Datacenter & Green IT
TCO Reduction and AgilityTCO Reduction and Agility
NEC Confidential 2
Recent Changes in the Enterprise Environment
TCO reduction, flexibility and agility are critical for companies in this turbulent environment
The enterprise business environment has been getting worse since the financial crisis
GlobalizationGlobalization
Internal ControlInternal Control
ComplianceCompliance
Sales/production decline*1
Shrinking Markets
Shrinking Markets
*1 Nikkei Business March issue 2009
Stock market crash*1
Worst since the bubble burst
Nikkei average and NYSE Dow
$/\
Nikkei Average
NYSE Dow
2009 Jan Feb Mar$6763
NEC Confidential 3
Diversified needs for IT systems spread cloud computing with speed.
IT systems now face new requirements.
FlexibilityFlexibility ReliabilityReliability ManageabilityManageability
NEC’s View on Requirements for IT systems
Environmental measuresEnvironmental measures++
The Ever Diverse Needs for IT Systems
Reduced Cost
Reduced Cost
NEC Confidential 4
Power Consumption of Data Centers
0
200 000
400 000
600 000
800 000
1 000 000
1 200 000
2006 2007 2008 2009 2010 2011 2012
517,000569,000
655,000
740,000836,000
945,000
1,068,000
The power consumption of enterprises and data centers in Japan will increase by 10% every year
The power consumption of enterprises and data centers in Japan will increase by 10% every year
Source: MIC Research Institute Ltd. : Survey on Datacenter Electricity Consumption and Green IT (FY2008 edition)Source: MIC Research Institute Ltd. : Survey on Datacenter Electricity Consumption and Green IT (FY2008 edition)
10tho. kWh
NEC Confidential 5
What is your focus to achieve low power IT? What is your focus to achieve low power IT?
11% 4%
37%
2%
29%
17%Green devicesGreen devices
Efficient useEfficient useTotal green operationTotal green operation
new power supplynew power supply
Not of concernNot of concern No ideaNo idea
Source: June 2008 JEITA Report on the trend of energy conscious IT and Green IT (250 responses)Source: June 2008 JEITA Report on the trend of energy conscious IT and Green IT (250 responses)
Use of green devices: ・ Servers, air conditioning, PCs and storage Efficient use ・ Balancing and integrating resources
Total green operation: ・ Reconsidering non-IT equipment as air conditioning and power supply
Use of green devices: ・ Servers, air conditioning, PCs and storage Efficient use ・ Balancing and integrating resources
Total green operation: ・ Reconsidering non-IT equipment as air conditioning and power supply
Optimization of the whole IT system ・ Balancing resources by virtualization ・ Focus not only on IT devices but total green operation including
air conditioning and power source etc.
Optimization of the whole IT system ・ Balancing resources by virtualization ・ Focus not only on IT devices but total green operation including
air conditioning and power source etc.
The Trend of Green IT –Actions–
NEC Confidential 6
Reduce energy consumption of
peripheral facilities
Reduce energy consumption of IT devices
Fan4%Power
supply 13%
Air conditioning44%
UPS Power distribution7%
CPU, memory, HDD 32%
Maximize energy efficiency to reduce power consumption
Minimize cooling by integrating measures with
IT devices
Power Consumption Breakdown of Data Centers
15%
85%
Well informedWell informed
50%
16%
23%
12%Assessment scheduledAssessment scheduled
Assessment to be scheduledAssessment to be scheduled
status quostatus quo
Don’t knowDon’t know
Don’t know wellDon’t know well
Do you know the how much power your IT devices and entire DC consumes?Do you know the how much power your IT devices and entire DC consumes?
Source: June 2008 JEITA Report on the trend of energy conscious IT and Green IT (252 responses)
The Initial Step of Green IT ~ Visualization ~
Future plans?
85%
15%
23%
16% 12%
50%
NEC Confidential 7
Under the REAL IT PLATFORM vision, NEC formulates activities to save power consumption in customer’ IT environment by delivering
energy saving technologies, products and services.
Energy Saving Platform Energy Saving Control Software
Server and storage products that employ advanced low power and energy conscious technologies
Software products that effectively control power saving functions of IT
devices
Service that achieves lower cost of operation by orchestrating IT equipments and facilities as
air conditioning and power distribution equipment
Energy Saving Facility Service
NEC promotes energy-savings in customers’ IT environment from three areas through the REAL IT COOL PROJECT.
NEC’s REAL IT COOL PROJECT
NEC Confidential 8
D Series NV Series HS series T Series
NEC’s Energy Saving Platforms
DataCenterLine DataStationLine
Drastic energy saving, space saving and weight reductionby high density mounting and cooling technologies based on
NEC’s mainframe and super computer development.Server Products : Cutting-edge energy-saving technology and reduce energy consumption
Storage products :Large capacity HDD and semi-conductor DISK, and reduction in energy consumption for holding unused data
NEC Confidential
Our Approach in 3 steps
▐ Analyze the existing Infrastructure
▐ Improve the infrastructure
▐ Manage and Monitor
NEC Confidential
Business model
Analyze the existing and define the objective
Building Infra IT
Process
Personnalized Audti processus
NEC Confidential 11
Design Construction
Design Construction MigrationMigration OperationOperation
Consolidation and summaryConsolidation and summary
Analyze information gathered by survey and build optimal method •Heat issues, power consumption, imbalance of resources, complex operation
The Green IT Cycle
Visualization(Survey)
Visualization(Survey)
【 Step2 】Survey servers and system environment with sensors and simulations
【 Step1 】Clarify issues and provide solutions based on on-site audit by specialists
Set goalsPlanningSet goalsPlanning
【 Short-term measures 】•Change layout of IT infrastructure •Rearrange under floor cables•Adjust air-conditioning of servers
【 Mid-term measures 】•Replace with green servers •Reduce servers •Transversal consolidation
Regular feedbacks and reviews utilizing 24 x 365 monitoring following implementation and migration
Analyze the present IT environment to clarify issues, then provide and perform the solutions
NEC Confidential 12
Operation
Provide services as 24 x 365 monitoring, support for failure and energy-saving operation etc.
Plan / Build
Based on survey results, design and deploy facilities optimized for the customer’s environment
Energy-saving Operation support
Various services to achieve lower energy consumption and green operation for peripheral
facilities as air conditioners of machine rooms and data centers
【 Proposal 】Design proposal
Site survey
【 Proposal 】Design proposal
Site survey
【 Plan / Build 】
Facility designFacility
construction
【 Plan / Build 】
Facility designFacility
construction
【 Survey 】Environmental
survey
【 Survey 】Environmental
survey
【 Operation】
MonitoringImprovements
【 Operation】
MonitoringImprovements
Thermal simulation at all stagesThermal simulation at all stages
Survey
Examine customer’s existing facility, implement environmental survey and thermal simulation.
Thermal simulation
Environmental survey
Energy Saving Facility ServiceEnergy Saving Facility Service
Future ServiceFuture Service
NEC Confidential
Our Aproach in 3 steps
▐ Analyze the existing Infrastructure
▐ Improve the infrastructure
▐ Manage and Monitor
NEC Confidential
VPCC
Oracle Database11g
SQLServer2008
Database ServerDatabase Server
AP/Web ServerAP/Web ServerClientsClients
BackupBackup ArchivageArchivage
NEC Confidential
Datacenter in the Rack
Virtualization
Automatisation
Infrastructure
ESX 4.0ESX 4.0
V.5V.5
NEC Confidential
Green Data Center
CASESTUDY
▐ Academic Center for Computing and Media Studies, Kyoto University
Customer needs :• Rationalisation of the IT
• Reduction of environmental impact
• TCO reduction through flexible distribution of server resources
• Full Secure service 24/365
Solution : • Virtualization
• SigmaSystemCenter
• Eco Center
• Storage D3
NEC Confidential
Green Data CenterCASE
STUDY
Customer gains : • Environment impact reduction
• Energy cost saving 55%
• One room for all the departments
• Provisioning on demand
• Flexible and dynamic resources allocation through sigma system center and full virtualization
• All data’s secured on san storage
▐ Academic Center for Computing and Media Studies, Kyoto University
NEC Confidential
Kyoto University Green infrastructureCASE
STUDY
NEC Confidential
ECO CENTER
Electrical Power Saving 50%• Efficient power supply• Efficient airflow• Platform management workload optimization sw
Feature 1
Feature 2
Feature 3
50% Weight reduction and Space saving•80 servers in one bay• Low weight design / aluminium 650kg
Modular investment and easy management• Standard design• Compatible with any 19” Bay
The Optimized Energy saving and virtualization platform
Powerful.Intelligent
.
NEC Confidential© NEC Corporation 200820
‘80 PLUS Gold’ certified highly efficient PSU
ECO CENTER
20%
40%
60%
80%
100%
Effi
cienc
yPOWER
Limited efficiency
92%92%92%92%
STANDARD SERVER
Low power components and fluid air flow
NEC Confidential 21
Monitoring of load / running condition
The optimize engine buildsbest reallocation plan Move the VMs
Virtualization SWVirtualization SW
Virtualization SWVirtualization SW
Virtualization SWVirtualization SW
Virtualization SWVirtualization SW・ High load・ Hot spot
・ Optimized load・ No Hot spot
TASK A TASK B TASK C
TASK D TASK E
VM VM VM
VM VM
VM VM VM
VM VM
TASK A TASK D
TASK ETASK B
TASK C
Virtualization + Optimized Platform Operation = Energy Saving
Virtual machines survey and workload balancing
NEC Confidential 22
Monitoring of load / running condition
Consolidation of virtual machines in the range of
effective load level
Shut down inactive servers
Appropriate Load Level
on on on on on
CPU usage rate
on on on offoffTurnOff
Appropriate Load Level
Virtualization + Optimized Platform Operation = Energy Saving
Servers survey and workload balancing
NEC Confidential 23
Number of racks: 2Weight: approx. 1660kg(16kg x 80 units + 191kg x 2 racks)
Number of racks: 1Weight: 655kg
Highly-efficient power supply
Light weight realized by optimized placement of components and
aluminum material
220mm
85mm650mm
Space Savings and Weight Reduction
Server#2
Server#1
Former1U rack servers
42Urack
Space savings by two servers in one module sharing components as power supply unit
Two servers are modularized
weight9.5 kg
Comparison of 80 servers
Space: 50% less ----- Weight: 60% less
ECO CENTER
40 modules per rack
NEC Confidential
server×40storage×2switch×8
Under 500 kg/m 2 floor load
storage
storage
management switch
switchswitchswitch
switchswitchswitch
management switch
40 servers
ECO CENTER
server×20storage×1switch×4 (per 1 rack)
Under 500 kg/m 2 floor load
management switch
switch
server
storage
20 servers
serverserver
serverserver
・・・
switchswitch
Space lost due to weight limit
Standard solution based on 1U racks
Under 500 kg/m 2 floor load
management switch
switch
server
storage
serverserver
serverserver
・・・
switchswitch
Datacenter in the Rack : All in One Bay
floor load= Whole weight÷(rack/cabinet bottom area + maintenance area)
NEC Confidential
Old DC • 6.5M bops
• 7 rooms
• 9 racks
• 160 servers
• 62 kWh
• 543MW.year
• 45.5T-CO2
Kyoto Data Center Refresh
Performance increase
X6
AnnualEnergy Costs
50%Reduction2
Floor Space
85%Reduction1
The Bottom Line Benefits for IT
Eco center• 38M bops
• 1 room
• 2 racks
• 128 servers
• 30 kW
• 262Mw.year
• 22T-CO2
Express5800/Storage D-series
Reduce the Foot print and the Energy consumption of massive backup
NEC Confidential
Direct Connection to server / DAS
SAN storage arrays
Scalability
Per
form
ance
s /
Ava
ilab
ilit
y
D8-30
D1-10
D3-10
ST1230
Centralized storage
management
NEC Storage
NEC Storage ManagerClient
NEC Storage ManagerServer
•Storage Resource Management - iStorage Manager
•Point in Time Snapshot - SynamicSnapVolume
•Intra Bay Replication - DynamicDataReplication
•Inter Bay Replication - Remote Data Replication
Overview of the NEC storage range 31 % Energy saving
NEC Confidential
NEC Storage D Series Scalable Models
Pe
rform
an
ce
/Fe
atu
re
Pe
rform
an
ce
/Fe
atu
re
Expandability Expandability
Petabyte class scalable storage solution with flexible expansion
High cost performance storage solution for small-mid size systems
NEC Storage D3
NEC Storage D8
Entry model
Low-end model
Scalable model1 node1 node
2 nodes2 nodes
4 nodes4 nodes
Online Scale up
NEC Storage D1
NEC Confidential
Economy-MAID Technology-Phoenix Technology
Performance- Up to 64 FC 4Gbps ports- Up to 128GB cache- 15K RPM SAS
Availability- RAID-6, Triple Mirror- Dual redundant cache- Path failover, load balancing
Manageability- Virtualization- Enterprise software suite
•Replication•Snapshots
Scalability- 5,260 to 1 scale factor- 216GB to 1,152,000GB
Flexibility- Modular expansion- Non-disruptive- Dynamic Pools
Data Value
Capacity
ComplexityBudgets
D-Series Enterprise Modular Storage
Express5800/i120Ra-1E
Reduce the Hosting Farms Energy consumption
NEC Confidential
Lower power-consuming components and distant energy contrôl
Low thermal dissipation
Mount into short Rack
Outstanding maintainability improves ease of use
Fonctions PrincipalesFonctions Principales
EXPRESSSCOPE Engine 2
2 x CPU XeonQuad-Core/ Dual-Core
Up to 48GB memory
SATA hot plug 4 x 2TB 3.5”
8 x 500GB 2.5”
SAS hot plug 8 x 300GB 2.5”
i120Ra-1E: Performance +65% Vs previous model
•CPU 80W with power contrôl
•Low power consuming chipset
and memory
•Automatic Fan speed
optimization
•Power supply 80+ silver
•Power consumption contrôl
Linux
Powerful.Intelligent
.
NEC Confidential
Pull Out Tab Front Ports
Tool free guide rails
Push Attach
Shorter depth, lighter weight
72 CM60 CM
Max.21kg Max. 14kgi120Rg-1
i120Ra-e1
VGA USB 2.0
NEC Confidential
Quick and Easy Service and Support : TCO saving
leds
NEC Confidential
More servers per rack (32A – 6KVa)
R120a-1 (Classic/1U)2x Xeon E5520
2x 1GB Memory2x 160GB HDD(3.5”)
with HW RAID (Ruchbah)
i120Ra-1E2x Xeon L5520
2x 1GB Memory2x 500GB HDD(3.5”)
with HW RAID (Ruchbah)
315W 228W
i120Ra-e12x Xeon L5410 (2.33GHz)
4GB memory2x 80GB HDD
(RAID1 configuration)
239W
19 Servers 25 Servers 26 Servers
NEC Confidential
AnnualCO-2
92%Reduction2
2004 Servers • 6.5M bops
• 9 racks
• 160 servers
• 62 kWh
• 543Mw.year
• 45.5T-CO2.year
The perfect model to replace old park
AnnualEnergy Costs
92%Reduction2
Floor Space
88%Reduction1
iModel• 6.5M bops
• 1 Racks
• 22 servers
• 5 kWh
• 43.8MW.year
• 3.6T Co2.year
NEC Confidential
Our Aproach in 3 steps
▐ Analyze the existing Infrastructure
▐ Improve the infrastructure
▐ Manage and Monitor
NEC Confidential 36
MCOperations
Advanced autonomous operationmanageme
nt
Masterscope effectively controls energy-saving technology of the hardware in consistency with workload to realize low-power
operation of total system
1. Control power
Pow
er consumption
Power limit
2. Shut-down inactive servers
Appropriate workload
3. Eliminate hot spots
Air C
onditionerComprehensively visualize
workload, power, and temperature of servers
Command optimal low power operation under the
datacenter policy
Monitor and control the IT infrastructure
Policy / Knowledge Scenario
Virtualization TechnologyVirtualization Technology
Energy Saving Control Software with VirtualizationEnergy Saving Control Software with Virtualization
NEC Confidential
Visualization
Visualization
DecisionDecision
ImprovementImprovement
Entire Integration
Visualize
Decision
Improvement
Easy to visualize the system and its risk
Friendly GUI for various functionality
By autonomic operation,to improve it for
comfortable managementAutomatic resource
optimization with various senarios
Navigate appropriate decision Support with system
management knowledge
Simple VisualizationVisualization
Simple DecisionDecision
Simple ImprovementImprovement
Concept of MasterScope
NEC Confidential
Individual management for each system
Service
AP-log
Sys-logEvent-log
performance
Process
Takes TOO MUCH TIMEfor the system
operation
Daily management Know-how for the nonce
Only Ms. A knows about
what we should refer to…
I know Mr. B fixed this problem before, but no documents left!!
System administrator
Cannot notice the problem
Cannot access the systemWhat !?
System User
System administrator
Identifying the affects
12
6
3912
6
39
12
6
39
12
6
39
・ Hardware problem?・ Software problem? ・ Function problem?
I have to retrieve it soonWhat is wrong..?
Master Scope Operation Navigator
Uniform the management
・・・LOG
Pinpointing the
failure point by single display
monitor.
LOG
LOG
Early detection of failures
notification
Sharing Know-how
cause
solution
immediately identifying the affected area by categorizing business
operation messages
Business System
Business View
DB
AP server
monitor report
analyse
support
Base de donnée Base de donnée
Prevent failure events and supports the early detection, analysis and recovery
NEC Confidential
OperationsNavigator is simple by using one display to fix monitoring
Topology ViewMonitoring for each server
Business Viewmonitoring
for each business operationCategorize threshold values
into “Warning” and “Abnormal”.
Event Console
Same console can be fixed Visual monitoring
Monitoring status
Pinpoint display of failure view and simple operation
NEC Confidential
Systems Management
Energy Saving
SecurityAvailability
Computing Performance
►Automation : simplified routine tasks & processes. easy definition of policies
•OS / AP installation•Patch distribution•Backup/restore operation
►Dynamic Pools of Resources.►Automatic Load Balancing
►Shared Spare Servers►case of failure, automatic operation restoration►Detailed HW monitoring In
Provisioning Tool from SMB to Enterprise
►Optimize Servers load►Automatic switch off and switch on
NEC Confidential
Energy saving and performance management
ON ON ON ON ON
Appropriate workload 85%
ON ON ON OFF OFF
Appropriate workloadCPU utilization
Monitoring workload
Planning deployments
Optimizing workloads
NEC Confidential
transversal Integration : Investments Protected
© NEC Corporation 2005
VirtualServer
VirtualServer
VirtualServer
VirtualServer
VirtualServer
VirtualServer
XenMotion VMotion
vCentervCenterXen Center
ESX ServerESX Server
Vir
tual
Vir
tual
En
viro
nm
ent
En
viro
nm
ent
Vir
tual
Vir
tual
En
viro
nm
ent
En
viro
nm
ent
Psy
sic
alP
sysi
cal
En
viro
nm
ent
En
viro
nm
ent
Psy
sic
alP
sysi
cal
En
viro
nm
ent
En
viro
nm
ent
XenServerEE XenServerEE
XenServer vSphere
NEC Confidential 43
Server and storage products that employ
advanced low power and energy conscious
technologies Energy Saving Control Software
Software products that effectively control power
saving functions of IT devices
Service that achieves lower power by orchestrating IT
equipments and facilities as air conditioning and power distribution equipment
Energy Saving Facility Service
GREEN ITGREEN IT
NEC is devoted to support your IT environment go NEC is devoted to support your IT environment go GREEN through its expertise in technology and rich GREEN through its expertise in technology and rich
experience as an solution provider experience as an solution provider
NEC is devoted to support your IT environment go NEC is devoted to support your IT environment go GREEN through its expertise in technology and rich GREEN through its expertise in technology and rich
experience as an solution provider experience as an solution provider
Energy Saving Platform
NEC Confidential
OFFICIAL LABELS
NEC Confidential