06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

36
06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th , 2006
  • date post

    19-Dec-2015
  • Category

    Documents

  • view

    215
  • download

    0

Transcript of 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Page 1: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

06213 – Hydrogen Fuel Cell Test Station

Preliminary Design Review

February 24th, 2006

Page 2: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Group Members• Team Leader: Chad Byler (ME)

• Mechanical Press & Fuel Flow:Dan Upton (ME), Brian Holzberger (ME), &

Sean Ashman (ME)

• Electrical Sensors & Power Supply:Dennis Farley (EE) & Steve Yang (EE)

• Data Acquisition & Software: Shan Hu (CE)

• Process and Safety: Corey Reynolds (ISE)

Project Mentor: Dr. Bailey(ME)

Page 3: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Project Sponsor

• Nanopower Research Laboratory

– Funding• Dr. Rafaelle – Department of Physics at RIT

– Customer Contact• Cory Cress – PhD student in Microsystems

http://www.rit.edu/~physics/Research/nanopower.shtml

Page 4: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Subsystem Topics

• Layering of Fuel Cell• Mechanical Assembly Process• Heating of the Fuel Cell• Humidification of gas• Exhaust/Back Pressure Control• Electrical Sensors and Power Supply• Heating elements• Layout of program logic• Data Acquisition• Budget

But First…

Page 5: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Cathode Reactions:

1/2 O2 + 2e- O-2ion

Porous gas diffusion layer Porous gas diffusion layer2e- 2e-

Reaction Products(H2O only)

Air/O2H2

O2

Catalyst LayersActive Material:Platinum or Platinum/Ruthenium

Thin solid hydrated Membrane as an Electrolyte

Anode Reactions:

H2 2H+ + 2e-

H+ion

proton

2H+ + O-2ion H2O

PEM = Low temperature (80oC) hydrogen fuel cell with polymer electrolyte and precious metal electrodes

Fuel Cell Operation

Cathode = gas diffusion layer + catalyst layer

Anode = gas diffusion layer + catalyst layer

Page 6: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Location - Fuel Cell Assembly

Page 7: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Electrode Plate

–Raised center portion to ensure maximum pressure of electrode with nano-tube catalyst.–Three different sizes for reaction area.

Page 8: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Fuel Cell Assembly

Nano-tube catalyst

PEM

Page 9: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Fuel Cell Stack

Page 10: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Location - Fuel Cell Assembly

Page 11: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Mechanical Assembly

• Ease of Operation•Backing Plate rotates to allow assembly on horizontal surface.•Pegs hold fuel cell assembly in place until it can be compressed.

• Repeatability•Use of power screw in combination with a pressure sensor or a torque wrench will allow for a repeatable mechanical pressure applied to the fuel cell.•The use of the mechanical assembly gives the ability to encapsulate the fuel cell and regulate the temperature.

Page 12: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Mechanical Assembly Animation

Page 13: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Power Screw CalculationsInternal Pressure 120 psi  

Surface Area 2.64 in^2  

Max Force 316.8 lb  

   

tan() must be less than the coefficient of friction in order to be postitive locking

Screw Type: 1/2" - 10  

Lead L= 0.1 in  

Root Dia. Dr= 0.45 in  

   

tan()=L/(*Dr)        

tan()= 0.071      

= 0.3 Coefficient of friction steel to steel  

tan() < , therefore the screw is self locking  

   

T=F*Dr/2*((L+**Dr)/(*Dr-*L)  

   

T = 26.999 Lb/in  

T = 2.25 Lb/ft            

Page 14: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Location - Fuel Cell Heating

Page 15: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Fuel Cell Heating

Page 16: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Steady-State Temperature Distribution without Insulation (O2 side)

-Shows need for cell Insulation

-With insulation all cell components reach 80°C at S.S.

Page 17: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Location - Humidification

Page 18: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Gas Humidification Method

•H2 or O2 inlet in base

•Bubble up through water

•Temperature of water controls the humidity of exit gas

•Resistive heater used to heat water

•Water temperature monitored to ensure safe heating

Page 19: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Expansion Valve

Contains:• Pressure Sensor• Humidity Sensor• Temperature Sensor

Pros:• Interchangeable• Non-Intrusive to flow

Page 20: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Location – Back Pressure

Page 21: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Exhaust/Pressure Regulation

• Constant Upstream Pressure

• Bleeds overpressure• Ability to dry PEM• Bubbles prove flow• Water seal provides

no upstream airflow

Page 22: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Overview Schematic

Page 23: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Important Sensor Parameters

• National Semiconductor LM34 Temperature Sensor:– Maximum Current Draw: 90μA– Maximum Output Current: 160μA– Maximum Output Voltage: 6V– Accuracy: 0.555°C– Operating range: -45°C to 150°C

• Honeywell HIH-3610 Humidity Sensor:– Maximum Current Draw: 200μA– Maximum Output Current: 100μA– Maximum Output Voltage: 3.9V– Accuracy: 2% Relative Humidity– Operating Range: 0 to 100% Relative Humidity in -40°C to 85°C

Page 24: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Important Sensor Parameters Cont.

• Honeywell ASDX100G24R Gas Pressure Sensor :– Maximum Current Draw: 10mA– Maximum Output Current: 2mA– Maximum Output Voltage: 5V– Accuracy: 2% of Operating range– Operating range: 0 to 100 PSI in 0°C to 85°C

• Honeywell TD4A Liquid Temperature Sensor:– Maximum Current Draw: 26.3mA– Maximum Output Current: 1mA– Maximum Output Voltage: 2.5V– Accuracy: 1°C– Operating Range: -40°C to 150°C

Page 25: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Worst Case Analysis

Maximum Current Draw:• For Heaters: 0.83A maximum per heater * 3 = 2.5A

maximum• For LM34 Temperature Sensors: 90μA * 3 = 270μA• For HIH-3610 Humidity Sensors: 200μA * 2 = 400μA• For ASDX100G24R Gas Pressure Sensor: 10mA * 2 =

20mA• For Underwater Temp Sensor: 26.3mA * 3 = 78.9mA

• Total Current Draw = 2.51056A

Page 26: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Heater Analysis

• 58200 Joules are needed to heat the water in our largest tank, 0.2317L, from 20°C to 80°C– Using an Omega CIR-3016 (100 Watt)

– Therefore, the longest time needed to heat the water is 9.7 minutes

min7.9sec60

min1sec*582

sec582100

sec)*58200(

W

W

Page 27: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Omega Immersion Cartridge Heater

• 150 Watt Heater

• Incoloy® Sheath - Efficient heat transfer - Sealed tip

- Corrosion resistant.

• Special Insulation - High dielectric strength - Faster heat-up time

• Small size - 1/2 inch diameter

Water Heating Source

Page 28: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Water Temperature Sensor

TD4A - Liquid Temperature Sensor

• RTD (resistance temperature detector) sensors

• Respond rapidly to temperature changes

• Accurate to ± 0.7 °C at 20 °C

• Temp. range: -40 °C to 150 °C (-40 °F to 302 °F)

• Supply Voltage/Current: 10Vdc, 1mA typ.

• Linear outputs.

Page 29: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Power Controllers

Power-IO Solid State Relays

• Surge protection

• DC control input: 4-32VDC

• Operating Voltage: 24-330V

• Max Load Current: 25A

• Affordable price (under $40)

Page 30: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Software Design Flowchart I Start

User input desired testing parameters (Temp/Humidity/Pressure/Duration)and the max pressure, max temperature should be allowed

Test Temperature sensor

Is temp sensor ok?Show error message!

Terminate the program!

End

Set up testing environments

Start testing?

All desired testing parameters are

satisfied?Show violation message!

Timer counts

End test?

Record testing results

Continue without adjustment?

N

Y

Y

Y

Y

Y

N

N

N

N

Page 31: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Software Design Flowchart IISet up testing environments

Heat H2 and O2

water tank

Exceed max water temp?

Show warning!

Desired gas humidity?

Y

N

End set up testing environments

DisplayGas

Temp(H2 and

O2)

Display water temperature

Display gas humidity (H2 and O2)

Desired temp?

Display PEMtemperature

N

Y

Y

N

Y

Desired gaspressure?

Adjust pressure of H2 and O2 gas

Display pressureof H2 and O2 gas line

Heat PEMwater tank

Exceed max water temp?

N

YN

Dangerouslevel?

ShutOff!

YN

Show warning!

Dangerouslevel?

ShutOff!

Y N

Exceed max gas pressure? Y

N Show warning!

Dangerouslevel?

ShutOff!

Y N

Page 32: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

USB-1208LS + LabVIEW™ drivers     USB-based DAQ module ( $109.00 x 2 + $ 49.00)

•8 Single-Ended or 4 Differential Analog Inputs •12-bit (Diff.)/11-bit (SE) Resolution •Two 10-bit Analog Outputs •One 32-bit External Event Counter •16 Digital I/O Lines •External Trigger Input•Sample Rate 1.2KS/s

Page 33: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Design ProcessOriginal Project Objectives

1. Flow Systems

2. H2 & O2 Electrolysis and Delivery

3. Temperature Systems

4. Pressure Systems

5. Humidity Systems

6. Mechanical Assembly (Optional)

Current Project Objectives

1. Mechanical Assembly

2. H2 & O2 Creation and Delivery

3. Temperature Systems

4. Pressure Systems

5. Humidity Systems

Flow System

Electrolysis System

H2 & O2 Tanks

Flow System

Major Project Scope Changes

Scope Change Impact

Research

Concept Generation

Concept Selection

Feasibility Analysis

Time

Page 34: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Project Schedule

Page 35: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Budget

Page 36: 06213 – Hydrogen Fuel Cell Test Station Preliminary Design Review February 24 th, 2006.

Questions