098-00028-000-rev-c TP5000
Transcript of 098-00028-000-rev-c TP5000
-
8/11/2019 098-00028-000-rev-c TP5000
1/306
TimeProvider 5000IEEE 1588 Grand Master Clock
Users GuideRevision C October 2009
Part Number 098-00028-000
-
8/11/2019 098-00028-000-rev-c TP5000
2/306
Symmetricom, Inc.2300 Orchard Parkway
San Jose, CA 95131-1017
U.S.A.
http://www.symmetricom.com
Copyright 2009 Symmetricom, Inc.All rights reserved. Printed in U.S.A.
All product names, service marks, trademarks, and registered trademarks
used in this document are the property of their respective owners.
-
8/11/2019 098-00028-000-rev-c TP5000
3/306
Contents
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 3
How to Use This Guide
Purpose of This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Who Should Read This Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Structure of This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Conventions Used in This Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Warnings, Cautions, Recommendations, and Notes . . . . . . . . . . . . . . . . . . . .17
Related Documents and Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Where to Find Answers to Product and Document Questions . . . . . . . . . . . . .18
Whats New In This Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Chapter 1 Overview
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
TimeProvider 5000 Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21UTI Input and Output Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21Communications Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Output Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22Input Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24Power and Ground Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
IMC Module LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26IOC Module LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Communication Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27Synchronization and Timing Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27Synchronization and Timing Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . .27System Inputs and Outputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Configuration Management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Chapter 2 Installing
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30Site Survey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30Installation Tools and Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
-
8/11/2019 098-00028-000-rev-c TP5000
4/306
Table of Contents
4 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Unpacking the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Rack Mounting the Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Working With Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35Handling Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35Inserting Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35Removing Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Signal Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36Communications Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Synchronization and Timing Connections. . . . . . . . . . . . . . . . . . . . . . . . .38
Connecting the GPS Antenna. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Making Ground and Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Ground Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41Power Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42Testing Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Installation Check List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Applying Power to the TimeProvider 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . .44Normal Power Up Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Chapter 3 CLI Commands and SNMP
CLI Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48TimeProvider 5000 CLI Command Conventions . . . . . . . . . . . . . . . . . . .49CLI Command Keyboard Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Command Line Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50Command User Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
TimeProvider 5000 CLI Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Simple Network Management Protocol (SNMP). . . . . . . . . . . . . . . . . . . . . . .149Management Information Base. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Chapter 4 Provisioning
Establishing a Connection to the TimeProvider 5000 . . . . . . . . . . . . . . . . . . .164Communicating Through the Serial Port. . . . . . . . . . . . . . . . . . . . . . . . .164
Communicating Through the Ethernet Port . . . . . . . . . . . . . . . . . . . . . .165
-
8/11/2019 098-00028-000-rev-c TP5000
5/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 5
Table of Contents
Managing the User Access List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166Logging In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167
Adding a User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167Deleting A User. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168Displaying Current Users and User Access Levels . . . . . . . . . . . . . . . .168
Changing a Users Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169Changing a Users Access Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
Provisioning for a RADIUS Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170Provisioning the TP5000 for Login Authentication . . . . . . . . . . . . . . . . .170Configuring the RADIUS Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
Provisioning the Ethernet Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172Provisioning IMC Ethernet Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172Provisioning IOC Ethernet Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
Provisioning VLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178
Provisioning PTP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180Unicast - Dynamic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186Unicast - Static . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186
Provisioning the Programmable E1 Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . .187
Provisioning the Programmable E1 Outputs. . . . . . . . . . . . . . . . . . . . . . . . . .189
Provisioning the E1 Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191
Provisioning the 10MHz & 1PPS Outputs. . . . . . . . . . . . . . . . . . . . . . . . . . . .192
Setting the System Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
Provisioning the Input Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194Setting the GPS Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194Setting an E1 Input as Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Provisioning Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195Disabling Specific Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196Showing Current Alarm Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196Showing Current Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196Displaying Alarm and Unit Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Saving and Restoring Provisioning Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . .197Backing up Provisioning Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
-
8/11/2019 098-00028-000-rev-c TP5000
6/306
Table of Contents
6 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Provisioning for SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199Enabling the SNMP Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Adding or Deleting a Manager IP Address . . . . . . . . . . . . . . . . . . . . . . .201Provisioning to Generate v2 Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201Provisioning to Generate v3 Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
Adding and Removing v2 Communities . . . . . . . . . . . . . . . . . . . . . . . . .201Adding and Removing SNMP v3 Users . . . . . . . . . . . . . . . . . . . . . . . . .202Adding and Removing SNMP v3 Trap Users . . . . . . . . . . . . . . . . . . . . .203
Chapter 5 Operating
Logging In And Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206
Adding And Deleting Users. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206
Saving Present Configuration To Non-volatile Memory . . . . . . . . . . . . . . . . .206
Restoring Default Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206Determining Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .207
Forcing Unit To Send New Time in GPS Mode. . . . . . . . . . . . . . . . . . . . . . . .207
Switching Active And Standby IOC Cards . . . . . . . . . . . . . . . . . . . . . . . . . . .208Manually Switching IOC Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
Automatic IOC Card Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208Impact of IOC Card Switches on IO Card Outputs . . . . . . . . . . . . . . . . .209
Displaying Logs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210Displaying Alarms Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210
Displaying Events Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210Restarting the TimeProvider 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
Managing PTP Clients . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .211Configuring PTP Clients . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212Monitoring PTP Client Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . .213Monitoring PTP Client Alarm / Event Information . . . . . . . . . . . . . . . . . .214Upgrading PTP Client Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Chapter 6 Maintenance and Troubleshooting
Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218
Safety Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218
ESD Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219Diagnosing the IOC - Reading LED Conditions . . . . . . . . . . . . . . . . . . .222Diagnosing the IMC - Reading LED Conditions . . . . . . . . . . . . . . . . . . .226
-
8/11/2019 098-00028-000-rev-c TP5000
7/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 7
Table of Contents
Repairing the TimeProvider 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228Removing the IOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229Replacing the IOC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229Replacing the IMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232
Obtaining Technical Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233
Upgrading the Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233Upgrading From TP5000 v1.0 to v1.1. . . . . . . . . . . . . . . . . . . . . . . . . . .233Upgrading the IOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .239Upgrading the IMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240
TimeProvider 5000 Part Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242System and Accessory Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . .242GPS Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244
Returning the TimeProvider 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245Repacking the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245
Equipment Return Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245Users Guide Updates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246
Appendix A System Messages
Message provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248Facility codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248Severity codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248
System Notification Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .249
Appendix B Specifications and Factory Defaults
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .267Serial Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .267LAN Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .267Input Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268
Clocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .269
Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270
Reference Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .276
-
8/11/2019 098-00028-000-rev-c TP5000
8/306
Table of Contents
8 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Appendix C Installing the GPS Antenna
Antenna Kits and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .280Selecting the Proper Gain Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . .280Transient Eliminators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .282
GPS L1 Inline Amplifier. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .283Antenna Coaxial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .284
Installing Antennas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284Antenna Connection Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285Planning the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285
Antenna Installation Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . .288Cutting Antenna Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .288Installing the Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289Connecting the Cable to the Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . .289Installing the Transient Eliminator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .290
Installing the Antenna Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291Connecting the GPS Antenna. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .291
Antenna Installation Completeness Checklist. . . . . . . . . . . . . . . . . . . . .292
Contacting Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .293
Appendix D Software Licenses
Third-Party Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .296
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .297
-
8/11/2019 098-00028-000-rev-c TP5000
9/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 9
Figures
1-1 TimeProvider 5000 Connectors and LEDs . . . . . . . . . . . . . . . . . . . . . . . . .211-2 Serial Port Male Connector Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221-3 I/O Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
1-4 PTP Output Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231-5 GPS Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241-6 Power and Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251-7 TimeProvider 5000 Modules and Power Connections. . . . . . . . . . . . . . . . .251-8 TimeProvider 5000 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .262-1 Location of Product Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .322-2 Mounting Hole Placements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .332-3 Chassis Dimensions - Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .332-4 Chassis Dimensions - Top View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .342-5 Rack Mounting the TimeProvider 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . .342-6 IMC Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
2-7 Serial Port Male Connector Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .372-8 PTP Output Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .382-9 E1 Output Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .392-10 TimeProvider 5000 Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . .412-11 Universal Ground Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .412-12 TimeProvider 5000 Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . .422-13 Power and Ground Connections on the TimeProvider 5000 . . . . . . . . . . . .433-1 TimeProvider 5000 CLI Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . .483-2 Checking HW / SW and Card-to-Card Compatibility . . . . . . . . . . . . . . . . .843-3 TP5000 MIB - Top Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1503-4 TP5000 MIB - Inventory Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150
3-5 TP5000 MIB - Status Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1503-6 TP5000 MIB - sysStatus Node. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1513-7 TP5000 MIB - activeAlarmAndEvent Node . . . . . . . . . . . . . . . . . . . . . . . .1513-8 TP5000 MIB - networkStatus Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1513-9 TP5000 MIB - gpsInfo Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1523-10 TP5000 MIB - ptpStatus Node. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1523-11 TP5000 MIB - craftPort Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1533-12 TP5000 MIB - inOutStatus Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1533-13 TP5000 MIB - Configuration Node. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1533-14 TP5000 MIB - inventoryConfig Node. . . . . . . . . . . . . . . . . . . . . . . . . . . . .1533-15 TP5000 MIB - alarmConfig Node. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1533-16 TP5000 MIB - sysGeneral Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1543-17 TP5000 MIB - Network Node. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1553-18 TP5000 MIB - inputOutput Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1563-19 TP5000 MIB - PTP Node. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1573-20 TP5000 MIB - GPS Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1573-21 TP5000 MIB - ptpLock Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1573-22 TP5000 MIB - ptpClientManagement Node. . . . . . . . . . . . . . . . . . . . . . . .158
-
8/11/2019 098-00028-000-rev-c TP5000
10/306
List of Figures
10 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
3-23 TP5000 MIB - ptpNodeInfo Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1583-24 TP5000 MIB - ptpNodeInfo Node (contd) . . . . . . . . . . . . . . . . . . . . . . . . .1593-25 TP5000 MIB - ptpNodeControl Node. . . . . . . . . . . . . . . . . . . . . . . . . . . . .1593-26 TP5000 MIB - Administration Node. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1593-27 TP5000 MIB - Radius Node. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160
3-28 TP5000 MIB - boardConfiguration Node . . . . . . . . . . . . . . . . . . . . . . . . . .1603-29 TP5000 MIB - Reboot Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1603-30 TP5000 MIB - imageActive Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1603-31 TP5000 MIB - cliUserTable Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1603-32 TP5000 MIB - snmpUserTable Node. . . . . . . . . . . . . . . . . . . . . . . . . . . . .1603-33 TP5000 MIB - snmpManagerTable Node . . . . . . . . . . . . . . . . . . . . . . . . .1613-34 TP5000 MIB - trapUserTable Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1613-35 TP5000 MIB - snmpv2CommunityTable Node. . . . . . . . . . . . . . . . . . . . . .1613-36 TP5000 MIB - alarmevent Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1614-1 Set IP-Mode Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1724-2 Set IP Command Hierarchy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .173
4-3 IOC Ethernet Ports Configured as Redundant Pair. . . . . . . . . . . . . . . . . .1744-4 Redundant IOC Cards with Redundant Ethernet Ports . . . . . . . . . . . . . . .1754-5 Redundant IOC Cards with Independent Ethernet Ports. . . . . . . . . . . . . .1764-6 Set Vlan Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1784-7 Set PTP Command Hierarchy - Common . . . . . . . . . . . . . . . . . . . . . . . . .1804-8 Set PTP Command Hierarchy - Common (contd). . . . . . . . . . . . . . . . . . .1804-9 Set PTP Command Hierarchy - Unicast Dynamic . . . . . . . . . . . . . . . . . . .1814-10 Set PTP Command Hierarchy - Unicast Static . . . . . . . . . . . . . . . . . . . . .1814-11 Set IO Command Hierarchy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1874-12 Set Input Command Hierarchy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1884-13 Set Output Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190
4-14 Set Output-10M Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1924-15 Set Output-PPS Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1934-16 Set Alarm-Config Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1964-17 Set SNMP Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2005-1 IOC1 and IOC2 Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2085-2 PTP Management Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2115-3 Client Status Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .213C-1 Locating the GPS Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285C-2 GPS Antenna Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289
-
8/11/2019 098-00028-000-rev-c TP5000
11/306
Tables
1-1 Serial Port Connector Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . .222-1 Management Ethernet Connector Pin Assignments . . . . . . . . . . . . . . . . . .372-2 Serial Port Connector Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . .37
2-3 Recommended and Supported SFP Transceivers . . . . . . . . . . . . . . . . . . .382-4 Installation Completeness Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .442-5 Module LED Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .453-1 IOC Clock Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1374-1 User Level and Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1664-2 Security Levels vs. RADIUS Server User-Name Attribute Settings. . . . . .1714-3 PTP - Common Parameter Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . .1824-4 PTP - Unicast Dynamic Parameter Descriptions . . . . . . . . . . . . . . . . . . . .1844-5 PTP - Unicast Static Parameter Descriptions . . . . . . . . . . . . . . . . . . . . . .1845-1 Force Unit to Send New TIme vs. Auto Sync. . . . . . . . . . . . . . . . . . . . . . .207
5-2 IOC Health Conditions That Can Cause Switchover . . . . . . . . . . . . . . . . .2096-1 Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2186-2 Troubleshooting Symptoms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2196-3 LED Conditions for the IOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2226-4 LED Conditions for the IMC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2266-5 Component Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2426-6 Connection Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2436-7 GPS Antenna Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2446-8 GPS Roof Mount Cables (spares and replacements only) . . . . . . . . . . . .244
A-1 System Notification Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250
A-2 Secondary Index Descriptions for System Notification Messages. . . . . . .261B-1 TimeProvider 5000 Mechanical Specifications . . . . . . . . . . . . . . . . . . . . .266B-2 TimeProvider 5000 Environmental Specifications . . . . . . . . . . . . . . . . . . .266B-3 TimeProvider 5000 Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . .267B-4 Serial Port Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .267B-5 LAN Port Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .267B-6 Input Signal Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268B-7 Output Signal Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268B-8 TimeProvider 5000 IOC Clock Specifications . . . . . . . . . . . . . . . . . . . . . .269B-9 General and Communication Parameters . . . . . . . . . . . . . . . . . . . . . . . . .270
B-10 GPS and Input Port Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272B-11 Output Port Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273B-12 PTP Grand Master Port IP Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . .273B-13 VLAN Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273B-14 Ethernet Link Auto-negotiation Parameters . . . . . . . . . . . . . . . . . . . . . . . .274B-15 PTP Grand Master Common Parameters . . . . . . . . . . . . . . . . . . . . . . . . .274B-16 PTP Grand Master Unicast Parameters . . . . . . . . . . . . . . . . . . . . . . . . . .275B-17 Telecom Output Port Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .275
-
8/11/2019 098-00028-000-rev-c TP5000
12/306
List of Tables
12 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
B-18 Telecom Input / Output Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .276B-19 GPS Port Alarm Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .276B-20 Announce Encoding Message vs. ToD Source and Clock Status . . . . . . .276C-1 GPS Antennas with Internal LNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .281C-2 Specifications for GPS Antennas with Internal LNA . . . . . . . . . . . . . . . . .281
C-3 26 dB L1 GPS Antenna Accessory Kit . . . . . . . . . . . . . . . . . . . . . . . . . . .282C-4 FCC-250B-90-1.5NFNF Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . .282C-5 GPS L1 Inline Amplifier Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . .283C-6 Antenna Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .284
-
8/11/2019 098-00028-000-rev-c TP5000
13/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 13
How to Use This Guide
This section describes the format, layout, and purpose of this guide.
In This Preface
Purpose of This Guide
Who Should Read This Guide
Structure of This Guide
Conventions Used in This Guide
Warnings, Cautions, Recommendations, and Notes
Related Documents and Information
Where to Find Answers to Product and Document Questions
Whats New In This Guide
-
8/11/2019 098-00028-000-rev-c TP5000
14/306
14 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
How to Use This GuidePurpose of This Guide
Purpose of This Guide
The TimeProvider 5000 Users Guidedescribes the procedures for unpacking,installing, using, maintaining, and troubleshooting the Symmetricom TimeProvider5000 Precision Timing Protocol Grand Master (TimeProvider 5000). It also includesappendixes that describe alarms and events, the languages that you use tocommunicate with the TimeProvider 5000, default values, and other information.
Who Should Read This Guide
Chapter 1, Overview, is written for non-technical audiences who need generalinformation about the product. Subsequent chapters contain technical informationabout the product. Other chapters and appendixes describe installation,maintenance, and configuration instructions or details primarily intended forqualified maintenance personnel.
This Users Guide is designed for the following categories of users:
Systems Engineers Chapter 1provides an introduction to the TimeProvider5000. Cross-references in this chapter direct you to detailed system informationin other chapters as appropriate.
Installation Engineers Chapter 2through Chapter 6and the appendixesprovide detailed information and procedures to ensure proper installation,operation, configuration, and testing of the TimeProvider 5000.
Maintenance Engineers Chapter 6and the appendicesprovide preventive
and corrective maintenance guidelines, as well as procedures for diagnosing andtroubleshooting fault indications and alarms.
Chapter 1is written for non-technical audiences who need information about theTimeProvider 5000 system. Chapters 2 through 6 contain detailed information andinstructions which are intended to be performed by qualifiedpersonnelonly.
-
8/11/2019 098-00028-000-rev-c TP5000
15/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 15
How to Use This GuideStructure of This Guide
Structure of This Guide
This guide contains the following sections and appendixes:
Chapter, Title DescriptionChapter 1, Overview Provides an overview of the product, describes the major
hardware and software features, and lists the systemspecifications.
Chapter 2, Installing Contains procedures for unpacking and installing the system, andfor powering up the unit.
Chapter 3, CLI Commands andSNMP
Describes the CLI command conventions, functions, and featuresand the SNMP protocol option.
Chapter 4, Provisioning Describes the commands and procedures required to provision theTimeProvider 5000 after installing the unit.
Chapter 5, Operating Provides basic information and procedures for proper systemoperation, including PTP Management.
Chapter 6, Maintenance andTroubleshooting
Contains preventive and corrective maintenance, andtroubleshooting procedures for the product. Also contains partnumber and ordering information and procedures for returning theTP5000.
Appendix A, System Messages Lists the alarms and events and provides basic indications of thesource of the alarm.
Appendix B, Specifications andFactory Defaults
Lists the specifications and factory defaults for the TimeProvider5000.
Appendix C, Installing the GPS
Antenna
Provides details about GPS Antenna kits and procedures for
installing the GPS antenna.Appendix D, Software Licenses Contains licensing information for third party software.
Index Provides references to individual topics within this guide.
-
8/11/2019 098-00028-000-rev-c TP5000
16/306
16 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
How to Use This GuideConventions Used in This Guide
Conventions Used in This Guide
This guide uses the following conventions:
Acronyms and Abbreviations Terms are spelled out the first time they appearin text. Thereafter, only the acronym or abbreviation is used.
Revision Control The title page lists the printing date and versions of theproduct this guide describes.
Typographical Conventions This guide uses the typographical conventionsdescribed in the table below.
When text appears
this way...... it means:
TimeProvider 5000 UsersGuide
The title of a document.
CRITICAL An operating mode, alarm state, status, or chassis label.
Select File, Open... Click the Open option on the File menu.
Press Enter
Press;
A named keyboard key.
The key name is shown as it appears on the keyboard.An explanation of the keys acronym or functionimmediately follows the first reference to the key, ifrequired.
User name: Text in a source file or a system prompt or other text thatappears on a screen.
pi ngst at us
A command you enter at a system prompt or text youenter in response to a program prompt. You must entercommands for case-sensitive operating systems exactlyas shown.
qualified personnel A word or term being emphasized.
Symmetricomdoes notrecommend...
A word or term given special emphasis.
-
8/11/2019 098-00028-000-rev-c TP5000
17/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 17
How to Use This GuideWarnings, Cautions, Recommendations, and Notes
Warnings, Cautions, Recommendations, and Notes
Warnings, Cautions, Recommendations, and Notes attract attention to essential orcritical information in this guide. The types of information included in each areexplained in the following examples.
Warning:To avoid serious personal injury or death, do not disregardwarnings. All warnings use this symbol. Warnings are installation,operation, or maintenance procedures, practices, or statements, thatif not strictly observed, may result in serious personal injury or evendeath.
Caution:To avoid personal injury, do notdisregard cautions. Allcautions use this symbol. Cautions are installation, operation, ormaintenance procedures, practices, conditions, or statements, that if
not strictly observed, may result in damage to, or destruction of, theequipment. Cautions are also used to indicate a long-term healthhazard.
ESD Caution:To avoid personal injury and electrostatic discharge(ESD) damage to equipment, do notdisregard ESD cautions. All ESDcautions use this symbol. ESD cautions are installation, operation, ormaintenance procedures, practices, conditions, or statements that ifnot strictly observed, may result in possible personal injury,electrostatic discharge damage to, or destruction of, static-sensitivecomponents of the equipment.
Electrical Shock Caution:To avoid electrical shock and possiblepersonal injury, do not disregard electrical shock cautions. Allelectrical shock cautions use this symbol. Electrical shock cautionsare practices, procedures, or statements, that if not strictly observed,may result in possible personal injury, electrical shock damage to, ordestruction of components of the equipment.
Recommendation:All recommendations use this symbol.Recommendations indicate manufacturer-tested methods or knownfunctionality. Recommendations contain installation, operation, or
maintenance procedures, practices, conditions, or statements, thatprovide important information for optimum performance results.
Note:All notes use this symbol. Notes contain installation, operation,or maintenance procedures, practices, conditions, or statements, thatalert you to important information, which may make your task easieror increase your understanding.
-
8/11/2019 098-00028-000-rev-c TP5000
18/306
18 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
How to Use This GuideRelated Documents and Information
Related Documents and Information
See your Symmetricom representative or sales office for a complete list of availabledocumentation.
Where to Find Answers to Product and Document
Questions
For additional information about the products described in this guide, please contactyour Symmetricom representative or your local sales office. You can also contact uson the web at www.symmetricom.com.
Whats New In This Guide
The following corrections and additions have been made to the TimeProvider UsersGuide:
Added descriptions and procedures for Redundant Ethernet Portsand redundant
IOC cards in Chapter 4, Provisioning. Added Provisioning the Programmable E1 Outputsto Chapter 4, Provisioning.
Added Managing PTP Clientssection to Chapter 5, Operating
Revised and expanded Upgrading the Firmwaresection to add examples, notesand corrections.
Revised and expanded Provisioninginformation, and moved from Ch. 5 to Ch. 4.
Revised and expanded Operatinginformation, and moved from Ch. 4 to Ch. 5.
Expanded Troubleshootingwith symptoms and corrective actions in Chapter 6,Maintenance and Troubleshooting
Deleted Chapter 2 Part Number and Ordering Information. Moved part numberinformation to Chapter 6, Maintenance and Troubleshooting
Moved descriptions of CLI commands from Appendix B: Command DescriptionsChapter 3, CLI Commands and SNMP.
Revised format of descriptions for CLI commands, with additional examples.
Note: Symmetricom offers training courses designed to enhance yourknowledge of the TimeProvider 5000. Contact your localrepresentative or sales office for a complete list of courses andoutlines.
http://www.symmetricom.com/http://www.symmetricom.com/ -
8/11/2019 098-00028-000-rev-c TP5000
19/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 19
Chapter 1 Overview
This chapter provides introductory information for the TimeProvider 5000.
In This Chapter
Overview
TimeProvider 5000 Connections
Physical Description
Functional Description
Configuration Management
Alarms
-
8/11/2019 098-00028-000-rev-c TP5000
20/306
20 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 1 OverviewOverview
Overview
The TimeProvider 5000 is a Next Generation Network (NGN) packet-based timingand frequency device that combines the functionality of a highly-accurate, IEEE1588 v2 Grand Master Clock with T1/E1 and 1PPS/10MHz I/O ports. TheTimeProvider 5000, available with either a Quartz or Rubidium oscillator,incorporates hardware-based time stamping to provide the highest level of timingand frequency accuracy over a broad range of wireline and wireless application.
The TimeProvider 5000 features are as follows:
Compact 1 RU Footprint
ETSI Compliant: Front Access for all Connectors
Dual 48 VDC Power Connectors
2 UTI Ports (future capability)
Up to 2 Legacy Inputs (T1 is a future capability)
Up to 4 Legacy Outputs (T1 is a future capability)
2 SFP Connectors on each IOC
1 L1 GPS Input on the IMC
1 Ethernet Mgmt Port on the IMC
1 EIA-232 Serial (Craft) Port on the IMC
LED indicators on the IOC and IMC
Hardware Protected
CLI and SNMP Management
-
8/11/2019 098-00028-000-rev-c TP5000
21/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 21
Chapter 1 OverviewTimeProvider 5000 Connections
TimeProvider 5000 Connections
Figure 1-1is a front view of the TimeProvider 5000 showing connectors and LEDs.Connections for the GPS input signal, Ethernet Management, and EIA-232 serialconnection are located on the IMC module. Small Form-factor Pluggable (SFP)connectors are located on the IOC modules. UTI, E1 or 10 MHz/1pps, and I/O portsare located on the I/O module. The 1PPS/10MHz ports are optional. Customers canorder units with either two E1 I/O ports and two E1 Outputs, or with two E1 I/O portsand 10MHz and 1PPS ports.
Figure 1-1. TimeProvider 5000 Connectors and LEDs
UTI Input and Output Connections
The UTI connectors are for future use.
Communications Connections
The IMC allows user control of the TimeProvider 5000 through either the EthernetManagement port or the EIA-232 serial port.
Ethernet Management Port
The Ethernet Management port is standard 10/100Base-T shielded RJ-45receptacle. To connect the TimeProvider 5000 to an Ethernet network, use ashielded twisted pair Ethernet RJ-45 cable.
EIA-232 Serial (Craft) Port
The EIA-232 serial port connection is made through a EIA-23 female connector onthe IMC. This port allow you to connect to a terminal or computer using a terminalemulation software package. When connecting to this port, use a shielded EIA-232direct connect cable.
-
8/11/2019 098-00028-000-rev-c TP5000
22/306
22 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 1 OverviewTimeProvider 5000 Connections
Figure 1-2shows the EIA-232 male connector pin assignments for the serial port.
Figure 1-2. Serial Port Male Connector Pins
Table 1-1describes the EIA-232 connector pin assignments for the serial port.
Output Connections
Programmable E1 Output Connections
Two of the four traditional telecom synchronization mini-BNC ports (Port1 andPort2) on the I/O module (Figure 1-3) are software configurable as E1 output ports,with the following signal types:
2.048 Mb/s (G.703/9)
2.048 MHz (G.703/13)
E1 Output Connections
Two of the four traditional telecom synchronization mini-BNC ports (Port3 andPort4) on the I/O module (Figure 1-3) are dedicated E1 output ports, with thefollowing signal types:
2.048 Mb/s (G.703/9)
2.048 MHz (G.703/13)
10MHz & 1PPS Output Connections
The I/O module is also available with 1PPS and 10MHz dedicated output portsinstead of the dedicated E1 output ports. See Figure 1-3.
Table 1-1. Serial Port Connector Pin Assignments
Signal Pin
TXD (Received Data) 2
RXD (Transmitted Data) 3Ground 5
-
8/11/2019 098-00028-000-rev-c TP5000
23/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 23
Chapter 1 OverviewTimeProvider 5000 Connections
Figure 1-3. I/O Module
PTP Output Connections
The TimeProvider 5000 provides two Ethernet 100/1000 Small-form FactorPluggable (SFP) connections on each IOC (see Figure 1-3) module. In PTP (IEEE1588v2) grand-master mode, the TimeProvider 5000 supports many slaves persystem in unicast mode. The TimeProvider 5000 will also support multi-cast mode(a future capability).
Figure 1-4. PTP Output Connections
Note:Units that provide 1PPS and 10MHz outputs must beordered from the factory; they cannot be reconfigured in thefield. One port provides 1PPS output and one port provides10 MHz output.
Notes:The UTI connectors in Figure 1-3are for future use.
-
8/11/2019 098-00028-000-rev-c TP5000
24/306
24 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 1 OverviewTimeProvider 5000 Connections
Input Connections
E1 Input Connections
Mini-BNC ports 1 and 2 on the I/O module (see Figure 1-3) are softwareconfigurable as traditional telecom input ports with the following signal types:
2.048 Mb/s (G.703/9)
2.048 MHz (G.703/13)
GPS Connection
The IMC has a GPS input to provide a frequency and time reference (see Figure1-5).
Figure 1-5. GPS Connection
Power and Ground Connections
The TimeProvider 5000 uses 48 VDC power and is not equipped with a Powerswitch; DC power is controlled by a power distribution panel connected to the powerconnectors. Frame ground connections are made on the grounding stud located on
the left side of the front panel, as identified with the international Ground marking,as shown in Figure 1-6.
Warning:To avoid serious personal injury or death, exercise cautionwhen working near high voltage lines and follow local buildingelectrical codes for grounding the chassis.
-
8/11/2019 098-00028-000-rev-c TP5000
25/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 25
Chapter 1 OverviewPhysical Description
Figure 1-6. Power and Ground
Physical Description
The TimeProvider 5000 consists of a 19-inch (48 cm) rack mount chassis, plug-inmodules, and hardware.
The TimeProvider 5000 has one I/O module slot, two IOC module slots, and oneIMC module slot. The grounding lug is located near the I/O module and the powersupply connectors are located on both sides of the chassis (see Figure 1-7). The
minimum configuration is an I/O module, an IOC module, and an IMC module. Thesecond IOC module slot is available for redundancy. See TimeProvider 5000 PartNumbers, on page 242.
Figure 1-7. TimeProvider 5000 Modules and Power Connections
Note:The TimeProvider 5000comes equipped with 19-inch rackmounting brackets. 23-inch (58.42 cm) rack mounting adapters arealso available as a separately ordered item. 21-inch (ETSI) rackmounting adapters are available as a separately ordered item.
-
8/11/2019 098-00028-000-rev-c TP5000
26/306
-
8/11/2019 098-00028-000-rev-c TP5000
27/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 27
Chapter 1 OverviewFunctional Description
Communication Ports
Communications ports on the IMC allow you to provision, monitor, and troubleshootthe chassis. You can communicate with the TimeProvider 5000 using either CLI orSNMP protocols.
Local Craft Serial Port
The EIA-232 port supports local control; you can configure the TimeProvider 5000with CLI commands using a terminal or computer with terminal emulation software.The connector is located on the IMC module. The Local port is configured as a DCEinterface and the default settings are as follows:
Baud = 57.6K
Data Bits = 8 bits
Parity = None
Stop bits = 1
Flow Control, None
Management Ethernet Port
The Management Ethernet connector provides connectivity to an Ethernet localarea network. Each Ethernet port has a unique internet protocol (IP) address andonce the IP address is set and a connection is made to a LAN, you can access theTimeProvider 5000.
Synchronization and Timing Inputs
The TimeProvider 5000 can use either GPS or E1 signals as external inputreferences. The GPS reference connects to a SMA connector on the IMC card andthe E1 inputs are configurable ports located on the I/O module.
Synchronization and Timing Outputs
The TimeProvider 5000 has four GbE Precision Timing Protocol (PTP) timingoutputs (2 per IOC card).
System Inputs and Outputs
The TimeProvider 5000 has two mini-BNC ports on the I/O module that are softwareconfigurable as either input or output ports. They can provide or receive thefollowing signal types:
Note:The SNMP feature can either be ordered in a new system, oradded to a previously ordered system as a field upgrade (see Table6-5for part number). Contact your Symmetricom representative formore information.
-
8/11/2019 098-00028-000-rev-c TP5000
28/306
28 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 1 OverviewConfiguration Management
2.048 Mb/s (G.703/9)
2.048 MHz (G.703/13)
The I/O module also has two mini-BNC ports that are dedicated output ports withthe following signal types:
2.048 Mb/s (G.703/9)
2.048 MHz (G.703/13)
1PPS/10 MHz (optional)
Configuration Management
The Command Line Interface (CLI), also called the ASCII command set, can beused to control the TimeProvider 5000 from a terminal connected to the EIA-232serial port, or the Ethernet port. Refer to Chapter 3, CLI Commands and SNMPforfurther details.
Alarms
The TimeProvider 5000 uses alarms to notify you when certain conditions aredeteriorating below specified levels. These alarms are indicated by module statusLEDs and by SNMP traps. You can provision the alarm to either be enabled ordisabled and the current alarm state can be obtained via the communication ports.For more information, see Provisioning Alarms, on page 195andAppendix A,System Messages.
Note:Units that provide 1PPS/10MHz output must beconfigured at the factory when ordered; they cannot bereconfigured in the field. One port provides 1PPS output andone port provides 10MHz output.
Note:Before you can communicate with the TimeProvider 5000through an Ethernet connection, you must first configure the Ethernetport using the serial connection (see Provisioning the Ethernet Ports,
on page 172).
-
8/11/2019 098-00028-000-rev-c TP5000
29/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 29
Chapter 2 Installing
This chapter describes the procedures for installing the TimeProvider 5000.
In This Chapter
Getting Started
Unpacking the Unit
Rack Mounting the Chassis
Working With Modules
Signal Connections
Connecting the GPS Antenna
Making Ground and Power Connections
Installation Check List
Applying Power to the TimeProvider 5000
-
8/11/2019 098-00028-000-rev-c TP5000
30/306
30 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 2 InstallingGetting Started
Getting Started
Before you begin to install the TimeProvider 5000, review the information in thissection.
If you encounter any difficulties during the installation process, contactSymmetricom Global Services (SGS). See Obtaining Technical Assistance, on page233for telephone numbers. Contact SGS - Product Technical Support for technicalinformation. Contact Customer Service for information about your order, RMAs, andother information.
Site Survey
Before you begin installation, determine the chassis location, ensure theappropriate power source is available (48 VDC), and ensure that the equipmentrack is properly grounded.
The TimeProvider 5000 is designed to mount in a 19-inch (48 cm) rack, occupies1.75 in (4.5 cm, 1 RU) of vertical rack space, and has a depth of 18 in (45.7 cm)..
The TimeProvider 5000 is to be installed into a rack with permanent connection tothe -48VDC mains. This connection is to be made to a branch over-current,short-circuit protection device with replaceable fusing of 5 amps, maximum. Forpermanently connected equipment a readily accessible disconnect device shall beincorporated in the building installation wiring.
Environmental Requirements
To prevent the unit from malfunctioning or interfering with other equipment, installand operate the unit according to the following guidelines:
Operating temperature: 23 Fto 113 F (5C to 45 C) Operating Humidity: 5% to 85% RH non-condensing
Use only shielded cable for all signal wiring, including I/O, clocks and Ethernet.Ground appropriately at both ends, or as required by local standards.
Note: 1RU above the TimeProvider 5000 must be leftunoccupied for heat dissipation
Note:23-inch (58.42 cm) rack mounting adapters are also availableas a separately ordered item. 21-inch (ETSI) rack mounting adaptersare available as a separately ordered item.
-
8/11/2019 098-00028-000-rev-c TP5000
31/306
-
8/11/2019 098-00028-000-rev-c TP5000
32/306
32 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 2 InstallingUnpacking the Unit
1. Wear a properly grounded protective wrist strap or other ESD device.
2. Inspect the container for signs of damage. If the container appears to bedamaged, notify both the carrier and your Symmetricom distributor. Retain theshipping container and packing material for the carrier to inspect.
3. Open the container, being careful to cut only the packaging tape.
4. Locate and set aside the CD, printed information, and paperwork that is includedin the container.
5. Remove the unit from the container and place it on an anti-static surface.
6. Locate and set aside small parts which may be packed in the container.
7. Remove the accessories from the container.
8. Remove the anti-static packaging from the unit and accessories.
9. Verify that the model and item number shown on the shipping list agrees with themodel and item number on the equipment. The item number can be found on alabel affixed to the top of the unit, front and center. See Figure 2-1for the locationof the label. Contact your Symmetricom distributor if the model or item number donot match.
For a complete listing of item numbers, see Table E-1and Table E-3.
Figure 2-1. Location of Product Label
http://e%20part%20numbers.pdf/http://e%20part%20numbers.pdf/http://e%20part%20numbers.pdf/http://e%20part%20numbers.pdf/ -
8/11/2019 098-00028-000-rev-c TP5000
33/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 33
Chapter 2 InstallingRack Mounting the Chassis
Rack Mounting the Chassis
The installation procedure described in this section provides general guidelines forinstalling the TimeProvider 5000. Always follow applicable local electrical standards.
Use the following steps to mount the TimeProvider 5000 in a rack.
1. TimeProvider 5000 is shipped with rack mounting brackets attached. The rackmounting brackets can be removed and reattached in a different orientation, ifdesired. See Figure 2-2for mounting hole placements. See Figure 2-3andFigure 2-4for chassis dimensions. Ensure that the mounting bracketson bothsides are attached to the chassis at equal distances from the front of the unit (seeFigure 2-5) using 6-32 x 1/4-inch screws.
2. Mount the chassis to the front of the equipment rack rails with four screws andassociated hardware. Use the proper screws for the equipment rack.
Figure 2-2. Mounting Hole Placements
Figure 2-3. Chassis Dimensions Front View
Note:1RU above the TimeProvider 5000 must be leftunoccupied for heat dissipation.
Note:The TimeProvider 5000comes equipped with 19-inch rackmounting brackets. 23-inch (58.42 cm) rack mounting adapters arealso available as a separately ordered item. 21-inch (ETSI) rackmounting adapters are available as a separately ordered item.
-
8/11/2019 098-00028-000-rev-c TP5000
34/306
34 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 2 InstallingRack Mounting the Chassis
Figure 2-4. Chassis Dimensions Top View
Figure 2-5. Rack Mounting the TimeProvider 5000
-
8/11/2019 098-00028-000-rev-c TP5000
35/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 35
Chapter 2 InstallingWorking With Modules
Working With Modules
This section describes how to install, remove, and handle the modules associatedwith the TimeProvider 5000.
Handling Modules
When handling any of the modules, observe the following precautions:
1. Use proper static control precautions when handling modules! Protect theequipment against ESD (electrostatic discharge) by using a grounded protectivewrist strap and normal equipment grounding.
2. Avoid touching component leads and edge connectors.
3. Avoid placing the module on an ungrounded surface.
4. Avoid allowing the module to come in contact with insulated surfaces.
Inserting Modules
This procedure is common for all modules.
Use the following procedure to insert a module into the chassis:
1. Align the module edges within the guides of the selected slot.
2. Slide the module into the chassis and press firmly until it seats fully into itsbackplane edge connector.
3. Tighten the captive screws located on each side of the panel.
Caution:All modules can be removed and inserted while system
power is supplied without damaging modules; however, systemperformance may be affected.
Note:The I/O card does not have captive screws and requires aPhillips screwdriver.
Caution: To avoid possible damage or intermittent failures, ensurethat you have completely inserted the module into the chassis andthat you have securely tightened the captive screws.
-
8/11/2019 098-00028-000-rev-c TP5000
36/306
36 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 2 InstallingSignal Connections
Removing Modules
To remove a module, loosen the screws and then pull out the module. Be sure toplace the module on a static-free surface.
Signal Connections
The connectors for the GPS input signal, Ethernet Management, and EIA-232 serialconnection are located on the IMC module. The PTP output connectors are locatedon the IOC module. The E1 and UTI connectors are located on the I/O module.
Communications Connections
The IMC allows user control of the TimeProvider 5000. The EIA-232 serial port andEthernet Management port are located on the IMC as shown in Figure 2-6. See
Working With Modules, on page 35for module installation instructions.
Figure 2-6. IMC Module
Ethernet Management PortThe Ethernet Management port is standard 10/100Base-T shielded RJ-45receptacle. To connect the TimeProvider 5000 to an Ethernet network, use ashielded twisted pair Ethernet RJ-45 cable.
Caution:You must disconnect the GPS antenna before removing theIMC module.
Note: The UTI connectors are for future use.
-
8/11/2019 098-00028-000-rev-c TP5000
37/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 37
Chapter 2 InstallingSignal Connections
The connector pinouts are listed in Table 2-1.
EIA-232 Serial (Craft) Port
The EIA-232 serial port connection is made through a EIA-232 female connector onthe IMC. This ports allow you to connect to a terminal or computer using a terminalemulation software package for remote monitoring and control. When connecting tothis port, use a shielded EIA-232 direct connect cable.
Figure 2-7shows the EIA-232 male connector pin assignments for the serial port.
Figure 2-7. Serial Port Male Connector Pins
Table 2-2describes the EIA-232 connector pin assignments for the serial port.
Table 2-1. Management Ethernet Connector Pin Assignments
Signal Name Pin
TX+ (Transmit positive) 1
TX- (Transmit negative) 2
RX- (Receive negative) 3
RX+ (Receive positive) 6
Not Used 4, 5, 7, 8
Table 2-2. Serial Port Connector Pin Assignments
Signal Pin
TXD (Received Data) 2
RXD (Transmitted Data) 3
Ground 5
-
8/11/2019 098-00028-000-rev-c TP5000
38/306
38 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 2 InstallingSignal Connections
Synchronization and Timing Connections
The TimeProvider 5000 has one GPS input on the IMC module, two redundant PTPtiming outputs on each IOC module, and four E1/T1 connections on the I/O module.Two of the four E1/T1 connectors can be outputs, or inputs.
GPS Connections
To connect a GPS signal, you must install a GPS antenna. See Connecting the GPSAntenna, on page 40. Also see Working With Modules, on page 35for moduleinstallation instructions.
PTP Connections
The two Ethernet 10/100/1000 Small-form Factor Pluggable (SFP) connections oneach IOC provide redundant PTP outputs. See Figure 2-8.
Figure 2-8. PTP Output Connections
Only the SFP transceivers in Table 2-3are recommended and supported. OtherSFP transceivers are not supported and may cause the TimeProvider 5000 to notcomply with regulatory requirements.
Caution:The GPS cable should only be connected while the unit isproperly Earth grounded.
Table 2-3. Recommended and Supported SFP Transceivers
Type Transceiver
Optical 1000 Base-SX Multi-Mode Ethernet 850nm(Symmetricom 121-20621-11-2)
Avago AFBR-5710PZ
Finisar FTLF8519P2BNL
Optical 1000 Base-LX Single-Mode Ethernet 1310nm(Symmetricom 121-20621-10-2)
Avago AFCT-5701PZ
Finisar FTLF1319P1BTL
RJ45 100/1000/1GbE Base-T Full-Duplex(Symmetricom 121-20621-13-2)
Avago ABCU-5710RZ
-
8/11/2019 098-00028-000-rev-c TP5000
39/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 39
Chapter 2 InstallingSignal Connections
E1 Connections
Two of the four traditional telecom synchronization mini-BNC ports (Port1 andPort2) on the I/O module (see Figure 2-9) are software configurable as E1 input oroutput ports, with the following signal types:
2.048 Mb/s (G.703/9)
2.048 MHz (G.703/13)
Two of the four traditional telecom synchronization mini-BNC ports (Port3 andPort4) on the I/O module (Figure 2-9) are dedicated E1 output ports, with the
following signal types:
2.048 Mb/s (G.703/9)
2.048 MHz (G.703/13)
The I/O module is also available with 1PPS and 10MHz dedicated output portsinstead of the dedicated E1 output ports. See Figure 2-9.
Figure 2-9. E1 Output Connections
Note:Amphenol mini-BNC connectors (031-70261) can beused to create cables. Alternatively, Symmetricom sells a kit of4 mini-BNC to BNC adapter cables (093-00068-000).
Note:Units that provide 1PPS and10MHz outputs must beordered from the factory; they cannot be reconfigured in thefield. One port provides 1PPS output and one port provides
10 MHz output.
-
8/11/2019 098-00028-000-rev-c TP5000
40/306
-
8/11/2019 098-00028-000-rev-c TP5000
41/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 41
Chapter 2 InstallingMaking Ground and Power Connections
Ground Connections
Frame ground connections are made using the M4 Grounding Terminal Studlocated on the left side of the front panel of the unit. This stud is marked with theuniversal ground symbol, as shown in Figure 2-11.
Figure 2-10. TimeProvider 5000 Power Connections
Figure 2-11. Universal Ground Symbol
After installing the TimeProvider 5000 into the rack, connect the chassis to theproper grounding zone or master ground bar. Run a 16 AWG green/yellow-stripedinsulated wire from the TimeProvider 5000 grounding terminal to the Earth Groundon the rack. The rack grounding method is below.
1. Crimp the customer-supplied UL listed Ring Lug to one end of the 16 AWG wireand connect it to the ground terminal on the left side of the front panel using thesupplied M4 Kept machine nut. The surface of the TimeProvider 5000 Earthgrounding terminal must be clean of contaminants and oxidation.
2. Crimp the appropriate customer-supplied UL listed Ring Lug to the other end ofthe 1 mm / 16 AWG green/yellow-striped wire. Remove the paint and sand thearea around the screw hole to ensure the proper conductivity. Coat theconnection with an electrically conductive antioxidant compound such asKopr-shield spray. Connect this Ring Lug to the rack with appropriate customersupplied screws and external star lock washers.
3. Using a digital voltmeter, measure between the ground and chassis and verifythat no voltage exists between them.
Recommendation:Although there are a number of methods forconnecting the equipment to earth ground, Symmetricomrecommends running a cable of the shortest possible length from theground lug to earth ground.
-
8/11/2019 098-00028-000-rev-c TP5000
42/306
42 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 2 InstallingMaking Ground and Power Connections
Power Connections
Use the following procedure to make the power connections:
1. Ensure the power source is turned off.
2. Connect the frame ground terminal to earth ground.
3. Locate the power connectors included in the installation kit, Phoenix Contact p/nMC 1,5/2-STF-3,81.
4. Using 1 mm / 18 AWG (minimum) stranded wire, connect primary power to theconnectors per the polarity markings. Use the polarity markings of "-48V" and"RTN" as a reference for the proper polarity connection..
5. Insert the connectors into the power connections in the chassis. SeeFigure 2-12. Tighten screws in the connector
Figure 2-12. TimeProvider 5000 Power Connector
Warning: To avoid possible damage to equipment, you must provide
power source protective fusing as part of the installation. TheTimeProvider 5000 is intended for installation in a restricted-accesslocation.
Caution:To avoid damage to the unit, remove the fuses in the fusepanel which provides power to the TimeProvider 5000 before makingpower connections.
Note: The -48VDC power must be connected with the proper polarity.The unit will not be damaged by reverse polarity, but the unit will notoperate if the polarity is reversed.
-
8/11/2019 098-00028-000-rev-c TP5000
43/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 43
Chapter 2 InstallingMaking Ground and Power Connections
Testing Power Connections
To verify that the power connections to the TimeProvider 5000 are correct, followthe steps in this section. The connections on the primary power module are referredto as Power A and Return A. The connections on the secondary power module arereferred to as Power B and Return B. Use a digital multimeter (Fluke 77 orequivalent) to make the measurements.
1. Remove all fuses that supply power to the unit from the fuse panel.
2. Ensure that no IOC or IMC modules are installed in the unit.
3. Disconnect the -48V battery leads from the units power connector terminals. Seethe primary and secondary power connections in Figure 2-13. Leave the Returnbattery leads connected to the unit.
Figure 2-13. Power and Ground Connections on the TimeProvider 5000
4. At the chassis end of the battery leads, use the multimeter to measure thevoltage between the following test points:
Test Point Test Point ResultBattery A lead Battery B lead 0 VBattery A lead Primary: Return A 0 VBattery A lead Earth Ground 0 VBattery B lead Secondary: Return B 0 VBattery B lead Earth Ground 0 V
5. Reconnect the48V battery A and battery B leads to the48V A and48V Bterminal connectors.
6. Install the A fuse in the power source fuse panel.
7. Measure the voltage between the48V A and Return terminals on the primarypower module. The multimeter should indicate 42 VDC to 56 VDC.
8. Install the B fuse in the power source fuse panel.
9. Measure the voltage between the48V B and Return terminals on the secondarypower module. The multimeter should indicate 42 VDC to 56 VDC.
-
8/11/2019 098-00028-000-rev-c TP5000
44/306
44 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 2 InstallingInstallation Check List
The unit is now powered up.
Installation Check List
To verify that the installation of the TimeProvider 5000 is complete, perform thechecks and procedures in Table 2-4.
Applying Power to the TimeProvider 5000
The TimeProvider 5000 is not equipped with a Power switch. DC power is controlledby a power distribution panel. After installing the unit in a rack and making thenecessary connections described in previous sections, turn on power at thedistribution panel.
Normal Power Up Indications
As the TimeProvider 5000 powers up and begins normal operation, the IOC moduleand IMC module LEDs all turn on. After the module self-test is complete and themodule firmware is operational, the LED states may change to indicate theappropriate state or status.
Table 2-5provides a description of the module LEDs.
Table 2-4. Installation Completeness Checklist
Operation Complete
Ensure the TimeProvider 5000 chassis is securely attached to mounting rack
Ensure that the appropriate modules (and filler panels if needed) are installed
Verify that all power and ground wires are installed correctly and securely
Verify that all communications cables are properly installed
Verify that all input and output cables are properly installed
-
8/11/2019 098-00028-000-rev-c TP5000
45/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 45
Chapter 2 InstallingApplying Power to the TimeProvider 5000
Table 2-5. Module LED Descriptions
LED Label Description
IMC Module
PowerModule Power Indicator
PWR Green- Module power availableOff- Module power not available
-48V A-Bus
A-Bus Battery Indicator
BT A Off- A-Bus power OK
Red- A-Bus power failed
-48V B-Bus
B-Bus Battery Indicator
BT B Off- B-Bus power OK
Red- B-Bus power failed
System Health
Aggregation of system alarms
indicator
SYS Off- System operating normally
Amber- System operational Minor Alarm(s)
Red- System operational Major or Critical Alarm(s)
IMC Alarm
IMC module alarm/fault indicator
ALM Off- IMC operating normally
Amber- IMC operational Minor Alarm(s)
Red- IMC operational Major/Critical Alarm(s)
Flashing Green- Software starting up
GPS Status
GPS engine status indicator
GPS Green- GPS enabled and GPS engine/interface isoperating normally
Amber- GPS enabled and GPS engine or antennainterface has operational issues
Off- GPS disabled
Ethernet Management PortLEDs on the Ethernet connector
MGMT Left Amber Flash- ActivityLeft Off- No Activity
Right Green- Link has been established
Right Off- Link has not been established
IOC Module
Power
Module Power Indicator
PWR Green- Module power available
Off- Module power not available
Active
Indicates which IOC is responsiblefor generating PTP, Telecom,
10MHz, and 1PPS outputs
ACT Off- Standby IOC or System Startup
Green- Active IOC
IOC Alarm
IOC module alarm/fault indicator
ALM Off- IOC operating normally
Amber- IOC operational Minor Alarm(s)
Red- IOC has Failed or has Major/Critical Alarm(s)
Flashing Green- Software starting up
-
8/11/2019 098-00028-000-rev-c TP5000
46/306
46 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 2 InstallingApplying Power to the TimeProvider 5000
Ethernet Port 1
ETH1 link/activity indicator
ETH1 Green- Link has been established
Flashing Green- Link activity
Off- Link has not been established
Ethernet Port 2
ETH2 port link/activity indicator
ETH2 Green- Link has been established
Flashing Green- Link activity
Off- Link has not been established
Local Oscillator State
Indicates the current mode ofoperation of the LO servo
HOLD Off- Oscillator is operating in Locked mode
Amber- Oscillator is operating in Holdover orAcquire modes
Flashing Amber- Oscillator is operating inWarm-up mode
Table 2-5. Module LED Descriptions (Continued)
LED Label Description
-
8/11/2019 098-00028-000-rev-c TP5000
47/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 47
Chapter 3 CLI Commands and SNMP
This chapter describes the CLI command conventions, the prompts, line editingfunctions, and command syntax. The CLI command functions and features areorganized by user security access levels and are listed alphabetically. This chapteralso describes the SNMP option.
In This Appendix
CLI Overview
TimeProvider 5000 CLI Command Set
Simple Network Management Protocol (SNMP)
-
8/11/2019 098-00028-000-rev-c TP5000
48/306
-
8/11/2019 098-00028-000-rev-c TP5000
49/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 49
Chapter 3CLI Overview
TimeProvider 5000 CLI Command Conventions
The following are conventions used for the TimeProvider 5000 CLI command set .
Commands are case sensitive
{ } Braces indicate more than one parameter data option. When enteringoptions in the CLI command, enter one option from those available within thebraces. Options within braces { } are separated by a pipe ( | ).
[ ] Brackets provide information about the allowed range. The first value is theminimum, and the last value is the maximum.
Boldhighlights keywords in the command syntax
Italicsindicate variable options.
CLI Command Keyboard Usage
You must press the SPACE key, and then press the TAB key after entering a CLIcommand. Also, after entering a command, you may see . This is aprompt for you to press ENTER to execute the command that you entered.
The interface has built-in features for navigating within the CLI commandhierarchy, which are as follows:
The TAB key can be used at any time while typing a command (including at theprompt) to provide continuation options. Press the TAB key to display a list of theavailable commands. Press the TAB key at any time while typing a command TimeProvider 5000 will respond with the completion of the keyword or availablecompletion choices based on the letters you typed.
The ?(SHIFT+QUESTION MARK) accesses the CLI online help. It can be usedat any time while typing a command (including at the prompt) to providecontinuation options. These options include brief descriptions of commands, ordata type, format, and range.
If typing of a keyword is partially complete, the completion will display if it isunique, otherwise, the completion choices will be available.
If the keyword is complete, and you press the TAB key or ? (SHIFT+QUESTIONMARK), the choices for the next syntax element will display.
In the following example, if you press the TAB key, or the ?(SHIFT+QUESTION MARK), after typing s, the CLI commands set ,
set - t i meout , show, and syncdisplay.Typing sat the prompt:
t p5000> s
Then pressing the TAB key :
set set - t i meout show sync
-
8/11/2019 098-00028-000-rev-c TP5000
50/306
50 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 3CLI Overview
Or pressing the ? ( SHI FT+QUESTI ON MARK) will display the availablecommands that start with s (for this example) and brief descriptions of thosecommands:
set - Set TP5000 i nf or mat i on or set t i ng
show -Di spl ay TP5000 i nf ormat i on or set t i ng
sync - Synchr oni ze t he TOD sour ce
set - t i meout - Set t he i nact i vi t y t i meout t o t he def i ned seconds
Previously typed commands can be recalled by using the UP ARROW key. Youcan recall up to five previously typed commands. Continually pressing the UPARROW key will cycle you through the five previously typed commands. Afterpressing the UP ARROW key five times, you will go back to the last commandyou previously typed. Use the DOWN ARROW key to cycle the five prior typed
commands in the opposite direction. You can use the BACKSPACE to correct keystroke errors, or to reuse parts of a
previously typed command. When using BACKSPACE, the removed characterswill still appear on the screen, but they have been removed to the position shownby the cursor. When you start typing, the removed characters are overwritten.
Command Line Format
The command line format is as follows:
[ Verb] Command [Paramet er ] [ Dat a] EOL
Verb- the type of action to be taken with the command.
Set- enables you to provision a defined parameter.
Show- enables you to display the provisioned state of a parameter.
Parameter- command input that defines the particular command element to beshown or modified.
Data- the data input for the parameter.
EOL- this parser responds only to . When the parser receives, the input is terminated, and the command line entry is processed.
For all commands that indicate a specific port on an IOC card, the port will bereferred to as IOC-[y] or IOC1-[y] in the command description, where y=1 or 2. Ifport redundancy is enabled, the bonded port will use the configuration for port 1(y=1) for all commands.
-
8/11/2019 098-00028-000-rev-c TP5000
51/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 51
Chapter 3TimeProvider 5000 CLI Command Set
Command User Levels
The TimeProvider 5000 provides a hierarchy of CLI command user levels thatpermit an increasing level of access to system parameters. This allows the systemadministrator to add users who can only view but not change system parametersand users who can view andchange system parameters.
The users assigned to each security level have access options available as follows:
Level 1 - user class, with read-only rights
Level 2 - config user class, with read-write rights
Level 3 - administrator user class, with read-write rights and can also configureusers and upgrade firmware
TimeProvider 5000 CLI Command Set
This section provides an alphabetical listing and details of all CLI commands.
show alarm
Displays the system's standing (active) alarms and events.
Command Syntax:
show {al arm | event }
Example:
t p5000> show al ar m
Response:
I D Mod Sever i t y Dat e- Ti me Descr i pt i ons- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -7 I OC Mi nor 2009- 06- 08 23: 38: 59 ETH2 Por t l i nk down
Remarks:The information displayed is expected to be identical to an entry in theEvent/Alarm Log File.
Level : User, Config, and Admin
-
8/11/2019 098-00028-000-rev-c TP5000
52/306
-
8/11/2019 098-00028-000-rev-c TP5000
53/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 53
Chapter 3TimeProvider 5000 CLI Command Set
To provision the Level of the specified Alarm number:
set al ar m- conf i g l evel {al ar m [ 0 t o 78] | al l } {2 | 3 | 4 | 5}
where
2 - Cr i t i cal
3 - Maj or4 - Mi nor5 - Event
To provision the reporting delay of the specified Alarm number in seconds:
set al ar m- conf i g del ay {al ar m [ 0 t o 78] | al l } [ 0 t o 500000]
Range: Delay - 0 to 500,000 seconds
Default: Delay - 0 seconds
Example 1:
To Disable alarm #35
t p5000> set al ar m- conf i g st ate al ar m 35 di sabl e
Example 2:
To set the level of alarm #31 to Error - major (3)
t p5000> set al ar m- conf i g l evel al ar m 31 3
Remarks:The severity level and delay of transitory events cannot be changed.
Level : Config and Admin only
-
8/11/2019 098-00028-000-rev-c TP5000
54/306
54 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 3TimeProvider 5000 CLI Command Set
alias
This command is used to assign an alias for a CLI command (or any characterstring). The alias can then be used as a convenient substitution for the CLIcommand to which it has been assigned.
The alias command can also be used to display all defined aliases and thecommands to which they have been assigned.
Command Syntax:
To assign an alias name to a command (or any portion of a command):
al i as
To display all defined aliases and the commands to which they have beenassigned:
al i as
Example 1:
To set the alias abc for the command show i p st at us i oc. The command stringmust be contained within double quote marks ()
t p5000> al i as abc show i p st atus i oc
Example 1a:
To use the alias abc to execute the command show i p stat us i oc
t p5000> abc
Response 1a:
ETH1 Li nk encap: Et her net HWaddr 00: B0: AE: 01: 32: 49
i net addr : 192. 168. 1. 11 Bcast : 192. 168. 1. 255 Mask: 255. 255. 255. 0
UP BROADCAST RUNNI NG MULTI CAST MTU: 1500 Met r i c: 1
RX packets: 0 err ors : 0 dr opped: 0 overr uns: 0 f r ame: 0
TX packet s: 32 err ors: 0 dr opped: 0 over r uns: 0 car r i er: 0
col l i si ons: 0 t xqueuel en: 1000
RX byt es: 0 ( 0. 0 B) TX bytes: 1920 ( 1. 8 Ki B)
ETH2 Li nk encap: Et her net HWaddr 00: B0: AE: 01: 32: 4A
i net addr : 192. 168. 2. 11 Bcast : 192. 168. 2. 255 Mask: 255. 255. 255. 0
-
8/11/2019 098-00028-000-rev-c TP5000
55/306
098-00028-000 Revision C October, 2009 TimeProvider 5000 Users Guide 55
Chapter 3TimeProvider 5000 CLI Command Set
UP BROADCAST RUNNI NG MULTI CAST MTU: 1500 Met r i c: 1
RX packets: 6 err ors : 0 dr opped: 0 overr uns: 0 f r ame: 0
TX packet s: 32 err ors: 0 dr opped: 0 over r uns: 0 car r i er: 0
col l i si ons: 0 t xqueuel en: 1000
RX byt es: 360 ( 360. 0 B) TX byt es: 1920 ( 1. 8 Ki B)
Example 2:
To display the aliases assigned for the TP5000
t p5000> al i as
Response 1:
al i as show i p st atus i oc=' ABC'
Level : User, Config, and Admin
-
8/11/2019 098-00028-000-rev-c TP5000
56/306
56 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 3TimeProvider 5000 CLI Command Set
show authentication
Displays how the system authenticates users.
If applicable, displays RADIUS server IP address or hostname and key.
Command Syntax:
show aut hent i cat i on
Example:
t p5000> show aut hent i cat i on
Response:
Aut hent i cat i on I nf o:
Radi us ser ver addr - 0. 0. 0. 0Radi us server key - noneRadi us ser ver st at e - di sabl e
Remarks:Authentication can be local or RADIUS
Level : Admin only
-
8/11/2019 098-00028-000-rev-c TP5000
57/306
-
8/11/2019 098-00028-000-rev-c TP5000
58/306
58 TimeProvider 5000 Users Guide 098-00028-000 Revision C October, 2009
Chapter 3TimeProvider 5000 CLI Command Set
show auto-sync
Displays the auto sync state
Command Syntax:
show aut o- sync
Example:
t p5000> show aut o- sync
Response:
AUTO- SYNC - enabl e
Level : User, Config, and Admin
set auto-sync
Provisions the auto sync IOC time to IMC time. This parameter is mainly used whenToD-Source is set for GPS mode and the IOC has passed the warm-up state. Whenauto sync is enabled, IOC time will be synchronized to IMC time if they are different.If auto sync is disabled and IOC time is different from IMC time, an alarm will begenerated. The user can then use the Sync TOD-Sourcenow command tomanually synchronize IOC time to IMC time.
Command Syntax:
set aut o- sync {enabl e