1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap...
-
Upload
tamia-willie -
Category
Documents
-
view
214 -
download
0
Transcript of 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap...
![Page 1: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/1.jpg)
1
The world leader in serving science
Proprietary & Confidential
WiSIM DIA Method Set-upOrbitrap Fusion MS
MS Instrument Control Software v.1.1 SP1
![Page 2: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/2.jpg)
2
WiSIM DIA, how does it work?
• Unique to the Orbitrap Fusion MS: • Three HR/AM SIM are used to cover precursors ions from 400 to 1000
m/z MS1 ultra high resolution quantification
• In parallel with each HR/AM SIM scan, 17 sequential Ion Trap CID MS/MS with 12 amu isolation windows are acquired to cover the associated 200 amu HR/AM SIM mass range MS2 confirmation
SIM 400-600 amu SIM 600-800 amu SIM 800-1000 amu
406 418 430 442 598 606 618 630 642 898 806 818 830 842 998
tSIM Orbitrap
tMS2 Ion Trap
![Page 3: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/3.jpg)
3
WiSIM DIA, how does it work?
SIM 400 – 600 m/z
MS2 No. 1………………MS2 No.17
1st MS1
SIM 600 – 800 m/z
Ion
Tra
pO
T24
0k
3.6
sec
SIM 800 – 1000 m/z
2nd MS1MS2 No. 1………………MS2 No.17
Ion
Tra
p
3rd MS1MS2 No. 1………………MS2 No.17
Ion
Tra
pO
T24
0kO
T24
0k
17 Windows of 12 amu each
17 Windows of 12 amu each
17 Windows of 12 amu each
![Page 4: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/4.jpg)
4
WiSIM DIA Method Set-up at a glance:
SIM• 400-600, 600-800, 800-1000 m/z• 200 amu ion trap isolation width• Resolution@ 240 000• AGC: 3e4• 50 ms Max injection • Profile
tMS2• 12 amu quadrupole isolation• 150-1850 m/z mass range• Ion Trap detection• AGC: 5e4• 35 ms Max Injection • CID 30 • Rapid Scan rate
X3
X3
6 experiments:
406 514418 526430 538442 550454 562466 574478 586490 598502
606 714618 726630 738642 750654 762666 774678 786690 798702
806 914818 926830 938842 950854 962866 974878 986890 998902
![Page 5: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/5.jpg)
5
WiSIM DIA Method Set-up:
6 experiments:-Three HR/AM tSIM-Three Ion trap tMS2 CID
![Page 6: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/6.jpg)
6
Experiment 1:
SIM 400-600 amu SIM 600-800 amu SIM 800-1000 amu
406 418 430 442 598 606 618 630 642 898 806 818 830 842 998
![Page 7: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/7.jpg)
7
Experiment 2:
SIM 400-600 amu SIM 600-800 amu SIM 800-1000 amu
406 418 430 442 598 606 618 630 642 898 806 818 830 842 998
![Page 8: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/8.jpg)
8
Experiment 2:
SIM 400-600 amu SIM 600-800 amu SIM 800-1000 amu
406 418 430 442 598 606 618 630 642 898 806 818 830 842 998
![Page 9: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/9.jpg)
9
Experiment 3:
SIM 400-600 amu SIM 600-800 amu SIM 800-1000 amu
406 418 430 442 598 606 618 630 642 898 806 818 830 842 998
![Page 10: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/10.jpg)
10
Experiment 4:
SIM 400-600 amu SIM 600-800 amu SIM 800-1000 amu
406 418 430 442 598 606 618 630 642 898 806 818 830 842 998
![Page 11: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/11.jpg)
11
Experiment 4:
SIM 400-600 amu SIM 600-800 amu SIM 800-1000 amu
406 418 430 442 598 606 618 630 642 898 806 818 830 842 998
![Page 12: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/12.jpg)
12
Experiment 5:
SIM 400-600 amu SIM 600-800 amu SIM 800-1000 amu
406 418 430 442 598 606 618 630 642 898 806 818 830 842 998
![Page 13: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/13.jpg)
13
Experiment 6:
SIM 400-600 amu SIM 600-800 amu SIM 800-1000 amu
406 418 430 442 598 606 618 630 642 898 806 818 830 842 998
![Page 14: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/14.jpg)
14
Experiment 6:
SIM 400-600 amu SIM 600-800 amu SIM 800-1000 amu
406 418 430 442 598 606 618 630 642 898 806 818 830 842 998
![Page 15: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/15.jpg)
15
WiSIM-DIA advantages
• Low detection limits, high selectivity is achieved using 240,000 SIM scan.
• High sensitivity Ion Trap CID MS2 is used for confirmation of the low abundant components.
• Unsurpassed speed with 2 detectors working in parallel allows for 3.6 s cycle.
• LOD and LOQ down to 10 attomole.• CVs are better than 15 % for 85 % of compounds, better than
20% for 95% of compounds.• Linear dynamic range up to 4 orders of magnitude.
![Page 16: 1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.](https://reader036.fdocuments.us/reader036/viewer/2022081603/56649c7c5503460f94930d96/html5/thumbnails/16.jpg)
16
For More details, please see
Application Note 600
And:
http://planetorbitrap.com/orbitrap-fusion-tips