18
1. APARTMENT BUILDING ENTRANCE HALL UP TO 100 NAMES 2. ENTRANCE HALL AND NOTICE BOARD UP TO 1,000 NAMES 3. ENTRANCE HALL WITH KEY SAFE UP TO 1,000 NAMES 4. NOTICE BOARD 5. KEY SAFE 1 call button 6. HALL AND ENTRY VESTIBULE UP TO 1,000 NAMES 7. 2 ENTRANCE HALLS (WITH WIRING) UP TO 1,000 NAMES 8. 2 ENTRANCE HALLS (NO WIRING) UP TO 1,000 NAMES 9. 2 ENTRANCE HALLS, BASEMENT AND SHARED CAR PARK UP TO 1,000 NAMES 10. GATE/PEDESTRIAN GATE AND ENTRANCE HALLS UP TO 1,000 NAMES 11. GATE/PEDESTRIAN GATE AND 2 GSM HAUSSMANN CODED KEYPADS 12. GATE AND PEDESTRIAN GATE UP TO 4 NAMES 13. GATE AND PEDESTRIAN GATE (WITH RF RECEIVER) UP TO 1,000 NAMES 14. GATE AND PEDESTRIAN GATE (WITH 2 READERS FOR PEDESTRIAN ENTRY/EXIT) UP TO 1,000 NAMES 15. PEDESTRIAN GATE - BICYCLE STORAGE - BASEMENT (WITH LIGHT CENTRAL UNIT) 16. RW CAR PARK 17. GSM GATE AND UNDERGROUND CAR PARK 18. GSM ISOLATED DOOR 19. GSM GATE AND CAR PARK DOOR (OUTDOORS) 20. TECHNICAL ALERT BASIC DIAGRAMS www.intratone.com

Transcript of 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000...

Page 1: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

1. APARTMENT BUILDING ENTRANCE HALL UP TO 100 NAMES

2. ENTRANCE HALL AND NOTICE BOARD UP TO 1,000 NAMES

3. ENTRANCE HALL WITH KEY SAFE UP TO 1,000 NAMES

4. NOTICE BOARD

5. KEY SAFE 1 call button

6. HALL AND ENTRY VESTIBULE UP TO 1,000 NAMES

7. 2 ENTRANCE HALLS (WITH WIRING) UP TO 1,000 NAMES

8. 2 ENTRANCE HALLS (NO WIRING) UP TO 1,000 NAMES

9. 2 ENTRANCE HALLS, BASEMENT AND SHARED CAR PARK UP TO 1,000 NAMES

10. GATE/PEDESTRIAN GATE AND ENTRANCE HALLS UP TO 1,000 NAMES

11. GATE/PEDESTRIAN GATE AND 2 GSM HAUSSMANN CODED KEYPADS

12. GATE AND PEDESTRIAN GATE UP TO 4 NAMES

13. GATE AND PEDESTRIAN GATE (WITH RF RECEIVER) UP TO 1,000 NAMES

14. GATE AND PEDESTRIAN GATE (WITH 2 READERS FOR PEDESTRIAN ENTRY/EXIT) UP TO 1,000 NAMES

15. PEDESTRIAN GATE - BICYCLE STORAGE - BASEMENT (WITH LIGHT CENTRAL UNIT)

16. RW CAR PARK

17. GSM GATE AND UNDERGROUND CAR PARK

18. GSM ISOLATED DOOR

19. GSM GATE AND CAR PARK DOOR (OUTDOORS)

20. TECHNICAL ALERT

BASI

C DI

AGRA

MS

www.intratone.com

Page 2: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com8

THE 3G-IP MODULE

ENTRANCE HALL OPENING

INTERCOM

EXIT PUSHBUTTONNot supplied

Not supplied

2 /

/ 2

2

/

2

/

4

/

2

/

12/24 V DC2A

C1

4 /

AUDIO

VIDEO 1

HOW THE INSTALLATION WORKS

- The residents' badges open the entrance hall.

- Visitors call residents using the intercom.

- The residents open the entrance hall using the key on their telephone (for example).

EQUIPMENT REQUIRED

- 1 complete intercom pack and 100-name central unit (cf. p. 34),

- 1 3G-IP unit included in the INTRATONE TELECOM BOXEO package, supplied on subscription to the contract.

Power supply to be wired as close as possible to the central unit.

Max. distance of 100 m between each unit with 0.8 mm twisted cable.

APARTMENT BUILDING ENTRANCE HALL UP TO 100 NAMES

1.

Page 3: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

BASI

C DI

AGRA

MS

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com 9

ENTRANCE HALL AND NOTICE BOARD UP TO 1,000 NAMES

HOW THE INSTALLATION WORKS

- The residents' badges open the entrance hall.

- Visitors call residents using the intercom.

- The residents open the entrance hall using the key on their telephone (for example).

- The site manager communicates with residents using the notice board in the entrance hall.

EQUIPMENT REQUIRED

- 1 complete intercom pack and 1,000-name central unit (cf. p. 32),

- 1 notice board (cf. p. 42),

- 1 3G unit included in the INTRATONE TELECOM package, 3G module(s) supplied on subscription to the contract.

* optional extra: connection of a remote video camera (Video 2).

Power supply to be wired as close as possible to the central unit.

Max. distance of 100 m between each unit with 0.8 mm twisted cable.

3G MODULE

VIDEO 1

ENTRANCE HALL OPENING

INTERCOM

EXIT PUSHBUTTONNot supplied

C1 C26

/

6

/

2

/2

/

2

/

2

/12/24 V DC2A

2

/

2 /

3 /

24 V DC 2A

Not supplied

Not supplied

REMOTE CAMERA

NOTICE BOARD

Not supplied

2.

Page 4: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com10

HOW THE INSTALLATION WORKS

- The residents' badges open the entrance hall.

- Visitors call residents using the intercom.

- Residents open the door using the key on their telephone (for example).

- An external person (carrying out meter reading, lift maintenance, etc.) can borrow the keys to the technical services rooms, stored in the key safe. Opening is by means of a code or a dedicated badge or by calling from the intercom.

EQUIPMENT REQUIRED

- 1 complete pack, 1,000 names, with invisible camera Visio intercom and "Exclusive"- version key safe (p. 85),

- 1 3G-IP unit included in the INTRATONE TELECOM BOXEO package, supplied on subscription to the contract.

Power supply to be wired as close as possible to the central unit.

Max. distance of 100 m between each element with 0.8 mm twisted cable.

THE 3G-IP MODULE

ENTRANCE HALL OPENING

INTERCOM WITH KEY SAFE

EXIT PUSHBUTTON

Not supplied

C1 C2

6

/

6

/

2

/

2

/

2

/12/24 V DC2A

2

/VIDEO 1

Not supplied

ENTRANCE HALL WITH KEY SAFE UP TO 1,000 NAMES

3.

Page 5: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

BASI

C DI

AGRA

MS

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com 11

24 V DC2A

3G MODULE

4

/

2

/

NOTICE BOARD

Not supplied

HOW THE INSTALLATION WORKS

The site manager communicates with residents using the notice board in the entrance hall.

EQUIPMENT REQUIRED

- 1 notice board (cf. p. 42),

- 3G Data unit, including unlimited Data updates, guaranteed for 15 years.

NOTICE BOARD

KEY SAFE 1 call button

4.

5.

GPRS MODULE

KEY SAFE1 CALL BUTTON

6

/

2

/12/24 V DC2A

Not supplied

HOW THE INSTALLATION WORKS

An external person (meter reading, lift maintenance, etc.) can borrow the keys to the technical services rooms, stored in the key safe. Opening is controlled with a dedicated badge on the spot or remotely via the call button (the person in charge of the keys answers and opens by pressing a key on their phone).

EQUIPMENT REQUIRED

- 1 IntraBox DATA ECO key safe with 1 call button (the 3G unit is supplied with the equipment), includes 15 years of updates (p. 56)

or

- 1 IntraBox DATA ECO communicating key safe with proximity reader (the GPRS unit is supplied with the equipment), includes 10 years of updates (p. 57).

Power supply to be wired as close as possible to the central unit.

Max. distance of 100 m between each unit with 0.8 mm twisted cable.

Page 6: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com12

ENTRANCE HALL AND ENTRY VESTIBULE UP TO 1,000 NAMES

6.

HOW THE INSTALLATION WORKS

- The residents' badges open the entrance hall and the entry vestibule.

- Visitors call residents using the intercom.

- The residents open: the entrance hall + entry vestibule (at the same time) using the key on their telephone (for example).

This case is typical of entry vestibules located "close" to entrance halls.

EQUIPMENT REQUIRED

- 1 complete pack with intercom and 1,000-name central unit (cf. p. 34),

- 1 proximity reader,

- 1 recessed box for proximity reader,

- 1 3G block included in the INTRATONE TELECOM package, 3G module(s) supplied on subscription to the contract.

* optional extra: connection of a remote video camera (Video 2).

Power supply to be wired as close as possible to the central unit.

Max. distance of 100 m between each element with 0.8 mm twisted cable.

ENTRANCE HALL OPENING

INTERCOM

EXIT PUSHBUTTONEXIT PUSHBUTTONNot suppliedNot supplied

Not supplied

C1 C2

6

/

2

/

2

/

3G MODULE

ENTRY VESTIBULE OPENING

READER

6

/

4

/

2

/

2

/

VIDEO 1

2

/12/24 V DC2A

2

/

2 /REMOTE CAMERA

Not supplied

Page 7: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

BASI

C DI

AGRA

MS

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com 13

2 ENTRANCE HALLS (with wiring) UP TO 1,000 NAMES

7.

HOW THE INSTALLATION WORKS

- The residents' badges open their entrance hall.

- Visitors call residents using the intercom.

- The residents open the door to their entrance hall using the key on their telephone (for example).

EQUIPMENT REQUIRED

- 1 complete pack with intercom and 1,000-name central unit (cf. p. 33 and p. 35),

- 1 intercom only (cf. p. 32 and p. 34),

- 1 extension card (cf. p. 48),

- 1 3G block included in the INTRATONE TELECOM package, 3G module(s) supplied on subscription to the contract.

N.B. No remote video camera.

Power supply to be wired as close as possible to the central unit.

Max. distance of 100 m between each unit with 0.8 mm twisted cable.

C3 C4

3G MODULE

ENTRANCE HALL 2 OPENING

INTERCOM

INTERCOM

VIDEO 1

EXTENSION CARD

EXIT PUSHBUTTON

EXIT PUSHBUTTON

Not supplied

Not supplied

C26

/

6

/

2

/

2

/

2

/

2

/

C1

6

/

2

/12/24 V DC3A

2

/

2 /

VIDEO 2

Not supplied

ENTRANCE HALL 1 OPENING

Page 8: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com14

HOW THE INSTALLATION WORKS

- The residents' badges open their entrance hall.

- Visitors call residents using the intercom.

- The residents open the door to their entrance hall using the key on their telephone (for example).

This case is typical of 2 halls which cannot be connected.

EQUIPMENT REQUIRED

- 2 complete packs with intercom and 1,000-name central unit (cf. p. 34),

- 2 3G units included in the INTRATONE TELECOM package, 3G module(s) supplied on subscription to the contract.

* optional extra: connection of a remote video camera (Video 2).

Power supply to be wired as close as possible to the central unit.

Max. distance of 100 m between each element with 0.8 mm twisted cable.

3G MODULE

ENTRANCE HALL 1 OPENING

HALL 1

HALL 2 IDENTICAL SET-UP FOR EACH HALL

INTERCOM

EXIT PUSHBUTTONNot supplied

C1 C2

6

/

6

/

2

/

2

/

2

/12/24 V DC2A

2

/VIDEO 1

2 /

Not supplied

REMOTE CAMERANot supplied

2 ENTRANCE HALLS (no wiring) UP TO 1,000 NAMES

8.

Page 9: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

BASI

C DI

AGRA

MS

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com 15

2 ENTRANCE HALLS, BASEMENT AND SHARED CAR PARK UP TO 1,000 NAMES

9.

21

C3 C4

ENTRANCE HALL 2 OPENING

INTERCOM

EXTENSION CARD

EXIT PUSHBUTTON

Not supplied

Not suppliedNot supplied

Not supplied

Not suppliedNot supplied

C2 C2

4

/

4

/

2

/

2

/

/ 2

2

/

6

/

2

/

2

/2

/

2

/2

/

2

/2

/

C1 C1

6

/4

/

12/24 V DC3A 12/24 V DC

2A

CAR PARK OPENING

ENTRANCE HALL 1 OPENING

RF RECEIVERINTERCOM

EXIT PUSHBUTTON

6

/

EXIT PUSHBUTTON

EXIT PUSHBUTTON

2

/

3G MODULE

VIDEO 1

VIDEO 2

READER

READER

2

/BASEMENT 1 OPENING

BASEMENT 2 OPENING

3

/ OPTIONAL CENTRAL UNIT

HOW THE INSTALLATION WORKS

- The residents' badges open an entrance hall and a basement.

- The remote controls also open the car park.

Visitors call residents using the intercoms.

- Residents open the entrance hall using the key on their telephone (for example).

This case is typical of an installation in 2 building entrance halls with a shared car park.

EQUIPMENT REQUIRED

- 2 complete packs with intercom and 1,000-name central unit (cf. p. 33 and p. 35),

- 2 proximity readers (cf. p. 70),- 2 built-in wall boxes for proximity reader

(cf. p. 79),- 1 extension card (cf. p. 48),- 1 RF receiver, (cf. p. 62),- 1 3G block included in the INTRATONE TELECOM

package, 3G module(s) supplied on subscription to the contract.

N.B. No remote video camera.Power supply to be wired as close as possible to the central unit.Max. distance of 100 m between each unit with 0.8 mm twisted cable.

Page 10: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com16

HOW THE INSTALLATION WORKS

- The residents' badges open the gate (pedestrians) and the entrance hall to their apartment building.

- The remote controls open the gate (vehicles).

- The Mobile keys open the gate (vehicles).

- Visitors call residents using the intercom.

- The residents open: - the pedestrian gate using the key on their

telephone (for example). - the vehicle gate using the # key on their

telephone (for example).

This case is typical of a "residential conversion".

EQUIPMENT REQUIRED

- 2 complete packs with intercom and 1,000-name central unit (cf. p. 33 and p. 35),

- 1 intercom only (cf. p. 32 and p. 34),

- 1 RF receiver (cf. p. 63),

- 1 extension card (cf. p. 48).

* optional extra: connection of a remote video camera (Video 2).

Power supply to be wired as close as possible to the central unit.

Max. distance of 100 m between each unit with 0.8 mm twisted cable.

Not supplied

Not supplied

Not supplied

Not supplied

Not suppliedNot supplied

C2

C2

2

/

2

/

2

/

2

/

6

/

6

/

2

/

2

/2

/

2

/

2

/

2

/2

/

C1

C1

12/24 V DC2A

12/24 V DC3A

PEDESTRIAN GATE OPENING

ENTRANCE HALL 1 OPENING

ENTRANCE HALL 2 OPENING

INTERCOM 1 PEDESTRIAN GATE

INTERCOM 2 HALL 1

INTERCOM 3 HALL 2

EXIT PUSHBUTTON

EXIT PUSHBUTTONEXIT PUSHBUTTON

6

/

6

/

RF RECEIVER

4

/

3G MODULE

3G MODULE

REMOTE CAMERA

VIDEO 1

VIDEO 1

VIDEO 2

2 /

6 /

EXTENSION CARD

2

/GATE OPENING

GAT

E &

PED

ESTR

IAN

GAT

EH

ALL

1 A

ND

HA

LL 2

GATE/PEDESTRIAN GATE AND ENTRANCE HALLS UP TO 1,000 NAMES

10.

Page 11: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

BASI

C DI

AGRA

MS

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com 17

GATE/PEDESTRIAN GATE AND 2 ENTRANCE HALLS GSM HAUSSMANN CODED KEYPAD

11.

Not supplied

Not supplied

Not supplied

Not supplied Not supplied

C2

2

/

2

/

6

/

2

/

2

/

C1

12/24 V DC2A

PEDESTRIAN GATE OPENING

INTERCOM 1 PEDESTRIAN GATE

EXIT PUSHBUTTON

6

/

RF RECEIVER

4

/

3G MODULE

VIDEO 1

2 /

Not supplied Not supplied

2

/2

/

4

/4

/

2

/2

/

2

/2

/

12/24 V DC2A

12/24 V DC2A

ENTRANCE HALL 2 OPENING

ENTRANCE HALL 1 OPENING

HAUSSMANN KEYPAD

HAUSSMANN KEYPAD

EXIT PUSHBUTTON EXIT PUSHBUTTON

4

/4

/GPRS MODULE GPRS MODULE

GATE OPENING

2

/

REMOTE CAMERA

C1 C1

HOW THE INSTALLATION WORKS

- The residents' badges open the gate (pedestrian).- The residents type in a code in order to enter the

entrance hall of their building.- The remote controls open the gate (vehicles).- The Mobile keys open the gate (vehicles). - Visitors call residents using the intercom.- The residents open: - the pedestrian gate using the key on their

telephone (for example). - the vehicle gate using the # key on their

telephone (for example).This case is typical of a "residential conversion".

EQUIPMENT REQUIRED

- 1 complete pack with intercom and 1,000-name central unit (cf. p. 33),

- 1 RF receiver (cf. p. 63),

- 1 3G unit included in the INTRATONE TELECOM package, 3G module(s) supplied on subscription to the contract,

- 2 IntraBox Data Eco Haussmann coded keypad (the GPRS unit is supplied with the equipment) (cf. p. 55).

* optional extra: connection of a remote video camera (Video 2).

Power supply to be wired as close as possible to the central unit.

Max. distance of 100 m between each element with 0.8 mm twisted cable.

Page 12: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com18

HOW THE INSTALLATION WORKS

- The remote controls open the gate.

- Residents open the pedestrian gate using the "1" key on their telephone (for example).

- The Mobile keys open the gate.

EQUIPMENT REQUIRED

- 1 Villa intercom pack, 1 to 4 buttons (cf. p. 36 or 38). Everything is included: the RF receiver, the remote controls.

Power supply to be wired as close as possible to the central unit.

Max. distance of 100 m between each element with 0.8 mm twisted cable.

DOOR 2 OPENING

DOOR 1 OPENING

EXIT PUSHBUTTONEXIT PUSHBUTTONNot suppliedNot supplied

2

/

2

/2

/

2

/

2

/2

/POWER SUPPLY UNIT

VILLA INTERCOM

Not supplied

12/24 V AC/DC1A

GATE AND PEDESTRIAN GATEUP TO 4 NAMES

12.

Page 13: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

BASI

C DI

AGRA

MS

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com 19

HOW THE INSTALLATION WORKS

- The residents' badges open the gate (pedestrian).

- The remote controls open the gate (vehicles).

- The Mobile keys open the gate (vehicles).

- Visitors call residents using the intercom.

- The residents open:

- the pedestrian gate using the key on their telephone (for example).

- the vehicle gate using the # key on their telephone (for example).

This case is typical of a "residential conversion".

EQUIPMENT REQUIRED

- 1 complete pack with intercom and 1,000-name central unit (cf. p. 32),

- 1 watertight RF receiver (cf. p. 63),

- 1 3G block included in the INTRATONE TELECOM package, 3G module(s) supplied on subscription to the contract.

* optional extra: connection of a remote video camera (Video 2).

Power supply to be wired as close as possible to the central unit.

Max. distance of 100 m between each unit with 0.8 mm twisted cable.

3G MODULE

PEDESTRIAN GATE OPENING

RF RECEIVER

INTERCOM

EXIT PUSHBUTTONNot supplied

6

/

4

/

6

/

2

/

2

/2

/

12/24 V DC2A

2

/

2

/

REMOTE CAMERA

VIDEO 1

2 /

GATE OPENING

Not supplied

Not supplied

C1 C2

GATE AND PEDESTRIAN GATE (WITH RF RECEIVER) UP TO 1,000 NAMES

13.

Page 14: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com20

HOW THE INSTALLATION WORKS

- The residents' badges open the gate (pedestrian).

- The remote controls open the gate (vehicles).

- The Mobile keys open the gate (vehicles).

- Visitors call residents using the intercom.

- The residents open: - the pedestrian gate using the key on their

telephone (for example). - the vehicle gate using the # key on their

telephone (for example).

This case is typical of a "residential conversion".

EQUIPMENT REQUIRED

- 1 complete intercom pack and 1,000-name central unit (cf. p. 32),

- 1 proximity reader (cf. p. 70),- 1 recessed box for proximity reader (cf. p. 79),- 1 extension card (cf. p. 48),- 1 watertight RF receiver (cf. p. 62),- 1 3G block included in the INTRATONE TELECOM

package, 3G module(s) supplied on subscription to the contract.

* optional extra: connection of a remote video camera (Video 2).Power supply to be wired as close as possible to the central unit.Max. distance of 100 m between each unit with 0.8 mm twisted cable.

VIDEO 1

2 /3G MODULE

GATE OPENINGPEDESTRIAN GATE OPENING

INTERCOM

EXIT PUSHBUTTONNot supplied

6

/

4

/

6

/

2

/2

/

2/

2

/

12/24 V DC3A

EXTENSION CARD

RF RECEIVER 4/

2

/2

/Not supplied

Not supplied

REMOTE CAMERA

C1

C3

C2

GATE OPENING

GATE AND PEDESTRIAN GATE (WITH 2 PEDESTRIAN ENTRY/EXIT READERS) - UP TO 1,000 NAMES

14.

PROXIMITY READER

Page 15: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

BASI

C DI

AGRA

MS

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com 21

HOW THE INSTALLATION WORKS

The residents open the door to the car park using their remote controls.

EQUIPMENT REQUIRED

- 1 RF receiver RW (cf. p. 64-65).

Power supply to be wired as close as possible to the RF receiver.

Max. distance of 100 m between each unit with 0.8 mm twisted cable.

RF RECEIVER

2

/

12/24 V AC/DC100mA

Not supplied

GATE OPENING

HOW THE INSTALLATION WORKS

- The residents open the door with their badge.

EQUIPMENT REQUIRED

- Light central units with proximity reader for access points 1 and 2 (cf. p. 67),

- Built-in wall boxes for proximity reader for access points 1 and 2 (cf. p. 79),

- Intratone stand-alone handle (cf. p. 71).Power supply to be wired as close as possible to the central unit.Max. distance of 100 m between each unit with 0.8 mm twisted cable.

1

2 3

12/24 V DC10/20 V AC 1A

IDENTICAL CONFIGURATION FOR ACCESS POINTS 1 AND 2

EXIT PUSHBUTTON

ACCESS POINT 3

CENTRAL UNIT INTRALIGHT

Not supplied

Stand-aloneNo wiring

2

/

2

/4

/

C1

PEDESTRIAN GATE, BICYCLE STORAGE or BASEMENT OPENING

Not supplied

PROXIMITY READER

PEDESTRIAN GATE - BICYCLE STORAGE - BASEMENT (WITH LIGHT CENTRAL UNIT)

CAR PARKRW

15.

16.

Page 16: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com22

HOW THE INSTALLATION WORKS

- The residents' badges open the door.

- The Mobile keys open the door.

EQUIPMENT REQUIRED

- 1 IntraBox DATA ECO proximity reader (the GPRS unit is supplied with the equipment) (cf. p. 53). Including 10 years of updates.

Power supply to be wired as close as possible to the central unit.

Max. distance of 100 m between each unit with 0.8 mm twisted cable.

12/24 V DC2A

DOOR OPENING

EXIT PUSHBUTTONNot supplied

2

/

2

/

2

/4

/

GPRS MODULE

4

/

C1

Not supplied

HOW THE INSTALLATION WORKS

The residents open the pedestrian gate with their remote control or their mobile phone (Mobile key service).

EQUIPMENT REQUIRED

- 1 IntraBox ECO DATA RF (the GPRS unit is supplied with the equipment) (cf. p. 52).

Power supply to be wired as close as possible to the GPRS module.

Max. distance of 100 m between each unit with 0.8 mm twisted cable.

GATE OPENING

RF RECEIVER

GPRS MODULE

4

/

2

/

2

/12/24 V DC2A

Not supplied

GATE AND UNDERGROUND CAR PARK GSM

ISOLATED DOOR GSM MODULE

17.

18.

PROXIMITY READER

Page 17: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

BASI

C DI

AGRA

MS

TECHNICAL SUPPORT: [email protected] / +33 (0) 251 655 529Remote management site: www.intratone.com 23

HOW THE INSTALLATION WORKS

An alert is sent by email in the event of a malfunction of the equipment connected (ventilation system, boiler, etc.).

EQUIPMENT REQUIRED

- 1 IntraBox DATA ECO Technical Alert (the GPRS unit is supplied with the equipment) (cf. p. 58). Including 10 years of updates.

N.B. Up to 4 alerts with 3 additional relay cards.

Power supply to be wired as close as possible to the GPRS module.

Max. distance of 100 m between each unit with 0.8 mm twisted cable.

12/24 V DC2A

ALERT 1VENTILATION SYSTEM, PUMP, BOILER, ETC.

2

/

2

/GPRS MODULE

Not supplied

GATE AND CAR PARK DOOR (OUTDOORS) GSM

TECHNICAL ALERT

19.

20.

CODED KEYPAD

GPRS MODULE

2

/

2

/12/24 V DC2A

Not supplied

HOW THE INSTALLATION WORKS

The residents open the pedestrian gate with their remote control or their mobile phone (Mobile key service).

EQUIPMENT REQUIRED

- 1 IntraBox DATA mini RF (cf. p. 60)

or

- 1 IntraBox DATA mini RF Coded keypad (cf. p. 61).

Power supply to be wired as close as possible to the GPRS module.

Max. distance of 100 m between each unit with 0.8 mm twisted cable.

Page 18: 1. APARTMENT BUILDING ENTRANCE HALL · up to 1,000 names 3.entrance hall with key safe up to 1,000 names 4.notice board 5.key safe 1 call button 6.hall and entry vestibule up to 1,000

VIDEO calls, image on compatible mobile phone

Equipment suitable for everyone

Equipment can be connected to mobile telephone networks

Equipment can be connected to mobile telephone networks

Read/write management Real-time management Equipment designed to withstand vandalism

VIDEO / VISIO

VANDAL RESISTANT

SYMBOLS USED

[no voice]

intercom systems

access control

key management

A complete range to secure all access points

Real-time and remote management tools, free and evolving!

SUITABLE FOR EVERYONE

www.intratone.com

24