1
Paralleling Radiographic Exposures: The Preferred Method
XCP
2
Key Terms to Know
• Parallel• Intersecting• Perpendicular• Right angle• Long axis of the tooth• Central ray
Basic Rules of Paralleling- Know
• Film placement• Film position• Vertical angulation• Horizontal angulation• Film exposure
3
Principles of Paralleling Technique
A. The film is placed in the mouth parallel to the long axis of the tooth being radiographed
B. The central ray of the x-ray beam is directed perpendicular to the film and long axis of the tooth
C. A film holder must be used to keep the film parallel with the long axis of the tooth
Correct Incorrect
4
Different Film Holding Devices
• Rinn XCP
• Stabe Bite-Block
Anterior Posterior
Parallel to the Long Axis of Tooth
Define long axis of tooth- *teeth to do not sit in the mouth straight up & down
5
6
CORRECT
Long Axis of Tooth
7
Object and film/receptor are not parallel = distortion
8
Principles of Paralleling Technique
Remember:• To achieve parallelism, the film must be placed away from the tooth and toward
the middle of the cavity• Object receptor (or film) distance must be increased to keep the film parallel to
the long axis of the tooth• Because of the distance from the film to the tooth, magnification and loss of
definition result. To compensate, the target receptor distance must be increased (16 inch cone used-known as “long cone technique”). This results in less magnification and increases definition.
9
Object-Film-Distance v/s Target-Film-Distance
Compare/Contrast object-receptor-distance & target-receptor-distance
(tooth to film) (anode/focal spot to film)
*Both must be increased when using the paralleling technique*
10
11
REVIEW- Protection Measures for the Patient
Source–film distance. The longer the source–film or receptor distance, the more parallel the rays and the less tissue exposed. Note the beam size at the patient’s skin entrance is 2.75 in. (7 cm) for both source–film distances; it is the exit beam size that increases to expose a larger area when using the shorter source–film distance. Remember from safety module- 16” cone preferred due to less divergence of x-ray beam as exits.
Challenges with Placement of Holder
13
Conditions (i.e. crowding, mal-aligned teeth, missing teeth, torus, size of mouth, vault of palate, presence of unerupted 3rd molars, & variations in occlusal relationship) affect ideal placement
If the holder cannot be placed correctly- the beam will not be aligned correctly = errors (distortion, elongation, foreshortening, etc…)
Patient conditions & cooperation do not always match what textbook teaches!
14
Modifications of Placement (see text)
Shallow palate (p. 193- <than 20- degrees tilt acceptable; if more -must modify)
Maxillary/Mandibular tori (p. 207-209)
Muscle attachments (p. 208-210)
Missing teeth (use cotton rolls to stabilize)
15
When holder tilted more than 20-degrees due to patient conditions (and therefore NOT parallel to long axis) VERTICAL ANGULATION needs to be INCREASED 5-15 degrees more than indicated (therefore NOT lined up with circle of XCP)
**However, if angulation too excessive = incisal edges missing from image & foreshortening**If angulation inadequate (not enough) = apices missing & elongation
16
Film Placement for each area- *review handout & text
17
9-10
22
6 7-8 11
27 23- 26
ANTERIOR
18
Film Placement for Anterior
7 Size #1 films used for anteriors Maxillary (4) - canine (both sides) - lateral/central incisors (both sides)
Mandibular (3) - canine - lateral/central incisors
19
Film Placement for Posterior
8 (Size #2) films are taken in the posterior
Maxillary (4)- premolar- molar
Mandibular (4)-premolar
-molar
20
Must see distal of canine on premolar PACenter 2nd molar
Center canines
Center central incisors
Need to see wisdom teeth
Center central/lateral contact
21
Order for FMS
When using the paralleling technique, an exposure sequence, or definite order for periapical film placement and exposure, must be followed.Keep track of exposures on tray cover!
This prevents Errors Loss of timeExposing the patient unnecessarily
22
Order for FMS
I. Start with anterior exposure sequence (Size #1 film used)– Seven films are taken– Begin with maxillary right canine-expose all
maxillary right maxillary left– Move to mandibular area-begin with mandibular
left canine and expose remaining films left to right
23
Order for FMS Cont’d2. Posterior exposure sequence (Size #2 film used)
-always expose the premolar first in all areas-8 films are taken-begin with maxillary right premolar then molar-move to mandibular left –premolar then molar (you do not have to reassemble XCP for this area)-reassemble XCP and move to maxillary left-premolar then molar-finish with mandibular right area
24
Order for FMS Cont’d
3. Lastly, take Bitewing radiographs (Size #2 film used)- 4 radiographs are usually taken; horizontal BW unless otherwise indicated
- BW part of FMS
25
Advantages of Paralleling Technique
• Produces images with dimensional accuracy• Is simple and easy to learn and use• Is easy to standardize and can be accurately
repeated
26
Disadvantages of Paralleling Technique
• Accurate film placement may be difficult at times for the radiographer to achieve
• Film placement can sometimes be difficult for the patient to tolerate (it hurts!)
• Not disposable- most holders have to be sterilized
• Rings are a “guide” only- radiographer must have skill to access accuracy
27
Don’t forget to put the dot at the incisal edge now!
Review helpful hints page 211!