1 Luca Stanco - INFN Padova
Luca Stanco - INFN PadovaKrakow, 28 September 1999
Setup reminder Status of the Limited Streamer Tubes (LST) Triggers Efficiencies Y2K, online hang-up etc.
2 Luca Stanco - INFN Padova
Elettrons
Protons
RM
UO
N
BMUON
3 Luca Stanco - INFN Padova
~ 3 600 LSTs (with lenght from 0.7 to 10.2 m)
~ 43 000 8-bit analog channels ~ 29 000 digital channels
Area detector > 2 000 m2
Technical Coordinator: Riccardo Brugnera
Web-master: Vincenzo Chiochia
Resolution: 1 mm in the “strip” view 3 mm in the “wire” view
4 Luca Stanco - INFN Padova
Mortality...
year BMUI BMUO RMUI RMUO Total Ch72
1994 78 59 41 23 201 34
1995 - - - - - -
1996 78 59 42 23 202 36
1997 79 59 45 33 216 25
1998 81 66 50 41 238 25
1999 81/708 66/1502 50/480 41/704 238/3394 25/184
plus ~ 68 LST in trip for 10-40% of time
plus ~ 10 LST in trip for 10-40% of time
5 Luca Stanco - INFN Padova
DeadDead LSTLST’s are normallynormally switched offswitched off
SimulationSimulation in the in the Monte CarloMonte Carlo via an via an EAZEEAZE job: job:
to evaluate efficiencyefficiency dependence (small effect: 5%)
effi
cien
cy
BMUON
RMUON
- MC ideal- - MC with dead LST
6 Luca Stanco - INFN Padova
Slot 8: Elastic Slot 10: Inner BMUONBMUONSlot 11: Inner RMUONRMUONSlot 14: Outer BMUONBMUONSlot 15: Outer RMUONRMUON
• GLOMU• GLOEXO
InnerOuter
7 Luca Stanco - INFN Padova
rates...
1 b for L = 10*1030 10 Hz (most of the runs)
8 Luca Stanco - INFN Padova
with INNER chambers
and with ISOMU: Calorimeter regions
9 Luca Stanco - INFN Padova
rates
INNER
OUTER
10 Luca Stanco - INFN Padova
GLOMU rates
30 nb for L = 10*1030 0.03 Hz
cosmics
11 Luca Stanco - INFN Padova
independent setup: efficiency vs HV
working value to reduce trips
12 Luca Stanco - INFN Padova
HV: 4700
HV: 4550
include inefficiency factor on single LSTin the Monte Carlo (15%)
100%
100%
88%
75%
13 Luca Stanco - INFN Padova
- MC ideal- - MC with dead LST and 15% factor for HV
effi
cien
cy
BMUON
RMUON
15% inefficiency coherent with analysis of single track segment !
14 Luca Stanco - INFN Padova
Check efficiencyefficiency with DATADATA themselves !Two independent analysis on 2 track +- clean events
(3 different set of events, depending of the trigger)
BMUON
SET 1
SET 2
15 Luca Stanco - INFN Padova
… much more in Alessandro Bertolin’ talk
this afternoon
Monte Carlo is off of an overall factor !
A few investigations performed.A few investigations performed.Not yet found out the reason...Not yet found out the reason...
16 Luca Stanco - INFN Padova
VMS computer for DAQ• patch from DEC (and spare VAX from DELPHI available)
• upgrade on going ...
Slow Control with OS9 (version 2.3 NOT good)• manual patch (bring time back, uff !) …• upgrade to 3.03 ?
17 Luca Stanco - INFN Padova
Time for AbortingAborting as function of RunRun ...
problem while Aborting Run ?
18 Luca Stanco - INFN Padova
Distribution of Time for Aborting Aborting ...
for last positron runs...
19 Luca Stanco - INFN Padova
• Good general behaviour of the detector
• Triggers under control
• Efficiency studies on the way on
• Few upgrades needed for next millenium
Good perspectives for next millenium Runs