08 SEP-601 PCM 600 1p5 Disturbance Handling

download 08 SEP-601 PCM 600 1p5 Disturbance Handling

of 16

Transcript of 08 SEP-601 PCM 600 1p5 Disturbance Handling

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    1/16

    1

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    PCM 600Disturbance Handling

    Task Scheduler

    Substation Automation andProtection Training

    3

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Disturbance Handling

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    2/16

    4

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Disturbance Report Tool Disturbance Recordings List

    Read Recordings

    IED Recordings

    5

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Disturbance Report Tool Create the report

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    3/16

    6

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Disturbance Report Tool The report (default template)

    Total Recording (analog signals)

    Total Recording (binary signals)

    The Disturbance (Disturbance 1).

    Automatic Perturbation Detection

    Fault voltages for Disturbance 1

    Pre-fault voltages and currents for

    Disturbance 1

    7

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Disturbance Report Tool The Report (Default Template)

    TOTAL RECORDING

    Visualization of the full disturbance: analog and binary signals.

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    4/16

    8

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Automatic Disturbance Reporting

    Disturbance 1

    Automatic perturbation

    detection

    Automatic scaling

    around the

    perturbation

    Automatic visualization

    of binary signals related

    to the event

    Automatic estimation of

    fault quantities

    9

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Disturbance Report Tool The report (default template)

    The Disturbance (Disturbance 1)

    Estimated fault voltage

    (the time of calculation is

    indicated here)

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    5/16

    10

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Disturbance Report Tool The report (default template)

    The Disturbance (Disturbance 1)

    Estimated fault voltages and

    currents

    (the time of calculation is

    indicated here)

    11

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Disturbance Report Tool Several disturbances

    Disturbance 1 Disturbance 2 Disturbance 3

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    6/16

    12

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Disturbance Report Tool LDCM and derived signals

    Local and remote

    analog signals

    Derived signals

    Example: Line Differential Protection

    13

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Disturbance Recording Manual Analysis

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    7/16

    14

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Disturbance Recording 3rd part Comtrade Viewer

    Disturbance recorded in the IED

    Uploaded from IED

    Open with Test-Set Software

    Injected again in the IED (testing)

    15

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Disturbance Report Tool Import (Export) of disturbances

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    8/16

    16

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Disturbance Recording: Reading and e-mailing

    17

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Manage the Scheduler Add a Task

    OPEN THE SCHEDULER AND

    ADD A TASK..

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    9/16

    18

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Manage the Scheduler Schedule Task

    By adding a task you can

    decide its time scheduling

    (the task has not been

    defined yet).

    19

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Manage the Scheduler Define the Task

    DEFINE THE TASK

    (Add Object Jobs with DRAG &

    DROP)..

    And start to define the job:

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    10/16

    20

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Manage the Scheduler Define the Task

    For the moment only

    Disturbance Handling is

    available:

    It is then possible to choose to

    upload the disturbances from the IED (read new recordings)

    or to

    upload disturbances and send report by mail (read recordings and send

    report):

    21

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Manage the Scheduler Define the Task

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    11/16

    22

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Manage the Scheduler Enable the Task

    START THE TASK

    (Enable the Task)..

    23

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Manage the Scheduler Start the TaskSTART TASK

    MANAGER.

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    12/16

    24

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Read new Disturbance Recordings

    25

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Read Recordings and Distr ibute via e-mail

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    13/16

    26

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Disturbance Handling

    Define E-mail address and

    template for the report that

    will be sent.

    These data are defined under

    the Disturbance Handler, so you

    have to open it for your terminal:

    27

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Disturbance Handling Settings

    Right click on the

    Recordings part and

    choose settings:

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    14/16

    28

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Disturbance Handling Template

    Choose Create Report

    Open the General Tab and define the

    type of the template that will be generated

    and sent

    29

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Disturbance Handling e-mail

    Open the E-Mail tab and

    define the SMTP server,

    e-mail addresses etc..

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    15/16

    30

    ABB

    PowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Disturbance Handling Define the Task

    Define the e-mailing job

    31

    ABBPowerTechnologiesAB,

    2007

    2007-09-07 Substation Automation and Protection Training

    Scheduler Disturbance Handling Start the Task

    Start the Task

    Manager

  • 8/13/2019 08 SEP-601 PCM 600 1p5 Disturbance Handling

    16/16