1-TI-13F21 -F

1
Sheet of Scope Tag Number Vessel No. Line No. Notes Operating Temperature Viscosity Operating Pressure Velocity Density @ Flowing Temp. & Pressure Type Calibration Range Min. Max. Dial Size Dial Color Case Material Stem (Plain/Thread/Union) Stem Type Accuracy Stem or Union Thread Stem Location Lens Stem Diameter Overrange Protection Manufacturer Model No. P&ID No. bar-g 1 2 GENERAL 3 4 5 6 7 PROCESS 8 9 CONDITIONS 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 THERMOMETER 25 26 27 28 29 30 THERMOWELL See Reference Attachment No. 31 Notes: Data Sheet for TEMPERATURE GAUGES 8 " G G70 13F003 1. All Instruments shall be attached with 316SS name plate, stampped with Tag No. & Platform No., and fixed with SS screws or wire. 2. Sensor and thermowell shall be supplied as a single complete assembly, in accordance to GPK-70-0-404-B. 3. Good thermal contact shall be ensured between Sensor and Well. 4. Sensor Imersion length "U" shall suit the thermowell and cover flange length, Stem Extension length "L" shall be 70 mm (mim.). 5. All fixings shall be 316 SS. 1-TI -13F21 * 100-AM-070-E-360-0/200 C-SG-YW-NH- ASHCROFT Bi - Metalic SWP-12-44503-C 0 200 ºC ºC 110 100 ºC 0.02 cP 89.8 kg/m³ 12.1 m/s 1 Yes 6 1.5 times of Full Scale Min. 1% of Calibration Range Every angle Mfr. Standard 1/2 " NPTM Union 316 SS mm 100 Shatter Proof Glass 6 3 mm Project Ref. : Document No. : Rev.: F TotalFinaElf E & P Indonesie PECIKO FIELD DEVELOPMENT PROJECT - PHASE 4 : PCK4 / EPSC2 DESCRIPTION DATE PREPARED REV. CHECKED APPROVED CLIENT SWP-70-44512-D F E D C 5-Nov-03 21-May-03 25-Apr-03 20-Mar-03 Reissued for AFC (As Per Vendor Data) Re Issued - AFC Reissued - Approved for Construction Approved for Construction MNC HK MLD / HK HK HK/LR LR LR LR CL CL CL CL

description

ougo

Transcript of 1-TI-13F21 -F

Page 1: 1-TI-13F21 -F

Sheet of

Scope

Tag NumberVessel No.Line No.

Notes

Operating Temperature

Viscosity

Operating Pressure

Velocity

Density @ Flowing Temp. & Pressure

TypeCalibration Range Min. Max.Dial Size Dial ColorCase MaterialStem (Plain/Thread/Union)

Stem Type

Accuracy

Stem or Union Thread

Stem Location

Lens

Stem Diameter

Overrange Protection

ManufacturerModel No.

P&ID No.

bar-g

12GENERAL34567PROCESS89

CONDITIONS

101112131415161718192021222324

THERMOMETER

252627282930

THERMOWELLSee Reference Attachment No.

31

Notes:

Data Sheet for TEMPERATURE GAUGES

8 " G G70 13F003

1. All Instruments shall be attached with 316SS name plate, stampped with Tag No. & Platform No., and fixed with SS screws or wire.2. Sensor and thermowell shall be supplied as a single complete assembly, in accordance to GPK-70-0-404-B.3. Good thermal contact shall be ensured between Sensor and Well.4. Sensor Imersion length "U" shall suit the thermowell and cover flange length, Stem Extension length "L" shall be 70 mm (mim.).5. All fixings shall be 316 SS.

1-TI -13F21*

100-AM-070-E-360-0/200 C-SG-YW-NH-ASHCROFT

Bi - Metalic

SWP-12-44503-C

0 200ºC ºC

110100 ºC

0.02 cP89.8 kg/m³

12.1 m/s

1Yes

6

1.5 times of Full Scale

Min. 1% of Calibration RangeEvery angleMfr. Standard

1/2 " NPTMUnion316 SS

mm

100

Shatter Proof Glass

63

mm

Project Ref. :Document No. :

Rev.:F

TotalFinaElf E & P IndonesiePECIKO FIELD DEVELOPMENT PROJECT - PHASE 4 : PCK4 / EPSC2

DESCRIPTIONDATE PREPAREDREV. CHECKED APPROVED CLIENT

SWP-70-44512-D

FEDC

5-Nov-0321-May-0325-Apr-0320-Mar-03

Reissued for AFC (As Per Vendor Data)Re Issued - AFCReissued - Approved for ConstructionApproved for Construction

MNCHK

MLD / HKHK

HK/LRLRLRLR

CLCLCLCL