Steam Turbine with supercritical parameters
As the fluid pressure increases, Latent Heat (Enthalpy of Steam –Enthalpy of Water) reduces.
At Critical point it becomes zero.
In physical terms at this pressure water transforms to steam spontaneously.
SUPER CRITICAL STEAM PARAMETERS:
PARAMETERS MORE THAN CRITICAL STATE• STEAM PRESSURE > 221.2 BAR• STEAM TEMPERATURE > 374.15 Deg C
ULTRA SUPERCRITICAL PRESSURE( 300 BAR)
INCREASE IN PRESSURE & MAIN AND REHEAT TEMP. > 537 Deg CRESULTS IN SIGNIFICANT IMPROVEMENT IN HEATRATE
0
5
10
15
20
25
30
35
40
45
500 MW 800 MWSubcritical
170 ata / 537 °C / 537 °C
Super Critical247 ata / 565 °C /
593 °C
Imp
rov
em
en
t
4.3 %
![Page 9: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/9.jpg)
9
Steam Power plant efficiency increases with increase in steam pressure and temperature.
Power plant Cycles operating above critical pressure (221.2 bar) are classified as Supercritical cycles
With higher cycle efficiency, the supercritical cycle offers the advantage of ‘burn less fuel for the same output’ and lower emission.
Supercritical Cycles
Lesser Pollutants – SOX , NOX & CO2
![Page 10: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/10.jpg)
10
IMPROVEMENT IN EFFICIENCY WITH INCREASING INLET PARAMETERS FOR STEAM TURBINES
![Page 11: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/11.jpg)
11
PARAMETERS UNIT 500 MW 660 MW 800 MW
MS PRESSURE ATA 170 247 247
MS TEMPERATURE oC 537 565 565
MAIN STEAM FLOW T/HR 1500 1919 2380
REHEAT PRESSURE ATA 40.5 56 60
RH TEMPERATURE oC 537 593 593
FINAL FEED WATER TEMP.
oC 253 290 290
PARAMETERS FOR BHEL STEAM TURBINES
![Page 12: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/12.jpg)
12
Typical Supercritical TG Cycle
![Page 13: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/13.jpg)
13
REGENERATIVE CYCLE CONFIGURATION
• TWO EXTRACTIONS FROM IPT
• FOUR LP HEATERS
• DEAERATOR
• ONE EXTRATION FROM HPT
• THREE HP HEATERS
• 250% TURBINE DRIVEN BFP
• ONE MOTOR DRIVEN BFP
![Page 14: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/14.jpg)
14
STEAM TURBINE MODULE CONFIGURATION
MODULE 500 MW 660 MW 800 MW
HP TURBINE H30-100 H30-100 H30-100
IP TURBINE M30-63 M30-100 M30-100
LP TURBINE N30-2 x 10 N30-2 x 12.5 N30-4 x 8
HP VALVES 2 x FV320 2 xFV250A 2 xFV250A
IP VALVES 2xAV560 2xAV560A 2xAV560A
![Page 15: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/15.jpg)
15
![Page 16: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/16.jpg)
16
660MW Steam turbine: With Supercritical parameters
Order for 2x660 MW Barh- II/ DB Power & 3 x 660 Bara & Lalitpur TPPOther expected tenders 1 x 660 MW JITPL Angul, Jhabua Seoni, etc
Salient Feature:
• New series of HP & IP modules for supercritical parameters• Higher size LP module
247 ata Main Steam Pressure565 0C Main Steam Temperature593 0C Hot reheat Temperature
• Impulse tilted blade in HP & IP turbines
• Heat Shield at the inlet section
• Increase in wall/pipe thickness
• Material with improved properties for higher steam temperature
• Optimum flow path
![Page 17: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/17.jpg)
17
![Page 18: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/18.jpg)
18
800MW Steam turbine
Salient features:• 4 cylinder turbine (2 LP’s)• New series of HP, IP & LP modules for super critical parameters
HP Turbine
LP Turbine 1 LP Turbine 2
IP Turbine
Condenser
Generator
Orders for Yermarus (2x800 MW), & Edlapur (1x800 MW), JV between KPCL and BHELOrder expected for NTPC 2 x 800 MW Gajmara TPP & Udangudi (2x800 MW), JV between TNEB and BHEL
![Page 19: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/19.jpg)
19
800MW Steam turbine:
General Arrangement
![Page 20: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/20.jpg)
20
CROSS SECTIONAL ARRANGEMENT OF 800 MW STEAM TURBINE
FOUR CYLINDER TURBINE
![Page 21: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/21.jpg)
21
CONSTRUCTIONAL FEATURES OF HP TURBINE FOR 800 MW
• SINGLE FLOW, DOUBLE SHELL• OUTER CASING BARREL TYPE IN TWO PIECES• INNER CASING AXIALLY SPLIT• MONO BLOCK DRUM TYPE ROTOR
Barrel in two pieces
![Page 22: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/22.jpg)
22
CONSTRUCTIONAL FEATURES OF IP TURBINE FOR 800 MW
• DOUBLE FLOW, DOUBLE SHELL CASING• MONO BLOCK DRUM TYPE ROTOR • STEAM ADMISSION IN L/H FROM BOTH SIDES• EXTRACTIONS CONNECTIONS IN LOWER HALF ONLY• VALVES BOLTED TO THE CASING IN LOWER HALF
![Page 23: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/23.jpg)
23
HPT FIRST STAGE
Diagonal Impulse Blading
![Page 24: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/24.jpg)
24
IP Turbine : HEAT SHIELD WITH VORTEX BORES
![Page 25: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/25.jpg)
25
• DOUBLE FLOW, DOUBLE SHELL• OUTER CASING FABRICATED , INNER CASING CASTINGS• MONO BLOCK ROTOR
CONSTRUCTIONAL FEATURES OF LP TURBINE FOR 800 MW
![Page 26: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/26.jpg)
26
SECTIONAL DETAILS OF LP TURBINE FOR 660 / 800 MW
![Page 27: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/27.jpg)
27
INNER CASING IS INDEPENDENT OF OUTER CASING
INNER CASING RESTS ON OUTER CASING
660 MW500 MW
LP TURBINELP TURBINEDIFFERENCES IN CONSTRUCTIONAL FEATURES DIFFERENCES IN CONSTRUCTIONAL FEATURES
500 MW V/S 660 MW500 MW V/S 660 MW
![Page 28: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/28.jpg)
28
SECTIONAL DETAILS OF LP TURBINE FOR 660 / 800 MW
![Page 29: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/29.jpg)
29
PUSH ROD ARRANGEMENT
![Page 30: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/30.jpg)
30
LP TURBINE INNER CASING SUPPORT DETAILS FOR 660 / 800 MW
![Page 31: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/31.jpg)
31
THROTTLE CONTROLLED GOVERNING WITH
HIGH PRESSURE ELECTRO HYDRAULIC COMPACT ACTUATORS (160 BAR)
GOVERNING
![Page 32: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/32.jpg)
32
NEW DESIGN(660 MW)
THROTTLE GOVERNINGHIGH PRESSURE ELECTRO HYDRAULIC GOVERNING(ACTUATORS WITH PRESSURE OF 160 BAR)
Turbine Governing
EXISTING DESIGN(500 MW) THROTTLE GOVERNINGELECTRO HYDRAULIC(WITH 32 BAR PRESSURE)
![Page 33: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/33.jpg)
33
Turbine Governing ADVANTAGES OF EHA BASED SYSTEM
• Simplified plant layout due to overall compact size
• Control oil piping reduced• Faster response due to state of art
electronic control and protection system • Better interconnection with other system• Ease of operation and maintenance
• Valve room is avoided
![Page 34: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/34.jpg)
34
Turbine GoverningEHA SYSTEM CONSISTS OF
* HYDRAULIC POWER SUPPLY UNIT* HPSU CONTROL UNIT* VALVES ACTUATORS* CONTROLLERS* PROTECTION SYSTEMS
![Page 35: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/35.jpg)
35
OVERHAULING
![Page 36: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/36.jpg)
36
SUMMARY
• Proven Supercritical technology in collaboration with M/s Siemens
• Steam Parameters up to 300 bar / 600°C / 620°C
• Modular Turbo set design to fit best customer needs
• High reliability & Availability
• Long Inspection intervals
• High efficiency by using modern CFD tools for flow path & blades
![Page 37: 1 WELCOME TO Presentation on New Concepts in Supercritical Turbines Sanjoy Bhattacharya Dy. Genl. Manager, BHEL, Hardwar.](https://reader035.fdocuments.us/reader035/viewer/2022062221/56649c915503460f9494c729/html5/thumbnails/37.jpg)
37
Thank you for a Patient hearing…………