Stationary Diesel Generator / Catalytic Converter Emission
Control Evaluation
Power Systems Division
Naval Surface Warfare Center, Crane, IN.
Cinergy Ventures, Cincinnati, OH
Presenter: Brian Fillingim, NSWC Crane
![Page 2: 1 Stationary Diesel Generator / Catalytic Converter Emission Control Evaluation Power Systems Division Naval Surface Warfare Center, Crane, IN. Cinergy.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d165503460f949ec490/html5/thumbnails/2.jpg)
2
Emission Limitation
• Federal Standards for NonRoad Emission Requirements – Tier I Phase - 1996 to 2000– Tier 2 / Tier 3 Phase - 2000 to 2008– Limited Annual Hours to Remain With In
Air Polution Standards for Total Emissions
![Page 3: 1 Stationary Diesel Generator / Catalytic Converter Emission Control Evaluation Power Systems Division Naval Surface Warfare Center, Crane, IN. Cinergy.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d165503460f949ec490/html5/thumbnails/3.jpg)
3
![Page 4: 1 Stationary Diesel Generator / Catalytic Converter Emission Control Evaluation Power Systems Division Naval Surface Warfare Center, Crane, IN. Cinergy.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d165503460f949ec490/html5/thumbnails/4.jpg)
4
Method of Reduction
• Selective Catalytic Reduction (SCR) Process
• Exhaust Catalyst with Anhydrous Ammonia (NH3) Injection “Proof of Concept”
![Page 5: 1 Stationary Diesel Generator / Catalytic Converter Emission Control Evaluation Power Systems Division Naval Surface Warfare Center, Crane, IN. Cinergy.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d165503460f949ec490/html5/thumbnails/5.jpg)
5
SCR Process
SCR Reaction Chemistry
4NO + 4NH3 + O2 = 4N2 + 6H2O
6NO2 + 8NH3 + O2 = 7N2 + 12H2O
High Temp and Excess NH3
4NH3 + 5O2 = 4NO + 6H2O
4NH3 + 3O2 = 2N2 + 6H2O
![Page 6: 1 Stationary Diesel Generator / Catalytic Converter Emission Control Evaluation Power Systems Division Naval Surface Warfare Center, Crane, IN. Cinergy.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d165503460f949ec490/html5/thumbnails/6.jpg)
6
Test Setup
• Caterpillar Model 3306 Diesel Generator Set - 250 Kilowatt (kW)
• Catalytic Converter in place of Stock Muffler– Catalyst Design and Formulation by Catalytic
Solutions Inc., Oxnard, CA– Catalyst Housing and Integration by
ArvinMeritor Inc, Columbus, IN
• Manual Setting for NH3 Injection Flow Rate into Engine Exhaust
![Page 7: 1 Stationary Diesel Generator / Catalytic Converter Emission Control Evaluation Power Systems Division Naval Surface Warfare Center, Crane, IN. Cinergy.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d165503460f949ec490/html5/thumbnails/7.jpg)
7
Caterpillar Model 3306
![Page 8: 1 Stationary Diesel Generator / Catalytic Converter Emission Control Evaluation Power Systems Division Naval Surface Warfare Center, Crane, IN. Cinergy.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d165503460f949ec490/html5/thumbnails/8.jpg)
8
Muffler vs Catalytic Converter
![Page 9: 1 Stationary Diesel Generator / Catalytic Converter Emission Control Evaluation Power Systems Division Naval Surface Warfare Center, Crane, IN. Cinergy.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d165503460f949ec490/html5/thumbnails/9.jpg)
9
Test Procedure
• Daily Six to Nine Hour Runs
• Four to Six Samples per Test Run of:
O2, CO, NO, NO2, SO2
• Temperature (Pre Converter, Post Converter, Catalyst and Ambient)
• Third Party Verification of Emission Measurements by GE Energy Serivces Inc
![Page 10: 1 Stationary Diesel Generator / Catalytic Converter Emission Control Evaluation Power Systems Division Naval Surface Warfare Center, Crane, IN. Cinergy.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d165503460f949ec490/html5/thumbnails/10.jpg)
10
Results
• 556 Engine Hours • 476 Hours with NH3 Injection• Final 350 Hours at 90 percent Load (225
kW) with NH3 Injection• Maximum NOx Reduction with 13 to 16
standard liters per minute (slpm) NH3 injection (0.8 NH3/NOx) at 90 percent Load
• GE Energy Services Inc. measured Comparable Data and No Indications of Secondary Emissions
![Page 11: 1 Stationary Diesel Generator / Catalytic Converter Emission Control Evaluation Power Systems Division Naval Surface Warfare Center, Crane, IN. Cinergy.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d165503460f949ec490/html5/thumbnails/11.jpg)
11
Conclusions
• NH3 Injection and Catalyst Combination Reduced NOx by Approximately 90 percent
• Further Evaluation in Colder Ambient Temperatures Indicated
• Further Development and Evaluation of NH3 Controllers is Indicated
![Page 12: 1 Stationary Diesel Generator / Catalytic Converter Emission Control Evaluation Power Systems Division Naval Surface Warfare Center, Crane, IN. Cinergy.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d165503460f949ec490/html5/thumbnails/12.jpg)
12
For More Details Contact:
• Raj Malyala - Catalytic Solutions Inc., Oxnard, CA (805) 486-4649 x1727 [email protected]
• Jim Lefeld - Cinergy, Cincinnati, OH 513-287-2435 [email protected]
• Brian Fillingim - NSWC Crane, IN 812-854-2361 [email protected]