03456 00 14 85 hss.com/abird-apex · Fuel management – check your fuel levels quickly and never...

24
03456 00 14 85 hss.com/abird-apex

Transcript of 03456 00 14 85 hss.com/abird-apex · Fuel management – check your fuel levels quickly and never...

03456 00 14 85hss.com/abird-apex

COMPLETE POWERMANAGEMENT

REMOTE FLEET MANAGEMENT

FUEL SUPPLY

ECO FRIENDLY

FUEL EFFICIENCY SILENCED RUNNING

REDUCED CO2EMISSIONS

MONITOR PERFORMANCE INCREASE SECURITY REDUCE RUNNING COSTS

Our generator range delivers:

SEE PAGES 10-11 OR CALL 03456 00 14 85

TAKE THE HASSLE AWAY

Smart EquipmentSmart EquipmentenabledRFM

MANAGEMENTMANAGEMENTFIND OUT MORE ON

PAGES 6-7

SEE PAGE 23 TO FIND YOUR NEAREST DEPOT

SITE SURVEYS CONTINGENCY PLANS SPECIFICATION DELIVERY AND INSTALLATION FUEL SUPPLY MAINTENANCE

E

F

INDUSTRY EXPERTISEPage 4-5

RFM ENABLED SMART EQUIPMENTPage 6

LITHIUM HARVEST AND HYBRID SOLUTIONSPage 7-9

FUEL MANAGEMENTPage 10-11

GENERATOR GUIDEPages 12-13

SILENCED GENERATORS Pages 14-17

DISTRIBUTION BOARDS & ACCESSORIES Pages 18

LOADBANKS & LIGHTING Pages 19

HSS HIRE GROUPPage 20-21

HERE FOR YOUPage 22

DEPOT FINDERPage 23

CONTENTSINDUSTRY EXPERTISEINDUSTRY EXPERTISEINDUSTRY EXPERTISEINDUSTRY

Expert advice, account

management and service response.

We're here for you!

HERE FOR

YOU

SEE PAGE 22 FOR MORE INFORMATION.

3hss.com/abird-apex 03456 00 14 85

DATA CENTRES & CRITICAL SUPPLYDelivering optimum performance and continuous operation is crucial across web services, healthcare and fi nancial institutions.

EVENTSBespoke solutions for temporary events where total power

requirements vary for each event, whether large or small.

CONSTRUCTIONExperience with project critical requirements, varied site

complexity and operational site effi ciency.

INDUSTRY EXPERTISE

4 03456 00 14 85 hss.com/abird-apex

INFRASTRUCTUREKeeping the country operational through transportation and communication lines.

MININGOffering temporary power to open-cut and

underground mining operations.

RENEWABLESWorking across a range of applications including wind, solar and tidal we construct, commission and maintain their power requirements.

INDUSTRIAL/MANUFACTURINGEnsuring constant power to avoid production downtime

and maintain profi tability.

5hss.com/abird-apex 03456 00 14 85

RFM is Remote Fleet Management, a seriously smart technology that gives you complete visibility of your equipment on hire. Rather than leaving your generator on site or at your premises and having to run and check how it’s performing, RFM lets you do it all through your desktop, tablet or mobile using our specialist website and connected app.

WHAT CAN I FIND OUT?Map overview – you can see where each machine you have on hire from us is located, as well as being able to fi lter the results if you want to look at a specifi c site or location. Selecting a unit will show you serial number, model and closest depot to that generator.

Machine performance – as well as seeing what you have on hire, you can also see how effectively it’s working. View fuel levels, operating hours, oil pressure, battery levels and engine temperature.

WHAT ARE THE BENEFITS OF RFM? Increased security – know where all your equipment is at all times, and if it’s moved off site we can track it.

Reduced running costs – better visibility of energy usage can help you manage your power usage more effi ciently.

Fuel management – check your fuel levels quickly and never run out of fuel again, even order fuel at the touch of a button. Alternatively, you can hand the whole process over to us and we’ll make sure you never have to worry about your fuel levels by automatically topping them up for you.

Easier access to support services – if you need to book a service, off-hire equipment or request a call back from one of the team, you can do so at the touch of a button.

Equipment usage overview - ability to check that the right size equipment is onsite based on the power usage and that there is no fuel wastage.

RFM ENABLED SMART EQUIPMENT

Smart EquipmentSmart EquipmentenabledRFM

6 03456 00 14 85 hss.com/abird-apex

LITHIUM HARVEST Ideally paired with diesel generators from 45kVA to 150kVA, the Lithium Harvest Energy System is a compact add on unit which harvests any excess energy created by your generator and not used by your equipment. It then stores this energy for you to use whenever you might need it, so you get the most out of your generator and fuel.

COMPACT & QUICK TO CHARGEThe Harvest System sits alongside your generators to harvest the excess power while they’re operating. The Lithium Ion battery allows the system to charge and be ready to use in just two hours.

Technical Specifications

Code 25266

Dimensions (LxWxH) 1180mmx780mmx1270mm

Max Load Before Gen Start Command 21kVA 400V

Max Autonomous Power - 10hrs 4kVA

Energy Storage 41

Output Connection 63A, Three Phase, 230V

REDUCE YOUR FUEL COSTSBy harvesting the over-production from your generators, you can make sure no power is going to waste. You’ll be getting the most from your generator and the fuel it’s using.

CLEANER, QUIETER ENERGYThe energy from the Harvest System is cleaner and quieter than that generated by a traditional diesel generator, which makes it ideal for night working, or in noise sensitive areas. You’ll also be reducing your CO2 emissions.

7hss.com/abird-apex 03456 00 14 85

• 24/7 noise from diesel genset.

• Site uses more fuel and therefore creates more CO2, NOx and PMs

• No backup power in the event of diesel genset breakdown.

• There is an increased frequency of diesel genset servicing and breakdowns due to inefficient running at low loads.

DID YOU KNOW?

THIS MEANS...

• Many diesel generators are inefficient at low loads. They consume more fuel per kWh, compared to when operating between 60-80% of capacity.

• Site generators are often over-specified, meaning they frequently run at less than 25% capacity.

• Typically, the same generator providing the higher daytime power, is continually running 24/7 to provide a lower overnight load, consuming large of amounts of diesel fuel overnight, unnecessarily.

Average consumption rates shown for illustrative purposes, based on collated manufacturer data.1Based on 100 hours per week HPG run time. 2Based on 75p per litre. 3Based on 52 Weeks.

Lithium Hybrid System

Diesel Generator Size (kVA)

1Fuel Saving

Litres per week

2Fuel Saving

per week

CO2 per week

(Tonnes)

3AnnualSavings

Annual CO2

Savings (Tonnes)

24 kVA / 41 kWh

60 700 £525 1.9 £27,300 97

24 kVA / 41 kWh

100 950 £713 2.5 £37,050 132

24 kVA / 41 kWh

150 1300 £975 3.5 £50,700 180

POTENTIAL HYBRID SAVINGS

8 03456 00 14 85 hss.com/abird-apex

TYPICAL HYBRID SITE SET UP

SCENARIO 1: TIMER SETTINGSThe hybrid controls the automatic operation of the diesel set. The diesel set runs through the day, and then the hybrid turns the diesel set off, running the site silently on the hybrid. eg. 6am - 6pm diesel. 6pm - 6am: Hybrid.

SCENARIO 2: LOAD SENSINGThe hybrid automatically switches off the diesel generator when it is running at low loads. The hybrid re-charges when the diesel generator is running for higher loads ensuring fuel consumption is optimised.

SCENARIO 3: CONSTANT LOW LOADThe hybrid is the primary power source, and only switches on the diesel generator to re-charge the batteries. The diesel generator runs at a much higher load improving fuel efficiency.

Auto Start Cable 60 - 200 kVA

CYGNUS HPG THREE24 kVA / 48 kWh

24 hr circuits - Drying Room - Security Cabin - Welfare Cabin

Daytime circuits - General Office - Storage - Workshops - Site power

Typical hybrid site set up

Commonly used termsLoad sensing modeThe hybrid will turn diesel generator on/off depending on load and battery state of charge

Timer modeThe hybrid will turn diesel generator on/off according to pre-programmed day/time settings

SCENARIO 1: TIMER SETTINGSThe hybrid controls the automatic operation of the diesel set. The diesel set runs through the day, and then the hybrid turns the diesel set off, running the site silently on the hybrid. eg. 6am - 6pm diesel. 6pm - 6am

SCENARIO 2: LOAD SENSINGThe hybrid automatically switches off the diesel generator when it is running at low loads. The hybrid re-charges when the diesel generator is running for higher loads and thus fuel consumption is optimised.

SCENARIO 3: CONSTANT LOW LOADThe hybrid is the primary power source, and only switches on the diesel generator to re-charge the batteries. The diesel generator runs at a much higher load improving fuel efficiency.

DIESEL POWER BY DAY

SILENT HYBRID POWER BY NIGHT

Full site backupAll power to site is passed through hybrid from generator

Sub-systemPart of site (eg. Drying Room, Critical Power) is supported by hybrid - see illustration above

Auto Start Cable

24 hr circuits - Drying Room - Security Cabin - Welfare Cabin

20 - 80 kVA

CYGNUS HPG THREE 24 kVA 50kWh

SUB-SYSTEM (PART SITE)

FULL SITE

ANY QUESTIONS CONTACT FIREFLY 01273 40 95 95 [email protected]

© Firefly Solar Generators Ltd

SUB-SYSTEM (PART SITE) Auto Start Cable 60 - 200 kVA

CYGNUS HPG THREE24 kVA / 48 kWh

24 hr circuits - Drying Room - Security Cabin - Welfare Cabin

Daytime circuits - General Office - Storage - Workshops - Site power

Typical hybrid site set up

Commonly used termsLoad sensing modeThe hybrid will turn diesel generator on/off depending on load and battery state of charge

Timer modeThe hybrid will turn diesel generator on/off according to pre-programmed day/time settings

SCENARIO 1: TIMER SETTINGSThe hybrid controls the automatic operation of the diesel set. The diesel set runs through the day, and then the hybrid turns the diesel set off, running the site silently on the hybrid. eg. 6am - 6pm diesel. 6pm - 6am

SCENARIO 2: LOAD SENSINGThe hybrid automatically switches off the diesel generator when it is running at low loads. The hybrid re-charges when the diesel generator is running for higher loads and thus fuel consumption is optimised.

SCENARIO 3: CONSTANT LOW LOADThe hybrid is the primary power source, and only switches on the diesel generator to re-charge the batteries. The diesel generator runs at a much higher load improving fuel efficiency.

DIESEL POWER BY DAY

SILENT HYBRID POWER BY NIGHT

Full site backupAll power to site is passed through hybrid from generator

Sub-systemPart of site (eg. Drying Room, Critical Power) is supported by hybrid - see illustration above

Auto Start Cable

24 hr circuits - Drying Room - Security Cabin - Welfare Cabin

20 - 80 kVA

CYGNUS HPG THREE 24 kVA 50kWh

SUB-SYSTEM (PART SITE)

FULL SITE

ANY QUESTIONS CONTACT FIREFLY 01273 40 95 95 [email protected]

© Firefly Solar Generators Ltd

Auto Start Cable 60 - 200 kVA

CYGNUS HPG THREE24 kVA / 48 kWh

24 hr circuits - Drying Room - Security Cabin - Welfare Cabin

Daytime circuits - General Office - Storage - Workshops - Site power

Typical hybrid site set up

Commonly used termsLoad sensing modeThe hybrid will turn diesel generator on/off depending on load and battery state of charge

Timer modeThe hybrid will turn diesel generator on/off according to pre-programmed day/time settings

SCENARIO 1: TIMER SETTINGSThe hybrid controls the automatic operation of the diesel set. The diesel set runs through the day, and then the hybrid turns the diesel set off, running the site silently on the hybrid. eg. 6am - 6pm diesel. 6pm - 6am

SCENARIO 2: LOAD SENSINGThe hybrid automatically switches off the diesel generator when it is running at low loads. The hybrid re-charges when the diesel generator is running for higher loads and thus fuel consumption is optimised.

SCENARIO 3: CONSTANT LOW LOADThe hybrid is the primary power source, and only switches on the diesel generator to re-charge the batteries. The diesel generator runs at a much higher load improving fuel efficiency.

DIESEL POWER BY DAY

SILENT HYBRID POWER BY NIGHT

Full site backupAll power to site is passed through hybrid from generator

Sub-systemPart of site (eg. Drying Room, Critical Power) is supported by hybrid - see illustration above

Auto Start Cable

24 hr circuits - Drying Room - Security Cabin - Welfare Cabin

20 - 80 kVA

CYGNUS HPG THREE 24 kVA 50kWh

SUB-SYSTEM (PART SITE)

FULL SITE

ANY QUESTIONS CONTACT FIREFLY 01273 40 95 95 [email protected]

© Firefly Solar Generators Ltd

FULL SITE

9hss.com/abird-apex 03456 00 14 85

NEVER RUN OUT OF FUEL AGAIN

At ABird and Apex we’re more than just generator suppliers. We also offer a reliable fuel management supply service which takes the hassle away associated with planning fuel deliveries, ensures continuous supply, reduces downtime and costly re-start costs.

FUEL MANAGEMENT

> REDUCE COSTS > REDUCE RISKS > REDUCE DOWNTIME > REDUCE LAND CONTAMINATION

10 03456 00 14 85 hss.com/abird-apex

We can regularly assess the power and fuel usage of your site and advise how you can make savings, either by using lower kVA generators or by using our Lithium Harvest Energy System to make sure you're using all your power effi ciently.

Remote Fleet Management technology gives us total visibility of your fl eet 24 hours a day, 7 days a week. So if your tanks are running low we can resupply fuel or if someone is draining your tanks illegally, we'll even spot that.

FUEL STATION One of the biggest risks is moving fuel around site, but with our fuel station it allows you to keep all refuelling in one location. Following a site survey we will recommend the best location for the fuel station to reduce risk of land contamination.

A dedicated fuel desk monitors the onsite fuel station's levels and triggers a replenishment supply at 30% and 15%. So there is no chance it will ever run out of fuel again.

FUEL MANAGEMENT

11hss.com/abird-apex 03456 00 14 85

ASK U

S ABO

UT O

UR FU

EL M

ANAG

EMEN

T SER

VICE

SGENERATOR GUIDE

Code Max Power

Fuel Type

Fuel Tank

Capacity (L)

Hardwire Facility

Road Towable Silenced

Runtime (hrs) @ 3/4 load

X6035/A6035 20kVA Diesel 75 Y - Y 20

X6040/A6040 30kVA Diesel 135 Y - Y 29

X6044/A6044 40kVA Diesel 135 Y - Y 20

X6050/A6050 60kVA Diesel 185 Y - Y 18

X6022/A6022 100kVA Diesel 180 Y - Y 12

X6027/A6027 150kVA Diesel 400 Y - Y 17

X6031/A6031 180kVA Diesel 400 Y - Y 14

X6034/A6034 200kVA Diesel 400 Y - Y 14

X6037/A6037 250kVA Diesel 450 Y - Y 10

X6039/A6039 300kVA Diesel 450 Y - Y 9

12 03456 00 14 85 hss.com/abird-apex

ASK US ABOUT OUR FUEL MANAGEMENT SERVICESGENERATOR GUIDE

Code Max Power

Fuel Type

Fuel Tank

Capacity (L)

Hardwire Facility

Road Towable Silenced

Runtime (hrs) @ 3/4 load

X6043/A6043 400kVA Diesel 1000 Y - Y 19

X6048/A6048 500kVA Diesel 1000 Y - Y 14

X6055/A6055 800kVA Diesel 580 Y - Y 5

X6021/A6021 1000kVA Diesel 1600 Y Trailer Y 11

X6020/A6020 1250kVA Diesel 1600 Y Trailer Y 8

X6058/A6058 1260kVA Diesel 2000 Y Trailer Y 9.5

13hss.com/abird-apex 03456 00 14 85

Using state of the art machines with a robust rental specifi cation you get the very best reliability and technology available. 

With rental rates for standby, 50 hours, 60 hours and unlimited we have a package to suit your needs. All our generators are supplied with high viscosity oil and a spill kit which you can return if you don’t use it.

ASK U

S ABO

UT O

UR FU

EL M

ANAG

EMEN

T SER

VICE

S

All weights and measurements are approximate and correct at time of print. All weights and measurements are approximate and correct at time of print.

20kVA Silenced

Generator

30kVA Silenced

Generator

40kVA Silenced

Generator

60kVA Silenced

Generator

100kVA Silenced

Generator

Product Code X6035/A6035

X6040/A6040

X6044/A6044

X6050/A6050

X6022/A6022

kVA 20 30 40 60 100

Dimensions(L x W x H)

1.50 x 0.80x 1.33m

1.96 x 0.98 x 1.48m

1.96 x 0.98 x 1.48m

2.28 x 1.10 x 1.67m

2.97 x 1.13x 1.90m

Power 27A/18.5kW 41A/26kW 55A/36kW 83A/53kW 139A/80kW

Fuel tank capacity 75L 135L 135L 185L 180L

Fuel consumption@70% 3.80

L/hour@70% 4.60

L/hour@70% 6.60

L/hour@70% 10.6

L/hour

@70% 15.00 L/hour, @100% 21.40L/hour

dba 73@1m 73@1m 73@1m 74@1m 75@1m

Weight 670kg 1095kg 1155kg 1755kg 1685 kg

SILENCED GENERATORS

14 03456 00 14 85 hss.com/abird-apex

ASK US ABOUT OUR FUEL MANAGEMENT SERVICES

All weights and measurements are approximate and correct at time of print.

20kVA 30/40/60kVA

200kVA 250/300kVA

100/150/180kVA

150kVA Silenced

Generator

180kVA Silenced

Generator

200kVA Silenced

Generator

250kVA Silenced

Generator

300kVA Silenced

Generator

Product Code X6027/A6027

X6031/A6031

X6034/A6034

X6037/A6037

X6039/A6039

kVA 150 180 200 250 300

Dimensions(L x W x H)

2.97 x 1.13x 1.90m

3.56 x 1.26x 2.01m

3.56 x 1.26x 2.01m

3.83 x 1.23x 2.20m

4.04 x 1.42x 2.38m

Power208A/120kW

250A/144kW

278A/160kW

347A/ 200kW

417A/240kW

Fuel tank capacity 400L 400L 400L 450L 450L

Fuel consumption

@70% 23.20L/hour, @100% 33.10L/hour

@70% 28.20L/hour, @100% 40.20L/hour

@70% 28.30L/hour, @100% 40.50L/hour

@70% 46.10L/hour, @100% 65.80L/hour

@70% 49.20L/hour, @100% 70.20L/hour

dba 75@1m 75@1m 75@1m 75@1m 75@1m

Weight 2070 kg 2594 kg 2657 kg 3050 kg 5283 kg

SILENCED GENERATORS

15hss.com/abird-apex 03456 00 14 85

400kVA Silenced Generator

500kVA Silenced Generator

800kVA Silenced Generator

Product Code X6043/A6043 X6048/A6048 X6055/A6055

kVA 400 500 800

Dimensions(L x W x H)

4.85 x 2.00x 2.43m

4.85 x 2.00x 2.43m

5.35 x 2.00x 2.42m

Power 556A/320kW 695A/400kW 1112A/640kW

Fuel tank capacity 1000L 1000L 580L

Fuel consumption@70% 51.80

L/hour, @100% 74.00 L/hour

@70% 73.20 L/hour, @100% 104.50 L/hour

@70% 112.00L/hour, @100% 149.30 L/hour

dba 76@1m 76@1m 83@1m

Weight 5400 kg 6350 kg 8762 kg

All weights and measurements are approximate and correct at time of print.

500/800kVA400kVA

ASK U

S ABO

UT O

UR FU

EL M

ANAG

EMEN

T SER

VICE

SSILENCED GENERATORS

16 03456 00 14 85 hss.com/abird-apex

1000kVA Silenced Generators

1250kVA Silenced Generators

1260kVA Whisper Box Silenced

Generator

Product Code X6021/A6021 X6020/A6020 X6058/A6058

kVA 1000 1250 1260

Dimensions(L x W x H)

6.09 x 2.43x 3.27m

6.06 x 2.44x 2.90m

6.06 x 2.44x 2.90m

Power 1390A/800kW 1740A/1000kW 1752A/1008kW

Fuel tank capacity 1600L 1600L 2000L

Fuel consumption@70% 141.00L/hour, @100% 210.00 L/hour

@70% 185.00L/hour, @100% 254.00 L/hour

@70% 177.00L/hour, @100% 253.00 L/hour

dba 81@1m 83@1m 77@1m

Weight 13500 kg 20000 kg 20000kg

All weights and measurements are approximate and correct at time of print.

1260KVA WHISPER BOX1000/1250kVA

ASK US ABOUT OUR FUEL MANAGEMENT SERVICESSILENCED GENERATORS

17hss.com/abird-apex 03456 00 14 85

63AMP

125amp AMF Panel 400amp AMF Panel16-13amp Converter

With owned assets for cabling and power distribution we can provide a single source location to get the power from the machine to the required transformer, building, tool or to the right location, all delivered on one vehicle direct to you.

DISTRIBUTION BOARDS

ACCESSORIES

32AMP

125AMP400AMP

BOARDS & ACCESSORIES

18 03456 00 14 85 hss.com/abird-apex

Loadbank hire is an effective test for generators and UPS systems. Ideal for proving or maintaining your stanby power system without using the critical load as the test load.

258

Technical Specification

Code 25376

Item 1250kVA Silenced Generator

kVA 1250

Dimensions (L x W x H) 6.06 x 2.44 x 2.90m

Power 1740A/1074kW

Fuel tank capacity 1600L

Fuel consumption @70% 185.00 L/hour, @100% 254.00 L/hour

dba 83@1m

Weight 20000 kg

Technical Specification

Code 25308

Item 1000kVA Silenced Generator

kVA 1000

Dimensions (L x W x H) 6.09 x 2.43 x 3.27m

Power 1390A/800kW

Fuel tank capacity 1600L

Fuel consumption @70% 141.00 L/hour, @100% 210.00 L/hour

dba 81@1m

Weight 13500 kg

1260kVA Whisper Box Silenced Generator

Technical Specification

Code A6057

Item 1260kVA Whisper Box Silenced Generator

kVA 1260

Dimensions (L x W x H) 6.06 x 2.44 x 2.90m

Power 1752A/1008kW

Fuel tank capacity 2000L

Fuel consumption @70% 177.00 L/hour, @100% 253.00 L/hour

dba 77@1m

Weight 20000kg

1000kVA Silenced Generator

1250kVA Silenced Generator

• Add hybrid - see page 252

• Add hybrid - see page 252

• Add hybrid - see page 252

POW

ER

Gen

erat

ors

FOR HIRE RATES & DELIVERY INFORMATION

CLICKhss.com

CALL03457 28 28 28

VISITIN BRANCH

Check local stock availability at hss.com | Click, Collect & Drop Off Nationwide

Call 03457 66 77 77 to order. Special Terms & Conditions apply.

Call 03457 66 77 77 to order. Special Terms & Conditions apply.

Call 03457 66 77 77 to order. Special Terms & Conditions apply.

H0086_HSG0317325930_Power_258.indd 258 08/06/2017 21:15

259

125amp Distribution Board63amp Distribution Board

125amp AMF Panel 400amp AMF Panel16-13amp Converter

32amp Distribution Board

400amp Distribution Board

Distribution Boards

Loadbank hire is an effective test for generators and UPS systems. Ideal for proving or maintaining your standby power system without using the critical load as the test load.

Loadbanks

POW

ER

E

lectrical Accesso

ries

For hire rates contact your local branch or visit hss.com

Call 03457 66 77 77 to order. Special Terms & Conditions apply.

Call 03457 66 77 77 to order. Special Terms & Conditions apply.

H0086_HSG0317325930_Power_259.indd 259 08/06/2017 21:13

The new Lithium-ion Hybrid Lighting Tower comes complete with a 1500 rpm Kohler water cooled diesel engine and a lithium-ion battery pack, providing an excellent green solution. The Lithium hybrid uses just 0.7l of fuel per hour when re-charging the lithium battery pack.

LITHIUM-ION HYBRID LIGHTING TOWERS

SEE OUR FULL RANGE OF LIGHTING AT HSS.COM

LOADBANKS & LIGHTING

WE ALSO HIRE LIGHTING TOO.

19hss.com/abird-apex 03456 00 14 85

READY AND WAITING FOR YOUR CALL

TOOLS & EQUIPMENT

POWERED ACCESS

HEATING AND COOLING

MAINTENANCETRAINING

From Plant and Machinery, Storage and Welfare Units to Site Equipment.

IF YOU CAN HIRE IT, WE CAN PROVIDE IT

08457 66 77 77

READY AND WAITING FOR YOUR CALL

With a huge range of tools and equipment ready for collection or delivery, HSS has the right kit at a great price for small DIY jobs in the home to larger construction projects. Call 03457 28 28 28 or visit hss.com

THE KIT YOU NEED WHEREVER, WHENEVER

With 50 training centres across the UK, HSS Training offers industry recognised courses that will give your workforce the technical know-how to operate equipment safely. Call 03457 66 77 99 or visit hsstraining.com

GET FULLY QUALIFIED OVER 200 COURSES

Specialising in large chiller and boiler ranges, All Seasons Hire offer a complete installation service for a comprehensive range of air conditioning, cooling and heating equipment. Call 0800 082 8001 or visit allseasonshire.com

HEATING & COOLING SPECIALISTS

We’re here to support you in all aspects of your power needs, from the initial site survey through to on-going management and emergency maintenance. Based across the UK our specialist depots, engineers and service teams are ready and waiting to support your total power solution.

LOCAL DEPOTSOur dedicated local power generation experts are here to support you throughout the entire hire process wherever your site or project is, from project planning to project completion.

AREA SALES & TECHNICAL SALES SUPPORTOur Area Sales Manager and Technical Sales Managers can provide expert advice on all aspects of your project from; site surveys, contingency planning, cable and distribution selection and fuel management services.

SERVICE SUPPORT Our local service centres provide leading levels of service and support right throughout your project - 24 hours a day, 365 days of the year.

22 03456 00 14 85 hss.com/abird-apex

EAST LONDONTel: 02088 00 88 [email protected]

WEST LONDONTel: 01895 [email protected]

SOUTH COASTTel: 02392 [email protected]

WALESTel: 01495 [email protected]

EAST MIDLANDSTel: 01536 [email protected]

NORTH WESTTel: 01744 [email protected]

NORTH EASTTel: 01642 [email protected]

SCOTLAND WESTTel: 08455 19 20 [email protected]

SCOTLAND EASTTel: 01224 [email protected]

NORTHERN IRELANDTel: 08000 23 23 [email protected]

EAST MIDLANDS

North East

Wales

East Midlands

ScotlandWest

ScotlandEast

NorthernIreland

North West

East London

West London

South Coast

You can hire nationally by contacting one of your local depots throughout the UK.

WHEREVER YOU ARE, WE CANDELIVER

FULL DEPOT LISTING PAGES 22-23

Safety / Value / Availability / Support

@abirdhire

Safety / Value / Availability / Support

03456 00 14 85hss.com/abird-apex