1 ORISS Isomer and Isobar Spectrometer and Separator for Study of Exotic Decays A. Piechaczek for...
-
Upload
zaire-turkington -
Category
Documents
-
view
216 -
download
2
Transcript of 1 ORISS Isomer and Isobar Spectrometer and Separator for Study of Exotic Decays A. Piechaczek for...
1
ORISS Isomer and Isobar Spectrometer and Separator for
Study of Exotic Decays
A. Piechaczek for the
2
EMIS 2007
UNIRIB Consortium
• The purpose is to provide a nuclear research facility at ORNL for consortium members
• Consortium members:
3
EMIS 2007
• Our Deliverable is Science – Nuclear Physics
• We do research• We give scientific reports at meetings• We train students
• UNIRIB, with ORISE and ORAU, provides a university atmosphere in a national laboratory
4
Motivation to build ORISS – Oak Ridge Isomer/Isobar Spectrometer and Separator:
• Decay studies often possible from yield considerations, but limited by background from isobaric/isomeric contamination
• Need high resolution separator for background suppression
ORISS predicted performance:• High mass resolving power, M/∆M up to 400,000 (FWHM)• Almost complete Suppression of neighboring isobar• High efficiency ~ 50%• Chemistry independent• Transportable• Cost effective
… use Multi-pass Time of Flight principle!
5
EMIS 2007
Multi-pass Time-of-Flight system: concept
MTOF Spectrometer: Spectrum taken with MCP
MTOF Separator: Physical separation using fast electrostatic gate (Bradbury Nielsen gate)
DToF = ½ ToF DM/M
Pulsedion source
MCP detectororelectrostaticgate
1st Electrostatic Mirror 2nd Electrostatic Mirror
Individual electrodesPulsedentry electrode
Pulsedexit electrode
6
1.0E+00
1.0E+01
1.0E+02
1.0E+03
1.0E+04
1.0E+05
1.0E+06
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3
g-Sem-SeAsg-Gem-GeGag-Znm-Zn
What you could do with mass resolving power of 400,000:• resolve all isobars• resolve isomers M/DM < 200,000 (470 kev @ A=100)
SeAs
Ge Ga
Zn
A=77
Se.161
Zn.772
Ge.160
T – T0 [microseconds]
7
8
Strawman layout of ORISS at UNISOR
RF-cooler and buncher
RB Ion Source
UNISOR mass separator“pre-separator”
ORISSBeta and
Gamma rayDetectors
Beam diagnostics,electrostaticdecelerator
9
Applications of ORISS
Decay spectroscopy with pure sources for p-rich and n-rich
Decay spectroscopy of isomers with sufficient excitation
Survey searches for isomers
Modular Total Absorption Spectrometer - GT strength functions
Future: masses/mass differences
Future: RIB injector
10
Physics…
Regions around 100Sn, 132S, 78NiRegions around
100Sn132Sn78Ni
11
Physics application: Decay Heat and spectroscopy for advanced nuclear fuel cycle
Many critical measurements can be performed at UNISOR with ORISSAll critical measurements can be performed at UNISOR with ORISS and He-Jet ion source
Elements available with He-Jet ion source