1 cm vacuum insulation 5-8 cm standard insulation€¦ · Single element test 10, 15, 20, 25, 30,...
Transcript of 1 cm vacuum insulation 5-8 cm standard insulation€¦ · Single element test 10, 15, 20, 25, 30,...
VARIOTEC GmbH & Co. KG Werk 2
Moosweg 12
D-92318 Neumarkt i.d.OPf.
Tel.: +49 9181 6946-10 | Fax: 6946-71
[email protected] | www.variotec.de
Balcony, terrace,
flat roof insulation
F insulation -açade
/B2 faB1 Fire protection çade with approval
Dormer and bay insulation
Insulation for venetian
blinds/roller shutter boxes
Window soffit
Door or lintel encasing
Surface laying of
unlaminated panels
Internal floor insulation Post and beam façade
Ceiling/Internal wall insulation
VARIOTEC panels safety, quality, variety and serviceð
PRODUCT OVERVIEW
for exterior and interior insulation
Up date: November 2018
VARIOTECVacuum insulation
1 cm vacuum insulation 5-8 cm standard insulation!
The Lambda value of 0,007 W/(mK)* and the U -value of up to 0,14 W/(m²K) speak for themselves.P
www.variotec.de start productsð ð
VIP/QASA vacuum insulationð
*as rated value - initial value 0,0043 W/(mK)
The vacuum insulation elements from VARIOTEC constitute an elegant solution to any insulation
problem. On areas where the „conventional“ insulation material is too thick convinces the
vacuum insulation with .lower building height
The sandwich construction works with an insulation core of vacuum insulation panels (VIP)
consisting of evacuated pyrogenic silica, an enclosed mat of fibres and a multilayer high barrier
film. The cover layers are adapted to the external and internal application areas.
Because of this composition exists nearly no heat conduction. Thus the extremely thin elements
achieve very good insulation values.
A andVIP insulation of 5 cm achieves an U-value of 0,14 W/(m²K) equates to 25 cm of a
conventional insulating material.
General information of VIP/QASA insulation
page 2
VARIOTECVacuum insulation
Ge
ne
ral
tech
nic
al
ap
pro
va
l
Eu
rop
ea
n t
ech
nic
al
ap
pro
va
lE
TA
-13
/0
49
3
16.11.2017 III 12-1.23.11-612/17
Z-23.11-1779 16. November 2017
16. November 2022
Variotec Sandwichelemente GmbH & Co. KG
Weißmarterstraße 3
92318 Neumarkt/Oberpfalz
Vakuum-Wärmedämmplatten aus Kieselsäure
"QASA-D" und "QASA-N"
Der oben genannte Zulassungsgegenstand wird hiermit allgemein bauaufsichtlich zugelassen.
Diese allgemeine bauaufsichtliche Zulassung umfasst zehn Seiten.
Approval from a VIP core thickness of 20 mm
| Moosweg 12 | D-92318 Neumarkt i.d.OPf. | Tel.: +49 9181 6946-10 | Fax: 6946-71 | [email protected] | www.variotec.deVARIOTEC GmbH & Co. KG Werk 2
Calculated values accord. to rated value 0,007 W/(mK)1
Technical approval number of the DIBt national, general technical approval (AbZ).Z-23.11-1779
The additional heat losses caused by thermal bridges in the edge area of the VIP panels are taken
into consideration.
* 10 mm : U = 0,70 W/(m²K)VIP core P
* 15 mm : U = 0,47 W/(m²K)VIP core P
20 mm : U = 0,35 W/(m²K)VIP core P
25 mm : U = 0,28 W/(m²K)VIP core P
30 mm : U = 0,23 W/(m²K)VIP core P
35 mm : U = 0,20 W/(m²K)VIP core P
40 mm : U = 0,18 W/(m²K)VIP core P
50 mm : U = 0,14 W/(m²K)VIP core P
* General technical approval from
a VIP core thickness of 20 mm1
Rated value 0,007 W/(m²K) - initial value 0,0043 W/(m²K)
Technical information of VIP/QASA insulation
U : ( total )! "#!core plus covering = installation thickness
| Moosweg 12 | D-92318 Neumarkt i.d.OPf. | Tel.: +49 9181 6946-10 | Fax: 6946-71 | [email protected] | www.variotec.deVARIOTEC GmbH & Co. KG Werk 2
page 3
VARIOTECVacuum insulation
VIP core thicknesses
Edges
Adjustable edges
Supporting core density
Supporting core material
Specific heat capacity
Fire behavior
Compressive stress
Internal pressure
Calculated pressure increase
Core tolerances
Single element test
10, 15, 20, 25, 30, 35, 40, 45, 50
All edges are protected with adhesive tape.
XPS/PUR insulation stripes to cut and fit the elements in the edge area,
width of the insulation stripes subject to agreement
190 - 220 kg/m³
Pyrogenic silica with supporting fibres and infrared opacifier
C = 1kJ /(kg K)approx.
Normally inflammable (building material class DIN 4102-B2,
flammable material class B1 deliverable with technical approval)
At 10% shortening: 10 %ό = 190 kPa
At the delivery of the panel < 7 mbar
Approx. 1 mbar / a
Thickness +1 / -2 mm, length sizes ± 2 mm
Each vacuum insulation element will be checked twice with a quality test
Lambda value 0,007 W/(mK) (as rated value) / 0,0063 W/(mK) acc. to European technical approval ETA-13/0493
Construction of a VIP element laminated on both sides
High-barrier film
Fleece cover
(dust protection for
the sealed seam)
Support core consisting of pyro-
generic silica with
neutral additives
Construction of a vacuum insulation panel: What is inside?
Unlaminated panel VT-VIP blank (uncoated)
with technical approval Z. 23.11.1779
| Moosweg 12 | D-92318 Neumarkt i.d.OPf. | Tel.: +49 9181 6946-10 | Fax: 6946-71 | [email protected] | www.variotec.deVARIOTEC GmbH & Co. KG Werk 2
page 4
VARIOTECVacuum insulation
covering above e. g.
GFK, rubber, XPS
VIP (vacuum insulation panel)
covering below e. g.
GFK, rubber, XPS
Cutting area with
PUR/XPS edge to adapt
compression tape for sealing
of the panel and wall joints
adhesive tape on the panel joint above – humidity-resistant,
open to diffusion and UV durable
Operational areas of the VACUUM INSULATION
Comparison of the insulation thickness of a VIP with conventional insulation
Low construction heights high insulation effectó
Conventional insulation
Vacuum insulation
| Moosweg 12 | D-92318 Neumarkt i.d.OPf. | Tel.: +49 9181 6946-10 | Fax: 6946-71 | [email protected] | www.variotec.deVARIOTEC GmbH & Co. KG Werk 2
page 5
VARIOTECVacuum insulation
Flat and steep
roof insulationDormer and
bay insulation
Wall and interior
ceilings insulation
Floor insulation
Façade
insulationInsulation for
venetian blinds/roller
shutter boxes
Floor heating /
Dry screed
SAFE & SPEED
stock programmeWindow reveal
B1 Fire
protection façade
Layout drawings with numeration free of charge
VARIOTEC
Wir empfehlen, aufgrund der bauphysikalischen Richtlinien, den Einsatz der Compribänder am
Wandanschluss sowie bei den Elementstößen. Außerdem sind die Fugen mit wasserabweisendem
Klebeband abzukleben! Des Weiteren verweisen wir auf unsere Verarbeitungsrichtlinien.
VT-I-B-GFK-XPS-5
für Nassestrich1,5 mm GFK
20 mm VIP
5 mm XPS
Kantenschutz:4-seitig reißfestes Klebeband
Flächen:Gesamt 13,04 qm (ohne Mindestberechnungsfläche)
VIP 12,83 qm
Schaumanteil 0,017
2 Rollen „Compriband Wandanschluss“ - Wandanschluss
2 Rollen „Compriband Elementstoß (innen Elemente)“ - innen Elemente
Musterverlegeplan
Verlegeplan 01 (1)COM: 000000gez. 00.00.2018 X. Sutor
1000 x 500 mm
Free layout drawing
with numbering!
Delivered panels are also
numbered, consequently
an easy laying is possible!
Low construction heights high insulation effectó
| Moosweg 12 | D-92318 Neumarkt i.d.OPf. | Tel.: +49 9181 6946-10 | Fax: 6946-71 | [email protected] | www.variotec.deVARIOTEC GmbH & Co. KG Werk 2
single-layer laying
2-layer laying
page 6
VARIOTECVacuum insulation
Exterior and interior insulation
External insulation
Flat roof insulation
VT-A-DA-2 R-GGR*Standard variant with
rubber granulate on both sides
3 mm R-rubber (rubber granulate)
Vacuum insulation / VIP-core
3 mm R-rubber (rubber granulate)
1,5 mm GFK (fiberglass reinforced plastic)
Vacuum insulation / VIP-core
3 mm R-rubber (rubber granulate)
VT-A-DA-GFK/GGRCombination robust step, resistant
surface, below compensation
of small unevenesses
VT-A-DA-2 GFKRobust, impact-resistant design
with protective layer GFK
1,5 mm GFK (fiberglass reinforced plastic)
Vacuum insulation / VIP-core
1,5 mm GFK (fiberglass reinforced plastic)
VT-A-DA-2 XPS*XPS (Styrodur) design for
compensating small unevenesses
VT-A-Trittschall (impact sound)
Thermal insulation with
impact sound reduction
1,5 mm GFK (fiberglass reinforced plastic)
Vacuum insulation / VIP-core
8/4 mm rubber type outside
VT-VIP blank (QASA-N)*Versatile refrigeration and
construction industry
e. g. flat roof, floor insulation
Unlaminated vacuum insulation
Product type Construction Panel images
Balcony, terrace and flat roof
5 mm XPS
Vacuum insulation / VIP-core
5 mm XPS
| Moosweg 12 | D-92318 Neumarkt i.d.OPf. | Tel.: +49 9181 6946-10 | Fax: 6946-71 | [email protected] | www.variotec.deVARIOTEC GmbH & Co. KG Werk 2
* Also available as ... when it has to go fast!SAFE & SPPED stock programme
Further can be found atinformation as well as our request and order form www.variotec.de
We are happy to respond to , with our designs,your individual wishes just call us.
VIP core thickness / vacuum insulation :Lambda-value = 0,007 W/(mK)
* : U = 0,70 W/(m²K)10 mm VIP core P
* : U = 0,47 W/(m²K)15 mm VIP core P
: U = 0,35 W/(m²K)20 mm VIP core P
: U = 0,28 W/(m²K)25 mm VIP core P
a* General technical approval from VIP core thickness of 20 mm
30 mm VIP core: U = 0,23 W/(m²K)P
: U = 0,20 W/(m²K)35 mm VIP core P
: U = 0,18 W/(m²K)40 mm VIP core P
: U = 0,14 W/(m²K)50 mm VIP core P
Product system overview VACUUM INSULATION
page 7
VARIOTECVacuum insulation
Product type Construction Panel images
External insulation
insulationFaçade
VT-A-VHFInsulating system for
ventilated curtain façade
Fire protection B2 (VHF)
1,5 mm GFK (fiberglass reinforced plastic)
Vacuum insulation / VIP-core
5 mm XPS
15 mm hydro panel HD
Vacuum insulation / VIP-core
10 mm XPS
VT-A-HYDROVacuum insulation façade
with plaster base board fire
protection B2 incl. fastening system
VT-A-2-ALU/MAXPost and beam
Fa insulation, fillingçade
2/3 mm aluminum or Max Exterior
Vacuum insulation / VIP-core
2/3 mm aluminum or Max Exterior
VT-A-ROLLRoller shutters boxes and venetian blinds
VT-A-LAIBInsulation for window and door soffits
5 mm XPS (Styrodur)
Vacuum insulation / VIP-core
5 mm XPS (Styrodur)
VT-A-B1 (QASA Firetherm)Insulation system for requirements
Fire protection B1 (VHF)
System thickness 31-56 mm
Construction acc. to approval
3 mm A1 top coat
vacuum insulation / VIP-core25-50 mm
3 mm A1 top coat
1,5 mm GFK (fiberglass reinforced plastic)
Vacuum insulation / VIP-core
5 mm XPS
VT-A-GAUBDormer and bay insulation
without sight requirement
3 mm plywood*
Vacuum insulation / VIP-core
3 mm plywood**acc. to the manufacturer‘s specification as standard
Dormer and bay insulation
VT-A-DA-2 PP-Vlies (mat of fibres)
At minimal height on both
sides PP fleece (hydrophobic)
0,5 mm PP fleece grey
Vacuum insulation / VIP-core
0,5 mm PP fleece grey
Insulation for venetian blinds, roller shutter boxes and soffits
| Moosweg 12 | D-92318 Neumarkt i.d.OPf. | Tel.: +49 9181 6946-10 | Fax: 6946-71 | [email protected] | www.variotec.deVARIOTEC GmbH & Co. KG Werk 2
Further can be found atinformation as well as our request and order form www.variotec.de
We are happy to respond to , with our designs,your individual wishes just call us.
Product type Construction Panel images
Product type Construction Panel images
Product type Construction Panel images
Product type Construction Panel images
page 8
VARIOTECVacuum insulation
Product system overview VACUUM INSULATION
Internal insulation
Internal floor insulation
VT-I-B-GFK-XPS-10for dry screed and
floor heating system
1,5 mm GFK (fiberglass reinforced plastic)
Vacuum insulation / VIP-core
10 mm XPS (Styrodur)
5 mm XPS (Styrodur)
Vacuum insulation / VIP-core
5 mm XPS (Styrodur)
VT-I-B-2 XPS-5XPS (Styrodur) design to
compensate small unevenesses
VT-I-Trittschall (impact sound)
Thermal insulation and impact
sound reduction
1,5 mm GFK (fiberglass reinforced plastic)
Vacuum insulation / VIP-core
3 mm rubber type inside
VT-I-B-OSB (MFP)OSB/MFP Top and
bottom XPS (Styrodur)
VT-I-Wand/Decke
(wall/ceiling)Wall and ceiling insulation
without sight requirement
1,5 mm GFK (fiberglass reinforced plastic)
Vacuum insulation / VIP-core
5 mm XPS (Styrodur)
VT-I-B-GFK-XPS-5for wet and wet heating screed
1,5 mm GFK (fiberglass reinforced plastic)
Vacuum insulation / VIP-core
5 mm XPS (Styrodur)
10 / 22 mm MFP/OSB
Vacuum insulation / VIP-core
10 mm XPS (Styrodur)
| Moosweg 12 | D-92318 Neumarkt i.d.OPf. | Tel.: +49 9181 6946-10 | Fax: 6946-71 | [email protected] | www.variotec.deVARIOTEC GmbH & Co. KG Werk 2
Further can be found atinformation as well as our request and order form www.variotec.de
We are happy to respond to , with our designs,your individual wishes just call us.
Internal wall and ceiling insulation
Technical drawings (details) tender texts can be foundas well as in our download area
http://www.variotec.de/start/downloads/vip-qasa-vakuumdaemmung
VT-VIP-Füllung (filling)Fillings of all type
Plywood or other materials
Vacuum insulation / VIP-core
Plywood or other materials
Fillings
Product system overview VACUUM INSULATION
Product type Construction Panel images
page 9
VARIOTECVacuum insulation
Product type Construction Panel images
Product type Construction Panel images
Inquiry / Order forms: download at www.variotec.de
QASA/VIP Technology and processing
Ms. Häberl: +49 9181 6946-29
E-mail: [email protected]
QASA/VIP Inquiries and orders
Ms. Schmid: +49 9181 6946-10
E-mail: [email protected]
Find out more on our website www.variotec.de or call us:
VARIOTEC
Wir empfehlen, aufgrund der bauphysikalischen Richtlinien, den Einsatz der Compribänder am
Wandanschluss sowie bei den Elementstößen. Außerdem sind die Fugen mit wasserabweisendem
Klebeband abzukleben! Des Weiteren verweisen wir auf unsere Verarbeitungsrichtlinien.
VT-I-B-GFK-XPS-5
für Nassestrich1,5 mm GFK
20 mm VIP
5 mm XPS
Kantenschutz:4-seitig reißfestes Klebeband
Flächen:Gesamt 13,04 qm (ohne Mindestberechnungsfläche)
VIP 12,83 qm
Schaumanteil 0,017
2 Rollen „Compriband Wandanschluss“ - Wandanschluss
2 Rollen „Compriband Elementstoß (innen Elemente)“ - innen Elemente
Musterverlegeplan
Verlegeplan 01 (1)COM: 000000gez. 00.00.2018 X. Sutor
1000 x 500 mm
Supplied panels will also
be numbered, thus easy
installation possible!
Low construction heights high insulation effectó
A brief overview of the
main application areas:
ü Internal floor insulation
(also for underfloor heating)
ü Floor panels for impact sound
indoors / outdoors
ü Ceiling and internal wall insulation
ü Balcony, terrace and flat roof insulation
ü Dormer and bay insulation
ü Insulation for roller sutter boxes and
venetian blinds
ü Window and door soffits
ü B1 fire protection with approvalfaçade
ü Ventilated fa ade / insulationç çadeFa
ü Post and beam façade
ü Fillings of all type
ü Unlaminated VIP panels (versatile)
Inquiry / Order forms for vacuum panels1 cm vacuum insulation 5-8 cm standard insulation!
For individual panels e. g.
fillings / roller shutter and venetian blinds:
Please use forms !page 8-10
For areas after measurement:
Please use forms !page 1-7
VARIOTEC GmbH & Co. KG Werk 2
Moosweg 12
D-92318 Neumarkt i.d.OPf.
Tel.: +49 9181 6946-10 | Fax: 6946-71
[email protected] | www.variotec.de
Balcony, terrace,
flat roof insulation
Insulation - B1 Fire protection
façade with approval
Dormer and bay insulation
Insulation for venetian
blinds/roller shutter boxes
Window soffit
Door or lintel encasing
Surface laying of
unlaminated panels
Internal floor insulation Post and beam façade
Ceiling/Internal wall insulation
VARIOTEC Panels Safety, quality, variety and serviceð
PRODUCT OVERVIEW
for exterior and interior insulation
Stand: March 2018
VARIOTECvacuum insulation
1 cm vacuum insulation 5-8 cm Standard insulation!
The Lambda value of 0,007 W/(mK)* and the Up value of up to 0,14 W/(m²K) speak for themselves.
www.variotec.de start productsð ð
VIP/QASA vacuum insulation systemð
*as rated value - initial value 0,0043 W/(mK)
page 10
VARIOTECVacuum insulation
Gauben-Erkerdämmung Pfostenriegelfassade
Stand: März 2018
www.variotec.de start produkteð ð
VIP/QASA Vakuumdämmsystemð
Free of charge layout drawing
SAFE & SPEED...when it has to go fast!
...from one of the leading suppliers!
Up date: November 2018
Prefabricated VIP elements in
20 mm 30 mmand on stock
Stock programme vacuum insulation
VARIOTEC GmbH & Co. KG Werk 2
Moosweg 12
D-92318 Neumarkt i.d.OPf.
Tel.: +49 9181 6946-10 | Fax: 6946-71
[email protected] | www.variotec.de
Only in on your site!8 days
Safe & Speed VIP blank
(unlaminated)
Safe & Speed R-Gummi
(rubber)
Safe & Speed XPS
unlaminated vacuum insulation laminated with rubber granulate on both sides laminated with XPS on both sides
3 designs as available at short notice!standard sizes
for external and internal insulation
Lambda value 0,007 W/(mK) as rated value (initial value: 0,0043 W/(mK))
Operational areas amongst others as:
flat roof, balcony and terrace insulation, internal floor insulation, cooling industry and many more
Thickness comparison
www.variotec.de start productsð ð
ð VIP/QASA vacuum insulation system
VARIOTECVacuum insulation
Conventional insulation
Vacuum insulation
Technical approval Z.23.11.1779 from DIBt, fire protection B2* certified
(*Panel core/ Support core is not inflammable and is assigned to fire protection class A1)
Conventional insulation
Vacuum insulation
page 11
VARIOTECVacuum insulation
Information service: VACUUM INSULATIONVIP/QASA
Please send us the following documentation regarding vacuum insulation to:
Please tick and send by e-mail to or by fax to: [email protected] : +49 9181 6946-71
| Moosweg 12 | D-92318 Neumarkt i.d.OPf. | Tel.: +49 9181 6946-10 | Fax: 6946-71 | [email protected] | www.variotec.deVARIOTEC GmbH & Co. KG Werk 2
Name, first name:
Company:
Function:
Street:
Post code, place:
Phone:
E-mail:
Price overview „Einfach-Sicher-Dämmen“ vacuum insulation
Product overview
Consultation appointment on the ground or in the premises of VARIOTEC
Send documentation by:
e-mail:_____________________________________________________________
fax: _________________________ post
Test certificates
SAFE & SPEED „ “Stock programme
Conventional
insulation
Vacuum
insulation
The difference Factor 1:5ð
recall
Gauben-Erkerdämmung Pfostenriegelfassade
Stand: März 2018
Free of charge layout drawing
SAFE & SPEED...when it has to go fast!
...from one of the leading suppliers!
Up date: November 2018
Prefabricated VIP elements in
20 mm 30 mmand on stock
Stock programme vacuum insulation
VARIOTEC GmbH & Co. KG Werk 2
Moosweg 12
D-92318 Neumarkt i.d.OPf.
Tel.: +49 9181 6946-10 | Fax: 6946-71
[email protected] | www.variotec.de
Only in on your site!8 days
Safe & Speed VIP blank
(unlaminated)
Safe & Speed R-Gummi
(rubber)
Safe & Speed XPS
unlaminated vacuum insulation laminated with rubber granulate on both sides laminated with XPS on both sides
3 designs as available at short notice!standard sizes
for external and internal insulation
Lambda value 0,007 W/(mK) as rated value (initial value: 0,0043 W/(mK))
Operational areas amongst others as:
flat roof, balcony and terrace insulation, internal floor insulation, cooling industry and many more
Thickness comparison
www.variotec.de start productsð ð
ð VIP/QASA vacuum insulation system
VARIOTECVacuum insulation
Conventional insulation
Vacuum insulation
Technical approval Z.23.11.1779 from DIBt, fire protection B2* certified
(*Panel core/ Support core is not inflammable and is assigned to fire protection class A1)
QASA/VIP Technology and processing
Ms. Häberl: +49 9181 6946-29
E-mail: [email protected]
QASA/VIP Inquiries and orders
Ms. Schmid: +49 9181 6946-10
E-mail: [email protected]
Technical drawings (details) as well as tender texts can be found in our download area
http://www.variotec.de/start/downloads/vip-qasa-vakuumdaemmung
Free of charge layout drawingsend form
Data sheet type: ______________________________________________________
Texts for invitation to tender and details type:_______________________________
Hand sample Element Type:_____________________________________________
KI Aula Stockholm,
Architect Gert Winghards
Installed QASA B1 area in Munich,
Ackermannbogen Architect Werle
VARIOTEC GmbH & Co. KG Werk 2
Moosweg 12
D-92318 Neumarkt i.d.OPf.
Tel.: +49 9181 6946-10 | Fax: 6946-71
[email protected] | www.variotec.de
www.variotec.de start productsð ð
VIP/QASA vacuum insulationð
References
page 12
Solon AG Adlershof
Architect Schulte-Frohlinde
VARIOTEC GmbH & Co.KG WERK 2 - Production of vacuum insulation
VARIOTECVacuum insulation