Using Self-Optimizing Control on the Statoil Mongstad HEN

Daniel Greiner EdvardsenMay 27, 2010

NTNU

Confidential

Page 2: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

2

Self-Optimizing Control

• Work by Professor Sigurd Skogestad

Self-optimizing control is said to occur when we can achieve an acceptable loss (in comparison with truly optimal operation) with constant setpoint values for the controlled variables without the need to reoptimize when disturbances occur.

Reference: S. Skogestad, “Plantwide control: The search for the self-optimizing control structure'', Journal of Process Control, 10, 487-507 (2000).

• Using offline analysis to find good controlled variables

Page 3: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

3

Self-Optimizing Control

Acceptable loss ) self-optimizing control

Page 4: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

4

Self-Optimizing Variable

• Properties– Maximizes Tend

– Relies only on cheap temperature measurement, i.e.:• No flow meaurements

• No technical data necessary (HE area, U-values, Cp etc.)

– Best for well designed processes• Because of ΔTlm approximation

Page 5: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

5

Approximation

• If 1/1.4 < Θ1/ Θ2 < 1.4 the error is less than 1%

Source:

Page 6: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

6

Some math

• where J = -Tend is the cost function and g is the steady-state model

• z = [u,x]T, u=MV’s (split) and x = temperatures that varies (Tout)

Page 7: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

7

Some math

• If z is locally optimal then there exists Langrangian multiplier vectors λ such that the first order optimality conditions are satisified(*):

• These equations could be used for control but contain unkwown variables (x, d and λ) which must be eliminated

(*) Nocedal and Wright (2006): Numerical Optimization

Page 8: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

8

Some math• Now define:

• Then, multiplying with the equation on the last slide we get:

• Controlling Jz,red = 0 and g = 0 fully specifies the system at the optimum– BUT: Jz,red still contains unkwown variables in x and d!– Sparse resultants are used to eliminate these.– In practive a toolbox in Maple is used.

λ is eliminated!

Page 9: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

9

Our Self-Optimizing Variable- Case I: 2 heat exchangers in parallel

Page 10: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

10

Our Self-Optimizing Variable- Case I: 2 heat exchangers in parallel

Page 11: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

11

Our Self-Optimizing Variable- Case II: 2 heat exchangers in series and 1 in parallel

Page 12: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

12

Our Self-Optimizing Variable- Case II: 2 heat exchangers in series and 1 in parallel

Page 13: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

13

Mongstad HEN

• Can use both of the presented controlled variables

• Looks very promising

Page 14: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

14

Page 15: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

15

How to solve…• Earlier, only one split and the self-optimizing split (close to optimal)

could be presented like this

Page 16: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

16

How to solve…• Another study with two splits

Page 17: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

17

How to solve…• … where the result could be presented in this way:

Page 18: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

18

How to solve…

• In the Mongstad HEN case we have 7 streams, i.e. 6 splits

Page 19: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

19

234.0

214.0

215.7

210.9

213.4

204.7

234.5

175.2

157.5

192.8

145.4

156.7

P -41

C rude O il

T 0 = 132.9F 0 = 918.2

285.0

252.1

241.1

T o M ainF rac tio nato r

T en d = 266.4

358.6

295.8

275.6

300.4

175.2

178.0

270.3

232.2

245.4

145.4

226.2

175.5

273.8

181.5 223.4256.4

168.1

203.2

161.9

193.1

190.4262.6

244.1

167.5

161.8

A : 86.1

B : 174.6

C : 64.2

D : 128.2

E : 124.9

F : 236.1

G : 103.5

H

213.0H e a t e xc h an g e

248.1F *

Page 20: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

20

How to solve…

• Hard to visualize the results like in the previous cases

• Used fmincon with the constraints:– ci = 0 (six controlled variables)

– Sum(splits) = 1

Page 21: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

21

Controlled variables

Largest stream!

Page 22: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

22

Results

Page 23: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

23

Results

Page 24: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

24

How much is a temperature increase of 0.81°C worth?

• Crude oil @ 213°C: Cp = 2696.8 J/kgK

• Flow rate = 918.2 tonne/h = 255.0 kg/s

• mCp = 688 kW/K

• mCp*0.81 = 557 kW

• Electricity price: 1 NOK/kWh

• Savings = 557 NOK/h = 4.9 million NOK/year

Page 25: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

25

F* split

234.0

214.0

215.7

210.9

213.4

204.7

234.5

175.2

157.5

192.8

145.4

156.7

P -41

C rude O il

T 0 = 132.9F 0 = 918.2

285.0

252.1

241.1

T o M ainF rac tio n ato r

T en d = 266.4

358.6

295.8

275.6

300.4

175.2

178.0

270.3

232.2

245.4

145.4

226.2

175.5

273.8

181.5 223.4256.4

168.1

203.2

161.9

193.1

190.4262.6

244.1

167.5

161.8

A : 86.1

B : 174.6

C : 64.2

D : 128.2

E : 124.9

F : 236.1

G : 103.5

H

213.0H e a t e xc h an g e

248.1F *

Page 26: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

26

F* split

Te

nd [

C]

Split, u0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

180

185

190

195

200

205

210

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1-100

-80

-60

-40

-20

0

20

40

60

80

100

Co

ntr

olle

d v

ari

ab

le, c

[ C

]

SOC-split = 0.499RTO-split = 0.474

Page 27: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

27

RES2-split also a DOF?

Page 28: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

28

H split234.0

214.0

215.7

210.9

213.4

204.7

234.5

175.2

157.5

192.8

145.4

156.7

P -41

C rude O il

T 0 = 132.9F 0 = 918.2

285.0

252.1

241.1

T o M ainF rac tio nato r

T en d = 266.4

358.6

295.8

275.6

300.4

175.2

178.0

270.3

232.2

245.4

145.4

226.2

175.5

273.8

181.5 223.4256.4

168.1

203.2

161.9

193.1

190.4262.6

244.1

167.5

161.8

A : 86.1

B : 174.6

C : 64.2

D : 128.2

E : 124.9

F : 236.1

G : 103.5

H

213.0H e a t e xc h an g e

248.1F *

Assumed cold inlet temperature = Tmeasured + 0.81

Page 29: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

29

H split

Te

nd [

C]

Split, u0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

262

264

266

268

270

272

274

276

278

280

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1-60

-40

-20

0

20

40

60

80

100

120

Co

ntr

olle

d v

ari

abl

e, c

[ C

]

SOC-split = 0.55RTO-split = 0.43 = Optimal split

Flat optimum: Topt = 276.94°C and TSOC = 276.73°C

Page 30: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

30

Conclusion

• Simple control structure

• Close to optimal operation– Demonstrated through several other case studies

• With well-tuned controllers good disturbance rejection can be achieved

Page 31: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

31

To Discuss• Cp-values

• Type of heat exchangers– Flow patterns (correction factor, F)– Large deviations in heat exchangers B1, C1, C2, D1, D2, E1, F2 and H2

Page 32: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.

32

Page 33: 1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.