1/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EVFEVF
Ex Lighting
LIGHTING FIXTURES FORFLUORESCENT TUBE LAMPS
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)Classication: Group II - Category 2G 2D
LIGHTING FIXTURES
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex d IIC T5/T4
II 2 D Ex tD A21 T100C / T135C
1Ex d IIC T5/T4
DIP A21 TA(100135)C
1Ex d IIC T5/T4
DIP A21 TA(100135)C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. ISSEP 02 ATEX 043 POCC IT. 05.B02536 No. 07/43-269
RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-1
51330.9-99 ( 60079-10-95)
51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
EMERGENCY UNIT
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex d IIC T6
II 2 D Ex d tD A21 T85C
1Ex d IIC T6
DIP A21 TAT85C
1Ex d IIC T6
DIP A21 TAT85C
INSTALLATION ZONA 1 / 2 - ZONA 21 / 22 ZONA 1 / 2 - ZONA 21 / 22 ZONA 1 / 2 - ZONA 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 08 ATEX 018 POCC IT. 05.B02537 No. 07/43-269
RULES OF COMPLIANCEEN 60079-0; EN 60079-1;
EN 61241-0; EN 61241-1;
51330.9-99 ( 60079-10-95)
51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
Mechanical characteristics
Body marine grade copper free aluminium (control gear & emergency unit)
Tubes high-temperature resistant borosylicate glass tube
Painting external epoxy powders grey RAL-9006colour
Screws external stainless steel
Gaskets nbr rubber
Reectors white stove enamelled sheet steel
Cable entry 3/4 NPTsize threaded
Electrical characteristicsPower supply elettronic ballast 220V/240v - 50/60Hz (p.f.corrected - cos 0,98)
Lampholders bi-pin G13 cap
Internal wiring high-temperature resistant silicon rubber insulation cables
Emergency unit emergency unit composed of inverter charger and ni-cd battery pack 4A/h 6V. autonomy from 60 to 120min.Led power-on indicating lamp provided
Feam Catalogue 01- 1
ON REQUEST ACCESSORIES:
Pole mounting kit complete with stainless steel hardware
Ceiling mounting kit complete with stainless steel hardware
Pendant mounting kit complete with stainless steel hardware
Wall/Structure mounting kit complete with stainless steel hardware
Galvanized steel wire protection guard
Stainless steel wire protection guard
Stainless steel reectors
External painting colour on request
Electronic ballast with voltage supply different than standard
Ni-Cd Battery pack 7A/h 6V for Emergency Unit with Autonomy more than 150min
-
8/11/2019 01_FEAM_N
2/94YOUR PARTNER FOR SAFETY
Since 1961
EVF
C
D
A
3/4B
D
A
3/4B
C
B
A
8MA 8MA
8MA 8MA
EVF18ELME 1 x 18W T5 T 100C
G131 x 3/4
4.8 V - 4Ah 2h C T4 T 135C 1 x 1/2
EVF36ELME 1 x 36W T5 T 100C
G131 x 3/4
4.8 V - 4Ah 2h C T4 T 135C 1 x 1/2
EVF58ELME 1 x 58W T5 T 100C
G131 x 3/4
4.8 V - 4Ah 2h C T4 T 135C 1 x 1/2
EVF18ELBE 2 x 18W T5 T 100C
G131 x 3/4
4.8 V - 4Ah 2h D T4 T 135C 1 x 1/2
EVF36ELBE 2 x 36W T5 T 100C
G131 x 3/4
4.8 V - 4Ah 2h D T4 T 135C 1 x 1/2
EVF58ELBE 2 x 58W T5 T 100C
G131 x 3/4
4.8 V - 4Ah 2h D T4 T 135C 1 x 1/2
EVF18EL 1 x 18W T5 T 100C
G13 2 x 3/4 - - A
T4 T 135C
EVF36EL 1 x 36W T5 T 100C
G13 2 x 3/4 - - A T4 T 135C
EVF58EL 1 x 58WT5 T 100C
G13 2 x 3/4 - - A T4 T 135C
EVF18BEL 2 x 18W T5 T 100C
G13 2 x 3/4 - - B T4 T 135C
EVF36BEL 2 x 36WT5 T 100C
G13 2 x 3/4 - - B T4 T 135C
EVF58BEL 2 x 58WT5 T 100C
G13 2 x 3/4 - - B T4 T 135C
2 - Feam Catalogue 01
Ex Lighting
EVF Technical data
EVF Technical features
Reference details
EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 220V/240V - 50/60Hz
FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 220V/240V - 50/60Hz
CODE LAMPTEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)LAMPHOLDER CABLE ENTRY
EMERGENCY
UNITAUTONOMY DETAIL
CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
EVF18EL 1000 96 95 602 4,50 2 x 3/4 A
EVF36EL 1600 96 95 1202 5,70 2 x 3/4 A
EVF58EL 1900 96 95 1490 7,00 2 x 3/4 A
EVF18BEL 1000 200 95 602 9,00 2 x 3/4 B
EVF36BEL 1600 200 95 1202 12,20 2 x 3/4 B
EVF58BEL 1900 200 95 1490 14,70 2 x 3/4 B
-
8/11/2019 01_FEAM_N
3/94YOUR PARTNER FOR SAFETY
Since 1961
EVF
45
170
45 45108
170
156
156
100
100
50
128
45
3/4
273
273
128
45
50
100
50
CD
A
3/4
3/41 - 1/2
B
C
D
A
3/4
B
C
D
1 - 1/2
3/4
EVF18ELME 1000 222 379 602 10,00 1 x 3/4 / 1 x 1/2 C
EVF36ELME 1600 222 379 1202 12,00 1 x 3/4 / 1 x 1/2 C
EVF58ELME 1900 222 379 1490 14,00 1 x 3/4 / 1 x 1/2 C
EVF18ELBE 1000 287 265 602 16,00 1 x 3/4 / 1 x 1/2 D
EVF36ELBE 1600 287 265 1202 19,00 1 x 3/4 / 1 x 1/2 D
EVF58ELBE 1900 287 265 1490 21,00 1 x 3/4 / 1 x 1/2 D
Feam Catalogue 01- 3
Ex Lighting
EVF Technical features
EVF Installation and mounting details
Wall/structure mountingPole mounting
Assemblig detail with pole (typical)
Pendant mountingCeiling mounting
type 2type 1
type 3 type 4
CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
Reference details
-
8/11/2019 01_FEAM_N
4/94YOUR PARTNER FOR SAFETY
Since 1961
EVF
EVF18BEL EVF36BEL EVF58BEL
4 - Feam Catalogue 01
Ex Lighting
EVF Polar diagrams photometric data
EVF On request accessories
GABBIAEVFF18 18W SIZE GALVANIZED STEEL WIRE PROTECTION GUARD GALVANIZED STEEL
GABBIAEVFF36 36W SIZE GALVANIZED STEEL WIRE PROTECTION GUARD GALVANIZED STEELGABBIAEVFF58 58W SIZE GALVANIZED STEEL WIRE PROTECTION GUARD GALVANIZED STEEL
GABBIAEVFF18IX 18W SIZE STAINLESS STEEL WIRE PROTECTION GUARD STAINLESS STEEL
GABBIAEVFF36IX 36W SIZE STAINLESS STEEL WIRE PROTECTION GUARD STAINLESS STEEL
GABBIAEVFF58IX 58W SIZE STAINLESS STEEL WIRE PROTECTION GUARD STAINLESS STEEL
D18IX 18W SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL
D36IX 36W SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL
D58IX 58W SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL
20301.0151 SINGLE LAMP CEILING MOUNTING KIT C/W HARDWARE TYPE 1 ALUM. LIGHT ALLOY
20301.0152 TWIN LAMP CEILING MOUNTING KIT C/W HARDWARE TYPE 1 ALUM. LIGHT ALLOY
20301.0153 SINGLE LAMP POLE MOUNTING KIT (SIZE 1 DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL
20301.0155 SINGLE LAMP POLE MOUNTING KIT (SIZE 1 1/2 DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL
20301.0156 TWIN LAMP POLE MOUNTING KIT (SIZE 1 1/2 DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL
20301.0157 SINGLE LAMP POLE MOUNTING KIT (SIZE 2 DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL
20301.0158 TWIN LAMP POLE MOUNTING KIT (SIZE 2 DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL
20302.0128 SINGLE LAMP WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL
20302.0128 TWIN LAMP WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL
20301.0165 SINGLE LAMP PENDANT MOUNTING KIT C/W HARDWARE TYPE 2 GALVANIZED STEEL
20301.0165 TWIN LAMP PENDANT MOUNTING KIT C/W HARDWARE TYPE 2 GALVANIZED STEEL
REMARK:Due to the development of the national and international specications and of the technology, the above technical characteristicsshowed on this bulletin can be considered as binding on our conrmation only.
CODE DESCRIPTION INSTALLATION MATERIAL
-
8/11/2019 01_FEAM_N
5/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EVACEVAC
ON REQUEST ACCESSORIES:
Ceiling mounting AISI 316L stainless steel kit complete with stainless steel hardware
Pendant mounting AISI 316L stainless steel kit complete with stainless steel hardware
Pole mounting kit 1 1 1/2 2 dia. complete with stainless steel hardware
Wall/Structure mounting kit complete with stainless steel hardware
Galvanized steel wire protection guard
Stainless steel wire protection guard
White stove enamelled aluminium reectors
Stainless steel reectors
External painting colour on request
Control gear with voltage supply different than standard
Threaded cable entry different than standard
Mechanical characteristics
Body marine grade copper free aluminium (control gear & lamp body)
Globe high-temperature resistant borosylicate glass
Painting external epoxy powders grey RAL-9006colour
Screws external stainless steel
Gaskets silicon rubberCable entry 3/4 NPTsize threaded
Installation swivel bracket AISI 316L stainless steel
Electrical characteristics
Power supply (prc) conventional ballast 230V - 50Hz (p.f. corrected - cos 0,95)
Lampholders porcelain E27/E40 size
Internal wiring high-temperature resistant silicon rubber insulation cables
Terminals suitable up to 4mm/sq cables
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)Classifcation:Group II - Category 2G 2D
LIGHTING FIXTURESFOR INCANDESCENT ANDDISCHARGE LAMPS
LIGHTING FIXTURE / CONTROL GEAR
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex d IIC T6/T2
II 2 D Ex tD A21 T80C / T290C
1Ex d IIC T6 (T5T2) X
DIP A21 TA(80290)C
1Ex d IIC T6 (T5T2) X
DIP A21 TA(80290)C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 01 ATEX 0054X POCC IT. 05.B02536 No. 07/43-269
RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-1
51330.9-99 ( 60079-10-95)
51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
Feam Catalogue 01 - 5
Ex Lighting
-
8/11/2019 01_FEAM_N
6/94YOUR PARTNER FOR SAFETY
Since 1961
EVAC
6 - Feam Catalogue 01
Ex Lighting
EVAC Technical data
CODE LAMPTEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)
LAMPHOLDER
SIZECABLE ENTRY SIZE DETAIL
LIGHTING FIXTURE FOR HALOGEN LAMP - POWER SUPPLY 230V-50Hz
LIGHTING FIXTURE FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V-50Hz
LIGHTING FIXTURE FOR METAL HALIDE LAMP - POWER SUPPLY 230V-50Hz
LIGHTING FIXTURE FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V-50Hz
LIGHTING FIXTURE FOR BLENDED LIGHT LAMP - POWER SUPPLY 230V-50Hz
EVAC101 100 W T4 T 130C E-27 1 x 3/4" A
EVAC100 100 W T4 T 130C E-27 2 x 3/4" B
EVAC201 200 WT4
T3
T 130C
T 195CE-27 1 x 3/4" A
EVAC200 200 WT4
T3
T 130C
T 195CE-27 2 x 3/4" B
EVAC301 300 WT4
T3
T 130C
T 195CE-40 1 x 3/4" A
EVAC300 300 WT4
T3
T 130C
T 195CE-40 2 x 3/4" B
EVAC501 500 W T3 T 195C E-40 1 x 3/4" A
EVAC500 500 W T3 T 195C E-40 2 x 3/4" B
EVAC100-E2025 W
20 W
T5
T4
T 95C
T 130C
E-14 + Ba-15s 2 x 3/4" B
EVAC101-100H 100 W T4 T 130C E-27 1 x 3/4" A
EVAC100-100H 100 W T4 T 130C E-27 2 x 3/4" B
EVAC201-150H 150 W T1 T 130C E-27 1 x 3/4" A
EVAC200-150H 150 W T2 T 130C E-27 2 x 3/4" B
EVAC301-250H 250 WT4
T3
T 130C
T 195CE-27 1 x 3/4" A
EVAC300-250H 250 WT4
T3
T 130C
T 195CE-27 2 x 3/4" B
EVAC101-80HG 80 W T4 T 130C E-27 2 x 3/4 / 1 x 1-1/2 C
EVAC201-125HG 125 W T3 T 195C E-27 2 x 3/4 / 1 x 1-1/2 C
EVAC301-250HG 250 W T3 T 195C E-40 2 x 3/4 / 1 x 1-1/2 C
EVAC501-250HG 250 W T4 T 130C E-40 2 x 3/4 / 1 x 1-1/2 C
EVAC501-400HG 400 W T3 T 195C E-40 2 x 3/4 / 1 x 1-1/2 C
EVAC101-100MH 100 W T4 T 130C E-27 2 x 3/4" / 1 x 1-1/2" C
EVAC301-150MH 150 WT4
T3
T 130C
T 195CE-27 2 x 3/4" / 1 x 1-1/2" C
EVAC301-250MH 250 W T3 T 195C E-40 2 x 3/4" / 1 x 1-1/2" C
EVAC501-400MH 400 W T3 T 195C E-40 2 x 3/4" / 1 x 1-1/2" C
EVAC101-70HPNA 70 W T4 T 130C E-27 2 x 3/4" / 1 x 1-1/2" C
EVAC301-150HPNA 150 W T4 T 130C E-40 2 x 3/4" / 1 x 1-1/2" C
EVAC301-250HPNA 250 WT3
T2
T 195C
T 290C
E-40 2 x 3/4" / 1 x 1-1/2" C
EVAC501-400HPNA 400 W T3 T 195C E-40 2 x 3/4" / 1 x 1-1/2" C
EVAC201-160MLL 160 W T3 T 195C E-27 2 x 3/4" / 1 x 1-1/2" A
EVAC200-160MLL 160 W T3 T 195C E-27 2 x 3/4" / 1 x 1-1/2" B
EVAC301-250MLL 250 W T3 T 195C E-40 2 x 3/4" / 1 x 1-1/2" A
EVAC300-250MLL 250 W T3 T 195C E-40 2 x 3/4" / 1 x 1-1/2" B
LIGHTING FIXTURE FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz
-
8/11/2019 01_FEAM_N
7/94YOUR PARTNER FOR SAFETY
Since 1961
EVAC
B C
3/4
D
E
A
80 6060
8.5
180200
8060
16
3
A
E
D
B C
2X3/4
A
D
E
B C
200
30
1
0
2828
192
51-1/2
A B
C
EVAC101 150 270 240 145 280 3,50 1 x 3/4 A
EVAC100 150 270 240 145 280 3,50 2 x 3/4 B
EVAC201 175 290 270 170 345 4,00 1 x 3/4 A
EVAC200 175 290 270 170 345 4,00 2 x 3/4 BEVAC301 200 390 330 190 402 7,00 1 x 3/4 A
EVAC300 200 390 330 190 402 7,00 2 x 3/4 B
EVAC501 260 420 395 255 515 10,00 1 x 3/4 A
EVAC500 260 420 395 255 515 10,00 2 x 3/4 B
EVAC101-..HG
EVAC101-..HPNA 225 545 515 145 280 9,002 x 3/4
C
EVAC101-..MH1 x 1-1/2
EVAC201-..HG 225 565 545 170 345 9,50 2 x 3/4
C
1 x 1-1/2
EVAC301-..HG
EVAC301-..HPNA 225 665 640 190 402 12,002 x 3/4
C
EVAC301-..MH1 x 1-1/2
EVAC501-..HG
EVAC501-..HPNA 225 695 670 255 515 15,502 x 3/4
C
EVAC501-..MH1 x 1-1/2
Feam Catalogue 01- 7
Ex Lighting
EVAC Technical features
Reference details Reference details
Reference details
CODE A [mm] B [mm] C [mm] D [mm] E [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
CODE A [mm] B [mm] C [mm] D [mm] E [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
-
8/11/2019 01_FEAM_N
8/94YOUR PARTNER FOR SAFETY
Since 1961
EVAC
237
180
58283
275
54
16
8 - Feam Catalogue 01
Ex Lighting
EVAC Installation and mounting details
Ceiling mounting
Pendant mounting
Wall/structure mounting
type 1
type 2
type 3
-
8/11/2019 01_FEAM_N
9/94YOUR PARTNER FOR SAFETY
Since 1961
EVAC
EVAC125HG EVAC150HPS EVAC100MH
25
25
Feam Catalogue 01- 9
Ex Lighting
EVAC Installation and mounting details
EVAC Polar diagrams photometric data
Pole mounting / Assemblig detail with pole (typical)
SEALINGFITTINGS
SEALINGFITTINGS
POLEPOLE
-
8/11/2019 01_FEAM_N
10/94YOUR PARTNER FOR SAFETY
Since 1961
EVAC
EVAC250HG-D EVAC400HPS-D EVAC400MH-D
CODE DESCRIPTION INSTALLATION MATERIAL
10 - Feam Catalogue 01
EVAC Polar diagrams photometric data
EVAC On request accessories
20302.0070 EVAC 100 / 101 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUMININIUM
20302.0071 EVAC 200 / 201 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUMININIUM
20302.0072 EVAC 300 / 301 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUMININIUM
20302.0073 EVAC 500 / 501 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUMININIUM
20302.0025 EVAC 100 / 101 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL
20302.0026 EVAC 200 / 201 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL
20302.0027 EVAC 300 / 301 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL
20302.0028 EVAC 500 / 501 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL
20302.0074 EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL
20302.0075 EVAC 200 / 201 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL
20302.0076 EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL
20302.0077 EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL
20302.0037 EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL
20302.0038 EVAC 200 / 201 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL
20302.0039 EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL
20302.0040 EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL
20302.0078 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 AISI 316LSTAINLESS STEEL
20302.0079 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 AISI 316LSTAINLESS STEEL
20302.0082 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 AISI 316LSTAINLESS STEEL
REMARK:Due to the development of the national and international specications and of the technology, the above technical characteristics showedon this bulletin can be considered as binding on our conrmation only.
Ex Lighting
-
8/11/2019 01_FEAM_N
11/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EVAC-FL
EVAC-FL
LIGHTING FIXTURESFOR FLUORESCENT LAMPS
Ex Lighting
ON REQUEST ACCESSORIES:
Ceiling mounting AISI 316L stainless steel kit complete with stainless steel hardware
Pendant mounting AISI 316L stainless steel kit complete with stainless steel hardware
Pole mounting kit 1 1 1/2 2 dia. complete with stainless steel hardware
Wall/Structure mounting kit complete with stainless steel hardware
Galvanized steel wire protection guard
Threaded cable entry different than standard
Stainless steel wire protection guard
White stove enamelled aluminium reectors
Stainless steel reectors
External painting colour on request
Electronic ballast with voltage supply different than standard
Mechanical characteristics
Body marine grade copper free aluminium (control gear & lamp body)
Globe high-temperature resistant borosylicate glass
Painting external epoxy powders grey RAL-9006 colour
Screws external stainless steel
Gaskets silicon rubberCable entry 3/4 NPT size threaded
Installation swivel bracket AISI 316L stainless steel
Electrical characteristics
Power supply (prc) elettronic ballast 220V/240V - 50/60Hz (p.f.corrected - cos 0,98)
Lampholders porcelain E27 size - plastic 2G10 size
Internal wiring high-temperature resistant silicon rubber insulation cables
Terminals suitable up to 4mm/sq cables
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)Classifcation:Group II - Category 2G 2D
Feam Catalogue 01- 11
LIGHTING FIXTURE / CONTROL GEAR
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex d IIC T6/T2
II 2 D Ex tD A21 T80C / T290C
1Ex d IIC T6 X
DIP A21 TA(80)C
1Ex d IIC T6 X
DIP A21 TA(80)C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 01 ATEX 0054X POCC IT. 05.B02536 No. 07/43-269
RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-1
51330.9-99 ( 60079-10-95)
51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
-
8/11/2019 01_FEAM_N
12/94YOUR PARTNER FOR SAFETY
Since 1961
EVACFL
.
B C
3/4
D
E
A
80 6060
8.5
180200
80
60
16
3
A
.
E
D
B C
2X3/4
A
D
E
B C
200
30
10
2828
192
5
1-1/2
A B
C
EVAC101-15FL 1 x 15W T6 T 80C E-27 1 x 3/4 A
EVAC100-15FL 1 x 15W T6 T 80C E-27 2 x 3/4 B
EVAC201-23FL 1 x 23W T6 T 80C E-27 1 x 3/4 A
EVAC301-218FL 2 x 18W T6 T 80C 2G-10 2 x 3/4 C
EVAC301-318FL 3 x 18W T6 T 80C 2G-10 2 x 3/4 C
EVAC501-236FL 2 x 36W T6 T 80C 2G-10 2 x 3/4 C
EVAC501-336FL 3 x 36W T6 T 80C 2G-10 2 x 3/4 C
EVAC101-15FL 150 270 235 145 280 3,5 1 x 3/4 A
EVAC100-15FL 150 270 235 145 280 3,5 4 x 3/4 B
EVAC201-23FL 175 270 255 170 345 4 1 x 3/4 A
EVAC301-218FL 225 605 590 190 395 12 2 x 3/4 C
EVAC301-318FL 225 605 590 190 395 12 2 x 3/4 C
EVAC501-236FL 225 648 620 255 515 15,5 2 x 3/4 C
EVAC501-336FL 225 648 620 255 515 15,5 2 x 3/4 C
12 - Feam Catalogue 01
Ex Lighting
EVAC-FL Technical data
EVAC-FL Technical features
LIGHTING FIXTURES FOR FLUORESCENT LAMPS - POWER SUPPLY 220V/240V - 50/60Hz
CODE A [mm] B [mm] C [mm] D [mm] E [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
Reference details Reference details
Reference details
CODE LAMPTEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)
LAMPHOLDER
SIZE
CABLE ENTRY
SIZEDETAIL
-
8/11/2019 01_FEAM_N
13/94YOUR PARTNER FOR SAFETY
Since 1961
EVAC-FL
237
180
58283
275
5
4
16
Feam Catalogue 01- 13
EVAC-FL Installation and mounting details
Ceiling mounting
Pendant mounting
Wall/structure mounting
type 1
type 2
type 3
Ex Lighting
-
8/11/2019 01_FEAM_N
14/94YOUR PARTNER FOR SAFETY
Since 1961
EVACFL
25
25
14 - Feam Catalogue 01
EVAC-FL Installation and mounting details
Pole mounting
EVAC-FL On request accessories
REMARK:Due to the development of the national and international specications and of the technology, the above technical characteristicsshowed on this bulletin can be considered as binding on our conrmation only.
20302.0070 EVAC 100 / 101 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM.
20302.0071 EVAC 200 / 201 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM.
20302.0072 EVAC 300 / 301 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM.
20302.0073 EVAC 500 / 501 SIZE STANDARD REFLECTOR WHITE STOVE ENAMELLED ALUM.
20302.0025 EVAC 100 / 101 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL
20302.0026 EVAC 200 / 201 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL
20302.0027 EVAC 300 / 301 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL
20302.0028 EVAC 500 / 501 SIZE STAINLESS STEEL REFLECTOR STAINLESS STEEL
20302.0074 EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL
20302.0075 EVAC 200 / 201 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL
20302.0076 EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL
20302.0077 EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL
20302.0037 EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL
20302.0038 EVAC 200 / 201 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL
20302.0039 EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL
20302.0040 EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL
20302.0078 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 AISI 316LSTAINLESS STEEL
20302.0079 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 AISI 316LSTAINLESS STEEL
20302.0082 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 AISI 316LSTAINLESS STEEL
SEALINGFITTINGS
SEALINGFITTINGS
POLEPOLE
CODE DESCRIPTION INSTALLATION MATERIAL
Ex Lighting
-
8/11/2019 01_FEAM_N
15/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EVP-100
EVP-100
Feam Catalogue 01- 15
PORTABLE LIGHTING FIXTURESFOR INCANDESCENT LAMPS
Ex Lighting
ON REQUEST ACCESSORIES:
External painting colour on request
Mechanical characteristics
Body marine grade copper free aluminium (control gear & lamp body)
Globe high-temperature resistant borosylicate glass
Painting external epoxy powders grey RAL-9006 colour
Screws external stainless steel
Gaskets silicon rubber
Cable entry Nickel plated brass cable gland 1/2 NPT (armoured cable)
Electrical characteristics
Power supply 12 230V AC/DC
lampholders E27 porcelain
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts)Classication: Group II - Category 2G 2D
LIGHTING FIXTURE
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex d IIC T4/T2
II 2 D Ex tD A21 T130C
1Ex d IIC T4 (T5T2) X
DIP A21 TA(130)C
1Ex d IIC T4 (T5T2) X
DIP A21 TA(130)C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 01 ATEX 0054X POCC IT. 05.B02536 No. 07/43-269
RULES OF COMPLIANCEEN 60079-0; EN 60079-1;
EN 61241-1
51330.9-99 ( 60079-10-95)
51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
-
8/11/2019 01_FEAM_N
16/94YOUR PARTNER FOR SAFETY
Since 1961
EVP100
A
B
D
C
A
16 - Feam Catalogue 01
Ex Lighting
EVP-100 Technical data
EVP-100 Technical features
CODE LAMPTEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)
LAMPHOLDER
SIZE
CABLE
ENTRY SIZEDETAIL
CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
LIGHTING FIXTURE FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz
Reference details
REMARK:Due to the development of the national and international specications and of the technology, the above technical characteristicsshowed on this bulletin can be considered as binding on our conrmation only.
EVP-100 395 257 287 150 4,00 CABLE GLAND 1/2 NPT A
EVP-100 100 W T4 T 130C E-27 CABLE GLAND 1/2 NPT A
-
8/11/2019 01_FEAM_N
17/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
AWLAWL
Feam Catalogue 01- 17
Ex Lighting
ON REQUEST ACCESSORIES:
Galvanized steel wire protection guard
Stainless steel wire protection guard
Aircraft Warning Lights and control panel support manufactured in according to customer specication
External painting colour on request
Threaded cable entry different than standard
Electrical characteristicsLampholders porcelain E27 size
Internal wiring high-temperature resistant silicon rubber insulation cables
Terminals suitable up to 4mm/sq cables
Medium intensity ashingobstruction light 1450 / 2000 cd intensity (over than 45mt distance)
Low intensity steadyobstruction light 30 cd intensity (less than 45mt distance)
Construction single awl - twin awl (1 main + 1 spare) in according to ICAO directive
Mechanical characteristics
Body marine grade copper free aluminium
Globe high-temperature resistant borosylicate glass
Fresnel len shock proof acrilyc material suitable for high temperatures
Painting external epoxy powders grey RAL-9006 colour
Screws external stainless steel
Gaskets silicon rubber
Cable entry 3/4 NPTsize threaded
AIRCRAFT WARNING LIGHTSAND A.W.L. CONTROL PANELS
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)Classifcation:Group II - Category 2G 2D
OBSTRUCTION LIGHTING FIXTURE
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex d IIC T6/T 2
II 2 D Ex tD A21 T80C / T290C
1Ex d IIC T6 (T5T2) X
DIP A21 TA(80290)C
1Ex d IIC T6 (T5T2) X
DIP A21 TA(80290)C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 01 ATEX 0054X POCC IT. 05.B02536 No. 07/43-269
RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-1
51330.9-99 ( 60079-10-95)
51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
CONTROL PANEL
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION
II 2 G Ex d IIB+H2 T6...T3
II 2 D Ex tD A21 T85C T150C
II 2 G Ex d IIC T6/T2
II 2 D Ex tD A21 T80C / T290C
1Ex d IIB+H2 T6T3
DIP A21 TA 85C 150C
1Ex d IIC T6 (T5T2) X
DIP A21 TA (80290)C
1Ex d IIB+H2 T6T3
DIP A21 TA 85C 150C
1Ex d IIC T6 (T5T2) X
DIP A21 TA (80290)C
PROTECTION DEGREE ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTEZIONE MECCANICA IP66 IP66 IP66
ICAO IN ACCORDING TO ICAO DIRECTIVE ANNEX 14
RULES OF COMPLIANCE
EN 60079-0; EN 60079-1;
EN 60079-11; EN 61241-0;
EN 61241-1
51330.9-99 ( 60079-10-95)
51330.13-99 ( 60079 -14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
-
8/11/2019 01_FEAM_N
18/94YOUR PARTNER FOR SAFETY
Since 1961
AWL
D
C C
B
A
AB
C
180
200
A B
EVAC201-F 430 415 200 - 4,50 1 x 3/4 A
EVAC200-F 430 415 200 - 4,50 4 x 3/4 A
EVAC201-XF 280 260 176 - 4,50 1 x 3/4 C
EVAC200-XF 280 260 176 - 4,00 4 x 3/4 C
EVAC201-XFR-24V 280 260 176 - 4,00 1 x 3/4 C
EVAC201-F2R 790 415 200 475 9,00 1 x 3/4 B
EVAC201-XF2R 630 260 176 453 8,00 1 x 3/4 D
EVAC301-25R 345 322 197 - 7,00 1 x 3/4 C
EVAC300-25R 345 322 197 - 7,00 4 x 3/4 C
18 - Feam Catalogue 01
Ex Lighting
AWL Technical data
CODE LAMP TYPE
TEMPERATURE
CLASS
(GAS)
TEMPERATURE
CLASS
(DUSTS)
FLASHING
[x/min.]LAMPHOLDER
CABLE
ENTRY
SIZE
DETAIL
AWL Technical features
CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
Reference details
EVAC201-F 100W INCANDESCENT T4 T 130C - E-27 1 x 3/4 A
EVAC200-F 100W INCANDESCENT T4 T 130C - E-27 4 x 3/4 A
EVAC201-XF 6J XENOFLASH T6 T 80C 65 10 E-27 1 x 3/4 C
EVAC200-XF 6J XENOFLASH T6 T 80C 65 10 E-27 4 x 3/4 C
EVAC201-XFR-24V 6J XENOFLASH T6 T 80C 65 10 E-27 1 x 3/4 C
EVAC201-F2R 2 x 100W INCAND. T4 T 130C - E-27 1 x 3/4 B
EVAC201-XF2R 2 x 6J XENOFLASH T6 T 80C 65 10 E-27 1 x 3/4 D
EVAC301-25R 40W INCANDESCENT T4 T 130C - E-27 1 x 3/4 C
EVAC300-25R 40W INCANDESCENT T4 T 130C - E-27 4 x 3/4 C
-
8/11/2019 01_FEAM_N
19/94YOUR PARTNER FOR SAFETY
Since 1961
AWL
B A
180200
C
C
B
A
C
D
C D
FRESNEL XENOFLASH
ROTALLARM MULTI-LED
Feam Catalogue 01- 19
Ex Lighting
Aircraft warning lights models
Reference details
AWL Technical features
-
8/11/2019 01_FEAM_N
20/94YOUR PARTNER FOR SAFETY
Since 1961
AWL
08 09
0201
AUT. MAN.
OFF
ON
OFF
ON
OFF
ON
03
04 05 06
12
07
OFF
ON
OFF
ON
OFF
ON
OFF
ON
13 14 15
>>
10
OFF
ON
18
11
OFF
ON
1916 17
01
OFF
ON AUT. MAN.
0302
0504 06 07
>>
EX d
20 - Feam Catalogue 01
Ex Lighting
AWL Control panels
REMARK:Due to the development of the national and international specications and of the technology, the above technical characteristicsshowed on this bulletin can be considered as binding on our conrmation only.
WEATHERPROOF IP66
BREATHER
VALVETYPE ECD
INSTRUMENTHOUSING WITHPHOTOELECTRIC CELL
BREATHERVALVE
TYPE ECDE
INSTRUMENTHOUSING WITHPHOTOELECTRIC CELL
CODE DESCRIPTION MATERIAL
20302.0075 EVAC 200 / 201 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL20302.0076 EVAC 300 / 301 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL
20302.0038 EVAC 200 / 201 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL
20302.0039 EVAC 300 / 301 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL
20302.0078 STRUCTURE MOUNTING KIT C/W HARDWARE AISI 316LSTAINLESS STEEL
1030.00055 RED FRESNEL LEN 155mm PLASTIC
1030.00186 ORANGE FRESNEL LEN 155mm PLASTIC
1030.00211 GREEN FRESNEL LEN 155mm PLASTIC
1030.00213 WHITE FRESNEL LEN 155mm PLASTIC
EVAC On request accessories
-
8/11/2019 01_FEAM_N
21/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
MIOL-LIOL
MIOL - LIOL
Ex Lighting
Feam Catalogue 01- 21
ON REQUEST ACCESSORIES:
Stainless steel wire protection guard
Aircraft Warning Lights and control panel support manufactured in according to customer specication
External painting colour on request
Threaded cable entry different than standard
Control panel with simultaneous or catenary multilight ashing system
Electrical characteristics
APPLY TO:
Optical characteristics
Mechanical characteristics
MEDIUM INTENSITY AND LOWINTENSITY MULTILED SYSTEMAIRCRAFT WARNING LIGHTS
OBSTRUCTION WARNING LIGHTS
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex d IIC T6/T2
II 2 D Ex tD A21 T80C / T290C
1Ex d IIC T6 (T5T2) X
DIP A21 TA (80290)C
1Ex d IIC T6 (T5T2) X
DIP A21 TA (80290)C
INSTALLATIONZONE 1 / 2 - ZONE 21 / 22
SAFE AREA
ZONE 1 / 2 - ZONE 21 / 22
SAFE AREA
ZONE 1 / 2 - ZONE 21 / 22
SAFE AREA
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 01 ATEX 0054X POCC IT. 05.B02536 No. 07/43-269
RULES OF COMPLIANCEEN 60079-0; EN 60079-1;
EN 61241-1
51330.9-99 ( 60079-10-95) 51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
INTERNATIONAL
REGULATIONS
COMPLIANCY FOR
VISUAL AIDS
ICAO International Standards and Recommended Practices:Aerodromes - Annex 14 - Volume 1 - 4th Edition (November 2004)
Charapter 6 : Medium Intensity Type B Flashing obstacle light MIOL-BCharapter 6 : Low Intensity Type A-B Steady burning obstacle light LIOL-A / LIOL-B
FAA Advisor Circular AC150/5345-43F E.B.#67 - Lamp type MIOL-B / LIOL-A / LIOL-B
LEDs separate groups with individual led protect ion system - LEDtechnology stalilized by constant current generator
Consumption LIOL-B= 4,8W (single and dual) / MIOL-B = 30W (single) - 60W (dual)
Medium intensity (MIOL) ashing light with intensity 2000 cd (+/-25%) ashing 40 ash/minute
Low intensity (LIOL) steady burning with intensity 32 cd (ashing on request)
Realizationsingle group LEDs system with own reector dual groups LEDs system, each group with own reector(1 main + 1 reserve)
FLARE - AIRPORT - STACKS - HIGH BUILDINGS - CHIMNEYS - TOWER CRANE - PIPELINES - BRIDGES - RADIO AND TELEVISION TOWERSTRANSMISSION LINES - WIND TURBINES - RADAR - and so on
Horizontal beam radiation 360 (MIOL / LIOL)
Vertical beam radiation LIOL= between 5 and 10 / MIOL= 3
Efcency > 91% - pfc factor 0,99
Expetancy life long life time - more than 10 years
Body Marine grade copper free aluminium
GlobeHigh-temperature resistant borosylicate glass (zone 1/2 - 21/22 version)Transparent polycarbonate U/V resistant (safe area version)
Painting External epoxy powders grey RAL-9006colour
Screws External stainless steel
Gaskets Silicon rubber
Cable Entry 3/4" NPTsize threaded
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) - Safe areaClassifcation:Group II - Category 2G 2D
-
8/11/2019 01_FEAM_N
22/94
MIOL
LIOL
YOUR PARTNER FOR SAFETY
Since 1961
315
(FIXING)D
ONOT
NON
ENER
GISE
D
TENSIO
NE WHILE
SOTTO
OPENAPRIRE
L
260
768
310
270
275(FIXING)
A MIOL LIOLB
N ONA P
RI RE
S
O
T
T
O
TEN
SIO
NEOP
EN
NOTDO
WH
I
L
E
E
NERG
ISED
150
445
115,5
135,5
151
(FIXING)
(FIXING)
22 - Feam Catalogue 01
MIOL - LIOL Technical data
MIOL - LIOL Technical featuresReference details Reference details
LIOL-A-S > 10 cd x 1 RED FIXED -Ex-d T6 T80C 1 x 3/4" B
IP66 - - 2 x 3/4" D
LIOL-A-D > 10 cd x 2 RED FIXED -Ex-d T6 T80C 1 x 3/4" B
IP66 - - 2 x 3/4" D
LIOL-B-S > 32 cd x 1 RED FIXED -Ex-d T6 T80C 1 x 3/4" B
IP66 - - 2 x 3/4" D
LIOL-B-D > 32 cd x 2 RED FIXED -Ex-d T6 T80C 1 x 3/4" B
IP66 - - 2 x 3/4" D
MIOL-A-S = 20.000 cd x 1WHITE
FLASHING40 IP66 - - 2 x 3/4" C
MIOL-A-D = 20.000 cd x 2WHITE
FLASHING40 IP66 - - 2 x 3/4" C
MIOL-B-S = 2.000 cd x 1RED
FLASHING40
Ex-d T6 T80C 1 x 3/4" A
IP66 - - 2 x 3/4" C
MIOL-B-D = 2.000 cd x 2RED
FLASHING40
Ex-d T6 T80C 1 x 3/4" A
IP66 - - 2 x 3/4" C
MIOL-C-S = 2.000 cd x 1 RED FIXED -Ex-d T6 T80C 1 x 3/4" A
IP66 - - 2 x 3/4" C
MIOL-C-D = 2.000 cd x 2 RED FIXED -Ex-d T6 T80C 1 x 3/4" A
IP66 - - 2 x 3/4" C
LOW INTENSITY OBSTRUCTION WARNING LIGHTS
MEDIUM INTENSITY OBSTRUCTION WARNING LIGHTS
CODELED LAMP
GROUP
VISUAL AIDS
TYPES
FLASHING
[x/min.]EXECUTION
TEMPERATURE
CLASS (GAS)
TEMPERATURE
CLASS (DUSTS)
CABLE
ENTRIESDETAIL
Ex Lighting
-
8/11/2019 01_FEAM_N
23/94YOUR PARTNER FOR SAFETY
Since 1961
MIOL-LIOL
C MIOL LIOLD
660
320
400
191
410
150
200
240
Feam Catalogue 01- 23
Ex Lighting
MIOL - LIOL Technical features
Reference details Reference details
MIOL - LIOL Main rules for aircraft warning lights
MAIN RULES FOR VISUAL AIDSICAO Annex 14 - Aerodromes Vol. 1 - Chapter 6 / 10 (July 2004)
The marking and/or lighting of obstacles is intended to reduce hazards to aircraft by indicating the presence of the obstacles (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.1)
Marking (red-orange/white painting) is used for day time Marking may be ommitted when the obstacle is lighted
A xed obstacle above a horizontal surface should be marked and, if the aerodrome is used at night, lighted.. (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.1.4)
A system of preventive maintenance of visual aids shall be employed to ensure lighting and marking system reliability (ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 10.4.2)
The reliability of installed lighting equipments shold not less than one year(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 10.4.6)
The number and arrangement of Low, Medium or High Intensity Obstacle Lights , at each level to be marked, shall be such that the objectis indicated from every angle in azimuth
Where a light is shielded in any direction by another, additional light shall be provided(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.22)
The number of lights needed for each level depends on the outside diameter of the obstacle The top lights should be placed sufciently below the top, so as to minimize contamination by smoke, powders, and so on..
(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.12)
AWL TYPES (Aircraft Warning Lights)
LIOL-A / BLow Intensity Obstacle Lights on xed objects, Type-A / Type-B, shall be steady burning RED lights
(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.23)
MIOL-A Medium Intensity Obstacle Lights on xed objects, Type-A , shall be ashing WHITE lightsMIOL-B Medium Intensity Obstacle Lights on xed objects, Type-B , shall be ashing RED lightsMIOL-C Medium Intensity Obstacle Lights on xed objects, Type-C , shall be steady burning RED lights(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.30)MIOL-A / MIOL-B Medium Intensity Obstacle Lights Type-A / Type-B, located on an obstacle, shall be ash simultaneously(ICA: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.32)
HIOL-A / B High Intensity Obstacle Lights on xed objects, Type-A / Type-B, shall be ashing WHITE lights(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.33)HIOL-A High Intensity Obstacle Lights Type-A, located on an obstacle, shall be ash simultaneously(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.35)HIOL-B High Intensity Obstacle Lights Type-B, indicating the presence of tower supporting overhead wires, an others.. shall be ash sequentially(ICAO: Aerodromes - Annex 14 - Vol. 1 - Ch. 6.3.36)
-
8/11/2019 01_FEAM_N
24/94YOUR PARTNER FOR SAFETY
Since 1961
MIOL
LIOL
> 45 m
> 150 m
24 - Feam Catalogue 01
MIOL - LIOL Indicative diagram to obstruction light selection
OBSTACLE ELEVATION
LIOL-A
MIOL-B + LIOL-B
LIOL-B
MIOL-C
YES
YES NO
NO
NO YES
YES
VERTICAL
EXTENDED
NO
MIOL - LIOL Polar diagrams photometric data
REMARK:Due to the development of the national and international specications and of the technology, the above technical characteristicsshowed on this bulletin can be considered as binding on our conrmation only.
MIOL - LIOL On request accessories
20302.0074 EVAC 100 / 101 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL
20302.0077 EVAC 500 / 501 SIZE STANDARD PROTECTION GUARD GALVANIZED STEEL
20302.0037 EVAC 100 / 101 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL
20302.0040 EVAC 500 / 501 SIZE STAINLESS STEEL PROTECTION GUARD STAINLESS STEEL
CONTROL PANEL WITH SIMULTANEOUS OR CATENARY MULTILIGHT FLASHING SYSTEM ALUMINIUM / PAINTED STEEL
LIOL 32cd - POLAR MIOL 2000cd - POLARLIOL 32cd - CARTESIAN MIOL 2000cd - CARTESIAN
LEGEND
(1) Painted obstacle in acc. to ICAOdirective
LIOL-A Low intensity obstruction light - TYPE A
LIOL-B Low intensity obstruction light - TYPE B
MIOL-A Medium intensity obstruction light - TYPE A
MIOL-B Medium intensity obstruction light - TYPE B
MIOL-C Medium intensity obstruction light - TYPE C
HIOL-A High intensity obstruction light - TYPE A
HIOL-B High intensity obstruction light - TYPE B
DUAL HIOL-A/B
DAY: HIOL-A+ NIGHT: MIOL-B
DUAL HIOL-A/C
DAY: HIOL-A+ NIGHT: MIOL-C
HIOL-A
DAY: HIOL-ANIGHT: HIOL-A
DUAL MIOL-A/B
DAY: MIOL-A+ NIGHT: MIOL-B
DUAL MIOL-A/C
DAY: MIOL-A+ NIGHT: MIOL-C
MIOL-A
DAY: MIOL-ANIGHT: MIOL-A
STRUCTURE
TYPE
MARKEDSTRUCTURE (1)
MARKEDSTRUCTURE (1)
CODE DESCRIPTION MATERIAL
Ex Lighting
VH Planes VH Planes VH Planes VH Planes
H Angles H Angles
Flux 76.52 Im
Maximum 69.78 cd
Position H=-35.00 V=5.00
Efciency: 100.00%
asymmetric VH
Flux 76.52 Im
Maximum 69.78 cd
Position H=-35.00 V=5.00
Efciency: 100.00%
asymmetric VH
Flux 1864.58 Im
Maximum 4301.23 cd
Position H=80.00 V=-90.00
Efciency: 100.00%
asymmetric VH
Flux 1864.58 Im
Maximum 4301.23 cd
Position H=80.00 V=-90.00
Efciency: 100.00%
asymmetric VH
-
8/11/2019 01_FEAM_N
25/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
SFDESFDE
Feam Catalogue 01- 25
FLOODLIGHTS FOR HALOGEN ANDDISCHARGE LAMPS
Ex Lighting
ON REQUEST ACCESSORIES:
External painting colour on request
Control gear with voltage supply different than standard
Threaded cable entry different than standard
Mechanical characteristics
Body marine grade copper free aluminium
Diffuser tempered front glass
Support adjustable type hot dip galvanized steel
Reector internal polished aluminium
Painting external epoxy powders grey RAL-9006colourScrews external stainless steel
Gaskets silicon rubber
Cable entry 3/4 NPT size threaded
Electrical characteristics
Power supply conventional ballast 230V - 50Hz (p.f.corrected - cos 0,95)
Lampholders porcelain E40 size
Internal wiring high-temperature resistant silicon rubber insulation cables
Terminals suitable up to 4mm/sq cables
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)Classication: Group II - Category 2G 2D
FLOODLIGHT / PROJECTOR
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex d / Ex de IIB T3/T2
II 2 D Ex tD A21 T200C / T229C
1Ex de IIB T6 (T3T2)
DIP A21 TA(200230) C
1Ex de IIB T6 (T3T2)
DIP A21 TA(200230) C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 01 ATEX 0018 POCC IT. 05.B02536 No. 07/43-269
RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-1
51330.9-99 ( 60079-10-95)
51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
-
8/11/2019 01_FEAM_N
26/94YOUR PARTNER FOR SAFETY
Since 1961
SFDE
SFD250HPS SFD400MH SFD500IA
B
110 110
110 110
A F C
D
E
2 x ISOM20 2 x ISOM20
A
SFDE250MH 250 W T4 T 200C E-40 2 x ISO-M20 A
SFDE400MH 400 W T3 T 200C E-40 2 x ISO-M20 A
SFDE150HPNA 150 W T4 T 200C E-40 2 x ISO-M20 A
SFDE250HPNA 250 W T4 T 200C E-40 2 x ISO-M20 A
SFDE400HPNA 400 W T3 T 200C E-40 2 x ISO-M20 A
SFDE500IA 500 W T2 T 229C E-40 2 x ISO-M20 A
SFDE150HPNA 485 425 290 270 504 88 25,00 2 x ISO-M20 A
SFDE250HPNA 485 425 290 270 504 88 25,00 2 x ISO-M20 A
SFDE400HPNA 485 425 290 270 504 88 25,00 2 x ISO-M20 A
SFDE250MH 485 425 290 270 504 88 25,00 2 x ISO-M20 A
SFDE400MH 485 425 290 270 504 88 25,00 2 x ISO-M20 A
SFDE500 IA 485 425 290 270 504 88 21,00 2 x ISO-M20 A
26 - Feam Catalogue 01
Ex Lighting
SFDE Technical data
SFDE Technical features
CODEPOWER
LAMP
TEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)
LAMPHOLDER
SIZE
CABLE ENTRY
SIZEDETAIL
FLOODLIGHTS FOR HALOGEN LAMP - POWER SUPPLY 230V-50Hz
FLOODLIGHTS FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V-50Hz
FLOODLIGHTS FOR METAL HALIDE LAMP - POWER SUPPLY 230V-50Hz
REMARK:Due to the development of the national and international specications and of the technology, the above technical characteristicsshowed on this bulletin can be considered as binding on our conrmation only.
Reference details
CODE A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
-
8/11/2019 01_FEAM_N
27/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
RCDERCDE
Feam Catalogue 01- 27
Ex Lighting
ON REQUEST ACCESSORIES:
External painting colour on request
Control gear with voltage supply different than standard
Threaded cable entry different than standard
Electrical characteristicsPower supply conventional ballast 230V - 50Hz (p.f.corrected - cos 0,95)
Lampholders porcelain E40 size
Internal wiring high-temperature resistant silicon rubber insulation cables
Terminals suitable up to 4mm/sq cables
Mechanical characteristics
Body marine grade copper free aluminiumDiffuser tempered front glass
Support adjustable type hot dip galvanized steel
Reector internal polished aluminium
Painting external epoxy powders grey RAL-9006colour
Screws external stainless steel
Gaskets silicon rubber
Cable entry 3/4 NPTsize threaded
FLOODLIGHTS FOR INCANDESCENTAND DISCHARGE LAMPS
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)Classication: Group II - Category 2G 2D
FLOODLIGHT / PROJECTOR
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex d IIC T4/T3/T2
II 2 D Ex tD A21 T135C/T160C T200C/T230C
1Ex d IIC T4/T3/T X
DIP A21 TA200C,
DIP A21 TA(135, 160, 200, 230)C
1Ex d IIC T4/T3/T2 X
DIP A21 TA(135, 160, 200, 230)C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 03 ATEX 0004 X POCC IT. 05.B02536 No. 07/43-269
RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-1
51330.9-99 ( 60079-10-95)
51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
CONTROL GEAR
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex d IIC T6/T 2
II 2 D Ex tD A21 T80C/T290C
1Ex d IIC T6 (T5T2) X
DIP A21 TA (80290)C
1Ex d IIC T6 (T5T2) X
DIP A21 TA (80290)C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 01 ATEX 0054X POCC IT. 05.B02536 No. 07/43-269
RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-1
51330.9-99 ( 60079-10-95)
51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
-
8/11/2019 01_FEAM_N
28/94YOUR PARTNER FOR SAFETY
Since 1961
RCDE
RECDE500 250HPNA 250 W T4 T 135C E-40 3x3/4 B
RECDE500 400HPNA 400 W T3 T 200C E-40 3x3/4 B
RECDE500 250HG 250 W T3 T 160C E-40 3x3/4 B
RECDE500 400HG 400 W T3 T 200C E-40 3x3/4 B
A B 1x3/41x3/4
CC
220
220
B
B
A
A
D
RCDE250MH RCDE250HG RCDE250HPS
RECDE500 500 W T3 T 200C E-40 1x3/4 A
RECDE500 500 W T2 T 230C E-40 1x3/4 A
RECDE500 250MH 250 W T4 T 135C E-40 3x3/4 B
RECDE500 400MH 400 W T3 T 200C E-40 3x3/4 B
RECDE500 542 378 376 - 21,00 1 x 3/4 A
RECDE500 250HG 542 378 406 700 29,00 3 x 3/4 B
RECDE500 250HPNA 542 378 406 700 29,50 3 x 3/4 B
RECDE500 400HG 542 378 406 700 31,00 3 x 3/4 B
RECDE500 400HPNA 542 378 406 700 31,50 3 x 3/4 B
RECDE500 250MH 542 378 406 700 26,50 3 x 3/4 B
RECDE500 400MH 542 378 406 700 31,50 3 x 3/4 B
Ex Lighting
RCDE Technical data
RCDE Technical features
FLOODLIGHTS FOR METAL HALIDE LAMP - POWER SUPPLY 230V-50Hz
FLOODLIGHTS FOR HIGH PRESSURE SODIUM LAMP - POWER SUPPLY 230V-50Hz
FLOODLIGHTS FOR HIGH PRESSURE MERCURY VAPOUR LAMP - POWER SUPPLY 230V-50Hz
FLOODLIGHTS FOR BLENDED LIGHT LAMP - POWER SUPPLY 230V-50Hz
FLOODLIGHTS FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz
CODE LAMPTEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)
LAMPHOLDER
SIZE
CABLE ENTRY
SIZEDETAIL
CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
REMARK: Due to the development of the national and international specications and of the technology, the above technicalcharacteristics showed on this bulletin can be considered as binding on our conrmation only.
28 - Feam Catalogue 01
2x3/4with PLG2
-
8/11/2019 01_FEAM_N
29/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EVO-EVT-TLF
EVO - EVT - TLF
Feam Catalogue 01- 29
Ex Lighting
ON REQUEST ACCESSORIES:
External painting colour on request
Threaded cable entry different than standard
Electrical characteristicsPower supply standard voltage 230V - 50Hz
Lampholders porcelain E27 sizeInternal wiring high-temperature resistant silicon rubber insulation cables
Mechanical characteristics
Body marine grade copper free aluminium
Diffuser borosilicate frontal glass (EVT)
Diffuser tempered frontal glass (EVO - TLF)
Painting external epoxy powders grey RAL-9006colour
Screws external stainless steel
Gaskets silicon rubber
Cable entry 3/4 NPTsize threaded
Protection guard galvanized wire steel (EVT ONLY)
LIGHTING FIXTURESFOR INCANDESCENT LAMPS
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)Classication: Group II - Category 2G 2D
PORTHOLE LIGHTING FIXTURE (EVO)
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION II 2 G Ex d IIC T3, II 2 D Ex tD A21 T200C 1Ex d IIC T3 X, DIP A21 TA200C 1Ex d IIC T3 X, DIP A21 TA200C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 01 ATEX 0039 X POCC IT. 05.B02536 No. 07/43-269
RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 51330.9-99 ( 60079-10-95) 51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99 61241-1-1-2002
LIGHTING FIXTURE (EVT)
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTION II 2 G Ex d IIC T4, II 2 D Ex tD A21 T135C 1Ex d IIC T4, DIP A21 TA135C 1Ex d IIC T4, DIP A21 TA135C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. INERIS 01 ATEX 0040 POCC IT. 05.B02536 No. 07/43-269
RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 51330.9-99 ( 60079-10-95) 51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99 61241-1-1-2002
LIGHTING FIXTURE (TLF)
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex d / Ex de IIB T3
II 2 D Ex tD A21 T200C
1Ex d IIB T3, 2Ex de IIB T3DIP A21 TA 200C
1Ex d IIB T3, 2Ex de IIB T3DIP A21 TA 200C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP65 IP65 IP65
CERTIFICATE REF. INERIS 01 ATEX 0026 POCC IT. 05.B02536 No. 07/43-269
RULES OF COMPLIANCE EN 60079-0; EN 60079-1; EN 61241-0; EN 61242-1 51330.9-99 ( 60079-10-95) 51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99 61241-1-1-2002
-
8/11/2019 01_FEAM_N
30/94YOUR PARTNER FOR SAFETY
Since 1961
EVO
EVT
TLF
1 x 3/4
C
A
B
2 x 3/4
B C
A
C
A
B
2 x 3/4
A
C
B
EVO100 140 185 162 2,00 1 x 3/4 A
EVT100 233 180 155 4,00 2 x 3/4 B
TLF100 309 127 165 3,00 2 x 3/4 C
EVO100 100 W T3 T 200C E-27 1x3/4 A
EVT100 100 W T4 T135C E-27 2x3/4 B
TLF100 100 W T3 T 200C E-27 2x3/4 C
30 - Feam Catalogue 01
Ex Lighting
EVO EVT - TLF Technical data
EVO EVT - TLF Technical features
REMARK:Due to the development of the national and international specications and of the technology, the above technical characteristicsshowed on this bulletin can be considered as binding on our conrmation only.
CODE LAMPTEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)
LAMPHOLDER
SIZE
CABLE ENTRY
SIZEDETAIL
LIGHTING FIXTURE FOR INCANDESCENT LAMP - POWER SUPPLY 230V-50Hz
CODE A [mm] B [mm] C [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
Reference details
-
8/11/2019 01_FEAM_N
31/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EXLEXL
Feam Catalogue 01- 31
Ex Lighting
ON REQUEST ACCESSORIES:
External painting colour on request
Electronic ballast with voltage supply different than standard
Threaded cable entry different than standard
Self-adhesive green label with EXIT sign (language on request)
Mechanical characteristics
Body marine grade copper free aluminium
Diffuser high-temperature resistant borosylicate glass
Painting external epoxy powders grey RAL-9006 colour
Screws external stainless steel
Reectors white stove enamelled sheet steel
Cable entry 3/4 NPT size threaded c/w cable gland
Electrical characteristics
Power supply elettronic ballast 220V/240V - 50/60Hz (p.f.corrected - cos 0,98)
Lampholders bi-pin G5 cap (uorescent lamp only)
Internal wiring high-temperature resistant silicon rubber insulation cables
Terminals suitable up to 4mm/sq cables
Emergency unit emergency unit with inverter charger and Ni-Cd battery pack
see technical features for more details
LIGHTING FIXTURES FOR HIGHEFFICENCY LED LAMPSAND FLUORESCENT TUBE LAMPS
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)Classication: Group II - Category 2G 2D
EXL08E / EXL08ESA - 8W uorescent lamp: emergency light intensity is 40% of light intensity with networking power supply EXL08LE - with high brightness LEDs (350mA -4.8 W): emergency light intensity is 100% of light intensity with networking power supply
Functional characteristics
Remarks
LIGHTING FIXTURE
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex d IIB T6
II 2 D Ex tD A21 T85C
1Ex d IIB T6, 1Exd [ia/ib] IIB T6,
DIP A21 TA 85C
1Ex d IIB T6, 1Exd [ia/ib] IIB T6,
DIP A21 TA 85C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. IMQ 09 ATEX 020 POCC IT. 05.B02537 No. 07/43-269
RULES OF COMPLIANCEEN 60079-0; EN 60079-1; EN 61241-0;
EN 61242-1
51330.9-99 ( 660079-10-95)
51330.13-99 ( 660079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
EXL08ESA (Always ON - Maintained): 8W uorescent lamp and electronic ballast 230V AC and emergency unit 3.6 V - 2Ah for an autonomy of 2 hours3.6 V - 4Ah for an autonomy 3 hours
EXL08E (Emergency only - Maintained): 8W uorescent lamp and emergency unit 3.6 V - 2Ah with autonomy 3 hours EXL08L (Network only - Not Maintained): with high brightness LEDs (350mA - 4,8 W) Supply from 120V to 240V AC / DC EXL08LE (Emergency only - Maintained): with high brightness LEDs (350mA - 4,8 W) 220/240V AC and emergency unit 6V - 2Ah for an
autonomy of 3 hours complete with charge status monitor LED system (RED: battery under charging GREEN: battery loaded)
-
8/11/2019 01_FEAM_N
32/94YOUR PARTNER FOR SAFETY
Since 1961
EXL
EXL-08 EXL-08L EXL2-08L
E
3/4"
C A
D
B
A
EXL08 380 170 125 370 125 8,00 1 x 3/4 A
EXL08E-3 380 170 125 370 125 8,00 1 x 3/4 A
EXL08ESA-3 380 170 125 370 125 8,00 1 x 3/4 A
EXL08L 380 170 125 370 125 8,00 1 x 3/4 A
EXL08LE 380 170 125 370 125 8,00 1 x 3/4 A
EXL208L 380 170 125 370 125 8,00 1 x 3/4 A
EXL08 220 240V AC 8 W - T6 T 85C - -
EXL08E-3 220 240V AC 8 W - T6 T 85C 3,6V - 4A/h 3h
EXL08ESA-3 220 240V AC 8 W - T6 T 85C 3,6V - 4A/h 3h
EXL08L 120 240V AC/DC 4,8 W 350 T6 T 85C - -
EXL08LE 220 240V AC 4,8 W 350 T6 T 85C 3,6V - 2A/h 3h
EXL208L 120 240V AC/DC 9,16 W 350 T6 T 85C - -
32 - Feam Catalogue 01
EXL Technical data
EXL Technical features
CODE POWER SUPPLY LAMP mA (LED)TEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)
EMERGENCY
UNITAUTONOMY
LIGHTING FIXTURES FOR FLUORESCENT TUBE LAMPS
LIGHTING FIXTURES FOR HIGH EFFICENCY LED LAMPS
CODE A [mm] B [mm] C [mm] D [mm] E [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
Reference details
REMARK: Due to the development of the national and international specications and of the technology, the above technicalcharacteristics showed on this bulletin can be considered as binding on our conrmation only.
EXL On request accessories
CODE DESCRIPTION MATERIAL
2070.00088 SELF-ADHESIVE GREEN EXIT LABEL POLYESTER
Ex Lighting
-
8/11/2019 01_FEAM_N
33/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EVGEVG
Feam Catalogue 01- 33
ON REQUEST ACCESSORIES:
Pole mounting kit complete with stainless steel hardware
Ceiling mounting kit complete with stainless steel hardware
Pendant mounting kit complete with stainless steel hardware
Wall/Structure mounting kit complete with stainless steel hardware
Electronic ballast with voltage supply different than standard
Electrical characteristicsPower supply elettronic ballast 220V/240V - 50/60Hz (p.f.corrected - cos 0,98)
Lampholders bi-pin G13 cap
Internal wiring high-temperature resistant silicon rubber insulation cables
Terminals suitable up to 6mm/sq cables
Safety feature end of life switching-off system in according to EN 60079-7 rules
Emergency unit emergency unit composed of inverter charger and Ni-Cd battery pack 7A/h 6V autonomy up to 180 min.
Advantages see table advantage features
Mechanical characteristicsBody glass bre reinforced polyester resin
diffuser U/V resistant polycarbonate - hinged to body
safety closing operated by triangular key
gaskets EPDM rubber suitable for high temperatures and resistant to enviroments conditions
internal reector white polyester highly refractor diffuser
cable entry ISO-Metric thread c/w plastic cable glands and stopping plug
Ex Lighting
LIGHTING FIXTURES FORFLUORESCENT TUBE LAMPS
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)Classication: Group II - Category 2G 2D
18W LIGHTING FIXTURE 36W LIGHTING FIXTURE
ATEX 94/9/EC GOST-R (RTR / RTN) ATEX 94/9/EC
EXECUTIONII 2 G Ex edq IIC T4
II 2 D Ex tD A21 T 80C
2Ex edq IIC T4 (T6)
DIP A21 TA80C
II 2 G Ex edq IIC T4
II 2 D Ex tD A21 T 80C
AMBIENT TEMPERATURE -20C +60C -20C +60C -20C +55C
PROTECTION DEGREE IP66 IP66 IP66/64
CERTIFICATE REF. PTB 97 ATEX 2223 POCC DE. 05.B01788 PTB 07 ATEX 2040
RULES OF COMPLIANCEEN 60079-0; EN 60079-1;
EN 61241-0; EN 61242-1
51330.9-99 ( 660079-10-95)
51330.13-99 ( 660079-14-96)
61241-3-99
EN 60079-0; EN 60079-1;
EN 61241-0; EN 61242-1
58W LIGHTING FIXTURE LIGHTING FIXTURES WITHEMERGENCY UNIT ONLY
ATEX 94/9/EC GOST-R (RTR / RTN) ATEX 94/9/EC
EXECUTIONII 2 G Ex edq IIC T4
II 2 D Ex tD A21 T 90C
2Ex edq IIC T4 (T6)
DIP A21 TA90CII 2 GD Ex edq IIC T4 T80C
AMBIENT TEMPERATURE -20C +60C -20C +60C -20C +55C
PROTECTION DEGREE IP66 IP66 IP66/64
CERTIFICATE REF. PTB 97 ATEX 2225 POCC DE. 05.B01788 PTB 05 ATEX 2066
RULES OF COMPLIANCEEN 60079-0; EN 60079-1;
EN 61241-0; EN 61242-1
51330.9-99 ( 660079-10-95)
51330.13-99 ( 660079-14-96)
61241-3-99
EN 60079-0; EN 60079-1;
EN 61241-0; EN 61242-1
-
8/11/2019 01_FEAM_N
34/94
EVG
YOUR PARTNER FOR SAFETY
Since 1961
SH-21EVG 786 160 214 600 10,00 3 x ISO-M25 A
SH-41EVG 1355 150 226 716 13,00 3 x ISO-M25 A
SH-61EVG 1696 160 214 800 16,00 3 x ISO-M25 A
SH-22EVG 786 160 214 600 10,50 3 x ISO-M25 A
SH-42EVG 1355 150 226 716 13,50 3 x ISO-M25 A
SH-62EVG 1696 160 214 800 16,50 3 x ISO-M25 A
SH-22EVG-E 913 160 221 600 9,40 2 x ISO-M25 BSH-42EVG-E 1523 160 221 800 12,80 2 x ISO-M25 B
A
D
C
B
A
D
C
B
SH-21EVG 1 x 18W T4 (Ta = -20C / +60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 - - A
SH-41EVG 1 x 36W T4 (Ta = -20C / +60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 - - A
SH-61EVG 1 x 58W T4 (Ta = -20C / +60C) T 90C (Ta = -20C / +60C) G13 3 x ISO-M25 - - A
SH-22EVG 2 x 18W T4 (Ta = -20C / +60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 - - A
SH-42EVG 2 x 36W T4 (Ta = -20C / +60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 - - A
SH-62EVG 2 x 58W T4 (Ta = -20C / +60C) T 90C (Ta = -20C / +60C) G13 3 x ISO-M25 - - A
SH-22EVG-E 2 x 18W T4 (Ta = -20C / +60C) T 80C (Ta = -20C / +60C) G13 2 x ISO-M25 6 V - 7 A/h 3h B
SH-42EVG-E 2 x 36W T4 (Ta = -20C / +60C) T 80C (Ta = -20C / +60C) G13 2 x ISO-M25 6 V - 7 A/h 3h B
A
B
34 - Feam Catalogue 01
Ex Lighting
EVG Technical data
EVG Technical features
CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
Reference details
FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50/60Hz
EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V-50/60Hz
CODE LAMPTEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)LAMPHOLDER CABLE ENTRY
EMERGENCY
UNITAUTONOMY DETAIL
-
8/11/2019 01_FEAM_N
35/94YOUR PARTNER FOR SAFETY
Since 1961
EVG
50
45
100
100
SH-21EVG SH-22EVG SH-41EVG
Feam Catalogue 01- 35
Ex Lighting
EVG Installation and mounting details
EVG Polar diagrams photometric data
Wall/structure mountingPole mounting
Assemblig detail with pole (typical)
type 3 type 4
type 1 type 2
Ceiling mounting Pendant mounting
-
8/11/2019 01_FEAM_N
36/94YOUR PARTNER FOR SAFETY
Since 1961
EVG
SH-42EVG SH-61EVG SH-62EVG
36 - Feam Catalogue 01
Ex Lighting
EVG Polar diagrams photometric data
REMARK:Due to the development of the national and international specications and of the technology, the above technical characteristicsshowed on this bulletin can be considered as binding on our conrmation only.
EVG with emergency unit
EVG On request accessories
CODE DESCRIPTION INSTALLATION MATERIAL
20301.0162 POLE MOUNTING KIT (SIZE 2 DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL
20301.0163 POLE MOUNTING KIT (SIZE 1 1/2 DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL
20301.0165 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 STAINLESS STEEL
20302.0121 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 GALVANIZED STEEL
20302.0128 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL
LIGHTING FIXTURES AND EMERGENCY UNIT ELECTRICAL DESIGN AND SPECIAL FEATURES
Microprocessor (PLC) END-OF LIFE switching-off system at the end of life a uorescent tube lamp is safely switched off
(according to iec eN-60079-7 stds)
Multi-function led Multi-function led indcator with coded indication of the functions, status and potential failures of the
electronic device and of the batteries
Monitoring Special signal whenever there is a e.o.l. situation (led red ashing )
Automatic weekly functions test
Automatic annual 2/3 times operating period test
Function and operating period test can be done manually also
Maintenance Quick replacement of battery set even in explosive atmosphere presence
Electrical disconnection whenever the batteries box is opened
24h max recharging time (in according to EN-60598-2-22)
Safety Highest degree of safety in case of lamp failure during the emergency light operation
In case of lamp failure during emergency operation the second tube lamp will automatically take over the
emergency operation (two lamps version only)
-
8/11/2019 01_FEAM_N
37/94
-
8/11/2019 01_FEAM_N
38/94YOUR PARTNER FOR SAFETY
Since 1961
e191
e192
e191
e192
e19121 1 x 18W T4 (Ta = -20C 40/50/60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 A
e19122 2 x 18W T4 (Ta = -20C 40/50/60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 A
e19141 1 x 36W T4 (Ta = -20C 40/50/60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 A
e19142 2 x 36W T4 (Ta = -20C 40/50/60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 A
e19161 1 x 58W T4 (Ta = -20C 40/50/60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 A
e19162 2 x 58W T4 (Ta = -20C 40/50/60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 A
e19223 3 x 18W T4 (Ta = -20C 40/50/60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 A
e19224 4 x 18W T4 (Ta = -20C 40/50/60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 A
e19243 3 x 36W T4 (Ta = -20C 40/50/60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 A
e19244 4 x 36W T4 (Ta = -20C 40/50/60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 A
e19263 3 x 58W T4 (Ta = -20C 40/50/60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 A
e19264 4 x 58W T4 (Ta = -20C 40/50/60C) T 80C (Ta = -20C / +60C) G13 3 x ISO-M25 A
e19121 720 82 368 600 404 10,00 3 x ISO-M25 A
e19122 720 82 368 600 404 10,00 3 x ISO-M25 A
e19141 1330 82 368 1200 404 15,50 3 x ISO-M25 A
e19142 1330 82 368 1200 404 15,50 3 x ISO-M25 A
e19161 1630 82 368 1400 404 18,00 3 x ISO-M25 A
e19162 1630 82 368 1400 404 18,00 3 x ISO-M25 A
e19223 720 82 500 600 536 18,50 3 x ISO-M25 A
e19224 720 82 500 600 536 18,50 3 x ISO-M25 A
e19243 1330 82 500 1200 536 25,50 3 x ISO-M25 A
e19244 1330 82 500 1200 536 25,50 3 x ISO-M25 A
e19263 1630 82 500 1400 536 28,50 3 x ISO-M25 A
e19264 1630 82 500 1400 536 28,50 3 x ISO-M25 A
B
E
C
D
A
9
A
38 - Feam Catalogue 01
Ex Lighting
e191 - e192 Technical data
e191 - e192 Lighting xture technical features
CODE LAMPTEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)LAMPHOLDER CABLE ENTRY DETAIL
FLUORESCENT LIGHTING FIXTURES - POWER SUPPLY 220-240V-50/60Hz - DC
Lighting xture Reference details
CODE A [mm] B [mm] C [mm] D [mm] E [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
-
8/11/2019 01_FEAM_N
39/94YOUR PARTNER FOR SAFETY
Since 1961
e191-e192
EB182-18 e19121 388 740 786 93 300 434 82 9
e19122 388 740 786 93 300 434 82 9
EB182-36 e19141 388 1350 1396 98 400 434 82 9
e19142 388 1350 1396 98 400 434 82 9
EB182-58 e19161 388 1650 1696 48 400 434 82 9
e19162 388 1650 1696 48 400 434 82 9
EB192-18 e19223 520 740 786 93 300 566 82 9
e19224 520 740 786 93 300 566 82 9
EB192-36 e19243 520 1350 1396 96 400 566 82 9
e19244 520 1350 1396 96 400 566 82 9
EB192-58 e19263 520 1650 1696 48 400 566 82 9
e19264 520 1650 1696 48 400 566 82 9
e191-42 e192-43 e192-44
BA
C
E E E
G
DD
H
F
Feam Catalogue 01- 39
Ex Lighting
e191 - e192 Recessed frame technical features
CODE LUMINARIE TYPE A [mm] B [mm] C [mm] D [mm] E [mm] F [mm] G [mm] H [mm]
Recessed frame Reference details
e191 - e192 Polar diagrams photometric data
-
8/11/2019 01_FEAM_N
40/94YOUR PARTNER FOR SAFETY
Since 1961
e191
e192
e191-22 e191-23 e191-64
40 - Feam Catalogue 01
e191 - e192 Polar diagrams photometric data
e191 - e192 On request accessories
CODE DESCRIPTION MATERIAL
EB182-18 RECESSED FRAME FOR LIGHTING FIXTURE 1x18W AND 2x18W PAINTED SHEET STEEL
EB182-36 RECESSED FRAME FOR LIGHTING FIXTURE 1x36W AND 2x36W PAINTED SHEET STEEL
EB182-58 RECESSED FRAME FOR LIGHTING FIXTURE 1x58W AND 2x58W PAINTED SHEET STEEL
EB192-18 RECESSED FRAME FOR LIGHTING FIXTURE 3x18W AND 4x18W PAINTED SHEET STEEL
EB192-36 RECESSED FRAME FOR LIGHTING FIXTURE 3x36W AND 4x36W PAINTED SHEET STEEL
EB192-58 RECESSED FRAME FOR LIGHTING FIXTURE 3x58W AND 4x58W PAINTED SHEET STEEL
REMARK:Due to the development of the national and international specications and of the technology, the above technical characteristics showedon this bulletin can be considered as binding on our conrmation only.
Ex Lighting
-
8/11/2019 01_FEAM_N
41/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
AVFAVF
Feam Catalogue 01- 41
Ex Lighting
ON REQUEST ACCESSORIES:
Pole mounting kit complete with stainless steel hardware
Ceiling mounting kit complete with stainless steel hardware
Pendant mounting kit complete with stainless steel hardware
Wall/Structure mounting kit complete with stainless steel hardware
Electronic ballast with voltage supply different than standard
AUTOTEST electronic system for emergency unit
Mechanical characteristics
Body galss bre reinforced polyester resin self-extinguishing acc. to UL94Diffuser U/V resistant polycarbonate - hinged to body
Safety closing operated by hexagonal key
Gaskets EPDM 60 rubber suitable for high temperatures and resistant to enviroments conditions
Internal reector white stove enamelled sheet aluminum
Cable entry ISO-Metric complete with cable glands and plug
Electrical characteristicsPower supply elettronic ballast 220V/240V 50/60Hz (p.f. corrected - cos 0,98)
Lampholders bi-pin G13 cap
Internal wiring high-temperature resistant silicon rubber insulation cables
Terminals suitable up to 6mm/sq cables
Safety feature EEx de safety switch
INCREASED SAFETY LIGHTINGFIXTURES FOR BI-PINFLUORESCENT LAMPS
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)Classication: Group II - Category 2G 2D
LIGHTING FIXTURE
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex ed IIC T5
II 2 D Ex tD A21 T70C
2Ex ed IIC T5
DIP A21 TA 70C
2Ex ed IIC T5
DIP A21 TA 70C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. KEMA 01 ATEX 2069 POCC IT. 05.B02536 No. 07/43-269
RULES OF COMPLIANCEEN 60079-0; EN 60079-1;
EN 60079-7; EN 61241-1
51330.9-99 ( 60079-10-95)
51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
EMERGENCY UNIT
ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K
EXECUTIONII 2 G Ex ed IIC T6
II 2 D Ex tD A21 T85C
1Ex ed IIB T6
DIP A21 TA 85C
1Ex ed IIB T6
DIP A21 TA 85C
INSTALLATION ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP66 IP66 IP66
CERTIFICATE REF. IMQ 08 ATEX 026X POCC IT. 05.B02537 No. 07/43-269
RULES OF COMPLIANCEEN 60070-0; EN 60079-7;
EN 61241-0; EN 61241-1;
51330.9-99 ( 60079-10-95)
51330.13-99 ( 60079-14-96)
61241-3-99
51330.0 / 1 / 8 / 14-99
61241-1-1-2002
-
8/11/2019 01_FEAM_N
42/94YOUR PARTNER FOR SAFETY
Since 1961
AVF
AVF 118 1 x 18W T5 T 70C G13 3 x M20 x 1,5 - - A
AVF 136 1 x 36W T5 T 70C G13 3 x M20 x 1,5 - - A
AVF 218 2 x 18W T5 T 70C G13 3 x M20 x 1,5 - - A
AVF 236 2 x 36W T5 T 70C G13 3 x M20 x 1,5 - - A
AVF 118-E 1 x 18W T5 T 70C G13 2 x M20 x 1,5 4.8 V - 4Ah 3h B
AVF 136-E 1 x 36W T5 T 70C G13 2 x M20 x 1,5 4.8 V - 4Ah 3h B
AVF 218-E 2 x 18W T5 T 70C G13 2 x M20 x 1,5 4.8 V - 4Ah 3h B
AVF 236-E 2 x 36W T5 T 70C G13 2 x M20 x 1,5 4.8 V - 4Ah 3h B
D
B
C
8MA 8MA
A
8MA
D
B
C
8MA 8MA
A
8MA
AVF 118 730 215 160 400 6,00 3 x M20 x 1,5 A
AVF 136 1340 215 160 450 6,50 3 x M20 x 1,5 A
AVF 218 730 215 160 400 7,00 3 x M20 x 1,5 A
AVF 236 1340 215 160 450 7,50 3 x M20 x 1,5 A
AVF 118-E 925 215 280 400 11,00 2 x M20 x 1,5 B
AVF 136-E 1535 215 280 450 11,50 2 x M20 x 1,5 B
AVF 218-E 925 215 280 400 12,00 2 x M20 x 1,5 B
AVF 236-E 1535 215 280 450 12,50 2 x M20 x 1,5 B
A
B
42 - Feam Catalogue 01
FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V 50/60Hz
EMERGENCY FLUORESCENT LIGHTING FIXTURES FOR SINGLE AND TWIN LAMPS - POWER SUPPLY 230V 50/60Hz
Ex Lighting
AVF Technical data
CODE LAMPTEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)LAMPHOLDER
CABLE
ENTRY
EMERGENCY
UNITAUTONOMY DETAIL
AVF Technical featuresCODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
Reference details
-
8/11/2019 01_FEAM_N
43/94YOUR PARTNER FOR SAFETY
Since 1961
AVF
50
45
100
100
AVF218 AVF136 AVF236
Feam Catalogue 01- 43
Ex Lighting
AVF Installation and mounting details
AVF Polar diagrams photometric data
Wall/structure mountingPole mounting
Assemblig detail with pole (typical)
type 3 type 4
type 1 type 2
Ceiling mounting Pendant mounting
-
8/11/2019 01_FEAM_N
44/94YOUR PARTNER FOR SAFETY
Since 1961
AVF
ON ON ON ON ON ON ON ON ON
ON ON ON ON ON ON ON ON ON
OFF OFF OFF OFF OFF OFF OFF OFF OFF
ON ON ON OFF ON ON ON OFF ON
ON OFF ON OFF ON OFF ON OFF ON
ON ON OFF ON ON OFF ON ON OFF
ON OFF ON OFF ON OFF ON OFF ON
ON OFF ON OFF ON OFF ON OFF ON
ON ON ON ON ON ON ON ON ON
44 - Feam Catalogue 01
Ex Lighting
AVF with emergency unit (design and special features)
CODE DESCRIPTION INSTALLATION MATERIAL
REMARK:Due to the development of the national and international specications and of the technology, the above technical characteristicsshowed on this bulletin can be considered as binding on our conrmation only.
AVF On request accessories
Multicolor LED indicator in standard working (continuous led light)
Multicolor LED indicator during test opetarion (intermittent led light)
Multicolor LED indicator during batteries recharging phase
GENERALITY:
The controller unit system permits to manage in AUTOTEST the verify of emergency unit working
This system allows the emergency working of every uorescent tube lamps (NON maintened working)
The check and the control system has been realized by proper microprocessor which perform the following tests :- continuous test on the battery charger working, on the operation of the battery, and on presence of voltage supply
- duration test in emergency working (every 3 months) with check of battery charge
- test of emergency working (weekly) with check of right lamp operation
Every information concerning the checks can be managed singly or tranmitted by remote control system in order to manage complete
illumination system test in centralized way.
Regular operation
Failed battery performance check
Lack of main power supply
Lack of battery
Performing lamp test
Performing battery pack test
Failed lamp test
24 hours
After 24 hours
20301.0162 POLE MOUNTING KIT (SIZE 2 DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL
20301.0163 POLE MOUNTING KIT (SIZE 1 1/2 DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL
20301.0165 PENDANT MOUNTING KIT C/W HARDARE AND EYE-BOLTS TYPE 2 STAINLESS STEEL
20302.0121 CEILING MOUNTING KIT C/W HARDWARE TYPE 1 GALVANIZED STEEL
20302.0128 WALL/STRUCTURE MOUNTING KIT C/W HARDWARE TYPE 3 GALVANIZED STEEL
AUTOTEST ELECTRONIC SYSTEM - -
-
8/11/2019 01_FEAM_N
45/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
SFDQL
SFDQL
Feam Catalogue 01- 45
Ex Lighting
ON REQUEST ACCESSORIES:
Power supply 90 120V AC/DC (55/85W only)
Mechanical characteristics
Body marine grade copper free aluminum
Diffuser tempered front glass
Support steel bracket with rotation-proof system
Reector anodized and polished 99,85 pure aluminum internal opticPainting thermoset ting polyester powder resistant to atmospheric agents and corrosion grey RAL 9006 colour
Screws stainless steel
Gaskets pure silicon heat resistance
Cable entry ISO-Metric complete with nikel plated brass cable gland M20
Electrical characteristics
Power supply 180 230V DC / 180 277V AC x 165W - 55W - 85W
Lamp long life induction lamp (60.000 hours)
Terminals suitable up to 4mm/sq cables
FLOODLIGHT PROJECTORSFOR INDUCTION LAMPS
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)Classication: Group II - Category 2G 2D
FLOODLIGHT
ATEX 94/9/EC
EXECUTIONII 2G Ex eq II T3
II 2D Ex tD A21 T 200C
AMBIENT TEMPERATURE-40C +40C
-40C +60C
PROTECTION DEGREE IP66
CERTIFICATE REF. IMQ 09 ATEX 014X
RULES OF COMPLIANCEEN 60079-0; EN 60079-5; EN 60079-7;
EN 61241-0; EN 61241-1
-
8/11/2019 01_FEAM_N
46/94YOUR PARTNER FOR SAFETY
Since 1961
SFDQL
SFDQL-55JB 430 460 545 260 8,50 2 x ISOM20 A
SFDQL-85JB 430 460 545 260 8,70 2 x ISOM20 A
SFDQL-165JB 430 460 545 260 9,50 2 x ISOM20 A
SFDQL-55 430 460 545 180 8,00 1 x PCE M20 B
SFDQL-85 430 460 545 180 8,20 1 x PCE M20 B
SFDQL-165 430 460 545 180 9,00 1 x PCE M20 B
SFDQL-55JB 55W T3 (Ta = -40C / +60C) T 200C 2 x ISO M20 A
SFDQL-85JB 85W T3 (Ta = -40C / +60C) T 200C 2 x ISO M20 A
SFDQL-55 55W T3 (Ta = -40C / +60C) T 200C 1 x PCE M20 B
SFDQL-85 85W T3 (Ta = -40C / +60C) T 200C 1 x PCE M20 B
SFDQL-165JB 165W T3 (Ta = -40C / +40C) T 200C 2 x ISO M20 A
SFDQL-165 165W T3 (Ta = -40C / +40C) T 200C 1 x PCE M20 B
INDUCTION LAMP
www.feam-ex.com
SFDQL0722
165W
85W
55W
180230V DC
180277V AC
90120V AC/DC
II 2G Ex eq II T3
IMQ 08 ATEX 014X
II 2D Ex tD A21 IP 66 T200 C
55W-85W
Ta -40C / +60C
165W
Ta -40C / +40C
120
A D
155 155
2 X ISO M20
B
C
A
46 - Feam Catalogue 01
Ex Lighting
SFDQL Technical data
SFDQL Technical features
CODE LAMPTEMPERATURE CLASS
(GAS)
TEMPERATURE CLASS
(DUSTS)CABLE ENTRY SIZE DETAIL
FLOODLIGHT FOR INDUCTION LAMP - POWER SUPPLY 220V/240V 50/60Hz - 220V/240V DC - 120V AC/DC
FLOODLIGHT FOR INDUCTION LAMP - POWER SUPPLY 220V/240V 50/60Hz - 220V/240V DC
CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
Reference details
-
8/11/2019 01_FEAM_N
47/94YOUR PARTNER FOR SAFETY
Since 1961
SFDQL
SFDQL55 SFDQL85 SFDQL165
SFDQLINDUCTION LAMP
www.feam-ex.com
0722
165W
85W
55W
180230V DC
180277V AC
90120V AC/DC
II 2G Ex eq II T3
IMQ 08 ATEX 014X
II 2D Ex tD A21 IP 66 T200 C
55W-85W
Ta -40C / +60 C
165W
Ta -40C / +40 C
120
A D
155 155
1 X PCE M20
B
C
B
Ex Lighting
SFDQL Technical features
SFDQL Polar diagrams photometric data
Reference details
Feam Catalogue 01- 47
-
8/11/2019 01_FEAM_N
48/94YOUR PARTNER FOR SAFETY
Since 1961
SFDQL
20303.0099 20303.0100
SFDQL On request accessories
Ex Lighting
20303.0099 PROTECTION GRID ALUMINUM
20303.0100 POLE ADAPTER - DIA. 4060mm PAINTED STEEL
48 - Feam Catalogue 01
REMARK:Due to the development of the national and international specications and of the technology, the above technical characteristicsshowed on this bulletin can be considered as binding on our conrmation only.
Protection grid Pole adapter
CODE DESCRIPTION MATERIAL
-
8/11/2019 01_FEAM_N
49/94YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
EVSNEVSN
Feam Catalogue 01- 49
Ex Lighting
ON REQUEST ACCESSORIES:
Pole mounting kit complete with stainless steel hardware
Ceiling mounting kit complete with stainless steel hardware
Pendant mounting kit complete with stainless steel hardware
Wall/Structure mounting kit complete with stainless steel hardware
Electronic ballast with voltage supply different than standard
Ex-de safety switch
AUTOTEST electronic system for emergency unit
Mechanical characteristics
Body glass bre reinforced polyester resin
Diffuser U/V resistant polycarbonate - hinged to body
Safety closing stainless steel hooks with safety device
Gaskets EPDM 60 rubber suitable for high temperatures and resistant to enviroments conditions
Internal reector white stove enamelled sheet steel
Cable entry complete with PVC cable gland
Electrical characteristics
Power supply dual channel electronic ballast 220/240V 50/60Hz (cos 0,98)
Lampholders bi-pin G13 cap
Terminals suitable up to 6mm/sq cables
Installation: hazardous areas - Zone 2 (Gases) - Zone 22 (Dusts)Classication: Group II - Category 3G 3D
LIGHTING FIXTURES FORFLUORESCENT TUBE LAMPS
LIGHTING FIXTURE EMERGENCY UNIT
ATEX 94/9/EC ATEX 94/9/EC
EXECUTIONII 3 G Ex nA II T6/T5
II 3 D Ex tD A22 T85C/T100C
II 2 G Ex ed IIC
II 2 D Ex tD A21 T85C
AMBIENT TEMPERATURE - -40C +55C
INSTALLATION ZONE 2 - ZONE 22 ZONE 1 / 2 - ZONE 21 / 22
PROTECTION DEGREE IP65 IP66
CERTIFICATE REF. IMQ 08 ATEX 008X IMQ 08 ATEX 026X
RULES OF COMPLIANCE EN 60079-0; EN 60079-15; EN 61241-0; 61241-1 EN 60070-0; EN 60079-7; EN 61241-0; EN 61241-1
-
8/11/2019 01_FEAM_N
50/94
-
8/11/2019 01_FEAM_N
51/94YOUR PARTNER FOR SAFETY
Since 1961
EVSNEVSNE118EL 842 90 120 420 2,75 1 x PG 13,5 B
EVSNE136EL 1451 90 120 775 3,45 1 x PG 13,5 B
EVSNE158EL 1751 90 120 1070 4,10 1 x PG 13,5 B
EVSNE218EL 842 155 120 455 3,10 1 x PG 13,5 B
EVSNE236EL 1451 155 120 770 4,90 1 x PG 13,5 B
EVSNE258EL 1751 155 120 1055 6,20 1 x PG 13,5 B
50
45
100
100
C
BA
D
B
Feam Catalogue 01- 51
Ex Lighting
EVSN Technical features
EVSN Installation and mounting details
CODE A [mm] B [mm] C [mm] D [mm] WEIGHT [Kg] CABLE ENTRY DETAIL
Wall/structure mountingPole mounting
Assemblig detail with pole (typical)
type 3 type 4
type 1 type 2
Ceiling mounting Pendant mounting
Reference details
-
8/11/2019 01_FEAM_N
52/94YOUR PARTNER FOR SAFETY
Since 1961
EVSN
EVS218 EVS236 EVS258
EVS118 EVS136 EVS158
52 - Feam Catalogue 01
Ex Lighting
EVSN Polar diagrams photometric data
EVSN On request accessories
CODE DESCRIPTION INSTALLATION MATERIAL
20302.0122 POLE MOUNTING KIT (SIZE 1 1/2 DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL
20302.0123 POLE MOUNTING KIT (SIZE 2 DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL
20302.0125 POLE MOUNTING KIT (SIZE 1 DIA.) C/W HARDWARE TYPE 4 GALVANIZED STEEL
20301.0165 PENDANT MOUNTING KIT C/W HARDARE A