066L124-IT-US-P01V02 rpt .|.s.| Secure Serial Device...

35
No.5-22, Ruei-Shu Valley, Ruei-Ping Tsuen Lin Kou Shiang, Taipei 244 Taiwan, R.O.C. TEL:+886-2-8601-3788 FAX:+886-2-8601-3789 Email:[email protected] http://www.quietek.com CERTIFICATE Issued Date: Jun. 26, 2006 Report No.: 066L124-IT-US-P01V02 This is to certify that the following designated product Product : Secure Serial Device Server Trade name : Moxa Model Number : NPort 6250, NPort 6250-M-SC, NPort 6250-S-SC Company Name : Moxa Technologies Co., Ltd. This product, which has been issued the test report listed as above in QuieTek Laboratory, is based on a single evaluation of one sample and confirmed to comply with the requirements of the following EMC standard. FCC CFR Title 47 Part 15 Subpart B: 2005 CISPR 22: 2005 ANSI C63.4: 2003 TEST LABORATORY George Chen / President

Transcript of 066L124-IT-US-P01V02 rpt .|.s.| Secure Serial Device...

No.5-22, Ruei-Shu Valley, Ruei-Ping Tsuen Lin Kou Shiang, Taipei 244 Taiwan, R.O.C. TEL:+886-2-8601-3788 FAX:+886-2-8601-3789 Email:[email protected] http://www.quietek.com

CERTIFICATE

Issued Date: Jun. 26, 2006

Report No.: 066L124-IT-US-P01V02

This is to certify that the following designated product

Product : Secure Serial Device Server

Trade name : Moxa

Model Number : NPort 6250, NPort 6250-M-SC, NPort 6250-S-SC

Company Name : Moxa Technologies Co., Ltd.

This product, which has been issued the test report listed as above in QuieTek

Laboratory, is based on a single evaluation of one sample and confirmed to

comply with the requirements of the following EMC standard.

FCC CFR Title 47 Part 15 Subpart B: 2005

CISPR 22: 2005

ANSI C63.4: 2003

TEST LABORATORY

George Chen / President

Test Report

Product Name : Secure Serial Device Server

Model No. : NPort 6250,NPort 6250-M-SC,NPort 6250-S-SC

Applicant : Moxa Technologies Co., Ltd

Address : Fl.4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien

City, Taipei, Taiwan, R.O.C.

Date of Receipt : 2006/06/14

Issued Date : 2006/06/26

Report No. : 066L124-IT-US-P01V02

The test results relate only to the samples tested.The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein. This report must not be used to claim product endorsement by CNLA, NVLAP, NIST or any agency of the Government. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.

DECLARATION OF CONFORMITY Per FCC Part 2 Section 2. 1077(a)

The following equipment:

Product Name : Secure Serial Device Server

Trade Name : Moxa

Model Number : NPort 6250, NPort 6250-M-SC, NPort 6250-S-SC

It’s herewith confirmed to comply with the requirements of FCC Part 15 Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that

may cause undesired operation.

The result of electromagnetic emission has been evaluated by QuieTek EMC laboratory (NVLAP Lab. Code : 200533-0 ) and showed in the test report. ( Report No. : 066L124-IT-US-P01V02 )

It is understood that each unit marketed is identical to the device as tested, and any changes to the device that could adversely affect the emission characteristics will require retest.

The following importer / manufacturer is responsible for this declaration:

Company Name

Company Address

Telephone Facsimile :

Person is responsible for marking this declaration:

Name ( Full name ) Position / Title

Date Legal Signature

Report No: 066L124-IT-US-P01V02

Page: 2 of 33

Test Report Cert i f icat ion Issued Date : <TestDate> Report No. : 066L124-IT-US-P01V02

Product Name : Secure Serial Device Server

Applicant : Moxa Technologies Co., Ltd

Address : Fl.4, No. 135, Lane 235, Pao-Chiao Rd., Shing Tien City,

Taipei, Taiwan, R.O.C.

Manufacturer : Moxa Technologies Co., Ltd

Model No. : NPort 6250,NPort 6250-M-SC,NPort 6250-S-SC

Rated Voltage : AC 120 V / 60 Hz

EUT Voltage : AC 100-240 V / 50-60 Hz

Trade Name : Moxa

Applicable Standard : FCC CFR Title 47 Part 15 Subpart B: 2005 Class B

CISPR 22: 2005

Test Result : Complied

Performed Location : Linkou EMC laboratory

No.5-22,Ruei-Shu Valley, Ruei-Ping Tsuen Lin Kuo

Shiang, Taipei, 244 Taiwan, R.O.C.

TEL:+866-2-8601-3788 / FAX:+886-2-8601-3789

Documented By :

( Genie Chang )

Reviewed By :

( Nick Chen )

Approved By :

( George Chen )

Report No: 066L124-IT-US-P01V02

Page: 3 of 33

Laboratory Information

We , QuieTek Corporation, are an independent EMC and safety consultancy that was established the whole facility in our laboratories. The test facility has been accredited by the following accreditation Bodies in compliance with ISO 17025, EN 45001 and Guide 25:

The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation’s Web Site : http://tw.quietek.com/modules/myalbum/ The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site : http://www.quietek.com/ If you have any comments, Please don’t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory :

No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : [email protected]

LinKou Testing Laboratory :

No. 5, Ruei-Shu Valley, Ruei-Ping Tsuen, Lin-Kou Shiang, Taipei, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected]

Taiwan R.O.C. : BSMI, DGT, CNLA

Germany : TUV Rheinland

Norway : Nemko, DNV

USA : FCC, NVLAP

Japan : VCCI

0914

1313

Report No: 066L124-IT-US-P01V02

Page: 4 of 33

TABLE OF CONTENTS Description Page 1. General Information .................................................................................................... 5 1.1. EUT Description................................................................................................... 5 1.2. Mode of Operation............................................................................................... 6 1.3. Tested System Details ......................................................................................... 7 1.4. Configuration of Tested System........................................................................... 8 1.5. EUT Exercise Software........................................................................................ 9 2. Technical Test ........................................................................................................... 10 2.1. Summary of Test Result..................................................................................... 10 2.2. List of Test Equipment ....................................................................................... 11 2.3. Measurement Uncertainty.................................................................................. 12 2.4. Test Environment ............................................................................................... 13 3. Conducted Emission (Main Terminals)...................................................................... 14 3.1. Test Specification............................................................................................... 14 3.2. Test Setup.......................................................................................................... 14 3.3. Limit ................................................................................................................... 14 3.4. Test Procedure .................................................................................................. 15 3.5. Deviation from Test Standard............................................................................. 15 3.6. Test Result ......................................................................................................... 16 3.7. Test Photograph ................................................................................................ 22 4. Radiated Emission.................................................................................................... 23 4.1. Test Specification............................................................................................... 23 4.2. Test Setup.......................................................................................................... 23 4.3. Limit ................................................................................................................... 23 4.4. Test Procedure .................................................................................................. 24 4.5. Deviation from Test Standard............................................................................. 24 4.6. Test Result ......................................................................................................... 25 4.7. Test Photograph ................................................................................................ 27 5. Attachment................................................................................................................ 28   EUT Photograph ................................................................................................ 28

Report No: 066L124-IT-US-P01V02

Page: 5 of 33

1. General Information

1.1. EUT Description

Product Name Secure Serial Device Server Trade Name Moxa Model No. NPort 6250,NPort 6250-M-SC,NPort 6250-S-SC

Component

Power Adapter MFR: BALANCE, M/N: GPSA-1200125 Input: AC100-240 V , 50-60 Hz Output: DC 12 V, 1.2A Cable Out: Non-Shielded, 1.8m Power Cord: Non-Shielded, 1.8m

Report No: 066L124-IT-US-P01V02

Page: 6 of 33

1.2. Mode of Operation QuieTek has verified the construction and function in typical operation. All the test modes were carried out with the EUT in normal operation, which was shown in this test report and defined as: Pre-Test Mode

Mode 1:Secure Device Server NPort 6250 Mode 2:Secure Device Server NPort 6250-S-SC Mode 3:Secure Device Server NPort 6250-MSC

Final Test Mode

Emission Mode 1:Secure Device Server NPort 6250

Report No: 066L124-IT-US-P01V02

Page: 7 of 33

1.3. Tested System Details The types for all equipments, plus descriptions of all cables used in the tested system (including inserted cards) are:

Product Manufacturer Model No. Serial No. Power Cord

1 Notebook PC DELL PPT N/A Non-Shielded, 0.8m

Report No: 066L124-IT-US-P01V02

Page: 8 of 33

1.4. Configuration of Tested System

Connection Diagram

Signal Cable Type Signal cable Description

A LAN Cable Non-Shielded, 7m

Report No: 066L124-IT-US-P01V02

Page: 9 of 33

1.5. EUT Exercise Software

1 Setup the EUT and simulators as shown on 1.4. 2 Turn on the power of all equipment. 3 Run IBM test program (Rtpx Rev:3.3), reads data from disk. 4 Personal Computer sends“H”pattern to printer, the printer will print“H”pattern on paper. 5 Personal Computer reads and writes data into and from modem. 6 Personal Computer will read data from floppy disk and then writes the data into floppy disk , same

operation for hard disk. 7 Repeat the above procedure (4) to (6).

Report No: 066L124-IT-US-P01V02

Page: 10 of 33

2. Technical Test

2.1. Summary of Test Result

No deviations from the test standards Deviations from the test standards as below description:

Emission

Performed Item Normative References Test

Performed Deviation

Conducted Emission FCC CFR Title 47 Part 15 Subpart B: 2005

Class BANSI C63.4: 2003

Yes No

Radiated Emission FCC CFR Title 47 Part 15 Subpart B: 2005

Class B ANSI C63.4: 2003

Yes No

Report No: 066L124-IT-US-P01V02

Page: 11 of 33

2.2. List of Test Equipment Conducted Emission / SR1 Instrument Manufacturer Type No. Serial No Cal. Date EMI Test Receiver R&S ESCS 30 836858/022 2006/02/18 LISN R&S ENV4200 833209/007 2005/07/27 LISN R&S ESH3-Z5 836679/020 2006/02/14 Pulse Limiter R&S ESH3-Z2 357.88.10.52 2005/09/07 Radiated Emission / Site3 Instrument Manufacturer Type No. Serial No Cal. Date Bilog Antenna Schaffner Chase CBL6112B 2704 2005/09/15 Broadband Horn Antenna Schwarzbeck BBHA9170 208 2005/07/25 EMI Test Receiver R&S ESCS 30 838251/001 2006/05/11 EMI Test Receiver R&S ESI 26 838786/004 2006/05/25 Horn Antenna Schwarzbeck BBHA9120D 305 2005/08/10 Pre-Amplifier QTK N/A N/A 2006/01/03

Pre-Amplifier MITEQ AMF-4D-180400-45-6P 925974 2006/01/03

Spectrum Analyzer Advantest R3162 101102468 2005/10/24

Report No: 066L124-IT-US-P01V02

Page: 12 of 33

2.3. Measurement Uncertainty Conducted Emission

The measurement uncertainty is evaluated as ± 2.26 dB.

Radiated Emission The measurement uncertainty is evaluated as ± 3.19 dB.

Report No: 066L124-IT-US-P01V02

Page: 13 of 33

2.4. Test Environment

Performed Item Items Required Actual

Temperature (°C) 15-35 25

Conducted Emission

Humidity (%RH) 25-75 50

Barometric pressure (mbar) 860-1060 950-1000

Temperature (°C) 15-35 25

Radiated Emission

Humidity (%RH) 25-75 50

Barometric pressure (mbar) 860-1060 950-1000

Report No: 066L124-IT-US-P01V02

Page: 14 of 33

3. Conducted Emission (Main Terminals)

3.1. Test Specification According to EMC Standard : EN 55022

3.2. Test Setup

3.3. Limit

Limits

Frequency (MHz)

QP (dBuV)

AV (dBuV)

0.15 - 0.50 66 - 56 56 – 46

0.50-5.0 56 46

5.0 - 30 60 50

Remarks: In the above table, the tighter limit applies at the band edges.

Report No: 066L124-IT-US-P01V02

Page: 15 of 33

3.4. Test Procedure The EUT and simulators are connected to the main power through a line impedance stabilization network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the measuring equipment. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test setup and photographs.) Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed on conducted measurement.

Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz using a receiver bandwidth of 9kHz.

3.5. Deviation from Test Standard No deviation.

Report No: 066L124-IT-US-P01V02

Page: 16 of 33

3.6. Test Result Site : SR-1 Time : 2006/06/17 - 11:35

Limit : CISPR_B_00M_QP Margin : 10

EUT : SECERE SERIAL DEVICE SERVER Probe : LISN-020(L) - Line1

Power : AC 120V/60Hz Note : MODE 1

Report No: 066L124-IT-US-P01V02

Page: 17 of 33

Site : SR-1 Time : 2006/06/17 - 11:37

Limit : CISPR_B_00M_QP Margin : 0

EUT : SECERE SERIAL DEVICE SERVER Probe : LISN-020(L) - Line1

Power : AC 120V/60Hz Note : MODE 1

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.205 0.202 41.290 41.492 -22.937 64.429 QUASIPEAK

2 * 0.548 0.217 41.390 41.607 -14.393 56.000 QUASIPEAK

3 0.685 0.229 36.790 37.019 -18.981 56.000 QUASIPEAK

4 1.580 0.261 34.650 34.911 -21.089 56.000 QUASIPEAK

5 6.041 0.450 39.090 39.540 -20.460 60.000 QUASIPEAK

6 23.130 1.068 40.670 41.738 -18.262 60.000 QUASIPEAK

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Report No: 066L124-IT-US-P01V02

Page: 18 of 33

Site : SR-1 Time : 2006/06/17 - 11:37

Limit : CISPR_B_00M_AV Margin : 0

EUT : SECERE SERIAL DEVICE SERVER Probe : LISN-020(L) - Line1

Power : AC 120V/60Hz Note : MODE 1

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.205 0.202 39.720 39.922 -14.507 54.429 AVERAGE

2 * 0.548 0.217 39.600 39.817 -6.183 46.000 AVERAGE

3 0.685 0.229 33.870 34.099 -11.901 46.000 AVERAGE

4 1.580 0.261 31.580 31.841 -14.159 46.000 AVERAGE

5 6.041 0.450 37.750 38.200 -11.800 50.000 AVERAGE

6 23.130 1.068 36.480 37.548 -12.452 50.000 AVERAGE

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Report No: 066L124-IT-US-P01V02

Page: 19 of 33

Site : SR-1 Time : 2006/06/17 - 11:39

Limit : CISPR_B_00M_QP Margin : 10

EUT : SECERE SERIAL DEVICE SERVER Probe : LISN-020(N) - Line2

Power : AC 120V/60Hz Note : MODE 1

Report No: 066L124-IT-US-P01V02

Page: 20 of 33

Site : SR-1 Time : 2006/06/17 - 11:41

Limit : CISPR_B_00M_QP Margin : 0

EUT : SECERE SERIAL DEVICE SERVER Probe : LISN-020(N) - Line2

Power : AC 120V/60Hz Note : MODE 1

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.205 0.202 34.550 34.752 -29.677 64.429 QUASIPEAK

2 0.685 0.225 37.390 37.615 -18.385 56.000 QUASIPEAK

3 1.576 0.261 36.630 36.891 -19.109 56.000 QUASIPEAK

4 3.431 0.335 36.970 37.305 -18.695 56.000 QUASIPEAK

5 * 6.037 0.410 41.290 41.700 -18.300 60.000 QUASIPEAK

6 23.127 0.808 39.030 39.838 -20.162 60.000 QUASIPEAK

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Report No: 066L124-IT-US-P01V02

Page: 21 of 33

Site : SR-1 Time : 2006/06/17 - 11:41

Limit : CISPR_B_00M_AV Margin : 0

EUT : SECERE SERIAL DEVICE SERVER Probe : LISN-020(N) - Line2

Power : AC 120V/60Hz Note : MODE 1

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.205 0.202 32.500 32.702 -21.727 54.429 AVERAGE

2 0.685 0.225 35.400 35.625 -10.375 46.000 AVERAGE

3 1.576 0.261 34.480 34.741 -11.259 46.000 AVERAGE

4 3.431 0.335 34.370 34.705 -11.295 46.000 AVERAGE

5 * 6.037 0.410 40.230 40.640 -9.360 50.000 AVERAGE

6 23.127 0.808 35.680 36.488 -13.512 50.000 AVERAGE

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Report No: 066L124-IT-US-P01V02

Page: 22 of 33

3.7. Test Photograph Test Mode : Mode 1:Secure Device Server NPort 6250 Description : Front View of Conducted Test

Test Mode : Mode 1:Secure Device Server NPort 6250 Description : Back View of Conducted Test

Report No: 066L124-IT-US-P01V02

Page: 23 of 33

4. Radiated Emission

4.1. Test Specification According to EMC Standard : EN 55022

4.2. Test Setup

4.3. Limit

Limits Frequency

(MHz) Distance (m) dBuV/m

30 – 230 10 30

230 – 1000 10 37

Remark: 1. The tighter limit shall apply at the edge between two frequency bands. 2. Distance refers to the distance in meters between the measuring instrument antenna and

the closed point of any part of the device or system.

Report No: 066L124-IT-US-P01V02

Page: 24 of 33

4.4. Test Procedure The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT was positioned such that the distance from antenna to the EUT was 10 meters. The antenna can move up and down between 1 meter and 4 meters to find out the maximum emission level. Both horizontal and vertical polarization of the antenna are set on measurement. In order to find the maximum emission, all of the interface cables must be manipulated on radiated measurement. Radiated emissions were invested over the frequency range from 30MHz to1GHz using a receiver bandwidth of 120kHz. Radiated was performed at an antenna to EUT distance of 10 meters.

4.5. Deviation from Test Standard No deviation.

Report No: 066L124-IT-US-P01V02

Page: 25 of 33

4.6. Test Result Site : OATS-3 Time : 2006/06/20 - 03:21

Limit : CISPR_B_10M_QP Margin : 6

EUT : Secure Serial Device Server Probe : LKCBL6112(2704) - HORIZONTAL

Power : AC 120V/60Hz Note : MODE 1

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV/m)

Margin

(dB)

Limit

(dBuV/m)

Detector Type

1 43.600 12.578 13.750 26.328 -3.672 30.000 QUASIPEAK

2 125.000 13.649 5.200 18.849 -11.151 30.000 QUASIPEAK

3 * 250.000 14.376 19.820 34.196 -2.804 37.000 QUASIPEAK

4 500.000 19.802 5.600 25.402 -11.598 37.000 QUASIPEAK

5 750.000 22.924 4.700 27.624 -9.376 37.000 QUASIPEAK

6 864.013 24.328 4.370 28.698 -8.302 37.000 QUASIPEAK

Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Report No: 066L124-IT-US-P01V02

Page: 26 of 33

Site : OATS-3 Time : 2006/06/20 - 03:29

Limit : CISPR_B_10M_QP Margin : 6

EUT : Secure Serial Device Server Probe : LKCBL6112(2704) - VERTICAL

Power : AC 120V/60Hz Note : MODE 1

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV/m)

Margin

(dB)

Limit

(dBuV/m)

Detector Type

1 42.800 11.774 14.900 26.674 -3.326 30.000 QUASIPEAK

2 58.730 6.699 19.120 25.819 -4.181 30.000 QUASIPEAK

3 * 108.780 12.468 15.460 27.928 -2.072 30.000 QUASIPEAK

4 125.000 12.194 11.960 24.154 -5.846 30.000 QUASIPEAK

5 148.460 11.440 15.750 27.190 -2.810 30.000 QUASIPEAK

6 210.000 11.203 9.620 20.823 -9.177 30.000 QUASIPEAK

7 250.000 14.415 18.970 33.385 -3.615 37.000 QUASIPEAK

8 410.446 20.695 2.840 23.535 -13.465 37.000 QUASIPEAK

9 864.010 24.084 5.390 29.474 -7.526 37.000 QUASIPEAK

Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Report No: 066L124-IT-US-P01V02

Page: 27 of 33

4.7. Test Photograph Test Mode : Mode 1:Secure Device Server NPort 6250 Description : Front View of Radiated Test

Test Mode : Mode 1:Secure Device Server NPort 6250 Description : Back View of Radiated Test

Report No: 066L124-IT-US-P01V02

Page: 28 of 33

5. Attachment EUT Photograph

(1) EUT Photo

(2) EUT Photo

Report No: 066L124-IT-US-P01V02

Page: 29 of 33

(3) EUT Photo

(4) EUT Photo

Report No: 066L124-IT-US-P01V02

Page: 30 of 33

(5) EUT Photo

(6) EUT Photo

Report No: 066L124-IT-US-P01V02

Page: 31 of 33

(7) EUT Photo

(8) EUT Photo

Report No: 066L124-IT-US-P01V02

Page: 32 of 33

(9) EUT Photo

(10) EUT Photo

Report No: 066L124-IT-US-P01V02

Page: 33 of 33

(11) EUT Photo

(12) EUT Photo