Doc1 - nakhoncity.org · Title: Doc1 Subject: Doc1 Keywords: Doc1 Created Date: 6/8/2015 8:46:20 AM
1 Degaussing Doc1
description
Transcript of 1 Degaussing Doc1
DEMAGNETIZINGON THE ROTOR GENERATOR, HP / LP STEAM TURBINE , BEARINGS, COUPLING, JOURNAL
SHAFT, ETC
GE TURBINE GENERATOR 180 MW
SiswantoPower Generation Services
www.sispowergeneration.blogspot.comEmail: [email protected], [email protected]
Mobile: +62 81311422270
Page (s) : 1 of 14
File documents C:\SIS_File\Sis SEMINAR\MATERI SEMINAR\Printing_Doc\Tot_Maint\POWERGENERATION\DEGAUSSING\DEGAUSSING.docx
Doc. Issued by Siswanto Email: [email protected], [email protected] Dtd. Doc issue Jan 10, 2009 Blog: www.sispowergeneration.blogspot.com Edited / Rev Oct 2011 Mobile: +62 81311 422270
Project ExperienceDemagnetizing on GE Frame 9, 180 MW
Steam Turbine and Rotor Generator
A. Medan Magnet
Medan magnet dihasilkan oleh aliran arus listrik yang berlangsung dalam jangka waktu yang
relative lama dan dapat di presentasikan sebagai induksi magnetic dalam satuan “lines” atau “flux-
lines.
Satuan dari magnetic flux adalah “Maxwell (lines), besarnya “lines” yang mengalir melalui suatu
luasan material di sebut Rapat flux magnetic (B) , yang arahnya tegak lurus terhadap induksi
magnetic “flux-lines”, kemudian rapat flux / “flux density” (B) / cm2 disebut dengan “gauss”
B. Magnetisasi di dalam mesin
Magnetisasi akibat aliran arus listrik atau sebab lain di dalam mesin dapat menyebabkan gangguan
serius pada mesin, seperti, dapat menyebabkan kerusakan pada bearing, seal, gear, coupling dan
journal bearing, casing, dll.
Untuk mencegah terjadinya kerusakan pada bagian mesin yang seharusnya tidak dialiri arus listrik,
seperti pada bagian bagian tsb, normalnya pada bagian-bagian seperti bearing, dilengkapi dengan
“insulation-bearing”, dan pada shaft dilengkapi dengan “shaft-grounding brush”.
Pada generator, yaitu mesin yang merubah tenaga mekanik melalui medan magnetic rotor winding
menjadi tenaga listrik, rapat medan magnetic di dalam air gap generator dan motor listrik berkisar
antara 7 KGauss – 9 KGauss.
Turbine, compressor atau rotating machine yang lain, dibentuk dari magnetic steel yang pada
dasarnya adalah merupakan material magnetic yang dapat menghantarkan listrik akibat induksi,
dan akan menghasilkan “eddy current” dan circulating current,
Arus listrik yang mengalir dapat berupa arus searah (DC) atau arus bolak balik (AC), dan dapat
menimbulkan terjadinya spark atau discharge. Spark atau discharge didalam rotating part dapat
merusak permukaan rotating parts , seperti bintik-bintik, jalur listrik (electrical tracking), bahkan jika
sparknya besar dapat menyebabkan rotating part meleleh.
Banyak hal yang dapat menyebabkan machinery parts terinduksi dan menjadi magnet, a.l:
- Medan magnet sisa, karena peletakan part tsb di area yang memiliki medan magntic yang
sangat kuat
- Mechanical shock dan gesekan
- Induksi aliran arus listrik yang besar, misal; karena gangguan arus listrik (electrical fault),
sambaran petir, rectifier supply
- Electrostatic discharge
- Electrical welding pada pipa2 atau material lain yang berhubungan dengan mesin, dimana
sistim groundingnya tidak sempurna.
- MPI test
File doc
Doc. IssDtd. DoEdited /
C.
Magnet
satuan
Type2 g
Digital
D.
Degaus
timbul d
1.
2.
3.
4.
5.
6.
Magnet
sebabk
shaft” ti
yang se
atau tur
Medan
electric
Magnet
peluma
menyeb
cuments
sued by c issue Rev
Field Meas
tic field dap
ukuran “ga
gauss mete
gauss mete
Degaussin
ssing atau d
didalam par
Bearing
Shaft
Gear
Frame / ho
Coupling
Dll.
tisasi dapat
an oleh ka
idak sempu
erius pada
rbine blade,
magnet ya
discharge,
tisasi pada
asan menjad
bakan kerus
C:\SS
SiswJanOct
surement
pat diukur d
uss”.
er
er
ng
demagnetiz
rt2 mesin ya
using
t terjadi ka
arena sisitm
urna, residu
benda yan
, dll.
ng terjadi p
dan dapat
a bearing
di kondukto
sakan pada
SIS_File\Sis SEMSEMINAR\Printiwanto 10, 2009 2011
dengan me
ation adala
ang seharus
arena berba
m grounding
al voltage le
ng terpasan
pada part p
menimbulk
akan meny
or dan dialir
a part2 tsb k
Page (s) : 2MINAR\MATERng_Doc\Tot_Ma
Email: sis_cBlog: www.sMobile: +62
nggunakan
h suatu me
snya tidak d
agai hal se
g pada sha
ebih dari 1
ng pada sh
art tersebut
kan spark.
yebabkan
ri listrik, dan
karena adan
2 of 14 RI aint\POWERGEcahya@yahoosispowergene
2 81311 42227
D
n alat yang
ana
etode untuk
dialiri listrik
eperti yang
aft yang no
volt di dala
aft, seperti
t akan men
kerusakan
n magnetis
nya electric
ENERATION\DEo.com, siscahyeration.blogspo70
DemagnetizSteam T
disebut de
alog gauss m
menghilan
ayau meng
sudah diu
ormalnya di
m shaft aka
, bearing, g
nyebabkan
permukaa
asi pada tu
discharge.
EGAUSSING\[email protected]
Prozing on GE Turbine an
engan ‘gaus
meter
gkan meda
gandung ma
ulas diatas,
isebut deng
an menyeba
gear, coupl
kerusakan
an bearing
urbine blad
EGAUSSING.dgmail.com
oject ExpeFrame 9,
nd Rotor Ge
ssmeter” da
an magnet y
agnet, sepe
juga dapa
gan “ground
akan perso
ling, fan bla
karena ada
akibat sis
dan gear a
ocx
erience180 MW enerator
alam
yang
rti:
at di
ding
alan
ade,
anya
sitim
akan
Page (s) : 3 of 14
File documents C:\SIS_File\Sis SEMINAR\MATERI SEMINAR\Printing_Doc\Tot_Maint\POWERGENERATION\DEGAUSSING\DEGAUSSING.docx
Doc. Issued by Siswanto Email: [email protected], [email protected] Dtd. Doc issue Jan 10, 2009 Blog: www.sispowergeneration.blogspot.com Edited / Rev Oct 2011 Mobile: +62 81311 422270
Project ExperienceDemagnetizing on GE Frame 9, 180 MW
Steam Turbine and Rotor Generator
Berikut adalah batasan / standard magnetisasi yang masih di kategorikan aman:
Maximum Allowable Residual Magnetic Field Levels (As Measured in Open Air)
2 gauss: Bearing components, including pads and retainers, journals, thrust
disc, seals, gears and coupling teeth.
4 gauss: Bearing housings.
6 gauss: Mid-shaft and wheel areas, diaphragms, etc.
10 gauss: Components remote from minimum clearance areas, such as
casings, pipings, etc.
Ref : Paul I. Nippes, P.E., President Magnetic Products and Services, Inc.
D.1. Degaussing Techniques
Pada umumnya Degaussing dapat dilakukan dengan dua cara, yaitu dengan menggunakan
magnetic yoke dan “ampere turn de-magnetism’.
Untuk small part dan residual magnet yang kecil dapat digunakan “magnetic yoke”, tetapi untuk part
part yang besar dengan kandungan residual magnetic yang besar, tidak mungkin dilakukan dengan
menggunakan magnetic yoke. Untuk ampere-turn de-magnetism ada yang menggunakan auto
polarity dan manual polarity.
Dari pengalaman saya pribadi didalam menghilangkan magnetisasi di dalam Turbine dan Rotor
Generator berikut perlengkapannya, manual polarity degaussing dan magnetic yoke tidak berhasil
kami lakukan, dan magnetic field berhasil kami hilangkan dengan menggunakan “auto degaussing”
instruments.
Bentuk magnetic pada benda yang ter induksi selalu akan membentuk kutub utara dan selatan,
berikut adalah ilustrasi pembentukan medan magnet di suatu benda.
Page (s) : 4 of 14
File documents C:\SIS_File\Sis SEMINAR\MATERI SEMINAR\Printing_Doc\Tot_Maint\POWERGENERATION\DEGAUSSING\DEGAUSSING.docx
Doc. Issued by Siswanto Email: [email protected], [email protected] Dtd. Doc issue Jan 10, 2009 Blog: www.sispowergeneration.blogspot.com Edited / Rev Oct 2011 Mobile: +62 81311 422270
Project ExperienceDemagnetizing on GE Frame 9, 180 MW
Steam Turbine and Rotor Generator
Degaussing pada benda2 stationer ( tidak berputar) akan jauh lebih mudah dibandingkan pada
benda benda berputar, karena pada benda berputar ada interaksi medan magnet pada air gap
sedang pada benda tidak berputar tidak ada phenomena medan magnet pada air gap.
D.1.1. Metode demagnetisasi dengan magnetic yoke.
Magnetik yoke adalah suatu pembangkit magnetic permanent, digunakan untuk menginduksikan
medan magnet kedalam suatu benda yang mengandung medan magnet, yaitu dengan
menginduksikan medan magnet positip (+) ke dalam benda / bagian yang mengandung magnit
negative ( - ), dengan demikain diharapkan medan magnet yang tersisa didalam benda tsb akan
menjadi nol karen di netralisasi dengan polaritas yang berlawanan.
Kelemahan dari alat ini adalah, medan magnit yang diinduksikan tidak dapat diatur besarannya,
karena sifatnya statis. Sehingga kemungkinana besaran medan magnet yang di induksikan untuk
menetralisir muatan medan magnet akan menjadi kebesaran ataupun terlalu kecil, efeknya jika
medan magnet yang di induksikan terlalu besar, maka muatan sisa tidak akan hilang namun
berganti polaritas.
Selain itu arah polaritas magnetic yoke tidak mungkin bisa diarahkan secara tepat dengan arah
atau polaritas magnetic yang ada di dalam benda yang akan di netralisir.
Pada prinsipnya cara melakukan demagnetisasi adalah menginduksikan magnetic kedalam benda
yang mengandung magnetic dengan besaran yang sama tetapi dengan arah atau polaritas yang
berbeda:
Medan magnet di sekitar bidang solenoid
Medan magnet di sekitar bidang datar
Medan magnet di sekitar kawat lurus
File doc
Doc. IssDtd. DoEdited /
Misal,
mengan
tersebu
sebesa
Ilustras
Misal:
1.
2.
3.
4.
Maka c
sesuai
berlawa
Hal ini
yoke, k
penemp
Misal:
Magnet
ditempa
second
cukup 0
magnet
+
cuments
sued by c issue Rev
didalam s
ndung mag
ut netral (be
r 20 gauss
i :
Rapat flux
Rapat flux d
Rapat flux d
Rapat flux d
cara demag
dengan be
anan denga
sangat sul
karena besa
patan polar
tisasi perm
atkan yoke
, padahal p
0.5 second
tic sebesar
+
C:\SS
SiswJanOct
shaft atau
nit sebesar
ebas dari m
dengan pol
pada permu
di permuka
di permuka
di permuka
gnetisasinya
esaran kand
an yang ada
lit dan bah
aran induks
itas dan lam
ukaan pada
sebesar 2
permukaan
d, maka bid
20 gauss d
2
10
SIS_File\Sis SEMSEMINAR\Printiwanto 10, 2009 2011
gear atau
r 20 gauss
muatan mag
laritas nega
ukaan coup
an / layer k
an / layer k
an / layer k
a adalah, de
dungan ma
a.
hkan tidak a
si magnetic
ma penemp
a polaritas
0 gauss de
tsb akan ne
dang tsb tid
engan pola
-
20
15
Page (s) : 5MINAR\MATERng_Doc\Tot_Ma
Email: sis_cBlog: www.sMobile: +62
u coupling
dengan po
gnetic) , ma
atip (-).
Coupli
pling adalah
edua adala
e tiga adala
e empat < 1
engan mem
agntetic di
akan mung
c tidak mun
atan nya tid
positip ( +
engan pola
etral dengan
dak akan m
aritas yang t
5 of 14 RI aint\POWERGEcahya@yahoosispowergene
2 81311 42227
D
atau bea
olaritas pos
aka pada b
ng GE Gen
20 gauss
ah 15 gauss
ah 10 gauss
10 gauss
mberikan ind
setiap laye
gkin dilakuk
gkin di atu
dak mungki
+ ) adalah
aritas negat
n muatan 2
menjadi ne
terbalik dari
ENERATION\DEo.com, siscahyeration.blogspo70
DemagnetizSteam T
aring atau
itip (+), ma
enda tsb h
nerator 185
s
s
duksi magn
er dan haru
kan dengan
r sesuai de
n bisa diatu
20 gauss,
tip ( - ), lam
20 gauss po
tral, tetapi
i sebelumny
EGAUSSING\[email protected]
Prozing on GE Turbine an
apapun b
ka untuk m
arus di ind
MW
netic pada s
us memiliki
n menggun
engan kebu
ur secara m
lalu pada
ma penemp
olaritas nega
akan kemb
ya yaitu me
20
15
10
<10
EGAUSSING.dgmail.com
oject ExpeFrame 9,
nd Rotor Ge
bendanya,
membuat be
uksikan ma
setiap layer
polaritas y
akan magn
utuhan, bah
anual.
permukaan
patan adala
atip ( - ), ha
bali bermua
enjadi negat
ocx
erience180 MW enerator
jika
enda
agnit
r tsb
yang
netic
hkan
tsb
ah 1
anya
atan
tip.
Page (s) : 6 of 14
File documents C:\SIS_File\Sis SEMINAR\MATERI SEMINAR\Printing_Doc\Tot_Maint\POWERGENERATION\DEGAUSSING\DEGAUSSING.docx
Doc. Issued by Siswanto Email: [email protected], [email protected] Dtd. Doc issue Jan 10, 2009 Blog: www.sispowergeneration.blogspot.com Edited / Rev Oct 2011 Mobile: +62 81311 422270
Project ExperienceDemagnetizing on GE Frame 9, 180 MW
Steam Turbine and Rotor Generator
Misal didalam suatu benda yang terinduksi magnet memiliki 2 kutub U-S, dengan Rapat flux sebesar 20 gauss, seperti ilustrasi berikut: Ilusatrasi sebelum degaussing Setelah degaussing dng metode yg salah
Cara degaussing adalah menginduksikan magnetic sesuai Rapat flux dengan polaritas terbalik.
Dengan lama / waktu yang digunakan untuk induksi sesuai dengan charging time pada benda tsb.
Jika charging time, polarity dan magnitude dari induksi magnetic tidak tepat maka akan terbentuk
medan magnetic baru dengan polaritas yang berlawanan dengan sebelumnya sedang Rapat flux
tergantung dari dari charging time dan besaran induksi yang digunakan.
Degaussing dengan magnetic yoke.
U
S
U S
U
U S
S
‐20
+20
S
U
S U
S
S U
U
Page (s) : 7 of 14
File documents C:\SIS_File\Sis SEMINAR\MATERI SEMINAR\Printing_Doc\Tot_Maint\POWERGENERATION\DEGAUSSING\DEGAUSSING.docx
Doc. Issued by Siswanto Email: [email protected], [email protected] Dtd. Doc issue Jan 10, 2009 Blog: www.sispowergeneration.blogspot.com Edited / Rev Oct 2011 Mobile: +62 81311 422270
Project ExperienceDemagnetizing on GE Frame 9, 180 MW
Steam Turbine and Rotor Generator
D.1.2. Metode Degaussing / demagnetisasi dengan “auto degauss”
Auto degauss adalah suatu alat degaussing atau demagnetisasi dengan mengaplikasikan ‘ampere
turn’ dengan auto setting polarity.yaitu dengan memberikan induksi magnetic dengan
menggunakan induksi arus yang besarnya disesuaikan dengan Rapat flux yang ada atau di set
secara bertahap.
Besar induksi magnit yang ada dan arah atau polaritasnya di ukur lalu di plot, sehingga pola
magnatic yang terjadi akan dapat diketahui dengan baik, sehingga memudahkan untuk melakukan
seting besar arus yang akan di induksikan demikian juga pola polaritasnya, sedangkan charging
time yang diperlukan untuk memberikan induksi magnetic, instrument akan pengukuran secara
automatis.
Ilustrasi:
Pengukuran residual magnetic dan polaritas magnetic di coupling generator.
Besarnya ampere-turn yang akan di induksikan untuk mendapatkan “gauss” yang dikehendaki yang
akan digunakan untuk menetralisir muatan magnit yang ada dilakukan secara bertahap, yaitu
dengan menghitung nilai rata2 Rapat flux yang terbentuk, lalu di induksikan arus sebesar Rapat flux
rata2, lalu di ukur kembali residualnya, dan dilakukan degaussing ulang sesuai dengan residualnya.
‐15
+25
+27
+20
+13
+15
+17
‐24 ‐16
‐10
‐14
‐20
‐20
+12 +20
+22
+15
+16
+14 ‐22
‐16
‐20
‐12
‐14
Page (s) : 8 of 14
File documents C:\SIS_File\Sis SEMINAR\MATERI SEMINAR\Printing_Doc\Tot_Maint\POWERGENERATION\DEGAUSSING\DEGAUSSING.docx
Doc. Issued by Siswanto Email: [email protected], [email protected] Dtd. Doc issue Jan 10, 2009 Blog: www.sispowergeneration.blogspot.com Edited / Rev Oct 2011 Mobile: +62 81311 422270
Project ExperienceDemagnetizing on GE Frame 9, 180 MW
Steam Turbine and Rotor Generator
Besarnya Ampere turn yang diperlukan:
Ampere – turn adalah besaran arus yang akan dialirkan untuk menginduksikan dikalikan dengan
jumlah belitan kabel yang akan dialiri arus.
Jadi Ampere-Turn = Arus x Jumlah Lilitan = I x N
Misal, lihat gambar diatas:
Rapat flux rata-rata adalah : (+) 18 gauss dan (-) 17 gauss
Diameter coupling adalah: 77.5 cm atau 3.05 inch
Instrument akan di setting pada nilai terendah yaitu 17 gauss.
B (Flux density) = (0.49 x NI) / D
0.49 adalah permeability media ( coupling)
NI = (17 x 3.05) / 0.49 ≈ 106 Ampere Turn
Jika Jumlah kabel yang akan dililitkan pada coupling tsb adalah = 6 Lilitan, maka besar arus yang
harus di iinduksikan adalah sebesar:
I (Ampere) = 106 ampere-turn / 6 turn ≈ 21 Ampere
Pada tahap ini instrument akan di
set pada 21 ampere dengan
jumlah lilitan 6 , dan untuk
selanjutnya instrument akan di
set dengan arus yang lebih kecil
sesuai dengan rapat flux sisa
yang ada setelah di induksikan
arus sebesar 21 ampere 6 lilitan
atau 106 ampere turn. Sampai
didapat residual rapat flux
dibawah batas ambang yang di
izinkan, (lihat table batasan max
threshold yang di izinkan)
Auto degaussing max capacity 15000 ampere turn.
Page (s) : 9 of 14
File documents C:\SIS_File\Sis SEMINAR\MATERI SEMINAR\Printing_Doc\Tot_Maint\POWERGENERATION\DEGAUSSING\DEGAUSSING.docx
Doc. Issued by Siswanto Email: [email protected], [email protected] Dtd. Doc issue Jan 10, 2009 Blog: www.sispowergeneration.blogspot.com Edited / Rev Oct 2011 Mobile: +62 81311 422270
Project ExperienceDemagnetizing on GE Frame 9, 180 MW
Steam Turbine and Rotor Generator
D.2. Figure degaussing pada part turbine dan generator (ref project Rewinding dan
degaussing GE Turbine + Generator 185 MW.
D.2.1. Pengukuran Rapat flux
File doc
Doc. IssDtd. DoEdited /
D.2.2.
cuments
sued by c issue Rev
Shaft Cur
C:\SS
SiswJanOct
rrent Elem
SIS_File\Sis SEMSEMINAR\Printiwanto 10, 2009 2011
mentary Dia
Page (s) : 1MINAR\MATERng_Doc\Tot_Ma
Email: sis_cBlog: www.sMobile: +62
agram
10 of 14 RI aint\POWERGEcahya@yahoosispowergene
2 81311 42227
D
ENERATION\DEo.com, siscahyeration.blogspo70
DemagnetizSteam T
EGAUSSING\[email protected]
Prozing on GE Turbine an
EGAUSSING.dgmail.com
oject ExpeFrame 9,
nd Rotor Ge
ocx
erience180 MW enerator
File doc
Doc. IssDtd. DoEdited /
D.2.3.
cuments
sued by c issue Rev
Bearing In
C:\SS
SiswJanOct
nsulation
SIS_File\Sis SEMSEMINAR\Printiwanto 10, 2009 2011
“OflOE
Page (s) : 1MINAR\MATERng_Doc\Tot_Ma
Email: sis_cBlog: www.sMobile: +62
One methodow of shaft
Origin and PElectric, 192
11 of 14 RI aint\POWERGEcahya@yahoosispowergene
2 81311 42227
D
Path oTurn
d of insulatit currents”inPrevention”b27
ENERATION\DEo.com, siscahyeration.blogspo70
DemagnetizSteam T
of flux and c
ing bracket-n article “Beby C. T. Pea
EGAUSSING\[email protected]
Prozing on GE Turbine an
currents due
-type macharing Currearce, of We
EGAUSSING.dgmail.com
oject ExpeFrame 9,
nd Rotor Ge
e to Armatu
ine to preveents ---Theirestinghouse
ocx
erience180 MW enerator
ure
ent r e
File doc
Doc. IssDtd. DoEdited /
ModernAgainstPrevent
cuments
sued by c issue Rev
n open metht Stray Electative Maint
C:\SS
SiswJanOct
hod to insulactrical Curretenance Te
SIS_File\Sis SEMSEMINAR\Printiwanto 10, 2009 2011
ate pedestaents”by Michchnology N
Page (s) : 1MINAR\MATERng_Doc\Tot_Ma
Email: sis_cBlog: www.sMobile: +62
al bearingshael M. Cali
National Con
12 of 14 RI aint\POWERGEcahya@yahoosispowergene
2 81311 42227
D
1. He2. W3. In4. In5. En6. Be
Modern mmachinesShaft/EarCurrents”Field Serv04/1991
from articleistrat, Paul nference -19
ENERATION\DEo.com, siscahyeration.blogspo70
DemagnetizSteam T
exagon-heaWasher
sulation dissulating tubnd shield earing hous
method for is in article “Srth Voltages”Article “AR vices and W
e “InsulatingI. Nippes an997.
EGAUSSING\[email protected]
Prozing on GE Turbine an
ad screw
sc be
sing
nsulating brShaft Voltags –Bearing 170-220”by
Workshop O
g Rotating Mnd Ned Zem
EGAUSSING.dgmail.com
oject ExpeFrame 9,
nd Rotor Ge
racket type ges –
y Siemens Operations
Machinery man,
ocx
erience180 MW enerator
File doc
Doc. IssDtd. DoEdited /
ModernAgainstPrevent Four dAgainstPrevent
cuments
sued by c issue Rev
n hidden mt Stray Eletative Maint
ifferent met Stray Eletative Maint
C:\SS
SiswJanOct
ethod to inectrical Cutenance Te
ethods to inectrical Cutenance Te
SIS_File\Sis SEMSEMINAR\Printiwanto 10, 2009 2011
nsulate pedrrents”by Mchnology N
nsulate sharrents”by Mchnology N
Page (s) : 1MINAR\MATERng_Doc\Tot_Ma
Email: sis_cBlog: www.sMobile: +62
estal beariMichael M.
National Con
aft couplingMichael M.
National Con
13 of 14 RI aint\POWERGEcahya@yahoosispowergene
2 81311 42227
D
ngs from a. Calistrat, nference -19
gs from ar. Calistrat, nference -19
ENERATION\DEo.com, siscahyeration.blogspo70
DemagnetizSteam T
article “InsuPaul I. N
997.
rticle “InsulaPaul I. N
997.
EGAUSSING\[email protected]
Prozing on GE Turbine an
lating RotaNippes and
ating RotatNippes and
EGAUSSING.dgmail.com
oject ExpeFrame 9,
nd Rotor Ge
ating Machind Ned Zem
ting Machind Ned Zem
ocx
erience180 MW enerator
nery man,
nery man,
Page (s) : 14 of 14
File documents C:\SIS_File\Sis SEMINAR\MATERI SEMINAR\Printing_Doc\Tot_Maint\POWERGENERATION\DEGAUSSING\DEGAUSSING.docx
Doc. Issued by Siswanto Email: [email protected], [email protected] Dtd. Doc issue Jan 10, 2009 Blog: www.sispowergeneration.blogspot.com Edited / Rev Oct 2011 Mobile: +62 81311 422270
Project ExperienceDemagnetizing on GE Frame 9, 180 MW
Steam Turbine and Rotor Generator
E. References:
.1. Private Project for Rewinding and Degaussing on GE Turbine and Generator 180 MW,
JAKARTA, in collaborate with Rotor Pro South Africa, TUV Germany, Powertech Calidus
South Africa, VibraMax South Africa, West Ward Monitoring Systems (PTY Ltd) South
Africa.
2. Principles of Magnetism and Stray Currents in Rotating Machinery , I. Nippes, P.E.,
President Magnetic Products and Services, Inc
3. Bearing Insulation Testingin Rotating Machinery, by Paul I. Nippes, PEand Beth
GalanoMagnetic Products and Services, Inc.Holmdel, NJ 07733
4. MEASURING BEARING CURRENTS, PAVLIK MARINOV MOHAMMED MASUDUR
RAHMAN. Department of Energy and Environment. Division of Electric Power Engineering.
Chalmers University of Technology. Gothenburg, Sweden.
5. ELECTRICAL INSULATIONFOR ROTATING MACHINES. Design, Evaluation, Aging,
Testing, and Repair, GREG C. STONE, EDWARD A. BOULTER, IAN CULBERT, HUSSEIN
DHIRANI. IEEE Press Series on Power Engineering
6. Electrostatic Discharge on a Large Steam Turbine Generator, Sherief Mekawey | Bently
Nevada Machinery Diagnostics Engineer | GE Energy, United Arab Emirates
7. Turbogenerator Installation, Operation and Maintenance Manual.S Line. WEG
8. OPERATION AND MAINTENANCE OF LARGE TURBO-GENERATORS, Stamatios V.
Kartalopoulos, IEEE Press 445 Hoes Lane Piscataway, NJ 08854