1 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
TEST REPORT
IES LM-79-08
Electrical and Photometric Measurements of Solid-State Lighting Products
Report reference No……..……..……..…….….: FLOODLIGHT14.0513.01
Date of issue …..……..………....…....…..……..: 2014-05-13
Project handler…………..……..……........…….: Eric
Testing laboratory…....……..….....……...……: Shanghai Baiyi Lighting Electronic Co., Ltd
Address…………..……..……..……..…….….….…: No.1188,Jiuye Road Qingpu District,201700 Shanghai City China
Testing location……..……..……..…….….….…: Same as above.
Client……………..……..……..……..….........……: BAIYILED Europe B.V.
Client number………..…..…………….…....……: N/A
Address……..……..……..……..……….….……….: Minervum 7113, 4817ZN, Breda , The Netherlands
Contact person…….……..……..……..…….…..: Jack Niu
Standard………………..……..……..……..……….: This test program is based on the following requirements:IES LM-
79-08
TRF originated by…………..……..……...……..: Baiyi Group Product Service
Copyright blank test report……………..……: This test report is based on the content of the standard(see
above). The test report considered selected clauses of the a.m.
standard(s) and experience gained with product testing. It was
prepared by Shanghai Baiyi Lighting Electronic Co., Ltd.
Baiyi Group takes no responsibility for and will not assume liability for
damages resulting from the reader’s interpretation of the reproduced material
due to its placement and context.
Non-standard test method……….………....:N
National deviations…..……..……..…………..:N
Number of pages(report)…….…….……..…:12
Number of pages (Attachments)..……..…:2
Compiled by……. Eric Approved by……Connie
2 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
Test sample…………….…….……………..……..: 1 sample
Type of test object…………..……………….…: Flood Light
Trade mark…………………..…..…….…….….…: BAIYILED
Model and/or type reference……....…….: BY-TGC-120W
Ratting(s)………………….…….…………..…...…:AC100-240V 50/60Hz
Manufacturer………………………………..….…:Same as client.
Manufacturer number…………….……….….:N
Address…………………………….……..….………:Same as client.
Order description……………..…………..…….: Complete test according to TRF
Partial test according to manufacturer’s specifications
Preliminary test
Spot check
Other
Date of order……………………………….….….: 2014-05-12
Date of receipt of test item….……..………: 2014-05-13
Date of performance of test……..…………: 2014-05-12 to 2014-05-13
Test item particulars(declared):
Lamp type Bare lamp
Covered lamp, no reflector
Lamp with reflector
other: LED FLOODLIGHT
Lamp cap installed: N
Rated Voltage:AC100-240V, 50/60Hz
Rated Power:120W
Rated Power Factor: N
Rated Luminous Flux:10800lm
Rated CCT:4000K
Rated CRI: N
Attachments:
1. Test Equipment List
2. Uniform Reporting Template
3 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
General remarks
“(see remarks#)”refers to a remark appended to the report.
(see appended table)refers to a table appended to the report
Throughout this report a point is used as the decimal separator
The test results presented in this report relate only to the object tested.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
Measurement uncertainty budgets have been determined for applicable test methods and are available
The report must not be used by the client to claim product certification.
Summary of testing:
Model Luminous Efficacy
(lm/w)
Luminous Flux
(lm)
Input Power
(w) Power Factor
BY-TGC-120W 105.39 12305 116.76 0.9920
Model CCT(K) CRI ISTMT
(In-Situ Temp Test)(℃)
Stabilization Times
(Light Power)(minutes)
BY-TGC-120W 4119 71.3 -- 5
If additional information is necessary, please provide:
N
4 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
Copy of marking plate:
Picture of the product
Picture of In-Situ Temp Test
N
Measurement Point:
N
Characteristic data
(not shown on the marking plate)
5 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
N
Purpose of the product
(Description of intended use)
LED Luminairefor generally lighting purpose.
Possible test case verdicts:
-test case does not apply to the test object…………..…......:N(.A.)/not included in the order
-test object does meet the requirement…………………....….: P(ass)
-test object does not meet the requirement………………….: F(ail)
Possible suffixes to the Verdicts:
-suffix for detailed information for the client……………….…: C(omment)
-suffix for important information for factory inspection…: M(anufacturing)
6 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
IES LM-79-08 Clause Requirement-test Measuring result-Remark Verdict
2.0 Ambient Conditions P
2.1 General P
2.2 Air Temperature P
2.3 Thermal Condition for Mounting SSL Products P
2.4 Air Movement P
3.0 Power Supply Characteristics P
3.1 Waveshape of AC power supply P
3.2 Voltage regulation P
4.0 Seasoning of SSL Product N
No seasoning of SSL Product P
5.0 Stabilization of SSL Product P
SSL product has sufficiently stabilized before measurement
P
6.0 Operation Orientation P
SSL product shall be stabilized and measured in intended operating orientation
As normal working P
7.0 Electrical Settings P
SSL product shall be operated at rated voltage P
SSL product with dimming capability are tested at maximum input power condition
N
SSL product with different modes are measured in all relevant modes
N
8.0 Electrical Instrumentations P
8.1 Circuits P
8.2 Uncertainties N
9.0 Test methods for Luminous Flux measurement P
9.1 Integrating sphere with a spectroradiometer(sphere- spectroradiometer system)
P
9.2 Integrating sphere with a photometer head (sphere-photometer system)
N
9.3 Goniophotometer P
10.0 Luminous intensity Distribution P
Reporting acc.to IEC LM-63 P
11.0 Luminous Efficacy P
Calculation See table 1 P
12.0 Test Methods for Color Characteristics of SSL Products P
Measurements See table 1 P
13.0 Uncertainty statement N
7 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
Table1 Test data
Model BY-TGC-120W
Rated Voltage(V): AC220V 50/60Hz Rated Power(W) 120
Rated Luminous Flux (lm): 10800 Ambient temperatuere25±1(℃) 25.0
Test item Measured Value
Integrating sphere Goniophotometer
Key Photometric Results
Luminous Efficacy(lm/w) 97.64 105.39
Total Luminous Flux(lm) 11897 12305
Total Radiant Flux(W) -- --
Correlated Color Temperature(CCT:K) 4119 --
Color Rendering Index(CRI) 71.3 --
Chromaticity(Chroma x/Chroma y) 0.3740/0.3682 --
Chromaticity(Chroma u/Chroma v) / --
Chromaticity(Chroma u’/Chroma v’) 0.2243/0.4968 --
DuvValue -- --
Color Angular Uniformity(Max.du’v’) -- --
Stabilization Time(Light and Power) 5 10
Total Run Time-Integrating Sphere(Minutes) 10 --
Total Run Time- Goniophotometer(Minutes) -- 40
Spacing Criteria(C/y) N C=10°/γ=5°
Electrical Input Results
Input Power(w) 121.85 116.76
Input Voltage(V AC) 219.9 220.0
Input Current(Amps) 0.5603 0.5350
Frequency(Hz) 50 50
Power Factor 0.9890 0.9920
A-THD(Current-Total Harmonic Distortion) -- --
Additional Information
Ambient Temperature(℃) 25.0 25.0
ISTMT(In-Situ Temperature Measurement) --
Photometric measurement condition -- --
Supplementary Information:
---Absorption Correction used: Yes
---Stabilization was considered reached by:the variation (maximum-minimum) of at least 3 readings of the light output and electrical power over a period of 30 minutes is less than 0.5%.
8 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
Table 2 Spectral Flux Graph
Model BY-TGC-120W
The following graph shows the spectral response curve of the radiant flux for the sample:
Spectral response of the Radiant Flux
(350nm to 1000nm----calibrated range of the Spectroradiometer)
Wavelength
9 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
Table 3 Chromaticity Diagram
Model BY-TGC-120W
Tristimulus values(from Table 1)
0.3740/0.3682
Location is indicated by:The solid point
10 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
Table 4 Luminous Intensity distribution diagram
Model BY-TGC-120W
Luminous Intensity distribution diagram(Unit:cd)
11 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
Table 5 Planar Illuminance Curve
Model BY-TGC-120W
Planar Illuminance Curve(Unit:lx)
12 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
Table 6 Zonal flux diagram
Model BY-TGC-120W
--
13 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
Attachment 1:Equipment
Equipment ID NO. Model Brand/Manufacturer Calibration due date
Digital Power Meter PF10200101710 PF1020 WEIBO 2014-7-30
Spectral Flux Lamp
Measurement System ZWL50000606012 ZWJ-900 ZHONGWEI 2014-7-30
Temperature and
Humidity Meter 2010042489 HTC-1 YUANHENGTONG 2014-7-30
Digital Power Meter PF10200101815 PF1020 WEIBO 2014-7-30
AC Power Source 21726 HY9001 HUAYANG 2014-10-30
Temperature and
Humidity Meter 2010042492 HTC-1 YUANHENGTONG 2014-7-30
Goniophotometer
System 201006 GO-2000 EVERFINE 2014-10-30
Standard Luminous
Intensity Lamp ZWGD2013072302 24V/100W OSRAM 2014-7-22
Calibrated standard
lamp 1003019 28V/10/500cd EVERFINE 2014-7-22
14 / 14 Report No.: FLOODLIGHT14.0513.01
Test Report IES LM-79-08/Rev.00:2014-05
Attachment 2
Shanghai Baiyi Lighting Electronic Co., Ltd Lighting Facts LM-79-08 Reporting Template
Laboratory Information
Name of test lab Shanghai Baiyi Lighting Lab
Date of test report 2014-05-13
Test report number FLOOD LIGHT14.0513.01
Laboratory contact name Eric
*By signing this form, the signatory is attesting that the information on the form is correct and the same as on the original,
complete test report(s).
The signatory also attests that all of the results on this form were measured entirely in accordance with IES LM-79-08.
Product Information
Manufacturer Shanghai Baiyi Lighting Electronic Co., Ltd.
Brand name BAIYILED
Model BY-TGC-120W
SKU(if available) N
Type of Luminaire(for integral lamps, list base
type and lamp type ) LED Flood Light
Luminaire aperture(downlights) --
Luminaire length 160(mm)
Luminaire width 365(mm)
Number of units(modular products) 1pc
Electrical Measurements integrating sphere output Goniophotometer output
W
A
V
W
Photometric Characteristics
LM
LM/W
Luminous Intensity Distribution Goniophotometer output
Cd
°
%
%
%
%
END OF TEST REPORT
Input wattage 121.85 116.76
Input current 0.5603 0.5350
Input voltage(AC) 219.9 220.0
Power factor 0.9890 0.9920
Off-state power -- --
Total initial lumen output 11897 12305
Initial Luminaire efficacy 97.64 105.39
Correlated color temperature /CCT(K) 4119
Color rendering index/CRI 71.3
R9 value --
Duv --
Center beam candlepower(if applicable)
--
5225.8
Beam angle (if applicable) 74.5
Zonal lumens in the 0°-60°zone --
Zonal lumens in the 60°-90°zone --
Zonal lumens in the 90°-120°zone --
Zonal lumens in the 120°-180°zone --