HVAC 214 Electricity For Oil Heat
Fan Center Relays
![Page 2: 1 HVAC 214 Electricity For Oil Heat Fan Center Relays.](https://reader036.fdocuments.us/reader036/viewer/2022082710/56649dbd5503460f94ab00b6/html5/thumbnails/2.jpg)
2
Fan Center Relay
![Page 3: 1 HVAC 214 Electricity For Oil Heat Fan Center Relays.](https://reader036.fdocuments.us/reader036/viewer/2022082710/56649dbd5503460f94ab00b6/html5/thumbnails/3.jpg)
3
Fan Center Relays
• Designed to provide low voltage control of blower motors and auxiliary circuits.
• Designed to provide a good junction point for other circuits.
• Used on heating systems with air conditioning.
![Page 4: 1 HVAC 214 Electricity For Oil Heat Fan Center Relays.](https://reader036.fdocuments.us/reader036/viewer/2022082710/56649dbd5503460f94ab00b6/html5/thumbnails/4.jpg)
4
Fan Center Relays
• Contain the following components:
– A low voltage transformer (step down from 120 to 24 volts)
– A pre-wired multifunction switching relay
– A Low voltage terminal board.
![Page 5: 1 HVAC 214 Electricity For Oil Heat Fan Center Relays.](https://reader036.fdocuments.us/reader036/viewer/2022082710/56649dbd5503460f94ab00b6/html5/thumbnails/5.jpg)
5
Fan Centers
• Sometimes used when there are two transformers, one on the heating equipment and one on the cooling equipment.
• These transformers must be isolated from each other based on whether the thermostat is calling for cooling or heating.
![Page 6: 1 HVAC 214 Electricity For Oil Heat Fan Center Relays.](https://reader036.fdocuments.us/reader036/viewer/2022082710/56649dbd5503460f94ab00b6/html5/thumbnails/6.jpg)
6
Fan Center Wiring Connections
• Connections:– R is output power from the internal
transformer– W is the junction point for W from tstat
and W from equipment– G is the connection from G from the
thermostat– Y is a junction point from for Y from the t-
stat– C is common from internal transformer
![Page 7: 1 HVAC 214 Electricity For Oil Heat Fan Center Relays.](https://reader036.fdocuments.us/reader036/viewer/2022082710/56649dbd5503460f94ab00b6/html5/thumbnails/7.jpg)
7
Thermostat calls for heat
• During a call for heat, the normally closed relay contact for the low speed blower stays closed and the blower is controlled by a Fan/Limit switch mounted in the furnace plenum.
![Page 8: 1 HVAC 214 Electricity For Oil Heat Fan Center Relays.](https://reader036.fdocuments.us/reader036/viewer/2022082710/56649dbd5503460f94ab00b6/html5/thumbnails/8.jpg)
8
Call for heat
Low speed blower wire goes through N/C contact onto the Fan/Limit
![Page 9: 1 HVAC 214 Electricity For Oil Heat Fan Center Relays.](https://reader036.fdocuments.us/reader036/viewer/2022082710/56649dbd5503460f94ab00b6/html5/thumbnails/9.jpg)
9
The thermostat call for cooling
• During a call for cooling, the thermostat closes R to G which energizes the relay coil. When the coil is energized, the N/O contact closes and allows the blower to operate on high speed.
![Page 10: 1 HVAC 214 Electricity For Oil Heat Fan Center Relays.](https://reader036.fdocuments.us/reader036/viewer/2022082710/56649dbd5503460f94ab00b6/html5/thumbnails/10.jpg)
10
Call for cooling The high speed blower wire goes through the N/O contact which closes when the coil is energized.
Thermostat closes R to G & R to Y
![Page 11: 1 HVAC 214 Electricity For Oil Heat Fan Center Relays.](https://reader036.fdocuments.us/reader036/viewer/2022082710/56649dbd5503460f94ab00b6/html5/thumbnails/11.jpg)
11
Fan Center
• The W, Y, and any additional terminals are just junction points.