1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997...

27
1 The New YL9100 HPLC The New YL9100 HPLC Think Smart Work Better Think Smart Work Better

Transcript of 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997...

Page 1: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

1

The New YL9100 HPLCThe New YL9100 HPLC

Think Smart Work BetterThink Smart Work Better

Page 2: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

2

The History of HPLC developmentThe History of HPLC development

Acme 9000

1989 1997 2000

AnalogIntegratorManual

AnalogSoftwareManual

DigitalSoftware-controlAutosampler

YL9100

Network HPLCReliable DesignPowerful CDSFully automatedPDA available

2008

CECE

Page 3: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

3

YL9100 HPLC OverviewYL9100 HPLC Overview

What is the innovated from Acme 9000 HPLC

Superior Performance

Greater Reliability

Excellent Usability

Serviceability and Easy Maintenance

Higher Cost-Effectiveness

Page 4: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

4

YL9100 HPLC – Features 1 YL9100 HPLC – Features 1

Network (LAN) communication - High speed data transfer and real time processing

Higher performance solvent delivery pump - New designed carrier assembly and CAM - Improvement of precision of flow rate

Better UV/Vis detector with new optic design - Seya-Namioka, New Blazed Holographic concave grating

New Detector – Photo Diode Array with excellent sensitivity

Superior PerformanceSuperior Performance

Page 5: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

5

YL9100 HPLC – Features 2 YL9100 HPLC – Features 2

Greater ReliabilityGreater Reliability

Improvement of System components - New designed main parts of Pump, Detectors and Column compartment with very robust materials

Innovative manufacturing process - Three step quality control and assurance system

Page 6: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

6

YL9100 HPLC – Features 3YL9100 HPLC – Features 3

Excellent UsabilityExcellent UsabilityExcellent UsabilityExcellent Usability

Intuitive, intelligent and powerful software - Easy control window for instruments - Harmonization Microsoft’s standards for accessing flies, reviewing data and reports, and other tasks - System Suitability Test with USP, EP and JP - Compliance with 21 CFR Part 11 - Diagnostics and Error detection Automation Perfectly of Analysis work - Startup, analysis operation, shut down, … , and to report generation

Page 7: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

7

YL9100 HPLC – Features 4YL9100 HPLC – Features 4

Serviceability and Easy MaintenanceServiceability and Easy MaintenanceServiceability and Easy MaintenanceServiceability and Easy Maintenance

Better long-life components - New designed the carrier, CAM, needle bearing, seals and belt (with polyurethane) for long-life time - New designed the Deuterium and Tungsten lamp guaranteed 2,000 hours - Semi-permanent peltier in the Column Compartment

Easy Maintenance - Easy replacement and pre-alignment of lamps - Easy replacement of sample cell assembly - Diagnostics procedure by software

Page 8: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

8

YL9100 HPLC – Features 4YL9100 HPLC – Features 4

Higher Cost-effectivenessHigher Cost-effectivenessHigher Cost-effectivenessHigher Cost-effectiveness

Cost between YL and “A”

UV Detector YL9100 HPLC “A” company

Wavelength range 190-900 nm 190-600nm

Baseline Noise ± 0.5 x 10-5 AU at 254 nm ± 0.75 x 10-5 AU at 254 nm

Baseline Drift <1 x 10-4 AU at 254 nm 3 x 10-4 AU/hr at 254 nm

Data acquisition rate Max 50 Hz Max 13Hz

Configuration YL9100 HPLC “A” company

Isocratic System 15,400$ 16,000$

Full QLPG 33,700$ 33,000$

Better performance between YL and “A”

Plus Two Years Warranty…….

Page 9: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

9

YL9100 HPLC – ModulesYL9100 HPLC – Modules

What is the innovated from each module

Vacuum Degasser

Pump

Column Compartment

UV/Vis Detector

PDA Detector *NewNew

Page 10: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

10

YL9100 HPLC – Modules -VDYL9100 HPLC – Modules -VD

YL9101 Vacuum Degasser- - No fluctuationNo fluctuation, shorten warming upshorten warming up

Number of channel : 4 CHs

Maximum degassing range: 10ml/min

High capacity of chamber: 925ul per channel

Excellent compatibility with Toxic chemicals

: degassing membrane with Teflon® AF

Robust ZHCR® vacuum pump – 220 million cycle

Safety & maintenance : Vacuum Error detection

Wide range of Line Voltage : 100-240VAC, ±10%, Wide range

Line frequency : 50/60Hz, ±5%

Power consumption : 20W

Page 11: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

11

YL9100 HPLC – Modules – YL9100 HPLC – Modules – QP/BP/IPQP/BP/IP

YL9110 Quaternary Pump

YL9111 Binary Pump

YL9112 Isocratic Pump

New design of mechanical parts of pumps

Compressibility Compensation technologyCompressibility Compensation technology

Semi-automatic Prime/Purge

Built-in Leak sensor

Wide flow range by each check valve with two balls

Ultra robust carrier, bearing, belt, etc

A new Binary Pump in a module

Page 12: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

12

YL9100 HPLC – Modules – YL9100 HPLC – Modules – BPBP

YL9111 Binary Pump

A New Pump for higher throughput and reproducibility

The best pump for High Pressure Gradient System

Built-in Large capacity static mixer

X2 Parallel dual-plunger

Attractive price compared to QP

Page 13: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

13

YL9100 HPLC – Modules – YL9100 HPLC – Modules – QP/IPQP/IP

YL9110 Quaternary Pump

Attached 4-way mixing valve to QP

YL9112 Isocratic Pump

Improved Isocratic Pump with parallel dual-plunger

Easy upgraded from IP to QP

Page 14: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

14

YL9100 HPLC – Modules -CCYL9100 HPLC – Modules -CC

YL9130 Column Compartment- - Powerful temperature controlPowerful temperature control

The best temperature precision: ±0.05°C

Powerful Cooling is the standard: down to 4 °C

Preheating available

Semi-automatic injector/Switching valve: up to 1

(option: max. 2)

Column capacity: 300mm – 4ea

Leak sensor

40 steps programming

Page 15: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

15

YL9100 HPLC – Modules -UVDYL9100 HPLC – Modules -UVD

YL9120 UV/Vis Detector- - Excellent sensitivityExcellent sensitivity

New designed Optic structure: Seya-Namioka

New Blazed Holographic Concave Grating

Excellent Data acquisition rate: up to 50 Hz

Long-life D2 lamp

Advanced band width: 5.5 nm

Excellent Sensitivity: <±0.5 x 10-5 AU at 254nm

Integrated cell and slit assembly

Greater cooling of the lamp’s thermal environment

Tested flow cell guarantee up to 1,500 psi(103 bar)

Optimal cell volume and path length for analytical

method development and QC/QA

Leak sensor

Page 16: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

16

YL9100 HPLC – Modules -UVDYL9100 HPLC – Modules -UVD

YL9120 UV/Vis Detector

What is the Seya-Namioka monochromator

- To attach New Blazed Holographic Concave Grating

- Extremely low stray light

- Highest light intensity

- Reduced astigmatism

- Very compact design and size

- More serviceability

- High performance beam splitter

- New designed an integrated cell+slit assembly

- Excellent band width, 5.5nm

Page 17: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

17

YL9100 HPLC – Modules -PDAYL9100 HPLC – Modules -PDA

YL9160 PDA Detector

Optimum wavelength resolution: 1,024 diodes

Wide range from 190 to 950 nm

Highest Sensitivity

<±1.0 x 10-5 AU at 254nm, 2 sec rise time

<±2.0 x 10-5 AU at 254nm, 1 sec rise time

Fast data acquisition: 50 Hz

Greatest drift level

<2.0 x 10-4 AU/h at 254nm, Baseline correction

<1.0 x 10-3 AU/h at 254nm

- Highest Sensitivity- Highest Sensitivity

Page 18: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

18

YL9100 HPLC – Modules -RIDYL9100 HPLC – Modules -RID

YL9170 RID

- For universal detection, GPC and sugar analysis- For universal detection, GPC and sugar analysis

RI Range : 1.00 ~ 1.75 RIU

Noise : < ±1.3 x 10-8 RIU

Linear dynamic range : 80 x 10 -5 RIU

Drift range : 0.8 x 10 -7 RIU/h

Flow rate range : 0.2 ~ 3.0 ml/min(analytical)

Narrow-bore & Semi-prep also available

Cell pressure : 6 kg/cm2(84 psi)

Page 19: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

19

YL9100 HPLC – Modules -ELSDYL9100 HPLC – Modules -ELSD

YL9180 ELSD / YL9181 ELSD

- For universal detection, Better sensitive than RID- For universal detection, Better sensitive than RID

Universal detector to analyze components which do not have UV absorption, cannot be separated with an isocratic solvent and must use a gradient elution, which cannot be used with a refractive index detector. Only mobile phases without any buffers should be used

Display: 2 line x 20 character per line VFDL Operating Conditions: Intended for indoors operation only. 60°F to 85°F and <90% R.H. non condensing Evaporative Zone Temperature: Ambient to 120°C Nebulization Chamber Temperature: Ambient to 60°C(10-70 °C for 9181) Gas Requirement: 65psi ± 5 psi Nitrogen or other inert gas Gas Consumption: Approximately 2.5 SLPM Liquid Flow Rate: 0.25 ml/min. to 3 ml/min (0.2mL/min to 5mL/min for 9181) Electrical Requirement: 120 V AC, 50/60 Hz or 240 V AC, 50/60 Hz 600 Watts Wetted Materials: Stainless Steel, glass, Anodized Aluminum, Teflon Light Source: 670 nM Laser Diode, <5 m W Detector: Hermetically Sealed Photo-Diode/Operational Amplifier Output Signal: 0-5 VDC, Communications: RS-232

Page 20: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

20

YL9100 HPLC – Modules -ASYL9100 HPLC – Modules -AS

YL9150 Autosampler

- Fully automated work- Fully automated work

Sample capacity :96 standard vials

Option: 384 vials, 24 vials(10ml for prep)

Sample loop: 100ul(standard)

Injection cycle time: <60 sec

Injection: full loop, partial loop and ul pickup

RSD <=0,3% at full loop

<=0.5% at partial loopfill inj.

<=1.0% at uL pickup inj.

Carry-over < 0.05%

Option: Built-in Peltier cooling (4oC ~ ambient –3oC)

Page 21: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

21

YL9100 HPLC – Modules -CDSYL9100 HPLC – Modules -CDS

YL-Clarity CDS

- Intelligent and Powerful Chromatography Data Station- Intelligent and Powerful Chromatography Data Station

1

MeasuringFour Instruments up to 12 detectors.

2

Post-runAutomatically displays, prints, exports and starts other programs

Page 22: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

22

YL9100 HPLC – Modules -CDSYL9100 HPLC – Modules -CDS

3Column performanceMethod validationBy USP, EP and JP

4User accountsSets up access rights and passwords

5Audit trailRecords selected events and operations into a special file.

6Electronic signatureEach chromatogram can be signed electronically.

7Networked SolutionClarity files can be accessed from networked computers using Clarity Offline software.

8Great CompatibilityWindow XP/2000.Window Me/98, and Window Vista (32bit) is available

Page 23: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

23

YL9100 HPLC – Modules -CDSYL9100 HPLC – Modules -CDS

YL-Clarity CDS

Perfectly compliance with 21CFR Part 11

GPC option available

System Suitability Test option available(Method validation)

PDA module option available: 3-D data analysis

Software Validation option available: Software OQ

Page 24: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

24

YL9100 HPLC – Competition vs AYL9100 HPLC – Competition vs A

Specifications of YL9100 VS “A” company low cost model

YL9100 “A” 1120

Degassing 4-channel 2-channel

Pumps Isocratic/QLPG/BHPG Isocratic/QLPG

UV/Vis Detector

Wavelength range 190-900 nm 190-600nm

Baseline Noise ± 0.5 x 10-5 AU at 254 nm ± 0.75 x 10-5 AU at 254 nm

Baseline Drift <1 x 10-4 AU at 254 nm 3 x 10-4 AU/hr at 254 nm

Data acquisition rate Max 50 Hz Max 13Hz

PDA Available no

Column Compartment

Temperature range 4(cooling)-90oC Ambient - 60oC

Temperature Stability ± 0.05℃ ± 0.15℃

Page 25: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

25

YL9100 HPLC – Competition vs AYL9100 HPLC – Competition vs A

Price of YL9100 VS “A” company low cost model

YL9100 “A” 1120

Manual Isocratic

HPLC system

15,400$ 16,000$

Automatic Quaternary

Gradient System

33,700$ 33,000$

Better performance, Same priceWhat is your choice tomorrow?

Page 26: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

26

YL9100 HPLC – Competition vs SYL9100 HPLC – Competition vs S

Specifications of YL9100 VS “S” company Pro…

YL9100 “S” Pro…

Degassing 4-channel 3-channel or 5-channel

Pumps Isocratic/QLPG/BHPG Isocratic/QLPG/BHPG

UV/Vis Detector

Wavelength range 190-900 nm 190-700nm or –900nm

Baseline Noise ± 0.5 x 10-5 AU at 254 nm 0.5 x 10-5 AU

Baseline Drift <1 x 10-4 AU at 254 nm 1 x 10-4 AU/hr

Data acquisition rate Max 50 Hz Max 20Hz ??

PDA 1,024 diodes 512 diodes

Column Compartment

Temperature range 4(cooling)-90oC 4(cooling) - 85oC

Temperature Stability ± 0.05℃ 0.1℃

Page 27: 1 The New YL9100 HPLC Think Smart Work Better. 2 The History of HPLC development Acme 9000 19891997 2000 Analog Integrator Manual Analog Software Manual.

27

YL9100 HPLC – Competition vs SYL9100 HPLC – Competition vs S

Price of YL9100 VS “A” company low cost model

YL9100 “S” Pro…

Automatic Quaternary

Gradient System

33,700$ 41,000$

Automatic Binary

Gradient System

36,800$ 47,000$

Same performance, Better priceWhat is your choice tomorrow?