030 Vios Install Sea
Transcript of 030 Vios Install Sea
-
8/8/2019 030 Vios Install Sea
1/33
Copyright IBM Corporation 2007 Course materials may not be reproduced in whole or in part without written permission.
Installing the VIO Server LPAR from NIMQPS01 IBM System P APV 030
-
8/8/2019 030 Vios Install Sea
2/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 2
IBM System p Advanced POWER Virtualization
Defining VIO Server Partition
Objectives: Describe how to activate partition to go to SMS mode
SMS mode is used for installing AIX and Linux
Describe how to setup SMS menus for network NIM install
Install the VIO server LPAR from NIM
Select language for install Select disks to be used for install
-
8/8/2019 030 Vios Install Sea
3/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 3
IBM System p Advanced POWER Virtualization
Partition Definition Handout Use your handout
VIO hostname
VIO IP
VIO Install NIM Server
NetmaskGateway
Spanning Tree
Adapter speed
-
8/8/2019 030 Vios Install Sea
4/33 Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 4
IBM System p Advanced POWER Virtualization
Select the Partition(s) to Activate
1. ODD Right click
on VIO1 partition
1. EVEN Right clickon VIO2 partition
2. Select Activate
from popup window.
-
8/8/2019 030 Vios Install Sea
5/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 5
IBM System p Advanced POWER Virtualization
Select the Partition Profile you want to activate
default
4. Select
Open a terminal window..
5. Select
Advanced
3. Select
Desired default profile
Do not click OK yet
-
8/8/2019 030 Vios Install Sea
6/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 6
IBM System p Advanced POWER Virtualization
Select Boot Mode for the Partition
6. Select
Boot Mode Dropdown
7. Select SMS
-
8/8/2019 030 Vios Install Sea
7/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 7
IBM System p Advanced POWER Virtualization
Exit advanced menu and start partition
Partition activation starts
8. Click OK
default
9. Click OK
-
8/8/2019 030 Vios Install Sea
8/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 8
IBM System p Advanced POWER Virtualization
Activation ends and installation begins
Observe Activate Windows
Click Show Details if desired
To select this console as the active console press 0
Press 0 if prompted
-
8/8/2019 030 Vios Install Sea
9/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 9
IBM System p Advanced POWER Virtualization
Last chance to enter SMS mode
IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM
IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM
IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM
IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM
IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM IBM
1 = SMS Menu 5 = Default Boot List
8 = Open Firmware Prompt 6 = Stored Boot List
Memory Keyboard Network SCSI Speaker
If you had not specified to boot to SMS, you would need to wait for thisscreen to pop up and then hit 1 repeatedly as the bottom line is displaying
This only appears for a couple of seconds, so it is very easy to miss it
It is much more convenient to use the SMS override from the advanced
activation menu
-
8/8/2019 030 Vios Install Sea
10/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 10
IBM System p Advanced POWER Virtualization
SMS Main Menu => Select Remote IPL
Main Menu
1. Select Language
2. Setup Remote IPL (Initial Program Load)
3. Change SCSI Settings
4. Select Console
5. Select Boot Options
Type menu item number and press Enter or select Navigation key: 2
-------------------------------------------------------------------------------------------NIC Adapters
Device Location Code Hardware
Address1. Interpartition Logical LAN U9111.520.1007F4F-C2-T1 2646c00050022. Interpartition Logical LAN U9111.520.1007F4F-C3-T1 2646c0005003
3. Port 1 IBM 2 PORT 10/100 U787A,001,DPM1672-P1-T5 00096beb8122
4. Port 2 IBM 2 PORT 10/100 U787A,001,DPM1672-P1-T6 00096beb8122
Type menu item number and press Enter or select Navigation key: 3
Type 2 and press Enter
To select
Setup Remote IPL
Type 3 and press Enter
Adapter on Port 1
Do NOT select
Interpartition Logical LAN
-
8/8/2019 030 Vios Install Sea
11/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 11
IBM System p Advanced POWER Virtualization
Select set IP Parameters
Network Parameters
Port 1 IBM 2 PORT 10/100 U787A,001,DPM1672-P1-T5
1. IP Parameters
2. Adapter Configuration3. Ping Test
4. Advanced Setup: BOOTP
Type menu item number and press Enter or select Navigation key: 1
-------------------------------------------------------------------------------------------
Type 1 and press Enter
To select
IP Parameters
-
8/8/2019 030 Vios Install Sea
12/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 12
IBM System p Advanced POWER Virtualization
Set the Client IP Address
IP Parameters
Port 1 IBM 2 PORT 10/100 U787A,001,DPM1672-P1-T5
1. Client IP Address [000.000.000.000]
2. Server IP Address [000.000.000.000]3. Gateway IP Address [000.000.000.000]
4. Subnet Mask [255.255.255.000]
Type menu item number and press Enter or select Navigation key: 1
-------------------------------------------------------------------------------------------
X to Abort or Enter Client IP Address: 10.31.197.XX
Type 1 and press Enter
EnterVIO IP addressFrom student worksheet
And press Enter
-
8/8/2019 030 Vios Install Sea
13/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 13
IBM System p Advanced POWER Virtualization
Set the NIM Server IP Address
IP Parameters
Port 1 IBM 2 PORT 10/100 U787A,001,DPM1672-P1-T5
1. Client IP Address [10.31.197.XX]]
2. Server IP Address [000.000.000.000]3. Gateway IP Address [000.000.000.000]
4. Subnet Mask [255.255.255.000]
Type menu item number and press Enter or select Navigation key: 2
-------------------------------------------------------------------------------------------
X to Abort or Enter Client IP Address: 10.31.197.164
Type 2 and press Enter
Enter IP address
of NIM server
10.31.197.164
And press Enter
-
8/8/2019 030 Vios Install Sea
14/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 14
IBM System p Advanced POWER Virtualization
Set the Subnet Mask
IP Parameters
Port 1 IBM 2 PORT 10/100 U787A,001,DPM1672-P1-T5
1. Client IP Address [10.31.197.XX]]
2. Server IP Address [10.31.197.164]3. Gateway IP Address [000.000.000.000]
4. Subnet Mask [255.255.255.000]
Type menu item number and press Enter or select Navigation key: 4
-------------------------------------------------------------------------------------------
X to Abort or Subnet mask: 255.255.240.0
Type 4 and press Enter
Enter subnet mask
255.255.240.0
And press Enter
-
8/8/2019 030 Vios Install Sea
15/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 15
IBM System p Advanced POWER Virtualization
Verify settings
IP Parameters
Port 1 IBM 2 PORT 10/100 U787A,001,DPM1672-P1-T5
1. Client IP Address [10.31.197.XX]]
2. Server IP Address [10.31.197.164]3. Gateway IP Address [000.000.000.000]
4. Subnet Mask [255.255.240.000]
Type menu item number and press Enter or select Navigation key: 4
Press Esc Once
Verify
No XX | No XX
01 13 | 02 17
03 23 | 04 27
05 33 | 06 37
07 43 | 08 47
09 53 | 10 57
11 63 | 12 67
13 73 | 14 77
15 83 | 16 87
17 93 | 18 97
19 103 | 20 107
21 113 | 22 117
23 123 | 24 127
25 133 | 26 137
27 143 | 28 147
29 153 | 30 157
IBM S t Ad d POWER Vi t li ti
-
8/8/2019 030 Vios Install Sea
16/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 16
IBM System p Advanced POWER Virtualization
Enter 2 to set Adapter Configuration
Network Parameters
Port 1 IBM 2 PORT 10/100 U787A,001,DPM1672-P1-T5
1. IP Parameters
2. Adapter Configuration3. Ping Test
4. Advanced Setup: BOOTP
Type menu item number and press Enter or select Navigation key: 2
-------------------------------------------------------------------------------------------
Type 2 and press Enter
To select
Adapter Configuration
IBM S t Ad d POWER Vi t li ti
-
8/8/2019 030 Vios Install Sea
17/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 17
IBM System p Advanced POWER Virtualization
Enter 1 to set Speed Duplex
Adapter Configuration
Port 1 IBM 2 PORT 10/100 U787A,001,DPM1672-P1-T5
1. Speed,Duplex
2. Spanning Tree Enabled3. Protocol
Type menu item number and press Enter or select Navigation key: 1
-------------------------------------------------------------------------------------------
Spanning Tree Enabled
Port 1 IBM 2 PORT 10/100 U787A,001,DPM1672-P1-T5
1. auto, auto ( rj45 )>
-
8/8/2019 030 Vios Install Sea
18/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 18
IBM System p Advanced POWER Virtualization
Enter 2 to set Spanning Tree Enable to No
Adapter Configuration
Port 1 IBM 2 PORT 10/100 U787A,001,DPM1672-P1-T5
1. Speed,Duplex
2. Spanning Tree Enabled3. Protocol
Type menu item number and press Enter or select Navigation key: 2
-------------------------------------------------------------------------------------------
Spanning Tree Enabled
Port 1 IBM 2 PORT 10/100 U787A,001,DPM1672-P1-T5
1. Yes
2. No
Type 2 and press Enter
To select
Spanning Tree Enabled
Type 2 and press EnterforNo
Press Esc twice
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
19/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 19
IBM System p Advanced POWER Virtualization
Enter 3 to set Ping Test
Network Parameters
Port 1 IBM 2 PORT 10/100 U787A,001,DPM1672-P1-T5
1. IP Parameters
2. Adapter Configuration3. Ping Test
4. Advanced Setup: BOOTP
Type menu item number and press Enter or select Navigation key: 3
-------------------------------------------------------------------------------------------
Type 3 and press Enter to select Ping Test
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
20/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 20
IBM System p Advanced POWER Virtualization
Verify configuration and execute ping test
Ping Test
Interpartition Logical LAN: U9111.520.1007F4F-V7-C5-T1
Speed, Duplex: auto.auto
Client IP Address: 10.31.197.XX
Server IP Address: 10.31.197.164
Gateway IP Address: 000.000.000.000
Subnet Mask: 255.255.240.0
Protocol: Standard
Spanning Tree Enabled: 0
Connector type: rj45
1. Execute ping test
Type menu item number and press Enter or select Navigation key: 1
Type 1 and press Enter to
Execute Ping Test
verify PING SUCCESS
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
21/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 21
IBM System p Advanced POWER Virtualization
Enter M to return to Main Menu
Network Parameters
Interpartition Logical LAN: U9111.520.1007F4F-V7-C5-T1
1. IP Parameters
2. Adapter Configuration
3. Ping Test
4. Advanced Setup: BOOTP
Type menu item number and press Enter or select Navigation key: M
-------------------------------------------------------------------------------------------
Type M to return to Main Menu
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
22/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 22
IBM System p Advanced POWER Virtualization
Select Boot Options -> Select Install/Boot Device
Main Menu
1. Select Language
2. Setup Remote IPL (Initial Program Load)
3. Change SCSI Settings4. Select Console
5. Select Boot Options
Type menu item number and press Enter or select Navigation key: 5
-------------------------------------------------------------------------------------------
Multiboot
1. Select Install/Boot Device
2. Configure Boot Device Order3. Mutliboot Startup
Type menu item number and press Enter or select Navigation key: 1
Type 5 and press Enter
To select
Select Boot Options
Type 1 and press Enter
Select Install/Boot Device
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
23/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 23
y p
Select Device Type Network => Choose ethernet slot
Select Device Type1. Diskette
2. Tape
3. CD/DVD
4. IDE
5. Hard Drive6. Network
7. List all devices
Type menu item number and press Enter or select Navigation key: 6
-------------------------------------------------------------------------------------------
Select DeviceDevice Current Device
Number Position Name1. 2 Virtual Ethernet
( loc=U9111.520.1007F4F-V5-C2-T1
2. 2 Virtual Ethernet
( loc=U9111.520.1007F4F-V5-C3-T1
3. - Ethernet
( loc=U787A.001.DPM1672-P1-T5
4. - Ethernet
( loc=U787A.001.DPM1672-P1-T6
Type menu item number and press Enter or select Navigation key: 3
Type 6 and press Enter
To select
Network
Type 3 and press Enter
forPort 1 Ethernet
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
24/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 24
y p
Normal Mode Boot => Exit SMS
Ethernet
( loc=U4787A.001.DPM1672-P1-T5
1. Information
2. Normal Mode Boot3. Service Mode Boot
Type menu item number and press Enter or select Navigation key: 2
-------------------------------------------------------------------------------------------
Are you sure you want to exit System Management Services?
1. Yes
2. No
Type menu item number and press Enter or select Navigation key: 1
Type 2 and press Enter
To select
Normal Mode Boot
Type 1 and press Enter
forYes
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
25/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 25
The Partition(s) boot from BOOTP/TFTP
BOOTP: client IP = 10.31.197.XX
BOOTP: client HW addr = 0 9 6b eb 81 22
BOOTP: gateway IP = 0.0.0.0
BOOTP: device /pci@80000000200000002/pci@2,4/ethernet@1
BOOTP: loc-code U787A.001.DPM1672-P1-T5
BOOTP R = 1 BOOTP S=2
FILE: /tftpboot/sys01_vio1
BOOTP: chose-network-type = ethernet,auto, rj45,auto
BOOTP server IP = 10.31.197.164
BOOTP: requested filename =BOOTP: client IP = 10.31.197.XX
BOOTP: client HW addr = 0 9 6b eb 81 22
BOOTP: gateway IP = 0.0.0.0
BOOTP: device /pci@80000000200000002/pci@2,4/ethernet@1
BOOTP: loc-code U787A.001.DPM1672-P1-T5
BOOTP R = 1 BOOTP S = 2
FILE: /tftpboot/sys01_vio1icmp 5 : redirect
Packet Count 3100
If BOOTP fails
Notify instructor now
Look for FILE name
Watch packet count
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
26/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 26
Define System Console / English Install
********* Please define the System Console ********
Type a 1 and press Enter to use this terminal as the system console
>>> Type 1 and press Enter to have English during install
Type the number of your choice and press Enter. Choice is indicated by >>>
>>> 1 Start Install Now with Default Settings2 Change/Show Installation Settings and Install
3 Start Maintenance Mode for System Recover
>
Type 1 and press EnterforSystem Console
Type 1 and press Enter
forEnglish
Type 2 to select
Change/Show
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
27/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 27
Verify the Disk Selection
Installation and Settings
Either Type 0 and press Enter to install with current settings, or type the
number of the setting you want to change and press Enter
Setting: Current Choice(s):
1. Disk(s) where you want to install ...hdisk0...
Use Maps ....................No
2. Shrink File Systems .................No
3. Import User Volume Groups ...........No
4. Recover Devices .....................No
>>> 0 Install with the settings listed above
88 Help ?
99 Previous Menu
>>> Choice [0]: 1
Type 1 and Enter
hdisk0 show more than 1 disk
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
28/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 28
Make sure both disks are selected
Change Disk(s) Where You Want to Install
Type one or more numbers for the disk(s) to be used for installation and press
Enter. To cancel a choice, type the corresponding number and Press Enter.
At least one bootable disk must be selected. The current choice is indictedby >>>.
Name Location Code Size(MB) VG Status Bootable No
>>> 1 hdisk0 03-08-00-3,0 70006 rootvg Yes No
2 hdisk1 03-08-00-4,0 70006 rootvg Yes No
>>> 0 Continue with choices indicated above55 More Disk Options
66 Disks not known to Base Operating System Installation
77 Display Alternative Disk Attributes
88 Help ?99 Previous Menu
>>> Choice [0]: 77 .
Type 77 and press Enter
>>> shows selected disks
Type number to select/unselect
Install to both disks
Press 2 if hdisk1 isnot selected.
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
29/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 29
Make sure both disks are selected
View Physical Volume Identifier
Type one or more numbers for the disk(s) to be used for installation and press
Enter. To cancel a choice, type the corresponding number and Press Enter.
At least one bootable disk must be selected. The current choice is indictedby >>>.
Name Physical Volume Identifier
>>> 1 hdisk0 00c07f6fbc7639c8
>>> 2 hdisk1 00c07f6f5a0a2e18
>>> 0 Continue with choices indicated above55 More Disk Options
66 Disks not known to Base Operating System Installation
77 Display Alternative Disk Attributes
88 Help ?99 Previous Menu
>>> Choice [0]: 77 .
Type 77 Enter
PVID indicates disk was used
before.
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
30/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 30
Make sure both disks are selected
View Physical Volume Identifier
Type one or more numbers for the disk(s) to be used for installation and press
Enter. To cancel a choice, type the corresponding number and Press Enter.
At least one bootable disk must be selected. The current choice is indictedby >>>.
Name Device Adapter Connection Location
or Physical Location Code
1 hdisk0 U787A.001.DPM166C-P1-T10-L3-L0
2 hdisk1 U787A.001.DPM166C-P1-T10-L4-L0
>>> 0 Continue with choices indicated above55 More Disk Options66 Disks not known to Base Operating System Installation
77 Display Alternative Disk Attributes
88 Help ?99 Previous Menu
>>> Choice [0]:.
Press Enter
View SCSI adapter location
Example slot T10
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
31/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 31
Verify the Disk Selection
Installation and Settings
Either Type 0 and press Enter to install with current settings, or type the
number of the setting you want to change and press Enter
Setting: Current Choice(s):
1. Disk(s) where you want to install ...hdisk0
Use Maps ....................No
2. Shrink File Systems .................No
3. Import User Volume Groups ...........No
4. Recover Devices .....................No
>>> 0 Install with the settings listed above
88 Help ?
99 Previous Menu
>>> Choice [0]: 0
Type 0 and Enter
Press Enter on next prompts
to begin install
Last chance to back out before
writing to the disks
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
32/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 32
The system will reboot once installed
Installing Base Operating System
Please wait. . .
Approximate Elapsed time
% tasks complete (in minutes)
96 21 Creating boot image
The system will reboot after the installation and perform post-install tasksdefined on the NIM server (firstboot scripts, etc)
Monitor installation progress
IBM System p Advanced POWER Virtualization
-
8/8/2019 030 Vios Install Sea
33/33
Copyright IBM Corporation 2007
IBM System p
QPS01 030 VIOS Install SEA 33
Summary
Described how to activate partition to go to SMS mode
SMS mode is used for installing AIX and Linux
Described how to setup SMS menus for network NIM install
Installed the VIO server LPAR from NIM Select language for install
Select disks to be used for install